Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 89
Filtrar
1.
Perioper Med (Lond) ; 13(1): 99, 2024 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-39375742

RESUMO

BACKGROUND: Although pulse oximetry technology, which is considered the standard of care to ensure optimum oxygenation, is indispensable in clinical practice, especially in the detection of hypoxemia, it has some limitations in the detection of hyperoxemia. Oxygen Reserve Index can provide clinicians with a crucial pathway in detecting and preventing hyperoxia, noninvasively. Our aim in this study is to determine the hyperoxia detection ability of ORi and to investigate the effectiveness of ORi and SpO2-guided FiO2 titration in preventing hyperoxia. METHODS: This prospective randomized study was conducted in the operating theater of Health Sciences University Izmir Tepecik Training and Research Hospital from September 1, 2020, to December 1, 2022. Patients undergoing major abdominal surgery were divided into two groups: the control group and the SpO2 + ORi group. FiO2 titration was performed in the SpO2 + ORi group to maintain the ORi between 0.00 and 95% < SpO2 ≤ 98%. Parameters were recorded before induction, 10 min after intubation, and every hour during the operation. RESULTS: A positive linear relationship of 75.8% (r = 0.758) was found between PaO2 and ORi in the ORi + SpO2 group (p < 0.001). Moderate hyperoxemia was observed in 31.6% of patients in the control group, while it was not observed in the ORi + SpO2 group at the 3rd hour. PaO2 values decreased significantly over time in the ORi + SpO2 group with FiO2 titration (p < 0.001). CONCLUSION: The combined use of SpO2 and ORi has been demonstrated to successfully guide FiO2 titration for optimal oxygenation and reduce hyperoxemia.

2.
Indian J Crit Care Med ; 28(8): 803, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39239187

RESUMO

How to cite this article: Mishra S, Kothari N, Sharma A, Goyal S. Author Response: Oxygen Delivery Devices in Postoperative Patients: Proper Selection of Patients Matters! Indian J Crit Care Med 2024;28(8):803.

3.
Br J Anaesth ; 133(2): 424-436, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38816331

RESUMO

BACKGROUND: Postoperative pulmonary complications (PPCs) are associated with postoperative mortality and prolonged hospital stay. Although intraoperative mechanical ventilation (MV) is a risk factor for PPCs, strategies addressing weaning from MV are understudied. In this systematic review, we evaluated weaning strategies and their effects on postoperative pulmonary outcomes. METHODS: Our protocol was registered on PROSPERO (CRD42022379145). Eligible studies included randomised controlled trials and observational studies of adults weaned from MV in the operating room. Primary outcomes included atelectasis and oxygenation; secondary outcomes included lung volume changes and PPCs. Risk of bias was assessed using the Cochrane Risk of Bias (RoB2) tool, and quality of evidence with the GRADE framework. RESULTS: Screening identified 14 randomised controlled trials including 1719 patients; seven studies were limited to the weaning phase and seven included interventions not restricted to the weaning phase. Strategies combining pressure support ventilation (PSV) with positive end-expiratory pressure (PEEP) and low fraction of inspired oxygen (FiO2) improved atelectasis, oxygenation, and lung volumes. Low FiO2 improved atelectasis and oxygenation but might not improve lung volumes. A fixed-PEEP strategy led to no improvement in oxygenation or atelectasis; however, individualised PEEP with low FiO2 improved oxygenation and might be associated with reduced PPCs. Half of included studies are of moderate or high risk of bias; the overall quality of evidence is low. CONCLUSIONS: There is limited research evaluating weaning from intraoperative MV. Based on low-quality evidence, PSV, individualised PEEP, and low FiO2 may be associated with reduced postoperative pulmonary outcomes. SYSTEMATIC REVIEW PROTOCOL: PROSPERO (CRD42022379145).


Assuntos
Salas Cirúrgicas , Desmame do Respirador , Humanos , Desmame do Respirador/métodos , Respiração Artificial/métodos , Complicações Pós-Operatórias/prevenção & controle , Respiração com Pressão Positiva/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto
5.
Pediatr Int ; 66(1): e15753, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38641936

RESUMO

BACKGROUND: This study aimed to assess the validity of the oxygenation saturation index (OSI) and the ratio of oxygen saturation to the fraction of inspired oxygen (FIO2) (S/F ratio) with percutaneous oxygen saturation (OSISpO2 and the Sp/F ratio) and to evaluate the correlation between these values and the oxygen index (OI). It also determined their cut-off values for predicting OI in accordance with neonatal hypoxic respiratory failure severity. METHODS: We reviewed the data of 77 neonates (gestational age 31.7 ± 6.1 weeks; birthweight, 1768 ± 983 g) requiring invasive mechanical ventilation between 2013 and 2020, 1233 arterial blood gas samples in total. We calculated the OI, OSISpO2, OSI with arterial oxygen saturation (SaO2) (OSISaO2), Sp/F ratio, and the ratio of SaO2 to FIO2 (Sa/F ratio). RESULTS: The regression and Bland-Altman analysis showed good agreement between OSISpO2 or the Sp/F ratio and OSISaO2 or the Sa/F ratio. Although a significant positive correlation was found between OSISpO2 and OI, OSISpO2 was overestimated in SpO2 > 98% with a higher slope of the fitted regression line than that below 98% of SpO2. Furthermore, receiver-operating characteristic curve analysis using only SpO2 ≤ 98% samples showed that the optimal cut-off points of OSISpO2 and the Sp/F ratio for predicting OI were: OI 5, 3.0 and 332; OI 10, 5.3 and 231; OI 15, 7.7 and 108; OI 20, 11.0 and 149; and OI 25, 17.1 and 103, respectively. CONCLUSION: The cut-off OSISpO2 and Sp/F ratio values could allow continuous monitoring for oxygenation changes in neonates with the potential for wider clinical applications.


Assuntos
Doenças do Recém-Nascido , Insuficiência Respiratória , Humanos , Recém-Nascido , Gasometria , Hipóxia/diagnóstico , Oximetria , Oxigênio , Insuficiência Respiratória/diagnóstico , Insuficiência Respiratória/terapia
6.
Respir Care ; 69(4): 438-448, 2024 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-38443141

RESUMO

BACKGROUND: The nasal cannula is widely regarded as a safe and effective means of administering low- and high-flow oxygen to patients irrespective of their age. However, variability in delivered oxygen concentration (FDO2 FDO2 ) via nasal cannula has the potential to pose health risks. The present study aimed to evaluate predictive equations for FDO2 over a large parameter space, including variation in breathing, oxygen flow, and upper-airway geometry representative of both young children and adults. METHODS: Realistic nasal airway geometries were previously collected from medical scans of adults, infants, and neonates. Nasal airway replicas based on these geometries were used to measure the FDO2 for low-flow oxygen delivery during simulated spontaneous breathing. The present study extends previously published data sets to include higher oxygen flows. The extended data sets included nasal cannula oxygen flows that ranged from 6 to 65 L/min for the adult replicas, and from 0.5 to 6 L/min for the infant replicas. For both age groups, FDO2 was measured over a range of breathing frequencies, inspiratory to expiratory time ratios, and tidal volumes. Measured FDO2 values were compared with values predicted by using a previously derived flow-weighted equation. RESULTS: For both age groups, FDO2 was observed to increase nonlinearly with the ratio between oxygen flow supplied to the nasal cannula and the average inhalation flow. The previously derived flow-weighted equation over-predicted FDO2 at higher oxygen flows. A new empirical equation, therefore, was proposed to predict FDO2 for either age group as a function of nasal cannula flow, tidal volume, and inspiratory time. Predicted FDO2 values matched measured values, with average relative errors of 2.4% for infants and 4.3% for adults. CONCLUSIONS: A new predictive equation for FDO2 was obtained that accurately matched measured data in both adult and infant airway replicas for low- and high-flow regimens.


Assuntos
Cânula , Respiração , Recém-Nascido , Adulto , Lactente , Criança , Humanos , Pré-Escolar , Nariz , Oxigênio , Intubação , Oxigenoterapia
7.
Indian J Crit Care Med ; 28(3): 251-255, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38476998

RESUMO

Background: Intensive care unit (ICU) patients face a significant rise in mortality rates due to acute hypoxemic respiratory failure (AHRF). The diagnosis of AHRF is based on the PF ratio, but it has limitations in resource-constrained settings. Instead, the Kigali modification suggests using the oxygen saturation/fraction of inspired oxygen (SF) ratio. This study aims to correlate SF ratio and arterial oxygen pressure (PF) ratio in critically ill adults with hypoxemic respiratory failure, who required O2 therapy through different modes of oxygen supplementation. Materials and methods: In an ICU, a prospective observational study included 125 adult AHRF patients receiving oxygen therapy, with data collected on FiO2, PaO2, and SpO2. The SF ratio and PF ratio were calculated, and their correlation was assessed using statistical analysis. The receiver operator characteristics (ROC) curve analysis was conducted to assess the diagnostic precision of the SF ratio in identifying AHRF. Results: Data from a total of 250 samples were collected. The study showed a positive correlation (r = 0.622) between the SF ratio and the PF ratio. The SF threshold values of 252 and 321 were established for PF values of 200 and 300, respectively, featuring a sensitivity of 69% and specificity of 95%. Furthermore, it is worth noting that the PF ratio and SF ratio are interchangeable, regardless of the type of oxygen therapy, as the median values of both the PF ratio and SF ratio displayed statistical significance (p < 0.01) in both acidosis and alkalosis conditions. Conclusion: For patients with AHRF, the noninvasive SF ratio can effectively serve as a substitute for the invasive PF ratio across all oxygen supplementation modes. How to cite this article: Alur TR, Iyer SS, Shah JN, Kulkarni S, Jedge P, Patil V. A Prospective Observational Study Comparing Oxygen Saturation/Fraction of Inspired Oxygen Ratio with Partial Pressure of Oxygen in Arterial Blood/Fraction of Inspired Oxygen Ratio among Critically Ill Patients Requiring Different Modes of Oxygen Supplementation in Intensive Care Unit. Indian J Crit Care Med 2024; 28(3):251-255.

8.
J Clin Monit Comput ; 37(6): 1489-1495, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37828296

RESUMO

SentriO Oxy™ is a newly available, Food and Drug Administration-approved oxygenation mask system that provides high oxygenation, even on low-flow (5-10 L/min) oxygen. This study aimed to accurately measure the intratracheal fraction of inspired oxygen (FiO2) using SentriO Oxy™ masks under relatively low oxygen flow rates. A manikin-ventilator-test lung simulation system was used. We measured FiO2 at the level of the carina, 5 minutes after applying 45 different respiratory parameter combinations using SentriO Oxy™ masks. Tidal volume (TV) was set to 300, 500, and 700 mL; respiratory rate (RR) was set to 8, 12, 16, 20, and 24 breaths per minute; and oxygen flow rate was set to 6, 8, and 10 L/min. Our hypothesis was that FiO2 would be proportional to the difference between oxygen flow rate and minute ventilation. FiO2 measured by smaller TV, lower RR, or higher oxygen flows revealed a significantly higher value, confirming our hypothesis. In addition, using linear regression analysis, we found that TV, RR, and oxygen flow were all significant factors influencing the measured FiO2. Our experiment proposed two prediction equations considering the oxygen flow rate, TV, and RR. The results of our study may provide information and prediction of FiO2 for clinicians to use SentriO Oxy™ masks during sedative anesthetic procedures under low oxygen flow rates.


Assuntos
Máscaras , Taxa Respiratória , Humanos , Ventiladores Mecânicos , Volume de Ventilação Pulmonar , Oxigênio , Oxigenoterapia
9.
Eur J Pediatr ; 182(12): 5399-5407, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37750912

RESUMO

To determine the early factors associated with continuous positive airway pressure (CPAP) failure in moderate-to-late preterm infants (32 + 0/7 to 36 + 6/7 weeks' gestation) from the NEOBS cohort study. The NEOBS study was a multi-center, prospective, observational study in 46 neonatal intensive care units in France, which included preterm and late preterm infants with early neonatal respiratory distress. This analysis included a subset of the NEOBS population who had respiratory distress and required ventilatory support with CPAP within the first 24 h of life. CPAP failure was defined as the need for tracheal intubation within 72 h of CPAP initiation. Maternal and neonatal clinical parameters in the delivery room and clinical data at 3 h of life were analyzed. CPAP failure occurred in 45/375 infants (12%), and compared with infants with CPAP success, they were mostly singletons (82.2% vs. 62.1%; p < 0.01), had a lower Apgar score at 10 min of life (9.1 ± 1.3 vs. 9.6 ± 0.8; p = 0.02), and required a higher fraction of inspired oxygen (FiO2; 34.4 ± 15.9% vs. 22.8 ± 4.1%; p < 0.0001) and a higher FiO2*positive end-expiratory pressure (PEEP) (1.8 ± 0.9 vs. 1.1 ± 0.3; p < 0.0001) at 3 h. FiO2 value of 0.23 (R2 = 0.73) and FiO2*PEEP of 1.50 (R2 = 0.75) best predicted CPAP failure. The risk of respiratory distress and early CPAP failure decreased 0.7 times per 1-week increase in gestational age and increased 1.7 times with every one-point decrease in Apgar score at 10 min and 19 times with FiO2*PEEP > 1.50 (vs. ≤ 1.50) at 3 h (R2 of the overall model = 0.83).  Conclusion: In moderate-to-late preterm infants, the combination of singleton pregnancy, lower Apgar score at 10 min, and FiO2*PEEP > 1.50 at 3 h can predict early CPAP failure with increased accuracy. What is Known: •Respiratory distress syndrome (RSD) represents an unmet medical need in moderate-to-late preterm births and is commonly treated with continuous positive airway pressure (CPAP) to reduce mortality and the need for additional ventilatory support. • Optimal management of RSD is yet to be established, with several studies suggesting that identification of predictive factors for CPAP failure can aid in the prompt treatment of infants likely to experience this failure. What is New: •Secondary analysis of the observational NEOBS study indicated that oxygen requirements during CPAP therapy, especially the product of fraction of inspired oxygen (FiO2) and positive end-expiratory pressure (PEEP), are important factors associated with early CPAP failure in moderate-to-late term preterm infants. •The combination of a singleton pregnancy, low Apgar score at 10 minutes, and high FiO2*PEEP at 3 hours can predict early CPAP failure with increased accuracy, highlighting important areas for future research into the prevention of CPAP failure.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Síndrome do Desconforto Respiratório do Recém-Nascido , Lactente , Recém-Nascido , Humanos , Recém-Nascido Prematuro , Estudos Prospectivos , Estudos de Coortes , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Oxigênio
10.
BJA Open ; 7: 100207, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37655933

RESUMO

Background: This study assessed the potential cost-effectiveness of high (80-100%) vs low (21-35%) fraction of inspired oxygen (FiO2) at preventing surgical site infections (SSIs) after abdominal surgery in Nigeria, India, and South Africa. Methods: Decision-analytic models were constructed using best available evidence sourced from unbundled data of an ongoing pilot trial assessing the effectiveness of high FiO2, published literature, and a cost survey in Nigeria, India, and South Africa. Effectiveness was measured as percentage of SSIs at 30 days after surgery, a healthcare perspective was adopted, and costs were reported in US dollars ($). Results: High FiO2 may be cost-effective (cheaper and effective). In Nigeria, the average cost for high FiO2 was $216 compared with $222 for low FiO2 leading to a -$6 (95% confidence interval [CI]: -$13 to -$1) difference in costs. In India, the average cost for high FiO2 was $184 compared with $195 for low FiO2 leading to a -$11 (95% CI: -$15 to -$6) difference in costs. In South Africa, the average cost for high FiO2 was $1164 compared with $1257 for low FiO2 leading to a -$93 (95% CI: -$132 to -$65) difference in costs. The high FiO2 arm had few SSIs, 7.33% compared with 8.38% for low FiO2, leading to a -1.05 (95% CI: -1.14 to -0.90) percentage point reduction in SSIs. Conclusion: High FiO2 could be cost-effective at preventing SSIs in the three countries but further data from large clinical trials are required to confirm this.

11.
BMC Anesthesiol ; 23(1): 265, 2023 08 08.
Artigo em Inglês | MEDLINE | ID: mdl-37550648

RESUMO

BACKGROUND: There is the ongoing debate over the effect of inspired oxygen fraction (FiO2) during mechanical ventilation on postoperative atelectasis. We aimed to compare the effects of low (30%) and moderate (60%) FiO2 on postoperative atelectasis. The hypothesis of the study was that 30% FiO2 during mechanical ventilation could reduce postoperative atelectasis volume compared with 60% FiO2. METHODS: We performed a randomized controlled trial with 120 patients. Subjects were randomly assigned to receive 30% or 60% FiO2 during mechanical ventilation in a 1:1 ratio. The primary outcome was the percentage of postoperative atelectasis volume in the total lung measured using chest CT within 30 min after extubation. The secondary outcomes included different aeration region volumes, incidence of clinically significant atelectasis, and oxygenation index. RESULTS: In total, 113 subjects completed the trial, including 55 and 58 subjects in the 30% and 60% FiO2 groups, respectively. The percentage of the postoperative atelectasis volume in the 30% FiO2 group did not differ from that in the 60% FiO2 group. Furthermore, there was no significant difference in the atelectasis volume between the two groups after the missing data were imputed by multiple imputation. Additionally, there were no significant differences in the volumes of the over-aeration, normal-aeration, and poor-aeration regions between the groups. No significant differences in the incidence of clinically significant atelectasis or oxygenation index at the end of surgery were observed between the groups. CONCLUSIONS: Compared with 60% FiO2, the use of 30% FiO2 during mechanical ventilation does not reduce the postoperative atelectasis volume. TRIAL REGISTRATION: Chinese Clinical Trial Registry ( http://www.chictr.org.cn ). Identifier: ChiCTR1900021635. Date: 2 March 2019. Principal invetigator: Weidong Gu.


Assuntos
Atelectasia Pulmonar , Respiração Artificial , Humanos , Respiração Artificial/efeitos adversos , Oxigênio , Atelectasia Pulmonar/prevenção & controle , Atelectasia Pulmonar/etiologia , Pulmão , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/etiologia
12.
J Intensive Med ; 2023 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-37362867

RESUMO

Determining oxygenation targets in acute respiratory distress syndrome (ARDS) remains a challenge. Although oxygenation targets have been used since ARDS was first described, they have not been investigated in detail. However, recent retrospective and prospective trials have evaluated the optimal oxygenation threshold in patients admitted to the general intensive care unit. In view of the lack of prospective data, clinicians continue to rely on data from the few available trials to identify the optimal oxygenation strategy. Assessment of the cost-benefit ratio of the fraction of inspired oxygen (FiO2) to the partial pressure of oxygen in the arterial blood (PaO2) is an additional challenge. A high FiO2 has been found to be responsible for respiratory failure and deaths in numerous animal models. Low and high PaO2 values have also been demonstrated to be potential risk factors in experimental and clinical situations. The findings from this literature review suggest that PaO2 values ranging between 80 mmHg and 90 mmHg are acceptable in patients with ARDS. The costs of rescue maneuvers needed to reach these targets have been discussed. Several recent papers have highlighted the risk of disagreement between arterial oxygen saturation (SaO2) and peripheral oxygen saturation (SpO2) values. In order to avoid discrepancies and hidden hypoxemia, SpO2 readings need to be compared with those of SaO2. Higher SpO2 values may be needed to achieve the recommended PaO2 and SaO2 values.

13.
Med Intensiva ; 47(3): 131-139, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36855737

RESUMO

Objective: Few studies have reported the implications and adverse events of performing endotracheal intubation for critically ill COVID-19 patients admitted to intensive care units. The aim of the present study was to determine the adverse events related to tracheal intubation in COVID-19 patients, defined as the onset of hemodynamic instability, severe hypoxemia, and cardiac arrest. Setting: Tertiary care medical hospitals, dual-centre study performed in Northern Italy from November 2020 to May 2021. Patients: Adult patients with positive SARS-CoV-2 PCR test, admitted for respiratory failure and need of advanced invasive airways management. Interventions: Endotracheal Intubation Adverse Events. Main variables of interests: The primary endpoint was to determine the occurrence of at least 1 of the following events within 30 minutes from the start of the intubation procedure and to describe the types of major adverse peri-intubation events: severe hypoxemia defined as an oxygen saturation as measured by pulse-oximetry <80%; hemodynamic instability defined as a SBP 65 mmHg recoded at least once or SBP < 90 mmHg for 30 minutes, a new requirement or increase of vasopressors, fluid bolus >15 mL/kg to maintain the target blood pressure; cardiac arrest. Results: Among 142 patients, 73.94% experienced at least one major adverse peri-intubation event. The predominant event was cardiovascular instability, observed in 65.49% of all patients undergoing emergency intubation, followed by severe hypoxemia (43.54%). 2.82% of the patients had a cardiac arrest. Conclusion: In this study of intubation practices in critically ill patients with COVID-19, major adverse peri-intubation events were frequent. Clinical Trial registration: www.clinicaltrials.gov identifier: NCT04909476.


Objetivo: Pocos estudios han informado las implicaciones y los eventos adversos de realizar una intubación endotraqueal para pacientes críticos con COVID-19 ingresados ​​en unidades de cuidados intensivos. El objetivo del presente estudio fue determinar los eventos adversos relacionados con la intubación traqueal en pacientes con COVID-19, definidos como la aparición de inestabilidad hemodinámica, hipoxemia severa y paro cardíaco. Ámbito: Hospitales médicos de atención terciaria, estudio de doble centro realizado en el norte de Italia desde noviembre de 2020 hasta mayo de 2021. Pacientes: Pacientes adultos con prueba PCR SARS-CoV-2 positiva, ingresados por insuficiencia respiratoria y necesidad de manejo avanzado de vías aéreas invasivas. Intervenciones: Eventos adversos de la intubación endotraqueal. Principales variables de interés: El punto final primario fue determinar la ocurrencia de al menos 1 de los siguientes eventos dentro de los 30 minutos posteriores al inicio del procedimiento de intubación y describir los tipos de eventos adversos periintubación mayores. : hipoxemia severa definida como una saturación de oxígeno medida por pulsioximetría <80%; inestabilidad hemodinámica definida como PAS 65 mmHg registrada al menos una vez o PAS < 90 mmHg durante 30 minutos, nuevo requerimiento o aumento de vasopresores, bolo de líquidos > 15 mL/kg para mantener la presión arterial objetivo; paro cardiaco. Resultados: Entre 142 pacientes, el 73,94% experimentó al menos un evento periintubación adverso importante. El evento predominante fue la inestabilidad cardiovascular, observada en el 65,49% de todos los pacientes sometidos a intubación de urgencia, seguido de la hipoxemia severa (43,54%). El 2,82% de los pacientes tuvo un paro cardíaco. Conclusión: En este estudio de prácticas de intubación en pacientes críticos con COVID-19, los eventos adversos periintubación mayores fueron frecuentes. Registro de ensayos clínicos: www.clinicaltrials.gov identificador: NCT04909476.

14.
J Intensive Med ; 3(1): 73-78, 2023 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-36789362

RESUMO

Background: To investigate the relationship between partial pressure of oxygen (PaO2)/fraction of inspired oxygen (FiO2) and the probability of delirium in intensive care units (ICUs). Methods: The investigation was a cross-sectional study that involved the collection of data from patients admitted to the Xiang Ya Hospital Cardiothoracic Surgical Care Unit and Comprehensive Intensive Care Unit from 01 September 2016 to 10 December 2016. Delirium was diagnosed using the simplified version of the Chinese Confusion Assessment Method (CAM) for the ICU. Demographic and medical data were obtained within 24 h of each patient admitted in the ICU. The PaO2/FiO2 of each patient was recorded 24 h after admission in the ICU. The patients were divided into three groups according to PaO2/FiO2 data : normal (PaO2/FiO2 ≥300 mmHg), slightly low (200 ≥PaO2/FiO2 <300 mmHg), and severely low (PaO2/FiO2 <200 mmHg). Baseline characteristics were compared in the three groups. Results of the unadjusted model, minimally adjusted model, and fully adjusted model are presented. Results: A total of 403 participants were included in the study, of which 184 (45.7%) developed delirium. Age (P <0.001), Sequential Organ Failure Assessment (SOFA) score (P <0.001), Acute Physiology and Chronic Health Evaluation (APACHE) II score (P <0.001), mechanical ventilation time (P <0.001), history of hypertension (P=0.040), heart disease (P=0.040), sedation (P=0.001), and PaO2/FiO2 (P=0.006) were significantly associated with delirium in univariate analysis. Multivariate regression analysis models were used to further analyze the associations between PaO2/FiO2 and delirium. In the crude model, for 1 standard deviation (SD) increase in PaO2/FiO2, the odds ratio (OR) of delirium was 0.8 (95% confidence interval [CI]: 0.6-0.9), but there was no significant correlation in the fully adjusted model. There was a non-linear relationship between the PaO2/FiO2 and delirium in a generalized additive model. A two-piecewise linear regression model was used to calculate a PaO2/FiO2 threshold of 243 mmHg. On the left side of the threshold, the OR was 0.9 and the 95% CI was 0.9-1.0 (P=0.013) when PaO2/FiO2 increased by 1 SD. Conclusions: PaO2/FiO2 was negatively associated with delirium when PaO2/FiO2 was below the identified threshold. As a readily available laboratory indicator, PaO2/FiO2 has potential value in the clinical evaluation of risk of delirium in ICU patients.

16.
Respir Res ; 23(1): 333, 2022 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-36482438

RESUMO

BACKGROUND: The nasal cannula is considered a trusted and effective means of administering low-flow oxygen and is widely used for neonates and infants requiring oxygen therapy, despite an understanding that oxygen concentrations delivered to patients are variable. METHODS: In the present study, realistic nasal airway replicas derived from medical scans of children less than 3 months old were used to measure the fraction of oxygen inhaled (FiO2) through nasal cannulas during low-flow oxygen delivery. Parameters influencing variability in FiO2 were evaluated, as was the hypothesis that measured FiO2 values could be predicted using a simple, flow-weighted calculation that assumes ideal mixing of oxygen with entrained room air. Tidal breathing through neonatal and infant nasal airway replicas was controlled using a lung simulator. Parameters for nasal cannula oxygen flow rate, nasal airway geometry, tidal volume, respiratory rate, inhalation/exhalation, or I:E ratio (ti/te), breath waveform, and cannula prong insertion position were varied to determine their effect on measured FiO2. In total, FiO2 was measured for 384 different parameter combinations, with each combination repeated in triplicate. Analysis of variance (ANOVA) was used to assess the influence of parameters on measured FiO2. RESULTS: Measured FiO2 was not appreciably affected by the breath waveform shape, the replica geometry, or the cannula position but was significantly influenced by the tidal volume, the inhalation time, and the nasal cannula flow rate. CONCLUSIONS: The flow-weighted calculation overpredicted FiO2 for measured values above 60%, but an empirical correction to the calculation provided good agreement with measured FiO2 across the full range of experimental data.


Assuntos
Cânula , Oxigênio , Criança , Recém-Nascido , Humanos , Lactente
17.
Front Med (Lausanne) ; 9: 1001979, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36213639

RESUMO

Background: Despite patients with severe coronavirus disease (COVID-19) receiving standard triple therapy, including steroids, antiviral agents, and anticytokine therapy, health condition of certain patients continue to deteriorate. In Taiwan, the COVID-19 mortality has been high since the emergence of previous variants of this disease (such as alpha, beta, or delta). We aimed to evaluate whether adjunctive infusion of human umbilical cord mesenchymal stem cells (MSCs) (hUC-MSCs) on top of dexamethasone, remdesivir, and tocilizumab improves pulmonary oxygenation and suppresses inflammatory cytokines in patients with severe COVID-19. Methods: Hospitalized patients with severe or critical COVID-19 pneumonia under standard triple therapy were separated into adjuvant hUC-MSC and non-hUC-MSC groups to compare the changes in the arterial partial pressure of oxygen (PaO2)/fraction of inspired oxygen (FiO2) ratio and biological variables. Results: Four out of eight patients with severe or critical COVID-19 received either one (n = 2) or two (n = 2) doses of intravenous infusions of hUC-MSCs using a uniform cell dose of 1.0 × 108. Both high-sensitivity C-reactive protein (hs-CRP) level and monocyte distribution width (MDW) were significantly reduced, with a reduction in the levels of interleukin (IL)-6, IL-13, IL-12p70 and vascular endothelial growth factor following hUC-MSC transplantation. The PaO2/FiO2 ratio increased from 83.68 (64.34-126.75) to 227.50 (185.25-237.50) and then 349.56 (293.03-367.92) within 7 days after hUC-MSC infusion (P < 0.001), while the change of PaO2/FiO2 ratio was insignificant in non-hUC-MSC patients (admission day: 165.00 [102.50-237.61]; day 3: 100.00 [72.00-232.68]; day 7: 250.00 [71.00-251.43], P = 0.923). Conclusion: Transplantation of hUC-MSCs as adjunctive therapy improves pulmonary oxygenation in patients with severe or critical COVID-19. The beneficial effects of hUC-MSCs were presumably mediated by the mitigation of inflammatory cytokines, characterized by the reduction in both hs-CRP and MDW.

18.
Cureus ; 14(5): e25122, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35733468

RESUMO

PURPOSE: The fraction of inspired oxygen while administering oxygen to patients must be measured as it represents the alveolar oxygen concentration, which is important from a respiratory physiology viewpoint. Therefore, the purpose of this study was to compare the fractions of inspired oxygen obtained through different oxygen delivery devices. METHODS: A simulation model of spontaneous respiration was used. The fractions of inspired oxygen obtained through low- and high-flow nasal cannulas and a simple oxygen mask were measured. The fraction of inspired air was measured every second for 30 s after 120 s of oxygen administration. This was measured three times under each condition. RESULTS: With a low-flow nasal cannula, airflow reduced both the intratracheal fraction of inspired oxygen and extraoral oxygen concentration, indicating that exhalatory respiration occurred during rebreathing and may be involved in increasing the intratracheal fraction of inspired oxygen. CONCLUSION: Oxygen administration during expiratory flow may lead to an increased oxygen concentration in the anatomical dead space, which may be involved in the increase in the fraction of inspired oxygen. With a high-flow nasal cannula, a high fraction of inspired oxygen can be achieved even at a flow rate of 10 L/min. When determining the optimum amount of oxygen, it is necessary to set an appropriate flow rate for patients and specific conditions without being bound by the fraction of inspired oxygen values alone. It might be difficult to estimate the fraction of inspired oxygen while using a low-flow nasal cannula and simple oxygen mask in clinical situations.

19.
J Anesth ; 36(5): 633-641, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35711009

RESUMO

PURPOSE: We investigated the impact of surgical masks (SM) during oxygen therapy using oxygen masks in volunteer- and simulation-based studies. METHODS: Fifteen volunteers wore the Hudson RCI® or Open-Face Mask® with/without an SM. The fraction of inspired oxygen concentration (FIO2), end-tidal CO2 (EtCO2), partial pressure of inspired CO2 (PICO2), and respiratory rate (RR) were measured. The oxygen flow rate increased from 0 to 10 L/min. In the simulation-based study, FIO2 was measured using a simulator that reproduced spontaneous breathing. RR was 12 or 24 bpm, and the tidal volume (Tv) was 300, 500, or 700 mL. The effect of oxygen mask fitting conditions was also examined. The primary outcome measure was FIO2 at 6 L/min. RESULTS: In the volunteer-based study, FIO2 was reduced when the SM was used with the Hudson RCI® or Open-Face Mask®. The FIO2 drop was larger with the Open-Face Mask® than with the Hudson RCI®. The RR, EtCO2, and PICO2 significantly changed with the SM, but the differences were not clinically meaningful. In the simulation-based study, the SM with the Hudson RCI® did not reduce FIO2, but the SM with the Open-Face Mask® significantly decreased FIO2 under several conditions. However, the SM with the Hudson Mask® reduced FIO2 when the fit of the mask was inadequate. With the Open-Face Mask®, lower RR and Tv resulted in larger differences in FIO2. CONCLUSIONS: The SM decreased FIO2 during oxygen therapy with oxygen masks. The impact of SM depended on the type of the oxygen mask, mask fitting, and respiratory condition.


Assuntos
Máscaras , Oxigênio , Dióxido de Carbono , Humanos , Oxigenoterapia/métodos , Taxa Respiratória , Voluntários
20.
Acta Anaesthesiol Scand ; 66(8): 923-933, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35675085

RESUMO

BACKGROUND: Controversy exists regarding the effects of a high versus a low intraoperative fraction of inspired oxygen (FiO2 ) in adults undergoing general anesthesia. This systematic review and meta-analysis investigated the effect of a high versus a low FiO2 on postoperative outcomes. METHODS: PubMed and Embase were searched on March 22, 2022 for randomized clinical trials investigating the effect of different FiO2 levels in adults undergoing general anesthesia for non-cardiac surgery. Two investigators independently reviewed studies for relevance, extracted data, and assessed risk of bias. Meta-analyses were performed for relevant outcomes, and potential effect measure modification was assessed in subgroup analyses and meta-regression. The evidence certainty was evaluated using GRADE. RESULTS: This review included 25 original trials investigating the effect of a high (mostly 80%) versus a low (mostly 30%) FiO2 . Risk of bias was intermediate for all trials. A high FiO2 did not result in a significant reduction in surgical site infections (OR: 0.91, 95% CI 0.81-1.02 [p = .10]). No effect was found for all other included outcomes, including mortality (OR = 1.27, 95% CI: 0.90-1.79 [p = .18]) and hospital length of stay (mean difference = 0.03 days, 95% CI -0.25 to 0.30 [p = .84). Results from subgroup analyses and meta-regression did not identify any clear effect modifiers across outcomes. The certainty of evidence (GRADE) was rated as low for most outcomes. CONCLUSIONS: In adults undergoing general anesthesia for non-cardiac surgery, a high FiO2 did not improve outcomes including surgical site infections, length of stay, or mortality. However, the certainty of the evidence was assessed as low.


Assuntos
Oxigênio , Infecção da Ferida Cirúrgica , Adulto , Anestesia Geral , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA