Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.567
Filtrar
1.
Front Surg ; 11: 1430100, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39011052

RESUMO

For early-stage non-small cell lung cancer, surgical resection remains the best treatment option. Currently, sublobar resection, including segmentectomy, is recommended in these cases, as it provides a better quality of life with the same oncological outcomes; however, is requires adequate resection margins. Accurate preoperative planning and proper identification of the intersegmental planes during thoracic surgery are crucial for ensuring precise surgical management and adequate resection margins. Three dimensional computed tomography reconstruction and near-infrared-guided intersegmental plane identification can greatly facilitate the surgical procedures. Three-dimensional computed tomography reconstruction can simulate both the resection and resection margins. Indocyanine green is one of the most frequently used and affordable fluorophores. There are two ways to identify the intersegmental planes using indocyanine green: intravenous and transbronchial administration. Intravenous application is simple; however, its effectiveness may be affected by underlying lung disease, and it requires the isolation of segmental structures before administration. Transbronchial use requires appropriate bronchoscopic skills and preoperative planning; however, it also allows for delineation deep in the parenchyma and can be used for complex segmentectomies. Both methods can be used to ensure adequate resection margins and, therefore, achieve the correct oncological radicality of the surgical procedure. Here, we summarise these applications and provide an overview of their different possibilities.

2.
Artigo em Inglês | MEDLINE | ID: mdl-39013712

RESUMO

The objective of this review was to conduct a systematic review and meta-analysis on the efficacy of ICG (indocyanine green) for sentinel lymph node (SLN) detection in head and neck melanoma. The Preferred Reporting Items for Systematic reviews and Meta-Analyses statement standards (PRISMA) were followed when conducting this review with a comprehensive search of the following online databases; Google Scholar, PubMed, MEDLINE, CINAHL, and CENTRAL, World Health Organization International Clinical Trials Registry (http://apps.who.int/trialsearch/), ClinicalTrials.gov (http://clinical-trials.gov/), and the ISRCTN registry (http://www.isrctn.com/). Nine studies met the inclusion criteria and results were reported with forest plots at 95% confidence intervals. Primary outcomes of interest included the localisation rate for sentinel node biopsies in head and neck melanoma using ICG and its compared with other adjunct modalities. Secondary outcome measures included false negative rates as well as sensitivity rates for nodal detection with radiocolloid as well as blue dye. ICG reported an overall sensitivity rate of 95% with an untransformed proportion metric analysis (0.950, 0.922, 0.978 (95% CI)). It demonstrated a superior detection rate to blue dye (Odds ratio 15.417, 95% CI, 4.652 to 51.091, p < 0.001) and a comparable localisation efficacy to radiocolloid (Odds ratio 1.425, 95% CI, 0.535 to 3.794, p = 0.478). The sensitivity rate for radiocolloid utilisation in isolation was 90.6% (untransformed proportion metric, 0.906, 0.855, 0.957) and blue dye was 48.7% (untransformed proportion metric, 0.487, 0.364, 0.610). This is the first meta-analysis on the efficacy of ICG for sentinel node detection in head and neck melanoma. The authors advocate for a dual modality approach with ICG and radiocolloid to mitigate the inherent limitations of both methods when conducting sentinel node retrieval for head and neck melanoma. Further high-quality randomised trials are needed to improve the current evidence base.

3.
Gland Surg ; 13(6): 1031-1044, 2024 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-39015719

RESUMO

Background: Fluorescence-guided surgery (FGS) is a cutting-edge technology that uses near-infrared (NIR) fluorescence imaging to guide surgeons in surgery. Indocyanine green (ICG) is a fluorescent dye, which can be used for in vivo imaging of tumor cells. We aimed to explore the use of ICG fluorescence-guided technology as a rapid intraoperative margin assessment method for breast cancer surgery. In addition, we also compared the dose selection of ICG. Methods: This was a non-randomized prospective cohort study. Data were collected between August 2021 and October 2022 in the Division of Breast Surgery, Department of General Surgery, Nanjing Drum Tower Hospital, the Affiliated Hospital of Medical School, Nanjing University. Upon specimen removal, tumor margins were immediately analyzed by ICG fluorescence detection and then sent to the pathology department for intraoperative frozen section analysis and subsequent routine pathological examination. Abnormal margin rates were calculated and compared using intraoperative frozen section analysis and under the guidance of ICG fluorescence. Results: The study included 69 cases of breast cancer patients who underwent tumor resection assisted by ICG fluorescence-guided technology, including 18 patients with a 0.5 mg/kg dose and 51 patients with a 1.0 mg/kg dose. According to the study findings, the ICG test achieved a sensitivity of 81.82% and a specificity of 75.82%. At a dose of 0.5 mg/kg, the sensitivity was 66.67% whereas the specificity was 93.33%. At the dose of 1 mg/kg, the sensitivity was 87.5%, and the specificity was 74.42%. Similarly, for intraoperative frozen section analysis, the sensitivity was 81.82%, but the specificity was enhanced to 94.83%. Positive surgical cut margin was not identified in 2/69 by ICG fluorescence and frozen section analysis respectively. Conclusions: The sensitivity of ICG fluorescence detection is comparable to that of frozen section analysis, but the specificity is poor. The sensitivity increased and the specificity decreased at 1 mg/kg compared to the 0.5 mg/kg dose. ICG fluorescence can be used as a supplementary tool for frozen section analysis. These findings support further development and clinical performance assessment of ICG fluorescence.

4.
Tech Coloproctol ; 28(1): 83, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38985353

RESUMO

BACKGROUND: Ureteric injury (UI) is an infrequent but serious complication of colorectal surgery. Prophylactic ureteric stenting is employed to avoid UI, yet its efficacy remains debated. Intraoperative indocyanine green fluorescence imaging (ICG-FI) has been used to facilitate ureter detection. This study aimed to investigate the role of ICG-FI in identification of ureters during colorectal surgery and its impact on the incidence of UI. METHODS: A retrospective cohort study involving 556 consecutive patients who underwent colorectal surgery between 2018 and 2023 assessed the utility of routine prophylactic ureteric stenting with adjunctive ICG-FI. Patients with ICG-FI were compared to those without ICG-FI. Demographic data, operative details, and postoperative morbidity were analyzed. Statistical analysis included univariable regression. RESULTS: Ureteric ICG-FI was used in 312 (56.1%) patients, whereas 43.9% were controls. Both groups were comparable in terms of demographics except for a higher prevalence of prior abdominal surgeries in the ICG-FI group. Although intraoperative visualization was significantly higher in the ICG-FI group (95.3% vs 89.1%; p = 0.011), the incidence of UI was similar between groups (0.3% vs 0.8%; p = 0.585). Postoperative complications were similar between the two groups. Median stent insertion time was longer in the ICG-FI group (32 vs 25 min; p = 0.001). CONCLUSION: Ureteric ICG-FI improved intraoperative visualization of the ureters but was not associated with a reduced UI rate. Median stent insertion time increased with use of ureteric ICG-FI, but total operative time did not. Despite its limitations, this study is the largest of its kind suggesting that ureteric ICG-FI may be a valuable adjunct to facilitate  ureteric visualization during colorectal surgery.


Assuntos
Verde de Indocianina , Imagem Óptica , Stents , Ureter , Humanos , Estudos Retrospectivos , Feminino , Masculino , Ureter/lesões , Ureter/cirurgia , Pessoa de Meia-Idade , Idoso , Imagem Óptica/métodos , Cirurgia Colorretal/efeitos adversos , Cirurgia Colorretal/métodos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/epidemiologia , Corantes , Complicações Intraoperatórias/prevenção & controle , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/epidemiologia , Incidência , Adulto
5.
Bioorg Med Chem ; 110: 117824, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38981218

RESUMO

Fluorescence lymph imaging with indocyanine green (ICG) is widely utilized as diagnostic tool for lymphatic diseases. While this technique offers numerous advantages, the kinetics of ICG at the injection site can pose challenges for a detailed diagnosis. In this study, we synthesized various ICG derivatives possessing cationic, anionic, or uncharged substituents and examined their photochemical properties, binding affinity to human serum albumin, as well as their correlation to pharmacokinetics in mice. The introduction of different substituents not only affected certain physiochemical properties, but also impacted the pharmacokinetics within the lymph nodes. Immunofluorescence imaging suggested that the extent of uptake of the ICG derivatives by phagocytic cells may affect the retention of the contrast ratios in the lymph nodes. These findings can provide new insights in the pharmacokinetics in lymphatic tissues, which could be useful for the development of novel fluorescent agents for lymph imaging.

6.
Int J Surg Case Rep ; 121: 110014, 2024 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-38981297

RESUMO

INTRODUCTION: Gallbladder with a short cystic duct draining to the accessory right anterior hepatic duct is a rare variation. It is frequently associated with bile duct injury during laparoscopic cholecystectomy. We present a case of a gallbladder with this variation safely treated with laparoscopic cholecystectomy using indocyanine green (ICG) fluorescence imaging. PRESENTATION OF CASE: A 57-year-old man had right upper quadrant pain and showed a gallbladder stone on a preoperative computed tomography. Bile duct anomaly was not detected before operation. However, a short cystic duct draining to the accessory right anterior hepatic duct intraoperatively was found using ICG fluorescence imaging. To confirm the exact anatomy, we firstly detached the gallbladder from the liver with a "fundus first technique" and visualized the whole course of the short cystic duct and the accessory right anterior with ICG fluorescence imaging. Laparoscopic cholecystectomy was completed safely. No bile leakage was detected on ICG fluorescence imaging. The patient had no postoperative complication. DISCUSSION: Accessory right hepatic duct is one of the rare variations of bile duct. It can be related to bile duct injury during laparoscopic cholecystectomy. Although it can be injured easily because of its smaller size, we can identify the short cystic duct from it with the aid of ICG fluorescence imaging without injuring the accessory right anterior hepatic duct. CONCLUSION: Laparoscopic cholecystectomy for gallbladder with a short cystic duct draining to the accessory right anterior hepatic duct can be safely performed by identifying biliary anatomy with ICG fluorescence imaging.

7.
Clin Neurol Neurosurg ; 244: 108414, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-39002271

RESUMO

OBJECTIVE: Indocyanine green (ICG) and sodium fluorescein (Na-Fl) are two fluorophores, which are used for videoangiography purposes. This prospective study reports our experience by using surgical microscopes equipped with two special filters. We compared the imaging efficacy of Na-FL and ICG videoangiography techniques during aneurysm and arteriovenous malformations (AVM) surgeries. PATIENT AND METHODS: Fourtynine consecutive patients were operated between September 2015 and December 2022. Patients with ruptured/unruptured aneurysms or with AVMs presented with/without hemorrhage were included to the current study. RESULTS: There were a total of 48 aneurysms and 11 AVMs in 49 patients in the current study. Na-Fl enables the surgeon to manipulate vessels and aneurysms real-time. ICG provides the ability to watch the videoangiography repeatedly and understand the angioarchitecture. The use of FLOW-800 module allows the surgeon to make concrete judgements about the flow dynamics of AVMs and therefore ICG videoangiography found useful in AVM surgery. Na-Fl has been found more useful for the evalution of the low caliber perforating arteries and anatomical features of the aneursym dome in aneurysm surgery. CONCLUSION: The results of our series demonstrated the safety and efficacy of Na-Fl use in the surgery of aneurysms and AVMs. Both the ICG and Na-Fl videoangiographies are easy to perform and complimentary to each other. Combined use of these two mediums may provide better surgical results, considering the separate advantages and disadvantages of these both techniques.

8.
Diabetes Res Clin Pract ; 214: 111772, 2024 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-38972600

RESUMO

INTRODUCTION: Diabetes Mellitus (DM) is a common chronic disease, affecting 435 million people globally. Impaired vasculature in DM patients leads to complications like lower extremity arterial disease (LEAD) and foot ulcers, often resulting in amputations. DM causes additional peripheral neuropathy leading to multifactorial wound problems. Current diagnostics often deem unreliable, but Near-Infrared Fluorescence with Indocyanine Green (ICG NIR) can be used to assess the foot perfusion. Therefore, this study explores DM's impact on foot perfusion using ICG NIR. METHODS: Baseline ICG NIR fluorescence imaging was performed in LEAD patients with and without DM. Ten perfusion parameters were extracted and analyzed to assess differences in perfusion patterns. RESULTS: Among 109 patients (122 limbs) of the included patients, 32.8 % had DM. Six of ten perfusion parameters, mainly inflow-related, differed significantly between DM and non-DM patients (p-values 0.007-0.039). Fontaine stage 4 DM patients had the highest in- and outflow values, with seven parameters significantly higher (p-values 0.004-0.035). CONCLUSION: DM is associated with increased in- and outflow parameters. Patients with- and without DM should not be compared directly due to different vascular pathophysiology and multifactorial wound problems in DM patients. Quantified ICG NIR fluorescence imaging offers additional insight into the effect of DM on foot perfusion.

9.
Cureus ; 16(5): e61336, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38947581

RESUMO

BACKGROUND: Cervical cancer is the fourth most common cause of malignant tumor-related deaths among women in developing nations. Cervical cancer has been estimated to cause 527.600 new cases and 265.700 deaths globally per year. OBJECTIVES: This study aimed to evaluate patients with cervical cancer by ultrastaging all the lymph nodes (LN), sentinel LN (SLN) and non-SLN, to increase the sensitivity of the detection of LN metastases and the diagnostic accuracy in cervical cancer with a five-year follow-up. MATERIALS AND METHODS: This is a retrospective study of 14 cervical cancer cases from 2017 to 2019 at the Municipal Emergency Clinical Hospital of Timisoara, Romania. The cases were selected based on their high risk of LN involvement but negative intraoperative pathologic LN. After re-evaluating all paraffin block biopsy samples from 29 cases, 14 cases were included in the study, which met all criteria for ultrastaging on surgical biopsy samples. RESULTS: Patients' ages included in the study ranged from 43 to 70 years (median: 57.14 years). According to the International Federation of Gynecology and Obstetrics (FIGO) staging, the majority of the patients were in stage IB: seven cases (50%). The study revealed a positive correlation between patient age and FIGO staging, with Pearson's correlation coefficient of 0.707 and a p-value of less than 0.05, indicating that older patients were more likely to be diagnosed with a higher FIGO stage. The mean follow-up was 34.5 months, and the median follow-up was 36 months (range: 6-60 months). We obtained 167 nodes, with a mean of 11.92 nodes/case. Twenty-one LN were found to be positive with the ultrastaging method. We detected 11 LN with macrometastases (MAC) (52.38%), seven with micrometastasis (MIC) (33.3%), and three with tumor cell islets (14.4%). That would be 13% of newly diagnosed ultrastaging cases as positive nodes. This ultrastaging method detected nodal MIC in eight (57.1%) out of the 14 patients, who initially tested negative for LN involvement using the routine Hematoxylin and Eosin (HE) method. The detection of micrometastases in these patients underscored the superior sensitivity of ultrastaging, which was further highlighted by the subsequent relapse of four (28.57%) out of these eight patients. The study also found no correlation between the FIGO standardization and the number of MIC found in these patients. CONCLUSIONS: Predicting cervical LN metastasis (LNM) is crucial for improving survival rates and reducing recurrence. Very few small cohort studies used an ultrastaging method to assess non-SLNs; most of them only assessed SLNs. We showed in our study that the ultrastaging method, both in the case of SLN and non-SLN, is superior compared with H&E analysis, with a 13% rate of new positive nodule diagnosis. Metastatic involvement of non-SLN was found in over 50% of all cases (8/14) according to the ultrastaging method. Additionally, our study confirms that the sensitivity of SLN ultrastaging is high for the presence of both MIC and MAC in SLN pelvic LN. As a result, we feel that ultrastaging is the most effective method for SLN analysis in patients with early-stage cervical cancer, and bilateral detection is preferable, significantly reducing false-negative results. The routine use of SLN along with ultrastaging would lead to more accurate surgical staging and better oncological follow-up of cases.

10.
Heliyon ; 10(12): e31989, 2024 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-38952371

RESUMO

Hundreds of scientific documents have reported on the application of indocyanine green (ICG) in hepatobiliary surgery in the past 13 years, but few bibliometric studies have been conducted. This study aimed to identify the situations of authors, countries/regions, institutions, journals, and hot topics in this field. The overall status and prospects of the current research in this field can be elucidated by bibliometric analysis. Publications from 2008 to 2021 were retrieved from the Web of Science (WoS) Core Collection. The search terms included "liver," "hepatic," "gallbladder," "bile duct," "surgery," "hepatectomy," "ICG," "indocyanine green," and related synonyms. The full records of the search results were exported in text, and the cooperation network and hot topics were evaluated and visualized using CiteSpace software. The number of publications increased between 2008 and 2021. A total of 1527 publications were included in the results, and the frequency of citations was 30,742. The largest proportion of the publications emanated from Japan, and the majority of the papers were published by Kokudo. Tian Jie contributed the largest number of papers in China. Research was relatively concentrated among one country/region. The latest hotspots, "preservation" and "resistance", frequently occurred. Cooperation between authors, countries, and institutions needs to be strengthened for high-quality research. Recent studies have focused on hepatectomy, bile duct resection, liver transplantation, and tumors in this field. Future research may focus on other aspects, such as liver preservation and resistance.

11.
World J Gastrointest Surg ; 16(6): 1825-1834, 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38983318

RESUMO

BACKGROUND: Application of indocyanine green (ICG) fluorescence has led to new developments in gastrointestinal surgery. However, little is known about the use of ICG for the diagnosis of postoperative gut leakage (GL). In addition, there is a lack of rapid and intuitive methods to definitively diagnose postoperative GL. AIM: To investigate the effect of ICG in the diagnosis of anastomotic leakage in a surgical rat GL model and evaluate its diagnostic value in colorectal surgery patients. METHODS: Sixteen rats were divided into two groups: GL group (n = 8) and sham group (n = 8). Approximately 0.5 mL of ICG (2.5 mg/mL) was intravenously injected postoperatively. The peritoneal fluid was collected for the fluorescence test at 24 and 48 h. Six patients with rectal cancer who had undergone laparoscopic rectal cancer resection plus enterostomies were injected with 10 mL of ICG (2.5 mg/mL) on postoperative day 1. Their ostomy fluids were collected 24 h after ICG injection to identify the possibility of the ICG excreting from the peripheral veins to the enterostomy stoma. Participants who had undergone colectomy or rectal cancer resection were enrolled in the diagnostic test. The peritoneal fluids from drainage were collected 24 h after ICG injection. The ICG fluorescence test was conducted using OptoMedic endoscopy along with a near-infrared fluorescent imaging system. RESULTS: The peritoneal fluids from the GL group showed ICG-dependent green fluorescence in contrast to the sham group. Six samples of ostomy fluids showed green fluorescence, indicating the possibility of ICG excreting from the peripheral veins to the enterostomy stoma in patients. The peritoneal fluid ICG test exhibited a sensitivity of 100% and a specificity of 83.3% for the diagnosis of GL. The positive predictive value was 71.4%, while the negative predictive value was 100%. The likelihood ratios were 6.0 for a positive test result and 0 for a negative result. CONCLUSION: The postoperative ICG test in a drainage tube is a valuable and simple technique for the diagnosis of GL. Hence, it should be employed in clinical settings in patients with suspected GL.

12.
World J Gastrointest Surg ; 16(6): 1883-1893, 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38983339

RESUMO

BACKGROUND: Gastric cancer is a common malignant tumor of the digestive system worldwide, and its early diagnosis is crucial to improve the survival rate of patients. Indocyanine green fluorescence imaging (ICG-FI), as a new imaging technology, has shown potential application prospects in oncology surgery. The meta-analysis to study the application value of ICG-FI in the diagnosis of gastric cancer sentinel lymph node biopsy is helpful to comprehensively evaluate the clinical effect of this technology and provide more reliable guidance for clinical practice. AIM: To assess the diagnostic efficacy of optical imaging in conjunction with indocyanine green (ICG)-guided sentinel lymph node (SLN) biopsy for gastric cancer. METHODS: Electronic databases such as PubMed, Embase, Medline, Web of Science, and the Cochrane Library were searched for prospective diagnostic tests of optical imaging combined with ICG-guided SLN biopsy. Stata 12.0 software was used for analysis by combining the "bivariable mixed effect model" with the "midas" command. The true positive value, false positive value, false negative value, true negative value, and other information from the included literature were extracted. A literature quality assessment map was drawn to describe the overall quality of the included literature. A forest plot was used for heterogeneity analysis, and P < 0.01 was considered to indicate statistical significance. A funnel plot was used to assess publication bias, and P < 0.1 was considered to indicate statistical significance. The summary receiver operating characteristic (SROC) curve was used to calculate the area under the curve (AUC) to determine the diagnostic accuracy. If there was interstudy heterogeneity (I 2 > 50%), meta-regression analysis and subgroup analysis were performed. RESULTS: Optical imaging involves two methods: Near-infrared (NIR) imaging and fluorescence imaging. A combination of optical imaging and ICG-guided SLN biopsy was useful for diagnosis. The positive likelihood ratio was 30.39 (95%CI: 0.92-1.00), the sensitivity was 0.95 (95%CI: 0.82-0.99), and the specificity was 1.00 (95%CI: 0.92-1.00). The negative likelihood ratio was 0.05 (95%CI: 0.01-0.20), the diagnostic odds ratio was 225.54 (95%CI: 88.81-572.77), and the SROC AUC was 1.00 (95%CI: The crucial values were sensitivity = 0.95 (95%CI: 0.82-0.99) and specificity = 1.00 (95%CI: 0.92-1.00). The Deeks method revealed that the "diagnostic odds ratio" funnel plot of SLN biopsy for gastric cancer was significantly asymmetrical (P = 0.01), suggesting significant publication bias. Further meta-subgroup analysis revealed that, compared with fluorescence imaging, NIR imaging had greater sensitivity (0.98 vs 0.73). Compared with optical imaging immediately after ICG injection, optical imaging after 20 minutes obtained greater sensitivity (0.98 vs 0.70). Compared with that of patients with an average SLN detection number < 4, the sensitivity of patients with a SLN detection number ≥ 4 was greater (0.96 vs 0.68). Compared with hematoxylin-eosin (HE) staining, immunohistochemical (+ HE) staining showed greater sensitivity (0.99 vs 0.84). Compared with subserous injection of ICG, submucosal injection achieved greater sensitivity (0.98 vs 0.40). Compared with 5 g/L ICG, 0.5 and 0.05 g/L ICG had greater sensitivity (0.98 vs 0.83), and cT1 stage had greater sensitivity (0.96 vs 0.72) than cT2 to cT3 clinical stage. Compared with that of patients ≤ 26, the sensitivity of patients > 26 was greater (0.96 vs 0.65). Compared with the literature published before 2010, the sensitivity of the literature published after 2010 was greater (0.97 vs 0.81), and the differences were statistically significant (all P < 0.05). CONCLUSION: For the diagnosis of stomach cancer, optical imaging in conjunction with ICG-guided SLN biopsy is a therapeutically viable approach, especially for early gastric cancer. The concentration of ICG used in the SLN biopsy of gastric cancer may be too high. Moreover, NIR imaging is better than fluorescence imaging and may obtain higher sensitivity.

13.
Khirurgiia (Mosk) ; (7): 115-123, 2024.
Artigo em Russo | MEDLINE | ID: mdl-39008705

RESUMO

OBJECTIVE: To examine the specific characteristics of ICG-angiography during various bariatric interventions. MATERIAL AND METHODS: The study included 329 patients, with 105 (32%) undergoing sleeve gastrectomy (LSG), 98 (30%) undergoing mini-gastricbypass (MGB), 126 (38%) undergoing Roux-en-Y gastric bypass (RGB). Intraoperative ICG angiography was perfomed on all patients at 'control points', the perfusion of the gastric stump was qualitatively and quantitatively assessed. RESULTS: Intraoperative ICG angiography shows that during LSG the angioarchitectonics in the area of the His angle are crucial. The presence of the posterior gastric artery of the gastric main type is a prognostically unfavorable risk factor for the development of ischemic complications. Therefore, to expand the gastric stump it is necessary to suture a 40Fr nasogastric tube and perform peritonization of the staple line. Statistical difference in blood supply at three points were found between and within the two groups of patients (Gis angle area, gastric body, pyloric region) with a p-value <0.001. During MGB, one of the important stages is applying the first (transverse) stapler cassette between the branches of the right and left gastric arteries. This maintains blood supply in anastomosis area, preventing immediate complications such as GEA failure, as well as long-term complications like atrophic gastritis, peptic ulcers, and GEA stenosis. CONCLUSION: ICG angiography is a useful method for intraoperative assessment of angioarchitecture and perfusion of the gastric stump during bariatric surgery. This helps prevent tissue ischemia and reduce the risk of early and late postoperative complications.


Assuntos
Angiografia , Cirurgia Bariátrica , Verde de Indocianina , Humanos , Masculino , Feminino , Adulto , Cirurgia Bariátrica/métodos , Cirurgia Bariátrica/efeitos adversos , Pessoa de Meia-Idade , Angiografia/métodos , Verde de Indocianina/administração & dosagem , Verde de Indocianina/farmacologia , Gastrectomia/métodos , Gastrectomia/efeitos adversos , Obesidade Mórbida/cirurgia , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/etiologia , Estômago/irrigação sanguínea , Estômago/cirurgia , Estômago/diagnóstico por imagem , Artéria Gástrica/cirurgia , Monitorização Intraoperatória/métodos
14.
Khirurgiia (Mosk) ; (7): 111-114, 2024.
Artigo em Russo | MEDLINE | ID: mdl-39008704

RESUMO

OBJECTIVE: To evaluate the possibility of using the method of sentinel lymph nodes (SLN) detection with indocyanine green (ICG) in patients with early breast cancer and its informativeness. MATERIAL AND METHODS: A «Determination of sentinel lymph nodes by fluorescence method intraoperatively with the use of indocyanine green¼ study, in which 168 patients are currently included, is being conducted in the clinic of the N.N. Petrov NMRC of Oncology from 2017 through the present. All patients who underwent biopsy of sentinel lymph nodes (BSLN) were primary with a T1-2N0M0 stage of process. RESULTS: The average number of axillary lymph nodes removed in BSLN was 3 (1-5). Accumulation of ICG was found in 147 (88%) patients, accumulation of labeled radiocolloid - in 137 (82%), in combination of ICG/radiocolloid - in 167 (99%) based on the results of imaging. CONCLUSION: The obtained results prove that the informativeness and relative simplicity of this method use allow its application in any hospital where breast cancer is surgically treated, as well as in the absence of radioisotopic equipment.


Assuntos
Neoplasias da Mama , Verde de Indocianina , Biópsia de Linfonodo Sentinela , Humanos , Neoplasias da Mama/cirurgia , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/patologia , Feminino , Verde de Indocianina/administração & dosagem , Pessoa de Meia-Idade , Biópsia de Linfonodo Sentinela/métodos , Linfonodo Sentinela/patologia , Linfonodo Sentinela/cirurgia , Estadiamento de Neoplasias , Metástase Linfática , Idoso , Axila , Adulto , Excisão de Linfonodo/métodos
15.
Artigo em Inglês | MEDLINE | ID: mdl-38995862

RESUMO

BACKGROUND: Indocyanine green (ICG) is a visible near-infrared fluorescent dye. Several studies have reported its benefit in identifying important anatomical structures, tissue vascularization, and sentinel lymph nodes in the case of tumors. Studies have shown that ICG is critical and safe in gynecologic surgeries. However, research on how ICG dye can help surgeons in laparoscopic surgeries correctly identify the course of the ureter has yet to be further investigated. METHOD: This cross-sectional study enrolled 62 gynecology attending and resident surgeons who were asked to identify the course of the ureter on images of laparoscopic surgeries. The results were then compared with images in which ICG dye highlighted the course of the ureter. The purpose of this study was to detect the ability of surgical assistants and residents to adequately identify the course of the ureter in laparoscopic pelvic surgeries. RESULTS: No statistically significant differences were found in terms of year of residency, years of experience, number of laparoscopic procedures attended, and correct identification of ureter course. ICG proved useful in identifying the correct ureteral trajectory. CONCLUSIONS: ICG can be a valuable tool to improve the correct identification of ureters and improve surgical outcomes.

16.
Ann Surg Oncol ; 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-38995449

RESUMO

BACKGROUND: Because of the complex anatomy of the right posterior hepatic pedicle, there have been few reports on standardized laparoscopic portal territory staining-guided anatomical resection of liver segment 6 (LPTAR-S6). This study aimed to elucidate the indocyanine green (ICG) fluorescence staining methods for LPTAR-S6. PATIENTS AND METHODS: LPTAR-S6 can be performed using positive and negative fluorescence staining approaches. We implemented these two approaches for patients with hepatocellular carcinoma. Descriptions of the surgical strategy and technical details are presented. RESULTS: Two patients safely underwent LPTAR-S6 using a preoperative three-dimensional reconstruction plan. The intraoperative ICG fluorescence staining effect was satisfactory, and the anatomical landmarks were fully exposed. CONCLUSIONS: A detailed preoperative three-dimensional reconstruction plan, complete intraoperative application of real-time laparoscopic ultrasound guidance, and ICG fluorescence staining can result in accurate transection of the liver parenchyma during LPTAR-S6.

17.
Artigo em Inglês | MEDLINE | ID: mdl-38967048

RESUMO

Introduction: Correctly identifying positive lymph nodes associated with pediatric renal tumors is key to guiding management. Recommended targets for lymph node sampling are commonly missed during tumor nephrectomy, particularly if minimally invasive surgery (MIS) is performed. Indocyanine green (ICG) is used for lymph node mapping in adult oncology with excellent efficacy and safety profile. Materials and Methods: A prospective study was undertaken at a single-quaternary-level pediatric surgery center. All patients undergoing MIS radical or partial nephrectomy for renal tumors 2016-2023 were included. Patients managed from 2020 onwards received intra-parenchymal ICG prior to lymph node sampling. Main Results: Twenty-five patients underwent MIS nephrectomy at mean age 2 years 10 months. Eighteen patients were pre-ICG and 7 received ICG. ICG administration successfully demonstrated fluorescent nodes in all patients. Median number of nodes sampled was three pre-ICG and seven with ICG (P = 0.009). Forty-six nodes were sampled across 7 ICG patients-33 fluorescent, 10 non-fluorescent, and 3 identified histologically. Three nodes overall contained active disease, two pre-ICG and one fluorescent node with ICG. Neither operative time (180 pre-ICG versus 161 minutes ICG, P = 0.7) nor length of stay (72 versus 84 hours, P = 0.3) were significantly affected by ICG administration. There were no adverse events associated with ICG use. Conclusions: ICG is safe and effective at identifying nodes in MIS resection of pediatric renal tumors with the potential to increase the number of nodes sampled. Further research is needed, specifically a randomized control trial with extended follow-up.

18.
J Gynecol Obstet Hum Reprod ; 53(9): 102819, 2024 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-38950735

RESUMO

The main objective of this study was to review and perform a meta-analysis of current literature on the use of indocyanine green for sentinel lymph node detection in pelvic gynecologic cancer. We included all studies focusing on indications and procedures associated with the use of ICG in gynecologic surgery and available on the Medline and Pubmed database. For the meta-analysis, random effect models were used for estimation of the 95 % detection rate and 95 % confidence interval, and stratified analyses by cancer type, concentration and localization of injection were performed. A total of 147 articles were included, of which 91 were studied in a meta-analysis. Results concerning detection rate by indocyanine green injection site were found to be 95.1 % and 97.3 % respectively for intracervical injection in 2 or 4 quadrants, and 77.0 % and 94.8 % for hysteroscopic and intradermal injection respectively. Results concerning detection rate by cancer type were 95.8 %, 95.2 %, 94.7 % and 95.7 % respectively for cervical, endometrial, vulvar and endometrial/cervical cancers. Finally, the results concerning detection rate by indocyanine green concentration were 91.2 %, 95.7 %, 96.7 % and 97.7 % for concentrations of <1.25 mg/ml, 1.25 mg/ml, 2.5 mg/ml and 5 mg/ml respectively. In conclusion, indocyanine green is shown to allow highlighting of sentinel lymph nodes with good reliability with an overall indocyanine green detection rate of 95.5 %. Our literature review revealed that indocyanine green feasibility has also been demonstrated in several surgical contexts, notably for reconstructive surgery and detection of endometriosis.

19.
J Wound Care ; 33(Sup7): S30-S41, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38973640

RESUMO

OBJECTIVE: The objective of this study was to evaluate whether a systematic image assessment protocol using SPY Elite images (LifeCell Corp., US) of viable tissue at the periphery of the surgical field was associated with positive wound healing outcomes following mastectomy and breast reconstruction. METHOD: Patients undergoing mastectomy and subsequent breast reconstruction surgery at a single tertiary medical centre were included. SPY images were prospectively analysed using a systematic image assessment protocol, and an absolute value of mean fluorescence was calculated by measuring peripheral, in-situ tissue from each image. Patient medical records were retrospectively reviewed for demographics, surgical characteristics and postoperative outcomes. These variables were statistically tested for associations with mean fluorescence. RESULTS: A total of 63 patients were included in the final analysis. We found that objectively determined mean fluorescence values were not statistically significantly associated with postoperative complications. CONCLUSION: In this study, objectively measured mean fluorescence values representing breast tissue remaining after dissection showed little utility in the assessment of postoperative wound healing outcomes as they did not identify patients who would later have complications of wound healing. DECLARATION OF INTEREST: The authors have no conflicts of interest to declare.


Assuntos
Mamoplastia , Mastectomia , Cicatrização , Humanos , Feminino , Pessoa de Meia-Idade , Adulto , Estudos Retrospectivos , Angiografia , Neoplasias da Mama/cirurgia , Idoso , Estudos Prospectivos
20.
Int J Pharm ; 661: 124456, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38986962

RESUMO

Indocyanine green is an FDA-approved fluorescent imaging dye used for determining cardiac output, hepatic function, liver blood flow, and retinal perfusion. It has been investigated preclinically in photoacoustic imaging and photothermal therapy (PTT); however, ICG photodegradation limits its biomedical applications. An aggregated form of ICG, known as J-aggregate (IJA), exhibits superior photoacoustic signals and thermal stability than the monomeric ICG. Nevertheless, IJA still suffers from low stability in the biological milieu, and short in vivo blood circulation. To address these limitations, a range of nanocarriers have been developed to enhance IJA stability and performance. This review focuses on IJA potentials and limitations, besides the recent development of IJA-loaded nanocarriers, particularly for cancer imaging and therapy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...