1.
Sensors (Basel) ; 24(18)2024 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-39338755

RESUMO

Differential coils are frequently implemented in inductive sensing systems. They can be considered as a single coil that is made up of two or more subcoils, wound in series opposition. They can be used on the transmit or receive side of measurement systems, and, if designed correctly, ensure no coupling between coils under background conditions. By cancelling background coupling, the receive electronics only needs to be able to measure the change in coupling produced by a target. This allows for a more efficient use of the dynamic range, and for larger receive-side amplifier gain, thereby improving SNR. When subcoils are not electrically similar, it can be hard to engineer the coil to be perfectly balanced across a wide bandwidth. This paper presents an analytical model of a resonant differential coil pair that is tested and applied on a planar metal detector for the detection of buried objects. The model demonstrates the capability to balance an arbitrary differential coil pair, which has a broad applicability across a range of inductive sensor applications such as metal detection and non-destructive testing. The method is applied to the practical system. The results show that the correction resulting from this method ensures a stable balance across a significantly enhanced bandwidth. In the case studied here, the bandwidth of the experimental system is increased from 20 kHz to 90 kHz.

2.
Sensors (Basel) ; 24(16)2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-39205058

RESUMO

Electromagnetic tracking (EMT) can benefit image-guided interventions in cases where line of sight is unavailable. However, EMT can suffer from electromagnetic distortion in the presence of metal instruments. Metal instruments are widely used in laparoscopic surgery, ENT surgery, arthroscopy and many other clinical applications. In this work, we investigate the feasibility of tracking such metal instruments by placing the inductive sensor within the instrument shaft. We propose a magnetostatic model of the field within the instrument, and verify the results experimentally for frequencies from 6 kHz to 60 kHz. The impact of the instrument's dimensions, conductivity and transmitting field frequency is quantified for ranges representative of typical metal instruments used in image-guided interventions. We then performed tracking using the open-source Anser EMT system and quantify the error caused by the presence of the rod as a function of the frequency of the eight emitting coils for the system. The work clearly demonstrates why smaller tool diameters (less than 8 mm) are less susceptible to distortion, as well as identifying optimal frequencies (1 kHz to 2 kHz) for transmitter design to minimise for distortion in larger instruments.


Assuntos
Metais , Metais/química , Humanos , Cirurgia Assistida por Computador/métodos , Cirurgia Assistida por Computador/instrumentação , Magnetismo/instrumentação , Desenho de Equipamento , Campos Eletromagnéticos
3.
Micromachines (Basel) ; 15(7)2024 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-39064401

RESUMO

Inductive contact force sensors, known for their high precision and anti-interference capabilities, hold significant potential applications in fields such as wearable and medical monitoring devices. Most of the current research on inductive contact force sensors employed novel nanomaterials as sensitive elements to enhance their sensitivity and other performance characteristics. However, sensors developed through such methods typically involve complex preparation processes, high costs, and difficulty in biodegradation, which limit their further development. This article introduces a new flexible inductive contact force sensor using paper as a sensitive element. Paper inherently possesses micro- and nanostructures on its surface and interior, enabling it to sensitively convert changes in contact force into changes in displacement, making it suitable for use as the sensor's sensitive element. Additionally, the advantages of paper also include its great flexibility, low cost, wide availability, and biodegradability. Performance testing on this flexible sensor showed good repeatability, hysteresis, sensitivity, and consistency. When used in experiments for monitoring human motion and respiration, this sensor also exhibited great detection performance. The proposed inductive paper-based flexible contact force sensor, with its simple structure, easy manufacturing process, cost-effectiveness, eco-friendliness, and good sensing performance, provides new insights into research for contact force sensors.

4.
IEEE Trans Ind Electron ; 71(4): 4283-4290, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38881731

RESUMO

This paper describes a position sensor with six degrees of freedom (DoF) measurement capability. This sensor is designed for the position sensing of the rotor in a bearingless slice motor to enable active control. The sensor is designed to fit entirely under the rotor and operates by accessing the rotor bottom surface only, enabling packaging of the pump on the top of the rotor. The sensor has two parts; both operate using eddy currents. One of these parts measures the two radial DoF of the rotor. The other part measures the axial, angular rotation and tip/tilt DoF. The sensor utilizes a conductive target fixed to the underside of the rotor. Motion of this target varies the magnetic fields which can then be measured by the sensor as variation in either induced voltage or inductance value. The design and fabrication of the sensor along with the signal processing methods are presented in detail. The radial position measurements are the most critical for active levitation due to the small working gaps in these DoF, hence a resolution of < 1.2 ​ µ m and bandwidth of 1 kHz is achieved. This paper also describes the closed-loop behavior of a bearingless motor using this sensor.

5.
Sensors (Basel) ; 23(5)2023 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-36904576

RESUMO

We demonstrate how resonant planar coils may be used as sensors to detect and quantify magnetic nanoparticles reliably. A coil's resonant frequency depends on the adjacent materials' magnetic permeability and electric permittivity. A small number of nanoparticles dispersed on a supporting matrix on top of a planar coil circuit may thus be quantified. Such nanoparticle detection has application detection to create new devices to assess biomedicine, food quality assurance, and environmental control challenges. We developed a mathematical model for the inductive sensor response at radio frequencies to obtain the nanoparticles' mass from the self-resonance frequency of the coil. In the model, the calibration parameters only depend on the refraction index of the material around the coil, not on the separate magnetic permeability and electric permittivity. The model compares favourably with three-dimensional electromagnetic simulations and independent experimental measurements. The sensor can be scaled and automated in portable devices to measure small quantities of nanoparticles at a low cost. The resonant sensor combined with the mathematical model is a significant improvement over simple inductive sensors, which operate at smaller frequencies and do not have the required sensitivity, and oscillator-based inductive sensors, which focus on just magnetic permeability.

6.
Sensors (Basel) ; 22(14)2022 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-35890894

RESUMO

Sensors based on chaotic oscillators have a simple design, combined with high sensitivity and energy efficiency. Among many developed schemes of such sensors, the promising one is based on the Duffing oscillator, which possesses a remarkable property of demonstrating chaotic oscillations only in the presence of a weak sine wave at the input. The main goal of this research was to evaluate the maximal sensitivity of a practically implemented metal detector based on the Duffing oscillator and compare its sensitivity with conventional sensors. To achieve high efficiency of the Duffing-based design, we proposed an algorithm which performs a bifurcation analysis of any chaotic system, classifies the oscillation modes and determines the system sensitivity to a change in different parameters. We apply the developed algorithm to improve the sensitivity of the electronic circuit implementing the Duffing oscillator, serving as a key part of a three-coil metal detector. We show that the developed design allows detecting the presence of metal objects near the coils more reliably than the conventional signal analysis techniques, and the developed detector is capable of sensing a large metal plate at distances up to 2.8 of the coil diameter, which can be considered a state-of-the-art result.

7.
Sensors (Basel) ; 22(15)2022 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-35898013

RESUMO

This paper presents a new water-level-sensing mechanism based on planar coils fabricated on a printed circuit board (PCB). In addition to level, the sensor detects any relative increase in conductivity compared to that of clean water, which is an indicator of its quality. The sensing mechanism utilizes the eddy current induced in the water column, the corresponding change in the coil inductance, and the change in the turn-to-turn capacitance of the coil in the presence of water. Although several level sensors are available, there is none that gives the level and quality information using a single sensing element. Since both water quantity and quality measurements are fundamental in realizing efficient water and wastewater management, obtaining these two parameters from the same sensor is very beneficial. A scalable, planar coil-based sensor that helps achieve this goal is designed, fabricated, and tested in a laboratory setting. The results illustrate that the reactance of the sensor coil measured at a frequency (1 kHz for the prototype) much lower than the self-resonance of the coil gives reliable information about the level of water, while the measurement made at resonance, using an inductance-to-digital converter, is a clear indicator of its conductivity and, hence, quality.

8.
Nanomaterials (Basel) ; 12(12)2022 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-35745381

RESUMO

Lateral flow immunoassays for detecting biomarkers in body fluids are simple, quick, inexpensive point-of-care tests widely used in disease surveillance, such as during the coronavirus disease 2019 (COVID-19) pandemic. Improvements in sensitivity would increase their utility in healthcare, food safety, and environmental control. Recently, biofunctional magnetic nanoclusters have been used to selectively label target proteins, which allows their detection and quantification with a magneto-inductive sensor. This type of detector is easily integrated with the lateral flow immunoassay format. Pneumolysin is a cholesterol-dependent cytolysin and one of the most important protein virulence factors of pneumonia produced by Streptococcus pneumoniae. It is recognized as an important biomarker for diagnosis in urine samples. Pneumonia is the infectious disease that causes the most deaths globally, especially among children under five years and adults over 65 years, most of them in low- and middle-income countries. There especially, a rapid diagnostic urine test for pneumococcal pneumonia with high sensitivity and specificity would be helpful in primary care. In this work, a lateral flow immunoassay with magnetic nanoclusters conjugated to anti-pneumolysin antibodies was combined with two strategies to increase the technique's performance. First, magnetic concentration of the protein before the immunoassay was followed by quantification by means of a mobile telephone camera, and the inductive sensor resulted in detection limits as low as 0.57 ng (telephone camera) and 0.24 ng (inductive sensor) of pneumolysin per milliliter. Second, magnetic relocation of the particles within the test strip after the immunoassay was completed increased the detected signal by 20%. Such results obtained with portable devices are promising when compared to non-portable conventional pneumolysin detection techniques such as enzyme-linked immunosorbent assays. The combination and optimization of these approaches would have excellent application in point-of-care biodetection to reduce antibiotic misuse, hospitalizations, and deaths from community-acquired pneumonia.

9.
Sensors (Basel) ; 21(16)2021 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-34450977

RESUMO

Certain applications require a contactless measurement to eliminate the risk of sensor-induced sample contamination. Examples can be found in chemical process control, biotechnology or medical technology. For instance, in critically ill patients requiring renal replacement therapy, continuous in-line monitoring of blood conductivity as a measure for sodium should be considered. A differential inductive sensing system based on a differential transformer using a specific flow chamber has already proven suitable for this application. However, since the blood in renal replacement therapy is carried in plastic tubing, a direct measurement through the tubing offers a contactless method. Therefore, in this work we present a differential transformer for measuring directly through electrically non-conductive tubing by winding the tube around the ferrite core of the transformer. Here, the dependence of the winding type and the number of turns of the tubing on the sensitivity has been analyzed by using a mathematical model, simulations and experimental validation. A maximum sensitivity of 364.9 mV/mol/L is measured for radial winding around the core. A longitudinal winding turns out to be less effective with 92.8 mV/mol/L. However, the findings prove the ability to use the differential transformer as a truly contactless sensing system.


Assuntos
Fenômenos Eletromagnéticos , Modelos Teóricos , Fenômenos Químicos , Condutividade Elétrica , Desenho de Equipamento , Humanos
10.
Sensors (Basel) ; 21(8)2021 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-33923811

RESUMO

Electromagnetic tracking is a safe, reliable, and cost-effective method to track medical instruments in image-guided surgical navigation. However, patient motion and magnetic field distortions heavily impact the accuracy of tracked position and orientation. The use of redundant magnetic sensors can help to map and mitigate for patient movements and magnetic field distortions within the tracking region. We propose a planar inductive sensor design, printed on PCB and embedded into medical patches. The main advantage is the high repeatability and the cost benefit of using mass PCB manufacturing processes. The article presents new operative formulas for electromagnetic tracking of planar coils on the centimetre scale. The full magnetic analytical model is based on the mutual inductance between coils which can be approximated as being composed by straight conductive filaments. The full model is used to perform accurate system simulations and to assess the accuracy of faster simplified magnetic models, which are necessary to achieve real-time tracking in medical applications.


Assuntos
Fenômenos Eletromagnéticos , Cirurgia Assistida por Computador , Humanos , Campos Magnéticos
11.
Sensors (Basel) ; 21(7)2021 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-33806160

RESUMO

This study proposes a soft inductive coil spring (SICS) strain sensor that can measure the strain of soft actuators. The SICS sensor, produced by transforming a shape memory alloy (SMA) wire with the same materials as that of an SMA spring bundle actuator (SSBA) into a coil spring shape, measures inductance changes according to length changes. This study also proposes a manufacturing method, output characteristics of the SICS sensor applicable to the SSBA among soft actuators, and the structure of the SICS sensor-integrated SSBA (SI-SSBA). In the SI-SSBA, the SMA spring bundle and SICS sensor have structures corresponding to the muscle fiber and spindle of the skeletal muscle, respectively. It is demonstrated that when a robotic arm with one degree of freedom is operated by attaching two SI-SSBAs in an antagonistic structure, the displacement of the SSBA can be measured using the proposed strain sensor. The output characteristics of the SICS sensor for the driving speed of the robotic arm were evaluated, and it was experimentally proven that the strain of the SSBA can be stably measured in water under a temperature change of 54 °C from 36 to 90 °C.

12.
Sensors (Basel) ; 20(19)2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33019604

RESUMO

Liner-to-socket distance measurement using inductive sensing may be an effective means to continuously monitor socket fit in people using trans-tibial prostheses. A practical limitation, however, is a means to incorporate a thin uniform-thickness layer of conductive or magnetically permeable target material into the wide range of prosthetic liner products that people with limb amputation commonly use. In this paper, a method is presented whereby a 0.50-mm thickness ferrous polymer made from a SEEPS polymer and iron powder that is formed adjacent to a 0.25-mm thick non-ferrous layer of SEEPS polymer is assembled between two sheets of elastic fabric material. Bench testing showed that the fabrication procedure achieved a root-mean-square error in the thickness of this construct of 58 µm, helping to create a consistent calibration result over the entire surface. The original fabric backing of an off-the-shelf prosthetic liner was removed and replaced with the developed construct. When worn in the shoe of an able-bodied participant for 7.5 h per day for 28 days, the sensor well maintained the shape of its calibration curve at the start of wear, but a distance offset (shifting of the y-intercept) was introduced that increased during the initial approximately 12 days of wear. When the distance offset was corrected, for the primary distance range of clinical interest for this application (0.00-5.00 mm), the sensor maintained its calibration within 4.4%. Before being used in clinical application for liner-to-socket distance monitoring, new ferrous liners may need to be pre-worn so as to achieve a consistent distance reference.


Assuntos
Membros Artificiais , Compostos Ferrosos , Polímeros , Desenho de Prótese , Amputação Cirúrgica , Cotos de Amputação , Humanos
13.
Sensors (Basel) ; 20(7)2020 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-32218196

RESUMO

The simultaneous and independent measurements of two-dimensional (2D) displacements are significant for 2D positioning. Here a planar inductive sensor which is based on the principle of electromagnetic induction is proposed. The sensor is composed of a primary coil and a secondary coil. The primary coil consists of an array of planar spiral coils which are arranged as an m × n matrix. The primary coil is supplied with 4 kHz alternating current to generate an array of pulsating magnetic field. The secondary coil contains four spiral coils which are arranged as a 2 × 2 matrix. Thereby, four roads of modulated signals whose amplitudes vary with displacements of the secondary coil along x- and y-axis are induced. An algorithm based on the Coordinate Rotation Digital Computer algorithm is introduced to resolve the planar displacements. The structure and working principle of the sensor are proposed firstly. Then, the finite element analysis of the electromagnetic model and the numerical simulation of the algorithm are given. An experiment has been performed on a sensor prototype and the results show that the proposed scheme is feasible. Measurement error analysis of the sensor has been pursued at the end of the paper.

14.
Sensors (Basel) ; 19(19)2019 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-31590395

RESUMO

Engineering solutions based on dynamical chaos may improve the characteristics of various sensors such as metal detectors, salinometers, optical and magnetic field sensors, and so on. In this study, we investigated the possibility of creating inductive sensors based on Sprott chaotic oscillators with a planar printed circuit board inductive coil. The electric circuit of each sensor was obtained by merging two parts, namely, a harmonic oscillator and a nonlinear filter. A novel method for real-time oscillation analysis using a bandpass filter is presented. The suggested design technique was experimentally validated, and the sensor prototype showed characteristics making it practically applicable. In addition, the proposed technique can be used for the development of other types of sensors based on chaotic oscillators.

15.
Sensors (Basel) ; 19(18)2019 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-31546816

RESUMO

The purpose of this research was to create a thin ferrous polymer composite to be used as a target for inductive sensing in limb prosthetics. Inductive sensors are used to monitor limb-to-socket distance in prosthetic sockets, which reflects socket fit. A styrene-ethylene-ethylene/propylene-styrene (SEEPS) polymer was mixed with iron powder at three concentrations (75, 77, 85 wt%), and thin disk-shaped samples were fabricated (0.50, 0,75, 1.00 mm thickness). For 85 wt% samples of 0.50 mm thickness, which proved the best combination of high signal strength and low target volume, inductive sensor sensitivity ranged from 3.2E5 counts/mm at 0.00-1.00 mm distances to 7.2E4 counts/mm at 4.00-5.00 mm distances. The application of compressive stress (up to 425 kPa) introduced an absolute measurement error of less than 3.3 µm. Tensile elasticity was 282 kPa, which is comparable to that of commercial elastomeric liners. Durability testing in the shoe of an able-bodied participant demonstrated a change in calibration coefficient of less than 3.8% over two weeks of wear. The ferrous polymer composite may facilitate the development of automatically adjusting sockets that use limb-to-socket distance measurement for feedback control.


Assuntos
Membros Artificiais , Polímeros/química , Dispositivos Eletrônicos Vestíveis , Fenômenos Biomecânicos , Elasticidade , Desenho de Equipamento , Humanos , Ferro/química , Magnetismo , Sapatos , Resistência à Tração
16.
Sensors (Basel) ; 19(17)2019 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-31450693

RESUMO

Turbine tip clearance of aero-engine is important to engine performance. Proper tip clearance can reduce the gas leakage over turbine blade tips and improve the engine efficiency of turbo machinery and reduce the fuel consumption. Therefore, accurate tip clearance measurement is essential. The inductive measurement method is one of the non-contact distance measurement methods, which has the characteristics of high sensitivity, fast response speed, and strong anti-interference ability. Based on the principle of inductive sensor measuring tip clearance, the ambient temperature change may cause the material electromagnetic performance change for the conductivity and permeability varies with temperature. In order to verify the temperature effect on the sensor performance, the repeated calibration experiments were carried out to obtain the sensor repeatability error of 5.4%. Then, the sensor was calibrated in the range of 0mm-4mm clearance at temperature from 600 °C to 1000 °C and obtained the measurement error of 4.6%. Results indicate when the temperature ranged from 600 °C to 1000 °C, clearance measurement error is smaller than the sensor repeatability error so the temperature effect on the sensor characteristics can be ignored. This conclusion makes the sensor promising for monitoring the blade tip clearances at various temperature environment.

17.
Sensors (Basel) ; 19(15)2019 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-31357390

RESUMO

This paper presents a system dedicated to monitoring the heart activity parameters using Electrocardiography (ECG) mobile devices and a Wearable Heart Monitoring Inductive Sensor (WHMIS) that represents a new method and device, developed by us as an experimental model, used to assess the mechanical activity of the hearth using inductive sensors that are inserted in the fabric of the clothes. Only one inductive sensor is incorporated in the clothes in front of the apex area and it is able to assess the cardiorespiratory activity while in the prior of the art are presented methods that predict sensors arrays which are distributed in more places of the body. The parameters that are assessed are heart data-rate and respiration. The results are considered preliminary in order to prove the feasibility of this method. The main goal of the study is to extract the respiration and the data-rate parameters from the same output signal generated by the inductance-to-number convertor using a proper algorithm. The conceived device is meant to be part of the "wear and forget" equipment dedicated to monitoring the vital signs continuously.


Assuntos
Técnicas Biossensoriais , Eletrocardiografia/métodos , Coração/fisiologia , Monitorização Fisiológica , Algoritmos , Frequência Cardíaca/fisiologia , Humanos , Respiração , Têxteis , Dispositivos Eletrônicos Vestíveis
18.
Micromachines (Basel) ; 10(7)2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-31266180

RESUMO

The inductive detection of wear debris in lubrication oil is an effective method to monitor the machine status. As the wear debris is usually micro scale, a micro inductive sensor is always used to detect them in research papers or high-tech products. However, the improvement of detection sensitivity for micro inductive sensors is still a great challenge, especially for early wear debris of 20 µm or smaller diameter. This paper proposes a novel method to improve the detection sensitivity of a micro inductive sensor. Regarding the magnetic powder surrounding the sensor, the magnetic field in the core of the sensor where the wear debris pass through would be enhanced due to the increased relative permeability. Thus, the inductive signal would be improved and the detection sensitivity would be increased. It is found that the inductive signal would linearly increase with increasing the concentration of the magnetic powder and this enhancement would also be effective for wear debris of different sizes. In addition, the detection limit of the micro inductive sensor used in our experiment could be extended to 11 µm wear debris by the proposed method.

19.
Micromachines (Basel) ; 10(4)2019 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-31013939

RESUMO

Inductive wear debris sensor has been widely used in real time machine lubricant oil condition monitoring and fault forecasting. However, the small sensing zone, which is designed for high sensitivity, of the existing sensors leads to low throughput. In order to improve the throughput, a novel multichannel wear debris sensor that is based on phase division multiplexing is presented. By introducing the phase shift circuit into the system, multiple sensing coils could work at different initial phases. Multiple signals of sensing coils could be combined into one output without information loss. Synchronized sampling is used for data recording, and output signals of multiple sensing coils are extracted from the recorded data. A four-channel wear debris sensor system was designed to demonstrate our method. Subsequently, crosstalk analysis, pseudo-dynamic testing and dynamic testing were conducted to check the sensing system. Results show that signals of four sensing coils could be simultaneously detected and the detection limit for ferrous wear debris is 33 µm. Using the presented method, real time wear debris detection in multiple channels could be achieved without increasing the number of excitation source and data acquisition equipment.

20.
Sensors (Basel) ; 19(1)2019 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-30609696

RESUMO

In this paper an exceptionally simple transducer is presented that is developed for experimental and custom-made sensors with inductive or resistive impedance output. It is based on a venerable 555 Integrated Circuit in a modified astable configuration. Due to single supply 5 V operation, it is directly compatible with most modern microcontroller systems, such as the popular Arduino platform. Various exemplary sensor characteristics are presented, including displacement, force, magnetic field, temperature and light sensing applications. While the transducer is not designed for high accuracy, it allows for fast and inexpensive application of various experimental sensors, such as magnetoelastic or GMI (Giant Magneto Impedance) sensors.