Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 598
Filtrar
1.
Arch Acad Emerg Med ; 13(1): e1, 2025.
Artigo em Inglês | MEDLINE | ID: mdl-39318862

RESUMO

Introduction: Intubating patients undergoing manual in-line stabilization (MILS) can make airway management more challenging. This study aimed to compare the outcomes of intubation with video-laryngoscope (VL) and Intubating Laryngeal Mask Airway (I-LMA) in manikin with restricted neck motion using MILS. Methods: In this comparative study, emergency medicine residents and paramedics were randomly allocated to two crossover sets. Then the intubation outcomes (success rate, time to successful intubation, and cervical spine movement) were compared between intubation with VL and I-LMA in a manikin model with restricted cervical spine mobility, achieved through MILS. Results: 64 participants with a mean age of 28.86 ± 4.03 (range: 24-47) years and a mean duration of intubation experience of 3.63 ± 1.35 years were studied (43.75% male, 81.3% emergency medicine resident). The intubation success rate was 62 out of 64 (96.88%) in the VL method and 52 out of 64 (81.25%) in the I-LMA method (p = 0.008). The mean time to successful intubation was 33.03±16.94 seconds in the VL method and 55.03±17.34 seconds in the I-LMA method (p < 0.001). The mean cervical range of motion (CROM) in flexion-extension was 4.38±1.82 degrees in the VL method and 4.13±3.20 degrees in the I-LMA method (p = 0.158). The mean CROM in rotation was 4.27±2.62 degrees in the VL method and 4.65±2.47 degrees in the I-LMA method (p= 0.258) and the mean CROM in lateral bending was 5.35±4.45 degrees in the VL method and 7.71±6.14 degrees in the I-LMA method (p = 0.010). Conclusion: In a manikin model with restricted cervical spine mobility, the utilization of VL significantly improved intubation success rates, reduced time to successful intubation, and limited CROM.

2.
Front Endocrinol (Lausanne) ; 15: 1403087, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39351528

RESUMO

Objective: Although radiofrequency ablation (RFA) is a safe and effective non-surgical treatment for benign thyroid nodules, injury to the recurrent laryngeal nerve (RLN), is a potential and feared complication. Intermittent voice checks have been proposed to monitor vocal cord (VC) function during RFA, but such assessment is highly subjective and effort-dependent. Methods: We are here reporting the methodological use of flexible laryngoscopy (FL) for VC monitoring during bilateral thyroid RFA treatment. The patient, a 35-year-old woman, was referred to the Endocrinology Unit for subclinical hyperthyroidism due to bilateral autonomously functioning thyroid nodules. Results: At the end of the treatment of the first nodule, the FL performed by an otorhinolaryngologist specialist allowed evaluating VC function and ruling out possible paralysis before proceeding with the contralateral RFA treatment. The patient was awake during the entire procedure and well tolerated the laryngoscopic examination. The TSH serum evaluations performed one month and 9 months after the procedure assessed an euthyroid state (TSH 3.2 mIU/L and 2.8 mIU/L, respectively). Conclusion: During bilateral thyroid RFA the use of FL for VC monitoring treatment resulted in a safe, easy-to-perform, and effective strategy to minimize and anticipate RLN injury risk in the awake patient. The prevention of RLN damage is advisable in the case of single RFA treatment, while it should be strongly recommended when RFA is performed on bilateral nodules.


Assuntos
Laringoscopia , Ablação por Radiofrequência , Traumatismos do Nervo Laríngeo Recorrente , Humanos , Feminino , Adulto , Laringoscopia/métodos , Ablação por Radiofrequência/métodos , Ablação por Radiofrequência/efeitos adversos , Traumatismos do Nervo Laríngeo Recorrente/etiologia , Traumatismos do Nervo Laríngeo Recorrente/prevenção & controle , Nódulo da Glândula Tireoide/cirurgia , Vigília , Nervo Laríngeo Recorrente/cirurgia , Glândula Tireoide/cirurgia , Monitorização Intraoperatória/métodos
3.
Resusc Plus ; 20: 100776, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-39376638

RESUMO

Introduction: Neonatal intubation is a lifesaving skill that a variety of clinicians need to establish as it can be required anywhere babies are born or hospitalised and cannot depend on the immediate availability of an experienced senior clinician. However, neonatal intubation is complex and risky, requiring technical and non-technical skill competence. Studies report that rates of successful neonatal intubation by junior clinicians are low, providing a mandate to examine the best methods to improve skill acquisition, retention, and transfer. Method: We utilised PRISMA-ScR methodology to capture the range of training approaches in the simulation and clinical settings, and to assess the range of technical and non-technical skill outcome measures that were used in the included studies. Databases were searched from inception to August 2024 to identify studies reporting outcomes for medical practitioners-in-training, nurses, and nurse practitioners. Identified studies meeting inclusion criteria underwent data charting with study characteristics tabulated. Results: Twenty-six studies (involving 1449 participants) were included. Training methodology was diverse and included self-directed learning, didactic education, demonstration, simulation-based training (SBT), instructor feedback, debriefing and supervised clinical practice. Most of the studies (96 %) used multiple training methods with education and SBT most frequently used. Thirteen studies reported outcomes in clinical settings, including seven that demonstrated changes in technical skills following education and SBT. Two studies that assessed transfer of skills failed to show successful transfer from simulation to a clinical setting. Two articles reported the transfer of skills between direct and video laryngoscope devices. Only one study evaluated skill retention (at 6-9 months) but did not demonstrate proficiency after initial training or at follow up. No studies described the effects of training on non-technical skills. Conclusion: No included studies or combination of studies seems likely to provide a high-certainty evidence-basis for optimal training methodology. Results suggested using a training bundle including education, SBT and supervision. Knowledge gaps remain, including the most effective methodology for non-technical skill training. In addition, the evidence of technical skill retention beyond the immediate training episode, and transfer to a variety of clinical environments is very limited. Given the importance of successful neonatal intubation, more research in these areas is justified.

4.
J Anaesthesiol Clin Pharmacol ; 40(3): 498-503, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39391651

RESUMO

Background and Aims: Throat pack insertion is required for many otolaryngological surgeries under general anesthesia. To facilitate surgery, an oral Ring, Adair, and Elwyn (RAE) endotracheal tube is used. When the Macintosh blade is used to insert the pack, the tube often moves to the left as per its design. We designed a groove in the Macintosh laryngoscope blade to hold the endotracheal tube in place during pack placement. This study was done to compare the grooved and conventional Macintosh laryngoscope blades for throat pack insertion with respect to the intraoral movement of the tube, ease of packing, time taken, and associated hemodynamic changes in patients who have been intubated with a preformed oral endotracheal tube. Material and Methods: This randomized control trial included 80 patients after approval from the institutional ethics committee and CTRI. Informed written consent was taken from all patients. Packing of cases was done with either grooved (group G) or conventional Macintosh laryngoscope blade (group C). Student's t-test, Chi-square test, and Mann-Whitney U test were used to analyze data. Results: The tube remained in the center in 35/40 patients in group G as compared to 10/40 patients in group C (P < 0.0001). Packing the throat was significantly easier (P = 0.005), and time taken to pack the throat was shorter in group G as compared to group C (P = 0.0008). Conclusions: The endotracheal tube remains in the center more often during throat pack insertion using a grooved laryngoscope blade as compared to the conventional Macintosh laryngoscope blade. The grooved blade is easier to use and takes less time to insert the throat pack.

5.
J Pharm Bioallied Sci ; 16(Suppl 3): S2205-S2207, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39346334

RESUMO

Background: Intubation is essential in anesthesia for patient safety, requiring accurate techniques for difficult airways. Achieving first-attempt success is crucial. This study evaluates traditional laryngoscopes, such as the Macintosh, versus advanced tools like the TAS Scope. Material and Methods: This observational study, conducted from April to August 2023 at Saveetha Medical College and Hospital, involved 60 patients aged 18-65. The two groups of Macintosh laryngoscope and TAS Scope 30 each are based on airway difficulty predictors and patient characteristics. Results: The TAS Scope group had a higher first-attempt success rate and easier intubation experiences according to Likert scale ratings. Conclusion: The study underscores the benefits of using advanced devices like the TAS Scope for difficult airway management, showing higher success rates and ease of use. These findings support the adoption of new technologies to enhance patient safety and intubation effectiveness.

6.
J Pers Med ; 14(9)2024 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-39338156

RESUMO

This study develops a predictive model for video laryngoscopic views using advanced machine learning techniques, aiming to enhance airway management's efficiency and safety. A total of 212 participants were involved, with 169 in the training set and 43 in the test set. We assessed outcomes using the percentage of glottic opening (POGO) score and considered factors like the modified Mallampati classification, thyromental height and distance, sternomental distance, mouth opening distance, and neck circumference. A range of machine learning algorithms was employed for data analysis, including Random Forest, Light Gradient Boosting Machine, K-Nearest Neighbors, Support Vector Regression, Ridge Regression, and Lasso Regression. The models' performance was evaluated on the test set, with Root Mean Squared Error values ranging from 20.4 to 21.9. SHapley Additive exPlanations value analysis revealed that age is a consistent and significant predictor of POGO score across all models, highlighting its critical role in the predictive accuracy of these techniques.

7.
Cureus ; 16(8): e66360, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39246862

RESUMO

Purpose Video laryngoscopes were being used more often in cases of potentially difficult airways. The Karl Storz video stylet offered clear advantages over conventional laryngoscopes for patients with cervical spine fractures. This study aimed to compare the performance of the C-MAC video laryngoscope with the new Karl Storz video stylet in patients with simulated cervical fracture injuries. Material and methods The study, approved by the Board of Studies and the Ethical Committee of Jawaharlal Nehru Medical College and Hospital in Aligarh, involved 50 patients undergoing operative procedures under general anaesthesia. It was a prospective randomised controlled study on patients aged 20-60, weighing 30-80 kg, and classified as American Society of Anesthesiologists (ASA) Grades I and II, admitted for elective operative procedures. Patients were randomly assigned to two groups for intubation using different devices: the control group (N = 25) was intubated with the C-MAC (Mac blade) video laryngoscope (CM), and the study group (N = 25) was intubated with the Karl Storz video stylet (VS). The anaesthetic procedure involved a detailed pre-anesthetic check-up for all patients, including a medical history review, physical examination, and necessary tests based on age. Standard monitoring and pre-medication were administered uniformly. Anesthesia was induced and intubation was attempted using appropriate devices, following manual stabilisation of the neck. Parameters such as intubation attempts, time taken, failures, hemodynamic changes, and complications were recorded throughout the procedure. If intubation was unsuccessful, alternative measures were taken, and the operative procedure proceeded. Results The intubation success rates were compared between the two groups, CM and VS. In the CM group, all 25 patients (100%) were successfully intubated on the first attempt, while in the VS group, 23 patients (92%) were successfully intubated on the first attempt, and two patients (8%) required two attempts. The difference in the distribution of the number of attempts between the two groups was not statistically significant (p = 0.4915). The mean intubation time in the CM group was 27.24 ± 2.16 seconds, while in the VS group, the mean intubation time was significantly longer at 30.84 ± 6.81 seconds, with a statistically significant difference (p = 0.0105). Adjustment manoeuvres were required in only 4% of patients in the CM group compared to 0% in the VS group, although this difference was not statistically significant. The occurrence of blood on the device during intubation was recorded, and the distribution of patients with blood on the device among the two groups did not show a statistically significant difference (p = 0.617). Conclusion This study compared the effectiveness of two intubation devices. The C-MAC video laryngoscope showed a significantly higher rate of first-attempt successful intubations and required fewer attempts compared to the Karl Storz video stylet. The C-MAC also had shorter intubation times compared to the Karl Storz device. However, the Karl Storz video stylet demonstrated comparable performance to the C-MAC video laryngoscope in clinical settings, with both devices having similar safety profiles and minimal complications.

8.
Cureus ; 16(8): e66400, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39246974

RESUMO

Background A disposable i-view® video laryngoscope (Intersurgical Limited, Berkshire, United Kingdom) is yet to be used to educate medical and dental students, who must learn endotracheal intubation skills. Additionally, the advantage of the i-view® use for the purpose, compared with the Macintosh laryngoscope, is unknown. We aimed to first determine whether the i-view® video laryngoscope enhances endotracheal intubation skills among dental students compared with the Macintosh laryngoscope. Methodology A prospective, observational, simulation study was conducted among 67 dental students in their sixth clinical year of education. Intubation skills were evaluated on a computer-assisted simulator with a standardized manikin. Each student was asked to intubate using the conventional Macintosh laryngoscope and the i-view® video laryngoscope in the trachea of the simulator's manikin. We collected objective data, including the retroflection angle of the manikin, the maxillary incisor contact pressure, time from picking up the laryngoscope to ventilation, intubation success, and intubation delay. Each student was further asked to grade their subjective evaluation concerning the visual field, Cormack and Lehane classification, operability, stability, needed force for intubation, and easiness during intubation. Results Enrolled dental students quoted that the i-view® video laryngoscope demonstrated better visual field, Cormack and Lehane classification, operability, and stability than the Macintosh laryngoscope. However, they felt intubation easiness could have been better using Macintosh than i-view®. Intubation time, failure rate, and delay rate did not differ between the two laryngoscopes. Nevertheless, the maxillary incisor contact pressure (median interquartile range (IQR)) during the intubation increased in the i-view® intubation compared with Macintosh (32 (24 to 41) vs. 25 (18 to 35) N, p = 0.010). Conclusions We first demonstrated that the i-view® video laryngoscope compared with the Macintosh laryngoscope does not enhance the endotracheal intubation skills of dental students. However, the possible repeated use as an educational simulator training tool may add some advantages to the experience of video laryngoscope in both medical and dental students.

9.
J Perioper Pract ; : 17504589241270202, 2024 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-39324661

RESUMO

BACKGROUND: Nasotracheal intubation is challenging for anaesthesiologists in faciomaxillary injuries due to the anticipated difficult airways. The effectiveness of a non-channelled McGrath video laryngoscope was compared with a conventional Macintosh laryngoscope during nasotracheal intubation. METHODS: Sixty American Society of Anaesthesiologists I-II patients aged between 18 and 60 years of both sexes undergoing elective faciomaxillary surgeries from September 2019 to February 2020 were prospectively randomised into two groups (Macintosh laryngoscope Group, McGrath video laryngoscope Group) of 30. The primary outcome was ease of intubation (Modified Intubation Difficulty Scale) and Nasotracheal intubation time (T1 time: from nostril to nasopharynx, T2 time: from nasopharynx until the first ETCO2, total time: T1 + T2). The secondary outcomes were Cormac Lehane grade, additional manoeuvres requirement, intubation failure, tracheostomy incidence and associated complications. RESULTS: T1, T2 and total (T1 + T2) time (mean ± SD) were statistically prolonged in the McGrath video laryngoscope than Macintosh laryngoscope group, with p = 0.044, p = 0.000 and p = 0.000, respectively. The McGrath video laryngoscope facilitated a better laryngoscopic view (p = 0.002), favourable intubation difficulty scale scores, less lifting force (p = 0.002), reduced lip trauma (p = 0.002) and decreased Magill's forceps use (p = 0.002) than the Macintosh laryngoscope group. CONCLUSION: Despite longer intubation time, the non-channelled McGrath video laryngoscope offered favourable intubating conditions with superior glottis view, less lifting force and reduced Magill's forceps requirement, causing decreased airway trauma, lower intubation difficulty scale scores than Macintosh laryngoscope for nasotracheal intubation.

10.
J Clin Anesth ; 98: 111590, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39178493

RESUMO

BACKGROUND: The video laryngoscope (VLS) has been proven to be an effective insertion device for airway management. However, no laryngoscope has been specifically designed for the placement of the laryngeal mask airway (LMA). We improved the current VLS and developed a novel VLS method. This study aimed to evaluate the clinical efficacy of an improved VLS for inserting a flexible laryngeal mask airway (F-LMA) compared with the standard blind method. METHODS: One hundred and fifty-seven patients who underwent F-LMA insertion under general anesthesia were randomly assigned to either the standard blind insertion technique (group B) or VLS -assisted insertion (group VL). First attempt success rates were recorded. Secondary outcomes included oropharyngeal leakage pressure (OLP), fiberoptic view, insertion time, position adjustment, reinsertion rate, and postoperative airway morbidity. RESULTS: The first-attempt success rate was higher in group VL than that in group B (99% vs. 86%; p = 0.002). The OLP was significantly higher in the VLS-guided technique (26.4 ± 5.1 vs 23.8 ± 4.4 cmH2O, p = 0.002). The fiberoptic view was significantly better in the group VL (p < 0.001) and required less readjustment and reinsertion to establish an effective airway (p < 0.001). The insertion time was shorter in the group B than that in group VL (33.9 vs 41.3 s, p < 0.001). Hemodynamic stress responses and postoperative airway complications did not differ between the two groups. CONCLUSIONS: The new VLS-guided insertion technology has a high success rate, achieves greater OLP, and provides an ideal anatomical position with minimal adjustment, without increasing the risk of hemodynamic stress or adverse events. TRIAL REGISTRATION: Chinese Clinical Trial Registry (registration number: ChiCTR2300075866; https://www.chictr.org.cn).


Assuntos
Anestesia Geral , Intubação Intratraqueal , Máscaras Laríngeas , Laringoscópios , Humanos , Máscaras Laríngeas/efeitos adversos , Masculino , Feminino , Estudos Prospectivos , Pessoa de Meia-Idade , Anestesia Geral/instrumentação , Intubação Intratraqueal/instrumentação , Intubação Intratraqueal/métodos , Intubação Intratraqueal/efeitos adversos , Adulto , Desenho de Equipamento , Idoso , Tecnologia de Fibra Óptica , Laringoscopia/métodos , Laringoscopia/instrumentação , Laringoscopia/efeitos adversos , Manuseio das Vias Aéreas/métodos , Manuseio das Vias Aéreas/instrumentação , Técnicas e Procedimentos Assistidos por Vídeo
11.
BMC Med Educ ; 24(1): 933, 2024 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-39192254

RESUMO

BACKGROUND: For both normal and difficult airway management, VL is thought to be more effective. However, VL seems far from being offered as a standard option in both healthcare delivery and educational activities in low-income countries, considering its high costs. Therefore, three-dimensional(3D)printed VLs may be considered an alternative to conventional VLs in low-income countries and other places with limited resources. Our objective was to compare the efficacy of AirAngel 3D-printed VL (3D-PVL) with those of commercially available Storz® VL (SVL) and conventional Macintosh® laryngoscope (MCL) in normal and difficult airway scenarios in the hands of inexperienced users. METHODS: This is a prospective randomized crossover manikin study that included 126 senior medical students with no experience in intubation. The effectiveness of all three laryngoscopy devices in the hands of inexperienced users was evaluated in terms of intubation time, glottic visualization, ease of use, endotracheal tube placement, and intubation success rate. Between 2020 and 2022, 126 last year medical students participated in the study. RESULTS: MCL resulted in significantly longer intubation times than 3D-PVL and SVL in the difficult airway scenario, with no significant difference between 3DPVL and SVL (Wilcoxon test, p < 0.016; Bonferroni correction MCL: 28.54 s; SVL: 26.68 s; 3DPVL: 26.64 s). Both SVL and 3D-PVL resulted in significantly better Cormack - Lehane grades in both normal and difficult airway scenarios, and thus provided better glottic viewing than MCL, with no significant difference between 3D-PVL and SVL (Wilcoxon test, p < 0.016; Bonferroni correction, MCL: 1.73; SVL: 1.29; 3DPVL: 1.25). The SVL was the easiest device to use for normal airway scenarios (1: very easy, 5: very difficult), while the MCL was the most difficult (MCL: 2.64; 3DPVL: 1.98; SVL: 1.49). Conversely, no significant difference was found between 3DPVL and other devices in terms of ease of use in difficult airway scenarios and in terms of accurate placement of the endotracheal tube and successful intubation attempts. CONCLUSION: 3D-PVL is a good educational and possible clinical alternative to conventional VL, particularly in places with limited resources, due to its low cost.


Assuntos
Estudos Cross-Over , Intubação Intratraqueal , Laringoscópios , Laringoscopia , Manequins , Humanos , Intubação Intratraqueal/instrumentação , Intubação Intratraqueal/métodos , Estudos Prospectivos , Laringoscopia/educação , Desenho de Equipamento , Competência Clínica , Masculino , Estudantes de Medicina , Impressão Tridimensional , Feminino
12.
J Voice ; 2024 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-39138041

RESUMO

OBJECTIVE: This study aims to clarify the clinical characteristics of pediatric voice disorders. METHODS: The clinical data of 1782 pediatric patients presenting with voice disorders were retrospectively analyzed. These cases were categorized into four age-based cohorts: 0-3, 4-7, 8-11, and 12-15years. Variables such as gender disparities, laryngoscopic manifestation, disease types, and acoustic parameters were thoroughly examined. RESULTS: A total of 1782 children with acoustic hoarseness were included in this study, comprising 1325 males and 457 females. When the sex ratio among the children in each group was compared, males were found to outnumber females. A notable male predominance was observed across all age groups. Laryngoscopic results revealed that the most prevalent condition was vocal cord nodules (1363 cases, 76.48%), followed by vocal cord polyps (271 cases, 15.20%). Other diseases included laryngeal papillomas, vocal fold movement impairment, vocal cord cysts, functional dysphonia, leukoplakia of the vocal cords, and benign laryngeal tumors such as laryngeal amyloidosis and subglottic granular cell tumors. Among these, adenoid hypertrophy was presented in 382 children (21.44%). Additionally, the Reflux Finding Score (RFS) was conducted, and 799 cases (44.83%) were found to have a score above 7. The distribution of various diseases across different age groups indicated that children with vocal cord nodules (637 cases, 46.74%), vocal cord polyps (109 cases, 40.22%), and laryngeal papillomas (35, 36.84%) were predominantly found in the 4-7 years age group. Pediatric acute laryngitis (three cases, 75%) and vocal fold movement impairment (eight cases, 36.36%) were more common in the 0-3 years age group. Functional dysphonia (four cases, 66.67%) and vocal cord leukoplakia (four cases, 80%) were mainly observed in the 12-15 years age group, while vocal cord cysts were predominantly seen in the 8-11 years age group (four cases, 57.14%). A comparative analysis of acoustic parameters among 153 children showed statistically significant differences in jitter, fundamental frequency (F0), voice handicap index (VHI), reflux symptom index (RSI), and RFS across different pathologies. CONCLUSION: This study highlighted that vocal cord nodules, vocal cord polyps, and laryngeal papillomas were the primary causes of pediatric hoarseness, although the possibility of tumors and rare diseases cannot be disregarded. There was a noticeable gender bias towards males, and functional dysphonia was significantly more prevalent in older children.

13.
J Nippon Med Sch ; 2024 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-39168617

RESUMO

Nasogastric tube syndrome (NGTS) is a complication of NGT placement that can cause sore throat, bilateral vocal cord paralysis, and airway constriction. Although rare, this condition should be known by all physicians because it is sometimes fatal. We report a case of NGTS that was successfully diagnosed and debrided with a rigid curved laryngoscope. A 79-year-old man was referred to our department for evaluation of persistent pharyngeal pain and dysphagia after thoracic aortic aneurysm surgery. He had restricted bilateral vocal fold abduction, and the NGT had been placed for nearly 120 days. After induction of general anesthesia, the patient underwent laryngeal examination using a rigid curved laryngoscope, which revealed ossified cricoid cartilage in the postcricoid area, leading to confirmation of NGTS. The NGT was removed, and the protruding bony lesion was debrided. Subsequently, the patient underwent gastrostomy to improve his nutritional status. One month later, the postcricoid lesion improved, and the patient was able to tolerate an oral diet. The pathophysiology of NGTS is thought to involve ulceration of the postcricoid mucosa and injury of the posterior cricoarytenoid muscle by contact with the NGT. Although the treatment has not been established, early removal of the NGT is important. In the present case, the rigid curved laryngoscope was useful for resection of the bony lesion, which contributed to early epithelialization and symptom improvement.

14.
J Clin Med ; 13(15)2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39124749

RESUMO

Background: Tracheal intubation in the Sellick and Trendelenburg position (ST position) can prevent pulmonary aspiration but increase the difficulty of tracheal intubation. We compared tracheal intubation using video and direct laryngoscopy in the ST position with direct laryngoscopy in the supine sniffing position to evaluate the overall intubation performance. Methods: One hundred and twenty patients were randomly assigned to three groups: direct laryngoscope in the supine sniffing position (control), direct laryngoscope in the ST position (ST direct), and video laryngoscope in the ST position (ST video). The primary outcome was the intubation time; secondary outcomes included the first attempt success rate of tracheal intubation, intubation difficulty scale score, operator's subjective assessment of intubation difficulty, and modified Cormack-Lehane grades. Results: The median intubation times were greater in the ST direct (36.0 s) and video (34.5 s) than the control (28.0 s) groups. The first attempt success rate decreased in the ST direct (77.5%) but not the video (95.0%) group compared with the control group (100%). Conclusions: The challenges of tracheal intubation in the ST position, aimed at reducing the risk of pulmonary aspiration, can be mitigated by using a video laryngoscope, despite slightly longer intubation times.

15.
Healthcare (Basel) ; 12(14)2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39057547

RESUMO

The aim of this case series report is to provide a new topical view of styletubation (video intubating stylet technique) in obese patients undergoing bariatric surgeries. In contrast to various conventional direct laryngoscopes (DLs), videolaryngoscopes (VLs) have been applied in such obese populations with potentially difficult airway complications. The safety and effectiveness of VLs have been repeatedly studied, and the superiority of VLs has then been observed in and advocated for routine use. In this article, among our vast use experiences with styletubation (more than 54,998 patients since 2016) for first-line routine tracheal intubation, we present the unique experience to apply the styletubation technique in obese patients undergoing bariatric surgery. Consistent with the experiences applied in other patient populations, we found the styletubation technique itself to be swift (the time to intubate from 5 s to 24 s), smooth (first-attempt success rate: 100%), safe (no airway complications), and easy (high subjective satisfaction). The learning curve is steep, but competency can be enhanced if technical pitfalls can be avoided. We, therefore, propose that the styletubation technique can be feasibly and routinely applied as a first-line airway modality in obese patients undergoing bariatric surgery.

16.
Cureus ; 16(5): e61464, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38953088

RESUMO

The use of video laryngoscopes has enhanced the visualization of the vocal cords, thereby improving the accessibility of tracheal intubation. Employing artificial intelligence (AI) to recognize images obtained through video laryngoscopy, particularly when marking the epiglottis and vocal cords, may elucidate anatomical structures and enhance anatomical comprehension of anatomy. This study investigates the ability of an AI model to accurately identify the glottis in video laryngoscope images captured from a manikin. Tracheal intubation was conducted on a manikin using a bronchoscope with recording capabilities, and image data of the glottis was gathered for creating an AI model. Data preprocessing and annotation of the vocal cords, epiglottis, and glottis were performed, and human annotation of the vocal cords, epiglottis, and glottis was carried out. Based on the AI's determinations, anatomical structures were color-coded for identification. The recognition accuracy of the epiglottis and vocal cords recognized by the AI model was 0.9516, which was over 95%. The AI successfully marked the glottis, epiglottis, and vocal cords during the tracheal intubation process. These markings significantly aided in the visual identification of the respective structures with an accuracy of more than 95%. The AI demonstrated the ability to recognize the epiglottis, vocal cords, and glottis using an image recognition model of a manikin.

17.
Anaesthesiologie ; 73(7): 473-481, 2024 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-38958671

RESUMO

Securing an airway enables the oxygenation and ventilation of the lungs and is a potentially life-saving medical procedure. Adverse and critical events are common during airway management, particularly in neonates and infants. The multifactorial reasons for this include patient-dependent, user-dependent and also external factors. The recently published joint ESAIC/BJA international guidelines on airway management in neonates and infants are summarized with a focus on the clinical application. The original publication of the guidelines focussed on naming formal recommendations based on systematically documented evidence, whereas this summary focusses particularly on the practicability of their implementation.


Assuntos
Manuseio das Vias Aéreas , Humanos , Recém-Nascido , Manuseio das Vias Aéreas/métodos , Manuseio das Vias Aéreas/normas , Lactente , Guias de Prática Clínica como Assunto , Intubação Intratraqueal/métodos , Intubação Intratraqueal/normas , Anestesiologia/métodos , Anestesiologia/normas
18.
Laryngoscope ; 134(11): 4488-4493, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38874300

RESUMO

OBJECTIVE: The purpose of this project was to develop a novel airway-exchange broncholaryngoscope (AEBLScope) to improve the efficiency and accuracy of airway-exchange procedures. METHODS: The AEBLScope was designed to combine a bronchoscope and airway-exchange catheter (AEC) into a single device and to reduce the blind placement of AECs. The prototype was constructed by modifying an existing distal-chip bronchoscope. A custom AEC was procured to fit concentrically over the flexible portion of the scope. The catheter was connected to the scope handpiece by a customized push-pull locking attachment. The AEBLScope was used to perform airway-exchange procedures with both tracheostomy and endotracheal tubes using two different airway models. Experimental procedures were recorded with still photography to evaluate the exchange of tubes and placement of AECs. RESULTS: In two airway models using the AEBLScope, both tracheostomy and endotracheal tubes were successfully exchanged on first-pass attempt, and AECs were accurately placed under visual guidance. CONCLUSION: The AEBLScope combines a bronchoscope and AEC into a single tool. Based on these first results, this novel scope has the potential to perform airway-exchange procedures more safely compared with standard procedures by increasing the accuracy of placement, decreasing procedural time, and reducing the morbidity and mortality that can occur from blind placement of AECs. LEVEL OF EVIDENCE: NA Laryngoscope, 134:4488-4493, 2024.


Assuntos
Broncoscópios , Desenho de Equipamento , Intubação Intratraqueal , Humanos , Intubação Intratraqueal/instrumentação , Intubação Intratraqueal/métodos , Traqueostomia/instrumentação , Broncoscopia/instrumentação , Broncoscopia/métodos , Laringoscópios , Laringoscopia/instrumentação , Laringoscopia/métodos
19.
Bioengineering (Basel) ; 11(6)2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38927806

RESUMO

The aim of this study was to assess the usefulness of an attachable video laryngoscope (AVL) by attaching a camera and a monitor to a conventional Macintosh laryngoscope (CML). Normal and tongue edema airway scenarios were simulated using a manikin. Twenty physicians performed tracheal intubations using CML, AVL, Pentax Airwayscope® (AWS), and McGrath MAC® (MAC) in each scenario. Ten physicians who had clinical experience in using tracheal intubation were designated as the skilled group, and another ten physicians who were affiliated with other departments and had little clinical experience using tracheal intubation were designated as the unskilled group. The time required for intubation and the success rate were recorded. The degree of difficulty of use and glottic view assessment were scored by participants. All 20 participants successfully completed the study. There was no difference in tracheal intubation success rate and intubation time in the normal airway scenario in both skilled and unskilled groups. In the experienced group, AWS had the highest success rate (100%) in the tongue edema airway scenario, followed by AVL (60%), MAC (60%), and CML (10%) (p = 0.001). The time required to intubate using AWS was significantly shorter than that with AVL (10.2 s vs. 19.2 s) or MAC (10.2 s vs. 20.4 s, p = 0.007). The difficulty of using AVL was significantly lower than that of CML (7.8 vs. 2.8; p < 0.001). For the experienced group, AVL was interpreted as being inferior to AWS but better than MAC. Similarly, in the unskilled group, AVL had a similar success rate and tracheal intubation time as MAC in the tongue edema scenario, but this was not statistically significant. The difficulty of using AVL was significantly lower than that of CML (8.8 vs. 3.3; p < 0.001). AVL may be an alternative for VL.

20.
Laryngoscope ; 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38828682

RESUMO

OBJECTIVE: To extract texture features from vocal cord leukoplakia (VCL) images and establish a VCL risk stratification prediction model using machine learning (ML) techniques. METHODS: A total of 462 patients with pathologically confirmed VCL were retrospectively collected and divided into low-risk and high-risk groups. We use a 5-fold cross validation method to ensure the generalization ability of the model built using the included dataset and avoid overfitting. Totally 504 texture features were extracted from each laryngoscope image. After feature selection, 10 ML classifiers were utilized to construct the model. The SHapley Additive exPlanations (SHAP) was employed for feature analysis. To evaluate the model, accuracy, sensitivity, specificity, and the area under the receiver operating characteristic (ROC) curve (AUC) were utilized. In addition, the model was transformed into an online application for public use and further tested in an independent dataset with 52 cases of VCL. RESULTS: A total of 12 features were finally selected, random forest (RF) achieved the best model performance, the mean accuracy, sensitivity, specificity, and AUC of the 5-fold cross validation were 92.2 ± 4.1%, 95.6 ± 4.0%, 85.8 ± 5.8%, and 90.7 ± 4.9%, respectively. The result is much higher than the clinicians (AUC between 63.1% and 75.2%). The SHAP algorithm ranks the importance of 12 texture features to the model. The test results of the additional independent datasets were 92.3%, 95.7%, 90.0%, and 93.3%, respectively. CONCLUSION: The proposed VCL risk stratification prediction model, which has been developed into a public online prediction platform, may be applied in practical clinical work. LEVEL OF EVIDENCE: 3 Laryngoscope, 2024.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA