Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Int J Legal Med ; 138(3): 781-786, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38030939

RESUMO

The identification of the type of body fluid in crime scene evidence may be crucial, so that the efforts are high to reduce the complexity of these analyses and to minimize time and costs. Reliable immunochromatographic rapid tests for specific and sensitive identification of blood, saliva, urine and sperm secretions are already routinely used in forensic genetics. The recently introduced Seratec® PMB test is said to detect not only hemoglobin, but also differentiate menstrual blood from other secretions containing blood (cells) by detecting D-dimers. In our experimental set-up, menstrual blood could be reliably detected in mock forensic samples. Here, the result was independent of sample age and extraction buffer volume. It was also successfully demonstrated that all secretions without blood cells were negative for both, hemoglobin (P) and D-dimer (M). However, several blood cell-containing secretions/tissues comprising blood (injury), nasal blood, postmortem blood and wound crust also demonstrated positive results for D-dimer (M) and were therefore false positives. For blood (injury) and nasal blood, this result was reproduced for different extraction buffer volumes. The results of this study clearly demonstrate that the Seratec® PMB test is neither useful nor suitable for use in forensic genetics because of the great risk of false positive results which can lead to false conclusions, especially in sexual offense or violent acts.


Assuntos
Líquidos Corporais , Sêmen , Humanos , Masculino , Sêmen/química , Líquidos Corporais/química , Saliva/química , Secreções Corporais/química , Hemoglobinas/análise , Genética Forense/métodos
2.
Adv Mater ; 36(13): e2309705, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38108547

RESUMO

Screening asymptomatic organisms (humans, animals, plants) with a high-diagnostic accuracy using point-of-care-testing (POCT) technologies, though still visionary holds great potential. Convenient surveillance requires easy-to-use, cost-effective, ultra-portable but highly reliable, in-vitro-diagnostic devices that are ready for use wherever they are needed. Currently, there are not yet such devices available on the market, but there are a couple more promising technologies developed at readiness-level 5: the Clustered-Regularly-Interspaced-Short-Palindromic-Repeats (CRISPR) lateral-flow-strip tests and the Single-Molecule-with-a-large-Transistor (SiMoT) bioelectronic palmar devices. They both hold key features delineated by the World-Health-Organization for POCT systems and an occurrence of false-positive and false-negative errors <1-5% resulting in diagnostic-selectivity and sensitivity >95-99%, while limit-of-detections are of few markers. CRISPR-strip is a molecular assay that, can detect down to few copies of DNA/RNA markers in blood while SiMoT immunometric and molecular test can detect down to a single oligonucleotide, protein marker, or pathogens in 0.1mL of blood, saliva, and olive-sap. These technologies can prospectively enable the systematic and reliable surveillance of asymptomatic ones prior to worsening/proliferation of illnesses allowing for timely diagnosis and swift prognosis. This could establish a proactive healthcare ecosystem that results in effective treatments for all living organisms generating diffuse and well-being at efficient costs.


Assuntos
Sistemas CRISPR-Cas , Saúde Única , Animais , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , RNA
3.
Trop Med Infect Dis ; 7(12)2022 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-36548682

RESUMO

The recombinant, modified leucine-rich repeat protein rhKU_Sej_LRR_2271 has been suggested as a candidate for leptospiral vaccine development since it was predicted to be a transmembrane protein containing leucine-rich repeat motifs and immunogenic epitopes. The immunogenic epitopes showed binding affinities with lower IC50 values than peptides of known antigenic proteins, e.g., LipL32. Moreover, this protein was immunoreactive with hyperimmune sera against several serovars. In this study, we aimed to develop a lateral flow strip test using the rhKU_Sej_LRR_2271 protein for the detection of anti-leptospiral IgG in dogs. The lateral flow assay was performed with 184 dog plasma samples and evaluated with a culture method, 16S ribosomal RNA gene (rss) analysis real-time PCR, and LipL32 ELISA. The culture method failed to detect leptospires in the dog blood samples. Six of nine symptomatic dogs gave positive results with the real-time PCR assay. The lateral flow assay and LipL32 ELISA gave positive results with 59 and 50 dogs, respectively. The sensitivity, specificity, and accuracy of the rhKU_Sej_LRR_2271 lateral flow strip test were 70.00, 82.09, and 78.80%, respectively, when compared with LipL32 ELISA. There was a significant association between the LipL32 ELISA and the rhKU_Sej_LRR_2271 lateral flow assay. The rhKU_Sej_LRR_2271 lateral flow strip test has therefore demonstrated a good potential to detect anti-leptospiral IgG in dogs.

4.
Viruses ; 14(8)2022 07 28.
Artigo em Inglês | MEDLINE | ID: mdl-36016279

RESUMO

Nipah virus (NiV) and Hendra virus (HeV) are classified as high-consequence zoonotic viruses characterized by high pathogenicity and high mortality in animals and humans. Rapid diagnosis is essential to containing the outbreak. In this study, the henipavirus receptor ephrin B2 was examined to determine whether it could be used as a universal ligand for henipavirus detection in immunoassays. Enzyme-linked immunosorbent assays (ELISAs) were developed using recombinant ephrin B2 as the capture ligand and two monoclonal antibodies (mAbs) as detection reagents. Using mAb F27NiV-34, which cross-reacts with NiV and HeV, we were able to detect NiV and HeV, while mAb F20NiV-65 was used to detect NiV. Therefore, using these two ELISAs, we were able to differentiate between NiV and HeV. Furthermore, we developed a rapid lateral flow strip test for NiV detection using ephrin B2 as the capture ligand combined with mAb F20NiV-65 as the detector. Taken together, our results show that the combination of ephrin B2 and a specific mAb provides an excellent pairing for NiV and HeV detection.


Assuntos
Vírus Hendra , Infecções por Henipavirus , Vírus Nipah , Orthopoxvirus , Animais , Anticorpos Monoclonais , Ensaio de Imunoadsorção Enzimática , Efrina-B2 , Infecções por Henipavirus/diagnóstico , Humanos , Ligantes
5.
Biosens Bioelectron ; 204: 114076, 2022 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-35180691

RESUMO

Pathogenic disease is an important factor affecting rice growth, yield and quality, and the development and application of rapid diagnostic methods will contribute to the prevention and control of rice disease. Herein, we developed a novel protospacer adjacent motif (PAM)-free loop-mediated isothermal amplification (LAMP) assisted CRISPR/Cas12a cleavage (Cas-PfLAMP) assay for detection of three rice pathogens; Xanthomonas oryzae pv. Oryzae (XOO), rice stripe virus (RSV), and rice black-streaked dwarf virus (RBSDV). The Cas-PfLAMP assay showed high specificity due to doubly specific recognition of LAMP primer sets and FnCas12a/sgRNA, and high sensitivity down to 9 or 3 copies due to LAMP amplification and CRISPR/Cas12a trans cleavage activity. Furthermore, a visual on-spot Cas-PfLAMP platform was established for detection of rice pathogens by combining solid-phase nucleic acid extraction and a lateral flow strip (LFS) test. Analysis of rice leaf field samples confirmed the impressive performance of the Cas-PfLAMP platform, demonstrating its suitability for rapid (∼50 min) on-spot detection of rice diseases. The assay could also be extended to detection of other plant diseases, and other nucleic acid field tests.


Assuntos
Técnicas Biossensoriais , Sistemas CRISPR-Cas , Sistemas CRISPR-Cas/genética , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos
6.
Talanta ; 233: 122540, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34215043

RESUMO

While lateral flow immunoassay (LFIA) is a simple technique that offers a rapid, robust, user friendly, and point-of-care test, its capacity for multiplex detection is rather limited. This study therefore combined the multiplexity of microarray technique and the simple and rapid characteristics of LFIA to enable simultaneous and quantitative detection of five mycotoxins, namely aflatoxin B1 (AFB1), deoxynivalenol (DON), fumonisin B1 (FUMB1), T-2 toxin (T-2), and zearalenone (ZON). In addition, we have synthesized a novel extra-large Stokes shift and strong fluorescence organic compound to be used as a reporter molecule which can be detected under UV light without light filter requirement. Many parameters including microarray spotting buffer, blocking buffer, and concentrations of mycotoxin antibodies were optimized for the microarray LFIA (µLFIA) construction. With the optimal conditions, the µLFIA could accurately and quantitatively detect multiple mycotoxins at the same time. The limits of detection of AFB1, DON, FUMB1, T-2, and ZON were 1.3, 0.5, 0.4, 0.4, and 0.9 ppb, respectively. The recoveries of these five mycotoxins were 70.7%-119.5% and 80.4%-124.8% for intra-assay and inter-assay, respectively. Combining the advantages of the novel reporter molecule and the multiplex capability of µLFIA test, this system could simultaneously detect multiple mycotoxins in one sample with high specificity and high sensitivity. Moreover, this system presents a promising affordable point-of-care platform to detect other analytes as well.


Assuntos
Micotoxinas , Zearalenona , Aflatoxina B1/análise , Contaminação de Alimentos/análise , Imunoensaio , Limite de Detecção , Micotoxinas/análise , Zearalenona/análise
7.
J Zhejiang Univ Sci B ; 20(2): 193-204, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30666851

RESUMO

In this work, a novel conjugate of ractopamine and bovine serum albumin (RAC-BSA) has been developed via the Mannich reaction, with a mole coupling ratio for RAC-BSA of 9:1. The proposed conjugation method provides a simple and one-step method with the use of fewer reagents compared with other conjugation methods for competitive immunoassays. RAC-BSA conjugation was used to fabricate a competitive lateral flow strip test for RAC detection in animal feed. For sample preparation, RAC was spiked in swine feed purchased from the local markets in Thailand, and methanol and running buffer at a volume ratio of 10:90 was used as extraction buffer. The procedures for sample preparation were completed within 25 min. Under optimal conditions, the limit of detection (LOD), assessed by the naked eye within 5 min, was found to be 1 ng/g. A semi-quantitative analysis was also conducted using a smart phone and computer software, with a linearity of 0.075-0.750 ng/g, calculated LOD of 0.10 ng/g, calculated limit of quantitation of 0.33 ng/g, and good correlation of 0.992. The recoveries were found in the range of 96.4%-103.7% with a relative standard deviation of 2.5%-3.6% for intra- and inter-assays. Comparison of the results obtained by the strip test with those obtained by enzyme-linked immunosorbent assay had a good agreement in terms of accuracy. Furthermore, this strip test exhibited highly specific RAC detection without cross reactivity with related compounds. Therefore, the RAC-BSA conjugation via the Mannich reaction can be accepted as a one-step and easy conjugation method and applied to the competitive lateral flow strip test.


Assuntos
Ração Animal/análise , Fenetilaminas/análise , Fitas Reagentes , Animais , Reações Cruzadas , Ensaio de Imunoadsorção Enzimática/métodos , Limite de Detecção , Fenetilaminas/química , Soroalbumina Bovina/química , Suínos
8.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-847066

RESUMO

In this work, a novel conjugate of ractopamine and bovine serum albumin (RAC–BSA) has been developed via the Mannich reaction, with a mole coupling ratio for RAC–BSA of 9:1. The proposed conjugation method provides a simple and one-step method with the use of fewer reagents compared with other conjugation methods for competitive immunoassays. RAC–BSA conjugation was used to fabricate a competitive lateral flow strip test for RAC detection in animal feed. For sample preparation, RAC was spiked in swine feed purchased from the local markets in Thailand, and methanol and running buffer at a volume ratio of 10:90 was used as extraction buffer. The procedures for sample preparation were completed within 25 min. Under optimal conditions, the limit of detection (LOD), assessed by the naked eye within 5 min, was found to be 1 ng/g. A semi-quantitative analysis was also conducted using a smart phone and computer software, with a linearity of 0.075–0.750 ng/g, calculated LOD of 0.10 ng/g, calculated limit of quantitation of 0.33 ng/g, and good correlation of 0.992. The recoveries were found in the range of 96.4%–103.7% with a relative standard deviation of 2.5%–3.6% for intra- and inter-assays. Comparison of the results obtained by the strip test with those obtained by enzyme-linked immunosorbent assay had a good agreement in terms of accuracy. Furthermore, this strip test exhibited highly specific RAC detection without cross reactivity with related compounds. Therefore, the RAC–BSA conjugation via the Mannich reaction can be accepted as a one-step and easy conjugation method and applied to the competitive lateral flow strip test.

9.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-1010451

RESUMO

In this work, a novel conjugate of ractopamine and bovine serum albumin (RAC-BSA) has been developed via the Mannich reaction, with a mole coupling ratio for RAC-BSA of 9:1. The proposed conjugation method provides a simple and one-step method with the use of fewer reagents compared with other conjugation methods for competitive immunoassays. RAC-BSA conjugation was used to fabricate a competitive lateral flow strip test for RAC detection in animal feed. For sample preparation, RAC was spiked in swine feed purchased from the local markets in Thailand, and methanol and running buffer at a volume ratio of 10:90 was used as extraction buffer. The procedures for sample preparation were completed within 25 min. Under optimal conditions, the limit of detection (LOD), assessed by the naked eye within 5 min, was found to be 1 ng/g. A semi-quantitative analysis was also conducted using a smart phone and computer software, with a linearity of 0.075-0.750 ng/g, calculated LOD of 0.10 ng/g, calculated limit of quantitation of 0.33 ng/g, and good correlation of 0.992. The recoveries were found in the range of 96.4%-103.7% with a relative standard deviation of 2.5%-3.6% for intra- and inter-assays. Comparison of the results obtained by the strip test with those obtained by enzyme-linked immunosorbent assay had a good agreement in terms of accuracy. Furthermore, this strip test exhibited highly specific RAC detection without cross reactivity with related compounds. Therefore, the RAC-BSA conjugation via the Mannich reaction can be accepted as a one-step and easy conjugation method and applied to the competitive lateral flow strip test.


Assuntos
Animais , Ração Animal/análise , Reações Cruzadas , Ensaio de Imunoadsorção Enzimática/métodos , Limite de Detecção , Fenetilaminas/química , Fitas Reagentes , Soroalbumina Bovina/química , Suínos
10.
J Agric Food Chem ; 65(37): 8248-8255, 2017 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-28844139

RESUMO

Group-specific monoclonal antibodies (Mabs) with selectivity for 27 sulfonamides were developed based on new combinations of immunogen and coating antigen. The Mab was able to recognize 27 sulfonamides with 50% inhibition concentration (IC50) values ranging from 0.15 to 15.38 µg/L. In particular, the IC50 values for five sulfonamides (sulfamethazine, sulfaquinoxaline, sulfamonomethoxine, sulfadimethoxine, and sulfamethoxazole) were 0.51, 0.15, 0.56, 0.54, and 2.14 µg/L, respectively. On the basis of the Mab, an immunochromatographic lateral flow strip test was established for rapid screening of sulfonamides in honey samples. The visual limit of detection of the strip test for most sulfonamides in spiked honey samples was below 10 µg/kg, satisfying the requirements of authorities. Positive honey and pork liver samples, which had been confirmed by high-performance liquid chromatography/mass spectrometry, were used to validate the reliability of the proposed strip test. The immunochromatographic lateral flow strip test provides a rapid and convenient method for fast screening of sulfonamides in honey samples.


Assuntos
Anti-Infecciosos/análise , Cromatografia de Afinidade/métodos , Contaminação de Alimentos/análise , Mel/análise , Fígado/química , Sulfonamidas/análise , Drogas Veterinárias/análise , Animais , Anti-Infecciosos/classificação , Anticorpos Monoclonais/análise , Cromatografia de Afinidade/instrumentação , Limite de Detecção , Suínos
11.
Acta Trop ; 141(Pt B): 198-203, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25225158

RESUMO

In Asia, Schistosoma japonicum is the predominant schistosome species, while Schistosoma mekongi is confined to limited foci in Cambodia and Lao People's Democratic Republic. While the People's Republic of China has been successful in controlling schistosomiasis, the disease remains a major public health issue in other areas. In order to prioritise intervention areas, not only accurate diagnosis is important but also other factors, such as practicality, time-efficiency and cost-effectiveness, since they strongly influence the success of control programmes. To evaluate the highly specific urine-based assays for the schistosome circulating cathodic antigen (CCA) and the circulating anodic antigen (CAA), banked urine samples from Cambodia (n=106) and the Philippines (n=43) were examined by the upconverted phosphor lateral flow (UCP-LF) CAA assay and the point-of-care (POC)-CCA urine assay. Based on 250 µl urine samples, UCP-LF CAA sensitivity outcomes surpassed a single stool examination by the Kato-Katz technique. The banked urine samples in the current study did not allow the evaluation of larger volumes, which conceivably should deliver considerably higher readings. The sensitivity of a single urine POC-CCA was in the same order as that of a single Kato-Katz thick smear examination, while the sensitivity approached that of triplicate Kato-Katz when a combination of both CAA and CCA assays was used. The promising results from the current proof-of-concept study call for larger investigations that will determine the accuracy of the urine-based CCA and CAA assays for S. mekongi and S. japonicum diagnosis.


Assuntos
Antígenos de Helmintos/urina , Proteínas de Helminto/urina , Schistosoma japonicum/imunologia , Esquistossomose Japônica/diagnóstico , Adolescente , Adulto , Idoso , Animais , Bancos de Espécimes Biológicos , Camboja , Criança , Pré-Escolar , Fezes/parasitologia , Humanos , Pessoa de Meia-Idade , Filipinas , Sistemas Automatizados de Assistência Junto ao Leito , Esquistossomose/diagnóstico , Esquistossomose/urina , Esquistossomose Japônica/urina , Sensibilidade e Especificidade , Adulto Jovem
12.
Exp Parasitol ; 135(2): 274-82, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23850995

RESUMO

UNLABELLED: An earlier reported laboratory assay, performed in The Netherlands, to diagnose Schistosoma infections by detection of the parasite antigen CAA in serum was converted to a more user-friendly format with dry reagents. The improved assay requires less equipment and allows storage and worldwide shipping at ambient temperature. Evaluation of the new assay format was carried out by local staff at Ampath Laboratories, South Africa. The lateral flow (LF) based assay utilized fluorescent ultrasensitive up-converting phosphor (UCP) reporter particles, to be read by a portable reader (UPlink) that was also provided to the laboratory. Over a period of 18 months, about 2000 clinical samples were analyzed prospectively in parallel with a routinely carried out CAA-ELISA. LF test results and ELISA data correlated very well at CAA concentrations above 300 pg/mL serum. At lower concentrations the UCP-LF test indicates a better performance than the ELISA. The UCP-LF strips can be stored as a permanent record as the UCP label does not fade. At the end of the 18 months testing period, LF strips were shipped back to The Netherlands where scan results obtained in South Africa were validated with different UCP scanning equipment including a novel, custom developed, small lightweight UCP strip reader (UCP-Quant), well suited for testing in low resource settings. CONCLUSION: The dry format UCP-LF assay was shown to provide a robust and easy to use format for rapid testing of CAA antigen in serum. It performed at least as good as the ELISA with respect to sensitivity and specificity, and was found to be superior with respect to speed and simplicity of use. Worldwide shipping at ambient temperature of the assay reagents, and the availability of small scanners to analyze the CAA UCP-LF strip, are two major steps towards point-of-care (POC) applications in remote and resource poor environments to accurately identify low (30 pg CAA/mL serum; equivalent to about 10 worm pairs) to heavy Schistosoma infections.


Assuntos
Antígenos de Helmintos/análise , Citometria de Fluxo/métodos , Glicoproteínas/análise , Proteínas de Helminto/análise , Schistosoma/imunologia , Esquistossomose/diagnóstico , Animais , Ensaio de Imunoadsorção Enzimática/normas , Citometria de Fluxo/normas , Humanos , Controle de Qualidade , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA