1.
Magn Reson Imaging ; 112: 128-135, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38986889

RESUMO

A multimodal brain function measurement system integrating functional magnetic resonance imaging (fMRI) and magnetoencephalography (MEG) is expected to be a tool that will provide new insights into neuroscience. To integrate fMRI and MEG, an ultra-low-field MRI (ULF-MRI) scanner that can generate a static magnetic field (B0) with an electromagnetic coil and turn off the B0 during MEG measurements is desirable. While electromagnetic B0 coil has the above advantages, it also has a trade-off between size and the broadness of the magnetic field homogeneity. In this study, we proposed a method for designing a B0 multi-stage circular coil arrangement that determines the number of coils required to maximize magnetic field homogeneity and minimize the total wiring length of the coils. The optimized multi-stage coil arrangement had an external shape of 600 mm in diameter and a maximum height of 600 mm, with an aperture of 600 mm in diameter and 300 mm in height. The magnetic field homogeneity was <100 ppm over a 210 mm diameter spherical volume (DSV). Compared to a previous two coil pairs arrangement with the same magnetic field homogeneity, the diameter was 1/1.9 times smaller, indicating that the newly designed B0 coil arrangement realized a smaller size and wider magnetic field homogeneity.

2.
Magn Reson Med ; 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38968093

RESUMO

PURPOSE: T1 mapping and T1-weighted contrasts have a complimentary but currently under utilized role in fetal MRI. Emerging clinical low field scanners are ideally suited for fetal T1 mapping. The advantages are lower T1 values which results in higher efficiency and reduced field inhomogeneities resulting in a decreased requirement for specialist tools. In addition the increased bore size associated with low field scanners provides improved patient comfort and accessibility. This study aims to demonstrate the feasibility of fetal brain T1 mapping at 0.55T. METHODS: An efficient slice-shuffling inversion-recovery echo-planar imaging (EPI)-based T1-mapping and postprocessing was demonstrated for the fetal brain at 0.55T in a cohort of 38 fetal MRI scans. Robustness analysis was performed and placental measurements were taken for validation. RESULTS: High-quality T1 maps allowing the investigation of subregions in the brain were obtained and significant correlation with gestational age was demonstrated for fetal brain T1 maps ( p < 0 . 05 $$ p<0.05 $$ ) as well as regions-of-interest in the deep gray matter and white matter. CONCLUSIONS: Efficient, quantitative T1 mapping in the fetal brain was demonstrated on a clinical 0.55T MRI scanner, providing foundations for both future research and clinical applications including low-field specific T1-weighted acquisitions.

3.
Surg Neurol Int ; 15: 218, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38974534

RESUMO

Background: Ultra-low-field magnetic resonance imaging (ULF-MRI) has emerged as an alternative with several portable clinical applications. This review aims to comprehensively explore its applications, potential limitations, technological advancements, and expert recommendations. Methods: A review of the literature was conducted across medical databases to identify relevant studies. Articles on clinical usage of ULF-MRI were included, and data regarding applications, limitations, and advancements were extracted. A total of 25 articles were included for qualitative analysis. Results: The review reveals ULF-MRI efficacy in intensive care settings and intraoperatively. Technological strides are evident through innovative reconstruction techniques and integration with machine learning approaches. Additional advantages include features such as portability, cost-effectiveness, reduced power requirements, and improved patient comfort. However, alongside these strengths, certain limitations of ULF-MRI were identified, including low signal-to-noise ratio, limited resolution and length of scanning sequences, as well as variety and absence of regulatory-approved contrast-enhanced imaging. Recommendations from experts emphasize optimizing imaging quality, including addressing signal-to-noise ratio (SNR) and resolution, decreasing the length of scan time, and expanding point-of-care magnetic resonance imaging availability. Conclusion: This review summarizes the potential of ULF-MRI. The technology's adaptability in intensive care unit settings and its diverse clinical and surgical applications, while accounting for SNR and resolution limitations, highlight its significance, especially in resource-limited settings. Technological advancements, alongside expert recommendations, pave the way for refining and expanding ULF-MRI's utility. However, adequate training is crucial for widespread utilization.

4.
Magn Reson Imaging ; 112: 107-115, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38971265

RESUMO

Low field MRI is safer and more cost effective than the high field MRI. One of the inherent problems of low field MRI is its low signal-to-noise ratio or sensitivity. In this work, we introduce a multimodal surface coil technique for signal excitation and reception to improve the RF magnetic field (B1) efficiency and potentially improve MR sensitivity. The proposed multimodal surface coil consists of multiple identical resonators that are electromagnetically coupled to form a multimodal resonator. The field distribution of its lowest frequency mode is suitable for MR imaging applications. The prototype multimodal surface coils are built, and the performance is investigated and validated through numerical simulation, standard RF measurements and tests, and comparison with the conventional surface coil at low fields. Our results show that the B1 efficiency of the multimodal surface coil outperforms that of the conventional surface coil which is known to offer the highest B1 efficiency among all coil categories, i.e., volume coil, half-volume coil and surface coil. In addition, in low-field MRI, the required low-frequency coils often use large value capacitance to achieve the low resonant frequency which makes frequency tuning difficult. The proposed multimodal surface coil can be conveniently tuned to the required low frequency for low-field MRI with significantly reduced capacitance value, demonstrating excellent low-frequency operation capability over the conventional surface coil.

5.
Radiography (Lond) ; 30(5): 1290-1296, 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39029278

RESUMO

INTRODUCTION: Diffusion-weighted imaging (DWI) with radial acquisition regime (RADAR; RADAR-DWI) is a fast spin echo (FSE)-based DWI imaging technique that is known to be robust to magnetic susceptibility artifacts and distortions as compared with echo planar imaging DWI (EPI-DWI). Several reports have suggested that the apparent diffusion coefficient (ADC) values obtained with FSE-based DWI are different from those obtained with EPI-DWI. The purpose of this study was to create phantoms that mimic the T2 and ADC values of various tissues and to demonstrate the ADC values obtained with RADAR-DWI and EPI-DWI in low-field magnetic resonance imaging (MRI) systems. METHODS: Several phantoms were created using sucrose and manganese (II) chloride tetrahydrate mimicking various tissues. RADAR-DWI and EPI-DWI were used to scan the phantoms, and the obtained ADC values were compared. RESULTS: The ADC values obtained with RADAR-DWI were significantly higher than those obtained with EPI-DWI for all phantoms (P < 0.05). The ADC values obtained by RADAR-DWI ranged from 0.70 ± 0.01 to 1.21 ± 0.02 ( × 10-3mm2s-1). Meanwhile, the ADC values obtained with EPI-DWI ranged from 0.59 ± 0.01 to 1.08 ± 0.05 ( × 10-3mm2s-1). CONCLUSIONS: We created phantoms mimicking T2 and ADC values of various tissues and demonstrated the differences in ADC values obtained with RADAR-DWI and EPI-DWI using low-field MRI systems. IMPLICATIONS FOR PRACTICE: ADC values obtained by RADAR-DWI are significantly higher than those obtained by EPI-DWI, with different cutoff values for various tumor malignancies between them.

6.
Dev Cogn Neurosci ; 69: 101397, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-39029330

RESUMO

Measures of physical growth, such as weight and height have long been the predominant outcomes for monitoring child health and evaluating interventional outcomes in public health studies, including those that may impact neurodevelopment. While physical growth generally reflects overall health and nutritional status, it lacks sensitivity and specificity to brain growth and developing cognitive skills and abilities. Psychometric tools, e.g., the Bayley Scales of Infant and Toddler Development, may afford more direct assessment of cognitive development but they require language translation, cultural adaptation, and population norming. Further, they are not always reliable predictors of future outcomes when assessed within the first 12-18 months of a child's life. Neuroimaging may provide more objective, sensitive, and predictive measures of neurodevelopment but tools such as magnetic resonance (MR) imaging are not readily available in many low and middle-income countries (LMICs). MRI systems that operate at lower magnetic fields (< 100mT) may offer increased accessibility, but their use for global health studies remains nascent. The UNITY project is envisaged as a global partnership to advance neuroimaging in global health studies. Here we describe the UNITY project, its goals, methods, operating procedures, and expected outcomes in characterizing neurodevelopment in sub-Saharan Africa and South Asia.

7.
MAGMA ; 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38967865

RESUMO

OBJECTIVE: To propose a deep learning-based low-field mobile MRI strategy for fast, high-quality, unshielded imaging using minimal hardware resources. METHODS: Firstly, we analyze the correlation of EMI signals between the sensing coil and the MRI coil to preliminarily verify the feasibility of active EMI shielding using a single sensing coil. Then, a powerful deep learning EMI elimination model is proposed, which can accurately predict the EMI components in the MRI coil signals using EMI signals from at least one sensing coil. Further, deep learning models with different task objectives (super-resolution and denoising) are strategically stacked for multi-level post-processing to enable fast and high-quality low-field MRI. Finally, extensive phantom and brain experiments were conducted on a home-built 0.2 T mobile brain scanner for the evaluation of the proposed strategy. RESULTS: 20 healthy volunteers were recruited to participate in the experiment. The results show that the proposed strategy enables the 0.2 T scanner to generate images with sufficient anatomical information and diagnostic value under unshielded conditions using a single sensing coil. In particular, the EMI elimination outperforms the state-of-the-art deep learning methods and numerical computation methods. In addition, 2 × super-resolution (DDSRNet) and denoising (SwinIR) techniques enable further improvements in imaging speed and quality. DISCUSSION: The proposed strategy enables low-field mobile MRI scanners to achieve fast, high-quality imaging under unshielded conditions using minimal hardware resources, which has great significance for the widespread deployment of low-field mobile MRI scanners.

8.
NMR Biomed ; : e5213, 2024 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-39032076

RESUMO

We aim to explore the feasibility of head and neck time-of-flight (TOF) magnetic resonance angiography (MRA) at ultra-low-field (ULF). TOF MRA was conducted on a highly simplified 0.05 T MRI scanner with no radiofrequency (RF) and magnetic shielding. A flow-compensated three-dimensional (3D) gradient echo (GRE) sequence with a tilt-optimized nonsaturated excitation RF pulse, and a flow-compensated multislice two-dimensional (2D) GRE sequence, were implemented for cerebral artery and vein imaging, respectively. For carotid artery and jugular vein imaging, flow-compensated 2D GRE sequences were utilized with venous and arterial blood presaturation, respectively. MRA was performed on young healthy subjects. Vessel-to-background contrast was experimentally observed with strong blood inflow effect and background tissue suppression. The large primary cerebral arteries and veins, carotid arteries, jugular veins, and artery bifurcations could be identified in both raw GRE images and maximum intensity projections. The primary brain and neck arteries were found to be reproducible among multiple examination sessions. These preliminary experimental results demonstrated the possibility of artery TOF MRA on low-cost 0.05 T scanners for the first time, despite the extremely low MR signal. We expect to improve the quality of ULF TOF MRA in the near future through sequence development and optimization, ongoing advances in ULF hardware and image formation, and the use of vascular T1 contrast agents.

9.
Talanta ; 278: 126550, 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-39013338

RESUMO

In this study, a low field nuclear magnetic resonance (LF-NMR) homogeneous sensor was constructed for detection of Escherichia coli (E. coli) based on the copper metabolism of E. coli triggered click reaction. When live E. coli was present, a large amount of Cu2+ ions were transformed into Cu+ via copper metabolism, which then catalyzed a Cu+-catalyzed azide-alkyne cycloaddition (CuAAC) reaction between two materials, azide group modified gadolinium oxide nanorods (Gd2O3-Az) and PA-GO@Fe3O4 i.e., graphene oxide (GO) loaded with large amounts of alkynyl (PA) groups and Fe3O4 nanoparticles simultaneously. After magnetic separation, unbound Gd2O3-Az was dissolved by added hydrochloric acid (HCl) to generate homogeneous Gd3+ solution, enabling homogeneous detection of E. coli. Triple signal amplification was achieved through the CuAAC reaction induced by E. coli copper metabolism, functional nanomaterials, and HCl assisted homogeneous detection. Under the optimal experimental conditions, the linear range and limit of detection (LOD) for E. coli were 10-1.0 × 107 CFU/mL and 3.5 CFU/mL, respectively, and the relative standard deviations (RSDs) were all less than 2.8 %. In addition, the sensor has satisfactory selectivity, stability and practical sample application capability, providing a new approach for the LF-NMR detection of food-borne pathogenic bacteria.

10.
Front Neurol ; 15: 1330203, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38854960

RESUMO

Ultra-low field (ULF) magnetic resonance imaging (MRI) holds the potential to make MRI more accessible, given its cost-effectiveness, reduced power requirements, and portability. However, signal-to-noise ratio (SNR) drops with field strength, necessitating imaging with lower resolution and longer scan times. This study introduces a novel Fourier-based Super Resolution (FouSR) approach, designed to enhance the resolution of ULF MRI images with minimal increase in total scan time. FouSR combines spatial frequencies from two orthogonal ULF images of anisotropic resolution to create an isotropic T2-weighted fluid-attenuated inversion recovery (FLAIR) image. We hypothesized that FouSR could effectively recover information from under-sampled slice directions, thereby improving the delineation of multiple sclerosis (MS) lesions and other significant anatomical features. Importantly, the FouSR algorithm can be implemented on the scanner with changes to the k-space trajectory. Paired ULF (Hyperfine SWOOP, 0.064 tesla) and high field (Siemens, Skyra, 3 Tesla) FLAIR scans were collected on the same day from a phantom and a cohort of 10 participants with MS or suspected MS (6 female; mean ± SD age: 44.1 ± 4.1). ULF scans were acquired along both coronal and axial planes, featuring an in-plane resolution of 1.7 mm × 1.7 mm with a slice thickness of 5 mm. FouSR was evaluated against registered ULF coronal and axial scans, their average (ULF average) and a gold standard SR (ANTs SR). FouSR exhibited higher SNR (47.96 ± 12.6) compared to ULF coronal (36.7 ± 12.2) and higher lesion conspicuity (0.12 ± 0.06) compared to ULF axial (0.13 ± 0.07) but did not exhibit any significant differences contrast-to-noise-ratio (CNR) compared to other methods in patient scans. However, FouSR demonstrated superior image sharpness (0.025 ± 0.0040) compared to all other techniques (ULF coronal 0.021 ± 0.0037, q = 5.9, p-adj. = 0.011; ULF axial 0.018 ± 0.0026, q = 11.1, p-adj. = 0.0001; ULF average 0.019 ± 0.0034, q = 24.2, p-adj. < 0.0001) and higher lesion sharpness (-0.97 ± 0.31) when compared to the ULF average (-1.02 ± 0.37, t(543) = -10.174, p = <0.0001). Average blinded qualitative assessment by three experienced MS neurologists showed no significant difference in WML and sulci or gyri visualization between FouSR and other methods. FouSR can, in principle, be implemented on the scanner to produce clinically useful FLAIR images at higher resolution on the fly, providing a valuable tool for visualizing lesions and other anatomical structures in MS.

11.
Sensors (Basel) ; 24(12)2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38931494

RESUMO

Due to limitations in current motion tracking technologies and increasing interest in alternative sensors for motion tracking both inside and outside the MRI system, in this study we share our preliminary experience with three alternative sensors utilizing diverse technologies and interactions with tissue to monitor motion of the body surface, respiratory-related motion of major organs, and non-respiratory motion of deep-seated organs. These consist of (1) a Pilot-Tone RF transmitter combined with deep learning algorithms for tracking liver motion, (2) a single-channel ultrasound transducer with deep learning for monitoring bladder motion, and (3) a 3D Time-of-Flight camera for observing the motion of the anterior torso surface. Additionally, we demonstrate the capability of these sensors to simultaneously capture motion data outside the MRI environment, which is particularly relevant for procedures like radiation therapy, where motion status could be related to previously characterized cyclical anatomical data. Our findings indicate that the ultrasound sensor can track motion in deep-seated organs (bladder) as well as respiratory-related motion. The Time-of-Flight camera offers ease of interpretation and performs well in detecting surface motion (respiration). The Pilot-Tone demonstrates efficacy in tracking bulk respiratory motion and motion of major organs (liver). Simultaneous use of all three sensors could provide complementary motion information outside the MRI bore, providing potential value for motion tracking during position-sensitive treatments such as radiation therapy.


Assuntos
Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Respiração , Fígado/diagnóstico por imagem , Fígado/fisiologia , Movimento/fisiologia , Bexiga Urinária/diagnóstico por imagem , Bexiga Urinária/fisiologia , Algoritmos , Aprendizado Profundo , Movimento (Física) , Ultrassonografia/métodos
12.
Magn Reson Med ; 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38888139

RESUMO

PURPOSE: To introduce an alternative idea for fat suppression that is suited both for low-field applications where conventional fat-suppression approaches become ineffective due to narrow spectral separation and for applications with strong B0 homogeneities. METHODS: Separation of fat and water is achieved by sweeping the frequency of RF saturation pulses during continuous radial acquisition and calculating frequency-resolved images using regularized iterative reconstruction. Voxel-wise signal-response curves are extracted that reflect tissue's response to RF saturation at different frequencies and allow the classification into fat or water. This information is then utilized to generate water-only composite images. The principle is demonstrated in free-breathing abdominal and neck examinations using stack-of-stars 3D balanced SSFP (bSSFP) and gradient-recalled echo (GRE) sequences at 0.55 and 3T. Moreover, a potential extension toward quantitative fat/water separation is described. RESULTS: Experiments with a proton density fat fraction (PDFF) phantom validated the reliability of fat/water separation using signal-response curves. As demonstrated for abdominal imaging at 0.55T, the approach resulted in more uniform fat suppression without loss of water signal and in improved CSF-to-fat signal ratio. Moreover, the approach provided consistent fat suppression in 3T neck exams where conventional spectrally-selective fat saturation failed due to strong local B0 inhomogeneities. The feasibility of simultaneous fat/water quantification has been demonstrated in a PDFF phantom. CONCLUSION: The proposed principle achieves reliable fat suppression in low-field applications and adapts to high-field applications with strong B0 inhomogeneity. Moreover, the principle potentially provides a basis for developing an alternative approach for PDFF quantification.

13.
Sensors (Basel) ; 24(11)2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38894142

RESUMO

Inline analytics in industrial processes reduce operating costs and production rejection. Dedicated sensors enable inline process monitoring and control tailored to the application of interest. Nuclear Magnetic Resonance is a well-known analytical technique but needs adapting for low-cost, reliable and robust process monitoring. A V-shaped low-field NMR sensor was developed for inline process monitoring and allows non-destructive and non-invasive measurements of materials, for example in a pipe. In this paper, the industrial application is specifically devoted to the quality control of anode slurries in battery production. The characterization of anode slurries was performed with the sensor to determine chemical composition and detect gas inclusions. Additionally, flow properties play an important role in continuous production processes. Therefore, the in- and outflow effects were investigated with the V-shaped NMR sensor as a basis for the future determination of slurry flow fields.

14.
Food Chem ; 458: 140093, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38943960

RESUMO

This study evaluated the effects of postharvest ripening (0-6 days, D0-6) on cell wall pectin profile, infrared-assisted hot air-drying characteristics, and sugar content. Results showed that during postharvest ripening progress, the content of water-soluble pectin (WSP) and chelate-soluble pectin (CSP) increased while the content of Na2CO3-soluble pectin (NSP) and hemicellulose (HC) decreased. In addition, the average molecular weight of WSP increased while the average molecular weight of NSP decreased. Secondly, the drying time of plums with different postharvest ripening periods was in the order: D3 < D4 < D2 < D1 < D0 < D5 < D6. Furthermore, the sugar content of dried plums was mainly influenced by drying time, with three stages of sugar changes observed, tied to moisture content: (1) Sucrose hydrolyzes (50-85%); (2) Fructose and glucose degrade (15-50%); (3) Sorbitol degrades (15-42%). These findings indicate that the transformation of cell wall pectin profile during the postharvest ripening process alters drying behavior and regulates the sugar content of dried plums. CHEMICAL COMPOUNDS STUDIED IN THIS ARTICLE: Galacturonic acid (PubChem CID: 439215); Acetone (PubChem CID: 180); Distilled water (PubChem CID: 962); Trans-1,2-Diaminocyclohexane-N, N, N, N'-tetraacetic acid (PubChem CID: 2723845); Na2CO3 (PubChem CID: 10340); Glucose (PubChem CID: 5793); fructose (PubChem CID: 2723872) sucrose (PubChem CID: 5988) sorbitol (PubChem CID: 5780) and Sodium borohydride (PubChem CID: 4311764).

15.
J Food Sci ; 89(7): 4276-4285, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38837399

RESUMO

Avocado oil is a nutritious, edible oil produced from avocado fruit. It has high commercial value and is increasing in popularity, thus powerful analytical methods are needed to ensure its quality and authenticity. Recent advancements in low-field (LF) NMR spectroscopy allow for collection of high-quality data despite the use of low magnetic fields produced by non-superconductive magnets. Combined with chemometrics, LF NMR opens new opportunities in food analysis using targeted and untargeted approaches. Here, it was used to determine poly-, mono-, and saturated fatty acids in avocado oil. Although direct signal integration of LF NMR spectra was able to determine certain classes of fatty acids, it had several challenges arising from signal overlapping. Thus, we used partial least square regression and developed models with good prediction performance for fatty acid composition, with residual prediction deviation ranging 3.46-5.53 and root mean squared error of prediction CV ranging 0.46-2.48. In addition, LF NMR, combined with unsupervised and supervised methods, enabled the differentiation of avocado oil from other oils, namely, olive oil, soybean oil, canola oil, high oleic (OL) safflower oil, and high OL sunflower oil. This study showed that LF NMR can be used as an efficient alternative for the compositional analysis and authentication of avocado oil. PRACTICAL APPLICATION: Here, we describe the application of LF-NMR for fatty acid analysis and avocado oil authentication. LF-NMR can be an efficient tool for targeted and untargeted analysis, thus becoming an attractive option for companies, regulatory agencies, and quality control laboratories. This tool is especially important for organizations and entities seeking economic, user-friendly, and sustainable analysis solutions.


Assuntos
Ácidos Graxos , Espectroscopia de Ressonância Magnética , Persea , Óleos de Plantas , Persea/química , Espectroscopia de Ressonância Magnética/métodos , Óleos de Plantas/química , Óleos de Plantas/análise , Ácidos Graxos/análise , Quimiometria/métodos , Análise de Alimentos/métodos , Frutas/química
16.
Magn Reson Med ; 92(4): 1511-1524, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38872384

RESUMO

PURPOSE: To develop and validate a highly efficient motion compensated free-breathing isotropic resolution 3D whole-heart joint T1/T2 mapping sequence with anatomical water/fat imaging at 0.55 T. METHODS: The proposed sequence takes advantage of shorter T1 at 0.55 T to acquire three interleaved water/fat volumes with inversion-recovery preparation, no preparation, and T2 preparation, respectively. Image navigators were used to facilitate nonrigid motion-compensated image reconstruction. T1 and T2 maps were jointly calculated by a dictionary matching method. Validations were performed with simulation, phantom, and in vivo experiments on 10 healthy volunteers and 1 patient. The performance of the proposed sequence was compared with conventional 2D mapping sequences including modified Look-Locker inversion recovery and T2-prepared balanced steady-SSFP sequence. RESULTS: The proposed sequence has a good T1 and T2 encoding sensitivity in simulation, and excellent agreement with spin-echo reference T1 and T2 values was observed in a standardized T1/T2 phantom (R2 = 0.99). In vivo experiments provided good-quality co-registered 3D whole-heart T1 and T2 maps with 2-mm isotropic resolution in a short scan time of about 7 min. For healthy volunteers, left-ventricle T1 mean and SD measured by the proposed sequence were both comparable with those of modified Look-Locker inversion recovery (640 ± 35 vs. 630 ± 25 ms [p = 0.44] and 49.9 ± 9.3 vs. 54.4 ± 20.5 ms [p = 0.42]), whereas left-ventricle T2 mean and SD measured by the proposed sequence were both slightly lower than those of T2-prepared balanced SSFP (53.8 ± 5.5 vs. 58.6 ± 3.3 ms [p < 0.01] and 5.2 ± 0.9 vs. 6.1 ± 0.8 ms [p = 0.03]). Myocardial T1 and T2 in the patient measured by the proposed sequence were in good agreement with conventional 2D sequences and late gadolinium enhancement. CONCLUSION: The proposed sequence simultaneously acquires 3D whole-heart T1 and T2 mapping with anatomical water/fat imaging at 0.55 T in a fast and efficient 7-min scan. Further investigation in patients with cardiovascular disease is now warranted.


Assuntos
Tecido Adiposo , Imageamento Tridimensional , Imagens de Fantasmas , Humanos , Imageamento Tridimensional/métodos , Masculino , Tecido Adiposo/diagnóstico por imagem , Adulto , Coração/diagnóstico por imagem , Reprodutibilidade dos Testes , Algoritmos , Feminino , Imageamento por Ressonância Magnética/métodos , Respiração , Água Corporal/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Voluntários Saudáveis
17.
Magn Reson Med ; 92(4): 1649-1657, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38725132

RESUMO

PURPOSE: To investigate the feasibility of diffusion tensor brain imaging at 0.55T with comparisons against 3T. METHODS: Diffusion tensor imaging data with 2 mm isotropic resolution was acquired on a cohort of five healthy subjects using both 0.55T and 3T scanners. The signal-to-noise ratio (SNR) of the 0.55T data was improved using a previous SNR-enhancing joint reconstruction method that jointly reconstructs the entire set of diffusion weighted images from k-space using shared-edge constraints. Quantitative diffusion tensor parameters were estimated and compared across field strengths. We also performed a test-retest assessment of repeatability at each field strength. RESULTS: After applying SNR-enhancing joint reconstruction, the diffusion tensor parameters obtained from 0.55T data were strongly correlated ( R 2 ≥ 0 . 70 $$ {R}^2\ge 0.70 $$ ) with those obtained from 3T data. Test-retest analysis showed that SNR-enhancing reconstruction improved the repeatability of the 0.55T diffusion tensor parameters. CONCLUSION: High-resolution in vivo diffusion MRI of the human brain is feasible at 0.55T when appropriate noise-mitigation strategies are applied.


Assuntos
Encéfalo , Imagem de Tensor de Difusão , Estudos de Viabilidade , Processamento de Imagem Assistida por Computador , Razão Sinal-Ruído , Humanos , Encéfalo/diagnóstico por imagem , Imagem de Tensor de Difusão/métodos , Masculino , Adulto , Reprodutibilidade dos Testes , Feminino , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Voluntários Saudáveis
19.
Molecules ; 29(9)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38731577

RESUMO

Recently, benchtop nuclear magnetic resonance (NMR) spectrometers utilizing permanent magnets have emerged as versatile tools with applications across various fields, including food and pharmaceuticals. Their efficacy is further enhanced when coupled with chemometric methods. This study presents an innovative approach to leveraging a compact benchtop NMR spectrometer coupled with chemometrics for screening honey-based food supplements adulterated with active pharmaceutical ingredients. Initially, fifty samples seized by French customs were analyzed using a 60 MHz benchtop spectrometer. The investigation unveiled the presence of tadalafil in 37 samples, sildenafil in 5 samples, and a combination of flibanserin with tadalafil in 1 sample. After conducting comprehensive qualitative and quantitative characterization of the samples, we propose a chemometric workflow to provide an efficient screening of honey samples using the NMR dataset. This pipeline, utilizing partial least squares discriminant analysis (PLS-DA) models, enables the classification of samples as either adulterated or non-adulterated, as well as the identification of the presence of tadalafil or sildenafil. Additionally, PLS regression models are employed to predict the quantitative content of these adulterants. Through blind analysis, this workflow allows for the detection and quantification of adulterants in these honey supplements.


Assuntos
Suplementos Nutricionais , Mel , Espectroscopia de Ressonância Magnética , Mel/análise , Suplementos Nutricionais/análise , Espectroscopia de Ressonância Magnética/métodos , Citrato de Sildenafila/análise , Fluxo de Trabalho , Quimiometria/métodos , Tadalafila/análise , Análise dos Mínimos Quadrados , Contaminação de Medicamentos/prevenção & controle , Análise Discriminante
20.
Front Neurol ; 15: 1339223, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38585353

RESUMO

Background: Portable low-field-strength magnetic resonance imaging (MRI) systems represent a promising alternative to traditional high-field-strength systems with the potential to make MR technology available at scale in low-resource settings. However, lower image quality and resolution may limit the research and clinical potential of these devices. We tested two super-resolution methods to enhance image quality in a low-field MR system and compared their correspondence with images acquired from a high-field system in a sample of young people. Methods: T1- and T2-weighted structural MR images were obtained from a low-field (64mT) Hyperfine and high-field (3T) Siemens system in N = 70 individuals (mean age = 20.39 years, range 9-26 years). We tested two super-resolution approaches to improve image correspondence between images acquired at high- and low-field: (1) processing via a convolutional neural network ('SynthSR'), and (2) multi-orientation image averaging. We extracted brain region volumes, cortical thickness, and cortical surface area estimates. We used Pearson correlations to test the correspondence between these measures, and Steiger Z tests to compare the difference in correspondence between standard imaging and super-resolution approaches. Results: Single pairs of T1- and T2-weighted images acquired at low field showed high correspondence to high-field-strength images for estimates of total intracranial volume, surface area cortical volume, subcortical volume, and total brain volume (r range = 0.60-0.88). Correspondence was lower for cerebral white matter volume (r = 0.32, p = 0.007, q = 0.009) and non-significant for mean cortical thickness (r = -0.05, p = 0.664, q = 0.664). Processing images with SynthSR yielded significant improvements in correspondence for total brain volume, white matter volume, total surface area, subcortical volume, cortical volume, and total intracranial volume (r range = 0.85-0.97), with the exception of global mean cortical thickness (r = 0.14). An alternative multi-orientation image averaging approach improved correspondence for cerebral white matter and total brain volume. Processing with SynthSR also significantly improved correspondence across widespread regions for estimates of cortical volume, surface area and subcortical volume, as well as within isolated prefrontal and temporal regions for estimates of cortical thickness. Conclusion: Applying super-resolution approaches to low-field imaging improves regional brain volume and surface area accuracy in young people. Finer-scale brain measurements, such as cortical thickness, remain challenging with the limited resolution of low-field systems.