1.
Front Bioeng Biotechnol ; 12: 1421714, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39086499

RESUMO

Acute ischemic stroke caused by large vessel occlusions is being increasingly treated with neurovascular interventions. The hemodynamics within the collateral system of the circle of Willis (CoW) hemodynamics play a fundamental role in therapy success. However, transient in vivo data on pathological collateral flow during large vessel occlusions are not available. Moreover, there are no flow models that accurately simulate the hemodynamic conditions in the CoW during large vessel occlusions. We used a circulatory loop to generate highly reproducible cerebrovascular-like flows and pressures and used non-invasive flow visualization and high-resolution flow and pressure measurements to acquire detailed, time-dependent hemodynamics inside an anatomical phantom of the CoW. After calibrating a physiological reference case, we induced occlusions in the 1. middle cerebral artery, 2. terminal carotid artery, and 3. basilar artery; and measured the left posterior communicating artery flow. Mean arterial pressure and pulse pressure remained unchanged in the different occlusion cases compared to the physiological reference case, while total cerebral flow decreased by up to 19%. In all three occlusion cases, reversed flow was found in the left posterior communicating artery compared to the reference case with different flow magnitudes and pulsatility index values. The experimental results were compared with clinical findings, demonstrating the capability of this realistic cerebrovascular flow setup. This novel cerebrovascular flow setup opens the possibility for investigating different topics of neurovascular interventions under various clinical conditions in controlled preclinical laboratory studies.

2.
Ann Biomed Eng ; 2024 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-39103737

RESUMO

PURPOSE: To investigate the effect of changing systolic and diastolic blood pressures (SBP and DBP, respectively) on sinus flow and valvular and epicardial coronary flow dynamics after TAVR and SAVR. METHODS: SAPIEN 3 and Magna valves were deployed in an idealized aortic root model as part of a pulse duplicating left heart flow loop simulator. Different combinations of SBP and DBP were applied to the test setup and the resulting change in total coronary flow from baseline (120/60 mmHg), effective orifice area (EOA), and left ventricular (LV) workload, with each combination, was assessed. In addition, particle image velocimetry was used to assess the Laplacian of pressure ( ∇ 2 P ) in the sinus, coronary and main flow velocities, the energy dissipation rate (EDR) in the sinus and the LV workload. RESULTS: This study shows that under an elevated SBP, there is an increase in the total coronary flow, EOA, LV workload, peak velocities downstream of the valve, ∇ 2 P , and EDR. With an elevated DBP, there was an increase in the total coronary flow and ∇ 2 P . However, EOA and LV workload decreased with an increase in DBP, and EDR increased with a decrease in DBP. CONCLUSIONS: Blood pressure alters the hemodynamics in the sinus and downstream flow following aortic valve replacement, potentially influencing outcomes in some patients.

3.
Artif Organs ; 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38957988

RESUMO

BACKGROUND: The Food and Drug Administration (FDA) blood pump is an open-source benchmark cardiovascular device introduced for validating computational and experimental performance analysis tools. The time-resolved velocity field for the whole impeller has not been established, as is undertaken in this particle image velocimetry (PIV) study. The level of instantaneous velocity fluctuations is important, to assess the flow-induced rotor vibrations which may contribute to the total blood damage. METHODS: To document these factors, time-resolved two-dimensional PIV experiments were performed that were precisely phase-locked with the impeller rotation angle. The velocity fields in the impeller and in the volute conformed with the previous single blade passage experiments of literature. RESULTS: Depending on the impeller orientation, present experiments showed that volute outlet nozzle flow can fluctuate up to 34% during impeller rotation, with a maximum standard experimental uncertainty of 2.2%. Likewise, the flow fields in each impeller passage also altered in average 33.5%. Considerably different vortex patterns were observed for different blade passages, with the largest vortical structures reaching an average core radii of 7 mm. The constant volute area employed in the FDA pump design contributes to the observed velocity imbalance, as illustrated in our velocity measurements. CONCLUSIONS: By introducing the impeller orientation parameter for the nozzle flow, this study considers the possible uncertainties influencing pump flow. Expanding the available literature data, analysis of inter-blade relative velocity fields is provided here for the first-time to the best of our knowledge. Consequently, our research fills a critical knowledge gap in the understanding of the flow dynamics of an important benchmark cardiovascular device. This study prompts the need for improved hydrodynamic designs and optimized devices to be used as benchmark test devices, to build more confidence and safety in future ventricular assist device performance assessment studies.

4.
JTCVS Open ; 19: 61-67, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39015440

RESUMO

Objective: The use of the transcatheter aortic valve in low-risk patients might lead to a second intervention due to the deterioration of the first 1. Understanding the implantation height is key to an effective redo transcatheter aortic valve replacement treatment. Methods: The effects of implantation height on the performance of a balloon-expandable valve within a self-expandable valve were assessed using hemodynamic testing and particle image velocimetry. The hemodynamic performances, leaflet kinematics, and turbulent shear stresses were measured and compared. Results: When a second balloon-expandable valve was positioned at varying heights relative to the first self-expandable valve, the leaflet motion of the first valve transitioned from free opening and closing to overhanging, and eventually to being entirely pinned to the stent, forming a neo-skirt. When the leaflets of the self-expandable valve could move freely, a decrease in regurgitation fraction was observed, but with an increased pressure gradient across the valve. Flow visualization indicated that the overhanging leaflets disrupted the flow, generating a higher level of turbulence. Conclusions: This study suggests that the overhanging leaflets should be avoided, whereas the other 2 scenarios should be carefully evaluated based on an individual patient's anatomy and the cause of failure of the first valve.

5.
Front Cardiovasc Med ; 11: 1432784, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39026997

RESUMO

Introduction: Primary pulmonary vein stenosis (PVS) is a rare congenital heart disease that proves to be a clinical challenge due to the rapidly progressive disease course and high rates of treatment complications. PVS intervention is frequently faced with in-stent restenosis and persistent disease progression despite initial venous recanalization with balloon angioplasty or stenting. Alterations in wall shear stress (WSS) have been previously associated with neointimal hyperplasia and venous stenosis underlying PVS progression. Thus, the development of patient-specific three-dimensional (3D) in vitro models is needed to further investigate the biomechanical outcomes of endovascular and surgical interventions. Methods: In this study, deidentified computed tomography images from three patients were segmented to generate perfusable phantom models of pulmonary veins before and after catheterization. These 3D reconstructions were 3D printed using a clear resin ink and used in a benchtop experimental setup. Computational fluid dynamic (CFD) analysis was performed on models in silico utilizing Doppler echocardiography data to represent the in vivo flow conditions at the inlets. Particle image velocimetry was conducted using the benchtop perfusion setup to analyze WSS and velocity profiles and the results were compared with those predicted by the CFD model. Results: Our findings indicated areas of undesirable alterations in WSS before and after catheterization, in comparison with the published baseline levels in the healthy in vivo tissues that may lead to regional disease progression. Discussion: The established patient-specific 3D in vitro models and the developed in vitro-in silico platform demonstrate great promise to refine interventional approaches and mitigate complications in treating patients with primary PVS.

6.
J Exp Biol ; 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39022908

RESUMO

Complex hydrodynamics abound in natural streams, yet the selective pressures these impose upon different size classes of fish are not well understood. Attached vortices are produced by relatively large objects that block freestream flow, which fish routinely utilize for flow refuging. To test how flow refuging and the potential harvesting of energy (as seen in Kármán gaiting) varies across size classes in rainbow trout (Oncorhynchus mykiss; fingerling, 8 cm; parr, 14 cm; adult, 21 cm; n=4 per size class), we used a water flume (4,100 L; freestream flow at 65 cm s-1) and created vortices using 45° wing dams of varying size (small=15 cm, medium=31 cm, large=48 cm). We monitored microhabitat selection and swimming kinematics of individual trout and measured the flow field in the wake of wing dams using time-resolved Particle Image Velocimetry (PIV). Trout of each size class preferentially swam in vortices rather than the freestream, but the capacity to flow refuge varied according to the ratio of vortex width to fish length (VW : FL). Consistent refuging behavior was exhibited when VW : FL> 1.5. All size classes exhibited increased wavelength and Strouhal number and decreased tail beat frequency within vortices compared with freestream, suggesting that swimming in vortices requires less power output. In 17% of the trials, fish preferentially swam in a manner that suggests energy harvesting from the shear layer. Our results can inform efforts toward riparian restoration and fishway design to improve salmonid conservation.

7.
Entropy (Basel) ; 26(7)2024 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-39056935

RESUMO

In particle image velocimetry (PIV) experiments, background noise inevitably exists in the particle images when a particle image is being captured or transmitted, which blurs the particle image, reduces the information entropy of the image, and finally makes the obtained flow field inaccurate. Taking a low-quality original particle image as the research object in this research, a frequency domain processing method based on wavelet decomposition and reconstruction was applied to perform particle image pre-processing. Information entropy analysis was used to evaluate the effect of image processing. The results showed that useful high-frequency particle information representing particle image details in the original particle image was effectively extracted and enhanced, and the image background noise was significantly weakened. Then, information entropy analysis of the image revealed that compared with the unprocessed original particle image, the reconstructed particle image contained more effective details of the particles with higher information entropy. Based on reconstructed particle images, a more accurate flow field can be obtained within a lower error range.

8.
Front Neurol ; 15: 1364105, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38831781

RESUMO

Background: Understanding the risk factors leading to intracranial aneurysm (IA) rupture have still not been fully clarified. They are vital for proper medical guidance of patients harboring unruptured IAs. Clarifying the hemodynamics associated with the point of rupture could help could provide useful information about some of the risk factors. Thus far, few studies have studied this issue with often diverging conclusions. Methods: We identified a point of rupture in patients operated for an IAs during surgery, using a combination of preoperative computed tomography (CT) and computed tomography angiography (CTA). Hemodynamic parameters were calculated both for the aneurysm sac as a whole and the point of rupture. In two cases, the results of CFD were compared with those of the experiment using particle image velocimetry (PIV). Results: We were able to identify 6 aneurysms with a well-demarcated point of rupture. In four aneurysms, the rupture point was near the vortex with low wall shear stress (WSS) and high oscillatory shear index (OSI). In one case, the rupture point was in the flow jet with high WSS. In the last case, the rupture point was in the significant bleb and no specific hemodynamic parameters were found. The CFD results were verified in the PIV part of the study. Conclusion: Our study shows that different hemodynamic scenarios are associated with the site of IA rupture. The numerical simulations were confirmed by laboratory models. This study further supports the hypothesis that various pathological pathways may lead to aneurysm wall damage resulting in its rupture.

9.
Fundam Res ; 4(2): 334-343, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38933520

RESUMO

By conducting a two-dimensional experimental study, this paper aims to enhance the understanding of the mechanism of sand convective motions in the vicinity of a wall subjected to long-term cyclic lateral loadings. The experimental tests were conducted in a rectangular sandbox with a transparent front-wall, through which the process of sand particle motions could be recorded by using a high-resolution digital camera. The images were processed with a high time-resolved PIV (Particle Image Velocimetry) system. Based on the experimental data, this work (1) presents the sand flow field in the convective zones; (2) provides means to describe the convection mechanism; (3) proposes the relationships between the loading conditions and dimensions of the region with intense sand movement; and (4) elaborates the similarity of the sand flow velocity structure within the sand convective zones.

10.
ACS Appl Mater Interfaces ; 16(26): 34313-34325, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38907697

RESUMO

Boiling heat transfer has a high thermal efficiency by latent heat absorption, which makes it an attractive process for cooling electronic device chips. Critical heat flux (CHF), the maximum heat flux, is a crucial factor determining the operating range of the boiling applications. The CHF can be enhanced by improving the fluid supply to the boiling surface. Herein, micropillar interfacial surfaces have been proposed to increase the CHF by increasing the rewetting flow, which determines the fluid-supply capacity near the bubble contact line. A state-of-art two-phase particle image velocimetry (two-phase PIV) technique is introduced for rewetting flow measurement on micropillar structures (MPSs) to analyze the CHF-enhancement mechanism. The two-phase PIV visualization setup offers high spatial (∼120 µm) and temporal (∼2000 Hz) resolutions for measuring rewetting flow during bubble growth. The MPS samples exhibit enhanced CHF and rewetting flows compared to those on a plain surface. The roughest case, D04G10 sample, had a CHF of 164 W/cm2, 1.84 times higher than that of the plain surface. The D04G10 sample also recorded the highest rewetting velocity of 0.311 m/s, 4.7 times higher than that of the plain surface. The comparison between the rewetting flow and wicking performance shows that wicking-induced flow accounted for a substantial part (∼17%) of the rewetting flow and contributed significantly to the CHF enhancement owing to large rewetting flow by delaying vapor-film formation. Based on these findings, a new CHF model suggested by introducing the rewetting parameter shows a high CHF prediction accuracy of 94%.

11.
JSES Int ; 8(3): 570-576, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38707573

RESUMO

Background: The relationship between lower mobility, as measured by the elbow forward translation motion (T-motion) test, a new indicator of shoulder joint complex movement that measures elbow position when both dorsal hands are placed on the iliac crest while in a sitting position, and the parameters calculated by ultrasonography is unknown. The purpose of this study was to investigate the limiting factors of T-motion through motion analysis of the humeral head and rotator cuff muscles using ultrasonography in college baseball players. Methods: Thirteen college baseball players participated in this cross-sectional study. The shortest distance from the posterior edge of the glenoid to the humeral head was measured in the static and T-motion positions, and the difference was calculated as the humeral head translation. The velocity of the infraspinatus was calculated during shoulder internal/external rotation using the particle image velocimetry method. These parameters were compared between the throwing and nonthrowing sides to examine the limiting factors of T-motion. Results: This study indicated moderate-to-good reliability for the parameters calculated by ultrasonography. The mean anterior translation distance was significantly greater on the throwing side than on the nonthrowing side (r = 0.56, P = .015). The mean velocity of infraspinatus during internal rotation was significantly lower on the throwing side than on the nonthrowing side (r = 0.51, P = .028). Conclusion: Increased anterior translation of the humeral head and decreased the velocity of infraspinatus are likely correlated with reduced T-motion mobility in college baseball players. These methods showed potential for physical therapy assessment and intervention to prevent shoulder dysfunction.

12.
Front Med Technol ; 6: 1376649, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38756328

RESUMO

This study aims to evaluate the fluid dynamic characteristics of the VenusP Valve System™ under varying cardiac outputs in vitro. A thorough hemodynamic study of the valve under physiological cardiac conditions was conducted and served as an independent assessment of the performance of the valve. Flow fields downstream of the valve near the pulmonary bifurcation were quantitatively studied by two-dimensional Particle Image Velocimetry (PIV). The obtained flow field was analyzed for potential regions of flow stasis and recirculation, and elevated shear stress and turbulence. High-speed en face imaging capturing the leaflet motion provided data for leaflet kinematic modeling. The experimental conditions for PIV studies were in accordance with ISO 5840-1:2021 standard, and two valves with different lengths and different orientations were studied. Results show good hemodynamics performance for the tested valves according to ISO 5840 standard without significant regions of flow stasis. Observed shear stress values are all well below established hemolysis limits.

13.
J Med Imaging (Bellingham) ; 11(3): 037001, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38765874

RESUMO

Purpose: To investigate the accuracy of high-framerate echo particle image velocimetry (ePIV) and computational fluid dynamics (CFD) for determining velocity vectors in femoral bifurcation models through comparison with optical particle image velocimetry (oPIV). Approach: Separate femoral bifurcation models were built for oPIV and ePIV measurements of a non-stenosed (control) and a 75%-area stenosed common femoral artery. A flow loop was used to create triphasic pulsatile flow. In-plane velocity vectors were measured with oPIV and ePIV. Flow was simulated with CFD using boundary conditions from ePIV and additional duplex-ultrasound (DUS) measurements. Mean differences and 95%-limits of agreement (1.96*SD) of the velocity magnitudes in space and time were compared, and the similarity of vector complexity (VC) and time-averaged wall shear stress (TAWSS) was assessed. Results: Similar flow features were observed between modalities with velocities up to 110 and 330 cm/s in the control and the stenosed model, respectively. Relative to oPIV, ePIV and CFD-ePIV showed negligible mean differences in velocity (<3 cm/s), with limits of agreement of ±25 cm/s (control) and ±34 cm/s (stenosed). CFD-DUS overestimated velocities with limits of agreements of 13±40 and 16.1±55 cm/s for the control and stenosed model, respectively. VC showed good agreement, whereas TAWSS showed similar trends but with higher values for ePIV, CFD-DUS, and CFD-ePIV compared to oPIV. Conclusions: EPIV and CFD-ePIV can accurately measure complex flow features in the femoral bifurcation and around a stenosis. CFD-DUS showed larger deviations in velocities making it a less robust technique for hemodynamical assessment. The applied ePIV and CFD techniques enable two- and three-dimensional assessment of local hemodynamics with high spatiotemporal resolution and thereby overcome key limitations of current clinical modalities making them an attractive and cost-effective alternative for hemodynamical assessment in clinical practice.

14.
Int J Pharm ; 658: 124209, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38718973

RESUMO

The USP Rotating Basket Dissolution Testing Apparatus 1 is listed in the USP as one of the tools to assess dissolution of oral solid dosage forms. Baskets of different mesh sizes can be used to differentiate between dissolution profiles of different formulations. Here, we used Particle Image Velocimetry (PIV) to study the hydrodynamics of the USP Apparatus 1 using baskets with different mesh openings (10-, 20- and 40-mesh) revolving at 100 rpm, when the vessel was filled with 500 mL. The velocity profiles throughout the liquid were found to vary significantly using baskets of different mesh sizes, typically increasing with increased size of the opening of the basket mesh, especially for axial and radial velocities. This, in turn, resulted in a significantly different flow rate through the basket, which can be expected to significantly impact the dissolution rate of the drug product. A comparison between the results of this work with those of a previous study with a 900-mL fill volume (Sirasitthichoke et al., Intern. J. Pharmaceutics, 2021, 607: 120976), shows that although the hydrodynamics in the USP Apparatus 1 changed with fill level in the vessel, the flow rate through the basket was not significantly affected. This implies that tablets dissolving in the two systems would experience similar tablet-liquid medium mass transfer coefficients, and therefore similar initial dissolution rates, but different dissolution profiles because of the difference in volume.


Assuntos
Liberação Controlada de Fármacos , Hidrodinâmica , Reologia , Solubilidade , Comprimidos , Reologia/métodos , Composição de Medicamentos/métodos , Composição de Medicamentos/instrumentação , Química Farmacêutica/métodos , Tamanho da Partícula , Tecnologia Farmacêutica/métodos
15.
Acta Biomater ; 181: 263-271, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38677636

RESUMO

The remarkable damage-tolerance of enamel has been attributed to its hierarchical microstructure and the organized bands of decussated rods. A thorough characterization of the microscale rod evolution within the enamel is needed to elucidate this complex structure. While prior efforts in this area have made use of single particle tracking to track a single rod evolution to various degrees of success, such a process can be both computationally and labor intensive, limited to the evolution path of a single rod, and is therefore prone to error from potentially tracking outliers. Particle image velocimetry (PIV) is a well-established algorithm to derive field information from image sequences for processes that are time-dependent, such as fluid flows and structural deformation. In this work, we demonstrate the use of PIV in extracting the full-field microstructural distribution of rods within the enamel. Enamel samples from a wild African lion were analyzed using high-energy synchrotron X-ray micro-tomography. Results from the PIV analysis provide sufficient full-field information to reconstruct the growth of individual rods that can potentially enable rapid analysis of complex microstructures from high resolution synchrotron datasets. Such information can serve as a template for designing damage-tolerant bioinspired structures for advanced manufacturing. STATEMENT OF SIGNIFICANCE: Thorough characterization and analysis of biological microstructures (viz. dental enamel) allows us to understand the basis of their excellent mechanical properties. Prior efforts have successfully replicated these microstructures via single particle tracking, but the process is computationally and labor intensive. In this work, optical flow imaging algorithms were used to extract full-field microstructural distribution of enamel rods from synchrotron X-ray computed tomography datasets, and a field method was used to reconstruct the growth of individual rods. Such high throughput information allows for the rapid production/prototyping and advanced manufacturing of damage-tolerant bioinspired structures for specific engineering applications. Furthermore, the algorithms used herein are freely available and open source to broaden the availability of the proposed workflow to the general scientific community.


Assuntos
Esmalte Dentário , Síncrotrons , Esmalte Dentário/química , Esmalte Dentário/diagnóstico por imagem , Animais , Microtomografia por Raio-X , Reologia , Imagem Óptica/métodos
16.
Lasers Med Sci ; 39(1): 112, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38656634

RESUMO

PURPOSE: To measure the dynamic characteristics of the flow field in a complex root canal model activated by two laser-activated irrigation (LAI) modalities at different activation energy outputs: photon-induced photoacoustic streaming (PIPS) and microshort pulse (MSP). METHODS: A phase-locked micro-scale Particle Image Velocimetry (µPIV) system was employed to characterise the temporal variations of LAI-induced velocity fields in the root canal following a single laser pulse. The wall shear stress (WSS) in the lateral root canal was subsequently estimated from the phase-averaged velocity fields. RESULTS: Both PIPS and MSP were able to generate the 'breath mode' of the irrigant current under all tested conditions. The transient irrigation flush in the root canal peaked at speeds close to 6 m/s. However, this intense flushing effect persisted for only about 2000 µs (or 3% of a single laser-pulse activation cycle). For MSP, the maximum WSS magnitude was approximately 3.08 Pa at an activation energy of E = 20 mJ/pulse, rising to 9.01 Pa at E = 50 mJ/pulse. In comparison, PIPS elevated the WSS to 10.63 Pa at E = 20 mJ/pulse. CONCLUSION: Elevating the activation energy can boost the peak flushing velocity and the maximum WSS, thereby enhancing irrigation efficiency. Given the same activation energy, PIPS outperforms MSP. Additionally, increasing the activation frequency may be an effective strategy to improve irrigation performance further.


Assuntos
Reologia , Humanos , Cavidade Pulpar/efeitos da radiação , Irrigação Terapêutica/métodos , Irrigação Terapêutica/instrumentação , Lasers , Irrigantes do Canal Radicular , Técnicas Fotoacústicas/métodos , Preparo de Canal Radicular/métodos , Preparo de Canal Radicular/instrumentação
17.
Med Eng Phys ; 126: 104144, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38621846

RESUMO

The present study adopts a smartphone-based approach for the experimental characterization of coronary flows. Technically, Particle Tracking Velocimetry (PTV) measurements were performed using a smartphone camera and a low-power continuous wave laser in realistic healthy and stenosed phantoms of left anterior descending artery with inflow Reynolds numbers approximately ranging from 20 to 200. A Lagrangian-Eulerian mapping was performed to convert Lagrangian PTV velocity data to a Eulerian grid. Eulerian velocity and vorticity data obtained from smartphone-based PTV measurements were compared with Particle Image Velocimetry (PIV) measurements performed with a smartphone-based setup and with a conventional setup based on a high-power double-pulsed laser and a CMOS camera. Smartphone-based PTV and PIV velocity flow fields substantially agreed with conventional PIV measurements, with the former characterized by lower average percentage differences than the latter. Discrepancies emerged at high flow regimes, especially at the stenosis throat, due to particle image blur generated by smartphone camera shutter speed and image acquisition frequency. In conclusion, the present findings demonstrate the feasibility of PTV measurements using a smartphone camera and a low-power light source for the in vitro characterization of cardiovascular flows for research, industrial and educational purposes, with advantages in terms of costs, safety and usability.


Assuntos
Fenômenos Fisiológicos Cardiovasculares , Smartphone , Reologia/métodos , Velocidade do Fluxo Sanguíneo , Imagens de Fantasmas
18.
J Biomech Eng ; 146(7)2024 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-38511303

RESUMO

Lowery urinary tract symptoms (LUTS) affect a large majority of the aging population. 3D Dynamic MRI shows promise as a noninvasive diagnostic tool that can assess bladder anatomy and function (urodynamics) while overcoming challenges associated with current urodynamic assessment methods. However, validation of this technique remains an unmet need. In this study, an anatomically realistic, bladder-mimicking in vitro flow model was created and used to systematically benchmark 3D dynamic MRI performance using a highly controllable syringe pump. Time-resolved volumes of the synthetic bladder model were obtained during simulated filling and voiding events and used to calculate volumetric flowrate. During MRI acquisitions, pressure during each event was recorded and used to create PV loops for work assessment. Error between control and MRI-derived volume for voiding and filling events exhibited 3.36% and 4.66% differences, respectively. A slight increase in average error was observed for MRI-derived flowrate when compared to the control flowrate (4.90% and 7.67% for voiding and filling, respectively). Overall, average error in segmented volumes increased with decreasing volume flowrate. Pressure drops were observed during voiding. Pressure increased during filling. Enhanced validation of novel 3D MRI urodynamics is achieved by using high-resolution PIV for visualizing and quantifying velocity inside the bladder model, which is not currently possible with 3D Dynamic MRI.


Assuntos
Bexiga Urinária , Urodinâmica , Bexiga Urinária/diagnóstico por imagem , Imageamento por Ressonância Magnética
19.
Sci Rep ; 14(1): 5368, 2024 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-38438434

RESUMO

Ultrasonic irrigation during root canal treatment can enhance biofilm disruption. The challenge is to improve the fluid flow so that the irrigant reaches areas inaccessible to hand instrumentation. The aim of this study is to experimentally investigate how the flow field and hydrodynamic forces induced by ultrasonic irrigation are influenced by the ultrasound power and file insertion depth. A root canal phantom was 3D printed and used as a mold for the fabrication of a PDMS channel. An ultrasonic instrument with a #15K-file provided the irrigation. The flow field was studied by means of Particle Image Velocimetry (PIV). The time averaged velocity and shear stress distributions were found to vary significantly with ultrasound power. Their maximum values increase sharply for low powers and up to a critical power level. At and above this setting, the flow pattern changes, from the high velocity and shear stress region confined in the vicinity of the tip, to one covering the whole root canal domain. Exceeding this threshold also induces a moderate increase in the maximum velocities and shear stresses. The insertion depth was found to have a smaller effect on the measured velocity and shear stresses. Due to the oscillating nature of the flow, instantaneous maximum velocities and shear stresses can reach much higher values than the mean, especially for high powers. Ultrasonic irrigation will benefit from using a higher power setting as this does produce greater shear stresses near the walls of the root canal leading to the potential for increased biofilm removal.


Assuntos
Cavidade Pulpar , Ultrassom , Ultrassonografia , Imagens de Fantasmas , Biofilmes
20.
Clin Med Insights Cardiol ; 18: 11795468231221413, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38449712

RESUMO

Supra-aortic extra-anatomic debranch (SAD) are prosthetic surgical grafts used to revascularize head and neck arteries that would be blocked during a surgical or hybrid procedure used in treating ascending and arch of the aorta pathologies. However, bypassing the supra-aortic arteries but not occluding their orifice might introduce potential for competitive flow that reduces bypass patency. Competitive flow within the bypasses across the supra-aortic arteries has not previously been identified. This research identified haemodynamics due to prophylactic inclusion of bypasses from the brachiocephalic artery (BCA) to the left common carotid artery (LCCA), and from the LCCA to left subclavian artery (LSA). Four model configurations investigated the risk of competitive flow and the necessity of intentionally blocking the proximal LSA and/or LCCA. Particle image velocimetry (PIV) was used to assess haemodynamics in each model configuration. We found potential for competitive flow in the BCA-LCCA bypass when the LSA was blocked, in the LSA-LCCA bypass, when the LCCA alone or LCCA and LSA were blocked. Flow stagnated at the start of systole within the RCCA-LCCA bypass, along with notable recirculation zones and reciprocating flow occurring throughout systolic flow. Flow also stagnated in the LCCA-LSA bypass when the LCCA was blocked. There was a large recirculation in the LCCA-LSA bypass when both the LCCA and LSA were blocked. The presence of competitive flow in all other configurations indicated that it is necessary to block or ligate the native LCCA and LSA once the debranch is made and the thoracic endovascular aortic repair (TEVAR) completed.