Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 13(24)2023 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-38132206

RESUMO

BACKGROUND: Handheld ultrasound (HHUS) devices have chiefly been deployed in emergency medicine, where they are considered a valid tool. The data situation is less clear in the case of internal questions in abdominal sonography. In our study, we investigate whether HHUS devices from different manufacturers differ in their B-scan quality, and whether any differences are relevant for the significance of an internal ultrasound examination. METHOD: The study incorporated eight HHUS devices from different manufacturers. Ultrasound videos of seven defined sonographic questions were recorded with all of the devices. The analogue recording of the same findings with a conventional high-end ultrasound (HEUS) device served as an evaluation criterion. Then, the corresponding findings were played side by side and evaluated by fourteen ultrasound experts using a point scale (5 points = very good; 1 point = insufficient). RESULTS: The HHUS devices achieved relatively good results in terms of both the B-scan quality assessment and the ability to answer the clinical question, regardless of the manufacturer. One of the tested HHUS devices even achieved a significantly (p < 0.05) higher average points score in both the evaluation of B-scan quality and in the evaluation of clinical significance than the other devices. Regardless of the manufacturer, the HHUS devices performed best when determining the status/inferior vena cava volume and in the representation of ascites/free fluid. CONCLUSION: In various clinical abdominal sonography questions, HHUS systems can reliably reproduce findings, and are-while bearing their limitations in mind-an acceptable alternative to conventional HEUS systems. Irrespective of this, the present study demonstrated relevant differences in the B-scan quality of HHUS devices from different manufacturers.

2.
Front Oncol ; 13: 1282536, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38125949

RESUMO

Elastography Ultrasound provides elasticity information of the tissues, which is crucial for understanding the density and texture, allowing for the diagnosis of different medical conditions such as fibrosis and cancer. In the current medical imaging scenario, elastograms for B-mode Ultrasound are restricted to well-equipped hospitals, making the modality unavailable for pocket ultrasound. To highlight the recent progress in elastogram synthesis, this article performs a critical review of generative adversarial network (GAN) methodology for elastogram generation from B-mode Ultrasound images. Along with a brief overview of cutting-edge medical image synthesis, the article highlights the contribution of the GAN framework in light of its impact and thoroughly analyzes the results to validate whether the existing challenges have been effectively addressed. Specifically, This article highlights that GANs can successfully generate accurate elastograms for deep-seated breast tumors (without having artifacts) and improve diagnostic effectiveness for pocket US. Furthermore, the results of the GAN framework are thoroughly analyzed by considering the quantitative metrics, visual evaluations, and cancer diagnostic accuracy. Finally, essential unaddressed challenges that lie at the intersection of elastography and GANs are presented, and a few future directions are shared for the elastogram synthesis research.

3.
Diagnostics (Basel) ; 14(1)2023 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-38201363

RESUMO

BACKGROUND: the use of handheld ultrasonography (HHUS) devices is well established in prehospital emergency diagnostics, as well as in intensive care settings. This is based on several studies in which HHUS devices were compared to conventional high-end ultrasonography (HEUS) devices. Nonetheless, there is limited evidence regarding potential variations in B-scan quality among HHUS devices from various manufacturers, and regarding whether any such differences hold clinical significance in intensive care medicine settings. METHODS: this study included the evaluation of eight HHUS devices sourced from diverse manufacturers. Ultrasound videos of five previously defined sonographic questions (volume status/inferior vena cava, pleural effusion, pulmonary B-lines, gallbladder, and needle tracking in situ) were recorded with all devices. The analogue recording of the same pathologies with a HEUS device served as gold standard. The corresponding findings (HHUS and HEUS) were then played side by side and evaluated by sixteen intensive care physicians experienced in sonography. The B-scan quality and the clinical significance of the HHUS were assessed using a five-point Likert scale (5 points = very good; 1 point = insufficient). RESULTS: both in assessing the quality of B-scans and in their ability to answer clinical questions, the HHUS achieved convincing results-regardless of the manufacturer. For example, only 8.6% (B-scan quality) and 9.8% (clinical question) of all submitted assessments received an "insufficient" rating. One HHUS device showed a significantly higher (p < 0.01) average points score in the assessment of B-scan quality (3.9 ± 0.65 points) and in the evaluation of clinical significance (4.03 ± 0.73 points), compared to the other devices. CONCLUSIONS: HHUS systems are able to reliably answer various clinical intensive care questions and are-while bearing their limitations in mind-an acceptable alternative to conventional HEUS devices. Irrespective of this, the present study was able to demonstrate relevant differences in the B-scan quality of HHUS devices from different manufacturers.

4.
Am J Obstet Gynecol ; 226(4): 552.e1-552.e6, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34774825

RESUMO

BACKGROUND: Personal-device-based point-of-care-ultrasound (P-POCUS) probes plug directly into a cell phone or tablet to function as its display, creating the potential to increase access to obstetric ultrasonography in complex healthcare settings (COVID units, low resource settings); however, new technology must be proven to be reliable in the obstetric setting before integrating into practice. OBJECTIVE: To evaluate the intraclass correlation (reliability) of personal-device-based-point-of-care-ultrasound devices as compared with standard ultrasound machines in obstetrics. STUDY DESIGN: This was a prospective, observational study of patients between 19-39 weeks gestation in an urban, prenatal ultrasound diagnosis center. Each patient underwent assessment by an expert sonographer using standard ultrasound machines and personal-device-based-point-of-care-ultrasound devices to determine estimated fetal weight. The statistical reliability and agreement between the estimated fetal weights was assessed through intraclass correlation coefficients, Bland-Altman plots, and Pearson correlation coefficients. RESULTS: 100 paired sets of scans were performed from October 2020 to December 2020. For the estimated fetal weights, there was near-perfect agreement, with an intraclass correlation coefficient of 0.99 (P<.0001). Bland-Altman analysis showed an average difference of 53 grams, with 95% limit of agreement between -178 grams and 283 grams. Pearson correlation showed near-perfect correlation between the measurements (r=0.99, P<.0001). CONCLUSION: personal-device-based point-of-care-ultrasound devices are reliable tools for performing basic obstetrical ultrasound and have the potential to increase access to obstetrical ultrasound worldwide.


Assuntos
COVID-19 , Sistemas Automatizados de Assistência Junto ao Leito , Feminino , Humanos , Gravidez , Estudos Prospectivos , Reprodutibilidade dos Testes , Ultrassonografia , Ultrassonografia Pré-Natal
5.
J Intensive Care Soc ; 22(3): 220-229, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34422105

RESUMO

Traditional ultrasound teaching is normally delivered using large, costly and often quite advanced cart-based systems. These carts are often large systems on wheels, usually limited to the departments that own them i.e. clinics, wards or radiology. Portability has been further improved by the development of laptop style systems, which are easier to wheel in-between patients/departments. In our experience and anecdotally, many of these systems can be intimidating to the novice and can lead to early attrition or poor uptake of ultrasound into clinical practice. Carts can also restrict the amount of training deliverable to practitioners, as they are limited in number due to cost and can take quite some time to boot up, reducing convenience. This dogma is being progressively changed with the advent of smaller handheld devices, some clearly within the financial grasps of most practitioners, and even to the point of medical schools offering students their own personal device.1,2 This relative inexpensiveness can lead to the purchase of these devices for novelty and convenience, over need. Obvious caution is needed in these circumstances, but with increased ease of purchase, better availability and inbuilt simplicity, ultrasound learning can be seamlessly integrated into day-to-day practice. This review discusses how one of the most disruptive innovations in modern medicine is changing ultrasound from a classic imaging modality to become integrated as the fifth pillar of clinical examination, and how these new devices can serve as springboards to more advanced ultrasound training. In fact, within what has become a bigger area of clinical examination, things are getting smaller.

6.
Curr Emerg Hosp Med Rep ; 9(3): 73-81, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33996272

RESUMO

PURPOSE OF REVIEW: Ultraportable handheld ultrasound (HHU) devices are being rapidly adopted by emergency medicine (EM) physicians. Though knowledge of the breadth of their utility and functionality is still limited compared to cart-based systems, these machines are becoming more common due to ease-of-use, extreme affordability, and improving technology. RECENT FINDINGS: Images obtained with HHU are comparable to those obtained with traditional machines but create unique issues regarding billing and data management. HHU devices are increasingly used successfully to augment the education of practitioners-in-training, by emergency physicians in austere environments, and in the burgeoning fields of "tele-ultrasound" and augmented reality scanning. SUMMARY: This review seeks to describe the current state of use of HHU devices in the emergency department (ED) including device overview, institutional concerns, unique areas of use, recent literature since their adoption into clinical EM, and their future potential.

7.
Dig Dis Sci ; 65(1): 82-85, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31376083

RESUMO

BACKGROUND AND AIMS: The high prevalence of nonalcoholic fatty liver disease (NAFLD) in the general population warrants determining whether pocket-sized ultrasound devices (PoCUS) might serve as point-of-care screening for NAFLD in busy office practices. METHODS: One hundred adult subjects undergoing conventional abdominal ultrasound (US) examinations for various indications were screened by PoCUS immediately prior to the conventional US procedure. The PoCUS examination only assessed the presence or absence of excess fat. Assessment of other liver pathology was not performed. Investigators (conventional US: an experienced radiologist and PoCUS: a general internist recently trained in the use of PoCUS) were blinded to the results of the alternative imaging. RESULTS: Forty patients (40%) had fatty infiltration of the liver on both conventional US and PoCUS, and 49 (49%) were negative by both modalities. A consensus was reached in two of the 11 remaining subjects with initially discrepant results. The overall sensitivity and specificity of PoCUS relative to conventional US were 91% and 88%, respectively. CONCLUSIONS: These findings support the use of PoCUS by a trained physician for point-of-care screening of patients at risk for NAFLD.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Fígado/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Sistemas Automatizados de Assistência Junto ao Leito , Testes Imediatos , Ultrassonografia/instrumentação , Adulto , Idoso , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miniaturização , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes
8.
Wilderness Environ Med ; 30(2): 186-190, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31056373

RESUMO

INTRODUCTION: Point-of-care ultrasonography is a burgeoning field of practice and study. Although point-of-care ultrasonography has started to penetrate the field of wilderness medicine, its use in cold environments is often limited by poor battery performance. In the current study, we investigated the effect of chemical foot warmers on battery runtime of handheld ultrasound machines in cold weather. METHODS: This prospective study used a balanced, crossover randomization design to compare handheld ultrasound machines exposed to cold weather with and without the application of chemical foot warmers. Time to power off, ambient temperature, air humidity, and wind speed were recorded for each trial and compared in a mixed-effects model analysis of variance. RESULTS: Ultrasound machines showed significantly decreased functional battery life with decreasing temperature (P<0.01) and increasing wind speed (P=0.01). Addition of the chemical foot warmer resulted in a statistically significant increase in handheld ultrasound machine runtime compared with controls (P<0.001). Overall machine runtime was increased by approximately 21.8 min (95% CI 16.2-27.3). CONCLUSIONS: The application of chemical foot warmers to handheld ultrasound machines exposed to cold environments prolongs usable battery life and, consequently, may allow for extended scanning time in austere and remote environments.


Assuntos
Temperatura Baixa , Ultrassonografia/instrumentação , Umidade , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos , Medicina Selvagem/instrumentação , Vento
9.
Int J Cardiol ; 280: 130-132, 2019 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-30665807

RESUMO

Acute dyspnea due to acute heart failure (AHF) is one of the most common reasons for admission to the Emergency Department (ED). The importance of lung ultrasound (LUS) examination in the diagnostic workup of AHF has been widely established. Limited anterior LUS examination for the diagnosis of AHF is controversial. This study compares the accuracy of LUS examination limited to the anterior or lateral lung zones for the diagnosis of AHF and their accuracy among patients with different levels of hypoxemia according to PO2/FiO2 ratio evaluation. We analyzed 170 patients admitted to the ED for acute dyspnea, who underwent multi-organ ultrasound examination of lung, heart and inferior vena cava for differential diagnosis. The thorax was examined following a simplified protocol that provides two scans at each side (anterior and lateral) to sample upper and lower lobes and the presence or the absence of interstitial syndrome (IS) was evaluated. The presence of anterior symmetric IS exhibited lower accuracy than lateral symmetric IS in the diagnosis of AHF in the whole population, but its diagnostic accuracy improves in sub-groups of patients with severe and critical hypoxemia.


Assuntos
Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Sistemas Automatizados de Assistência Junto ao Leito , Ultrassonografia de Intervenção/métodos , Doença Aguda , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Síndrome
10.
Eur Heart J Case Rep ; 3(4): 1-5, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32123785

RESUMO

BACKGROUND: Echocardiography has been traditionally performed in echo labs and the potential benefits of its use by primary care physicians (PCPs) are still unexplored. We present a case where POCUS (point-of-care ultrasound) was used as a complement of physical examination by a family doctor, allowing a prompt clinical decision in a heart failure (HF) patient. CASE SUMMARY: An 85-year-old woman, living independently, asks her family doctor for a home consultation due to increasing dyspnoea. On examination, severe dyspnoea and bilateral ankle oedema was noted and a point-of-care echocardiogram was performed by the primary care physician, who observed: severely compromised left ventricular systolic function, moderate mitral and tricuspid regurgitation, and severe dilation of the inferior vena cava. As a result, the diagnosis of HF with decreased ejection fraction was formed supporting the therapeutic decision. DISCUSSION: This case represents an elderly patient with dyspnoea, without previous HF diagnosis. The primary care physician, used portable ultrasound as a complement of physical examination, which confirmed a HF diagnosis, allowing a prompt decision-making on therapy. POCUS, can be a powerful tool to expedite treatment in different settings, including the home consultations by PCPs.

11.
Australas J Ultrasound Med ; 17(3): 110-112, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28191219

RESUMO

Introduction: Australian medical ultrasound started in 1959 with the establishment of the Ultrasonics Institute. Since then the technology has advanced tremendously. We are now not only able to obtain clearer images on high specification ultrasound machines but also on pocket-sized ultrasound machines that are compact, lightweight and affordable. Method: The following descriptive review will examine the indication for use of pocket ultrasound machines in different clinical settings as well as provide evidence of its image clarity and accuracy. Potentially eligible studies were sought primarily through searches of the electronic databases PubMed, Medline (1996-Present), Embase (1996-Present) and Cochrane Library. Conclusion: Pocket ultrasound machines, with appropriate ultrasound knowledge and training, can be incorporated successfully in patient management. The addition of point-of-care ultrasound has been shown to improve management recommendations and outcomes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA