Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Biosensors (Basel) ; 12(8)2022 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-36005020

RESUMO

The Zika virus (ZIKV) is a great concern for global health due to its high transmission, including disseminating through blood, saliva, urine, semen and vertical transmission. In some cases, ZIKV has been associated with microcephaly, neurological disorders, and Guillain−Barré syndrome. There is no vaccine, and controlling the disease is a challenge, especially with the co-circulation of the Dengue virus, which causes a severe cross-reaction due to the similarity between the two arboviruses. Considering that electrochemical immunosensors are well-established, sensitive, and practical tools for diagnosis, in this study we developed a sensor platform with intrinsic redox activity that facilitates measurement readouts. Prussian blue (PB) has a great ability to form electrocatalytic surfaces, dispensing redox probe solutions in voltammetric measurements. Herein, PB was incorporated into a chitosan−carbon nanotube hybrid, forming a nanocomposite that was drop-casted on a screen-printed electrode (SPE). The immunosensor detected the envelope protein of ZIKV in a linear range of 0.25 to 1.75 µg/mL (n = 8, p < 0.01), with a 0.20 µg/mL limit of detection. The developed immunosensor represents a new method for electrochemical measurements without additional redox probe solutions, and it is feasible for application in point-of-care diagnosis.


Assuntos
Técnicas Biossensoriais , Infecção por Zika virus , Zika virus , Técnicas Biossensoriais/métodos , Ferrocianetos , Humanos , Imunoensaio , Oxirredução , Infecção por Zika virus/diagnóstico
2.
AIDS Res Ther ; 17(1): 62, 2020 10 19.
Artigo em Inglês | MEDLINE | ID: mdl-33076996

RESUMO

BACKGROUND: Improved point-of-care diagnostic tests for tuberculosis (TB) in severe immune suppressed people living with HIV (PLWH) are needed to decrease morbidity and mortality outcomes. The aim of the study is to evaluate the performance of the lipoarabinomannan antigen test (LAM-test) with and without α-mannosidase pre-treated urine in a cohort of PLWH in primary care clinics in Guatemala. We further determined TB incidence, and mortality rates and its risk factors in PLWH with TB symptoms. METHODS: Prospective longitudinal study of PLWH with TB symptoms. Urine samples were collected at 2 HIV sites to test the sensitivity of the LAM-test in urine with and without α-mannosidase pre-treatment. A composite reference standard of either a positive Mycobacterium tuberculosis complex culture and/or GeneXpert® MTB/RIF (Xpert, Cepheid, Sunnyvale, CA, USA) results was used in the LAM-test diagnostic accuracy studies. Cox proportional hazards regression was used to study mortality predictors. RESULTS: The overall sensitivity of the LAM-test was of 56.1% with 95% CI of (43.3-68.3). There were no differences in the LAM-test sensitivity neither by hospital nor by CD4 T cell values. LAM-test sensitivity in PLWH with < 200 CD4 T cells/µl was of 62.2% (95% CI 46.5-76.2). There were no significant differences in sensitivity when comparing LAM-test results obtained from untreated vs. α-mannosidase treated urine [55.2% (95% CI 42.6-67.4) vs. 56.9% (95% CI 44-69.2), respectively]. TB incidence in our cohort was of 21.4/100 person years (PYs) (95% CI 16.6-27.6), and mortality rate was of 11.1/100 PYs (95% CI 8.2-15.0). Importantly, PLWH with a positive LAM-test result had an adjusted hazard ratio (aHR) of death of 1.98 (1.0-3.8) with a significant p value of 0.044 when compared to PLWH with a negative LAM-test result. CONCLUSIONS: In this study, α-mannosidase treatment of urine did not significantly increase the LAM-test performance, however; this needs to be further evaluated in a large-scale study due to our study limitations. Importantly, high rates of TB incidence and mortality were found, and a positive LAM-test result predicted mortality in PLWH with TB clinical symptoms.


Assuntos
Infecções por HIV , Tuberculose , Testes Diagnósticos de Rotina , Guatemala/epidemiologia , Infecções por HIV/diagnóstico , Infecções por HIV/tratamento farmacológico , Infecções por HIV/epidemiologia , Humanos , Lipopolissacarídeos , Estudos Longitudinais , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos , Sensibilidade e Especificidade , Tuberculose/diagnóstico , Tuberculose/epidemiologia
3.
ACS Sens ; 5(7): 1864-1871, 2020 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-32597643

RESUMO

Extracellular vesicles (EVs) are a frontier class of circulating biomarkers for the diagnosis and prognosis of different diseases. These lipid structures afford various biomarkers such as the concentrations of the EVs (CV) themselves and carried proteins (CP). However, simple, high-throughput, and accurate determination of these targets remains a key challenge. Herein, we address the simultaneous monitoring of CV and CP from a single impedance spectrum without using recognizing elements by combining a multidimensional sensor and machine learning models. This multidetermination is essential for diagnostic accuracy because of the heterogeneous composition of EVs and their molecular cargoes both within the tumor itself and among patients. Pencil HB cores acting as electric double-layer capacitors were integrated into a scalable microfluidic device, whereas supervised models provided accurate predictions, even from a small number of training samples. User-friendly measurements were performed with sample-to-answer data processing on a smartphone. This new platform further showed the highest throughput when compared with the techniques described in the literature to quantify EVs biomarkers. Our results shed light on a method with the ability to determine multiple EVs biomarkers in a simple and fast way, providing a promising platform to translate biofluid-based diagnostics into clinical workflows.


Assuntos
Vesículas Extracelulares , Dispositivos Lab-On-A-Chip , Aprendizado de Máquina , Neoplasias , Biomarcadores , Humanos
4.
Respir Med ; 128: 57-64, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28610670

RESUMO

BACKGROUND: Pneumonia is a leading cause of morbidity and mortality in children worldwide; however, its diagnosis can be challenging, especially in settings where skilled clinicians or standard imaging are unavailable. We sought to determine the diagnostic accuracy of lung ultrasound when compared to radiographically-confirmed clinical pediatric pneumonia. METHODS: Between January 2012 and September 2013, we consecutively enrolled children aged 2-59 months with primary respiratory complaints at the outpatient clinics, emergency department, and inpatient wards of the Instituto Nacional de Salud del Niño in Lima, Peru. All participants underwent clinical evaluation by a pediatrician and lung ultrasonography by one of three general practitioners. We also consecutively enrolled children without respiratory symptoms. Children with respiratory symptoms had a chest radiograph. We obtained ancillary laboratory testing in a subset. RESULTS: Final clinical diagnoses included 453 children with pneumonia, 133 with asthma, 103 with bronchiolitis, and 143 with upper respiratory infections. In total, CXR confirmed the diagnosis in 191 (42%) of 453 children with clinical pneumonia. A consolidation on lung ultrasound, which is our primary endpoint for pneumonia, had a sensitivity of 88.5%, specificity of 100%, and an area under-the-curve of 0.94 (95% CI 0.92-0.97) when compared to radiographically-confirmed clinical pneumonia. When any abnormality on lung ultrasound was compared to radiographically-confirmed clinical pneumonia the sensitivity increased to 92.2% and the specificity decreased to 95.2%, with an area under-the-curve of 0.94 (95% CI 0.91-0.96). CONCLUSIONS: Lung ultrasound had high diagnostic accuracy for the diagnosis of radiographically-confirmed pneumonia. Added benefits of lung ultrasound include rapid testing and high inter-rater agreement. Lung ultrasound may serve as an alternative tool for the diagnosis of pediatric pneumonia.


Assuntos
Pulmão/diagnóstico por imagem , Pneumonia/diagnóstico por imagem , Ultrassonografia/métodos , Asma/diagnóstico , Asma/epidemiologia , Bronquiolite/diagnóstico , Bronquiolite/epidemiologia , Pré-Escolar , Serviço Hospitalar de Emergência , Feminino , Recursos em Saúde/tendências , Humanos , Lactente , Pulmão/patologia , Masculino , Peru/epidemiologia , Pneumonia/epidemiologia , Pneumonia/mortalidade , Testes Imediatos , Radiografia/métodos , Infecções Respiratórias/diagnóstico , Infecções Respiratórias/epidemiologia
5.
Biosens Bioelectron ; 80: 24-33, 2016 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-26802749

RESUMO

Access to appropriate diagnostic tools is an essential component in the evaluation and improvement of global health. Additionally, timely detection of infectious agents is critical in early diagnosis and treatment of infectious diseases. Conventional pathogen detection methods such as culturing, enzyme linked immunosorbent assay (ELISA) or polymerase chain reaction (PCR) require long assay times, and complex and expensive instruments making them not adaptable to point-of-care (PoC) needs at resource-constrained places and primary care settings. Therefore, there is an unmet need to develop portable, simple, rapid, and accurate methods for PoC detection of infections. Here, we present the development and validation of a portable, robust and inexpensive electrochemical magnetic microbeads-based biosensor (EMBIA) platform for PoC serodiagnosis of infectious diseases caused by different types of microorganisms (parasitic protozoa, bacteria and viruses). We demonstrate the potential use of the EMBIA platform for in situ diagnosis of human (Chagas disease and human brucellosis) and animal (bovine brucellosis and foot-and-mouth disease) infections clearly differentiating infected from non-infected individuals or animals. For Chagas disease, a more extensive validation of the test was performed showing that the EMBIA platform displayed an excellent diagnostic performance almost indistinguishable, in terms of specificity and sensitivity, from a fluorescent immunomagnetic assay and the conventional ELISA using the same combination of antigens. This platform technology could potentially be applicable to diagnose other infectious and non-infectious diseases as well as detection and/or quantification of biomarkers at the POC and primary care settings.


Assuntos
Técnicas Biossensoriais , Doenças Transmissíveis/sangue , Ensaio de Imunoadsorção Enzimática/métodos , Testes Sorológicos/métodos , Animais , Bactérias/isolamento & purificação , Bactérias/patogenicidade , Doenças Transmissíveis/microbiologia , Doenças Transmissíveis/parasitologia , Doenças Transmissíveis/virologia , Humanos , Magnetismo , Parasitos/isolamento & purificação , Parasitos/patogenicidade , Sistemas Automatizados de Assistência Junto ao Leito , Vírus/isolamento & purificação , Vírus/patogenicidade
6.
Artigo em Espanhol | LILACS | ID: lil-660046

RESUMO

La periodontitis constituye la infección bacteriana más prevalente a nivel mundial y representa un factor de riesgo para diversas patologías sistémicas. El estado de inflamación y destrucción periodontal se manifiestan a través de la presencia de biomarcadores en el suero y fluidos orales, tales como el fluido gingival crevicular (FGC), saliva y enjuague oral. Enzimas como las metaloproteinasas de matriz (MMP) y mieloperoxidasa, constituyen biomarcadores potenciales para ensayos moleculares complementarios a la clínica de uso en el sillón dental. A continuación se presenta una revisión de la literatura respecto de la aplicación potencial del análisis de metaloproteinasas de matriz extracelular (MMPs) en el diagnóstico complementario de las enfermedades periodontales. Se ha demostrado que los niveles de MMP-9, -13 y particularmente de MMP-8, se asocian con el grado de inflamación periodontal, y pueden diferenciar entre sujetos sanos, con gingivitis, periodontitis y peri-implantitis, mientras que la mejoría de los parámetros clínicos en respuesta al tratamiento periodontal se asocia con la reducción de la activación y niveles de estas enzimas en FGC, como así también en el suero. Se concluye que la determinación, particularmente de MMP-8 en fluidos orales presenta un elevado potencial como complemento de los métodos clínicos tradicionales para identificar a los pacientes con periodontitis o en riesgo de desarrollar la enfermedad, monitorear fases del tratamiento y mejoría de signos periodontales e incluso evaluar el estado de inflamación sistémica.


Periodontal disease is the most common bacterial infection worldwide and it can contribute to enhance the risk for the development of several systemic diseases. The status of periodontal inflammation and destruction can be reflected in biomarker measurement in serum and oral fluids, like gingival crevicular fluid (GCF), saliva and mouth-rinse. Some enzymes, such as matrix metalloproteinases (MMPs) and myeloperoxidase are potential candidates for chair-side point-of-care oral fluid assays. This review is focused on the utility of matrix metalloproteinase (MMP) analysis in oral fluid as a complementary diagnostic method to chronic periodontitis. Levels of MMP-9,-13 and specially of MMP-8, reflect oral inflammatory status and discriminate among healthy, gingivitis, periodontitis and periimplantitis individuals, whereas MMP levels and activation in GCF and serum are in line with the improvement of clinical parameters in response to periodontal treatment. As a conclusion, MMP-8 assessment in GCF could represent a helpful adjunctive method to traditional diagnostics to identify periodontitis or patients at risk to develop the disease, monitor treatment phases, improvement of periodontal signs and even screen the systemic inflammation status.


Assuntos
Humanos , Colagenases/análise , Líquido do Sulco Gengival/enzimologia , Periodontite/diagnóstico , Periodontite/enzimologia , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/enzimologia , Biomarcadores/análise , /análise , Sistemas Automatizados de Assistência Junto ao Leito , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA