1.
Sensors (Basel) ; 24(10)2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38794056

RESUMO

Regional lung ventilation assessment is a critical tool for the early detection of lung diseases and postoperative evaluation. Biosensor-based impedance measurements, known for their non-invasive nature, among other benefits, have garnered significant attention compared to traditional detection methods that utilize pressure sensors. However, solely utilizing overall thoracic impedance fails to accurately capture changes in regional lung air volume. This study introduces an assessment method for lung ventilation that utilizes impedance data from the five lobes, develops a nonlinear model correlating regional impedance with lung air volume, and formulates an approach to identify regional ventilation obstructions based on impedance variations in affected areas. The electrode configuration for the five lung lobes was established through numerical simulations, revealing a power-function nonlinear relationship between regional impedance and air volume changes. An analysis of 389 pulmonary function tests refined the equations for calculating pulmonary function parameters, taking into account individual differences. Validation tests on 30 cases indicated maximum relative errors of 0.82% for FVC and 0.98% for FEV1, all within the 95% confidence intervals. The index for assessing regional ventilation impairment was corroborated by CT scans in 50 critical care cases, with 10 validation trials showing agreement with CT lesion localization results.


Assuntos
Impedância Elétrica , Pulmão , Ventilação Pulmonar , Testes de Função Respiratória , Humanos , Pulmão/diagnóstico por imagem , Pulmão/fisiologia , Pulmão/fisiopatologia , Testes de Função Respiratória/métodos , Ventilação Pulmonar/fisiologia , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Idoso , Tomografia Computadorizada por Raios X/métodos , Técnicas Biossensoriais/métodos , Eletrodos
2.
Front Physiol ; 15: 1352391, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38562620

RESUMO

For patients with chronic obstructive pulmonary disease (COPD), the assessment of the treatment efficacy during hospitalization is of importance to the optimization of clinical treatments. Conventional spirometry might not be sensitive enough to capture the regional lung function development. The study aimed to evaluate the feasibility of using electrical impedance tomography (EIT) as an objective bedside evaluation tool for the treatment of acute exacerbation of COPD (AECOPD). Consecutive patients who required hospitalization due to AECOPD were included prospectively. EIT measurements were conducted at the time of admission and before the discharge simultaneously when a forced vital capacity maneuver was conducted. EIT-based heterogeneity measures of regional lung function were calculated based on the impedance changes over time. Surveys for attending doctors and patients were designed to evaluate the ease of use, feasibility, and overall satisfaction level to understand the acceptability of EIT measurements. Patient-reported outcome assessments were conducted. User's acceptance of EIT technology was investigated with a five-dimension survey. A total of 32 patients were included, and 8 patients were excluded due to the FVC maneuver not meeting the ATS criteria. Spirometry-based lung function was improved during hospitalization but not significantly different (FEV1 %pred.: 35.8% ± 6.7% vs. 45.3% ± 8.8% at admission vs. discharge; p = 0.11. FVC %pred.: 67.8% ± 0.4% vs. 82.6% ± 5.0%; p = 0.15. FEV1/FVC: 0.41 ± 0.09 vs. 0.42 ± 0.07, p = 0.71). The symptoms of COPD were significantly improved, but the correlations between the improvement of symptoms and spirometry FEV1 and FEV1/FVC were low (R = 0.1 and -0.01, respectively). The differences in blood gasses and blood tests were insignificant. All but one EIT-based regional lung function parameter were significantly improved after hospitalization. The results highly correlated with the patient-reported outcome assessment (R > 0.6, p < 0.001). The overall acceptability score of EIT measurement for both attending physicians and patients was high (4.1 ± 0.8 for physicians, 4.5 ± 0.5 for patients out of 5). These results demonstrated that it was feasible and acceptable to use EIT as an objective bedside evaluation tool for COPD treatment efficacy.

3.
Physiol Meas ; 45(4)2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38479002

RESUMO

Objective. This study aims to explore the possibility of using electrical impedance tomography (EIT) to assess pursed lips breathing (PLB) performance of patients with chronic obstructive pulmonary disease (COPD).Methods. 32 patients with COPD were assigned equally to either the conventional group or the EIT guided group. All patients were taught to perform PLB by a physiotherapist without EIT in the conventional group or with EIT in the EIT guided group for 10 min. The ventilation of all patients in the final test were continuously monitored using EIT and the PLB performances were rated by another physiotherapist before and after reviewing EIT. The global and regional ventilation between two groups as well as between quite breathing (QB) and PLB were compared and rating scores with and without EIT were also compared.Results.For global ventilation, the inspiratory depth and the ratio of expiratory-to-inspiratory time during PLB was significantly larger than those during QB for both group (P< 0.001). The inspiratory depth and the ratio of expiratory-to-inspiratory time during PLB in the EIT guided group were higher compared to those in the conventional group (P< 0.001), as well as expiratory flow expiratory uniformity and respiratory stability were better (P< 0.001). For regional ventilation, center of ventilation significantly decreased during PLB (P< 0.05). The expiratory time constant during PLB in the EIT guided group was greater than that in the conventional group (P< 0.001). Additionally, Bland-Altman plots analysis suggested a high concordance between subjective rating and rating with the help of EIT, but the score rated after EIT observation significantly lower than that rated subjectively in both groups (score drop of -2.68 ± 1.1 in the conventional group and -1.19 ± 0.72 in the EIT guided group,P< 0.01).Conclusion.EIT could capture the details of PLB maneuver, which might be a potential tool to quantitatively evaluate PLB performance and thus assist physiotherapists to teach PLB maneuver to patients.


Assuntos
Lábio , Doença Pulmonar Obstrutiva Crônica , Humanos , Impedância Elétrica , Respiração , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Tomografia
4.
Biomedicines ; 11(11)2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-38002067

RESUMO

High-flow nasal cannula (HFNC) is widely used to treat hypoxemic respiratory failure. The effectiveness of HFNC treatment and the methods for monitoring its efficacy in the general ward remain unclear. This prospective observational study enrolled 42 patients who had acute hypoxemic respiratory failure requiring HFNC oxygen therapy in the general adult respiratory ward. The primary outcome was the all-cause in-hospital mortality. Secondary outcomes included the association between initial blood test results and HFNC outcomes. Regional ventilation distributions were monitored in 24 patients using electrical impedance tomography (EIT) after HFNC initiation. Patients with successful HFNC treatment had better in-hospital survival (94%) compared to those with failed HFNC treatment (0%, p < 0.001). Neutrophil-to-lymphocyte ratios of ≥9 were more common in patients with failed HFNC (70%) compared to those with successful HFNC (52%, p = 0.070), and these patients had shorter hospital survival rates after HFNC treatment (p = 0.046, Tarone-Ware test). Patients with successful HFNC treatment had a more central ventilation distribution compared to those with failed HFNC treatment (p < 0.05). Similarly, patients who survived HFNC treatment had a more central distribution compared to those who did not survive (p < 0.001). We concluded that HFNC in the general respiratory ward may be a potential rescue therapy for patients with respiratory failure. EIT can potentially monitor patients receiving HFNC therapy.

5.
COPD ; 20(1): 248-255, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37477218

RESUMO

We hypothesized that the respiratory exercises have uniform effects on ventilation in healthy subjects but the effects varied in patients with chronic obstructive pulmonary disease (COPD). In this study, a total of 30 healthy volunteers and 9 patients with COPD were included. Data were recorded continuously during (1) diaphragmatic breathing; (2) pursed lip breathing with full inhalation; (3) pursed lip combining diaphragmatic breathing. The sequence of the three breathing exercises was randomized using machine generated random permutation. Spatial and temporal ventilation distributions were evaluated with electrical impedance tomography. Results showed that, tidal volume was significantly larger during various breathing exercises compared to quiet tidal breathing, in both healthy and COPD (p < 0.01). However, for other EIT-based parameters, statistical significances were only observed in healthy volunteers, not in patients. Diaphragmatic breathing alone might not be able to decrease functional residual capacity in COPD and the effect varied largely from patient to patient (6:3, decrease vs. increase). Ventilation distribution moved toward ventral regions in healthy during breathing exercises (p < 0.0001). Although this trend was observed in the COPD, the differences were not significant. Ventilation became more homogeneous when diaphragmatic breathing technique was implemented (p < 0.0001). Again, the improvements were not significant in COPD. Regional ventilation delay was relatively high in COPD and comparable in various breathing periods. In conclusions, the impact of pursed lip and diaphragmatic breathing varied in different patients with COPD. Breathing exercise may need to be individualized to maximize the training efficacy with help of EIT.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Humanos , Doença Pulmonar Obstrutiva Crônica/terapia , Pulmão , Respiração , Exercícios Respiratórios , Testes de Função Respiratória/métodos
6.
Physiother Theory Pract ; 39(5): 938-953, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35105251

RESUMO

BACKGROUND: Scoliosis curves present transverse plane deviations due to vertebral rotation. The Schroth method supports thoracic derotation by training patients to exert "derotational" breathing based on assumed enhanced ventilation in areas called "humps" in scoliosis and a patient's ability to voluntarily direct ventilation in less ventilated areas called "flats." OBJECTIVE: To assess the asymmetric ventilation distribution and the ability of patients to direct their ventilation to perform derotational breathing. METHODS: Twelve girls with adolescent idiopathic scoliosis and 12 healthy girls performed 3 × 3 min of rest, maximal, and derotational breathing. Electrical impedance tomography was used to record locoregional lung ventilation distribution (LLVD) within 4 thoracic regions of interest: anterior right (ROI 1), anterior left (ROI 2), posterior right (ROI 3), and posterior left (ROI 4) quadrants. Humps and flats were the sums of ROI '2 + 3' and ROI '1 + 4,' respectively. RESULTS: Overall, no difference in LLVD was observed in the flats and humps between groups. At rest, the LLVD in the humps was more elevated than that in the flats (51.5 ± 8.1% versus 43.6 ± 7.9%; p = .021) when considering both groups. Maximal and derotational breathing led to a more homogeneous LLVD between the humps and flats. CONCLUSION: The postulated derotational breathing effect was not confirmed.


Assuntos
Cifose , Escoliose , Adolescente , Feminino , Humanos , Pulmão , Escoliose/terapia , Coluna Vertebral , Tomografia Computadorizada por Raios X
7.
Acta Anaesthesiol Scand ; 67(2): 185-194, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36268561

RESUMO

BACKGROUND: Gravity-dependent positioning therapy is an established concept in the treatment of severe acute respiratory distress syndrome and improves oxygenation in spontaneously breathing patients with hypoxemic acute respiratory failure. In patients with coronavirus disease 2019, this therapy seems to be less effective. Electrical impedance tomography as a point-of-care functional imaging modality for visualizing regional ventilation can possibly help identify patients who might benefit from positioning therapy and guide those maneuvers in real-time. Therefore, in this prospective observational study, we aimed to discover typical patterns in response to positioning maneuvers. METHODS: Distribution of ventilation in 10 healthy volunteers and in 12 patients with hypoxemic respiratory failure due to coronavirus disease 2019 was measured in supine, left, and right lateral positions using electrical impedance tomography. RESULTS: In this study, patients with coronavirus disease 2019 showed a variety of ventilation patterns, which were not predictable, whereas all but one healthy volunteer showed a typical and expected gravity-dependent distribution of ventilation with the body positions. CONCLUSION: Distribution of ventilation and response to lateral positioning is variable and thus unpredictable in spontaneously breathing patients with coronavirus disease 2019. Electrical impedance tomography might add useful information on the immediate reaction to postural maneuvers and should be elucidated further in clinical studies. Therefore, we suggest a customized individualized positioning therapy guided by electrical impedance tomography.


Assuntos
COVID-19 , Insuficiência Respiratória , Humanos , Impedância Elétrica , Tomografia/métodos , COVID-19/terapia , Respiração , Tomografia Computadorizada por Raios X
8.
Heliyon ; 8(12): e12454, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36590551

RESUMO

Background: Some electrical impedance tomography (EIT) devices equip reference electrodes. In practice, it is not uncommon to observe high contact impedance for the reference electrode. The influence of bad contact reference electrode on data quality is unknown. The study aimed to investigate the influence of reference electrode on EIT image reconstruction. Methods: Thirty lung healthy volunteers were prospectively examined with EIT. The subjects were spontaneously breathing in supine position. Three scenarios were constructed: 1. Normal measurement; 2. Reference electrode disconnected without recalibration; 3. Reference electrode disconnected, and the measurement restarted after recalibration of the system. EIT-based parameters measuring spatial and temporal ventilation distributions were calculated and compared. A so-call deviation score was calculated to assess the differences in EIT parameters between scenarios 2 and 1, between 3 and 1. Results: The absolute differences for all parameters were significantly higher than zero (p < 0.01 for all parameters and scenarios). Deviation score for scenario 2 was 4.5 ± 3.5. Four subjects had a deviation score of 0 in scenario 2 and five subjects had a score of 1. The deviation in scenario 3 was higher (6.1 ± 3.1). No subjects had a score of 0 and only two subjects had a score of 1. Conclusions: For EIT systems that equips with reference electrode, it is important to ensure the proper contact and functionality of the reference electrode. The EIT data quality would remain unchanged in only a small portion of subjects.

9.
Front Physiol ; 12: 748724, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34721072

RESUMO

As a portable, radiation-free imaging modality, electrical impedance tomography (EIT) technology has shown promise in the bedside visual assessment of lung perfusion distribution in critically ill patients. The two main methods of EIT for assessing lung perfusion are the pulsatility and conductivity contrast (saline) bolus method. Increasing attention is being paid to the saline bolus EIT method in the evaluation of regional pulmonary perfusion in clinical practice. This study seeks to provide an overview of experimental and clinical studies with the aim of clarifying the progress made in the use of the saline bolus EIT method. Animal studies revealed that the saline bolus EIT method presented good consistency with single-photon emission CT (SPECT) in the evaluation of lung regional perfusion changes in various pathological conditions. Moreover, the saline bolus EIT method has been applied to assess the lung perfusion in a pulmonary embolism and the effect of positive end-expiratory pressure (PEEP) on regional ventilation/perfusion ratio (V/Q) and acute respiratory distress syndrome (ARDS) in several clinical studies. The implementation of saline boluses, data analyses, precision, and cutoff values varied among different studies, and a consensus must be reached regarding the clinical application of the saline bolus EIT method. Further study is required to validate the impact of the described saline bolus EIT method on decision-making, therapeutic management, and outcomes in critically ill patients.

10.
Comput Biol Med ; 135: 104592, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34214941

RESUMO

OBJECTIVE: Anti-gravity straining maneuver (AGSM) helps to reduce the occurrence of gravity-induced visual disturbances and loss of consciousness. An objective assessment of the AGSM is still missing during ground training. This study evaluated the feasibility of using electrical impedance tomography (EIT) to assess the performance of AGSM. METHODS: Eight undergraduates and eight teachers majoring in aerospace medicine were included in the study. An experienced professor from the department of aerospace medicine reviewed the key points of AGSM with each subject. EIT measurement was performed during AGSM. The global and regional ventilation were used to investigate the characteristics of AGSM. The professor and the subjects rated the performance of AGSM according to the maneuver requirements of AGSM (maximum 16 points) before and after reviewing the ventilations from EIT. RESULTS: For global ventilation, the relative depth of gas exchange and duration of exhalation of the teachers were larger than those of the students (p < 0.01), and stability of the teachers was better as well (p < 0.001). No difference in the duration of gas exchange and leakage during exhalation between the teachers and the students was found. For regional ventilation, the teachers had significantly increased ventral ventilation during AGSM implementation (p < 0.001) whereas students did otherwise. Additionally, the differences of rating scores with and without EIT were also significant. Significant reductions were found in rating scores with EIT assessed by the professor (4.5 ± 2.0, p < 0.001) and by the students themselves (3.9 ± 2.2, p < 0.001). The scores were systematically higher when the students rated themselves compared with the professor's rating (p < 0.001 for both with and without EIT). CONCLUSION: These findings demonstrated that EIT could objectively characterize the maneuver details of AGSM, which might provide a potential tool for real-time assessment of AGSM quality in an objective manner.


Assuntos
Medicina Aeroespacial , Impedância Elétrica , Humanos , Pulmão , Respiração Artificial , Tomografia , Tomografia Computadorizada por Raios X
11.
Ann Transl Med ; 9(9): 789, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34268402

RESUMO

BACKGROUND: Although electrical impedance tomography (EIT) is widely used for monitoring regional ventilation distribution, reference values have yet to be established for clinical use. The present study aimed to evaluate the feasibility of creating reference values for standard EIT parameters for potential clinical application. METHODS: A total of 75 participants with healthy lungs were included in this prospective study (male:female, 48:27; age, 34±14 years; height, 172±7 cm; weight, 73±12 kg). The subjects were examined during spontaneous breathing in the supine position. EIT measurements were performed at the level of the 4th intercostal space. Commonly used EIT-based parameters, including the center of ventilation (CoV), dorsal and most dorsal fractions of ventilation distribution (TVD and TVROI4 respectively), global inhomogeneity (GI) index, and standard deviation of regional ventilation delay index (RVDSD) were calculated. RESULTS: Following outlier detection, EIT data from 71 subjects were finally evaluated. The values of the evaluated parameters were: CoV, 48.7%±1.7%; TVD, 48.1%±5.4%; TVROI4, 7.1%±1.8%; GI, 0.49±0.04; and RVDSD, 7.0±2.0. The coefficients of variation for CoV and GI were low (0.03 and 0.07, respectively), but those for TVROI4 and RVDSD were comparatively high (0.26 and 0.28, respectively). None of the evaluated parameters showed a significant correlation with age. The GI index showed a weak but significant correlation with body mass index (R=0.29, P=0.01). The RVDSD was slightly higher in males than in females. CONCLUSIONS: Our study indicated that CoV and GI were stable parameters with small coefficients of variation in participants with healthy lungs. The creation of EIT parameter reference values for setting treatment targets may be feasible.

12.
J Cardiothorac Vasc Anesth ; 35(11): 3416-3422, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34103214

RESUMO

The current methods of mechanical ventilation and pulmonary drug delivery do not account for the heterogeneity of acute respiratory distress syndrome or its dependence on gravity. The severe lung disease caused by severe acute respiratory distress syndrome coronavirus 2, coronavirus disease 2019, is one of the many causes of acute respiratory distress syndrome. Severe acute respiratory distress syndrome coronavirus 2 has caused more than three million deaths worldwide and has challenged all therapeutic options for mechanical ventilation. Thus, new therapies are necessary to prevent deaths and long-term complications of severe lung diseases and prolonged mechanical ventilation. The authors of the present report have developed a novel device that allows selective lobe ventilation and selective lobe recruitment and provides a new platform for pulmonary drug delivery. A major advantage of separating lobes that are mechanically heterogeneous is to allow for customization of ventilator parameters to match the needs of segments with similar compliance, a better overall ventilation perfusion relationship, and prevention of ventilator-induced lung injury of more compliant lobes. This device accounts for lung heterogeneity and is a potential new therapy for acute lung injury by allowing selective lobe mechanical ventilation using two novel modes of mechanical ventilation (differential positive end-expiratory pressure and asynchronous ventilation), and two new modalities of alveolar recruitment (selective lobe recruitment and continuous positive airway pressure of lower lobes with continuous ventilation of upper lobes). Herein the authors report their initial experience with this novel device, including a brief overview of device development; the initial in vitro, ex vivo, and in vivo testing; layout of future research; potential benefits and new therapies; and expected challenges before its uniform implementation into clinical practice.


Assuntos
COVID-19 , Preparações Farmacêuticas , Pressão Positiva Contínua nas Vias Aéreas , Humanos , Pulmão , SARS-CoV-2
13.
Respir Care ; 66(5): 751-757, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33653911

RESUMO

BACKGROUND: Bronchopulmonary dysplasia (BPD) is a heterogeneous disease that poses a challenge when ventilating premature infants. The purpose of this study was to determine how inspiratory pressure rise time (IRT), different ventilators, and their software updates affect the balance of ventilation among 2 heterogeneous lung units. METHODS: A passive dual-chamber lung model was constructed using the IngMar ASL5000 to approximate moderate BPD. One chamber had a short time constant, and the other had a long time constant. Three ventilators were used to provide pressure control intermittent mandatory ventilation: the Servo-i, an Avea ventilator with the volume guarantee software update, and an Avea ventilator without the volume guarantee software update. Using the same settings for pressure control intermittent mandatory ventilation, the IRT was adjusted between minimum and maximum settings. Data from 100 consecutive breaths/IRT were obtained. Inspiration time to 90% of plateau pressure was used as a surrogate for IRT; this was defined as the time needed to achieve a pressure of 18 cm H2O at the simulated trachea and was measured in 5 random breaths using ImageJ for each ventilator at each IRT. Outcome variables were tidal volume, peak inspiratory flow, mean inspiratory pressure, and volume balance (%) defined as the difference in chamber tidal volumes divided by total tidal volume. Linear regression was used to assess the impact of the IRT and ventilators on the different variables. RESULTS: In this model, increasing IRT decreased peak inspiratory flow, mean inspiratory pressure, chamber-specific tidal volume, and volume balance. Furthermore, different ventilator hardware and software influenced the waveforms in pressure control intermittent mandatory ventilation, which independently affected the measured variables. CONCLUSIONS: In a lung model of BPD with 2 very heterogeneous lung units, prolonging IRT without any volume balancing measures improved volume balance between the chambers at the expense of total tidal volume. Furthermore, the different ventilators acted as independent factors from the measured inspiration time to 90% of plateau pressure.


Assuntos
Displasia Broncopulmonar , Displasia Broncopulmonar/terapia , Humanos , Lactente , Recém-Nascido , Pulmão , Respiração Artificial , Software , Volume de Ventilação Pulmonar , Ventiladores Mecânicos
14.
J Pediatr ; 228: 24-30.e10, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32827530

RESUMO

OBJECTIVE: To describe the regional distribution patterns of tidal ventilation within the lung during mechanical ventilation that is synchronous or asynchronous with an infant's own breathing effort. STUDY DESIGN: Intubated infants receiving synchronized mechanical ventilation at The Royal Children's Hospital neonatal intensive care unit were studied. During four 10-minute periods of routine care, regional distribution of tidal volume (VT; electrical impedance tomography), delivered pressure, and airway flow (Florian Respiratory Monitor) were measured for every inflation. Post hoc, each inflation was then classified as synchronous or asynchronous from video data of the ventilator screen, and the distribution of absolute VT and delivered ventilation characteristics determined. RESULTS: In total, 2749 inflations (2462 synchronous) were analyzed in 19 infants; mean (SD) age 28 (30) days, gestational age 35 (5) weeks. Synchronous inflations were associated with a shorter respiratory cycle (P = .004) and more homogenous VT (center of ventilation) along the right (0%) to left (100%) lung plane; 45.3 (8.6)% vs 48.8 (9.4)% (uniform ventilation 46%). The gravity-dependent center of ventilation was a mean (95% CI) 2.1 (-0.5, 4.6)% toward the dependent lung during synchronous inflations. Tidal ventilation relative to anatomical lung size was more homogenous during synchronized inflations in the dependent lung. CONCLUSIONS: Synchronous mechanical ventilator lung inflations generate more gravity-dependent lung ventilation and more uniform right-to-left ventilation than asynchronous inflations.


Assuntos
Unidades de Terapia Intensiva Neonatal , Intubação Intratraqueal/métodos , Pulmão/fisiopatologia , Respiração Artificial/métodos , Insuficiência Respiratória/terapia , Feminino , Seguimentos , Idade Gestacional , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Masculino , Insuficiência Respiratória/fisiopatologia , Estudos Retrospectivos , Volume de Ventilação Pulmonar
15.
Respir Res ; 21(1): 288, 2020 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-33129315

RESUMO

BACKGROUND: Benefits of variable mechanical ventilation based on the physiological breathing pattern have been observed both in healthy and injured lungs. These benefits have not been characterized in pediatric models and the effect of this ventilation mode on regional distribution of lung inflammation also remains controversial. Here, we compare structural, molecular and functional outcomes reflecting regional inflammation between PVV and conventional pressure-controlled ventilation (PCV) in a pediatric model of healthy lungs and acute respiratory distress syndrome (ARDS). METHODS: New-Zealand White rabbit pups (n = 36, 670 ± 20 g [half-width 95% confidence interval]), with healthy lungs or after induction of ARDS, were randomized to five hours of mechanical ventilation with PCV or PVV. Regional lung aeration, inflammation and perfusion were assessed using x-ray computed tomography, positron-emission tomography and single-photon emission computed tomography, respectively. Ventilation parameters, blood gases and respiratory tissue elastance were recorded hourly. RESULTS: Mechanical ventilation worsened respiratory elastance in healthy and ARDS animals ventilated with PCV (11 ± 8%, 6 ± 3%, p < 0.04), however, this trend was improved by PVV (1 ± 4%, - 6 ± 2%). Animals receiving PVV presented reduced inflammation as assessed by lung normalized [18F]fluorodeoxyglucose uptake in healthy (1.49 ± 0.62 standardized uptake value, SUV) and ARDS animals (1.86 ± 0.47 SUV) compared to PCV (2.33 ± 0.775 and 2.28 ± 0.3 SUV, respectively, p < 0.05), particularly in the well and poorly aerated lung zones. No benefit of PVV could be detected on regional blood perfusion or blood gas parameters. CONCLUSIONS: Variable ventilation based on a physiological respiratory pattern, compared to conventional pressure-controlled ventilation, reduced global and regional inflammation in both healthy and injured lungs of juvenile rabbits.


Assuntos
Pneumonia/fisiopatologia , Pneumonia/terapia , Respiração Artificial/métodos , Síndrome do Desconforto Respiratório/fisiopatologia , Síndrome do Desconforto Respiratório/terapia , Mecânica Respiratória/fisiologia , Animais , Animais Recém-Nascidos , Modelos Animais de Doenças , Feminino , Pulmão/fisiopatologia , Masculino , Pneumonia/diagnóstico por imagem , Coelhos , Respiração Artificial/tendências , Síndrome do Desconforto Respiratório/diagnóstico por imagem
16.
J Clin Med ; 8(8)2019 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-31394721

RESUMO

Electrical impedance tomography (EIT) is a bedside monitoring tool that noninvasively visualizes local ventilation and arguably lung perfusion distribution. This article reviews and discusses both methodological and clinical aspects of thoracic EIT. Initially, investigators addressed the validation of EIT to measure regional ventilation. Current studies focus mainly on its clinical applications to quantify lung collapse, tidal recruitment, and lung overdistension to titrate positive end-expiratory pressure (PEEP) and tidal volume. In addition, EIT may help to detect pneumothorax. Recent studies evaluated EIT as a tool to measure regional lung perfusion. Indicator-free EIT measurements might be sufficient to continuously measure cardiac stroke volume. The use of a contrast agent such as saline might be required to assess regional lung perfusion. As a result, EIT-based monitoring of regional ventilation and lung perfusion may visualize local ventilation and perfusion matching, which can be helpful in the treatment of patients with acute respiratory distress syndrome (ARDS).

17.
Intensive Care Med Exp ; 7(1): 11, 2019 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-30771111

RESUMO

BACKGROUND: The provision of guidance in ventilator therapy by continuous monitoring of regional lung ventilation, aeration and respiratory system mechanics is the main clinical benefit of electrical impedance tomography (EIT). A new application was recently described in critically ill patients undergoing diagnostic bronchoalveolar lavage (BAL) with the intention of using EIT to identify the region where sampling was performed. Increased electrical bioimpedance was reported after fluid instillation. To verify the accuracy of these findings, contradicting the current EIT knowledge, we have systematically analysed chest EIT data acquired under controlled experimental conditions in animals undergoing a large number of BAL procedures. METHODS: One hundred thirteen BAL procedures were performed in 13 newborn piglets positioned both supine and prone. EIT data was obtained at 13 images before, during and after each BAL. The data was analysed at three time points: (1) after disconnection from the ventilator before the fluid instillation and by the ends of fluid (2) instillation and (3) recovery by suction and compared with the baseline measurements before the procedure. Functional EIT images were generated, and changes in pixel electrical bioimpedance were calculated relative to baseline. The data was examined in the whole image and in three (ventral, middle, dorsal) regions-of-interest per lung. RESULTS: Compared with the baseline phase, chest electrical bioimpedance fell after the disconnection from the ventilator in all animals in both postures during all procedures. The fluid instillation further decreased electrical bioimpedance. During fluid recovery, electrical bioimpedance increased, but not to baseline values. All effects were highly significant (p < 0.001). The fractional changes in individual regions-of-interest were posture-dependent. The regional fall in electrical bioimpedance was smaller in the ventral and larger in the dorsal regions after the fluid instillation than after the initial disconnection to ambient pressure in supine animals (p < 0.001) whereas these changes were of comparable amplitude in prone position. CONCLUSIONS: The results of this study show a regionally dissimilar initial fall in electrical bioimpedance caused by non-uniform aeration loss at the beginning of the BAL procedure. They also confirm a further pronounced fall in bioimpedance during fluid instillation, incomplete recovery after suction and a posture-dependent distribution pattern of these effects.

18.
Am J Respir Crit Care Med ; 199(9): 1086-1096, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-30641027

RESUMO

Rationale: In the CLAIM study, dual bronchodilation with indacaterol/glycopyrronium (IND/GLY) significantly reduced hyperinflation, which translated into improved cardiac function, measured by left ventricular end-diastolic volume and cardiac output. Pulmonary microvascular blood flow (PMBF) is reduced in chronic obstructive pulmonary disease (COPD); however, the effect of reduced lung hyperinflation on PMBF remains unknown. Objectives: To determine the effect of lung deflation with IND/GLY on PMBF and regional pulmonary ventilation using magnetic resonance imaging (MRI) in hyperinflated patients with COPD. Methods: In this double-blind, randomized, two-period crossover study, gadolinium-enhanced MRI and phase-resolved functional lung MRI were used to measure PMBF and regional ventilation, respectively, in patients with COPD receiving IND/GLY versus placebo. Measurements and Main Results: Sixty-two patients were randomized to receive once-daily IND/GLY (110/50 µg) for 14 days, followed by 14 days of placebo, or vice versa. Treatment periods were separated by a 14-day washout. Sixty patients were included in the per-protocol analysis. MRI measurements showed significant improvements in total PMBF (P = 0.006) and regional PMBF (P values for individual lobes were between 0.004 and 0.022) in response to IND/GLY versus placebo. Regional ventilation was also significantly improved with IND/GLY, as evidenced by a 12.4% increase versus placebo (P = 0.011), a 14.3% relative decrease in ventilation defect percentage of nonventilated/hypoventilated lung tissue (cutoff was defined as 0.075 regional ventilation; P = 0.0002), and a 15.7% reduction in the coefficient of variation of regional ventilation compared with placebo (P < 0.0001). Conclusions: Pharmacologic intervention with IND/GLY improves pulmonary microvascular blood flow and regional ventilation in patients with COPD with hyperinflation. Clinical trial registered with www.clinicaltrials.gov (NCT02442206).


Assuntos
Antiasmáticos/uso terapêutico , Glicopirrolato/uso terapêutico , Indanos/uso terapêutico , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Quinolonas/uso terapêutico , Idoso , Débito Cardíaco/efeitos dos fármacos , Estudos Cross-Over , Método Duplo-Cego , Combinação de Medicamentos , Feminino , Humanos , Pulmão/irrigação sanguínea , Pulmão/diagnóstico por imagem , Pulmão/efeitos dos fármacos , Pulmão/fisiopatologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Circulação Pulmonar/efeitos dos fármacos , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Função Ventricular Esquerda/efeitos dos fármacos
19.
J Intensive Care ; 7: 4, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30680219

RESUMO

Mechanical ventilation can initiate ventilator-associated lung injury (VALI) and contribute to the development of multiple organ dysfunction. Although a lung protective strategy limiting both tidal volume and plateau pressure reduces VALI, uneven intrapulmonary gas distribution is still capable of increasing regional stress and strain, especially in non-homogeneous lungs, such as during acute respiratory distress syndrome. Real-time monitoring of regional ventilation may prevent inhomogeneous ventilation, leading to a reduction in VALI. Electrical impedance tomography (EIT) is a technique performed at the patient's bedside. It is noninvasive and radiation-free and provides dynamic tidal images of gas distribution. Studies have reported that EIT provides useful information both in animal and clinical studies during mechanical ventilation. EIT has been shown to be useful during lung recruitment, titration of positive end-expiratory pressure, lung volume estimation, and evaluation of homogeneity of gas distribution in a single EIT measure or in combination with multiple EIT measures. EIT-guided mechanical ventilation preserved the alveolar architecture and maintained oxygenation and lung mechanics better than low-tidal volume ventilation in animal models. However, careful assessment is required for data analysis owing to the limited understanding of the results of EIT interpretation. Previous studies indicate monitoring regional ventilation by EIT is feasible in the intensive care setting and has potential to lead to lung protective ventilation. Further clinical studies are warranted to evaluate whether monitoring of regional ventilation using EIT can shorten the duration of ventilation or improve mortality in patients with acute respiratory distress syndrome.

20.
Ann Transl Med ; 6(19): 385, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30460259

RESUMO

The pressure across the lung, so-called transpulmonary pressure (PL), represents the main force acting toward to provide lung movement. During mechanical ventilation, PL is provided by respiratory system pressurization, using specific ventilator setting settled by the operator, such as: tidal volume (VT), positive end-expiratory pressure (PEEP), respiratory rate (RR), and inspiratory airway flow. Once PL is developed throughout the lungs, its distribution is heterogeneous, being explained by the elastic properties of the lungs and pleural pressure gradient. There are different methods of PL calculation, each one with importance and some limitations. Among the most known, it can be quoted: (I) direct measurement of PL; (II) elastance derived method at end-inspiration of PL; (III) transpulmonary driving pressure. Recent studies using pleural sensors in large animal models as also in human cadaver have added new and important information about PL heterogeneous distribution across the lungs. Due to this heterogeneous distribution, lung damage could happen in specific areas of the lung. In addition, it is widely accepted that high PL can cause lung damage, however the way it is delivered, whether it's compressible or tensile, may also further damage despite the values of PL achieved. According to heterogeneous distribution of PL across the lungs, the interstitium and lymphatic vessels may also interplay to disseminate lung inflammation toward peripheral organs through thoracic lymph tracts. Thus, it is conceivable that juxta-diaphragmatic area associated strong efforts leading to high values of PL may be a source of dissemination of inflammatory cells, large molecules, and plasma contents able to perpetuate inflammation in distal organs.