Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 471
Filtrar
1.
Arthroplasty ; 6(1): 44, 2024 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-39218949

RESUMO

BACKGROUND: Ligament tension balance is a major determinant for the success of total knee replacement (TKR). The present study aimed at determining the inter-rater and intra-rater reliability in performing ligament tension assessment using an imageless robotic-assisted TKR. METHODS: Twenty-four knees in 21 patients who received robotic-assisted TKR for end-stage varus osteoarthritis were examined. Three orthopedic specialists and six orthopedic trainees participated in the operations. Data from the ligament tension assessment were collected during the operations. RESULTS: For the inter-rater reliability, "extension medial" and "flexion medial" had excellent reliability whilst "extension lateral" and "flexion lateral" had good-to-excellent reliability. For the intra-rater reliability, "extension medial" showed excellent reliability, "extension lateral" and "flexion medial" showed good-to-excellent reliability, and "flexion lateral" showed moderate-to-excellent reliability. CONCLUSIONS: Robotic-assisted technology provides a reliable solution to improve ligament tension assessment. All ligament tension assessments with the use of the technology could demonstrate at least good-to-excellent reliability except for the intra-rater reliability of "flexion lateral".

2.
Cureus ; 16(8): e66096, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39224710

RESUMO

Robotic-assisted laparoscopic prostatectomy (RALP) is the surgical standard of care for patients with localized prostate cancer. Although uncommon, the procedure involves a potential risk of injury to adjacent anatomical structures. We report on a unique case of iatrogenic ureteral injury during RALP that required subsequent robotic-assisted laparoscopic ureteral reimplantation for definitive repair. A 57-year-old male underwent RALP using the Da Vinci Xi system (Intuitive Surgical, Sunnyvale, CA). The procedure was unremarkable and a 20 French Foley catheter was placed with plans for removal after one week following a negative cystogram. On postoperative day two, his creatinine level elevated to 2.69 mg/dL from a baseline of 1.40 mg/dL, left-sided flank pain increased, and non-contrast CT imaging revealed moderate left proximal hydroureteronephrosis and no other abnormalities. Aside from mild nausea on postoperative day one, he had no other symptoms. An integrated stent was unable to be placed by urology at this time. Subsequently, a left percutaneous nephrostomy tube was placed under fluoroscopic guidance. After this intervention, the patient's symptoms improved and the decision was made not to proceed with operative re-exploration at this time to attempt identification of the obstruction. Three weeks later, the patient underwent cystoscopy with attempted left retrograde ureteropyelography and left ureteroscopy due to suspected distal obstruction. This revealed complete obstruction of the intramural portion of the ureter, presumed to be secondary to suture ligation at the time of the vesicourethral anastomosis. Seven weeks postoperatively, the patient underwent robotic-assisted laparoscopic left ureteral reimplantation. Thereafter, the patient had a resolution of his left hydroureteronephrosis and acute kidney injury. This case describes an intravesical ureteral ligation during RALP. An iatrogenic intravesical ureteral ligation has far less guiding literature than a more common ureteral transection. Additionally, ureteral transection is often identified and managed intraoperatively, while the ureteral ligation presented in this case is far less likely to be apparent during surgery. Early identification will allow for rapid reoperation to manage the injury. We hypothesize that during the vesicourethral anastomosis, the left intramural ureter was ligated. Importantly, with the use of a 3-0 V-Loc stitch for the vesicourethral anastomosis, its barbed nature would not facilitate simple surgical removal. In conclusion, when performing RALP, the depth of the bladder-sided vesicourethral anastomotic stitch should be carefully considered to avoid a similar injury.

3.
Cureus ; 16(8): e66206, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39233930

RESUMO

Hernias are a common medical condition characterized by the protrusion of organs or tissues through weakened muscle walls, affecting millions worldwide annually. Historically, from being treated with open surgeries using tension-free mesh repairs, the landscape of hernia repair has evolved significantly. This evolution has been marked by the advent and refinement of minimally invasive techniques, including laparoscopic and robotic-assisted approaches, which offer reduced postoperative pain, shorter recovery times, and improved patient outcomes compared to traditional methods. This comprehensive review aims to elucidate the evolution of hernia repair techniques, emphasizing the transition from conventional mesh repairs to advanced minimally invasive methodologies. By examining the historical progression and current state of hernia surgery, this review thoroughly analyzes the advancements in surgical techniques, materials, and technologies. Furthermore, it explores emerging trends such as biological meshes, ultrasound-guided procedures, and 3D printing applications in hernia repair. The clinical significance of these advancements lies in their potential to enhance the patient's quality of life, minimize complications, and optimize healthcare resource utilization. Insights gained from this review will inform clinicians and researchers about the efficacy, safety, and comparative effectiveness of various hernia repair approaches, guiding future directions in hernia management and fostering innovation in surgical practice.

4.
Artigo em Inglês | MEDLINE | ID: mdl-39126562

RESUMO

INTRODUCTION: In robotic-assisted surgery (RAS), the input device is the primary site for the flow of information between the user and the robot. Most RAS systems remove the surgeon's console from the sterile surgical site. Beneficial for performing lengthy procedures with complex systems, this ultimately lacks the flexibility that comes with the surgeon being able to remain at the sterile site. METHODS: A prototype of an input device for RAS is constructed. The focus lies on intuitive control for surgeons and a seamless integration into the surgical workflow within the sterile environment. The kinematic design is translated from the kinematics of laparoscopic surgery. The input device uses three degrees of freedom from a flexible instrument as input. The prototype's performance is compared to that of a commercially available device in an evaluation. Metrics are used to evaluate the surgeons' performance with the respective input device in a virtual environment implemented for the evaluation. RESULTS: The evaluation of the two input devices shows statistically significant differences in the performance metrics. With the proposed prototype, the surgeons perform the tasks faster, more precisely, and with fewer errors. CONCLUSION: The prototype is an efficient and intuitive input device for surgeons with laparoscopic experience. The placement in the sterile working area allows for seamless integration into the surgical workflow and can potentially enable new robotic approaches.

5.
Arthroplasty ; 6(1): 45, 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39107828

RESUMO

BACKGROUND: One major goal of total knee arthroplasty (TKA) is to achieve balanced medial and lateral gaps in flexion and extension. While bone resections are planned by the surgeon, soft tissue laxity is largely intrinsic and patient-specific in the absence of additional soft tissue releases. We sought to determine the variability in soft tissue laxity in patients undergoing TKA. METHODS: We retrospectively reviewed 113 patients undergoing TKA. Data on preoperative knee deformity were collected. Data from a dynamic intraoperative stress examination were collected by a robotic tracking system to quantify maximal medial and lateral opening in flexion (85-95 degrees) and extension (-5-20 degrees). T-tests were used to assess the differences between continuous variables. RESULTS: A valgus stress opened the medial compartment a mean of 4.3 ± 2.3 mm (0.0-12.4 mm) in extension and 4.6 ± 2.3 mm (0.0-12.9 mm) in flexion. A varus stress opened the lateral compartment a mean of 5.4 ± 2.4 mm (0.3-12.6 mm) in extension and 6.2 ± 2.5 mm (0.0-13.4 mm) in flexion. The medial compartment of varus knees opened significantly more in response to valgus stress than valgus knees in both extension (5.2 mm vs. 2.6 mm; P < 0.0001) and flexion (5.4 mm vs 3.3 mm; P < 0.0001). The lateral compartment of valgus knees opened significantly more in response to varus stress than varus knees in both extension (6.7 mm vs. 4.8 mm; P < 0.0001) and flexion (7.4 mm vs. 5.8 mm; P = 0.0003). CONCLUSIONS: Soft tissue laxity is highly variable in patients undergoing TKA, contributing anywhere from 0-13 mm to the post-resection gap. Only a small part of this variability is predictable by preoperative deformity. These findings have implications for either measured-resection or gap-balancing techniques. LEVEL OF EVIDENCE: Level III.

6.
F1000Res ; 13: 544, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39131835

RESUMO

Background: Technology has completely transformed healthcare, starting with X-ray machines and MRIs to telehealth and robotic surgeries to e-health records. The launch of minimally invasive surgery (MIS) serves as a milestone in medical history, offering benefits such as smaller incisions, shorter hospital stays, and faster recovery, making it a preferred surgical option. This study mainly explores patients' willingness to adopt robot-assisted surgery (RAS) technology in a surgical intervention and is assessed in the backdrop of the Technology Acceptance Model (TAM). Methods: This research project employs a post-positivist research philosophy and a cross-sectional research design. A structured, pre-tested questionnaire was used to collect data from 280 respondents. Results: The results revealed that trust had a significant impact on Perceived Usefulness (ß = 0.099) and Perceived Ease of Use (ß = .157), and eHealth literacy had a significant impact on Perceived Ease of Use (ß = 0.438) and Perceived Usefulness (ß = 0.454). Additionally, Perceived Usefulness partially influenced behavioral intention (ß = 0.123), and attitude had a significant influence on behavioral intention (ß = 0.612). The analysis revealed an insignificant impact of eHealth literacy on Perceived Usefulness (ß = 0.067). The Standard Root Mean Square Residual (SRMR) value was <0.8. Mediation analysis also revealed partial mediation between the constructs. The SRMR rating of this model is 0.067, indicating that it fits the data well. Conclusion: This study revealed that a patient's intention will be high if he or she believes that RAS is beneficial in treating his or her ailment. In comparison, information related to RAS is clearly known, and it does not directly affect selection intention. eHealth literacy is a significant antecedent to patients' behavioral intention. Hence, the healthcare industry must devise strategies to promote the acceptance of RAS at all levels.

7.
Artigo em Inglês | MEDLINE | ID: mdl-39193722

RESUMO

The standard treatment for primary mediastinal yolk sac tumour involves neoadjuvant chemotherapy followed by residual tumour resection, typically performed through a median sternotomy or a thoracotomy. However, in this case, a 16-year-old patient with a large anterior mediastinal tumour underwent less invasive, subxiphoid, robot-assisted surgery using a 4-arm da Vinci Xi system with CO2 insufflation at 8 mmHg. The tumour, located in the right thymic lobe, was dissected using a technique similar to blunt dissection, bipolar electrocautery and vessel sealer. Pericardiotomy was performed suspecting tumour invasion, with the thickened pericardial border incised circularly from the left side. Preservation of the right phrenic nerve involved careful separation from the densely adherent tumour. A pulmonary wedge resection was also performed using a stapler. The pericardial defect was reconstructed using an expanded polytetrafluoroethylene sheet, sutured together with nylon threads, and the resected tumour was extracted with a retrieval bag. This subxiphoid robot-assisted approach is a minimally invasive option for malignant mediastinal tumours.


Assuntos
Tumor do Seio Endodérmico , Neoplasias do Mediastino , Procedimentos Cirúrgicos Robóticos , Humanos , Tumor do Seio Endodérmico/cirurgia , Tumor do Seio Endodérmico/diagnóstico , Tumor do Seio Endodérmico/tratamento farmacológico , Neoplasias do Mediastino/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Adolescente , Masculino , Resultado do Tratamento
8.
Obes Surg ; 34(9): 3561-3568, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39090429

RESUMO

BACKGROUND: In laparoscopic surgery, telerobotic systems such as Da Vinci™ were developed, among other things, to give back exposure and vision control to the operating surgeon. However, new limitations such as the separation of the operating surgeon from the operating table, cost, and size were unveiled. A new device, Maestro™, appears promising in addressing these limitations. The current work evaluates the feasibility, safety, and surgeon satisfaction with the assistance provided by the Maestro System. METHODS: Non-consecutive patients who were candidates for laparoscopic digestive surgery were enrolled in a descriptive prospective, monocentric study. Case selection was solely based on the availability of the device, but not on the patient's characteristics. Surgery was performed by a leading surgeon with the help of one less experienced surgeon. Feasibility was defined by the maintenance of the initial surgical plan. Safety was assessed by the absence of serious adverse events related to the device and surgeon satisfaction was evaluated by a questionnaire following the intervention. RESULTS: All 50 procedures were completed without conversion in laparotomy and without adjustment of the surgical team. Four complications were recorded during the study; however, none related to the use of the Maestro System. In 92% of the cases, the surgeon was satisfied with the assistance provided by the Maestro System. CONCLUSIONS: In standard elective digestive procedures by laparoscopy, the use of the Maestro System is feasible and safe. It is beneficial to the surgeon and operative room organization by limiting the size of the surgical team.


Assuntos
Estudos de Viabilidade , Laparoscopia , Procedimentos Cirúrgicos Robóticos , Humanos , Laparoscopia/métodos , Feminino , Estudos Prospectivos , Masculino , Pessoa de Meia-Idade , Adulto , Idoso
9.
World Neurosurg ; 2024 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-39216720

RESUMO

Japanese neurosurgery faces challenges such as a declining number of neurosurgeons and their concentration in urban areas. Particularly in rural areas, access to neurosurgical care for patients with conditions, such as stroke, is limited, raising concerns about the collapse of regional healthcare. Robot-assisted surgical technologies have advanced in recent years, contributing to the improved precision and safety of deep brain surgery. This study proposes the "Artificial Intelligence (AI) and Robot-Assisted Surgery Moonshot Plan" for Japan, comprising five pillars: 1) establishment of regional medical centers, 2) development of remote surgery systems, 3) enhancement of robotic-assisted surgery training programs, 4) integration of artificial intelligence technologies, and 5) promotion of industry-academia-government collaboration. In addition, strengthening the approach to spinal surgery is expected to revitalize regional medical centers, optimize the number of neurosurgeons, improve surgical skills, and promote minimally invasive surgery. This study analyzed the current status and challenges of Japanese neurosurgery through a literature review and statistical analysis. AI is used in various aspects of neurosurgery, including diagnostic support, surgical planning and navigation, treatment outcome prediction, intraoperative monitoring, robot-assisted surgery, and rehabilitation. However, challenges, such as data bias, ethical issues, costs, and regulations, remain. In Japan, issues such as the uneven distribution and decline of neurosurgeons, collapse of regional healthcare, and increase in the number of patients with spinal disorders due to aging have been highlighted. The "AI and Robot-Assisted Surgery Moonshot Plan" serves as a guide to overcome the challenges of neurosurgery in Japan and establish a sustainable medical system.

10.
Rev Mal Respir ; 2024 Aug 28.
Artigo em Francês | MEDLINE | ID: mdl-39209563

RESUMO

BACKGROUND: The aim of this work is to assess the quality of observational studies and to make direct and indirect comparisons of robotic surgery with other approaches. METHOD: We searched various databases between 2014 and 2024 for observational studies comparing robotic-assisted surgery to thoracoscopy or thoracotomy. RESULTS: Eighteen studies were included in the meta-analysis. Risk of confounding bias was present in 90% of studies, while risk of classification bias appeared in 80%. Robotic-assisted surgery reduced the risk of conversion to thoracotomy compared with thoracoscopy with an odds ratio of 0.21 (95% confidence interval: 0.06-0.65), with high heterogeneity between studies (I2=80%). Robotic-assisted surgery did not significantly reduce postoperative complications or 30-day mortality compared with thoracotomy or thoracoscopy. For 5-year overall survival, comparisons of robotic-assisted surgery to thoracoscopy or thoracotomy were non-significant with I2 of 55%. CONCLUSION: This work demonstrates the need for a randomized controlled trial to validate robotic surgery for the treatment of bronchial cancer.

11.
Children (Basel) ; 11(8)2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39201870

RESUMO

BACKGROUND: Robotic-assisted surgery (RAS) holds many theoretical advantages, especially in pediatric surgical procedures. However, most robotic systems are dedicated to adult surgery and are less suitable for smaller children. The Senhance® Surgical System (SSS®), providing 3 mm and 5 mm instruments, focuses on making RAS technically feasible for smaller children. This prospective observational study aims to assess whether RAS in pediatric patients using the SSS® is safe and feasible. METHODS AND RESULTS: A total of 42 children (aged 0-17 years, weight ≥ 10 kg) underwent a RAS procedure on the abdominal area using the SSS® between 2020 and 2023. The study group consisted of 20 male and 22 female individuals. The mean age was 10.7 years (range 0.8 to 17.8 years), with a mean body weight of 40.7 kg (range 10.1 to 117.3 kg). The 3-mm-sized instruments of the SSS® were used in 12 of the 42 children who underwent RAS. The RAS procedures were successfully completed in 90% of cases. The conversion rate to conventional laparoscopy was low (10%), and there were no conversions to open surgery. One of the 42 cases (2%) experienced intraoperative complications, whereas six children (14%) suffered from a postoperative complication. Overall, 86% of the patients had an uncomplicated postoperative course. CONCLUSIONS: The results of the current observational study demonstrate the safety and feasibility of utilizing the SSS® for abdominal pediatric RAS procedures. The study provides new fundamental information supporting the implementation of the SSS® in clinical practice in pediatric surgery.

12.
Surg Obes Relat Dis ; 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38991936

RESUMO

BACKGROUND: Sleeve gastrectomy (SG) is the most commonly performed metabolic and bariatric surgery (MBS) procedure. Technical considerations related to the performance of SG are well established and reported in the literature but not in relation to robotic-assisted (RA) SG. We report the results of the first modified Delphi consensus-building exercise addressing technical considerations of RA da Vinci (dV) SG. OBJECTIVES: Develop best practices for the performance of robotic-assisted da Vinci sleeve gastrectomy. SETTING: Survey based consensus statement. METHODS: A consensus building committee (CBC) was created comprising 10 experts in the field of RA surgery and MBS based on strict selection criteria. The CBC developed 49 consensus statements which were then shared with 240 experts in RA surgery. Our stopping criterion was stability in responses (≤15%). The consensus cut point was 70%. RESULTS: The overall response rate was 49%. In the first round of voting, there was consensus agreement on 25 statements (51%), consensus disagreement on 14 (28%), and no consensus on the remaining statements (21%). In the second round of voting, we reached agreement on 3 additional statements. Experts recommended the use of the number of pauses generated by the stapler to guide choice of staple height (91.2%) and to upsize the staple height when using buttressing (92%). There was also consensus (81.4%) that the use of the closed staple height of 1.00 mm (white) is acceptable and that stapling of the antrum using a 1.5-mm staple (blue load) is also acceptable (73%). CONCLUSIONS: Collective expert opinion structured through a modified Delphi consensus statement presents a practical guide for surgeons interested in performing dV-SG.

13.
J Robot Surg ; 18(1): 273, 2024 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-38949665

RESUMO

Robotic assistance for total hip arthroplasty (THA) has been demonstrated to improve accuracy of acetabular cup placement relative to manual, unassisted technique. The purpose of this investigation was to compare the accuracy and precision between a fluoroscopy-based robotic total hip arthroplasty platform (FL-RTHA) and a computerized tomography-based (CT-RTHA) platform. The study included 98 consecutive FL-RTHA and 159 CT-RTHA procedures performed via direct anterior approach (DAA). All cases were performed for a pre-operative diagnosis of osteoarthritis, avascular necrosis, or rheumatoid arthritis. Primary outcome variables included cup implantation accuracy and precision (variance). Implantation accuracy was calculated as the absolute value of the difference between pre-operative target cup angles (inclination and anteversion) and the same post-operative angles. Percentage placement in the Lewinnek safe zone was also measured for both cohorts. The FL-RTHA and CT-RTHA cohorts demonstrated a 1.2° difference in absolute values for cup inclination accuracy (4.6° ± 3.6 vs. 3.4 ± 2.7; p = 0.005), and no difference in absolute values for cup anteversion accuracy (4.7° ± 4.1 vs. 4.6 ± 3.4; p = 0.991). Cohorts demonstrated similar precision for cup inclination and anteversion placement parameters, as well as equivalent Lewinnek safe zone placement. The use of a fluoroscopy-based robotic assistance platform for primary DAA THA resulted in similar accuracy and precision of acetabular cup placement when compared to a CT-based robotic assistance system.


Assuntos
Artroplastia de Quadril , Procedimentos Cirúrgicos Robóticos , Tomografia Computadorizada por Raios X , Humanos , Artroplastia de Quadril/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Fluoroscopia/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Prótese de Quadril , Acetábulo/cirurgia , Acetábulo/diagnóstico por imagem , Cirurgia Assistida por Computador/métodos
14.
Int Urogynecol J ; 2024 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-39002047

RESUMO

INTRODUCTION AND HYPOTHESIS: We describe the surgical management of intravesical mesh perforation following transvaginal mesh surgery for pelvic organ prolapse. METHODS: A 73-year-old woman presented with intravesical mesh perforation 17 years following transvaginal mesh-based prolapse repair at an outside hospital. The patient presented with intermittent hematuria and recurrent urinary tract infections. Cystoscopy demonstrated an approximately 3-cm area of intravesical mesh with associated stone spanning from the bladder neck through the left trigone and ureteral orifice. A robotic-assisted transvesical mesh excision and left ureteroneocystostomy was carried out. Robotic-assisted repair was performed transvesically via transverse bladder dome cystotomy. Dissection was carried out circumferentially around the mesh in the vesicovaginal plane, including a 1-cm margin of healthy tissue. The eroded mesh was excised, and the vaginal wall and bladder were closed with running absorbable sutures. Given the location of the mesh excision and repair, a left ureteral reimplantation was performed. The transverse cystotomy was closed and retrograde bladder filling with methylene blue-stained saline confirmed watertight repairs, with no vaginal extravasation. RESULTS: The patient was discharged the following morning and had an uneventful recovery, including transurethral indwelling catheter removal at 2 weeks after CT cystogram and subsequent ureteral stent removal at 6 weeks postoperatively. At 2-month follow-up she had no new urinary symptoms or obstruction of the ureteral reimplantation on renal ultrasound. CONCLUSIONS: A robotic-assisted approach is a feasible option for managing transvaginal prolapse mesh perforation into the bladder. Pelvic surgeons must be well equipped to handle transvaginal mesh complications in a patient-specific manner.

15.
Radiol Case Rep ; 19(9): 4059-4065, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39076885

RESUMO

Non-steroidal anti-inflammatory drugs (NSAIDs) are commonly used for their analgesic and anti-inflammatory effects but can lead to serious gastrointes complications. This report illustrates the management of an NSAID-induced penetrating gastric ulcer with subsequent postoperative hemorrhagic cholecystitis. A 68-year-old female with chronic NSAID use presented with epigastric pain and was diagnosed with a penetrating gastric ulcer extending into the retroperitoneum. The surgical management required a shift from a minimally invasive robotic-assisted approach to an open procedure due to unexpected intraoperative findings. The postoperative period was notable for the development of hemorrhagic cholecystitis that was managed with percutaneous transhepatic biliary drainage, highlighting the role of interventional radiology in complex postoperative care. NSAID use significantly increases gastrointestinal risks, leading to complications such as ulcers that may penetrate into adjacent structures, including the retroperitoneum. The management of penetrating gastric ulcers typically involves complex surgical procedures, highlighted in this scenario by the necessity for an antrectomy followed by a Billroth II reconstruction to address the extensive damage and restore gastrointestinal continuity, which is essential for patient recovery. In this case, the development of hemorrhagic cholecystitis postoperatively was effectively managed with a percutaneous transhepatic biliary drain, demonstrating the importance of interventional radiology in managing postoperative complications and the need for a multidisciplinary approach. This case report elucidates the management of NSAID-induced penetrating gastric ulcer that extended into the retroperitoneum, necessitating an antrectomy with Billroth II reconstruction. A gastric ulcer is generally classified as "large" if it exceeds 2 centimeters in diameter. These ulcers pose greater risks of complications such as perforation, penetration into adjacent organs, bleeding, and obstruction, necessitating more complex and comprehensive management strategies. The postoperative complication of hemorrhagic cholecystitis was effectively managed via interventional radiology, highlighting the critical role of minimally invasive techniques in addressing severe postoperative complications.

16.
Cureus ; 16(6): e63226, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39070522

RESUMO

Osteoporosis significantly impairs bone density and increases fracture risk, representing a substantial global health challenge. The effectiveness of traditional treatments such as calcium supplementation and exercise in completely preventing fractures is limited. This review explores recent advancements in surgical techniques and treatment modalities to manage osteoporotic fractures better and improve patient outcomes. Osteoporotic fractures demand specialized surgical techniques due to compromised bone quality. Vertebroplasty and kyphoplasty are minimally invasive procedures that provide rapid pain relief and structural support using bone cement. While vertebroplasty is effective, it carries risks of cement leakage and new fractures. Kyphoplasty, with added balloon inflation, reduces leakage risk and improves vertebral height restoration but is costlier. Cement-augmented screws enhance fixation but can increase adjacent fracture risk and pose long-term complications. Surgical advancements encompass robotic-assisted surgery, offering precision and accelerated recovery, alongside biologic agents like bone morphogenetic proteins (BMPs), which enhance bone healing while reducing secondary interventions and eliminating donor site morbidity. Bone graft substitutes such as calcium phosphate cements enhance biomechanical compatibility, decrease morbidity, and reduce fracture loss and pain. Balloon kyphoplasty aids in height restoration and pain relief and diminishes the risk of subsequent vertebral fractures. Bioglass scaffolds promote bone regeneration by improving bone mineral density and lowering the incidence of new fractures. Optimal perioperative care, including patient selection, nutritional management, and early mobilization strategies, is crucial for mitigating risks in vulnerable populations. While current surgical interventions provide significant pain relief and functional benefits, ongoing research and multidisciplinary collaboration are crucial to prospectively refine these techniques and reduce the burden of osteoporosis. New technologies, such as tissue engineering and gene editing, hold potential for future treatment paradigms.

17.
Cureus ; 16(6): e63488, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39081431

RESUMO

Appendectomy ranks among the most common surgical procedures. Laparoscopic appendectomy has become increasingly popular among certain surgeons. Even laparoscopic appendectomy is considered the gold standard; many surgical subspecialties have adopted robotic surgery in the past 10 years. The robotic system is recognized for enhancing stability, visualization, precision, and spatial flexibility. Surgeons can operate with enhanced dexterity, reduced tremors, three-dimensional visualization, up to 10 times magnification, and control over four arms thanks to improved ergonomics that allow them to sit at a customizable console. The purpose of this study is to evaluate and compare the overall effects, such as intraoperative time, postoperative recovery, feasibility for surgeons, and cost-effectiveness, of robotic-assisted appendectomy and laparoscopic appendectomy through the available literature. It was found that both robotic and laparoscopic surgeries work well for appendectomy, but in some studies, it was found that robotic surgery comes with the perks of shorter hospital stays and quicker recovery, even though it is more expensive, and in some studies, no differences were observed in patient recovery postoperatively. Laparoscopic surgery is still a highly effective and commonly used method, with proven advantages over open appendectomy, despite taking longer for the procedure. We need more studies to fully understand the advantages and disadvantages of robotic surgery, especially when it comes to cost-effectiveness and wider health outcomes.

18.
Cureus ; 16(7): e63771, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38966780

RESUMO

Lumbar hernias are rare abdominal wall hernias that occur in the posterolateral abdominal wall. Intra-peritoneal or extra-peritoneal contents typically protrude through defects in one of two anatomical triangles. The superior lumbar triangle (Grynfeltt-Lesshaft triangle) is an inverted triangle bordered by the 12th rib superiorly, the internal oblique muscle laterally, and the erector spinae muscle medially. The inferior lumbar triangle (Petit's triangle) is an upright triangle bordered by the iliac crest inferiorly, the external oblique muscle laterally, and the latissimus dorsi muscle medially. Surgical repair has been described via open or laparoscopic approach. A 69-year-old male patient presented with right flank pain and swelling. He was involved in a motorcycle accident 10 months prior, which likely resulted in the development of a traumatic lumbar hernia which was demonstrated on the CT scan. The hernia was clinically incarcerated, and the defect contained the cecum and ileocecal valve. The defect was noted just superior to the iliac crest, by definition, making this an inferior lumbar hernia or a Petit's hernia. The hernia was repaired via robotic-assisted laparoscopic transabdominal approach. A peritoneal flap was created exposing the fascial defect. The fascia was primarily repaired with suture. The defect was reinforced with an 11.4 cm round Ventralight ST mesh in the preperitoneal space. The patient tolerated the procedure well with no acute complications. He was discharged the same day as an outpatient with appropriate pain control. Short-term follow-up demonstrated no recurrent hernia present and symptoms resolved. Lumbar hernias are a rare occurrence with no gold standard technique for repair. The benefits of the laparoscopic approach have been described over the open approach. This case report describes utilizing a minimally invasive approach to primarily repair a lumbar hernia defect while also reinforcing the hernia with mesh in the preperitoneal space.

19.
Artigo em Inglês | MEDLINE | ID: mdl-38992749

RESUMO

STUDY OBJECTIVE: To characterize robotic surgery publications in gynecologic oncology, and to identify factors associated with high citation metrics. DESIGN: A cross-sectional study SETTING: Original articles on robotic surgery in gynecologic oncology. PATIENTS: No patients involved. INTERVENTIONS: Robotic surgeries in gynecologic oncology. MEASUREMENTS AND MAIN RESULTS: We performed PubMed Medical Subject Headings search for original articles on robotic surgery in gynecologic oncology. We analyzed citation scores and income level of country of publication, as well as factors associated with high citation metrics. Overall, 566 studies during 2005 to 2023 were included. Of those 292, 51.6% were from North America, and 182 32.2% from Europe. The leading tumor site studied was endometrial cancer (57.4%). The majority (87.6%) of studies were retrospective and 13 (2.3%) were randomized controlled trials. Most studies (94.2%) originated in high-income countries. Articles from middle-income countries had lower citations per year as compared to high-income countries (median 1.6 vs 2.5, p =.002) and were published in lower-impact factor journals (median 2.6 vs 4.3, p < .001) when compared with high-income countries. Cervical cancer studies had higher representation in middle-income countries than in high-income countries (48.5% vs 18.4%, p < .001). In a multivariable regression analysis, journal's impact factor [aOR 95% CI 1.26 (1.12-1.40)], cervical cancer topic [aOR 95% CI 3.0 (1.58-5.91)], and North American publications [aOR 95% CI 2.07 (1.08-3.97)] were independently associated with higher number of citations per year. CONCLUSION: The majority of robotic surgery research in gynecologic oncology is retrospective and from high-income countries. Middle-income countries are not as frequently cited and are predominantly in lower-impact factor journals.

20.
Cureus ; 16(6): e62958, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39050344

RESUMO

The modern hospital setting is closely related to engineering and technology. In a hospital, modern equipment is abundant in every department, including the operating room, intensive care unit, and laboratories. Thus, the quality of treatment provided in hospitals and technology advancements are closely tied. Robotic systems are used to support and improve the accuracy and agility of human surgeons during medical procedures. This surgical approach is commonly referred to as robotic surgery or robotic-assisted surgery (RAS). These systems are not entirely autonomous; they are managed by skilled surgeons who carry out procedures with improved accuracy and minimized invasiveness using a console and specialized instruments. Because RAS offers increased surgical precision, less discomfort after surgery, shorter hospital stays, and faster recovery time, all of which improve patient outcomes and lessen the strain on healthcare resources, it plays a critical role in public health. Its minimally invasive technique benefits patients and the healthcare system by lowering problems, reducing the requirement for blood transfusions, and reducing the danger of infections related to medical care. Furthermore, the possibility of remote surgery via robotic systems can increase access to specialized care, reducing regional differences and advancing fairness in public health. In this review article, we will be covering how RAS has its role in public health.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA