Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adv Healthc Mater ; 12(2): e2202106, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36250334

RESUMO

Inadequate mechanical compliance of orthopedic implants can result in excessive strain of the bone interface, and ultimately, aseptic loosening. It is hypothesized that a fiber-based biometal with adjustable anisotropic mechanical properties can reduce interface strain, facilitate continuous remodeling, and improve implant survival under complex loads. The biometal is based on strategically layered sintered titanium fibers. Six different topologies are manufactured. Specimens are tested under compression in three orthogonal axes under 3-point bending and torsion until failure. Biocompatibility testing involves murine osteoblasts. Osseointegration is investigated by micro-computed tomography and histomorphometry after implantation in a metaphyseal trepanation model in sheep. The material demonstrates compressive yield strengths of up to 50 MPa and anisotropy correlating closely with fiber layout. Samples with 75% porosity are both stronger and stiffer than those with 85% porosity. The highest bending modulus is found in samples with parallel fiber orientation, while the highest shear modulus is found in cross-ply layouts. Cell metabolism and morphology indicate uncompromised biocompatibility. Implants demonstrate robust circumferential osseointegration in vivo after 8 weeks. The biometal introduced in this study demonstrates anisotropic mechanical properties similar to bone, and excellent osteoconductivity and feasibility as an orthopedic implant material.


Assuntos
Materiais Biocompatíveis , Oligoelementos , Camundongos , Animais , Ovinos , Titânio , Microtomografia por Raio-X , Próteses e Implantes , Teste de Materiais , Osseointegração , Porosidade
2.
Adv Mater ; 30(4)2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29215204

RESUMO

Titanium plates are widely used in clinical settings because of their high bone affinity. However, owing to their high elastic modulus, these plates are not suitable for bone repair since their proximity to the bone surface for prolonged periods can cause stress shielding, leading to bone embrittlement. In contrast, titanium fiber plates prepared by molding titanium fibers into plates by simultaneously applying compression and shear stress at normal room temperature can have an elastic modulus similar to that of bone cortex, and stress shielding will not occur even when the plate lies flush against the bone's surface. Titanium fibers can form a porous structure suitable for cell adhesion and as a bone repair scaffold. A titanium fiber plate is combined with osteoblasts and shown that the titanium fiber plate is better able to facilitate bone tissue repair than the conventional titanium plate when implanted in rat bone defects. Capable of being used in close contact with bone for a long time, and even capable of promoting bone repair, titanium fiber plates have a wide range of applications, and are expected to make great contributions to clinical management of increasing bone diseases, including bone fracture repair and bone regenerative medicine.


Assuntos
Titânio/química , Placas Ósseas , Osso e Ossos , Porosidade , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA