Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Am J Ophthalmol ; 242: 69-76, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35654121

RESUMO

PURPOSE: Investigate associations of race/ethnicity and preferred language with baseline glaucoma severity, VF test frequency and disease progression. DESIGN: Retrospective cohort study. METHODS: Patients receiving VF testing at a tertiary eyecare center between 1998 and 2020 with self-identified race, ethnicity and preferred language were included. Outcome measures were VF MD and age at first visit, VF test frequency, VF MD progression. RESULTS: Among 29,891 patients with VF measurements between 1998 and 2020, 55.1% were female, 71.0% self-identified as White/Caucasian, 14.0% as Black/African American, 7.4% as Asian and 6.4% as Hispanic, and 11.2% preferred a language other than English. Mean VF MD at presentation was worse among Black (-9.3±9.7 dB), Asian (-6.2±7.6 dB) and Hispanic (-8.3±9.3 dB) patients (vs. Whites [-5.5±7.3 dB, p<0.001] or non-Hispanics [-6.2±7.8 dB, p<0.001]). After controlling for age, gender and English proficiency, disparities in glaucoma severity at presentation were reduced, especially among Asian and Hispanic patients. Despite greater severity at presentation, Black patients had lower VF test frequency/person-years (1.07±0.53) compared to Whites (1.12±0.52, p=0.006) and worse VF MD progression (-0.43 dB/year, 95% CI -0.67 to -0.28, p<0.001). In contrast, Hispanics had a higher VF frequency vs. non-Hispanics (1.18±0.64 vs. 1.11±0.52, p<0.001), and no difference in VF progression (p=0.77). CONCLUSIONS: Black, Asian and Hispanic patients had greater baseline severity vs. Whites. Unlike other groups, Black patients had a lower VF frequency vs. Whites and greater VF progression. Disparities in baseline severity were partially explained by English proficiency, especially for Asian and Hispanic patients.


Assuntos
Glaucoma , Campos Visuais , Progressão da Doença , Etnicidade , Feminino , Glaucoma/diagnóstico , Humanos , Pressão Intraocular , Masculino , Estudos Retrospectivos , Índice de Gravidade de Doença , Transtornos da Visão , Testes de Campo Visual
2.
Clin Ophthalmol ; 15: 4455-4465, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34819717

RESUMO

PURPOSE: To investigate features of the steady-state pattern electroretinogram (ssPERG) in subjects with glaucoma (G), high myopia (HM; spherical equivalent ≤-6D) and glaucoma with high myopia (GHM). PATIENTS AND METHODS: Our study included 48 participants divided into 3 groups (G, HM, and GHM) who each underwent monocular ssPERG testing with Diopsys NOVA PERG protocols. The ConStim protocol detects distinct topographic patterns of dysfunction 16° and 24° around the central macula. MagD is the amplitude of the average signal and MagD/Mag ratio indicates the consistency of the response. ssPERG indices were compared between groups and correlated with functional (ie, visual field mean deviation (VFMD)) and structural (ie, average retinal nerve fibre layer (RNFL) thickness; Cirrus optical coherence tomography) features. RESULTS: Participants had an average age of 59.4±7.6 years. Mean Humphrey VFMD was -14.22 ± 2.88dB, -2.62 ± 1.18dB and -12.80 ± 2.60dB for G, HM and GHM groups, respectively. Mean RNFL thickness was 63.0 ± 8.20µm, 69.5 ± 15.7µm and 60.6 ± 5.0µm for G, HM and GHM groups, respectively. For the 24° setting, no significant differences were noted for any of the parameters. For the 16° setting, MagD was lower in the GHM group compared to the HM group (0.29µV vs 0.52µV; p = 0.02). Significant differences were noted for the MagD/Mag ratio between HM and G groups (0.58 vs 0.40; p = 0.02) and between HM and GHM groups (0.58 vs 0.35; p = 0.002). There were positive correlations between both MagD 16° and MagD/Mag ratio 16° with VFMD (correlation coefficient [r]=0.37, p = 0.009; and r = 0.44, p = 0.002, respectively) and RNFL (r = 0.43, p = 0.002; and r = 0.48, p = 0.001, respectively). CONCLUSION: MagD/Mag ratio at 16° was significantly lower in glaucomatous eyes (with or without high myopia) compared to those with high myopia without glaucoma, suggesting that glaucoma has a distinct impact on MagD/Mag ratio at 16° irrespective of the presence of myopia.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA