Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 160
Filtrar
1.
Jpn J Radiol ; 2024 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-39259419

RESUMO

OBJECTIVE: To evaluate the usefulness of novel diffusion-weighted imaging (DWI) findings for diagnosing placenta accreta spectrum (PAS). MATERIALS AND METHODS: This retrospective study included 49 pregnant women with suspected PAS who underwent 1.5 T placental MRI. Diffusion lacunae were defined as intraplacental areas showing hypointensity on DWI and hyperintensity on the apparent diffusion coefficient map. Two radiologists evaluated the number and size of placental lacunae on DWI, and flow void in the diffusion lacunae on T2-weighted imaging. The radiologists also evaluated established MRI features of PAS described in the SAR-ESUR consensus statement. Pearson's chi-square test or Mann-Whitney U test was used to compare findings between patients with and without PAS. Interobserver reliability for DWI and established MRI features was also assessed. Optimal thresholds for the number and maximum size of diffusion lacunae for differentiating PAS from the no-PAS group were determined using receiver operating characteristic curve analyses. RESULTS: Eighteen patients were diagnosed with PAS, and 31 patients with placental previa without PAS. The number and maximum size of diffusion lacunae were significantly larger in patients with than in patients without PAS (p < 0.0001). Combining assessment of the number of diffusion lacunae with assessment of their maximum size yielded a diagnostic performance with sensitivity, specificity and accuracy of 83%, 94% and 90%, respectively. Flow voids within the diffusion lacunae had sensitivity, specificity and accuracy of 88%, 84% and 86%, respectively. CONCLUSION: The number and size of diffusion lacunae, and T2 flow void in diffusion lacunae may be useful findings for diagnosing PAS.

2.
Materials (Basel) ; 17(15)2024 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-39124537

RESUMO

This paper investigates the impact of element size on the microstructure of the steel-concrete interface in self-compacting concrete (SCC). Experiments were conducted on two types of test elements: a deep beam measuring 1440 × 640 × 160 mm and a wall element measuring 2240 × 1600 × 160 mm. The SCC mix was consistently pumped from the top, using a single casting point located near the formwork's edge. Horizontal steel ribbed rebars with a diameter of 16 mm were embedded in these elements. X-ray computed tomography (CT) was employed to provide three-dimensional insights into the microstructure of the rebar-to-concrete interface. An analysis of X-ray CT images from core samples revealed that the microstructure of this interface is influenced by the distance of the specimen from the mix casting point and its vertical position within the element. The combined effects of bleeding, air-pore entrapment, and plastic settlement within the SCI were observed under the top rebars. Their extent was independent of the type of element analyzed, suggesting that the deterioration of the SCI is related to the distance from the top surface of the element. These results elucidate phenomena occurring during the fresh state of concrete near reinforcing bars and their implications for bond properties. To date, some of the standards differentiate between bond conditions according to the depth of concrete beneath the rebar. In the view of the studies, this approach may be unduly rigorous. The findings offer valuable guidance for reinforced concrete execution and design.

3.
Rinsho Shinkeigaku ; 64(8): 572-578, 2024 Aug 27.
Artigo em Japonês | MEDLINE | ID: mdl-39048380

RESUMO

We describe a 44-year-old man with a complaint of atonic seizures of the left upper limb, followed by generalized seizures. Brain MRI showed isolated juxtacortical white matter T2 hyperintensity with gadolinium (Gd) enhancement of the adjacent cortical gray matter and subcortical white matter in the right frontal convexity. Treatment with levetiracetam was effective for seizure suppression, and he had no other neurological abnormalities. Human leukocyte antigen typing revealed B54 and Cw1, which indicated the possibility of neuro-Sweet disease. However, a general examination, which included vital signs and eye and skin findings, was normal. A cerebrospinal fluid test showed a mild elevation in protein levels without pleocytosis and a normal range of interleukin-6. Electroencephalography showed intermittent slow waves without epileptic discharge in the bilateral temporal lobes. We detected subtle flow voids in the pia mater of the left frontal lobe, which suggested cerebrovascular disease, and specifically, the possibility of dural arteriovenous fistulas. Computed tomography angiography showed abnormally dilated perimedullary veins in the left frontal lobe. Cerebral angiography confirmed the existence of four dural arteriovenous fistulas, which included two retrograde leptomeningeal venous drainages in the right frontal cortical veins supplied by the anterior branch of the right middle meningeal artery. The other dural arteriovenous fistulas were retrograde leptomeningeal venous drainages in the left frontal cortical veins supplied by the anterior and posterior convexity branches of the left middle meningeal artery. The patient underwent successful endovascular embolization of all dural arteriovenous fistulas with Onyx injection. A follow-up MRI showed gradual improvement of the T2 hyperintensity and Gd enhancement. He remained seizure-free for 2 years following endovascular embolization.


Assuntos
Malformações Vasculares do Sistema Nervoso Central , Angiografia Cerebral , Gadolínio , Levetiracetam , Imageamento por Ressonância Magnética , Substância Branca , Humanos , Masculino , Adulto , Malformações Vasculares do Sistema Nervoso Central/diagnóstico por imagem , Malformações Vasculares do Sistema Nervoso Central/terapia , Gadolínio/administração & dosagem , Substância Branca/diagnóstico por imagem , Substância Branca/patologia , Levetiracetam/administração & dosagem , Convulsões/etiologia , Lobo Frontal/diagnóstico por imagem , Lobo Frontal/irrigação sanguínea , Lobo Frontal/patologia , Piracetam/administração & dosagem , Piracetam/análogos & derivados , Meios de Contraste/administração & dosagem , Tomografia Computadorizada por Raios X
4.
Int J Biol Macromol ; 277(Pt 1): 134159, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39059540

RESUMO

The development of high-performance biodegradable polylactic acid (PLA) materials integrating high strength, malleability and toughness is desired but an ongoing challenge. In this work, a novel full-biobased block copolymer was designed and synthesized by grafting L (+)-lactide (L-LA) and ε-caprolactone (ε-CL) onto lignin via ring-opening polymerization. The obtained lignin-PLA-PCL block copolymer was composed of rigid lignin and poly (LA-CL) rubber segment, could self-assemble into uniform nano-micelles with average diameters of 80-100 nm regulated by simply altering copolymer content. The incorporation of lignin-PLA-PCL copolymers into PLA matrix induced the formation of many cavities, promoted free volume between PLA matrix and copolymer to accelerate chain mobility, achieving excellent ductility and stretchability with maximum stretching deformation of 64.8 %. The resultant PLA composites with the copolymer content as low as 5 wt% displayed simultaneously improved strength (41.84 MPa) and toughness (8.1 MJ/m3), 6.7 % and 1520 % increment than those of neat PLA, respectively. The reinforcing and toughening mechanisms were explored and verified that the combination of cavity growth and fibrillation, followed by extensive shear yielding of matrix, causing substantial plastic deformation. This study extended the design strategy and the foundation for simultaneous reinforcing and toughening PLA plastics using lignin-derived rubbery micelles.


Assuntos
Lignina , Micelas , Poliésteres , Lignina/química , Poliésteres/química , Resistência à Tração , Polimerização
5.
Sensors (Basel) ; 24(13)2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-39000961

RESUMO

Additive Manufacturing (AM) Direct Laser Fabrication (DLF) of Ti-5Al-5V-5Mo-3Cr (Ti5553) is being developed as a method for producing aircraft components. The additive manufacturing process can produce flaws near the surface, such as porosity and material voids, which act as stress raisers, leading to potential component failure. Eddy current testing was investigated to detect flaws on or near the surface of DLF Ti5553 bar samples. For this application, the objective was to develop an eddy current probe capable of detecting flaws 500 µm in diameter, located 1 mm below the component's surface. Two initial sets of coil parameters were chosen: The first, based on successful experiments that demonstrated detection of a near surface flaw in Ti5553 using a transmit-receive array probe, and the second, derived from simulation by Finite Element Method (FEM). An optimized transmit receive coil design, based on the FEM simulations, was constructed. The probe was evaluated on Ti5553 samples containing sub-surface voids of the target size, as well as samples with side-drilled holes and samples with holes drilled from the opposing inspection surface. The probe was able to effectively detect 80% of the sub-surface voids. Limitations included the probe's inability to detect sub-surface voids near sample edges and a sensitivity to surface roughness, which produces local changes in lift-off. Multifrequency mixing improved signal-to-noise ratio when surface roughness was present on average by 22%. A probe based on that described in this paper could benefit quality assurance of additively manufactured aircraft components.

6.
Heliyon ; 10(13): e33625, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39040395

RESUMO

The presence of voids in a solder layer affects the thermal reliability of an insulated-gate bipolar transistor (IGBT). In this work, the effects of the size and fraction of solder layer voids and the power losses of chips on heat flow distribution, junction temperature and thermal resistance were investigated. It was found that it was difficult for the heat to flow through the voids due to the high thermal resistance of air. Therefore, the heat above the voids could only flow horizontally, and then avoid the voids and move downward in the solder layer and the following layers, leading to a temperature difference in the surface chip layer. An improved junction temperature model based on the heat flow distribution (HD) considering the solder layer voids was established, the horizontal thermal resistance and horizontal heat capacity are introduced to characterize the effect of the solder layer voids, and the parameter extraction method was proposed. The temperature difference on the surface of the module increased with the increase of the void fraction, and when the void fraction increased from 0 % to 40 %, the surface temperature difference increased from 9.591 °C to 109.86 °C. The results showed that the proposed model not only had a higher accuracy in the estimation of the junction temperature compared with the traditional Cauer model and the improved Cauer model, but also monitored the horizontal temperature differences in the chip layer precisely.

7.
Acta Odontol Latinoam ; 37(1): 3-12, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38920121

RESUMO

Identifying the presence, size, type and location of voids in an endodontic obturation is of great clinical importance because it enables evaluation of the three-dimensionality of the sealing techniques, which can be related to the success of the endodontic treatment. AIM: To analyze by micro-CT the presence of voids in lower single-rooted premolar root canal obturations prepared using the single cone and ultrasound vibration technique. MATERIALS AND METHODS: Twenty extracted single-rooted lower premolars were selected, and the root canal prepared surgically and chemically. In GROUP 1 - Without Vibration, the canal was obturated with a single cone and bioceramic, without applying vibration. In GROUP 2 - With Vibration, the gutta-percha cone inside the root canal was held with a cotton plier to which ultrasound vibration was applied for 3 periods of 3 seconds each. A micro-CT scanner was used to acquire and reconstruct images for analysis. RESULTS: No significant difference was found between obturation techniques, though there were differences between thirds, with the cervical third having a higher percentage of voids than the middle and apical thirds. CONCLUSIONS: The results suggest that the volume of closed, open and total voids does not differ between treatments with and without ultrasound vibration. In the cervical third, the highest volume of voids was related to oval geometry in the teeth evaluated.


La presencia de vacíos en la obturación endodóntica, su tamaño y el tipo y localización tiene gran importancia clínica ya que permite evaluar la tridimensionalidad de las técnicas de sellado y relacionarlas con el éxito del tratamiento endodóntico. OBJETIVO: analizar mediante microtomografía la presencia de vacíos en la obturación del conducto radicular de premolares inferiores unirradiculares, utilizando la técnica de cono único y vibración con ultrasonido. MATERIALES Y MÉTODOS: se seleccionaron 20 premolares inferiores unirradiculares a los que se les realizó la preparación quirúrgica y química del conducto radicular. Se realizó la obturación con cono único y biocerámico GRUPO 1- sin vibración. En el GRUPO 2 - con vibración se aplicó vibración por ultrasonido, se tomó del cono de gutapercha colocado en el interior del conducto con pinza de algodón que fue vibrada durante 3 períodos de 3 segundos cada uno. Las mismas fueron adquiridas y reconstruidas en un microtomógrafo para posterior análisis de las imágenes obtenidas. RESULTADOS: No se evidenciaron diferencias significativas entre ambas técnicas de obturación comparadas, pero si entre los tercios analizados, siendo el cervical el que mayor porcentaje de vacíos presenta en comparación a los cortes correspondientes al tercio medio y apical. CONCLUSIONES: Los resultados sugieren que el volumen de vacíos cerrados, abiertos y total no varía en los tratamientos donde se aplica vibración por ultrasonido. En el tercio cervical, el mayor volumen de vacíos se relaciona con la geometría oval que presentaron las piezas dentarias evaluadas en este estudio.


Assuntos
Obturação do Canal Radicular , Microtomografia por Raio-X , Obturação do Canal Radicular/métodos , Humanos , Técnicas In Vitro , Dente Pré-Molar/diagnóstico por imagem , Guta-Percha
8.
Micromachines (Basel) ; 15(5)2024 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-38793195

RESUMO

This work investigated material extrusion additive manufacturing (MatEx AM) of specialized fluoroelastomer (FKM) compounds for applications in rubber seals and gaskets. The influence of a commercially available perfluoropolyether (PFPE) plasticizer on the printability of a control FKM rubber compound was studied using a custom-designed ram material extruder, Additive Ram Material Extruder (ARME), for printing fully compounded thermoset elastomers. The plasticizer's effectiveness was assessed based on its ability to address challenges such as high compound viscosity and post-print shrinkage, as well as its impact on interlayer adhesion. The addition of the PFPE plasticizer significantly reduced the FKM compound's viscosity (by 70%) and post-print shrinkage (by 65%). While the addition of the plasticizer decreased the tensile strength of the control compound, specimens printed with the plasticized FKM retained 34% of the tensile strength of compression-molded samples, compared to only 23% for the unplasticized compound. Finally, the feasibility of seals and gaskets manufacturing using both conventional and unconventional additive manufacturing (AM) approaches was explored. A hybrid method combining AM and soft tooling for compression molding emerged as the optimal method for seal and gasket fabrication.

9.
Materials (Basel) ; 17(10)2024 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-38793521

RESUMO

This paper brings a new insight into understanding the influence of macrocapsules in packing systems, which can be useful in designing the inert structure of self-healing concrete. A variety of tubular macrocapsules, in terms of types and sizes, was used to assess the capsules' effect in the packing, together with various aggregate types and fractions. The voids ratios (U) of aggregate mixtures were evaluated experimentally and compared with the prediction via the particle packing model of Dewar. The packing of coarse particles was found to be considerably affected by the presence of macrocapsules, while no capsules' effect on the packing of fine particles was attained. A higher capsule dosage and capsule aspect ratio led to a higher voids ratio. In the formulation of the inert structure, the packing disturbance due to capsules can be minimised by increasing the content of fine aggregates over coarse aggregates. Dewar's model showed a good compatibility with experimental results in the absence of capsules. However, the model needed to be upgraded for the introduction of tubular macrocapsules. Accordingly, the effect of macrocapsules was extensively analysed and a 'U model' for capsules (with some limitations) was finally proposed, offering a high predicting accuracy.

10.
Saudi Dent J ; 36(4): 638-644, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38690396

RESUMO

Objective: To identify the potential factors that induce procedural errors during posterior proximal resin composite restorations placed by dental students. Materials and Methods: This retrospective study evaluated 803 bitewing radiographs of posterior proximal resin composite restorations placed by dental students at Imam Abdulrahman bin Faisal University. Atypical radiographic signs of failure were screened, and different patient-, operator-, and clinical-related factors were recorded. Chi-square test was used to examine the relationship between procedural errors and recorded factors. Stepwise adjusted logistic regression model was performed to identify predictors of procedural errors. Results: The most observed errors were internal gaps at the bonding interface and internal voids. Molars had 0.39 the risk of internal voids (odds ratio [OR] = 0.39; confidence interval [CI] = 0.25-0.60; P = <0.0001), 0.41 the risk of sharp angle (OR = 0.41; CI = 0.24-0.68; P = <0.001), and 0.57 the risk of open contact (OR = 0.57; CI = 0.34-0.97; P = 0.04) compared to premolars. Those who were >40 years of age had 1.79 the risk of overhang compared to younger patients (OR = 1.79; CI = 1.04-3.11; P = <0.04). First molars and premolars had 0.64 the risk of overhang compared to second molars and premolars (OR = 0.64; CI = 0.41-1.00; P = 0.04). Junior students had 1.97 the risk of internal gap compared to their senior counterparts (OR = 1.97; CI = 1.20-3.21; P = 0.008). Mesial restorations had 0.38 the risk of external gap compared to mesio-occluso-distal (MOD) restorations (OR = 0.38; CI = 0.19-0.78; P = 0.003). Restorations with a margin coronal to the cemento-enamel junction (CEJ) had 0.44 the risk of external gap compared to those restorations with a margin apical to the CEJ (OR = 0.44; CI = 0.29-0.66; P = <0.0001). Conclusion: Our findings suggested a higher incidence of procedural errors in restoring premolars and MOD cavity preparations. Therefore, it is crucial to enhance the comprehensiveness of laboratory training and expose students to diverse clinical scenarios and various techniques.

11.
Small ; 20(38): e2402935, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38809078

RESUMO

Antimony selenosulfide (Sb2(S,Se)3) has recently emerged as a promising light-absorbing material, attributed to its tunable photovoltaic properties, low toxicity, and robust environmental stability. However, despite these advantages, the current record efficiency for Sb2(S,Se)3 solar cells significantly lags behind their Shockley-Queisser limit, especially when compared to other well-established chalcogenide-based thin-film solar cells, such as CdTe and Cu(In,Ga)Se2. This underperformance primarily arises from the formation of unfavorable defects, predominately located at deep energy levels, which act as recombination centers, thereby limiting the potential for performance enhancement in Sb2(S,Se)3 solar cells. Specifically, deep-level defects, such as sulfur vacancy (VS), have a lower formation energy, leading to severe non-radiative recombination and compromising device performance. To address this challenge, thioacetamide (TA), a sulfur-containing additive is introduced, into the precursor solution for the hydrothermal deposition of Sb2(S,Se)3. This results indicate that the incorporation of TA helps in passivating deep-level defects such as sulfur vacancies and in suppressing the formation of large voids within the Sb2(S,Se)3 absorber. Consequently, Sb2(S,Se)3 solar cells, with reduced carrier recombination and improved film quality, achieved a power conversion efficiency of 9.04%, with notable improvements in open-circuit voltage and fill factor. This work provides deeper insights into the passivation of deep-level donor-like VS defects through the incorporation of a sulfur-containing additive, highlighting pathways to enhance the photovoltaic performance of Sb2(S,Se)3 solar cells.

12.
Entropy (Basel) ; 26(4)2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38667876

RESUMO

We present a novel approach to characterize and quantify microheterogeneity and microphase separation in computer simulations of complex liquid mixtures. Our post-processing method is based on local density fluctuations of the different constituents in sampling spheres of varying size. It can be easily applied to both molecular dynamics (MD) and Monte Carlo (MC) simulations, including periodic boundary conditions. Multidimensional correlation of the density distributions yields a clear picture of the domain formation due to the subtle balance of different interactions. We apply our approach to the example of force field molecular dynamics simulations of imidazolium-based ionic liquids with different side chain lengths at different temperatures, namely 1-ethyl-3-methylimidazolium chloride, 1-hexyl-3-methylimidazolium chloride, and 1-decyl-3-methylimidazolium chloride, which are known to form distinct liquid domains. We put the results into the context of existing microheterogeneity analyses and demonstrate the advantages and sensitivity of our novel method. Furthermore, we show how to estimate the configuration entropy from our analysis, and we investigate voids in the system. The analysis has been implemented into our program package TRAVIS and is thus available as free software.

13.
SA J Radiol ; 28(1): 2778, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38628267

RESUMO

This report presents an extremely rare case of papillary meningioma with prominent flow voids and increased perfusion parameters on MRI in a 28-year-old male presenting with headache. This knowledge helped the neurosurgeon to minimise intra-operative blood loss and achieve a favourable post-surgical outcome. Contribution: A rare case of papillary meningioma and its differentiating features from typical meningiomas have been discussed considering its implications for management as well as prognostication to reduce morbidity and mortality.

14.
Heliyon ; 10(7): e28689, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38596138

RESUMO

This study introduces a post-treatment process, the subpressure-driven soft deformation method, to reduce inherent voids in Material Extrusion (MEX) components. By subjecting printed green components to heat treatment under subpressure, the process enhances viscosity, effectively filling voids formed between deposited tracks. The average porosities of the samples sintered from the green components without and with soft deformation are calculated to be 3.55% and 2.36%, respectively. A comparison of the tensile strengths and fracture surfaces of the sintered samples with and without soft deformation treatment indicated that the sintered samples with soft deformation treatment exhibited narrower standard deviation for the various mechanical properties. Capillary rheometer calculations indicate feedstock viscosity to be between 450.34 and 1018.31 Pa s under subpressure, diminishing inter-track voids without sizeable dimensional changes. Molecular dynamics simulation demonstrates a 3.7-fold increase in bond strength, indicating intertrack voids effectively eliminated. Reduced inter-particle distances facilitate necking, grain growth, and improved sintered density.

15.
J Microsc ; 294(2): 191-202, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38450781

RESUMO

The Ambassador Bridge between Detroit, Michigan, and Windsor, Ontario, has served for almost 100 years as North America's busiest international border crossing. But in 2025, the Ambassador will be replaced by the new Gordie Howe International Bridge. The Gordie Howe is a cable-stayed bridge, with two massive 220 m tall concrete piers on opposite banks of the St. Claire River, a single clear span of 853 m, and 42 m of clearance over this busy waterway. To ensure durability in this harsh freeze-thaw environment, air-entrained concrete is specified throughout. And, to ensure the quality of air entrainment, the ASTM C 457 Procedure C, Contrast Enhanced Method is employed. While a similar automated microscopic approach has been in use for well over a decade according to EN 480-11 Determination of air void characteristics in hardened concrete, this is the first large-scale application of automated air void assessment in North American infrastructure. According to the ASTM Procedure C, the air void characteristics are determined through digital image processing, while the paste content may be determined by either mix design parameters, manual point count, or 'other means'. Of these three options, point counting is used for Gordie Howe; but in parallel, during each point count, the digital image coordinates and phase identifications for each evaluated stop are recorded. This allows for training of a neural network, for automated determination of paste content, as demonstrated here.

16.
Odontology ; 112(3): 839-846, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38244154

RESUMO

The aim of the study was to evaluate the ability of a modified passive deflation needle to reduce the apical voids during the intra-canal iRoot SP sealer injection. A modified passive deflation injection needle was designed. Forty 20°-curved and twenty S-shaped single-canal resin block models were allocated into six groups. Each group was mechanically prepared to #25/04 or #25/06 file; then the root canals were injected with iRoot SP sealer using a modified needle or a normal plastic needle. Radiographs were taken to measure the length of apical void in each specimen. Similarly, twenty single-canal extracted premolars were collected and randomly divided into four groups. Each group was prepared to #25/04 or #25/06 file; then the root canals were injected with iRoot SP sealer using a modified needle or a normal plastic needle. Roots were then scanned using micro-computed tomography (micro-CT), and the volume of voids in root canals was analyzed and compared among groups. Statistical analysis demonstrated that the length and the volumetric percentage of voids were much lower in the modified needle group in both resin block root canal models and extract teeth than the normal plastic needle group (P < 0.05). The modified passive deflation needle can efficiently reduce apical voids during the intra-canal iRoot SP sealer injection.


Assuntos
Dente Pré-Molar , Agulhas , Materiais Restauradores do Canal Radicular , Microtomografia por Raio-X , Materiais Restauradores do Canal Radicular/química , Humanos , Técnicas In Vitro , Desenho de Equipamento , Cavidade Pulpar , Injeções , Preparo de Canal Radicular/instrumentação , Preparo de Canal Radicular/métodos , Ápice Dentário , Obturação do Canal Radicular/métodos
17.
Acta odontol. latinoam ; 37(1): 3-12, Jan. 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1563654

RESUMO

ABSTRACT Identifying the presence, size, type and location of voids in an endodontic obturation is of great clinical importance because it enables evaluation of the three-dimensionality of the sealing techniques, which can be related to the success of the endodontic treatment. Aim To analyze by micro-CT the presence of voids in lower single-rooted premolar root canal obturations prepared using the single cone and ultrasound vibration technique. Materials and methods Twenty extracted single-rooted lower premolars were selected, and the root canal prepared surgically and chemically. In GROUP 1 - Without Vibration, the canal was obturated with a single cone and bioceramic, without applying vibration. In GROUP 2 - With Vibration, the gutta-percha cone inside the root canal was held with a cotton plier to which ultrasound vibration was applied for 3 periods of 3 seconds each. A micro-CT scanner was used to acquire and reconstruct images for analysis. Results No significant difference was found between obturation techniques, though there were differences between thirds, with the cervical third having a higher percentage of voids than the middle and apical thirds. Conclusions The results suggest that the volume of closed, open and total voids does not differ between treatments with and without ultrasound vibration. In the cervical third, the highest volume of voids was related to oval geometry in the teeth evaluated.


RESUMEN La presencia de vacíos en la obturación endodóntica, su tamaño y el tipo y localización tiene gran importancia clínica ya que permite evaluar la tridimensionalidad de las técnicas de sellado y relacionarlas con el éxito del tratamiento endodóntico. Objetivo analizar mediante microtomografía la presencia de vacíos en la obturación del conducto radicular de premolares inferiores unirradiculares, utilizando la técnica de cono único y vibración con ultrasonido. Materiales y Método se seleccionaron 20 premolares inferiores unirradiculares a los que se les realizó la preparación quirúrgica y química del conducto radicular. Se realizó la obturación con cono único y biocerámico GRUPO 1- sin vibración. En el GRUPO 2 - con vibración se aplicó vibración por ultrasonido, se tomó del cono de gutapercha colocado en el interior del conducto con pinza de algodón que fue vibrada durante 3 períodos de 3 segundos cada uno. Las mismas fueron adquiridas y reconstruidas en un microtomógrafo para posterior análisis de las imágenes obtenidas. Resultados No se evidenciaron diferencias significativas entre ambas técnicas de obturación comparadas, pero si entre los tercios analizados, siendo el cervical el que mayor porcentaje de vacíos presenta en comparación a los cortes correspondientes al tercio medio y apical. Conclusiones Los resultados sugieren que el volumen de vacíos cerrados, abiertos y total no varía en los tratamientos donde se aplica vibración por ultrasonido. En el tercio cervical, el mayor volumen de vacíos se relaciona con la geometría oval que presentaron las piezas dentarias evaluadas en este estudio.

18.
Odontology ; 112(2): 546-551, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37803215

RESUMO

This study evaluated the feasibility of an automated method to delimit the required area to quantitatively analyze root filling voids and gaps from cross-sectional confocal laser scanning microscopy (CLSM) images. Root canals of maxillary canines were prepared with rotary instruments and filled by lateral compaction technique using gutta-percha and AH Plus sealer. The roots were stored (100% humidity, 37 °C) for a period of 24 h and then transversally sectioned to obtain 2-mm-thick slices from the apical and middle thirds. The areas corresponding to filling materials, gaps, and voids were manually delimited or automatically demarked by ImageJ software after converting the images to the RGB color system. Based on manual and automatic delimitations, the percentages of voids and gaps were calculated. Data of voids and gaps between middle and apical thirds were individually compared by paired t-test. Pearson`s correlation test was used to assess the correlation of data between the methods. Irrespective of the method of area delimitation, no difference was observed between the root thirds for both voids and gaps, while the p-values calculated for each method were similar. Almost perfect correlations between the methods were observed for both outcomes. The proposed method to automatically delimit the areas corresponding to filling material, voids, and gaps appears to be a valid method to facilitate the quantitative analysis of defects in root canal fillings using topographic CSLM images.


Assuntos
Materiais Restauradores do Canal Radicular , Resinas Epóxi , Estudos Transversais , Preparo de Canal Radicular , Cavidade Pulpar/diagnóstico por imagem , Teste de Materiais , Guta-Percha , Obturação do Canal Radicular/métodos
19.
Rev. Fac. Odontol. (B.Aires) ; 39(91): 41-48, 2024. ilus
Artigo em Espanhol | LILACS | ID: biblio-1554951

RESUMO

La microtomografía es un estudio que utiliza la ra-diación X para obtener imágenes de tamaños de mi-lésimas de milímetros y de alta resolución. Las imá-genes 2D son procesadas por diferentes softwares para lograr obtener volúmenes capaces de ser ana-lizados tridimensionalmente. La microtomografía es el estudio de elección a la hora de evaluar caracte-rísticas muy pequeñas con gran precisión. La obtu-ración endodóntica buscar lograr un sellado que no tenga espacios vacíos dentro de la masa de obtura-ción. Esto es importante debido a que los poros pue-den permitir, si están en contacto con la pared den-tinaria, la entrada de microorganismos al conducto radicular. El objetivo de este trabajo fue describir el procedimiento para el análisis y visualización de los espacios vacíos dentro de la obturación endodónti-ca, utilizando la microtomografía de rayos x, y esta-blecer un protocolo para ser utilizado por cualquier investigador(AU)


Microtomography is a study that uses X-radiation to obtain high-resolution images of sizes of thousandths of millimeters. The 2D images are processed by different software to obtain volumes capable of being analyzed three-dimensionally. Microtomography is the study of choice when evaluating very small features with great precision. Endodontic filling seeks to achieve a seal that does not have voids within the filling obturation. This is important because the voids can allow, if they are in contact with the dentin wall, the entry of microorganisms into the root canal. The objective of this work was to describe the procedure for the analysis and visualization of voids within the endodontic filling using microtomography and to establish the protocol to be used by any researcher (AU)


Assuntos
Obturação do Canal Radicular/efeitos adversos , Protocolos Clínicos , Microtomografia por Raio-X/métodos , Porosidade , Imageamento Tridimensional/métodos , Infiltração Dentária/prevenção & controle
20.
Sensors (Basel) ; 23(24)2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38139593

RESUMO

Optimization of the structure of piezoelectric transducers such as the proper design of matching layers can increase maximum wave energy transmission to the host structure and transducer sensitivity. A novel configuration of an ultrasonic transducer, where elastic metamaterial insertion is introduced to provide bulk wave mode conversion and to increase wave energy transfer into a substrate, is proposed. Configurations of layered elastic metamaterials with crack-like voids are examined theoretically since they can provide wide band gaps and strong wave localization and trapping. The analysis shows that the proposed metamaterial-based matching layers can sufficiently change wave energy transmission from a piezoelectric active element for various frequency ranges (relatively low frequencies as well as higher ones). The proposed configuration can also be useful for advanced sensing with higher sensitivity in certain frequency ranges or for demultiplexing different kinds of elastic waves.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA