Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Anal Chem ; 89(9): 4907-4913, 2017 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-28375002

RESUMO

The National Institute of Standards and Technology (NIST) has developed Standard Reference Material (SRM) 972a Vitamin D Metabolites in Frozen Human Serum as a replacement for SRM 972, which is no longer available. SRM 972a was developed in collaboration with the National Institutes of Health's Office of Dietary Supplements. In contrast to the previous reference material, three of the four levels of SRM 972a are composed of unmodified human serum. This SRM has certified and reference values for the following 25-hydroxyvitamin D [25(OH)D] species: 25(OH)D2, 25(OH)D3, and 3-epi-25(OH)D3. The value assignment and certification process included three isotope-dilution mass spectrometry approaches, with measurements performed at NIST and at the Centers for Disease Control and Prevention (CDC). The value assignment methods employed have been modified from those utilized for the previous SRM, and all three approaches now incorporate chromatographic resolution of the stereoisomers, 25(OH)D3 and 3-epi-25(OH)D3.


Assuntos
25-Hidroxivitamina D 2/sangue , Calcifediol/sangue , Cromatografia Líquida/normas , Espectrometria de Massas/normas , 25-Hidroxivitamina D 2/normas , Calcifediol/química , Calcifediol/normas , Humanos , Padrões de Referência , Valores de Referência , Estereoisomerismo , Estados Unidos , United States Government Agencies
2.
Bioanalysis ; 7(2): 167-78, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25587834

RESUMO

OBJECTIVE: We developed and validated an analytical method for quantifying 25-hydroxyvitamin D2 (25OHD2) and 25-hydroxyvitamin D3 (25OHD3) in serum and plasma. METHODS: Samples, pretreated with zinc sulfate and methanol, were extracted with hexane. Separation was achieved via UHPLC and 25OHD quantification was accomplished by a triple quadrupole mass spectrometer. RESULTS: Imprecision was 3.6-15.1%CV and bias 88.0-126.0%. Extraction efficiency was 76.5-110.5%, whereas the matrix effect ranged from -46.7 to -32.0%. The method was applied to authentic specimens. The results showed no significant difference between serum and plasma; strong correlation with paired values from an external laboratory; and analyte stability for 15 days. CONCLUSION: This method provides reliable and accurate measurement of 25OHD for use in clinical practice.


Assuntos
25-Hidroxivitamina D 2/sangue , Análise Química do Sangue/métodos , Calcifediol/sangue , 25-Hidroxivitamina D 2/normas , Animais , Calcifediol/normas , Bovinos , Cromatografia Líquida de Alta Pressão/normas , Humanos , Controle de Qualidade , Soroalbumina Bovina/química , Espectrometria de Massas em Tandem/normas
3.
J Nutr ; 140(11): 2030S-45S, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20881084

RESUMO

A roundtable to discuss monitoring of serum 25-hydroxyvitamin D [25(OH)D] in the NHANES was held in late July 2009. Topics included the following: 1) options for dealing with assay fluctuations in serum 25(OH)D in the NHANES conducted between 1988 and 2006; 2) approaches for transitioning between the RIA used in the NHANES between 1988 and 2006 to the liquid chromatography tandem MS (LC-MS/MS) measurement procedure to be used in NHANES 2007 and later; 3) approaches for integrating the recently available standard reference material for vitamin D in human serum (SRM 972) from the National Institute of Standards and Technology (NIST) into the NHANES; 4) questions regarding whether the C-3 epimer of 25-hydroxyvitamin D3 [3-epi-25(OH)D3] should be measured in NHANES 2007 and later; and 5) identification of research and educational needs. The roundtable experts agreed that the NHANES data needed to be adjusted to control for assay fluctuations and offered several options for addressing this issue. The experts suggested that the LC-MS/MS measurement procedure developed by NIST could serve as a higher order reference measurement procedure. They noted the need for a commutability study for the recently released NIST SRM 972 across a range of measurement procedures. They suggested that federal agencies and professional organizations work with manufacturers to improve the quality and comparability of measurement procedures across all laboratories. The experts noted the preliminary nature of the evidence of the 3-epi-25(OH)D3 but felt that it should be measured in 2007 NHANES and later.


Assuntos
25-Hidroxivitamina D 2/sangue , Calcifediol/sangue , Inquéritos Nutricionais , 25-Hidroxivitamina D 2/análogos & derivados , 25-Hidroxivitamina D 2/química , 25-Hidroxivitamina D 2/normas , Calcifediol/química , Calcifediol/normas , Cromatografia Líquida de Alta Pressão , Humanos , Padrões de Referência , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA