Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 589
Filtrar
1.
Vestn Oftalmol ; 140(2): 48-53, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38742498

RESUMO

Purpose. The study investigates corneal and higher-order internal aberrations in patients with amblyopia of different etiologies and their relationship with visual acuity, refraction, axial length, and fixation parameters. MATERIAL AND METHODS: Forty-five patients (90 eyes) were examined. All patients were divided into five groups: 1 - with dysbinocular amblyopia; 2 - with refractive amblyopia; 3 - with anisometropic amblyopia; 4 - with relative amblyopia due to congenital myopia; 5 (control) - fellow eyes without amblyopia. Aberrometry was performed using the OPD-Scan III device (Nidek, Japan). Fixation parameters were studied on the MP-3 microperimeter (Nidek, Japan). Correlation analysis was performed using Pearson's linear correlation coefficient (r). RESULTS: In amblyopia associated with congenital myopia, a significant increase in corneal and internal aberrations RMS, Total HOA, astigmatism (V) (0.65±0.26; 1.01±0.31; 4.22±1.17; -2.17±0.72; 0.86±0.3, respectively; control group - 0.44±0.19; 0.58±0.27; 1.0±0.75; -0.94±0.89; 0.47±0.65) and internal spherical aberration (0.06±0.02; control group - 0.04±0.03) was found. In dysbinocular amblyopia, a significant increase in internal aberrations Trefoil (V) and Coma (H) (0.75±0.52 and 0.17±0.35, respectively; control group - 0.05±0.28 and -0.07±0.21) was found, which correlated with a decrease in fixation density in the 2° ring (r= -0.40, r= -0.41). CONCLUSIONS: The increased level of higher-order aberrations in amblyopia associated with congenital myopia is due to the anatomical and optical features of the eyes. The increase in internal aberrations Trefoil (V) and Coma (H) in dysbinocular amblyopia is associated with a mismatch of the optical elements of the eye due to impaired fixation, i.e., it is not the cause, but the consequence of amblyopia.


Assuntos
Ambliopia , Miopia , Acuidade Visual , Humanos , Ambliopia/etiologia , Ambliopia/fisiopatologia , Ambliopia/diagnóstico , Masculino , Criança , Feminino , Miopia/complicações , Miopia/fisiopatologia , Miopia/diagnóstico , Refração Ocular/fisiologia , Aberrometria/métodos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/etiologia , Aberrações de Frente de Onda da Córnea/diagnóstico
3.
J Refract Surg ; 40(5): e291-e303, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38717083

RESUMO

PURPOSE: To compare differences in corneal densitometry (CD) and higher order aberrations (HOAs) in eyes that underwent small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for the treatment of myopia and myopic astigmatism at postoperative months 3, 6, and 12, and to evaluate their changes in a separate cohort of eyes after SMILE enhancement. METHODS: In this prospective, randomized, paired-eye clinical trial, consecutive eligible participants were randomized to undergo SMILE or FS-LASIK in either eye. Main outcome measures were CD and HOAs preoperatively and at 3, 6, and 12 months postoperatively. A separate cohort of consecutive patients who had SMILE and underwent enhancement were also included for comparison. RESULTS: For CD, no significant differences were found between SMILE and FS-LASIK up to month 12. For HOA measured by wavefront aberrometry, both SMILE and FS-LASIK had an increase in total root mean square (RMS) HOAs, spherical aberration (SA), and vertical coma up to month 12. SMILE had an additional increase in vertical quatrefoil, and FS-LASIK had an increase in horizontal coma at month 12. FS-LASIK had higher SA than SMILE, whereas SMILE had higher vertical quatrefoil than FS-LASIK at month 12. Central and posterior zone CD had significantly decreased after SMILE enhancement compared to after primary SMILE up to 2 years after enhancement. RMS HOAs, lower order aberrations, and SA were all increased after SMILE enhancement compared to after primary SMILE. CONCLUSIONS: SMILE induced lower SA but higher vertical quatrefoil than FS-LASIK at 1 year. Both SMILE and FS-LASIK had similar increases in RMS HOAs and vertical coma up to 1 year. There were no differences in CD between both groups. SMILE enhancement additionally had decreased central and posterior CD but greater RMS HOAs and SA compared to primary SMILE. [J Refract Surg. 2024;40(5):e291-e303.].


Assuntos
Aberrometria , Astigmatismo , Córnea , Substância Própria , Aberrações de Frente de Onda da Córnea , Densitometria , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Miopia , Refração Ocular , Acuidade Visual , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Estudos Prospectivos , Miopia/cirurgia , Miopia/fisiopatologia , Adulto , Feminino , Masculino , Lasers de Excimer/uso terapêutico , Acuidade Visual/fisiologia , Substância Própria/cirurgia , Córnea/cirurgia , Córnea/fisiopatologia , Adulto Jovem , Refração Ocular/fisiologia , Astigmatismo/cirurgia , Astigmatismo/fisiopatologia , Cirurgia da Córnea a Laser/métodos , Topografia da Córnea
4.
J Refract Surg ; 40(5): e321-e327, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38717082

RESUMO

PURPOSE: To evaluate the characteristic of corrective epithelial thickness after femtosecond laser-assisted lenticule intrastromal keratoplasty (LIKE) to correct moderate-to-high hyperopia. METHODS: The prospective case series study of the LIKE procedure was performed to correct moderate-to-high hyperopia. The epithelial thickness map was generated by anterior segment optical coherence tomography (AS-OCT) in the corneal central 9-mm zone. Keratometry and corneal higher order aberrations were analyzed by Pentacam (Oculus Optikgeräte GmbH) preoperatively and postoperatively. RESULTS: In the 26 eyes of 13 participants who underwent the LIKE procedure for moderate-to-high hyperopia, the attempted spherical equivalence (SEQ) was +6.50 ± 1.09 diopters (D). Compared to the preoperative epithelial thickness maps, the postoperative epithelial thickness had become significantly thinner in the central 5-mm zone; the difference was 6 to 7 µm. The paracentral epithelium performed nonuniform remodeling; the thinnest epithelial thickness was located in the inferotemporal section, which has the greatest difference from the superonasal; the difference between these two was approximately 3 µm. Through correlation analysis, it was found that the sections with thinner epithelium were significantly related to corneal curvature and corneal vertical coma. CONCLUSIONS: The LIKE procedure can be used to correct moderate-to-high hyperopia. This study further indicated the epithelial remodeling characteristic after the LIKE procedure: the central and paracentral corneal epithelial thickness becomes thinner, and the epithelial thickness distributes non-uniformly, which may be the important factor of the postoperative curvature asymmetric distribution and induction of corneal vertical coma. [J Refract Surg. 2024;40(5):e321-e327.].


Assuntos
Substância Própria , Topografia da Córnea , Epitélio Corneano , Hiperopia , Refração Ocular , Tomografia de Coerência Óptica , Acuidade Visual , Humanos , Hiperopia/cirurgia , Hiperopia/fisiopatologia , Estudos Prospectivos , Substância Própria/cirurgia , Substância Própria/patologia , Masculino , Feminino , Adulto , Acuidade Visual/fisiologia , Epitélio Corneano/cirurgia , Epitélio Corneano/patologia , Refração Ocular/fisiologia , Pessoa de Meia-Idade , Lasers de Excimer/uso terapêutico , Adulto Jovem , Aberrações de Frente de Onda da Córnea/fisiopatologia , Cirurgia da Córnea a Laser/métodos , Oftalmopatias Hereditárias
5.
BMC Ophthalmol ; 24(1): 211, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38741093

RESUMO

OBJECTIVE: To investigate the correlation between higher-order aberrations (HOA) after small incision lenticule extraction (SMILE) and the severity of myopia and astigmatism, along with the relevant factors. These findings will provide valuable insights for decreasing the occurrence of HOA after SMILE and enhancing visual quality. METHODS: A total of 75 patients (150 eyes) with myopia and astigmatism who underwent SMILE were categorized into four groups based on the severity of myopia and astigmatism: Myopia Group 1 (Group M1, spherical diopter ranged from -1.00 D to -4.00 D), Myopia Group 2 (Group M2, spherical diopter ranged from -4.10 D to -10.00 D), Astigmatism Group 1 (Group A1, cylindrical diopter ranged from 0 D to -1.00 D), and Astigmatism Group 2 (Group A2, cylindrical diopter ranged from -1.10 D to -3.00 D). A comprehensive assessment was performed to examine the association between HOA and various relevant factors, including a detailed analysis of the subgroups. RESULTS: Group M1 had significantly lower levels of total eye coma aberration (CA), corneal total HOA (tHOA), internal tHOA, and vertical CA ( Z 3 - 1 ) after SMILE than Group M2 (P < 0.05). Similarly, Group A1 had significantly lower levels of total eye tHOA, CA, trefoil aberration (TA), corneal tHOA, TA, and vertical TA ( Z 3 - 3 ) after SMILE than Group A2 (P < 0.05). Pearson correlation analysis indicated a statistically significant positive relationship between the severity of myopia/astigmatism and most HOA (P < 0.05). Subgroup evaluations demonstrated a notable increase in postoperative HOA associated with myopia and astigmatism in Groups M2 and A2 compared with the control group. Lenticule thickness, postoperative central corneal thickness (CCT), postoperative uncorrected distance visual acuity (UDVA), and postoperative corneal Km and Cyl were strongly correlated with most HOA. Age, eyes, and postoperative intraocular pressure (IOP) were only associated with specific HOA. CONCLUSION: HOA positively correlated with the severity of myopia and astigmatism after SMILE. However, this relationship was not linear. HOA after SMILE was influenced by various factors, and additional specialized investigations are required to establish its clinical importance.


Assuntos
Astigmatismo , Cirurgia da Córnea a Laser , Aberrações de Frente de Onda da Córnea , Miopia , Refração Ocular , Acuidade Visual , Humanos , Miopia/cirurgia , Miopia/fisiopatologia , Astigmatismo/fisiopatologia , Astigmatismo/etiologia , Masculino , Feminino , Adulto , Acuidade Visual/fisiologia , Cirurgia da Córnea a Laser/métodos , Cirurgia da Córnea a Laser/efeitos adversos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/etiologia , Adulto Jovem , Refração Ocular/fisiologia , Substância Própria/cirurgia , Estudos Retrospectivos , Lasers de Excimer/uso terapêutico , Complicações Pós-Operatórias , Topografia da Córnea , Adolescente
7.
Indian J Ophthalmol ; 72(5): 712-717, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38648433

RESUMO

PURPOSE: To compare the changes encountered in corneal biomechanics and aberration profile following accelerated corneal collagen cross-linking (CXL) using hypo-osmolar and iso-osmolar riboflavin in corneal thicknesses of <400 and >400 microns, respectively. METHODS: This is a prospective, interventional, comparative study involving 100 eyes of 75 patients with progressive keratoconus. Eyes were divided into two groups based on corneal thickness: group 1 included eyes with a corneal thickness of <400 microns who underwent hypo-osmolar CXL, and group 2 included eyes with a corneal thickness of >400 microns who underwent iso-osmolar CXL. Corneal biomechanical and aberration profiles were evaluated and compared between groups. RESULTS: In group 1, all higher-order aberrations (HOA) except secondary astigmatism significantly decreased from baseline; however, in group 2, only coma and trefoil decreased. The corneal resistance factor and corneal hysteresis significantly improved in both groups, which was significantly greater in group 2 than in group 1. The change in inverse radius, deformation amplitude, and tomographic biomechanical index was significantly improved in group 2 as compared to group 1. CONCLUSION: Improvement in corrected distance visual acuity and decrease in HOA were significantly better in the hypo-osmolar CXL group; however, the improvement in biomechanical strength of the cornea was significantly better in the iso-osmolar group.


Assuntos
Colágeno , Córnea , Topografia da Córnea , Reagentes de Ligações Cruzadas , Ceratocone , Fármacos Fotossensibilizantes , Riboflavina , Raios Ultravioleta , Acuidade Visual , Adolescente , Adulto , Feminino , Humanos , Masculino , Adulto Jovem , Fenômenos Biomecânicos , Colágeno/metabolismo , Córnea/diagnóstico por imagem , Córnea/fisiopatologia , Córnea/efeitos dos fármacos , Substância Própria/metabolismo , Substância Própria/efeitos dos fármacos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Reagentes de Ligações Cruzadas/uso terapêutico , Seguimentos , Ceratocone/tratamento farmacológico , Ceratocone/fisiopatologia , Ceratocone/diagnóstico , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Estudos Prospectivos , Refração Ocular/fisiologia , Riboflavina/uso terapêutico , Acuidade Visual/fisiologia , Criança
8.
Cont Lens Anterior Eye ; 47(3): 102133, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38467534

RESUMO

BACKGROUND: To assess accommodation and spherical aberration changes during one year of orthokeratology lens wear and one month after lens cessation. METHODS: A prospective, randomized, longitudinal study was conducted on forty-seven young healthy subjects at the Optometry Clinic of the Complutense University of Madrid (Spain). Non-cycloplegic refraction, high and low uncorrected visual acuity, high and low best corrected visual acuity, accommodative lag, horizontal near phoria, corneal topography, and high-order aberrations were performed at baseline, 1-day, 1-week, 1-, 6- and 12-months of lens wear and after one month of wash out period. p < 0.05 was considered as statistically significant. RESULTS: Spherical equivalent refraction (SE) was -3.23 ± 1.57D at baseline and -0.36 ± 0.64D after 12-months of lens wear, while accommodative lag changed from 0.53 ± 0.39D to 0.15 ± 0.29D after one year of lens wear. No significant differences were found when comparing SE at baseline and after one month of lens cessation (p > 0.05). A high correlation was found between the accommodative lag at baseline and after 12 M of lens wear. 22 out of 25 subjects with exophoria at baseline showed a significant reduction in the deviation at 12-months (p < 0.05). Total spherical aberration increased during all visits due to the lens wear (p < 0.05) although internal spherical aberration showed a significant decrease for 1-week, 1-month and 12-month visits (p < 0,05). CONCLUSION: Orthokeratology lenses may change the accommodative response of the patient as a reduction on accommodative lag on exophoric patients and an overall increase on the internal spherical aberrations was found during treatment but return to nearly baseline values when cessation.


Assuntos
Acomodação Ocular , Aberrações de Frente de Onda da Córnea , Procedimentos Ortoceratológicos , Refração Ocular , Acuidade Visual , Humanos , Masculino , Feminino , Acomodação Ocular/fisiologia , Estudos Prospectivos , Refração Ocular/fisiologia , Acuidade Visual/fisiologia , Adulto Jovem , Aberrações de Frente de Onda da Córnea/fisiopatologia , Topografia da Córnea , Adulto , Miopia/terapia , Miopia/fisiopatologia , Seguimentos , Adolescente , Lentes de Contato
9.
Ophthalmic Physiol Opt ; 44(4): 746-756, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38389207

RESUMO

PURPOSE: The goal was to use SyntEyes modelling to estimate the allowable alignment error of wavefront-guided rigid contact lens corrections for a range of normal and keratoconic eye aberration structures to keep objectively measured visual image quality at or above average levels of well-corrected normal eyes. Secondary purposes included determining the required radial order of correction, whether increased radial order of the corrections further constrained the allowable alignment error and how alignment constraints vary with keratoconus severity. METHODS: Building on previous work, 20 normal SyntEyes and 20 keratoconic SyntEyes were fitted with optimised wavefront-guided rigid contact lens corrections targeting between three and eight radial orders that drove visual image quality, as measured objectively by the visual Strehl ratio, to near 1 (best possible) over a 5-mm pupil for the aligned position. The resulting wavefront-guided contact lens was then allowed to translate up to ±1 mm in the x- and y-directions and rotate up ±15°. RESULTS: Allowable alignment error changed as a function of the magnitude of aberration structure to be corrected, which depends on keratoconus severity. This alignment error varied only slightly with the radial order of correction above the fourth radial order. To return the keratoconic SyntEyes to average levels of visual image quality depended on maximum anterior corneal curvature (Kmax). Acceptable tolerances for misalignment that returned keratoconic visual image quality to average normal levels varied between 0.29 and 0.63 mm for translation and approximately ±6.5° for rotation, depending on the magnitude of the aberration structure being corrected. CONCLUSIONS: Allowable alignment errors vary as a function of the aberration structure being corrected, the desired goal for visual image quality and as a function of keratoconus severity.


Assuntos
Lentes de Contato , Topografia da Córnea , Ceratocone , Acuidade Visual , Humanos , Ceratocone/fisiopatologia , Ceratocone/diagnóstico , Topografia da Córnea/métodos , Adulto , Feminino , Masculino , Acuidade Visual/fisiologia , Adulto Jovem , Aberrações de Frente de Onda da Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/diagnóstico , Refração Ocular/fisiologia , Córnea/diagnóstico por imagem , Córnea/fisiopatologia
10.
Invest Ophthalmol Vis Sci ; 63(2): 22, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-35147660

RESUMO

Purpose: To investigate the impact of the size and location of waterclefts (WC), which are one of several cataract subtypes, on visual function by optical simulation analysis. Methods: An optical simulation software (CODE V) was used to develop a schematic eye model and several sizes of WC central and peripheral types that were located below the anterior and posterior subcapsules of the crystalline lens, and analyses of refraction, higher-order aberrations (HOA), and the modulation transfer function (MTF) were performed. Results: An increase in the WC size increased the refraction and HOA and decreased the MTF. The impact of the WC below the posterior subcapsule on the visual function was more enhanced than that below the anterior subcapsule. Large WC demonstrated a remarkable hyperopic shift in refractive power as well as an increase in HOA. The MTF decreased slightly with increasing WC size at a spatial frequency of 20 cycles/mm, and it decreased remarkably at 60 cycles/mm. Conclusions: The impact on the visual function increased with increasing WC size. It was revealed that eyes with WC below the posterior subcapsule are more hyperopic than those with WC below the anterior subcapsule, and the former have a higher HOA and lower MTF than the latter.


Assuntos
Catarata/fisiopatologia , Simulação por Computador , Erros de Refração/fisiopatologia , Acuidade Visual/fisiologia , Idoso , Catarata/diagnóstico por imagem , Aberrações de Frente de Onda da Córnea/fisiopatologia , Feminino , Humanos , Pessoa de Meia-Idade , Refração Ocular/fisiologia
11.
Cornea ; 41(4): 435-442, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34267059

RESUMO

PURPOSE: The purpose of this study was to evaluate the efficacy and safety of implantation of a new continuous corneal ring in keratoconic corneas of an Iranian population. METHODS: This study was conducted on 95 contact lens-intolerant keratoconic eyes with clear central corneas. A continuous corneal ring, annular intrastromal corneal inlay (AICI), was inserted using femtosecond laser in all cases. Patients were followed up for 1, 3, and 12 months postsurgery. Visual and subjective refractive outcomes were evaluated in each examination. Besides, keratometry and aberrometric values were recorded before and 12 months after surgery. Finally, vector analysis of refractive astigmatism was performed using the Alpins method. RESULTS: The uncorrected and corrected distance visual acuities improved significantly 12 months after surgery from 0.91 ± 0.39 to 0.38 ± 0.22 (P < 0 0.001) and 0.33 ± 0.21 to 0.13 ± 0.11 logMAR (P < 0.001), respectively. Moreover, spherical and cylindrical refractive components reduced from -2.52 ± 2.62 to -0.76 ± 1.78 D (P < 0.001) and -4.14 ± 1.64 to -1.91 ± 1.18 D (P < 0.001), respectively. The mean anterior keratometry had a significant reduction 12 months after AICI insertion (P< 0.001). Primary coma and spherical aberration values showed a significant increase (both, P < 0.05). Our results showed 100% safety (safety index: 1.8) and 45% efficacy (efficacy index: 1). CONCLUSIONS: AICI implantation seemed to be a safe and effective procedure for improving visual acuity and refractive outcomes in subjects with keratoconus.


Assuntos
Substância Própria/cirurgia , Ceratocone/cirurgia , Próteses e Implantes , Implantação de Prótese/métodos , Aberrometria , Adulto , Topografia da Córnea , Aberrações de Frente de Onda da Córnea/fisiopatologia , Feminino , Seguimentos , Humanos , Irã (Geográfico) , Ceratocone/fisiopatologia , Masculino , Desenho de Prótese , Refração Ocular/fisiologia , Resultado do Tratamento , Acuidade Visual/fisiologia
12.
Cornea ; 40(4): 449-452, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33881810

RESUMO

PURPOSE: To determine which baseline characteristics are associated with vision-related quality of life (QOL) after endothelial keratoplasty. METHODS: A patient- and outcome-masked randomized clinical trial. Consecutive patients presenting with isolated endothelial disease requiring endothelial keratoplasty at Oregon Health Sciences University and Stanford University. Study eyes randomized to one of the 2 types of endothelial keratoplasty were given the national eye institute vision function questionnaire 25 at baseline and 12 months. In this prespecified secondary outcome, we assessed the role of recipient and donor characteristics as predictors of the 12-month national eye institute vision function questionnaire 25 change score. RESULTS: The mean vision function questionnaire (VFQ) score was 74 (SD 14) at baseline and increased to 82 (SD 12) at 3 months and 87 (SD 10) at 12 months. We were unable to find a difference in vision-related QOL in study participants who underwent Descemet membrane endothelial keratoplasty compared with ultrathin Descemet stripping endothelial keratoplasty [coef -0.98, 95% confidence interval (CI) -9.27 to 7.31; P = 0.82]. In multivariable analysis, patients who underwent endothelial keratoplasty in 2 eyes had approximately 8 points higher VFQ at 12 months after the second eye than those who had only one eye enrolled (95% CI 0.10-15.72; P = 0.047). Posterior densitometry produced an approximately 1-point increase each in the VFQ change score for each 1 grayscale unit increase at baseline (95% CI 0.26-1.81; P = 0.009). Although the sample size was small, a diagnosis of pseudophakic bullous keratopathy had approximately 19-points more improvement on average compared with Fuchs (95% CI 7.68-30.00; P = 0.001). CONCLUSIONS: Bilateral endothelial keratoplasty resulted in higher vision-related QOL compared with unilateral. Baseline densitometry, objective measure of corneal haze that predicts vision-related QOL, may play a role in monitoring disease progression.


Assuntos
Córnea/fisiopatologia , Distrofias Hereditárias da Córnea/cirurgia , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior/métodos , Qualidade de Vida/psicologia , Visão Ocular/fisiologia , Acuidade Visual/fisiologia , Idoso , Distrofias Hereditárias da Córnea/fisiopatologia , Distrofias Hereditárias da Córnea/psicologia , Aberrações de Frente de Onda da Córnea/fisiopatologia , Densitometria , Método Duplo-Cego , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Inquéritos e Questionários , Resultado do Tratamento
13.
J. optom. (Internet) ; 14(1): 78-85, ene.-mar. 2021. ilus, tab, graf
Artigo em Inglês | IBECS | ID: ibc-200295

RESUMO

PURPOSE: to evaluate the effects of kappa angle and intraocular orientation on the theoretical performance of asymmetric multifocal intraocular lenses (MIOL). METHODS: For a total of 21 corneal aberrations, a computational analysis simulated the implantation of a computationally designed MIOL. An image quality parameter (IQ) (visually modulated transfer function metric) was calculated for a 5.0-mm pupil and for three conditions: distance, intermediate, and near vision. The procedure was repeated for each eye after a rotation of the MIOL with respect to the cornea from 0º to 360º in 5º steps. Kappa angles from 0 to 900 microns, in 150 microns steps, combined with two two variants of MIOL centration were tested: in the corneal apex or in the center of the entrance pupil. A p-value ≤ 0.05 was considered significant. RESULTS: There were statistically significant differences of the IQ depending of the intraocular orientation of the MIOL. If kappa angle was increased, there was a statistically significant decrease of the IQ. The IQ maintained stable when the optimal intraocular orientation was re-calculated for each kappa angle. In general, the inter-variability of the results between subjects was very high. There were no strong evidences supporting that there exists a preferable centration point. CONCLUSIONS: Our results suggest that kappa angle theoretically affects significantly the performance of asymmetric MIOL implantation. However, its negative effect can be compensated if a customized intraocular orientation is calculated taking into account the presence of the kappa angle


No disponible


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Aberrações de Frente de Onda da Córnea/fisiopatologia , Lentes Intraoculares Multifocais/normas , Modelagem Computacional Específica para o Paciente/normas , Estudos de Casos e Controles , Desenho de Prótese , Aberrações de Frente de Onda da Córnea/cirurgia , Aberrações de Frente de Onda da Córnea/patologia , Valores de Referência , Ilustração Médica , Reprodutibilidade dos Testes
14.
Optom Vis Sci ; 98(3): 289-294, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33633020

RESUMO

SIGNIFICANCE: The SVOne may prove useful to quickly and easily assess refractive correction needs in community screenings and low-resource settings, but not all subjects were testable with the device. PURPOSE: This study aimed to compare the SVOne handheld, smartphone-based wavefront aberrometer with a tabletop autorefractor in identifying refractive errors in elderly subjects. METHODS: Participants 50 years or older at community eye screenings with visual acuity worse than 20/40 in either eye underwent autorefraction followed by two SVOne trials. Power vectors of right eye data were analyzed. RESULTS: Of 84 subjects who underwent autorefraction, 67 (79.8%) were successfully autorefracted with the SVOne, of whom 82.1% (55/67) had a successful repeat reading. Mean M (spherical equivalent) values from tabletop and handheld autorefraction were -0.21 D (95% confidence interval [CI], -0.71 to +0.29 D) and -0.29 D (95% CI, -0.79 to +0.21 D), respectively (P > .05). Mean astigmatism values from tabletop and handheld devices were +1.06 D (95% CI, 0.87 to 1.26 D) and +1.21 D (95% CI, 0.99 to 1.43 D), respectively (P > .05). Intraclass correlation coefficients between devices were 0.95 (95% CI, 0.93 to 0.97) for M, 0.78 (95% CI, 0.66 to 0.86) for J0, and 0.45 (95% CI, 0.24 to 0.63) for J45 (P < .05 for all). Excellent test-retest correlation between SVOne measurements was noted for M (Pearson correlation [r] = 0.96; P < .05), but a weaker correlation was noted for J0 and J45 (r = 0.67 and r = 0.63 [P < .05 for both], respectively). CONCLUSIONS: The SVOne provided strong agreement for M, with the majority of readings within ±1.00 D of each other, when compared with the tabletop autorefractor. A weaker but still good correlation was noted for astigmatism. Similar findings were noted when assessing repeatability.


Assuntos
Aberrometria/instrumentação , Aberrações de Frente de Onda da Córnea/diagnóstico , Refração Ocular/fisiologia , Erros de Refração/diagnóstico , Seleção Visual/métodos , Idoso , Idoso de 80 Anos ou mais , Serviços de Saúde Comunitária/métodos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Erros de Refração/fisiopatologia , Reprodutibilidade dos Testes , Acuidade Visual/fisiologia
15.
Cornea ; 40(9): 1110-1116, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-33591041

RESUMO

PURPOSE: To study the change in contrast sensitivities in eyes with Fuchs endothelial dystrophy and bullous keratopathy after Descemet membrane endothelial keratoplasty (DMEK). METHODS: In this prospective study, 50 pseudophakic eyes of 50 patients who received DMEK surgery at the Charité-Universitätsmedizin Berlin were included. Visual acuity; contrast sensitivity using OPTEC 6500 at spatial frequencies of 1.5, 3, 6, 12, and 18 cycles/degree in photopic and mesopic light with and without glare; central corneal thickness (CCT); and anterior and posterior corneal aberrations were measured preoperatively and at 3 and 12 months postoperatively. RESULTS: Best-corrected visual acuity (preoperative 0.67 ± 0.46 and after 12 months 0.19 ± 0.16 LogMAR, P < 0.001) and photopic and mesopic contrast sensitivities with and without glare improved significantly, whereas CCT decreased significantly (preoperative 677 ± 114 µm, after 12 months 527 ± 29 µm, P < 0.001). Preoperative CCT correlates significantly with preoperative photopic contrast sensitivity (correlation coefficient -0.462, P = 0.002), and postoperative total anterior aberrations correlates with postoperative photopic contrast sensitivity (correlation coefficient -0.361, P = 0.006). CONCLUSIONS: Photopic and mesopic contrast sensitivities, especially with glare, are impaired in patients with Fuchs endothelial dystrophy and bullous keratopathy. The extent of the corneal thickening seems to mainly influence the contrast sensitivity preoperatively. DMEK surgery improves the contrast sensitivity significantly. However, higher postoperative anterior corneal aberrations limit the postoperative contrast sensitivities.


Assuntos
Vesícula/cirurgia , Sensibilidades de Contraste/fisiologia , Doenças da Córnea/cirurgia , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior , Distrofia Endotelial de Fuchs/cirurgia , Idoso , Idoso de 80 Anos ou mais , Vesícula/fisiopatologia , Contagem de Células , Visão de Cores/fisiologia , Doenças da Córnea/fisiopatologia , Perda de Células Endoteliais da Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/fisiopatologia , Endotélio Corneano/patologia , Feminino , Distrofia Endotelial de Fuchs/fisiopatologia , Humanos , Masculino , Visão Mesópica/fisiologia , Complicações Pós-Operatórias , Período Pós-Operatório , Estudos Prospectivos , Recuperação de Função Fisiológica/fisiologia
16.
Invest Ophthalmol Vis Sci ; 62(2): 15, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33570601

RESUMO

Purpose: Keratoconus results in image quality loss in one or both eyes due to increased corneal distortion. This study quantified the depth of monocular suppression in keratoconus due to this image quality loss using a binocular contrast rivalry paradigm. Methods: Contrast rivalry was induced in 50 keratoconic cases (11-31 years) and 12 age-matched controls by dichoptically viewing orthogonal Gabor patches of 5 cycles per degree (cpd) and 1.5 cpd spatial frequency for 120 seconds with their best-corrected spectacles and rigid gas permeable (RGP) contact lenses. The dwell time on each eye's percept was determined at baseline (100% contrast bilaterally) and at varying contrast levels (80-2.5%) in the stronger eye of keratoconus or dominant eye of controls. The contrast reduction needed in the stronger eye to balance dwell times on both eyes was considered a measure of suppression depth. Results: At baseline with 5 cpd stimuli and spectacle correction, the rivalry switches were less frequent and biased toward the stronger eye of cases, all relative to controls (P < 0.001). The contrast balance point of cases (20.51% [10.7-61%]) was lower than the controls (99.80% [98.6-100%]; P < 0.001) and strongly associated with the overall and interocular difference in disease severity (r = 0.83, P < 0.001). The suppression depth reduced for 1.5 cpd (70.8% [21.7-94%]), relative to 5 cpd stimulus (P < 0.001) and with contact lenses (80.1% [49.5-91.7%]), relative to spectacles (P < 0.001). Conclusions: The eye with lesser disease severity dominates binocular viewing in keratoconus. The suppression depth of the poorer eye depends on the extent of bilateral disease severity, optical correction modality, and the target spatial frequency.


Assuntos
Córnea/diagnóstico por imagem , Aberrações de Frente de Onda da Córnea/fisiopatologia , Ceratocone/fisiopatologia , Visão Binocular/fisiologia , Acuidade Visual , Adolescente , Adulto , Criança , Lentes de Contato , Aberrações de Frente de Onda da Córnea/diagnóstico , Óculos , Feminino , Humanos , Ceratocone/diagnóstico , Ceratocone/terapia , Masculino , Índice de Gravidade de Doença , Adulto Jovem
17.
Am J Ophthalmol ; 225: 69-75, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33385369

RESUMO

PURPOSE: This study sought to evaluate the demographic profile, clinical features, topographic features, and biomechanical and aberrometric characteristics in pediatric keratoconus (KC). DESIGN: Cross-sectional study. METHODS: Pediatric KC cases <18 years of age were evaluated at a tertiary hospital. Main outcome measurements were demographic profile, clinical features, visual acuity, corneal topography, aberrometry, and biomechanical and confocal microscopy findings. RESULTS: A total of 116 eyes of 62 consecutive patients were recruited with a mean ± age of 14.7 ± 2.77 years (range: 8-18 years); 46 of 62 (88%) were males; 57 of 62 cases (92%) had bilateral disease; 53 of 116 eyes (46%) had progressive KC; and 9 of 116 eyes (8%) had acute hydrops. Systemic associations were found in 6 of 62 patients (9.7%) and ocular associations in 77 of 116 eyes (66.3%); 68 of 116 eyes (58.6%) had associated vernal keratoconjunctivitis (VKC). Among eyes with VKC, 29 of 68 eyes (46%) were in stage IV KC, versus 25% of eyes with no VKC (P = .004). The mean ± SD refractive spherical equivalent was -4.72 ± 3.32 diopters (D), and refractive astigmatism was 3.69 ± 3.09 D. The mean values of maximum keratometry, thinnest pachymetry, and corneal higher-order aberrations were 60.89 ± 10.9 D, 396.05 ± 95.03 µm, and 1.18 ± 1.2 µm, respectively. Values of corneal hysteresis and corneal resistance factor correlated with the stage of KC (r = -0.26; P = .007). CONCLUSIONS: Pediatric KC was commonly associated with VKC in this cohort. Eyes with VKC had more severe KC than those without VKC. Nearly half of the patients presented with progressive disease. Corneal biomechanical changes correlated well with stage of KC in this pediatric age group.


Assuntos
Fenômenos Biomecânicos/fisiologia , Córnea/fisiopatologia , Topografia da Córnea , Aberrações de Frente de Onda da Córnea/fisiopatologia , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Aberrometria , Adolescente , Criança , Conjuntivite Alérgica/fisiopatologia , Paquimetria Corneana , Estudos Transversais , Feminino , Humanos , Masculino , Estudos Prospectivos , Refração Ocular/fisiologia , Acuidade Visual/fisiologia
18.
Curr Eye Res ; 46(1): 14-22, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32538202

RESUMO

PURPOSE: To comparatively evaluate the long-term visual, refractive, topographic and aberrometric outcomes of conventional corneal collagen crosslinking (CXL) in the management of pediatric versus adult progressive keratoconus patients. MATERIALS AND METHODS: Retrospective, cross-sectional review of consecutive progressive keratoconus cases of corneal standard CXL using a standardized protocol for treatment and examinations was performed. Best spectacle-corrected distance visual acuity (CDVA), manifest refraction, slit lamp biomicroscopy, corneal tomography, corneal aberrometry and endothelial cell counts were evaluated at baseline and yearly at all postoperative follow-up examinations after month-12. The outcomes were analyzed by dividing the patients into 2 age groups; pediatric (≤18 years) versus adult (>18 years). RESULTS: Eighty-eight eyes (54 patients) in the pediatric and 104 eyes (68 patients) in the adult age groups completed 3 years follow-up. Compared to baseline, the mean CDVA, manifest refraction, keratometric readings, tomographic and aberrometric parameters improved statistically significantly in both groups at postoperative year-3 and year-4, without any statistically significant between-group differences. No change in the mean endothelial cell density (p > .05), or no sight threating complication was encountered in any patient eye in either group. In a subset of patients who were followed for 4 years (71 eyes in the pediatric and 70 eyes in the adult age groups), the outcome analyses were again similar between-groups. CONCLUSION: Conventional corneal CXL effectively halts the progression of keratoconus in both pediatric and adult age groups in long-term follow-up with similar visual, refractive, tomographic and aberrometric efficacy in both groups.


Assuntos
Aberrações de Frente de Onda da Córnea/fisiopatologia , Reagentes de Ligações Cruzadas , Ceratocone/tratamento farmacológico , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Refração Ocular/fisiologia , Acuidade Visual/fisiologia , Adolescente , Adulto , Contagem de Células , Criança , Colágeno/metabolismo , Paquimetria Corneana , Substância Própria/efeitos dos fármacos , Substância Própria/metabolismo , Estudos Transversais , Endotélio Corneano/patologia , Feminino , Seguimentos , Humanos , Ceratocone/fisiopatologia , Masculino , Estudos Retrospectivos , Riboflavina/uso terapêutico , Microscopia com Lâmpada de Fenda , Tomografia , Raios Ultravioleta , Adulto Jovem
19.
Cornea ; 40(2): 188-193, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-32947394

RESUMO

PURPOSE: To compare the safety and efficacy of topography-guided customized corneal cross-linking (PiXL) with standard cross-linking (CXL) for the treatment of progressive keratoconus. METHODS: In a prospective interventional analysis, the eyes of patients with progressive keratoconus underwent standard cross-linking (homogenous 9-mm ultraviolet-A irradiation of 9 mW/cm2 delivering a total fluence of 5.4J/cm2) versus topography-guided customized cross-linking (30 mW/cm2 pulsed irradiance with a total fluence ranging from 5.4 to 15 J/cm2, in concentric circles centered on the posterior float maximum). The following parameters were analyzed at the preoperative, 1-month, 6-month, and 1-year postoperative visits: corrected spectacle distance visual acuity, manifest refraction including sphere, cylinder and mean refractive spherical equivalent, corneal tomography, higher order aberration profile, and endothelial cell count. Anterior segment optical coherence tomography evaluation was performed at the 1-month postoperative visit to assess the depth of the demarcation line. RESULTS: Sixty-four eyes of 45 patients (32 eyes in each group) were included. There was a significant reduction in maximum keratometry and IS asymmetry in the PiXL group at both the 6-month and 1-year postoperative visits (P = 0.001 and 0.06). Corrected spectacle distance visual acuity improved significantly in the PiXL (0.05 ± 0.08 logarithm of the minimum angle of resolution, P = 0.02) versus the standard CXL (0.01 ± 0.025 logarithm of the minimum angle of resolution, P = 0.26) group. A greater depth of a stromal demarcation line was observed in the customized CXL group (P = 0.02). No significant complications were noted in either cohort. CONCLUSIONS: PiXL demonstrated similar safety with significantly greater keratometry flattening and corneal regularization vis-à-vis standard CXL. This resulted in significant improvement of spectacle corrected visual acuity for eyes with mild-to-moderate keratoconus.


Assuntos
Reagentes de Ligações Cruzadas , Ceratocone/tratamento farmacológico , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Adulto , Contagem de Células , Colágeno/metabolismo , Substância Própria/efeitos dos fármacos , Substância Própria/metabolismo , Topografia da Córnea , Aberrações de Frente de Onda da Córnea/fisiopatologia , Endotélio Corneano/patologia , Feminino , Humanos , Ceratocone/metabolismo , Ceratocone/fisiopatologia , Masculino , Estudos Prospectivos , Refração Ocular/fisiologia , Riboflavina/uso terapêutico , Cirurgia Assistida por Computador , Tomografia de Coerência Óptica , Resultado do Tratamento , Raios Ultravioleta , Acuidade Visual/fisiologia , Adulto Jovem
20.
Cornea ; 40(10): 1276-1281, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33332893

RESUMO

PURPOSE: To evaluate the correlations between corneal biomechanical indices from dynamic Scheimpflug assessment and optical quality assessed as higher-order aberrations (HOAs) using a Hartmann-Shack ocular wavefront sensor in patients with keratoconus (KC). METHODS: In this prospective, observational case series, the eyes with KC or KC suspect (KCS) from Osaka University Hospital, Osaka, Japan, were analyzed. Corneal biomechanical assessment was performed using Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany), and ocular wavefront aberrations were measured using the KR-1W (Topcon Corp, Tokyo, Japan). Correlations between the biomechanical indices and ocular HOAs were assessed. Corneal biomechanical indices included the deformation amplitude ratio within 2 mm, integrated radius, stiffness parameter at the first applanation, and the linear Corvis Biomechanical Index. Wavefront data of the central 4-mm region were expanded up to the sixth order of Zernike polynomials. The magnitudes of trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration were calculated by Zernike vector analysis and then used as ocular HOA parameters along with total HOAs. RESULTS: Thirty-four KC eyes and 37 KCS eyes were included. KC eyes showed significant correlations between ocular HOAs and biomechanics, whereas there were few significant correlations in KCS eyes. In KC eyes, deformation amplitude ratio within 2 mm, integrated radius, and Corvis Biomechanical Index beta showed stronger correlations with coma among the wavefront parameters. CONCLUSIONS: Corneal biomechanical indices correlated with ocular HOAs in patients with KC. In particular, there was a strong association with the increase in coma caused by inferosuperior asymmetry of the shape of the cornea in patients with KC.


Assuntos
Fenômenos Biomecânicos/fisiologia , Córnea/fisiopatologia , Ceratocone/fisiopatologia , Refração Ocular/fisiologia , Acuidade Visual/fisiologia , Aberrometria , Adolescente , Adulto , Idoso , Criança , Topografia da Córnea , Aberrações de Frente de Onda da Córnea/fisiopatologia , Elasticidade/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Visão Ocular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...