Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
J Food Sci ; 88(12): 4928-4941, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37905708

RESUMO

This study validated an analytical technique using headspace gas chromatography with flame ionization detection to quantify acrylonitrile monomer with a quantification limit of 0.10 ± 0.04 µg kg-1 . Subsequently, the acrylonitrile migration from polypropylene granules was evaluated in food simulants water and ethanol (50% v/v) and at two temperatures (20 ± 1°C and 44 ± 2°C) for up to 6 weeks, representing the service time of a bottle. From the experimental data obtained, pseudo-second-order kinetics were adjusted to represent the acrylonitrile migration into the simulants. For water, equilibrium concentrations of 13.58 and 16.58 µg kg-1 at 20 and 44°C, respectively, were obtained, while for 50% ethanol, 15.07 and 16.40 µg kg-1 were obtained for the same temperatures. The experimental results and the values estimated from the migration kinetics indicate that the maximum acrylonitrile concentration will not exceed the tolerable specific limit established in regulations. PRACTICAL APPLICATION: The migration of compounds such as acrylonitrile can be a drawback resulting in an undesirable reduction in the shelf life of liquid foods packaged in bottles made of materials such as polypropylene. In this paper, acrylonitrile migration kinetics and a methodology are proposed to determine whether the tolerable migration limits are ever reached, which can serve as a tool for producers of this type of packaging of food to predict shelf life.


Assuntos
Acrilonitrila , Embalagem de Alimentos , Polipropilenos , Acrilonitrila/análise , Etanol/química , Água/química , Contaminação de Alimentos/análise
2.
Waste Manag ; 70: 212-221, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28967530

RESUMO

Due to the continual increase in waste generated from electronic devices, the management of plastics, which represents between 10 and 30% by weight of waste electrical and electronic equipment (WEEE or e-waste), becomes indispensable in terms of environmental and economic impacts. Considering the importance of acrylonitrile-butadiene-styrene (ABS), polycarbonate (PC), and their blends in the electronics and other industries, this study presents a new application of laser-induced breakdown spectroscopy (LIBS) for the fast and direct determination of PC and ABS concentrations in blends of these plastics obtained from samples of e-waste. From the LIBS spectra acquired for the PC/ABS blend, multivariate calibration models were built using partial least squares (PLS) regression. In general, it was possible to infer that the relative errors between the theoretical or reference and predicted values for the spiked samples were lower than 10%.


Assuntos
Acrilonitrila/análise , Butadienos/análise , Resíduo Eletrônico/análise , Plásticos/química , Cimento de Policarboxilato/análise , Poliestirenos/análise , Gerenciamento de Resíduos/métodos , Lasers , Análise Espectral
3.
Arq. bras. med. vet. zootec. (Online) ; 68(5): 1168-1176, set.-out. 2016. ilus
Artigo em Inglês | VETINDEX | ID: vti-16498

RESUMO

The purpose of this study was to evaluate acrylonitrile butadiene styrene (ABS) and polyamide implants in rabbits submitted to evisceration at the macroscopic and microstructure level and to assess clinical response and histopathological changes as well. For the experimental study implants of 12mm diameter were prepared by rapid prototyping, weighed and the outer and inner surfaces evaluated macroscopically and by electron microscopy. In addition, a compression test was performed and ultrastructural damage was then determined. After evisceration of the left eyeball, nine New Zealand rabbits received ABS implants and nine others received polyamide implants. The animals were assessed daily for 15 days after surgery and every seven days until the end of the study (90 days). Histopathological evaluation was performed at 15, 45 and 90 days after surgery. The ABS implants weighed approximately 0.44g, while the polyamide ones weighed 0.61g. Scanning electron microscopy demonstrated that the ABS implants had regular-sized, equidistant micropores, while the polyamide ones showed micropores of various sizes. The force required to fracture the ABS implant was 14.39 ±0.60 Mpa, while for the polyamide one, it was 16.80 ±1.05 Mpa. Fifteen days after surgery, we observed centripetal tissue infiltration and scarce inflammatory infiltrate. Implants may be used in the filling of anophthalmic cavities, because they are inert, biocompatible and allow tissue integration.(AU)


Avaliou-se a macroscopia, a microestrutura, a resposta clínica e histopatológica de implantes de acrilonitrila butadieno estireno (ABS) e poliamida em coelhos submetidos à evisceração. Para o estudo experimental, os implantes foram elaborados por meio de prototipagem rápida, com 12mm de diâmetro, pesados e tiveram suas superfícies avaliadas macroscopicamente e por microscopia eletrônica de varredura. Adicionalmente, foi realizado ensaio de compressão para determinar a força necessária para fraturar os implantes. Após a evisceração do olho esquerdo, nove coelhos da raça Nova Zelândia receberam implantes de poliamida e nove outros receberam implantes de ABS. Os animais foram avaliados diariamente nos primeiros 15 dias após a cirurgia e a cada sete dias até o fim do período experimental (90 dias). Avaliação histopatológica foi realizada aos 15, 45 e 90 dias após a cirurgia. Os implantes de ABS pesaram 0,44g, e os de poliamida 0,61g. A microscopia eletrônica de varredura demonstrou que os implantes de ABS eram formados por microporos equidistantes, enquanto os de poliamida apresentavam microporos de vários tamanhos. A força necessária para fraturar os implantes de ABS foi de 14.39±0.60 Mpa, enquanto para os de poliamida foi de 16.80±1.05Mpa. Quinze dias após a cirurgia, foi observada infiltração fibrovascular centrípeta. Os implantes podem ser utilizados para correção de cavidades anoftálmicas por se mostrarem inertes, biocompatíveis e permitirem a infiltração tecidual.(AU)


Assuntos
Animais , Coelhos , Evisceração do Olho/veterinária , Olho Artificial/veterinária , Polímeros , Materiais Biocompatíveis/análise , Acrilonitrila/análise , Butadienos/análise , Microscopia Eletrônica de Varredura/veterinária , Nylons
4.
Arq. bras. med. vet. zootec ; Arq. bras. med. vet. zootec. (Online);68(5): 1168-1176, set.-out. 2016. ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-827891

RESUMO

The purpose of this study was to evaluate acrylonitrile butadiene styrene (ABS) and polyamide implants in rabbits submitted to evisceration at the macroscopic and microstructure level and to assess clinical response and histopathological changes as well. For the experimental study implants of 12mm diameter were prepared by rapid prototyping, weighed and the outer and inner surfaces evaluated macroscopically and by electron microscopy. In addition, a compression test was performed and ultrastructural damage was then determined. After evisceration of the left eyeball, nine New Zealand rabbits received ABS implants and nine others received polyamide implants. The animals were assessed daily for 15 days after surgery and every seven days until the end of the study (90 days). Histopathological evaluation was performed at 15, 45 and 90 days after surgery. The ABS implants weighed approximately 0.44g, while the polyamide ones weighed 0.61g. Scanning electron microscopy demonstrated that the ABS implants had regular-sized, equidistant micropores, while the polyamide ones showed micropores of various sizes. The force required to fracture the ABS implant was 14.39 ±0.60 Mpa, while for the polyamide one, it was 16.80 ±1.05 Mpa. Fifteen days after surgery, we observed centripetal tissue infiltration and scarce inflammatory infiltrate. Implants may be used in the filling of anophthalmic cavities, because they are inert, biocompatible and allow tissue integration.(AU)


Avaliou-se a macroscopia, a microestrutura, a resposta clínica e histopatológica de implantes de acrilonitrila butadieno estireno (ABS) e poliamida em coelhos submetidos à evisceração. Para o estudo experimental, os implantes foram elaborados por meio de prototipagem rápida, com 12mm de diâmetro, pesados e tiveram suas superfícies avaliadas macroscopicamente e por microscopia eletrônica de varredura. Adicionalmente, foi realizado ensaio de compressão para determinar a força necessária para fraturar os implantes. Após a evisceração do olho esquerdo, nove coelhos da raça Nova Zelândia receberam implantes de poliamida e nove outros receberam implantes de ABS. Os animais foram avaliados diariamente nos primeiros 15 dias após a cirurgia e a cada sete dias até o fim do período experimental (90 dias). Avaliação histopatológica foi realizada aos 15, 45 e 90 dias após a cirurgia. Os implantes de ABS pesaram 0,44g, e os de poliamida 0,61g. A microscopia eletrônica de varredura demonstrou que os implantes de ABS eram formados por microporos equidistantes, enquanto os de poliamida apresentavam microporos de vários tamanhos. A força necessária para fraturar os implantes de ABS foi de 14.39±0.60 Mpa, enquanto para os de poliamida foi de 16.80±1.05Mpa. Quinze dias após a cirurgia, foi observada infiltração fibrovascular centrípeta. Os implantes podem ser utilizados para correção de cavidades anoftálmicas por se mostrarem inertes, biocompatíveis e permitirem a infiltração tecidual.(AU)


Assuntos
Animais , Coelhos , Materiais Biocompatíveis/análise , Evisceração do Olho/veterinária , Olho Artificial/veterinária , Polímeros , Acrilonitrila/análise , Butadienos/análise , Microscopia Eletrônica de Varredura/veterinária , Nylons
5.
Waste Manag Res ; 33(6): 543-9, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26022280

RESUMO

Polymeric materials constitute a considerable fraction of waste computer equipment and polymers acrylonitrile-butadiene-styrene and high-impact polystyrene are the main thermoplastic polymeric components found in waste computer equipment. Identification, separation and characterisation of additives present in acrylonitrile-butadiene-styrene and high-impact polystyrene are fundamental procedures to mechanical recycling of these polymers. The aim of this study was to evaluate the methods for identification of acrylonitrile-butadiene-styrene and high-impact polystyrene from waste computer equipment in Brazil, as well as their potential for mechanical recycling. The imprecise utilisation of symbols for identification of the polymers and the presence of additives containing toxic elements in determinate computer devices are some of the difficulties found for recycling of acrylonitrile-butadiene-styrene and high-impact polystyrene from waste computer equipment. However, the considerable performance of mechanical properties of the recycled acrylonitrile-butadiene-styrene and high-impact polystyrene when compared with the virgin materials confirms the potential for mechanical recycling of these polymers.


Assuntos
Acrilonitrila/análise , Butadienos/análise , Resíduo Eletrônico/análise , Estireno/análise , Brasil , Computadores , Fenômenos Mecânicos , Poliestirenos/análise , Reciclagem , Reologia
6.
J Occup Environ Med ; 57(2): 134-45, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25612296

RESUMO

OBJECTIVES: To update a cohort study of chemical workers and reevaluate lung cancer mortality in relation to acrylonitrile (AN) exposure. METHODS: Subjects were 2096 workers employed during 1955 to 2011. We identified 474 deaths through 2011, and quantitatively estimated worker exposures to AN. Analyses included national and county-based standardized mortality ratios and relative risk regression of internal cohort rates. RESULTS: We found no statistically significant excess mortality risks associated with Lima employment for any cause of death category, including lung cancer and other cancer sites implicated in previous studies. CONCLUSIONS: This update provides no evidence that exposure to AN at levels experienced by Lima workers is associated with an increased risk of lung cancer mortality, as suggested in original study. Earlier reported bladder cancer risks decreased to a much lower, not statistically significant level.


Assuntos
Acrilonitrila/análise , Carcinógenos/análise , Indústria Química/estatística & dados numéricos , Neoplasias/mortalidade , Doenças Profissionais/mortalidade , Exposição Ocupacional/análise , Acrilonitrila/toxicidade , Adulto , Idoso , Poluentes Ocupacionais do Ar/análise , Poluentes Ocupacionais do Ar/toxicidade , Carcinógenos/toxicidade , Causas de Morte , Neoplasias do Sistema Nervoso Central/mortalidade , Estudos de Coortes , Feminino , Humanos , Neoplasias Pulmonares/mortalidade , Masculino , Pessoa de Meia-Idade , Ohio/epidemiologia , Neoplasias da Próstata/mortalidade , Medição de Risco , Estados Unidos/epidemiologia , Neoplasias da Bexiga Urinária/mortalidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA