Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 261
Filtrar
1.
J Biomed Mater Res B Appl Biomater ; 112(4): e35401, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38520703

RESUMO

Hemorrhage is the second leading cause of death in patients under 46 years of age in the United States. Cessation of hemorrhage prevents hemorrhagic shock and tissue hypoxia. Controlling the bleed via direct pressure or tourniquet is often the first line of defense, but long-term care requires staples, hemostatic agents, or sealants that seal the vessel and restore blood flow. Here, we compare a new photocurable extracellular matrix sealant (pcECM) with low, medium, and high crosslink density formulations to a commercially available fibrin-based sealant, TISSEEL®. pcECM has potential uses in surgical and remote settings due to room temperature storage conditions and fast preparation time. Here, we determine if pcECM sealant can stop venous hemorrhage in a murine model, adhere to the wound site in vivo throughout the wound-healing process, and has the mechanical properties necessary for stopping hemorrhage. Adjusting pcECM crosslinking density significantly affected viscosity, swelling, burst strength, tensile strength, and elasticity of the sealant. 3-Dimensional ultrasound volume segmentations showed pcECM degrades to 17 ± 8% of its initial implant volume by day 28. Initially, local hemodynamic changes were observed, but returned close to baseline levels by day 28. Acute inflammation was observed near the puncture site in pcECM implanted mice, and we observed inflammatory markers at the 14-day explant for both sealants. pcECM and fibrin sealant successfully sealed the vessel in all cases, and consistently degraded over 14-28 days. pcECM is a durable sealant with tunable mechanical properties and possible uses in hemorrhage control and other surgical procedures.


Assuntos
Hemorragia , Adesivos Teciduais , Humanos , Camundongos , Animais , Hemorragia/prevenção & controle , Adesivo Tecidual de Fibrina/efeitos adversos , Cicatrização , Matriz Extracelular/metabolismo , Adesivos Teciduais/metabolismo
2.
Trials ; 24(1): 488, 2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-37525278

RESUMO

BACKGROUND: Recent advances in endoscopic endonasal transsphenoidal approaches (EETA) for skull base lesions have resulted in a significant increase in extent and complexity of skull base defects, demanding more elaborate and novel reconstruction techniques to prevent cerebrospinal fluid (CSF) leakage and to improve healing. Currently, commercially available fibrin sealants are often used to reinforce the skull base reconstruction. However, problems have been reported regarding hypersensitivity reactions, efficacy, and costs. This trial aims to investigate autologous leukocyte- and platelet-rich fibrin (L-PRF) membranes as an alternative for commercially available fibrin glues in EETA-related skull base reconstruction reinforcement. METHODS/DESIGN: This multicenter, prospective randomized controlled trial aims to demonstrate non-inferiority of L-PRF membranes compared to commercially available fibrin sealants in EETA cases (1) without intra-operative CSF-leak as dural or sellar floor closure reinforcement and (2) in EETA cases with intra-operative CSF-leak (or very large defects) in which a classic multilayer reconstruction has been made, as an additional sealing. The trial includes patients undergoing EETA in three different centers in Belgium. Patients are randomized in a 1:1 fashion comparing L-PRF with commercially available fibrin sealants. The primary endpoint is postoperative CSF leakage. Secondary endpoints are identification of risk factors for reconstruction failure, assessment of rhinological symptoms, and interference with postoperative imaging. Additionally, a cost-effectiveness analysis is performed. DISCUSSION: With this trial, we will evaluate the safety and efficacy of L-PRF compared to commercially available fibrin sealants. TRIAL REGISTRATION: ClinicalTrials.gov NCT03910374. Registered on 10 April 2019.


Assuntos
Fibrina Rica em Plaquetas , Humanos , Vazamento de Líquido Cefalorraquidiano/etiologia , Vazamento de Líquido Cefalorraquidiano/prevenção & controle , Adesivo Tecidual de Fibrina/efeitos adversos , Estudos Multicêntricos como Assunto , Complicações Pós-Operatórias/prevenção & controle , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Retrospectivos , Base do Crânio/cirurgia , Estudos de Equivalência como Asunto
3.
Trials ; 24(1): 219, 2023 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-36959672

RESUMO

BACKGROUND: CSF leakage is a major complication after cranial surgery, thus, adequate dural closure must be performed. Commercially available fibrin sealants are currently considered the gold standard for dural closure, but problems have been reported regarding safety, efficacy, and costs. This trial aims to investigate autologous leukocyte- and platelet-rich fibrin (L-PRF) as an alternative to commercially available fibrin sealants. METHODS/DESIGN: This single-blinded, prospective randomized controlled interventional trial aims to demonstrate the non-inferiority of L-PRF compared to commercially available fibrin sealants for dural closure. This trial will include patients undergoing cranial neurosurgery (supratentorial and infratentorial) with intentional opening of the dura. Patients are randomized in a 1:1 fashion comparing L-PRF to commercially available fibrin sealants. The primary endpoint is postoperative CSF leakage within 12 weeks after surgery. Secondary endpoints are complications such as bleeding or wound infections. Additionally, a cost-effectiveness analysis is performed. DISCUSSION: With this trial, we will evaluate the safety and efficiency of L-PRF compared to commercially available fibrin sealants. TRIAL REGISTRATION: ClinicalTrials.gov NCT03812120. Registered on 22 January 2019.


Assuntos
Fibrina Rica em Plaquetas , Humanos , Estudos Prospectivos , Adesivo Tecidual de Fibrina/efeitos adversos , Complicações Pós-Operatórias/etiologia , Vazamento de Líquido Cefalorraquidiano/etiologia , Ensaios Clínicos Controlados Aleatórios como Assunto
4.
J Vasc Surg ; 77(3): 752-759.e2, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36441022

RESUMO

OBJECTIVE: The presence of endoleak was associated with the failure of endovascular aortic aneurysm repair (EVAR) treatment. The key to eliminating type II endoleak has shifted from reintervention to prevention. This study aimed to evaluate the effectiveness and safety of applying fibrin sealant to prevent type II endoleak in conjunction with EVAR. METHODS: All patients with abdominal aortic aneurysm who underwent EVAR from June 2019 to July 2021 were reviewed. Patients were grouped as Group A: standard EVAR with preemptive embolization and Group B: standard EVAR alone. The primary endpoint was the incidence of type II endoleak. The secondary endpoints were aneurysm sac regression, the inferior mesenteric artery patency, the numbers of patent lumbar arteries, and all-cause mortality. RESULTS: A total of 104 patients were included in Group A, and 116 were included in Group B. Technical success rate was 100%. The overall incidence of type II endoleak in Group A was significantly lower than that in Group B (4.8% vs 19.0%). The mean time of freedom from type II endoleak was 22.71 months for Group A (95% confidence interval, 21.59-23.83 months) and 19.89 months for Group B (95% confidence interval, 18.08-21.70 months). The Kaplan-Meier estimate of freedom from type II endoleak showed a significantly longer duration of freedom from type II endoleak in Group A (81.0% vs 95.2%). Group A showed a continuous sac regression tendency. In Group B, the sac volume decreased within 12 months but increased by 3.07 cm3 at 24 months. No complications were noted in both groups. CONCLUSIONS: Nonselective preemptive embolization with porcine fibrin sealant during EVAR was safe and effective in preventing type II endoleak in the short and mid-term. Preemptive embolization can lead to a significantly higher sac regression rate. Larger patient populations and longer follow-ups with randomized control designed trials are expected to verify the long-term effectiveness and safety of preemptive embolization in preventing type II endoleak.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Embolização Terapêutica , Procedimentos Endovasculares , Animais , Suínos , Endoleak/etiologia , Adesivo Tecidual de Fibrina/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Aneurisma da Aorta Abdominal/cirurgia , Embolização Terapêutica/efeitos adversos , Estudos Retrospectivos
5.
BMC Musculoskelet Disord ; 23(1): 827, 2022 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-36045358

RESUMO

BACKGROUND: We assessed quality of life (QoL) of patients undergoing surgery for proximal femur fracture and performed a cost-effectiveness analysis of haemostatic drugs for reducing postoperative bleeding. METHODS: We analysed data from an open, multicentre, parallel, randomized controlled clinical trial (RCT) that assessed the efficacy and safety of tranexamic acid (TXA group) and fibrin glue (FG group) administered topically prior to surgical closure, compared with usual haemostasis methods (control group). For this study we conducted a cost-effectiveness analysis of these interventions from the Spanish Health System perspective, using a time horizon of 12 months. The cost was reported in $US purchasing power parity (USPPP). We calculated the incremental cost-effectiveness ratio (ICER) per QALY (quality-adjusted life-year). RESULTS: We included 134 consecutive patients from February 2013 to March 2015: 42 patients in the TXA group, 46 in the FG group, and 46 in the control group. Before the fracture, EuroQol visual analogue scale (EQ-VAS) health questionnaire score was 68.6. During the 12 months post-surgery, the intragroup EQ-VAS improved, but without reaching pre-fracture values. There were no differences between groups for EQ-VAS and EuroQol 5 dimensions 5 levels (EQ-5D-5L) health questionnaire score, nor in hospital stay costs or medical complication costs. Nevertheless, the cost of one FG treatment was significantly higher (399.1 $USPPP) than the cost of TXA (12.9 $USPPP) or usual haemostasis (0 $USPPP). When comparing the cost-effectiveness of the interventions, FG was ruled out by simple dominance since it was more costly (13,314.7 $USPPP) than TXA (13,295.2 $USPPP) and less effective (utilities of 0.0532 vs. 0.0734, respectively). TXA compared to usual haemostasis had an ICER of 15,289.6 $USPPP per QALY). CONCLUSIONS: There were no significant differences between the intervention groups in terms of postoperative changes in QoL. However, topical TXA was more cost-effective than FG or usual haemostasis. TRIAL REGISTRATION: ClinicalTrials.gov: NCT02150720. Date of registration 30/05/2014. Retrospectively registered.


Assuntos
Ácido Tranexâmico , Análise Custo-Benefício , Fêmur , Adesivo Tecidual de Fibrina/efeitos adversos , Humanos , Qualidade de Vida , Anos de Vida Ajustados por Qualidade de Vida , Ácido Tranexâmico/efeitos adversos
6.
Ann Allergy Asthma Immunol ; 129(1): 95-100, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35346879

RESUMO

BACKGROUND: In the diagnosis of perioperative anaphylaxis, it is essential to define its cause to prevent future reexposures, especially in children with Noonan Syndrome who are characterized by a large number of systemic features and wide-ranging dysmorphia. From an oral surgeon's point of view, apart from an increased risk of tumor incidence, diverse hematologic anomalies are of high concern. OBJECTIVE: Perioperative management of such patients often requires the use of fibrin sealants, which contain aprotinin. A certain number of anaphylaxis cases have been observed in our daily practice during such treatment, which was the reason for this evaluation. METHODS: The study was conducted to retrospectively review perioperative anaphylaxis grade II and above in children with Noonan Syndrome who underwent surgeries in the Department of Oral Surgery, Medical University of Lodz, between 2006 and 2021. RESULTS: Out of the 16 cases of suspected anaphylaxis to aprotinin, 14 were observed in children with Noonan Syndrome. The postoperative serologic screening revealed positive results for qualitative aprotinin-specific immunoglobulin (Ig) G, highly elevated quantitative aprotinin-specific IgG, and slightly elevated aprotinin-specific IgE antibodies. Interestingly, previous aprotinin administration or contact in the past 12 months was excluded. CONCLUSION: Given that fibrin sealants are typically used in various surgical practices and although the anaphylaxis reactions in such cases are rare, it is essential to be cautious in patients with RASopathies who are at a high risk of developing anaphylaxis.


Assuntos
Anafilaxia , Síndrome de Noonan , Aprotinina/efeitos adversos , Criança , Adesivo Tecidual de Fibrina/efeitos adversos , Humanos , Imunoglobulina G , Síndrome de Noonan/complicações , Estudos Retrospectivos
7.
Catheter Cardiovasc Interv ; 99(4): 1327-1334, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35019201

RESUMO

This study sought to evaluate a new method that uses injection of fibrin sealant under simultaneous balloon occlusion for the treatment of postinterventional access site bleeding complications. With the rising complexity of interventional procedures, iatrogenic false aneurysms and active bleeding has become more common. In general, these complications are associated with increased morbidity and mortality, especially if surgical repair is required. Although high success rates are reported for ultrasound-guided compression and ultrasound-guided thrombin injection, these methods are not always feasible. All procedures of fibrin sealant injection under simultaneous balloon occlusion for the treatment of postinterventional access site bleeding complications or pseudoaneurysm were prospectively collected. Additional data were retrospectively obtained and analyzed for all patients treated by this new method. In total, 53 patients were included from 2018 to 2021. Most of the access site complications were related to transcatheter aortic valve replacement (40%) or percutaneous coronary intervention (21%), but also to a wide variety of other procedures. Of the 53 patients, 30 had to be treated for false aneurysms and 23 for active bleeding. A high primary success rate of 94% was achieved. Recurrences of false aneurysms occurred in six patients, of which only one needed open surgical repair. Regarding complications, two peripheral embolisms, thereof one requiring additional stent implantation occurred. Balloon-assisted thrombin injection seems to be feasible and safe. It provides a new alternative to prevent surgery for patients where common techniques are unavailable or have failed.


Assuntos
Falso Aneurisma , Adesivo Tecidual de Fibrina , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/terapia , Artéria Femoral/cirurgia , Adesivo Tecidual de Fibrina/efeitos adversos , Humanos , Estudos Retrospectivos , Trombina , Resultado do Tratamento
8.
BMJ Open Ophthalmol ; 7(Suppl 2): A16, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-37282688

RESUMO

PURPOSE: To investigate the tolerability, security and long-term efficacy of lyophilized amniotic membrane (LAM) as an alternative to cryopreserved amniotic membrane in pterygium surgery. MATERIAL AND METHODS: Prospective case series of patients with primary nasal pterygium who undergone pterygium surgery and LAM implant either with sutures or glue. Postoperative follow-up was until month 24. Clinical and cosmetic outcomes, quality of life (as ocular comfort), and complications were evaluated. RESULTS: LAM was stiff and easy to manipulate as well as no tearing occurred during surgery or suturing. 4 patients (3 males) had pterygium surgery and LAM implant two with sutures and the other two with glue. Ocular comfort was checked and similar among those patients with LAM glued or sutured. After 24 months, there were no issues about tolerability or adverse events. Lower cosmetic outcomes (recurrence) were stated in 3 patients. CONCLUSION: Our study showed that LAM could be an effective alternative to cryopreserved amniotic membrane for graft after pterygium excision surgery. Its main advantage, storage at room temperature, can make it of immediate availability. Further studies comparing clinical outcomes of pterygium surgery with cryopreserved amniotic membrane versus LAM would confirm the benefits of the last.


Assuntos
Pterígio , Masculino , Humanos , Pterígio/cirurgia , Adesivo Tecidual de Fibrina/efeitos adversos , Âmnio/transplante , Qualidade de Vida , Recidiva
9.
Cells ; 10(9)2021 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-34571972

RESUMO

Cell therapy strategies using mesenchymal stem cells (MSCs) carried in fibrin glue have shown promising results in regenerative medicine. MSCs are crucial for tissue healing because they have angiogenic, anti-apoptotic and immunomodulatory properties, in addition to the ability to differentiate into several specialized cell lines. Fibrin sealant or fibrin glue is a natural polymer involved in the coagulation process. Fibrin glue provides a temporary structure that favors angiogenesis, extracellular matrix deposition and cell-matrix interactions. Additionally, fibrin glue maintains the local and paracrine functions of MSCs, providing tissue regeneration through less invasive clinical procedures. Thus, the objective of this systematic review was to assess the potential of fibrin glue combined with MSCs in bone or cartilage regeneration. The bibliographic search was performed in the PubMed/MEDLINE, LILACS and Embase databases, using the descriptors ("fibrin sealant" OR "fibrin glue") AND "stem cells" AND "bone regeneration", considering articles published until 2021. In this case, 12 preclinical and five clinical studies were selected to compose this review, according to the eligibility criteria. In preclinical studies, fibrin glue loaded with MSCs, alone or associated with bone substitute, significantly favored bone defects regeneration compared to scaffold without cells. Similarly, fibrin glue loaded with MSCs presented considerable potential to regenerate joint cartilage injuries and multiple bone fractures, with significant improvement in clinical parameters and absence of postoperative complications. Therefore, there is clear evidence in the literature that fibrin glue loaded with MSCs, alone or combined with bone substitute, is a promising strategy for treating lesions in bone or cartilaginous tissue.


Assuntos
Regeneração Óssea , Condrogênese , Adesivo Tecidual de Fibrina/uso terapêutico , Transplante de Células-Tronco Mesenquimais , Células-Tronco Mesenquimais/metabolismo , Osteogênese , Medicina Regenerativa , Alicerces Teciduais , Animais , Adesivo Tecidual de Fibrina/efeitos adversos , Humanos , Transplante de Células-Tronco Mesenquimais/efeitos adversos , Modelos Animais , Coelhos , Ratos , Resultado do Tratamento , Cicatrização
10.
Thorac Cancer ; 12(14): 2126-2129, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34033235

RESUMO

Air leakage is a common complication after pulmonary resection, and fibrin glue is used as a sealant to reduce postoperative air leakage. It is generally recognized that fibrin glue-induced adverse events are rare. Herein, we report a rare case of suspected fibrin glue-induced acute eosinophilic pneumonia (AEP). A 72-year-old man underwent right lower lobectomy and mediastinal lymph node dissection for right lower lung cancer. Fibrin glue was sprayed to cover the interlobar surface of the right upper and middle lobes. On postoperative day 10, computed tomography (CT) revealed ground-glass shadows around the interlobar surface of the remaining lobes of the right lung. Although antibacterial drugs were administered for suspected bacterial pneumonia, fever spike, shortness of breath, and exacerbation of ground-glass shadows were observed. Peripheral blood and bronchoalveolar lavage fluid showed increased eosinophil count, supporting the diagnosis of AEP. Pneumonia resolved after prednisolone administration. At one-year follow-up, CT showed no AEP recurrence. Drug-induced pneumonia usually develops in the bilateral lung and rarely in the hemilateral lung. In this case, pneumonia was localized around the site covered with fibrin glue, suggesting fibrin glue-induced AEP. Thus, the use of fibrin glue should be carefully considered during pulmonary resection.


Assuntos
Adesivo Tecidual de Fibrina/efeitos adversos , Neoplasias Pulmonares/cirurgia , Pneumonectomia/métodos , Pneumonia/induzido quimicamente , Complicações Pós-Operatórias/induzido quimicamente , Eosinofilia Pulmonar/induzido quimicamente , Idoso , Glucocorticoides/administração & dosagem , Humanos , Masculino , Pneumonia/tratamento farmacológico , Complicações Pós-Operatórias/tratamento farmacológico , Prednisolona/administração & dosagem , Eosinofilia Pulmonar/tratamento farmacológico
11.
Front Immunol ; 12: 627541, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33708219

RESUMO

Background: Heterologous fibrin sealant (HFS) consists of a fibrinogen-rich cryoprecipitate extracted from Bubalus bubalis buffalo blood and a thrombin-like enzyme purified from Crotalus durissus terrificus snake venom. This study evaluated the safety and immunogenicity of HFS, estimated the best dose, and assessed its preliminary efficacy in the treatment of chronic venous ulcers (CVU). Methods: A phase I/II non-randomized, single-arm clinical trial was performed on 31 participants, accounting for a total of 69 active CVUs. All ulcers were treated with HFS, essential fatty acid, and Unna boot for 12 weeks. The outcomes assessed were: (1) primary safety, immunogenicity analyses, and confirmation of the lowest safe dose; (2) secondary promising efficacy by analyzing the healing process. Immunogenicity was evaluated using the serum-neutralizing (IgM and IgG) and non-neutralizing (IgA and IgE) antibody techniques against the product. The immuno-detection of IgE class antibodies was assessed using dot-blot assay before and at the end of treatment. Positive samples on dot-blot assays were subsequently analyzed by western blotting to verify the results. Results: No severe systemic adverse events related to the use of HFS were observed. Local adverse events potentially related to treatment include ulcer pain (52%), peri-ulcer maceration (16%), peri-ulcer pruritus (12%), critical colonization (8%), peri-ulcer eczema (4%), the opening of new ulcers (4%), and increased ulcerated area 4%). Neutralizing and non-neutralizing antibodies did not show significant deviations at any of the evaluated time points. Blot assays showed that all patients presented negative immunological reactions, either before or after treatment, with the thrombin-like enzyme component. In addition, two participants showed a positive immunological reaction to the cryoprecipitate component, while another two were positive before and during treatment. Regarding the secondary outcomes of preliminary efficacy, a total healing and significant reduction of the area was observed in 47.5 and 22%, respectively. A qualitative improvement was observed in the wound beds of unhealed ulcers. Conclusions: The investigational HFS bioproduct proved to be safe and non-immunogenic with a good preliminary efficacy for the treatment of CVU, according to the protocol and doses proposed. A multicentric phase III clinical trial will be necessary to verify these findings.


Assuntos
Adesivo Tecidual de Fibrina/uso terapêutico , Úlcera Varicosa/tratamento farmacológico , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença Crônica , Feminino , Adesivo Tecidual de Fibrina/efeitos adversos , Humanos , Imunoglobulinas/sangue , Masculino , Pessoa de Meia-Idade , Úlcera Varicosa/imunologia , Cicatrização
12.
Thorac Cardiovasc Surg ; 69(5): 466-469, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30727011

RESUMO

BACKGROUND: Prolonged air leakage is a problem that can frequently develop in patients with a secondary spontaneous pneumothorax (SSP) or in those who undergo thoracic surgery. However, the management of an air leak is difficult and reoperation might be avoided due to several reasons including adhesions. Herein, we introduce a fibrin glue application under pleurography (FGAP) and short-term outcomes in patients who underwent this procedure. METHODS: FGAP was performed in 20 patients with an intractable persistent air leakage who had poor lung function, comorbidities to undergo general anesthesia and were expected severe adhesions due to previous surgery. All medical records were retrospectively reviewed. RESULTS: Eighteen cases sealed soon after dropping the glue. One patient had a prolonged air leak for 12 days and another patient required an operation to control air leakage 16 days after the procedure. The mean duration of postoperative drainage was 4.17 ± 2.11 days (range: 3-14 days). No postprocedural complications were recorded. The mean duration of follow-up was 12.01 ± 5.02 months (range: 4-22 months). CONCLUSION: FGAP could be a treatment option to seal air leaks, especially in cases with intractable air leakage.


Assuntos
Adesivo Tecidual de Fibrina/uso terapêutico , Pneumotórax/terapia , Radiografia Intervencionista , Adesivo Tecidual de Fibrina/efeitos adversos , Humanos , Pneumotórax/diagnóstico por imagem , Radiografia Intervencionista/efeitos adversos , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
13.
Eur J Vasc Endovasc Surg ; 60(3): 469-478, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32620348

RESUMO

OBJECTIVE: In vascular and cardiac surgery, the ability to maintain haemostasis and seal haemorrhagic tissues is key. Fibrin and thrombin based sealants were introduced as a means to prevent or halt bleeding during surgery. Whether fibrin and thrombin sealants affect surgical outcomes is poorly established. A systematic review and meta-analysis was performed to examine the impact of fibrin or thrombin sealants on patient outcomes in vascular and cardiac surgery. DATA SOURCES: Cochrane CENTRAL, Embase, and MEDLINE, as well as trial registries, conference abstracts, and reference lists of included articles were searched from inception to December 2019. REVIEW METHODS: Studies comparing the use of fibrin or thrombin sealant with either an active (other haemostatic methods) or standard surgical haemostatic control in vascular and cardiac surgery were searched for. The Cochrane risk of bias tool and the ROBINS-I tool (Risk Of Bias In Non-randomised Studies - of Interventions) were used to assess the risk of bias of the included randomised and non-randomised studies; quality of evidence was assessed by the Grading of Recommendations Assessment, Development and Evaluation (GRADE) framework. Two reviewers screened studies, assessed risk of bias, and extracted data independently and in duplicate. Data from included trials were pooled using a random effects model. RESULTS: Twenty-one studies (n = 7 622 patients) were included: 13 randomised controlled trials (RCTs), five retrospective, and three prospective cohort studies. Meta-analysis of the RCTs showed a statistically significant decrease in the volume of blood lost (mean difference 120.7 mL, in favour of sealant use [95% confidence interval {CI} -150.6 - -90.7; p < .001], moderate quality). Time to haemostasis was also shown to be reduced in patients receiving sealant (mean difference -2.5 minutes [95% CI -4.0 - -1.1; p < .001], low quality). Post-operative blood transfusions, re-operation due to bleeding, and 30 day mortality were not significantly different for either RCTs or observational data. CONCLUSION: The use of fibrin and thrombin sealants confers a statistically significant but clinically small reduction in blood loss and time to haemostasis; it does not reduce blood transfusion. These Results may support selective rather than routine use of fibrin and thrombin sealants in vascular and cardiac surgery.


Assuntos
Perda Sanguínea Cirúrgica/prevenção & controle , Procedimentos Cirúrgicos Cardíacos , Adesivo Tecidual de Fibrina/administração & dosagem , Hemostasia , Hemostáticos/administração & dosagem , Hemorragia Pós-Operatória/prevenção & controle , Trombina/administração & dosagem , Adesivos Teciduais/administração & dosagem , Procedimentos Cirúrgicos Vasculares , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Adesivo Tecidual de Fibrina/efeitos adversos , Hemostáticos/efeitos adversos , Humanos , Hemorragia Pós-Operatória/etiologia , Fatores de Risco , Trombina/efeitos adversos , Fatores de Tempo , Adesivos Teciduais/efeitos adversos , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/efeitos adversos
14.
Vasc Endovascular Surg ; 54(6): 497-503, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32552570

RESUMO

INTRODUCTION: Arterial pseudoaneurysms (PSAs) are the most common access site complication following transarterial catheter intervention. Ultrasound-guided injection of thrombogenic substances into perfused arterial PSAs followed by compression therapy is a well-established and less invasive treatment option than surgical repair. Different agents are available to induce thrombosis including thrombin and a fibrin-based tissue glue, which is used as first-line treatment at our institution. This paper deals with our experience using ultrasound-guided fibrin glue injection (UGFI). MATERIALS AND METHODS: Retrospective data analysis: all patients (55) treated for iatrogenic femoral PSA following digital subtraction angiography of the lower extremities between January 1, 2010, and December 31, 2018, were included. Data on epidemiology, PSA location and size, vascular risk factors, fibrin glue injection (fibrin glue volume), primary success rate of UFGI, and complications related to the treatment were analyzed. RESULTS: A total of 55 consecutive femoral iatrogenic PSAs were treated during the defined period and 32 (58.2%) of the patients were female. Imaging was performed using ultrasound in all cases. The most common PSA location (80.0%) was the common femoral artery, mean PSA size (± SD) was 2.7 ± 1.2 cm, and neck length was 1.6 ± 1.0 cm. The dose (mean ± SD) of fibrin glue was 2.6 mL (± 1.0; maximum: 6 mL). Primary UGFI success rate was 87.3% and conversion rate to open surgery was 12.7%. Two (4%) patients required embolectomy for peripheral embolization after UGFI. CONCLUSION: Early results achieved with UGFI for treatment of iatrogenic femoral PSA are promising. In our cohort, UGFI was a safe and effective first-line alternative to traditional open surgery, which then was unnecessary in the vast majority of PSA cases. Further prospective studies for comparison of ultrasound-guided techniques should be encouraged.


Assuntos
Falso Aneurisma/terapia , Angiografia Digital/efeitos adversos , Artéria Femoral/lesões , Adesivo Tecidual de Fibrina/administração & dosagem , Doença Iatrogênica , Ultrassonografia de Intervenção , Lesões do Sistema Vascular/terapia , Idoso , Idoso de 80 Anos ou mais , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Estudos de Viabilidade , Feminino , Artéria Femoral/diagnóstico por imagem , Adesivo Tecidual de Fibrina/efeitos adversos , Humanos , Injeções Intra-Arteriais , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/etiologia
15.
Cochrane Database Syst Rev ; 3: CD009621, 2020 03 11.
Artigo em Inglês | MEDLINE | ID: mdl-32157697

RESUMO

BACKGROUND: Postoperative pancreatic fistula is one of the most frequent and potentially life-threatening complications following pancreatic resections. Fibrin sealants have been used in some centers to reduce postoperative pancreatic fistula. However, the use of fibrin sealants during pancreatic surgery is controversial. This is an update of a Cochrane Review last published in 2018. OBJECTIVES: To assess the safety, effectiveness, and potential adverse effects of fibrin sealants for the prevention of postoperative pancreatic fistula following pancreatic surgery. SEARCH METHODS: We searched trial registers and the following biomedical databases: the Cochrane Library (2019, Issue 2), MEDLINE (1946 to 13 March2019), Embase (1980 to 11 March 2019), Science Citation Index Expanded (1900 to 13 March 2019), and Chinese Biomedical Literature Database (CBM) (1978 to 13 March 2019). SELECTION CRITERIA: We included all randomised controlled trials that compared fibrin sealant (fibrin glue or fibrin sealant patch) versus control (no fibrin sealant or placebo) in people undergoing pancreatic surgery. DATA COLLECTION AND ANALYSIS: Two review authors independently identified the trials for inclusion, collected the data, and assessed the risk of bias. We performed the meta-analyses using Review Manager 5. We calculated the risk ratio (RR) for dichotomous outcomes (or a Peto odds ratio (OR) for very rare outcomes), and the mean difference (MD) for continuous outcomes, with 95% confidence intervals (CIs). MAIN RESULTS: We included 12 studies involving 1604 participants in the review. Application of fibrin sealants to pancreatic stump closure reinforcement after distal pancreatectomy We included seven studies involving 860 participants: 428 were randomised to the fibrin sealant group and 432 to the control group after distal pancreatectomy. Fibrin sealants may lead to little or no difference in postoperative pancreatic fistula (fibrin sealant 19.3%; control 20.1%; RR 0.96, 95% CI 0.68 to 1.35; 755 participants; four studies; low-quality evidence). Fibrin sealants may also lead to little or no difference in postoperative mortality (0.3% versus 0.5%; Peto OR 0.52, 95% CI 0.05 to 5.03; 804 participants; six studies; low-quality evidence), or overall postoperative morbidity (28.5% versus 23.2%; RR 1.23, 95% CI 0.97 to 1.58; 646 participants; three studies; low-quality evidence). We are uncertain whether fibrin sealants reduce reoperation rate (2.0% versus 3.8%; RR 0.51, 95% CI 0.15 to 1.71; 376 participants; two studies; very low-quality evidence) or length of hospital stay (MD 0.99 days, 95% CI -1.83 to 3.82; 371 participants; two studies; very low-quality evidence). The studies did not report serious adverse events, quality of life, or cost effectiveness. Application of fibrin sealants to pancreatic anastomosis reinforcement after pancreaticoduodenectomy We included four studies involving 393 participants: 186 were randomised to the fibrin sealant group and 207 to the control group after pancreaticoduodenectomy. We are uncertain whether fibrin sealants reduce postoperative pancreatic fistula (16.7% versus 11.7%; RR 1.14, 95% CI 0.28 to 4.69; 199 participants; two studies; very low-quality evidence). We are uncertain whether fibrin sealants reduce postoperative mortality (0.5% versus 2.4%; Peto OR 0.26, 95% CI 0.05 to 1.32; 393 participants; four studies; low-quality evidence) or length of hospital stay (MD 0.01 days, 95% CI -3.91 to 3.94; 323 participants; three studies; very low-quality evidence). There is probably little or no difference in overall postoperative morbidity (52.6% versus 50.3%; RR 1.04, 95% CI 0.87 to 1.24; 323 participants; three studies; moderate-quality evidence) between the groups. We are uncertain whether fibrin sealants reduce reoperation rate (5.2% versus 7.7%; RR 0.74, 95% CI 0.33 to 1.66; 323 participants; three studies, very low-quality evidence). The studies did not report serious adverse events, quality of life, or cost effectiveness. Application of fibrin sealants to pancreatic duct occlusion after pancreaticoduodenectomy We included two studies involving 351 participants: 188 were randomised to the fibrin sealant group and 163 to the control group after pancreaticoduodenectomy. Fibrin sealants may lead to little or no difference in postoperative mortality (8.4% versus 6.1%; Peto OR 1.41, 95% CI 0.63 to 3.13; 351 participants; two studies; low-quality evidence) or length of hospital stay (median 16 to 17 days versus 17 days; 351 participants; two studies; low-quality evidence). We are uncertain whether fibrin sealants reduce overall postoperative morbidity (32.0% versus 27.6%; RR 1.16, 95% CI 0.67 to 2.02; 351 participants; two studies; very low-quality evidence), or reoperation rate (13.6% versus 16.0%; RR 0.85, 95% CI 0.52 to 1.41; 351 participants; two studies; very low-quality evidence). Serious adverse events were reported in one study (169 participants; low-quality evidence): more participants developed diabetes mellitus when fibrin sealants were applied to pancreatic duct occlusion, both at three months' follow-up (33.7% fibrin sealant group versus 10.8% control group; 29 participants versus 9 participants) and 12 months' follow-up (33.7% fibrin sealant group versus 14.5% control group; 29 participants versus 12 participants). The studies did not report postoperative pancreatic fistula, quality of life, or cost effectiveness. AUTHORS' CONCLUSIONS: Based on the current available evidence, fibrin sealants may have little or no effect on postoperative pancreatic fistula in people undergoing distal pancreatectomy. The effects of fibrin sealants on the prevention of postoperative pancreatic fistula are uncertain in people undergoing pancreaticoduodenectomy.


Assuntos
Adesivo Tecidual de Fibrina/uso terapêutico , Pâncreas/cirurgia , Fístula Pancreática/prevenção & controle , Complicações Pós-Operatórias/prevenção & controle , Adesivos Teciduais/uso terapêutico , Adesivo Tecidual de Fibrina/efeitos adversos , Humanos , Tempo de Internação , Pancreatectomia/efeitos adversos , Pancreatectomia/métodos , Fístula Pancreática/mortalidade , Pancreaticoduodenectomia/efeitos adversos , Complicações Pós-Operatórias/mortalidade , Ensaios Clínicos Controlados Aleatórios como Assunto , Reoperação/estatística & dados numéricos
16.
Obstet Gynecol ; 135(2): 463-468, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31923069

RESUMO

Since a variety of procoagulant products, collectively called hemostatic agents, became available to surgeons in the mid-20th century, their use has increased across multiple specialties, including gynecology. Congruent with past research on the causes of regional variation in the practice of medicine, available evidence suggests that a central predictor for use of these products is physician preference rather than documented clinical necessity. Use of these products adds risks and avoidable cost. This article seeks to highlight specific gynecologic circumstances in which evidence and surgical judgment supports hemostatic agent use and other settings in which use should be reconsidered.


Assuntos
Adesivo Tecidual de Fibrina/uso terapêutico , Procedimentos Cirúrgicos em Ginecologia , Hemostáticos/uso terapêutico , Procedimentos Cirúrgicos Minimamente Invasivos , Administração Tópica , Perda Sanguínea Cirúrgica , Feminino , Adesivo Tecidual de Fibrina/efeitos adversos , Adesivo Tecidual de Fibrina/economia , Hemostáticos/efeitos adversos , Hemostáticos/economia , Humanos , Duração da Cirurgia , Medição de Risco
17.
J Invest Surg ; 33(3): 218-230, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30303427

RESUMO

BACKGROUND/PURPOSE: Rapid hemostasis, an essential prerequisite of good surgical practice during surgical bleeding, including soft tissue open surgery, often requires adjunctive treatment. We evaluated the safety and hemostatic effectiveness of a human plasma-derived fibrin sealant (FS Grifols) in soft tissue open surgery. METHODS: Patients with moderate soft tissue bleeding during open, urologic, gynecologic or general surgery were studied. The trial consisted of a preliminary phase (to familiarize investigators with the technique for FS Grifols application and the intraoperative procedures required by the clinical protocol) and a primary phase: in both phases, patients were randomized 1:1 to FS Grifols or Surgicel®. The primary efficacy endpoint, based on analysis of subjects in the primary phase of the study, was to evaluate whether FS Grifols was non-inferior to Surgicel® in achieving hemostasis, based on the proportion of subjects in both treatment groups who achieved hemostasis at the target bleeding site (TBS) by 4 min (T4) following the start of treatment application. Safety assessments included adverse events (AEs), vital signs, physical assessments, common clinical laboratory tests, viral markers, and immunogenicity. RESULTS: A total of 224 subjects were randomized (primary phase): FS Grifols (N = 116), Surgicel® (N = 108). The 95% CI at T4 for the ratio of the proportion of patients achieving hemostasis in the two treatment groups was 1.064 (0.934, 1.213), indicating non-inferiority for FS Grifols vs. Surgicel®. The rate of hemostasis at the TBS by T4 in both phases of the study was higher in the FS Grifols treatment group (preliminary phase: 90.2%; primary phase: 82.8%) than in the Surgicel® treatment group (preliminary phase: 78.8%; primary phase: 77.8%). Overall, reported AEs were as expected in surgical patients and were similar between the two treatment groups. CONCLUSIONS: This study shows the non-inferiority in time to hemostasis of FS Grifols vs. Surgicel as an adjunct to hemostasis in patients undergoing soft tissue open surgery, and a similar rate of AEs.


Assuntos
Perda Sanguínea Cirúrgica/prevenção & controle , Celulose Oxidada/administração & dosagem , Adesivo Tecidual de Fibrina/administração & dosagem , Hemostasia Cirúrgica/métodos , Hemostáticos/administração & dosagem , Procedimentos Cirúrgicos Operatórios/efeitos adversos , Adulto , Idoso , Perda Sanguínea Cirúrgica/estatística & dados numéricos , Celulose Oxidada/efeitos adversos , Feminino , Adesivo Tecidual de Fibrina/efeitos adversos , Hemostasia Cirúrgica/efeitos adversos , Hemostáticos/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Método Simples-Cego , Resultado do Tratamento , Adulto Jovem
18.
J Biomed Mater Res B Appl Biomater ; 108(3): 790-797, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31225694

RESUMO

Fibrin glue has been widely used as a surgical sealing and hemostatic agent. Its application is restricted due to poor tissue adhesion and low mechanical strength. To develop better tissue sealant and hemostatic agent, this study prepared the injectable hydrogels by chemically cross-linking gelatin (G) with or without hyaluronic acid (HA) in situ at a mild condition. The rheological analysis, Fourier transform infrared spectroscopy, swelling, proteolytic degradation, biocompatibility, tissue sealing, and hemostatic ability of the hydrogels were investigated. It was found that the chemical cross-linking rapidly formed in both self-crosslinking gelatin (sc-G) and gelatin/hyaluronate acid (G/HA) hydrogels. The hydrogels could be degraded by trypsin and had a desirable biocompatibility. The tissue sealing ability of the hydrogels was superior to fibrin glue. Furthermore, the G/HA hydrogel had similar hemostatic performance as fibrin glue, and was better than that of gelatin hydrogel. The results in the study indicated that the G/HA hydrogel could be used in clinic as a tissue sealant or surgical hemostat.


Assuntos
Materiais Biocompatíveis/química , Adesivo Tecidual de Fibrina/química , Gelatina/química , Ácido Hialurônico/química , Hidrogéis/química , Materiais Biocompatíveis/administração & dosagem , Materiais Biocompatíveis/efeitos adversos , Sobrevivência Celular , Reagentes de Ligações Cruzadas/química , Adesivo Tecidual de Fibrina/administração & dosagem , Adesivo Tecidual de Fibrina/efeitos adversos , Hemostasia , Hemostáticos/química , Hemostáticos/metabolismo , Humanos , Hidrogéis/administração & dosagem , Hidrogéis/efeitos adversos , Injeções , Reologia
19.
Indian J Ophthalmol ; 67(10): 1610-1616, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31546491

RESUMO

Purpose: To evaluate the visual outcome and complication profile after glued intraocular lens (IOL) in post uveitic eyes. Methods: Patients with history of uveitis who had glued IOL with 3 months antecedent quiet anterior chamber (AC) were included in this prospective observational case series. Visual acuity, slit-lamp examination, fundus evaluation, optical coherence tomography, intraocular pressure, specular count and AC inflammation were analyzed before and after glued IOL procedure. Glued IOL eyes were also compared with their fellow normal capsular bag IOL. Results: Overall 17 eyes (50.7 ± 16.1 years) were analyzed. It included 41.8%, 23.5%, and 35.29% anterior, posterior, and pan uveitis, respectively. The etiologies were tuberculosis (23.53%), toxoplasmosis (11.77%), Fuch's heterochromic cyclitis (5.88%), HLA B27 (11.77%), psoriatic arthritis (5.88%), Rheumatoid arthritis (5.8%), sarcoidosis (11.77%), herpetic kerato-uveitis (5.88%), and idiopathic (17.65%). Cataractous subluxated lens (35.3%), aphakia (23.5%), decentered IOL (23.5%) and intraoperative capsular rupture (17.6%) were the surgical indications. A significant improvement in the mean uncorrected and best corrected visual acuity (P < 0.001) was recorded. The complications were IOL pigment dispersion (47%), macular edema (41%), and epiretinal membrane (24%). There was significant rise in AC reaction on day 1 (P < 0.001) and normal AC was attained by 88.2% eyes at 6 months. AC inflammation reactivation was noted in 11.7% of eyes. Though inflammatory reactivation was similar to the normal IOL, macular edema was higher in glued IOL. Conclusion: Glued IOL can cause inflammation in uveitis eyes which can be managed medically with minimal complications.


Assuntos
Adesivo Tecidual de Fibrina/efeitos adversos , Cápsula do Cristalino/patologia , Doenças do Cristalino/complicações , Adesivos Teciduais/efeitos adversos , Uveíte/induzido quimicamente , Uveíte/complicações , Acuidade Visual/fisiologia , Adulto , Idoso , Feminino , Adesivo Tecidual de Fibrina/uso terapêutico , Humanos , Inflamação/induzido quimicamente , Pressão Intraocular , Complicações Intraoperatórias , Implante de Lente Intraocular/métodos , Masculino , Pessoa de Meia-Idade , Facoemulsificação , Estudos Prospectivos , Microscopia com Lâmpada de Fenda , Adesivos Teciduais/uso terapêutico , Tomografia de Coerência Óptica
20.
Kyobu Geka ; 72(8): 605-608, 2019 Aug.
Artigo em Japonês | MEDLINE | ID: mdl-31353353

RESUMO

We report here our experience with a case of anaphylactic shock caused by fibrin glue. A 51-year-old male underwent a thoracoscopic surgery for refractory pneumothorax under local anesthesia. Bullae were revealed, and subsequently covered with fibrin glue and a polyglycolic acid sheet. Twenty-minutes after application of the fibrin glue, sudden drop of blood pressure less than 80 mmHg and a skin rash appeared. Since the patient was not administered any other drugs prior to the reduction in blood pressure, anaphylactic shock was considered to be caused by fibrin glue. The patient recovered after the treatment by dopamine and steroid.


Assuntos
Anafilaxia , Adesivo Tecidual de Fibrina/efeitos adversos , Pneumotórax , Anafilaxia/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Toracoscopia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA