Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Chest ; 159(3): 1173-1181, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33197402

RESUMO

The clinical research we do to improve our understanding of disease and to develop new therapies has temporarily been delayed as the global health-care enterprise has focused its attention on those impacted by coronavirus disease 2019 (COVID-19). Although rates of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection are decreasing in many areas, many locations continue to have a high prevalence of infection. Nonetheless, research must continue and institutions are considering approaches to restarting non-COVID-related clinical investigation. Those restarting respiratory research must navigate the added planning challenges that take into account outcome measures that require aerosol-generating procedures. Such procedures potentially increase risk of transmission of SARS-CoV-2 to research staff, use limited personal protective equipment, and require conduct in negative-pressure rooms. One must also be prepared to address the potential for COVID-19 resurgence. With research subject and staff safety and maintenance of clinical trial data integrity as the guiding principles, here we review key considerations and suggest a step-wise approach for resuming respiratory clinical research.


Assuntos
Aerossóis/efeitos adversos , Pesquisa Biomédica , COVID-19 , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Pesquisa Biomédica/métodos , Pesquisa Biomédica/organização & administração , Pesquisa Biomédica/tendências , COVID-19/epidemiologia , COVID-19/prevenção & controle , COVID-19/transmissão , Controle de Doenças Transmissíveis/instrumentação , Controle de Doenças Transmissíveis/métodos , Humanos , Medição de Risco , SARS-CoV-2
2.
Rev. chil. anest ; 50(5): 679-684, 2021.
Artigo em Espanhol | LILACS | ID: biblio-1532563

RESUMO

The SARS-CoV-2 pandemic has changed the management protocols of the different surgical areas and practices of health institutions around the world. The countries most affected by the disease have reported an alarming impact on the number of infected and deceased by COVID-19 among health workers. Personnel specialized in airway management have a greater risk of contagion when directly exposed to the aerosolization of the virus. This leads us to consider the probability of postponing or restricting procedures due to limited resources and/or due to patient conditions that increase the risk of death, given that the usual surgical techniques generate more aerosols. This narrative review article aims to analyze the risk of contamination of professionals in laparoscopic surgery of patients infected by COVID-19, proposing strategies to minimize the risk of exposure, identifying the necessary protection measures for health professionals, providing recommendations and adaptations of both the surgical technique and the organization of the operating room according to clinical and scientific evidence.


La pandemia por el SARS-CoV-2 ha cambiado los protocolos de manejo de las distintas áreas y prácticas quirúrgicas de las instituciones de salud en el mundo. Los países con mayor afectación de la enfermedad han reportado un impacto alarmante sobre el número de infectados y fallecidos por COVID-19 entre trabajadores de la salud. El personal especializado en el manejo de la vía aérea, posee un mayor riesgo de contagio al exponerse directamente a la aerosolización del virus. Esto conlleva a considerar la probabilidad de posponer o restringir procedimientos por limitación de los recursos y/o por condiciones del paciente que aumenten el riesgo de muerte, dado que las técnicas quirúrgicas habituales generan más aerosoles. Este artículo, de revisión narrativa, pretende analizar el riesgo de contaminación de los profesionales en cirugía laparoscópica de pacientes infectados por COVID-19, proponiendo estrategias para minimizar el riesgo de exposición, identificando las medidas necesarias de protección para los profesionales de la salud, aportando recomendaciones y adaptaciones tanto de la técnica quirúrgica como de la organización del quirófano según la evidencia clínica y científica


Assuntos
Humanos , Laparoscopia , Aerossóis/efeitos adversos , COVID-19/prevenção & controle , Cuidados Pré-Operatórios , Saúde Ocupacional , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , SARS-CoV-2 , COVID-19/transmissão , Cuidados Intraoperatórios
3.
J Hosp Infect ; 106(4): 657-662, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33058941

RESUMO

BACKGROUND: The presence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in saliva has alerted health professionals to the possibility of contamination by aerosols generated in a number of procedures. The indication of preoperative mouthwash containing 1% hydrogen peroxide for reducing the viral load of SARS-CoV-2 in saliva prior to oral procedures has been significantly disseminated through several citations and influenced various dental associations in the elaboration of dental care protocols during this pandemic period, including patients admitted to hospital wards and intensive care units. AIM: To Our aim was to perform a systematic review to answer the following question: does hydrogen peroxide mouthwash (at any concentration) have a virucidal effect? METHODS: The Cochrane, LILACS, PubMed, Scopus, and Embase databases were searched by using the following key-words: 'hydrogen peroxide', 'mouthwash', 'mouth rinse', 'rinse', 'oral rinse', 'mouth bath', 'mouth wash', and 'mouth washes'. Reviews, letters to the editor, personal opinions, book chapters, case reports, congress abstracts, studies with animals and studies on mouthwash containing other compounds other than hydrogen peroxide were excluded. FINDINGS: During the initial search 1342 articles were identified on the five electronic databases. After excluding some duplicates, 976 articles remained. Only studies assessing the virucidal effect of hydrogen peroxide mouthwash were selected, regardless of publication date. CONCLUSION: After reading titles and abstracts, no article met the eligibility criteria. In conclusion, there is no scientific evidence supporting the indication of hydrogen peroxide mouthwash for control of the viral load regarding SARS-CoV-2 or any other viruses in saliva.


Assuntos
Anti-Infecciosos Locais/farmacologia , COVID-19/virologia , Peróxido de Hidrogênio/farmacologia , SARS-CoV-2/efeitos dos fármacos , Aerossóis/efeitos adversos , COVID-19/diagnóstico , COVID-19/epidemiologia , Pessoal de Saúde/educação , Humanos , Controle de Infecções/métodos , Antissépticos Bucais/farmacologia , Antissépticos Bucais/provisão & distribuição , SARS-CoV-2/genética , Saliva/virologia , Carga Viral/efeitos dos fármacos
4.
Rev Assoc Med Bras (1992) ; 66Suppl 2(Suppl 2): 55-57, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32965357

RESUMO

In the context of the COVID-19 pandemic, endoscopy services must adopt preventive measures to maintain proper functioning due to a high risk of disease contagion. Triage protocols before and after the procedure, personal protective equipment, and environmental contamination control are some of the endoscopy society's recommendations. However, the risk of infection may remain high due to poor control over the source of contamination.Using a combination of standardized supplies and accessories in a hospital, a ventilation mask adapted to be used in endoscopic procedures is proposed to reduce COVID-19 contamination.


Assuntos
Aerossóis/efeitos adversos , Infecções por Coronavirus/prevenção & controle , Transmissão de Doença Infecciosa/prevenção & controle , Endoscopia , Pandemias , Equipamento de Proteção Individual/normas , Pneumonia Viral/prevenção & controle , Betacoronavirus , COVID-19 , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/transmissão , Desenho de Equipamento , Humanos , Pneumonia Viral/epidemiologia , Pneumonia Viral/transmissão , SARS-CoV-2
5.
Rev Col Bras Cir ; 47: e20202574, 2020.
Artigo em Inglês, Português | MEDLINE | ID: mdl-32578696

RESUMO

The COVID-19 Pandemic has resulted in a high number of hospital admissions and some of those patients need ventilatory support in intensive care units. The viral pneumonia secondary to Sars-cov-2 infection may lead to acute respiratory distress syndrome (ARDS) and longer mechanical ventilation needs, resulting in a higher demand for tracheostomies. Due to the high aerosolization potential of such procedure, and the associated risks of staff and envoirenment contamination, it is necesseray to develop a specific standardization of the of the whole process involving tracheostomies. This manuscript aims to demonstrate the main steps of the standardization created by a tracheostomy team in a tertiary hospital dedicated to providing care for patients with COVID-19.


Assuntos
Infecções por Coronavirus/cirurgia , Procedimentos Cirúrgicos Eletivos/normas , Pneumonia Viral/cirurgia , Centros de Atenção Terciária/normas , Traqueostomia/normas , Aerossóis/efeitos adversos , Betacoronavirus , Brasil , COVID-19 , Infecções por Coronavirus/prevenção & controle , Humanos , Salas Cirúrgicas/normas , Duração da Cirurgia , Pandemias/prevenção & controle , Equipamento de Proteção Individual/normas , Pneumonia Viral/prevenção & controle , SARS-CoV-2
6.
Rev Col Bras Cir ; 47: e20202558, 2020 Jun 03.
Artigo em Português, Inglês | MEDLINE | ID: mdl-32578821

RESUMO

The coronavirus infection, also known as SARS-COV2, has proven to be potentially fatal, representing a major global health problem. Its spread after its origin in the city of Wuhan, China has resulted in a pandemic with the collapse of the health system in several countries, some with enormous social impact and expressive number of deaths as seen in Italy and Spain. Extreme intra and extra-hospital measures have been implemented to decrease the transmission and dissemination of the COVID-19. Regarding the surgical practice, a huge number of procedures considered non-essential or elective were cancelled and postponed until the pandemic is resolved. However, urgent and oncological procedures have been carried out. In this publication, we highlight and teach adaptations to be made with commonly used materials in laparoscopy to help prevent the spread and contamination of the healthcare team assisting surgical patients.


A infecção pelo coronavírus determinante da doença COVID-19, também conhecida como SARS-COV2 foi classificada nos últimos meses como pandemia. Essa é potencialmente fatal, representando enorme problema de saúde mundial. A disseminação, após provável origem zoonótica na cidade de Wuhan, China, resultou em colapso do sistema de saúde de diversos países, alguns com enorme impacto social e número grande de mortes descritas na Itália e Espanha. Medidas extremas intra e extra-hospitalares têm sido implementadas a fim de conter a transmissão e disseminação da COVID-19. No âmbito cirúrgico, enorme quantidade de procedimentos considerados não essenciais ou eletivos foram prorrogados ou suspensos até resolução da pandemia. No entanto, cirurgias de urgência e oncológicas não permitem que o paciente espere. Nesta publicação, sugerimos e ensinamos adaptação a ser feita com materiais de uso corriqueiro em laparoscopias para evitar a contaminação ou a disseminação entre as equipes assistenciais e os pacientes.


Assuntos
Aerossóis/efeitos adversos , Infecções por Coronavirus/prevenção & controle , Laparoscopia/métodos , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Operatórios/normas , Betacoronavirus , COVID-19 , Transmissão de Doença Infecciosa/prevenção & controle , Humanos , Período Intraoperatório , Salas Cirúrgicas/métodos , Pneumoperitônio Artificial/normas , Equipamentos de Proteção/normas , Punções/métodos , SARS-CoV-2 , Instrumentos Cirúrgicos/normas
7.
Rev. Assoc. Med. Bras. (1992, Impr.) ; Rev. Assoc. Med. Bras. (1992, Impr.);66(Suppl 2): 55-57, 2020. graf
Artigo em Inglês | Sec. Est. Saúde SP, LILACS | ID: biblio-1136388

RESUMO

SUMMARY In the context of the COVID-19 pandemic, endoscopy services must adopt preventive measures to maintain proper functioning due to a high risk of disease contagion. Triage protocols before and after the procedure, personal protective equipment, and environmental contamination control are some of the endoscopy society's recommendations. However, the risk of infection may remain high due to poor control over the source of contamination.Using a combination of standardized supplies and accessories in a hospital, a ventilation mask adapted to be used in endoscopic procedures is proposed to reduce COVID-19 contamination.


RESUMO No contexto da pandemia de COVID-19, o serviço de endoscopia deve adotar ações preventivas para manter seu funcionamento devido ao grande risco de contágio da doença. Protocolos de triagem antes e após o procedimento, equipamentos de proteção individual e controle de contaminação do ambiente fazem parte das recomendações das sociedades de endoscopia. Entretanto, o risco de infecção pode permanecer alto devido ao pouco controle da fonte de disseminação de contaminantes. A partir da combinação de suprimentos e de acessórios padronizados em um hospital, uma máscara de ventilação adaptada para ser usada em procedimentos endoscópicos é proposta com a finalidade de reduzir a contaminação por COVID-19.


Assuntos
Humanos , Pneumonia Viral/prevenção & controle , Infecções por Coronavirus/prevenção & controle , Transmissão de Doença Infecciosa/prevenção & controle , Aerossóis/efeitos adversos , Endoscopia , Pandemias , Equipamento de Proteção Individual/normas , Pneumonia Viral/transmissão , Pneumonia Viral/epidemiologia , Infecções por Coronavirus , Infecções por Coronavirus/transmissão , Infecções por Coronavirus/epidemiologia , Desenho de Equipamento , Betacoronavirus
8.
Rev. Col. Bras. Cir ; 47: e20202558, 2020. graf
Artigo em Português | LILACS | ID: biblio-1136582

RESUMO

RESUMO A infecção pelo coronavírus determinante da doença COVID-19, também conhecida como SARS-COV2 foi classificada nos últimos meses como pandemia. Essa é potencialmente fatal, representando enorme problema de saúde mundial. A disseminação, após provável origem zoonótica na cidade de Wuhan, China, resultou em colapso do sistema de saúde de diversos países, alguns com enorme impacto social e número grande de mortes descritas na Itália e Espanha. Medidas extremas intra e extra-hospitalares têm sido implementadas a fim de conter a transmissão e disseminação da COVID-19. No âmbito cirúrgico, enorme quantidade de procedimentos considerados não essenciais ou eletivos foram prorrogados ou suspensos até resolução da pandemia. No entanto, cirurgias de urgência e oncológicas não permitem que o paciente espere. Nesta publicação, sugerimos e ensinamos adaptação a ser feita com materiais de uso corriqueiro em laparoscopias para evitar a contaminação ou a disseminação entre as equipes assistenciais e os pacientes.


ABSTRACT The coronavirus infection, also known as SARS-COV2, has proven to be potentially fatal, representing a major global health problem. Its spread after its origin in the city of Wuhan, China has resulted in a pandemic with the collapse of the health system in several countries, some with enormous social impact and expressive number of deaths as seen in Italy and Spain. Extreme intra and extra-hospital measures have been implemented to decrease the transmission and dissemination of the COVID-19. Regarding the surgical practice, a huge number of procedures considered non-essential or elective were cancelled and postponed until the pandemic is resolved. However, urgent and oncological procedures have been carried out. In this publication, we highlight and teach adaptations to be made with commonly used materials in laparoscopy to help prevent the spread and contamination of the healthcare team assisting surgical patients.


Assuntos
Humanos , Pneumonia Viral/prevenção & controle , Procedimentos Cirúrgicos Operatórios/normas , Laparoscopia/métodos , Infecções por Coronavirus/prevenção & controle , Aerossóis/efeitos adversos , Pandemias/prevenção & controle , Procedimentos Cirúrgicos Robóticos/métodos , Salas Cirúrgicas/métodos , Pneumoperitônio Artificial/normas , Equipamentos de Proteção/normas , Instrumentos Cirúrgicos/normas , Punções/métodos , Transmissão de Doença Infecciosa/prevenção & controle , Betacoronavirus , SARS-CoV-2 , COVID-19 , Período Intraoperatório
9.
Rev. Col. Bras. Cir ; 47: e20202574, 2020.
Artigo em Inglês | LILACS | ID: biblio-1136603

RESUMO

ABSTRACT The COVID-19 Pandemic has resulted in a high number of hospital admissions and some of those patients need ventilatory support in intensive care units. The viral pneumonia secondary to Sars-cov-2 infection may lead to acute respiratory distress syndrome (ARDS) and longer mechanical ventilation needs, resulting in a higher demand for tracheostomies. Due to the high aerosolization potential of such procedure, and the associated risks of staff and envoirenment contamination, it is necesseray to develop a specific standardization of the of the whole process involving tracheostomies. This manuscript aims to demonstrate the main steps of the standardization created by a tracheostomy team in a tertiary hospital dedicated to providing care for patients with COVID-19.


RESUMO A pandemia da COVID-19 tem gerado um número elevado de internações hospitalares e muitos pacientes são admitidos nas unidades de terapia intensiva para suporte ventilatório invasivo. A pneumonia viral provocada pelo Sars-cov-2 pode resultar na síndrome da disfunção respiratória aguda (SDRA) e em um tempo prolongado de ventilação mecânica, gerando uma demanda maior de traqueostomias. Diante do alto potencial de aerossolização desse procedimento, com risco de contaminação da equipe e do ambiente, é necessário criar uma padronização específica de todo o processo que envolve essa cirurgia. Este artigo visa demonstrar as principais etapas dessa padronização desenvolvida por um equipe dedicada à realização de traqueostomias em um hospital terciário dedicado ao atendimento de pacientes com suspeita ou confirmação de COVID-19.


Assuntos
Humanos , Pneumonia Viral/cirurgia , Traqueostomia/normas , Procedimentos Cirúrgicos Eletivos/normas , Infecções por Coronavirus/cirurgia , Centros de Atenção Terciária/normas , Salas Cirúrgicas/normas , Pneumonia Viral/prevenção & controle , Brasil , Infecções por Coronavirus/prevenção & controle , Aerossóis/efeitos adversos , Pandemias/prevenção & controle , Duração da Cirurgia , Equipamento de Proteção Individual/normas , Betacoronavirus , SARS-CoV-2 , COVID-19
10.
Rev Saude Publica ; 47(2): 239-47, 2013 Apr.
Artigo em Inglês, Português | MEDLINE | ID: mdl-24037350

RESUMO

OBJECTIVE: To investigate the effects of fine particulate matter emitted through biomass burning on hospitalizations for respiratory diseases in children living in Manaus, Northern Brazil. METHODS: Descriptive study with ecologic time series design carried out in Manaus from 2002 to 2009. Hospital admission data were obtained from the Unified Health System database. PM2.5 levels were estimated using aerosol remote sensing through the measurement of aerosol optical depth at a wavelength of 550 nm. Statistical methods were used in the data analysis, with Pearson correlation and multiple linear regression between variables, with a 95% confidence interval. RESULTS: The region of Manaus showed low PM2.5 concentrations when compared to the Southern Amazonian region. Between August and November (dry period in the region), was when the highest mean levels of PM2.5, estimated between 18 to 23 µg/m3, and the largest number of fires were observed. For the rainy season, an average of 12 µg/m3, 66% lower than the dry season measurements (20.6 µg/m3) was observed. The highest rates of hospitalization were observed during the rainy season and April was the month with the highest levels at 2.51/1,000 children. A positive association between hospital admissions and relative humidity (R = 0.126; p-value = 0.005) was observed, while the association between admissions and PM2.5 was negative and statistically significant (R = -0.168; p-value = 0.003). The R 2 of the final model (Hospitalizations = 2.19*Humidity - 1.60*PM2.5 - 0.23*Precipitation) explained 84% of hospitalizations due to respiratory disease in children living in Manaus, considering the independent variables statistically significant (humidity, PM2.5, and precipitation). CONCLUSIONS: Hospital admissions for respiratory diseases in children in Manaus, were more related to weather conditions and in particular relative humidity, than to exposure to aerosols emitted by biomass burning in the Amazonian region.


Assuntos
Aerossóis/efeitos adversos , Aerossóis/toxicidade , Incêndios , Hospitalização/estatística & dados numéricos , Material Particulado/efeitos adversos , Material Particulado/toxicidade , Doenças Respiratórias/etiologia , Aerossóis/análise , Biomassa , Brasil/epidemiologia , Criança , Pré-Escolar , Monitoramento Ambiental , Feminino , Sistemas de Informação em Saúde , Humanos , Lactente , Modelos Lineares , Masculino , Conceitos Meteorológicos , Programas Nacionais de Saúde , Material Particulado/análise , Doenças Respiratórias/epidemiologia
11.
Rev. saúde pública ; Rev. saúde pública;47(2): 239-247, jun. 2013. tab, graf
Artigo em Português | LILACS | ID: lil-685571

RESUMO

OBJETIVO: Analisar a relação entre a exposição ao material particulado fino emitido em queimadas e as internações hospitalares por doenças respiratórias em crianças. MÉTODOS: Estudo descritivo com delineamento ecológico de séries temporais realizado em Manaus de 2002 a 2009. Os dados de internações hospitalares foram obtidos a partir do banco de dados do Sistema Único de Saúde. Os níveis de PM2.5 foram estimados por sensoriamento remoto a partir da espessura ótica de aerossóis no comprimento de onda de 550 nm. Foram utilizadas a correlação de Pearson e a regressão linear múltipla entre as variáveis com intervalo de 95% de confiança. RESULTADOS: A região de Manaus apresentou baixas concentrações de PM2.5, quando comparada com a porção sul da região Amazônica. Os meses de agosto a novembro (período seco) apresentaram os maiores níveis médios de PM2.5 (de 18 a 23 µg/m³) e os maiores números de focos de queimadas detectados. A média do PM2.5 para a estação chuvosa foi de 12 µg/m³, 66% menor que a média da estação seca, 20,6 µg/m³. As maiores taxas de internações ocorreram durante a estação chuvosa, e o mês de abril teve a maior taxa, com 2,51/1.000 crianças. Foi observada associação positiva significativa entre as internações e a umidade relativa (R = 0,126; p = 0,005), enquanto a associação entre internações com PM2.5 mostrou-se negativa e estatisticamente significativa (R = - 0,168; p = 0,003). O R² do modelo final (Internações = 2,19*Umidade - 1,60*PM2.5 - 0,23*Precipitação) explicou em 84% as internações por doenças respiratórias em ...


OBJECTIVE To investigate the effects of fine particulate matter emitted through biomass burning on hospitalizations for respiratory diseases in children living in Manaus, Northern Brazil. METHODS Descriptive study with ecologic time series design carried out in Manaus from 2002 to 2009. Hospital admission data were obtained from the Unified Health System database. PM2.5 levels were estimated using aerosol remote sensing through the measurement of aerosol optical depth at a wavelength of 550 nm. Statistical methods were used in the data analysis, with Pearson correlation and multiple linear regression between variables, with a 95% confidence interval. RESULTS The region of Manaus showed low PM2.5 concentrations when compared to the Southern Amazonian region. Between August and November (dry period in the region), was when the highest mean levels of PM2.5, estimated between 18 to 23 µg/m3, and the largest number of fires were observed. For the rainy season, an average of 12 µg/m3, 66% lower than the dry season measurements (20.6 µg/m3) was observed. The highest rates of hospitalization were observed during the rainy season and April was the month with the highest levels at 2.51/1,000 children. A positive association between hospital admissions and relative humidity (R = 0.126; p-value = 0.005) was observed, while the association between admissions and PM2.5 was negative and statistically significant (R = -0.168; p-value = 0.003). The R 2 of the final model (Hospitalizations = 2.19*Humidity - 1.60*PM2.5 - 0.23*Precipitation) explained 84% of hospitalizations due to respiratory disease in children living in Manaus, considering the independent variables statistically significant (humidity, PM2.5, and precipitation). CONCLUSIONS Hospital admissions for respiratory diseases in children in Manaus, were more related to weather conditions and in ...


Assuntos
Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Aerossóis/efeitos adversos , Aerossóis/toxicidade , Incêndios , Hospitalização/estatística & dados numéricos , Material Particulado/efeitos adversos , Material Particulado/toxicidade , Doenças Respiratórias/etiologia , Aerossóis/análise , Ecossistema Amazônico , Biomassa , Brasil/epidemiologia , Monitoramento Ambiental , Sistemas de Informação em Saúde , Modelos Lineares , Conceitos Meteorológicos , Programas Nacionais de Saúde , Material Particulado/análise , Doenças Respiratórias/epidemiologia , Incêndios Florestais
12.
Rio de Janeiro; s.n; 2012. 138 p. mapas, tab, graf.
Tese em Português | LILACS | ID: lil-663571

RESUMO

A poluição atmosférica é um problema frequente durante a estação seca na Amazônia. As queimadas na região amazônica contribuem para 70 por cento das emissões de partículas finas, aproximadamente, e apresentam efeitos diretos para o sistema respiratório, em especial para crianças. Esta tese apresenta um panorama de estudos sobre o efeito agudo da poluição atmosférica na saúde humana e aborda aspectos metodológicos sobre a análise de dados de séries temporais e indicadores de exposição para o município de Rio Branco, Amazônia Ocidental. Foram realizadas duas revisões sobre estudos de séries temporais de efeitos da poluição atmosférica na saúde humana. O primeiro fez um levantamento dos estudos realizados sobre poluição atmosférica nos locais de maior incidência de queimadas no planeta: Amazônia, Estados Unidos, Austrália e Ásia. Como resultado, foram encontradas concentração de estudos realizados na Austrália e predominância de estudos realizados com o método modelos aditivos generalizados. O segundo estudo fez uma revisão sistemática dos métodos estatísticos empregados sobre técnicas de séries temporais, entre 2000 e 2010, para estimação de efeitos à saúde humana de poluentes atmosféricos, na América Latina, especialmente no Brasil, destacando algumas limitações que afetam esse campo do conhecimento. Houve uma concentração de estudos sobre poluição atmosférica urbana em grandes centros urbanos como São Paulo, Rio de Janeiro, Santiago e Cidade do México. Aspectos metodológicos para estudos realizados em região Amazônica também foram abordados. O terceiro estudo investigou a estrutura de defasagem entre a exposição à fumaça de queimadas e o desfecho de internação hospitalar. Neste sentido, regressões de Poisson via modelos de função de transferência foram utilizados para estimar o efeito defasado do poluente. Foram encontradas associações no segundo dia de defasagem entre a exposição e o desfecho.


O quarto estudo abordou a utilização de diferentes formas de obtenção de material particulado fino como indicador de exposição à fumaça das queimadas. Riscos relativos de efeitos à saúde decorrentes da exposição ao material particulado obtido por medidas diretas e por estimativas foram comparados. Modelos aditivos generalizados foram utilizados para analisar a associação entre a demanda diária de internações por doenças respiratórias e níveis diários de material particulado obtido com dados in situ, dados de profundidade óptica de aerossóis e dados do modelo atmosférico CCATT-BRAMS, entre agosto a dezembro de 2009. Não foram encontradas associações significativas. O modelo CCATT-BRAMS apresentou medidas de PM2,5 com correlação linear de 0,63 com dados in situ, com 28 por cento dos registros superestimados. Os dados obtidos pela profundidade óptica apresentaram correlação de 0,42, subestimando em 14 por cento, aproximadamente a média diária de exposição ao PM2,5. Os melhores ajustes foram verificados para os dados modelados. Os riscos relativos obtidos pelo modelo CCATT-BRAMS apresentaram dispersões semelhantes, porém menores quando comparados aos dados in situ. Como conclusão, a tese mostra que há evidências estatísticas de efeitos agudos da exposição ao material particulado à saúde de crianças. Evidenciou-se também que os dados estimados de PM2,5 podem ser utilizados alternativamente para análise de associação da exposição ao PM2,5 e efeitos à saúde na Amazônia, ainda que os mesmos suavizem as estimativas.


Assuntos
Humanos , Recém-Nascido , Lactente , Pré-Escolar , Aerossóis/efeitos adversos , Bioestatística , Doenças Respiratórias/epidemiologia , Monitoramento Ambiental , Incêndios/estatística & dados numéricos , Material Particulado/efeitos adversos , Poluição do Ar/efeitos adversos , Ecossistema Amazônico , Exposição Ambiental/efeitos adversos , Modelos Estatísticos
13.
J Toxicol Environ Health A ; 72(15-16): 921-9, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19672760

RESUMO

A wind tunnel atomization study was conducted to measure the emission droplet size spectra for water and Glyphos (a glyphosate formulation sold in Colombia) + Cosmo-flux sprays for aerial application to control coca and poppy crops in Colombia. The droplet size spectra were measured in a wind tunnel for an Accu-Flo nozzle (with 16 size 0.085 [2.16 mm] orifices), under appropriate simulated aircraft speeds (up to 333 km/h), using a laser diffraction instrument covering a dynamic size range for droplets of 0.5 to 3,500 microm. The spray drift potential of the glyphosate was modeled using the AGDISP spray application and drift model, using input parameters representative of those occurring in Colombia for typical aerial application operations. The droplet size spectra for tank mixes containing glyphosate and Cosmo-Flux were considerably finer than water and became finer with higher aircraft speeds. The tank mix with 44% glyphosate had a D(v0.5) of 128 microm, while the value at the 4.9% glyphosate rate was 140 microm. These are classified as very fine to fine sprays. Despite being relatively fine, modeling showed that the droplets would not evaporate as rapidly as most similarly sized agricultural sprays because the nonvolatile proportion of the tank mix (active and inert adjuvant ingredients) was large. Thus, longer range drift is small and most drift that does occur will deposit relatively close to the application area. Drift will only occur downwind and, with winds of velocity less than the modeled maximum of 9 km/h, the drift distance would be substantially reduced. Spray drift potential might be additionally reduced through various practices such as the selection of nozzles, tank mix adjuvants, aircraft speeds, and spray pressures that would produce coarser sprays. Species sensitivity distributions to glyphosate were constructed for plants and amphibians. Based on modeled drift and 5th centile concentrations, appropriate no-spray buffer zones (distance from the end of the spray boom as recorded electronically +/-5%) for protection of sensitive plants were 50-120 m for coca spray scenarios and considerably lower for poppy spray scenarios. The equivalent buffer zone for amphibia was 5 m. The low toxicity of glyphosate to humans suggests that these aerial applications are not a concern for human health.


Assuntos
Aeronaves , Desfolhantes Químicos/administração & dosagem , Controle de Medicamentos e Entorpecentes/métodos , Exposição Ambiental/efeitos adversos , Glicina/análogos & derivados , Plantas Medicinais/efeitos dos fármacos , Aerossóis/efeitos adversos , Movimentos do Ar , Animais , Coca , Desfolhantes Químicos/efeitos adversos , Emulsões , Exposição Ambiental/análise , Monitoramento Ambiental/métodos , Glicina/administração & dosagem , Glicina/efeitos adversos , Humanos , Drogas Ilícitas/química , Papaver , Tamanho da Partícula , Medição de Risco , Glifosato
14.
Fisioter. pesqui ; 14(1): 36-41, jan.-abr. 2007. tab, graf
Artigo em Português | LILACS | ID: lil-450882

RESUMO

Este estudo teve como objetivo avaliar a força muscular respiratória (FMR) por meio de manovacuometria de homens e mulheres com idade entre 40 e 89 anos, verificando se há diferenças nos valores da pressão inspiratória máxima...


The purpose of the study was to assesss respiratory muscle strength (RMS) by means of manovacuometry among women and men aged 40-89, checking whether there are differences in maximal inspiratory pressure...


Assuntos
Humanos , Feminino , Aerossóis/administração & dosagem , Nebulizadores e Vaporizadores , Respiração com Pressão Positiva , Aerossóis/efeitos adversos , Pulmão , Tecnécio/administração & dosagem
15.
Rev. ciênc. farm ; 25(2): 115-118, 2004. tab
Artigo em Português | LILACS | ID: lil-418900

RESUMO

O objetivo desse trabalho foi investigar o alcance de bioaerossóis emitidos por aeradores da Estaçãdo de Tratamento de Esgoto Sanitário de Araraquara, Brasil, utilizando coliformes totais como microrganismos indicadores. A concentração de coliformes viáveis no ar foi determinada a partir de várias distâncias dos aeradores, utilizando-se impactador de ar de um estágio em Chromocult Coliform Agar (MERCK), tendo como padrão referencial a contagem obtida em outros pontos da cidade. Parâmetros meteorológicos foram determinados simultaneamente com a amostragem bacteriológica. ANOVA foi utilizada para avaliação estatística dos resultados. A concentração de coliformes totais mostrou diferença significativa em distâncias de até 100 m dos aeradores em relação ao padrão referencial. Os fatores meteorológicos não influenciaram na preservação desses microrganismos a partir de 100 m das fontes emissoras. A dispersão de bioaerossóis pelos aeradores da Estação de Tratamento de Esgoto Sanitário de Araraquara não é fonte de contaminação para áreas que circundam essa estação


Assuntos
Aeradores , Aerossóis/efeitos adversos , Aerossóis/toxicidade , Poluição do Ar/análise , Redes de Esgoto , Poluentes Ambientais
17.
In. Negrin Villavicencio, José A. Asma bronquial: aspectos básicos para un tratamiento integral según la etapa clínica. La Habana, ECIMED, 2003. , ilus.
Monografia em Espanhol | CUMED | ID: cum-38986
18.
Rev. ciênc. farm ; 22(1): 31-39, 2001. tab
Artigo em Português | LILACS | ID: lil-318747

RESUMO

Este trabalho objetivou conhecer a concentraçäo microbiana e a influência de alguns fatores ambientais na dispersäo de bioaerossóis em cômodos específicos, de uso restrito e público, do Prédio Tradicional da Faculdade de Ciências Farmacêuticas, onde situa o Departamento de Análises Clínicas, Farmácia Escola e Unidade Auxiliar. As amostragens foram realizadas utilizando-se o MAS-100, durante 2 períodos do ano, em 15 cômodos, sendo 5 laboratórios didáticos, 5 laboratórios de rotina e 5 salas de atendimento ao público. Os ambientes foram analisados em relaçäo ao tipo de climatizaçäo (natural ou artificial) e ao número de ocupantes. O tipo de climatizaçäo demonstrou näo influenciar no número de unidades formadoras de colônia por metro cúbico de ar dos diferentes ambientes. Diferenças significativas foram observadas em ambientes onde circulavam menos de 9 e 9 ou mais pessoas, independentemente do tipo de atividade desenvolvida. O fato de os próprios ocupantes serem as fontes mais prováveis de bioaerossóis em ambientes interiores estimula a instalaçäo de equipamentos eficientes que promovam a filtraçäo e renovaçäo do ar, diluindo partículas originadas dentro deles, principalmente naqueles onde há maior fluxo de indivíduos.


Assuntos
Humanos , Aerossóis/efeitos adversos , Poluentes Atmosféricos , Poluição do Ar em Ambientes Fechados/análise , Contagem de Colônia Microbiana , Setor Público , Síndrome do Edifício Doente
19.
Rev. Inst. Nac. Enfermedades Respir ; Rev. Inst. Nac. Enfermedades Respir;13(1): 18-22, ene.-mar. 2000. tab, graf
Artigo em Espanhol | LILACS | ID: lil-280329

RESUMO

Introducción: Se ha descrito que la exposición aguda a aerosoles para el cabello puede provocar obstrucción de las vías aéreas, en especial en sujetos asmáticos, pero se desconoce el efecto causado por la exposición crónica sobre la función de las vías aéreas. Métodos: Se realizó espirometría a 40 pacientes con diagnóstico establecido de asma leve a moderada expuestos regularmente a aerosoles para el cabello, y se compararon con 40 asmáticos sin exposición regular a dichos aerosoles. Resultados: Se encontró un mayor grado de obstrucción al flujo aéreo en pacientes asmáticos expuestos a aerosoles para el cabello (FEV1/FVC 63.1 ñ 7.2 por ciento, x ñ DE), en comparación con los asmáticos no expuestos (80.3 ñ 13.2 por ciento, p < 10-8), que ocurrió por igual en mujeres y hombres. Evaluada por frecuencias, el 82.5 por ciento de los expuestos y el 37.5 por ciento de los no expuestos presentaban obstrucción (definida por FEV1/FVC < 80 por ciento), con una razón de momios de 7.86 e intervalos de confianza al 95 por ciento de 2.53 a 25.87. Aunque siempre con mayor obstrucción, el grupo expuesto no mostró deterioro acelerado de la relación FEV1/FVC a lo largo de la edad. Conclusiones: La exposición regular al aerosol para el cabello en pacientes asmáticos incrementó significativamente la obstrucción al flujo aéreo (aunque no aceleró la caída del FEV1/FVC a largo plazo), por lo que su uso debería evitarse o restringirse al mínimo en pacientes con asma.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Aerossóis/efeitos adversos , Obstrução das Vias Respiratórias , Asma/patologia , Exposição a Produtos Químicos , Espirometria
20.
Rev. Ateneo Argent. Odontol ; 37(1): 38-40, ene.-jun. 1998. ilus
Artigo em Espanhol | LILACS | ID: lil-241271

RESUMO

El presente trabajo trata de contribuir al conocimiento y aplicación de normas de bioseguridad en la práctica odontológica, desarrollando un modelo didáctico en un quirófano y demostrando la producción y flujo de gotas y aerosoles durante las prácticas que implican el uso de instrumental rotatorio. Se revistieron segmentos de paredes y camilla con papel negro; se procedió a hacer funcionar un instrumento rotatorio de baja velocidad, goteando sobre la fresa isotiocianato de fluoresceína, bajo luz U.V. Se tomaron fotografías bajo luz U.V. en las que se observa un fino puntillado de fluorescencia verde. Se demuestra la producción de aerosoles que en la extrapolación a la práctica odontológica representarían microgotas de saliva contaminadas, potencialmente patógenas. Se transcriben los riesgos legales


Assuntos
Aerossóis/efeitos adversos , Consultórios Odontológicos/normas , Poluição Ambiental/prevenção & controle , Controle de Infecções Dentárias/métodos , Equipamentos Odontológicos de Alta Rotação , Infecções por HIV/prevenção & controle , Modelos Educacionais , Salas Cirúrgicas/normas , Medidas de Segurança/provisão & distribuição , Raios Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA