Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 148
Filtrar
1.
J Magn Reson Imaging ; 59(5): 1777-1784, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37515309

RESUMO

BACKGROUND: Although biopsy is often entailed for managing patients with kidney allograft dysfunction, it is associated with potential complications of severe hemorrhage. Arterial spin labeling (ASL) is a non-invasive technique that assesses tissue perfusion. PURPOSE: To assess the utility of ASL for the discrimination of patients with post-transplant allograft dysfunction who do not need biopsy from those who need. STUDY TYPE: Prospective. SUBJECTS: Forty-six patients (34 males/12 females, aged 38.8 ± 9.5 years) with kidney allograft dysfunction, including 31 in which biopsy directly lead to changes in management (NECESSARY group) and 15 in which clinical management did not alter after biopsy (UNNECESSARY group). FIELD STRENGTH/SEQUENCE: 3.0 T and 3D fast-spin echo sequence. ASSESSMENT: All patients underwent both ASL scan and biopsies. The serum creatinine, proteinuria, pathologic results, and cortical ASL readings were obtained and compared between the two groups. STATISTICAL ANALYSES: Chi-square test, independent student t-test, Mann-Whitney U test, receiver-operating characteristic curve. A two-tailed P < 0.05 denoted statistical significance. RESULTS: The NECESSARY group presented with significantly elevated serum creatinine as compared with the UNNECESSARY group (1.87 ± 0.56 mg/dL vs. 1.31 ± 0.37 mg/dL). The acute composite score was significantly higher in the NECESSARY group than that in the UNNECESSARY group (7 [4-8] vs. 1 [0-2]). Cortical ASL in the NECESSARY group was significantly decreased as compared with the UNNECESSARY group (108.06 [69.96-134.92] mL/min/100 g vs. 153.48 [113.19-160.37] mL/min/100 g). Serum creatinine differentiated UNNCESSARY group from the NECESSARY group with an area under the curve (AUC) and specificity of 0.79 and 54.84%, respectively. By comparison, the cortical ASL yielded an AUC of 0.75 and a specificity of 70.97%. Notably, the specificity was increased to 90.30% by combined use of serum creatinine and cortical ASL. DATA CONCLUSION: The combined use of ASL and serum creatinine yielded a high specificity for selecting patients who may not need allograft biopsy. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 3.


Assuntos
Rim , Imageamento por Ressonância Magnética , Masculino , Feminino , Humanos , Marcadores de Spin , Creatinina , Estudos Prospectivos , Rim/diagnóstico por imagem , Aloenxertos/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
5.
Br J Radiol ; 96(1143): 20220722, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36607279

RESUMO

OBJECTIVES: To investigate the value of DTI in differentiation of renal allograft rejection from well-functioning stable allograft, using fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values. METHODS: In this prospective study, 22 transplant recipients with well-functioning stable allograft (group A) and 20 patients with renal allograft rejection (group B + C) were recruited over a period of 19 months from January 2018 to July 2019. DTI-MRI was performed in all the patients, and FA and ADC values were measured in cortical and medullary regions of the transplanted kidney. On biopsy, graft rejection was classified as acute (group B) (n = 7) and chronic graft rejection (group C) (n = 13) based on the BANNF scoring system. Statistical analysis was performed using STATA v.14.0. RESULTS: Statistically significant difference between group A and group B + C was noted for cortical (p < 0.001), and medullary (p = 0.003) FA values, and cortical (p = 0.020), and medullary (p = 0.046) ADC values. Cortical(p < 0.001) and Medullary(p = 0.020) FA values showed statistically significant difference between group A and group C, and cortical FA value(p = 0.012) also showed statistically significant difference between group B and group C. AUC (to differentiate between renal allograft rejection and well-functioning stable allograft) for cortical, and medullary FA values and cortical and medullary ADC values were 0.853(p < 0.001), 0.757(p = 0.004), 0.709(p = 0.021) and 0.736(p = 0.009), respectively. CONCLUSION AND ADVANCES IN KNOWLEDGE: DTI is a promising functional MRI technique for the non-invasive assessment of renal allograft function. Diffusion parameters, such as FA and ADC values, can be useful in the differentiation of renal allograft rejection from well-functioning stable allograft.


Assuntos
Imagem de Tensor de Difusão , Transplante de Rim , Humanos , Imagem de Tensor de Difusão/métodos , Estudos Prospectivos , Rim/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Anisotropia , Aloenxertos/diagnóstico por imagem
6.
Abdom Radiol (NY) ; 48(2): 608-620, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36441198

RESUMO

PURPOSE: Atherosclerosis affects clinical outcomes in the setting of major surgery. Here we aimed to investigate the prognostic role of visceral aortic (VAC), extended visceral aortic (VAC+), and celiac artery calcification (CAC) in the assessment of short- and long-term outcomes following deceased donor orthotopic liver transplantation (OLT) in a western European cohort. METHODS: We retrospectively analyzed the data of 281 consecutive recipients who underwent OLT at a German university medical center (05/2010-03/2020). The parameters VAC, VAC+, or CAC were evaluated by preoperative computed tomography-based calcium quantification according to the Agatston score. RESULTS: Significant VAC or CAC were associated with impaired postoperative renal function (p = 0.0016; p = 0.0211). Patients with VAC suffered more frequently from early allograft dysfunction (EAD) (38 vs 26%, p = 0.031), while CAC was associated with higher estimated procedural costs (p = 0.049). In the multivariate logistic regression analysis, VAC was identified as an independent predictor of EAD (2.387 OR, 1.290-4.418 CI, p = 0.006). Concerning long-term graft and patient survival, no significant difference was found, even though patients with calcification showed a tendency towards lower 5-year survival compared to those without (VAC: 65 vs 73%, p = 0.217; CAC: 52 vs 72%, p = 0.105). VAC+ failed to provide an additional prognostic value compared to VAC. CONCLUSION: This is the first clinical report to show the prognostic role of VAC/CAC in the setting of deceased donor OLT with a particular value in the perioperative phase. Further studies are warranted to validate these findings. CT computed tomography, OLT orthotopic liver transplantation.


Assuntos
Calcinose , Doença da Artéria Coronariana , Transplante de Fígado , Humanos , Artéria Celíaca/diagnóstico por imagem , Estudos Retrospectivos , Doadores Vivos , Calcinose/complicações , Aorta , Rim/fisiologia , Aloenxertos/diagnóstico por imagem , Fatores de Risco
7.
Pediatr Pulmonol ; 58(1): 213-221, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36200536

RESUMO

INTRODUCTION: Chronic lung allograft dysfunction (CLAD) continues to negatively impact the survival of pediatric lung transplant (LTx) recipients. Current consensus guidelines are adult-focused. We sought to examine CLAD detection and monitoring practices at pediatric LTx programs. METHODS: We conducted a survey among the International Pediatric Lung Transplant Collaborative. Questions consisted of practitioner's experience, LTx program demographics, and querying tests used for CLAD surveillance and detection. Investigations queried included: chest x-ray (CXR), chest computed tomography (CT), lung magnetic resonance imaging (MRI), ventilation/perfusion scanning, conventional pulmonary function testing (PFT), multiple breath washout (MBW), infant/preschool PFT, bronchoalveolar lavage, transbronchial biopsies (TBBx), or other tissue sampling techniques. Preferences for certain modalities over others were questioned based on a five-point Likert scale. RESULTS: Twenty-four of 25 programs responded. Chest CT and CXR are used generally for both CLAD surveillance and detection. No programs use lung MRI clinically, it may have some utility in the future. While all centers use conventional PFT, MBW, and infant/preschool PFT are used in one-fifth and one-third of centers, respectively. While the majority of programs use TBBx, only 41.7% would obtain a diagnosis based on tissue histopathology over noninvasive techniques if CLAD is suspected. Utilization of biomarkers is still limited. CONCLUSIONS: Our results indicate continued use of conventional PFT along with chest CT and less so CXR for CLAD detection and monitoring in the large majority of centers. Infant/preschool PFT and novel methods such as MBW are used in a few centers only. Respondents agreed there is a timely need for pediatric consensus guidelines on CLAD detection and monitoring.


Assuntos
Transplante de Pulmão , Adulto , Humanos , Criança , Pré-Escolar , Estudos Retrospectivos , Pulmão/diagnóstico por imagem , Transplante Homólogo , Aloenxertos/diagnóstico por imagem
8.
Curr Cardiol Rep ; 24(12): 1865-1871, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36279035

RESUMO

PURPOSE OF REVIEW: Cardiac allograft vasculopathy (CAV) is a late-occurring complication of heart transplantation significantly limiting overall graft survival. In the last few years, evidence has been growing about the use of positron emission tomography (PET) myocardial perfusion imaging with integrated myocardial blood flow (MBF) quantification in heart transplant recipients. RECENT FINDINGS: Multiple studies have demonstrated that PET MBF assessment can be utilized to establish the diagnosis of CAV noninvasively and can be employed for prognostication. PET MBF quantification has also helped to define the link between transplant rejection and CAV. In addition, limited data suggests that PET MBF quantification can be used in heart transplant patients for serial monitoring of CAV. PET myocardial perfusion imaging integrating MBF quantification shows great promise for the evaluation of CAV with good diagnostic and prognostic performance.


Assuntos
Doença da Artéria Coronariana , Transplante de Coração , Imagem de Perfusão do Miocárdio , Humanos , Imagem de Perfusão do Miocárdio/métodos , Angiografia Coronária/métodos , Tomografia por Emissão de Pósitrons/métodos , Transplante de Coração/métodos , Aloenxertos/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/etiologia
9.
Clin Hemorheol Microcirc ; 82(4): 303-311, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36057814

RESUMO

BACKGROUND: Conventional ultrasound (US), which include gray scale US and Doppler US, is the first-line imaging modality for the evaluation of renal allograft; however, conventional US indicators have limitations. OBJECTIVE: To explore the application value of shear-wave elastography (SWE) combined with monochrome superb microvascular imaging (mSMI) in renal allograft chronic rejection (CR). METHODS: From November 2021 to February 2022 in the Lanzhou University Second Hospital, the US features of 54 patients with renal allograft were retrospectively analyzed. Patients were categorized into two groups: stable group(n = 44) and CR group(n = 10), with clinical diagnosis as reference standard. The vascular index (VI) on mSMI and parenchymal stiffness were measured in the middle cortex of all renal allografts and receiver operating characteristic (ROC) curves were drawn to evaluate the feasibility of differentiation. Statistically significant US features and biochemical indicators such as creatinine were scored, and the results of the scores were analyzed by ROC curve. RESULTS: The VI on mSMI of the stable group (49.5±2.0) was significantly greater than that of the CR group (33.8±5.9) (P = 0.028). There was a statistically significant difference in parenchymal stiffness between stable group (16.2kPa±1.2) and CR group (33.9kPa±6.6) (P = 0.027). The sensitivity was 90% and specificity was 81.8% of the scores in the differentiation of stable group from CR group (cut-off value, 2; P = 0.000). CONCLUSION: SWE combined with mSMI may help differentiate stable renal allograft from renal allograft CR and have the potential application value in the diagnosis of renal allograft CR.


Assuntos
Técnicas de Imagem por Elasticidade , Transplante de Rim , Humanos , Técnicas de Imagem por Elasticidade/métodos , Estudos Retrospectivos , Rim/diagnóstico por imagem , Aloenxertos/diagnóstico por imagem , Sensibilidade e Especificidade
10.
Clin Hemorheol Microcirc ; 82(1): 75-83, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35662110

RESUMO

BACKGROUND: B-Mode and Doppler ultrasound are standard diagnostic techniques for early postoperative monitoring and long-term follow-up of kidney transplants. In certain cases, contrast-enhanced ultrasound (CEUS) is used to clarify unclear Doppler findings. OBJECTIVE: To investigate the diagnostic performance of CEUS in the workup of renal allograft pathologies. METHODS: A systematic search for CEUS examinations of renal transplants conducted in our department between 2008 and 2020 was performed using the following inclusion criteria: i) patient age ≥18 years and ii) confirmation of diagnosis by biopsy and histopathology, imaging follow-up by CEUS, contrast-enhanced computed tomography (ceCT), contrast-enhanced magnetic resonance imaging (ceMRI), or angiography, or intraoperative findings. Exclusion criteria were: i) CEUS performed in the setting of a study and ii) CEUS for other indications than dedicated renal transplant examination. Statistical analysis was performed separately for subgroups with different indications (focal vs non-focal). RESULTS: Overall, 78 patients were included in the statistical analysis, which revealed high sensitivity (92.2%, 95% -confidence interval [CI] 81.5-96.9%) and high specificity (88.9%, 95% -CI 71.9-96.1%) of CEUS. CONCLUSIONS: The high diagnostic performance demonstrated here and the superficial location of kidney allografts advocate the additional use of CEUS in the follow-up of renal transplant recipients.


Assuntos
Meios de Contraste , Transplante de Rim , Adolescente , Aloenxertos/diagnóstico por imagem , Humanos , Rim/diagnóstico por imagem , Rim/patologia , Transplante de Rim/métodos , Centros de Atenção Terciária , Ultrassonografia/métodos
11.
Circ Cardiovasc Interv ; 15(5): e011656, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35580200

RESUMO

BACKGROUND: Coronary angiography is the gold standard for cardiac allograft vasculopathy (CAV) diagnosis, but it usually detects the disease at an advanced stage. We investigated the role of quantitative flow ratio (QFR), a noninvasive tool to identify potentially flow-limiting lesions, in predicting CAV development in heart transplant recipients. METHODS: Consecutive heart transplant recipients with no evidence of angiographic CAV at baseline coronary angiography were retrospectively included between January 2010 and December 2015, and QFR computation was performed. The relationship between vessel QFR and the occurrence of angiographic vessel-related CAV (≥50% stenosis) was assessed. RESULTS: One hundred forty-three patients were included and QFR computation was feasible in 241 vessels. The median value of QFR at baseline coronary angiography was 0.98 (interquartile range, 0.94-1.00). During a median follow-up of 6.0 years (interquartile range, 4.6-7.8 years), vessel-related CAV occurred in 25 (10.4%) vessels. Receiver-operating characteristic curve analysis identified a QFR best cutoff of ≤0.95 (area under the curve, 0.81 [95% CI, 0.71-0.90]; P<0.001). QFR≤0.95 was associated with an increased risk of vessel-related CAV (adjusted hazard ratio, 20.87 [95% CI, 5.35-81.43]; P<0.001). In an exploratory analysis, QFR≤0.95 in at least 2 vessels was associated with higher incidence of cardiovascular death or late graft dysfunction (71.4% in recipients with 2-3 vessels affected versus 5.1% in recipients with 0-1 vessels affected, P<0.001). CONCLUSIONS: In a cohort of heart transplant recipients, QFR computation at baseline coronary angiography may be a safe and reliable tool to predict vessel-related CAV and clinical outcomes at long-term follow-up.


Assuntos
Doença da Artéria Coronariana , Transplante de Coração , Aloenxertos/diagnóstico por imagem , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/etiologia , Vasos Coronários/diagnóstico por imagem , Transplante de Coração/efeitos adversos , Humanos , Valor Preditivo dos Testes , Estudos Retrospectivos , Resultado do Tratamento
12.
Transplant Rev (Orlando) ; 36(2): 100692, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35364360

RESUMO

Pancreas transplantation (PT) allows improved glycaemic control for patients with complicated type 1 diabetes mellitus and is most commonly performed simultaneously with a renal transplant. Imaging modalities are critical for the assessment of pancreatic graft dysfunction, as clinical assessment and hyperglycaemia lack robust sensitivity for the transplant clinician. Biopsy represents the most conclusive standard of PT graft assessment but is challenging due to its invasive nature and the potential morbidity associated with the procedure. Innovative imaging technologies offer the opportunity to apply these modalities to improve PT outcomes while using non-invasive technologies to provide a diagnostic sensitivity that traditionally only biopsies can provide. Early graft dysfunction has traditionally been investigated with Computed tomography (CT) and ultrasound (US) scans. We explore adjuncts to these modalities including the application of contrast enhanced ultrasound (CEUS) for routine post-operative graft assessment to inform post-operative treatment strategies. There is currently a dearth of imaging modalities to reliably monitor long term graft function, but the use of innovative functional imaging techniques and how they can be applied to PT is discussed. Perfusion CT and glucose stimulated magnetic resonance imaging (MRI) to detect whole organ function are examined. In addition, early phase developments in beta-cell specific imaging methods to quantify beta-cell mass longitudinally are described. The clinical applications of such tools including Mn2+-enhanced MR and GLP-1R targeted PET/CT are reviewed and may demonstrate opportunities to provide the transplant clinician with greater information to support improved patient care.


Assuntos
Transplante de Rim , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Aloenxertos/diagnóstico por imagem , Humanos , Transplante de Rim/métodos , Pâncreas/patologia , Ultrassonografia/métodos
13.
Kidney Int ; 101(4): 804-813, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35031327

RESUMO

Kidney cortical interstitial fibrosis is highly predictive of kidney prognosis and is currently assessed by evaluation of a biopsy. Diffusion-weighted magnetic resonance imaging is a promising non-invasive tool to evaluate kidney fibrosis. We recently adapted diffusion-weighted imaging sequence for discrimination between the kidney cortex and medulla and found that the cortico-medullary difference in apparent diffusion coefficient (ΔADC) correlated with histological interstitial fibrosis. Here, we assessed whether ΔADC as measured with diffusion-weighted magnetic resonance imaging is predictive of kidney function decline and dialysis initiation in chronic kidney disease (CKD) and patients with a kidney allograft in a prospective study encompassing 197 patients. We measured ΔADC in 43 patients with CKD (estimated GFR (eGFR) 55ml/min/1.73m2) and 154 patients with a kidney allograft (eGFR 53ml/min/1.73m2). Patients underwent a kidney biopsy and diffusion-weighted magnetic resonance imaging within one week of biopsy; median follow-up of 2.2 years with measured laboratory parameters. The primary outcome was a rapid decline of kidney function (eGFR decline over 30% or dialysis initiation) during follow up. Significantly, patients with a negative ΔADC had 5.4 times more risk of rapid decline of kidney function or dialysis (95% confidence interval: 2.29-12.58). After correction for kidney function at baseline and proteinuria, low ADC still predicted significant kidney function loss with a hazard ratio of 4.62 (95% confidence interval 1.56-13.67) independent of baseline age, sex, eGFR and proteinuria. Thus, low ΔADC can be a predictor of kidney function decline and dialysis initiation in patients with native kidney disease or kidney allograft, independent of baseline kidney function and proteinuria.


Assuntos
Rim , Insuficiência Renal Crônica , Aloenxertos/diagnóstico por imagem , Aloenxertos/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Fibrose , Taxa de Filtração Glomerular , Humanos , Rim/patologia , Masculino , Estudos Prospectivos , Proteinúria/diagnóstico por imagem , Proteinúria/etiologia , Proteinúria/patologia , Insuficiência Renal Crônica/diagnóstico por imagem , Insuficiência Renal Crônica/patologia , Insuficiência Renal Crônica/cirurgia
14.
Sci Rep ; 12(1): 828, 2022 01 17.
Artigo em Inglês | MEDLINE | ID: mdl-35039571

RESUMO

The study aimed to discriminate renal allografts with impaired function by measuring cortical renal blood flow (cRBF) using magnetic resonance imaging arterial spin labelling (ASL-MRI) in paediatric and young adult patients. We included 18 subjects and performed ASL-MRI on 1.5 T MRI to calculate cRBF on parameter maps. cRBF was correlated to calculated glomerular filtration rate (GFR) and compared between patient groups with good (GFR ≥ 60 mL/min/1.73 m2) and impaired allograft function (GFR < 60 mL/min/1.73 m2). Mean cRBF in patients with good allograft function was significantly higher than in patients with impaired allograft function (219.89 ± 57.24 mL/min/100 g vs. 146.22 ± 41.84 mL/min/100 g, p < 0.008), showing a highly significant correlation with GFR in all subjects (r = 0.75, p < 0.0001). Also, the diffusion-weighted imaging (DWI-MRI) apparent diffusion coefficient (ADC) and Doppler measurements of peak-systolic and end-diastolic velocities and the resistive index (PS, ED, RI) were performed and both methods showed no significant difference between groups. ADC implied no correlation with GFR (r = 0.198, p = 0.464), while PS indicated moderate correlation to GFR (r = 0.48, p < 0.05), and PS and ED moderate correlation to cRBF (r = 0.58, p < 0.05, r = 0.56, p < 0.05, respectively). Cortical perfusion as non-invasively measured by ASL-MRI differs between patients with good and impaired allograft function and correlates significantly with its function.


Assuntos
Aloenxertos/diagnóstico por imagem , Aloenxertos/fisiopatologia , Imagem de Difusão por Ressonância Magnética/métodos , Falência Renal Crônica/fisiopatologia , Transplante de Rim , Imageamento por Ressonância Magnética/métodos , Circulação Renal/fisiologia , Transplante Homólogo , Adolescente , Adulto , Criança , Diástole , Feminino , Taxa de Filtração Glomerular , Humanos , Córtex Renal/irrigação sanguínea , Córtex Renal/diagnóstico por imagem , Falência Renal Crônica/cirurgia , Masculino , Sístole , Adulto Jovem
15.
Nephrol Dial Transplant ; 37(12): 2581-2590, 2022 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-35020923

RESUMO

BACKGROUND: Reliable diagnosis of the cause of renal allograft dysfunction is of clinical importance. The aim of this study is to develop a hybrid deep-learning approach for determining acute rejection (AR), chronic allograft nephropathy (CAN) and renal function in kidney-allografted patients by multimodality integration. METHODS: Clinical and magnetic resonance imaging (MRI) data of 252 kidney-allografted patients who underwent post-transplantation MRI between December 2014 and November 2019 were retrospectively collected. An end-to-end convolutional neural network, namely RtNet, was designed to discriminate between AR, CAN and stable renal allograft recipient (SR), and secondarily, to predict the impaired renal graft function [estimated glomerular filtration rate (eGFR) ≤50 mL/min/1.73 m2]. Specially, clinical variables and MRI radiomics features were integrated into the RtNet, resulting in a hybrid network (RtNet+). The performance of the conventional radiomics model RtRad, RtNet and RtNet+ was compared to test the effect of multimodality interaction. RESULTS: Out of 252 patients, AR, CAN and SR was diagnosed in 20/252 (7.9%), 92/252 (36.5%) and 140/252 (55.6%) patients, respectively. Of all MRI sequences, T2-weighted imaging and diffusion-weighted imaging with stretched exponential analysis showed better performance than other sequences. On pairwise comparison of resulting prediction models, RtNet+ produced significantly higher macro-area-under-curve (macro-AUC) (0.733 versus 0.745; P = 0.047) than RtNet in discriminating between AR, CAN and SR. RtNet+ performed similarly to the RtNet (macro-AUC, 0.762 versus 0.756; P > 0.05) in discriminating between eGFR ≤50 mL/min/1.73 m2 and >50 mL/min/1.73 m2. With decision curve analysis, adding RtRad and RtNet to clinical variables resulted in more net benefits in diagnostic performance. CONCLUSIONS: Our study revealed that the proposed RtNet+ model owned a stable performance in revealing the cause of renal allograft dysfunction, and thus might offer important references for individualized diagnostics and treatment strategy.


Assuntos
Glomerulosclerose Segmentar e Focal , Transplante de Rim , Imageamento por Ressonância Magnética Multiparamétrica , Humanos , Transplante de Rim/efeitos adversos , Rejeição de Enxerto/diagnóstico por imagem , Rejeição de Enxerto/etiologia , Estudos Retrospectivos , Redes Neurais de Computação , Aloenxertos/diagnóstico por imagem
16.
Curr Probl Cardiol ; 47(8): 101103, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35016989

RESUMO

Cardiac allograft vasculopathy (CAV) is the leading cause of long-term graft dysfunction in patients with heart transplantation and is linked with significant morbidity and mortality. Currently, the gold standard for diagnosing CAV is coronary imaging with intravascular ultrasound during traditional invasive coronary angiography. Invasive imaging, however, carries increased procedural risk and expense to patients in addition to requiring an experienced interventionalist. With the improvements in non-invasive cardiac imaging modalities such as transthoracic echocardiography, computed tomography, magnetic resonance imaging and positron emission tomography, an alternative non-invasive imaging approach for the early detection of CAV may be feasible. In this systematic review, we explored the literature to investigate the utility of non-invasive imaging in diagnosis of CAV in >3000 patients across 49 studies. We also discuss the strengths and weaknesses for each imaging modality. Overall, all 4 imaging modalities show good to excellent accuracy for identifying CAV with significant variations across studies. Majority of the studies compared non-invasive imaging with invasive coronary angiography without intravascular imaging. In summary, non-invasive imaging modalities offer an alternative approach to invasive coronary imaging for CAV. Future studies should investigate longitudinal non-invasive protocols in low-risk patients after heart transplantation.


Assuntos
Doença da Artéria Coronariana , Transplante de Coração , Aloenxertos/irrigação sanguínea , Aloenxertos/diagnóstico por imagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/etiologia , Ecocardiografia , Transplante de Coração/efeitos adversos , Humanos
17.
Heart Fail Rev ; 27(4): 1235-1246, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34383194

RESUMO

Cardiac allograft vasculopathy (CAV) is an obliterative and diffuse form of vasculopathy affecting almost 50% of patients after 10 years from heart transplant and represents the most common cause of long-term cardiovascular mortality among heart transplant recipients. The gold standard diagnostic technique is still invasive coronary angiography, which however holds potential for complications, especially contrast-related kidney injury and procedure-related vascular lesions. Non-invasive and contrast-sparing imaging techniques have been advocated and investigated over the past decades, in order to identify those that could replace coronary angiography or at least reach comparable accuracy in CAV detection. In addition, they could help the clinician in defining optimal timing for invasive testing. This review attempts to examine the currently available non-invasive imaging techniques that may be used in the follow-up of heart transplant patients, spanning from echocardiography to nuclear imaging, cardiac magnetic resonance and cardiac computed tomography angiography, weighting their advantages and disadvantages.


Assuntos
Doença da Artéria Coronariana , Transplante de Coração , Aloenxertos/diagnóstico por imagem , Aloenxertos/patologia , Angiografia Coronária/efeitos adversos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/etiologia , Transplante de Coração/efeitos adversos , Humanos , Tomografia Computadorizada por Raios X/efeitos adversos , Tomografia Computadorizada por Raios X/métodos
18.
Curr Probl Diagn Radiol ; 51(5): 779-786, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34836722

RESUMO

Meniscal allograft transplantation may be indicated in a subset of patients with high-grade meniscectomy or irreparable meniscal injury and persistent knee pain that is resistant to conservative management. Meniscal allograft transplantation has demonstrated good to excellent results in short-term to midterm follow-up studies and satisfactory outcomes in long-term studies. The goals of this article are to review the indications, preoperative imaging assessment, surgical techniques, and postoperative assessment of uncomplicated and complicated meniscal allograft transplants.


Assuntos
Articulação do Joelho , Meniscos Tibiais , Aloenxertos/diagnóstico por imagem , Seguimentos , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Meniscos Tibiais/cirurgia , Meniscos Tibiais/transplante , Transplante Homólogo
19.
Kathmandu Univ Med J (KUMJ) ; 20(78): 124-127, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-37017153

RESUMO

Background Non-invasive evaluation tool for allograft kidney is important to predict chronic allograft dysfunction as it can be alternative to the invasive biopsy which is prone to so many complications. Sonoelastography can assess the stiffness of the allograft renal parenchyma, which is prone to undergo interstitial fibrosis. Objective To correlate sonoelastography with histopathology findings in the renal allografts. Method Sonoelastography was done in 60 renal allograft recipients prior to their biopsy for various indications. Estimated glomerular filtration rate (eGFR) of the patient were also obtained. Histopathology reports were collected to determine Banff score of interstitial fibrosis. Descriptive measurements (Mean ± standard deviation, Frequencies, Proportions) were calculated. Correlations among the variables were measured using Pearson's correlation, independent sample t-test, and ANOVA. Result The mean strain index (SI) was lower in higher grades of fibrosis. There was significant difference in mean SI (F=18.264; df= 2,57; p < 0.001) among the histological grades of fibrosis. Also a significant difference in SI among mild and moderate (S.E. 0.27, p value < 0.001), mild and severe (S.E. 0.213, p value < 0.001) as well as moderate and severe fibrosis (S.E. 0.244, p value < 0.001) was seen. Significant correlation of eGFR with SI (p < 0.001) was also seen. Conclusion Strain index, measured with sonoelastography, significantly correlated with different grades of tissue fibrosis. Thus it can be used as alternative method for evaluation of renal allograft patients to avoid complications of biopsy.


Assuntos
Técnicas de Imagem por Elasticidade , Transplante de Rim , Humanos , Transplante de Rim/efeitos adversos , Técnicas de Imagem por Elasticidade/métodos , Rim/diagnóstico por imagem , Fibrose , Aloenxertos/diagnóstico por imagem , Aloenxertos/patologia
20.
Int J Mol Sci ; 22(19)2021 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-34638994

RESUMO

The authors present their contribution to the improvement of methods suitable for the detection of the freezing and thawing damage of cells of cryopreserved venous grafts used for lower limb revascularization procedures. They studied the post-thaw viability of cells of the wall of cryopreserved venous grafts (CVG) immediately after thawing and after 24 and 48 h culture at +37 °C in two groups of six CVG selected randomly for slow thawing in the refrigerator and rapid thawing in a water bath at +37 °C. The grafts were collected from multi-organ and tissue brain-dead donors, cryopreserved, and stored in a liquid nitrogen vapor phase for five years. The viability was assessed from tissue slices obtained by perpendicular and longitudinal cuts of the thawed graft samples using in situ staining with fluorescence vital dyes. The mean and median immediate post-thaw viability values above 70% were found in using both thawing protocols and both types of cutting. The statistically significant decline in viability after the 48-h culture was observed only when using the slow thawing protocol and perpendicular cutting. The possible explanation might be the "solution effect damage" during slow thawing, which caused a gentle reduction in the graft cellularity. The possible influence of this phenomenon on the immunogenicity of CVG should be the subject of further investigations.


Assuntos
Aloenxertos/diagnóstico por imagem , Criopreservação/métodos , Veia Femoral/diagnóstico por imagem , Corantes Fluorescentes , Congelamento , Imagem Óptica/métodos , Veia Safena/diagnóstico por imagem , Aloenxertos/efeitos dos fármacos , Apoptose/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Crioprotetores/farmacologia , Dimetil Sulfóxido/farmacologia , Veia Femoral/efeitos dos fármacos , Humanos , Microscopia Confocal/métodos , Veia Safena/efeitos dos fármacos , Doadores de Tecidos , Enxerto Vascular/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...