1.
Artigo em Inglês | MEDLINE | ID: mdl-36001063

RESUMO

Sucrose acetate isobutyrate SAIB (E444) is a mixture produced by the esterification of sucrose with acetic anhydride and isobutyric anhydride. It is a food additive that is used as an emulsifier in soft drinks. It is difficult to analyse SAIB quantitatively because there are 256 synthesisable structures in the mixture. This study developed an analytical method for SAIB using gas chromatography-flame ionization detection (GC-FID). The pre-treatment of SAIB in soft drinks was performed using a liquid-liquid extraction method, which demonstrated a recovery rate of 107.8 ± 7.2%. In the GC-FID analysis of SAIB, numerous peaks were observed in the chromatogram, and the content of SAIB was calculated as the sum of these peak areas. A series of analytical methods were validated according to International Conference for Harmonization (ICH) guidelines. Accordingly, the applicability of the developed analytical method was confirmed for both domestic and imported soft drinks distributed in Korea. Additionally, in the linoleic acid emulsion, SAIB exhibited better lipid oxidation stability than the natural antioxidant α-tocopherol and had similar efficacy to the synthetic antioxidant butylated hydroxytoluene (BHT). Although SAIB has excellent lipid oxidation stability, it must be used within legal standards according to consumer demand to reduce the use of synthetic materials in processed foods. The validated GC-FID analytical method will enable subsequent monitoring of the distributed products.


Assuntos
Antioxidantes , Hidroxitolueno Butilado , Anidridos Acéticos/análise , Antioxidantes/análise , Hidroxitolueno Butilado/análise , Bebidas Gaseificadas/análise , Cromatografia Gasosa , Emulsões , Ionização de Chama , Aditivos Alimentares/análise , Ácido Linoleico , Sacarose/análogos & derivados , alfa-Tocoferol/análise
2.
Molecules ; 25(8)2020 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-32316669

RESUMO

Sensitive real-time detection of vapors produced by the precursors, reagents and solvents used in the illegal drugs manufacture represents a priority nowadays. Acetic anhydride (AA) is the key chemical used as acetylation agent in producing the illegal drugs heroin and methaqualone. This study was directed towards quick detection and quantification of AA in air, using two fast and very sensitive analytical techniques: photoionization detection (PID) and ion mobility spectrometry (IMS). Results obtained indicated that both PID and IMS can sense AA at ultra-trace levels in air, but while PID produces a non-selective response, IMS offers richer information. Ion mobility spectrometric response in the positive ion mode presented one product ion, at reduced ion mobility K0 of 1.89 cm2 V-1 s-1 (almost overlapped with positive reactant ion peak), while in the negative ion mode two well separated product ions, with K0 of 1.90 and 1.71 cm2 V-1 s-1, were noticed. Our study showed that by using a portable, commercial IMS system (model Mini IMS, I.U.T. GmbH Berlin) AA can be easily measured at concentrations of 0.05 ppmv (0.2 mg m-3) in negative ion mode. Best selectivity and sensitivity of the IMS response were therefore achieved in the negative operation mode.


Assuntos
Anidridos Acéticos/análise , Técnicas Biossensoriais , Drogas Ilícitas/análise , Drogas Ilícitas/química , Espectrometria de Mobilidade Iônica , Oligoelementos/análise , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/normas , Espectrometria de Mobilidade Iônica/instrumentação , Espectrometria de Mobilidade Iônica/métodos , Espectrometria de Mobilidade Iônica/normas , Reprodutibilidade dos Testes
3.
Food Chem ; 220: 198-207, 2017 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-27855890

RESUMO

Although pre-column derivatization with n-propylamine and acetic anhydride combined with the gas chromatograph was a useful method for the analysis of monosaccharide composition, failure often occurs because of lack of detail information on the mechanism as well as the operating key point in derivatization process. In this study, the key points in the derivatization (lactonization time, the amount of n-propylamine and acetic anhydride) were investigated and optimized to improve the method. Under the optimal conditions, the derivatives of seven neutral monosaccharides and two uronic acids were simultaneouly obtained, after which they were well separated and detected by GC. It was also found that all derivatives of monosaccharides were stable even stored for 20days. The linearity, sensitivity, precision, reproducibility and recovery rate of the improved method were evaluated. Thereafter, five polysaccharide samples from different sources were analyzed to validate the improved method.


Assuntos
Cromatografia Gasosa/métodos , Monossacarídeos/análise , Ácidos Urônicos/análise , Anidridos Acéticos/análise , Limite de Detecção , Reprodutibilidade dos Testes
4.
Biol Pharm Bull ; 39(6): 903-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27251491

RESUMO

Cigarette smoke contains many harmful chemicals that contribute to the pathogenesis of smoking-related diseases such as chronic obstructive pulmonary disease, cancer, and cardiovascular disease. Many studies have been done to identify cytotoxic chemicals in cigarette smoke and elucidate the onset of the above-mentioned diseases caused by smoking. However, definitive mechanisms for cigarette smoke toxicity remain unknown. As candidates for cytotoxic chemicals, we have recently found methyl vinyl ketone (MVK) and acetic anhydride in nicotine/tar-free cigarette smoke extract (CSE) using L-tyrosine (Tyr), an amino acid with highly reactive hydroxyl group. The presence of MVK and acetic anhydride in CSE was confirmed by gas chromatography-mass spectrometry (GC/MS). We also found new reaction products formed in B16-BL6 mouse melanoma (B16-BL6) cells treated with CSE using LC/MS. These were identified as glutathione (GSH) conjugates of α,ß-unsaturated carbonyl compounds, MVK, crotonaldehyde (CA), and acrolein (ACR), by the mass value and product ion spectra of these new products. ACR and MVK are type-2 alkenes, which are well known as electron acceptors and form Michael-type adducts to nucleophilic side chain of amino acids on peptides. These α,ß-unsaturated carbonyl compounds may have a key role in CSE-induced cell death.


Assuntos
Anidridos Acéticos/análise , Butanonas/análise , Fumaça/análise , Tirosina/química , Anidridos Acéticos/toxicidade , Animais , Butanonas/toxicidade , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Cromatografia Líquida , Cromatografia Gasosa-Espectrometria de Massas , Glutationa/química , Glutationa/metabolismo , Espectrometria de Massas , Melanoma Experimental , Camundongos , Fumaça/efeitos adversos , Produtos do Tabaco
6.
Appl Occup Environ Hyg ; 17(11): 765-7, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12419104

RESUMO

Respiratory effects associated with welding fumes have been manifested in welders as occupational asthma. Previous studies have concerned mainly the effects of metal fume exposure, although it has also been suggested that asthma may develop as a result of exposure to contaminants generated from painted metals. To determine whether welding fumes contain irritating and sensitizing anhydrides, air samples were collected during the repair welding of forest harvesters, which were painted with chlorinated polyester paint. Samples were collected with an assembly of a spiral glass trap inserted between a filter holder with a Teflon filter and a Tenax sampling tube. Sample analyses were with GC-MS and GC-ECD. Sensitizing anhydrides released from the paint into the air were primarily chlorendic anhydride (<2-44 microg/m(3)) and phthalic anhydride (11-21 microg/m(3)). Hydrogen chloride (HCl) and hexachlorocyclopentadiene were also found. Airborne HCl was measured with Dräger tubes. Since paint films are electrical insulators, the film around the welding seam was removed before arc welding. Removal of paint with an abrasive wheel caused the least exposure to HCl (<0.5 ppm) in contrast to burning with a gas fuel torch, (HCl approximately 5 ppm). HCl exposure was the highest (<0.5-20 ppm) during welding. It is recommended that dry paint coating be removed from an area around the seam with an abrasive wheel, not by burning, before welding.


Assuntos
Anidridos Acéticos/análise , Poluentes Ocupacionais do Ar/análise , Substâncias Perigosas/análise , Exposição Ocupacional/análise , Saúde Ocupacional , Soldagem , Anidridos Acéticos/efeitos adversos , Adulto , Poluentes Ocupacionais do Ar/efeitos adversos , Alérgenos/efeitos adversos , Monitoramento Ambiental , Feminino , Substâncias Perigosas/efeitos adversos , Humanos , Masculino , Concentração Máxima Permitida , Pessoa de Meia-Idade , Exposição Ocupacional/efeitos adversos , Medição de Risco
7.
J Pharm Biomed Anal ; 30(3): 859-67, 2002 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-12367712

RESUMO

Three simple and accurate methods are presented for determination of Cetirizine, Fexofenadine, Loratadine and Acrivastine in pure form and commercial dosage forms. The first method is based on the reaction of the above cited drugs with bromocresol purple dye to form ion-pair complex extractable with chloroform and subsequently measured spectrophotometrically. Secondly, eosin gives with these drugs ion-pair complex, measurable directly without extraction both spectrophotometrically and spectrofluorimetrically. The last method involves the base-catalysed condensation of mixed anhydrides of organic acids (citric acid/acetic anhydride) where as the tertiary amino group in the above-cited drugs acts as the basic catalyst. The product of condensation is measured spectrophotometrically. All the reaction conditions for the proposed methods have been studied.


Assuntos
Antagonistas dos Receptores Histamínicos H1/análise , Anidridos Acéticos/análise , Púrpura de Bromocresol , Ácido Cítrico/análise , Formas de Dosagem , Amarelo de Eosina-(YS) , Antagonistas dos Receptores Histamínicos H1/administração & dosagem , Espectrometria de Fluorescência/métodos , Espectrofotometria/métodos
8.
J Chromatogr A ; 868(1): 41-50, 2000 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-10677078

RESUMO

Few chromatography methods have been reported for the determination of anhydrides in mixtures or as mixed anhydrides. The potential reactivity of anhydrides with water and other common eluent components complicates possible schemes for separation and analysis. By optimizing variables that affect hydrolysis, including the stationary phase, conditions can be found to successfully analyze anhydrides as reactive as acetic anhydride. The corresponding acids can be determined at the same time. The effect of the stationary phase on anhydride hydrolysis rates may prove to be a sensitive means of probing stationary phase chemistry.


Assuntos
Anidridos/análise , Cromatografia Líquida de Alta Pressão/métodos , Ácidos Graxos/análise , Anidridos Acéticos/análise , Hidrólise
9.
J Chromatogr B Biomed Appl ; 661(1): 47-53, 1994 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-7866551

RESUMO

After ingestion of an unknown dose of detajmium, a 14-year-old female collapsed with asystolia. Resuscitation efforts were not successful. A medicolegal autopsy was carried out, and blood, liver and gastric content were extracted and analyzed by gas chromatography-mass spectrometry (GC-MS). After derivatization with acetic anhydride, detajmium and twelve of its derivatives and metabolites were identified. The main metabolic pathways include hydroxylation and subsequent O-methylation of the indol ring, and oxidation as well as reduction of the C-21 hydroxyl function. Cleavage of the N-alkyl side-chain is a further, possibly non-enzymatic degradation pathway. Artifact formation induced by acetylation included dehydratation of the hydroxyl function of C-21 and the N-alkyl side-chain. The detajmium concentration in blood of the decreased was determined by high-performance liquid chromatography with fluorimetric detection (12 micrograms/ml).


Assuntos
Ajmalina/análogos & derivados , Antiarrítmicos/intoxicação , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Conteúdo Gastrointestinal/química , Fígado/química , Anidridos Acéticos/análise , Adolescente , Ajmalina/análise , Ajmalina/sangue , Ajmalina/intoxicação , Antiarrítmicos/análise , Antiarrítmicos/sangue , Autopsia , Feminino , Humanos
10.
Am Ind Hyg Assoc J ; 46(5): 236-43, 1985 May.
Artigo em Inglês | MEDLINE | ID: mdl-4003274

RESUMO

A versatile reagent-coated solid sorbent tube has been developed for monitoring airborne reactive chemicals--including acetic anhydride (AcAn), chloroacetyl chloride (CAC), and isocyanatoethyl methacrylate (IEM). The monitoring procedures involve simultaneous collection and derivatization of these chemicals using the reagent 1-(2-pyridyl)piperazine. Following tube/pump sampling, the derivatives are solvent desorbed and analyzed by high performance thin layer chromatography (HPTLC). HPTLC offers high sample throughout chromatographic analyses. The methods are designed to provide accurate time-weighted-average (TWA) and short-term excursion measurements. The reactivity of anhydrides, acid halides, and isocyanates preclude long-term collection without derivatization. Formation of the derivative immediately stabilizes the molecules allowing retention on the solid sorbent. In addition, the derivative allows good chromatography and provides high detection sensitivity. The recoveries for acetic anhydride, chloracetyl chloride and isocyanatoethyl methacrylate are 97.5, 95.2 and 85.0%, respectively. Validation also included the evaluation of humidity effects, storage effects, and potential interferences.


Assuntos
Acetatos/análise , Anidridos Acéticos/análise , Acrilatos/análise , Poluentes Atmosféricos/análise , Isocianatos , Metacrilatos/análise , Cromatografia em Camada Fina , Umidade , Métodos
11.
Am Ind Hyg Assoc J ; 40(9): 803-8, 1979 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-517439

RESUMO

This paper describes the development of a new method for monitoring acetic anhydride in the presence of acetic acid in the occupational environment. The method consisted of collecting airborne acetic anhydride on a solid sorbent, desorbing it with acetone and analyzing it by gas chromatography. During the development of this method various parameters such as selection of column, selection of solid sorbent, selection of desorber solvent, effects of humidity, flow rate, total sample volume, desorption efficiency, and shelf-life of samples were studied. Interference from methyl acetate, water, formic acid, and acetic acid was also tested with the determination of acetic anhydride.


Assuntos
Acetatos/análise , Anidridos Acéticos/análise , Poluentes Ocupacionais do Ar/análise , Poluentes Atmosféricos/análise , Adsorção/métodos , Cromatografia Gasosa/métodos , Métodos
SELEÇÃO DE REFERÊNCIAS