Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Mol Sci ; 22(7)2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33915912

RESUMO

The aim of this study was to develop magnetic molecularly imprinted nano-conjugate sorbent for effective dispersive solid phase extraction of antazoline (ANT) and its metabolite, hydroxyantazoline (ANT-OH) in analytical method employing liquid chromatography coupled with mass spectrometry method. The core-shell material was characterized in terms of adsorption properties, morphology and structure. The heterogeneous population of adsorption sites towards ANT-OH was characterized by two Kd and two Bmax values: Kd (1) = 0.319 µg L-1 and Bmax (1) = 0.240 µg g-1, and Kd (2) = 34.6 µg L-1 and Bmax (2) = 5.82 µg g-1. The elemental composition of magnetic sorbent was as follows: 17.55, 37.33, 9.14, 34.94 wt% for Si, C, Fe and O, respectively. The extraction protocol was optimized, and the obtained results were explained using theoretical analysis. Finally, the analytical method was validated prior to application to pharmacokinetic study in which the ANT was administrated intravenously to three healthy volunteers. The results prove that the novel sorbent could be useful in extraction of ANT and ANT-OH from human plasma and that the analytical strategy could be a versatile tool to explain a potential and pharmacological activity of ANT and ANT-OH.


Assuntos
Antazolina/sangue , Polímeros Molecularmente Impressos/química , Nanoconjugados/química , Adsorção , Adulto , Antazolina/farmacocinética , Voluntários Saudáveis , Humanos , Masculino , Extração em Fase Sólida
2.
J Pharm Biomed Anal ; 128: 294-301, 2016 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-27289300

RESUMO

Cloud-point extraction (CPE) is attracting increasing interest in a number of analytical fields, including bioanalysis, as it provides a simple, safe and environmentally-friendly sample preparation technique. However, there are only few reports on the application of this extraction technique in liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) analysis. In this study, CPE was used for the isolation of antazoline from human plasma. To date, only one method of antazoline isolation from plasma exists-liquid-liquid extraction (LLE). The aim of this study was to prove the compatibility of CPE and LC-ESI-MS/MS and the applicability of CPE to the determination of antazoline in spiked human plasma and clinical samples. Antazoline was isolated from human plasma using Triton X-114 as a surfactant. Xylometazoline was used as an internal standard. NaOH concentration, temperature and Triton X-114 concentration were optimized. The absolute matrix effect was carefully investigated. All validation experiments met international acceptance criteria and no significant relative matrix effect was observed. The compatibility of CPE and LC-ESI-MS/MS was confirmed using clinical plasma samples. The determination of antazoline concentration in human plasma in the range 10-2500ngmL(-1) by the CPE method led to results which are equivalent to those obtained by the widely used liquid-liquid extraction method.


Assuntos
Antazolina/sangue , Antagonistas dos Receptores Histamínicos H1/sangue , Antazolina/farmacocinética , Calibragem , Cromatografia Líquida de Alta Pressão , Antagonistas dos Receptores Histamínicos H1/farmacocinética , Humanos , Extração Líquido-Líquido , Octoxinol , Polietilenoglicóis , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray , Tensoativos
3.
J Pharm Biomed Anal ; 123: 113-9, 2016 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-26895496

RESUMO

Antazoline is a first-generation antihistaminic agent with antiarrhythmic quinidine-like properties. In some countries, it is widely used for termination of cardiac arrhythmias, especially atrial fibrillation (AF). However, no human pharmacokinetic studies have been conducted with intravenous antazoline. The aim of our study was to develop and validate a novel liquid chromatography/tandem mass spectrometry (LC-MS/MS) method for the determination of antazoline in human plasma: the ELEPHANT-I [ELEctrophysiological, pharmacokinetic and hemodynamic effects of PHenazolinum (ANTazoline mesylate)] human pharmacokinetic study. Antazoline was extracted from plasma using liquid-liquid extraction. The concentration of the analyte was measured by LC-MS/MS with xylometazoline as an internal standard. The method was validated for linearity, precision, accuracy, stability (freeze/thaw stability, stability in autosampler, short and long term stability), dilution integrity and matrix effect. The analyzed validation criteria were fulfilled. The method was applied to a pharmacokinetic study involving 10 healthy volunteers. Following a single intravenous dose of antazoline mesylate (100 mg), the plasma concentration profile showed a relative fast elimination with a terminal elimination half-life of 2.29 h. A relatively high volume of distribution was observed (Vss=315 L). The values of mean residence time (MRT∞), area under the curve (AUC∞) and clearance were 3.45 h, 0.91 mg h L(-1) and 80.5 L h(-1), respectively. One volunteer showed significant differences in pharmacokinetic parameters. In conclusion, the proposed new LC-MS/MS method was successfully used for the first time for the determination of antazoline in human plasma.


Assuntos
Antazolina/sangue , Antazolina/farmacocinética , Cromatografia Líquida/métodos , Mesilatos/sangue , Mesilatos/farmacocinética , Plasma/química , Espectrometria de Massas em Tandem/métodos , Adulto , Antazolina/química , Estabilidade de Medicamentos , Feminino , Meia-Vida , Hemodinâmica/fisiologia , Humanos , Extração Líquido-Líquido/métodos , Masculino , Mesilatos/química , Reprodutibilidade dos Testes
4.
Artigo em Inglês | MEDLINE | ID: mdl-23669609

RESUMO

In order to evaluate the pharmacokinetics characteristic of antazoline hydrochloride in Beagle dogs, a sensitive and specific HPLC method was developed and validated using phenacetin as the internal standard (IS). The analyte and the IS were extracted from dog plasma by ethyl acetate under the basic condition. The analyte was separated by a C18 column and detected with a variable wavelength UV-detector. The mobile phase consisted of methanol-5mmolL(-1) tetrabutyl ammonium bromide (45:55, v/v) containing 0.5% glacial acetic acid in a flow rate of 1.0mLmin(-1). Standard calibration graph for antazoline was linear over a curve range of 20-1600ngmL(-1) (R>0.99) and the lower limit of quantification was 20ngmL(-1) using a plasma sample of 500µL. The intra- and inter-day precision values were less than 14.3% relative standard deviation (RSD). The intra-day assay accuracy was in the range of 98.1-100.6% and the inter-day assay accuracy in the range of 99.2-101.1%. The extraction recoveries were on the average of 88.4% for antazoline and 76.8% for IS. Plasma samples were stable at least for 1 month at -20°C. This method was successfully applied to pharmacokinetics study of antazoline after intravenous administration to Beagle dogs.


Assuntos
Antazolina/sangue , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia de Fase Reversa/métodos , Animais , Antazolina/farmacocinética , Cães , Feminino , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...