Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Rev. esp. enferm. dig ; 115(1): 10-15, 2023. ilus, tab
Artigo em Inglês | IBECS | ID: ibc-214667

RESUMO

Introduction: The use of premedication for upper gastrointestinal endoscopy (UGE) is not widely established in western countries. The primary aim of the study was to compare gastric visibility according to the total visibility score (TVS). The secondary aim was to assess complications, diagnostic yield, endoscopic procedure time, sedation dose and patient satisfaction. Methods: A single center prospective cohort study was performed of consecutive adults undergoing an UGE in the afternoon working shift. After completing enrolment in the control group, patients were administered 200 mg simethicone and 500 mg N-acetylcysteine diluted in 100 ml of water >15 minutes before the procedure. All procedures were recorded and a single, blinded endoscopist evaluated the TVS after recruitment of both cohorts. Patient satisfaction was evaluated using the Spanish translation of the American Society of Gastrointestinal Endoscopy satisfaction questionnaire. Results: 205 patients were included in the study, 103 females (50.2%) with a median age of 54.8-years (IQR: 41.2-65.2). 104 were enrolled to the control group and 101 to the intervention group. Patients receiving premedication presented a higher rate of adequate (74.3% vs 45.2; difference 95% CI: 16,3-41,9%, p<0.001) and excellent gastric visibility (23.8% vs 7.7%; difference 95% CI: 6,3-25,8%, p=0.002). Propofol dose was similar, although the median procedure time was lower in the group of no intervention [5 (IQR: 4-7) vs 6 minutes (IQR: 5-7); p=0.03]. Procedure related adverse events were similar, except that patient without premedication experienced more nausea episodes. Major and minor endoscopic findings and the satisfaction questionnaire showed no differences between both groups. Conclusion: Patients receiving premedication with simethicone and N-acetylcysteine had a better gastric visibility score, without any increase in adverse events or affecting the patients’ satisfaction (AU)


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Endoscopia Gastrointestinal/métodos , Pré-Medicação , Simeticone/administração & dosagem , Antiespumantes/administração & dosagem , Acetilcisteína/administração & dosagem , Estudos Prospectivos , Estudos de Coortes
2.
Benef Microbes ; 12(3): 249-257, 2021 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-33765904

RESUMO

The aim of the study was to determine effects of administration of simethicone and a multi-strain synbiotic on the crying behaviour of colicky babies. The study design consisted of an open-label, two parallel treatment group study involving 87 infants aged 3-6 weeks with infantile colic (defined as crying episodes lasting 3 or more hours per day and occurring at least 3 days per week within 3 weeks prior to enrolment) randomly, unequally [1:1.5] assigned to receive simethicone (n=33) or a multi-strain synbiotic (n=54) orally for 4 weeks. The multi-strain synbiotic contained Lactobacillus acidophilus LA-14, Lacticaseibacillus casei R0215, Lacticaseibacillus paracasei Lp-115, Lacticaseibacillus rhamnosus GG, Ligilactobacillus salivarius Ls-33, Bifidobacterium lactis Bl-04, Bifidobacterium bifidum R0071, Bifidobacterium longum R0175 and fructooligosaccharides). Primary outcome measures were the responder rates (effect ≥50% reduction from baseline) of the measures 'crying days last 3 weeks', 'average evening crying duration last 3 weeks' and 'reduction of average number of crying phases per day last three weeks' at the end of treatment. The study is registered at ClinicalTrials.gov under NCT04487834. Significantly higher responder rates (effect ≥50% reduction from baseline) of the multi-strain synbiotic compared to simethicone were found for the measures 'crying days last 3 weeks' (72% vs 18%, P<0.0001) and 'average evening crying duration last 3 weeks' (85% vs 39%, P=0.0001). No significant difference was found for the measure 'reduction of average number of crying phases per day last three weeks' (50% vs 42%, P=0.4852). No adverse effects were reported for the two treatment groups. Based on these results, the multi-strain synbiotic can be considered as an interesting therapeutic possibility for the treatment of infantile colic, worthwhile to be investigated further in non-clinical and clinical studies.


Assuntos
Bactérias , Cólica/terapia , Simeticone/administração & dosagem , Simbióticos/administração & dosagem , Antiespumantes/administração & dosagem , Bactérias/classificação , Choro/fisiologia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Resultado do Tratamento
3.
Contraception ; 101(3): 178-182, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31927026

RESUMO

OBJECTIVE: To examine the effect of simethicone on reducing operative difficulty associated with bowel interference during minilaparotomy for postpartum modified Pomeroy partial salpingectomy. STUDY DESIGN: We enrolled 20-45-year-old women planning the procedure from March 2018 to February 2019. We randomized participants to chew simethicone 160 mg with water 50 mL 2-8 h before surgery or no treatment. The participants were not blinded; however, surgeons, care providers, and outcome assessors were blinded to the study allocation. We measured surgeon-rated operative difficulty using a 10-cm visual analog scale that represented the difficulty perceived to be resulting from bowel interference. Secondary outcomes included operative time and intraoperative and postoperative complications. RESULTS: We enrolled 60 women in each group; baseline characteristics and procedural profiles were comparable. Women in the intervention group used simethicone a median of 157 min (interquartile range 127-192) before the procedure. Surgeons rated the procedure difficulty score as 4.8 in the simethicone group and 4.5 in the control group (p = 0.57). Operative time in the two groups were 26 and 24 min, respectively (p = 0.14). We found no difference in intraoperative adverse events including blood loss and mesosalpinx tear, postoperative morbidities, hospital stay, and patient-rated satisfaction scores. CONCLUSION: Preprocedural simethicone has no demonstrable benefit in reducing operative difficulty caused by bowel interference during minilaparotomy for postpartum tubal sterilization. IMPLICATIONS: Preprocedural simethicone as given in this study did not result in reduced bowel interference and improved procedure difficulty. Further research examining simethicone in this setting would not be worthwhile as clinically meaningful benefit is unlikely.


Assuntos
Antiespumantes/administração & dosagem , Laparotomia/efeitos adversos , Salpingectomia/métodos , Simeticone/administração & dosagem , Esterilização Tubária/métodos , Adulto , Feminino , Motilidade Gastrointestinal , Humanos , Pessoa de Meia-Idade , Duração da Cirurgia , Satisfação do Paciente , Complicações Pós-Operatórias/etiologia , Período Pós-Operatório , Método Simples-Cego , Adulto Jovem
4.
Indian J Gastroenterol ; 38(3): 268-272, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31317387

RESUMO

Simethicone is an antifoaming agent frequently added to endoscopic rinse solutions but has recently been implicated as a risk factor for transmission of infections due to the formation of simethicone deposits within scope channels. Since the build-up of residue is likely dose-related, the smallest effective dose of simethicone should be used but there are no data available on the effective dose. Thus, we conducted a dose-finding study in an "in vitro bubble model" to determine the appropriate simethicone dose. Six 100-mL test tubes were filled with a 1% (v/v) solution of kitchen detergent (Fairy®, Procter & Gamble, London, England) in water for irrigation (Baxter®, Sydney, Australia). One test tube served as the control, while different doses of simethicone (Infacol®, Nice Pak, Melbourne, Australia) were added to the other five tubes (0.02, 0.2, 2.0, 20, and 200 mg/100 mL). Oxygen was streamed for 30 s into the test tubes at a rate of 2 L/min. After 10 s, photographs were taken and the visible bubbles were semi-quantitatively rated by independent assessors blinded to the dosing of simethicone. Simethicone at doses of 2 mg/100 mL had no appreciable antifoaming effect, whereas concentrations ≥ 20 mg/100 mL were sufficient to suppress bubble formation. This is substantially lower compared with frequently used doses of up to 200 mg/100 mL. Subsequently, we tested the lower simethicone dose with previously used higher doses, in 1475 and 1340 patients, respectively. We found it to have no impact on polyp detection with a rate of 56.7% (54.2-59.3% [95% CI]) at the lower dose and 56.5% (53.8-59.1% [95% CI]) at the higher dose.


Assuntos
Antiespumantes/administração & dosagem , Pólipos do Colo/diagnóstico , Colonoscopia/métodos , Simeticone/administração & dosagem , Adulto , Idoso , Detergentes , Feminino , Humanos , Técnicas In Vitro , Masculino , Pessoa de Meia-Idade , Água
5.
Endoscopy ; 51(8): 775-794, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31295746

RESUMO

ESGE recommends a low fiber diet on the day preceding colonoscopy.Strong recommendation, moderate quality evidence.ESGE recommends the use of enhanced instructions for bowel preparation.Strong recommendation, moderate quality evidence.ESGE suggests adding oral simethicone to bowel preparation.Weak recommendation, moderate quality evidence.ESGE recommends split-dose bowel preparation for elective colonoscopy.Strong recommendation, high quality evidence.ESGE recommends, for patients undergoing afternoon colonoscopy, a same-day bowel preparation as an acceptable alternative to split dosing.Strong recommendation, high quality evidence.ESGE recommends to start the last dose of bowel preparation within 5 hours of colonoscopy, and to complete it at least 2 hours before the beginning of the procedure.Strong recommendation, moderate quality evidence.ESGE recommends the use of high volume or low volume PEG-based regimens as well as that of non-PEG-based agents that have been clinically validated for routine bowel preparation. In patients at risk for hydroelectrolyte disturbances, the choice of laxative should be individualized.Strong recommendation, moderate quality evidence.


Assuntos
Catárticos/administração & dosagem , Colonoscopia/métodos , Administração Oral , Antiespumantes/administração & dosagem , Fibras na Dieta/administração & dosagem , Humanos , Educação de Pacientes como Assunto , Simeticone/administração & dosagem
6.
Dig Dis Sci ; 64(9): 2607-2613, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30977077

RESUMO

BACKGROUND: Colonic bubbles obscure the colonic mucosa during colonoscopy following bowel preparation with polyethylene glycol plus ascorbic acid (PEG-Asc). Simethicone is used to enhance visualization during colonoscopy. We aimed to determine the optimal timing of simethicone addition to improve bowel preparation using PEG-Asc. METHODS: This prospective, randomized study enrolled patients undergoing elective colonoscopy from April 2017 to January 2018. They were randomly assigned to one of the following three groups: PEG-Asc only (control) or simethicone addition in the morning on the day of colonoscopy (PEG-S1) or in the evening of the day prior to colonoscopy (PEG-S2). The primary outcome was the quality of colon cleansing, and the secondary outcomes were the adenoma detection rate (ADR), polyp detection rate (PDR), and diminutive (≤ 5 mm) ADR. RESULTS: In total, 240 patients were randomly allocated to the three groups; six patients were withdrawn. Of the 234 patients evaluated, 78, 79, and 77 were allocated to the control, PEG-S1, and PEG-S2 groups, respectively. The bubble scores of all colonic segments were lowest in the PEG-S2 group. There was no significant difference in ADR or PDR among the three groups. However, the diminutive ADR was significantly higher in the PEG-S2 group compared to the other two groups (control 5.1% vs. PEG-S1 8.9% vs. PEG-S2 20.8%; P = 0.009). CONCLUSION: Addition of simethicone to PEG-Asc at the optimal time prevents the formation of air bubbles and so improves the quality of bowel preparation, especially enhancing diminutive ADR.


Assuntos
Adenoma/diagnóstico por imagem , Antiespumantes/administração & dosagem , Pólipos do Colo/diagnóstico por imagem , Colonoscopia , Neoplasias Colorretais/diagnóstico por imagem , Simeticone/administração & dosagem , Adenoma/patologia , Adulto , Idoso , Ácido Ascórbico , Catárticos , Neoplasias Colorretais/patologia , Método Duplo-Cego , Esquema de Medicação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polietilenoglicóis , Estudos Prospectivos
7.
Am J Infect Control ; 47(6): 666-670, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30922624

RESUMO

BACKGROUND: Current methods for reprocessing flexible endoscopes do not consistently eliminate organic soil. The off-label use of simethicone as a defoaming agent may contribute to reprocessing failures, and endoscope manufacturers have cautioned against its use. METHODS: We sought evidence of simethicone use by interviewing hospital personnel, conducting audits, inspecting endoscopes, and conducting tests. RESULTS: Researchers examined 69 fully reprocessed endoscopes in 4 hospitals. Microbial cultures were positive for ≥50% of endoscopes. Researchers observed cloudy, shimmery fluid resembling simethicone inside channels and under a duodenoscope elevator mechanism. Crystallized white fragments were observed protruding from a gastroscope water jet outlet. Oily, sticky residue was found on endoscopes, and a 3-dimensional mass was found inside an endoscopic ultrasound endoscope. Hospital personnel reported the use of simethicone, cooking oil and silicone sprays, and tissue glue during endoscopy. DISCUSSION: The off-label use of defoaming agents, lubricants, and tissue glue is common and many endoscopists consider these products essential. Our findings suggest these substances are not removed during reprocessing and may impact reprocessing effectiveness. CONCLUSIONS: Infection preventionists should determine whether these products are used in their institutions and evaluate methods for removing them. New policies may be needed to support procedural success and effective endoscope reprocessing.


Assuntos
Adesivos/administração & dosagem , Antiespumantes/administração & dosagem , Endoscópios/microbiologia , Endoscopia/métodos , Contaminação de Equipamentos/estatística & dados numéricos , Lubrificantes/administração & dosagem , Simeticone/administração & dosagem , Descontaminação/métodos , Emolientes , Pessoal de Saúde , Hospitais , Humanos , Entrevistas como Assunto , Estudos Prospectivos
8.
J Gastroenterol Hepatol ; 34(2): 314-320, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30069899

RESUMO

BACKGROUND AND AIM: Although several randomized controlled trials (RCTs) have reported that supplemental simethicone (SIM) can improve bowel preparation based on polyethylene glycol, there is no consensus as to whether SIM can ultimately increase the adenoma detection rate (ADR) during colonoscopy. A meta-analysis was performed to assess the effect of SIM on ADR during colonoscopy. METHODS: Databases including PubMed, EMBASE, and the Cochrane Library were searched to find relevant RCTs. RCTs evaluating the effect of pre-procedure SIM on the ADR during colonoscopy were finally included, and fixed effect models were applied. RESULTS: Six trials involving 1855 patients were finally included. The present meta-analysis suggested that the ADR during colonoscopy was significantly increased by supplemental SIM (27.9% vs 23.3%, P = 0.02), with a relative risk of 1.20 (95% confidence interval 1.03-1.39). Subgroup analysis suggested that supplemental SIM may be more useful to improve ADR during colonoscopy in endoscopic centers with low baseline ADR. CONCLUSIONS: Supplemental SIM for bowel preparation based on polyethylene glycol is useful to improve the ADR during colonoscopy.


Assuntos
Adenoma/patologia , Antiespumantes/administração & dosagem , Catárticos/administração & dosagem , Colonoscopia , Neoplasias Colorretais/patologia , Simeticone/administração & dosagem , Irrigação Terapêutica/métodos , Adulto , Antiespumantes/efeitos adversos , Catárticos/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Ensaios Clínicos Controlados Aleatórios como Assunto , Simeticone/efeitos adversos , Irrigação Terapêutica/efeitos adversos
9.
J Gastroenterol Hepatol ; 34(5): 830-836, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30311262

RESUMO

BACKGROUND AND AIM: Simethicone is an anti-foaming agent commonly used during colonoscopy. Although several randomized trials have shown that oral simethicone in the bowel preparation regimen may improve bowel cleanness, whether it improves adenoma detection rate (ADR) or polyp detection rate remains undetermined. The aim of this study was to determine if oral simethicone in bowel preparation regimen before colonoscopy improves the ADR. METHODS: A comprehensive literature review was conducted using PubMed, SDOL, Cochrane Library, and ProQuest databases through December 2017. Randomized controlled trials that compared bowel preparation regimens with simethicone versus those without it were included. Effect estimates from each study were extracted and underwent meta-analysis using appropriate models. The primary outcomes were ADR and polyp detection rate, and secondary outcomes included bowel preparation, bubble score, and withdrawal time. RESULTS: Twelve published randomized controlled studies with 6003 participants were included for meta-analysis. There was no difference in the overall ADR (pooled risk ratio = 1.06, 95% confidence interval = 0.91-1.24) and right-side ADR (risk ratio = 1.50, 95% confidence interval = 0.82-2.75) between the groups with or without simethicone. However, the addition of simethicone improved adenoma detected per patient (2.20 ± 1.36 vs 1.63 ± 0.89) according to one of the included studies. Meta-regression revealed that the baseline ADR < 25% of the included studies was associated with significant benefit of oral simethicone; the number needed to treat was 15. CONCLUSIONS: The adjunction of oral simethicone significantly improved bowel preparation quality and might benefit adenoma detection in specific settings with low baseline ADR.


Assuntos
Adenoma/diagnóstico , Antiespumantes/administração & dosagem , Catárticos/administração & dosagem , Neoplasias do Colo/diagnóstico , Simeticone/administração & dosagem , Colonoscopia , Bases de Dados Bibliográficas , Humanos , Pólipos Intestinais/diagnóstico , Ensaios Clínicos Controlados Aleatórios como Assunto
10.
World J Gastroenterol ; 24(26): 2893-2901, 2018 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-30018484

RESUMO

AIM: To test the feasibility and performance of a novel upper gastrointestinal (GI) capsule endoscope using a nurse-led protocol. METHODS: We conducted a prospective cohort analysis of patients who declined gastroscopy (oesophagogastroduodenoscopy, OGD) but who consented to upper GI capsule endoscopy. Patients swallowed the upper GI capsule following ingestion of 1 liter of water (containing simethicone). A series of positional changes were used to exploit the effects of water flow and move the upper GI capsule from one gravity-dependent area to another using a nurse-led protocol. Capsule transit time, video reading time, mucosal visualisation, pathology detection and patient tolerance was evaluated. RESULTS: Fifty patients were included in the study. The mean capsule transit times in the oesophagus and stomach were 28 s and 68 min respectively. Visualisation of the following major anatomical landmarks was achieved (graded 1-5: Poor to excellent): Oesophagus, 4.8 (± 0.5); gastro-oesophageal junction (GOJ), 4.8 (± 0.8); cardia, 4.8 (± 0.8); fundus, 3.8 (± 1.2); body, 4.5 (± 1); antrum, 4.5 (± 1); pylorus, 4.7 (± 0.8); duodenal bulb, 4.7 (± 0.7); second part of the duodenum (D2), 4.7 (± 1). The upper GI capsule reached D2 in 64% of patients. The mean video reading time was 48 min with standard playback mode and 20 min using Quickview (P = 0.0001). No pathology was missed using Quickview. Procedural tolerance was excellent. No complications were seen with the upper GI capsule. CONCLUSION: The upper GI capsule achieved excellent views of the upper GI tract. Future studies should compare the diagnostic accuracy between upper GI capsule and OGD.


Assuntos
Endoscopia por Cápsula/métodos , Endoscopia Gastrointestinal/métodos , Padrões de Prática em Enfermagem , Adulto , Idoso , Antiespumantes/administração & dosagem , Endoscopia por Cápsula/efeitos adversos , Endoscopia Gastrointestinal/efeitos adversos , Mucosa Esofágica/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Mucosa Gástrica/diagnóstico por imagem , Trânsito Gastrointestinal , Humanos , Masculino , Pessoa de Meia-Idade , Posicionamento do Paciente , Estudos Prospectivos , Simeticone/administração & dosagem , Gravação em Vídeo
11.
Digestion ; 98(4): 217-221, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30045043

RESUMO

BACKGROUND AND AIMS: Simethicone is a common antifoaming agent that is added to endoscopic rinse solutions, but data regarding its effect on polyp detection rates is lacking. In this study, we report the effect of discontinuation of this practice on polyp detection rates. METHODS: Procedure data of 4,254 consecutive colonoscopies were used. Patients underwent standard bowel preparation with polyethyleneglycol (Glycoprep®). Colonoscopies were performed utilising Olympus EVIS EXERA III, CV-190 equipment, while quality data (withdraw times, polyp detection rates, quality of bowel preparation) was assessed utilising an endoscopy reporting system (Provation®). Following an educational event that highlighted that simethicone may form deposits in the channels of endoscopes, the practice to add simethicone (InfacolR, Nice Pak) to the auxiliary channel water pump was abandoned, but endoscopists were not notified about this change. After 5 days and performing 75 colonoscopies, the change of practice was identified and addition of simethicone recommenced. RESULTS: The discontinuation of simethicone use reduced the polyp detection rate from 55% (95% CI 53-56) to 45% (95% CI 34-56, 1-sided, p = 0.028); the polyp detection rate returned to the pre-intervention levels of 55% (95% CI 52-58) upon resumption of normal practice. CONCLUSION: The addition of simethicone to the auxiliary water pump during colonoscopy results in a 10% increase in polyp detection rates.


Assuntos
Antiespumantes/administração & dosagem , Pólipos do Colo/diagnóstico por imagem , Colonoscopia/métodos , Simeticone/administração & dosagem , Estudos de Coortes , Colonoscópios , Colonoscopia/instrumentação , Combinação de Medicamentos , Humanos , Polietilenoglicóis/administração & dosagem , Cloreto de Potássio/administração & dosagem , Bicarbonato de Sódio/administração & dosagem , Cloreto de Sódio/administração & dosagem , Sulfatos/administração & dosagem
12.
Endoscopy ; 50(4): 423-446, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29539652

RESUMO

SMALL-BOWEL CAPSULE ENDOSCOPY (SBCE): 1: ESGE recommends that prior to SBCE patients ingest a purgative (2 L of polyethylene glycol [PEG]) for better visualization.Strong recommendation, high quality evidence.However, the optimal timing for taking purgatives is yet to be established. 2: ESGE recommends that SBCE should be performed as an outpatient procedure if possible, since completion rates are higher in outpatients than in inpatients.Strong recommendation, moderate quality evidence. 3: ESGE recommends that patients with pacemakers can safely undergo SBCE without special precautions.Strong recommendation, low quality evidence. 4: ESGE suggests that SBCE can also be safely performed in patients with implantable cardioverter defibrillators and left ventricular assist devices.Weak recommendation, low quality evidence. 5: ESGE recommends the acceptance of qualified nurses and trained technicians as prereaders of capsule endoscopy studies as their competency in identifying pathology is similar to that of medically qualified readers. The responsibility of establishing a diagnosis must however remain with the attending physician.Strong recommendation, moderate quality evidence. 6: ESGE recommends observation in cases of asymptomatic capsule retention.Strong recommendation, moderate quality evidence.In cases where capsule retrieval is indicated, ESGE recommends the use of device-assisted enteroscopy as the method of choice.Strong recommendation, moderate quality evidence. DEVICE-ASSISTED ENTEROSCOPY (DAE): 1: ESGE recommends performing diagnostic DAE as a day-case procedure in patients without significant underlying co-morbidities; in patients with co-morbidities and/or those undergoing a therapeutic procedure, an inpatient stay is recommended.Strong recommendation, low quality evidenceThe choice between different settings also depends on sedation protocols.Strong recommendation, low quality evidence. 2: ESGE suggests that conscious sedation, deep sedation, and general anesthesia are all acceptable alternatives: the choice between them should be governed by procedure complexity, clinical factors, and local organizational protocols.Weak recommendation, low quality evidence. 3: ESGE recommends that the findings of previous diagnostic investigations should guide the choice of insertion route.Strong recommendation, moderate quality evidence.If the location of the small-bowel lesion is unknown or uncertain, ESGE recommends that the antegrade route should be generally preferred.Strong recommendation, low quality evidence.In the setting of massive overt bleeding, ESGE recommends an initial antegrade approach.Strong recommendation, low quality evidence. 4: ESGE recommends that, for balloon-assisted enteroscopy (i. e., single-balloon enteroscopy [SBE] and double-balloon enteroscopy [DBE]), small-bowel insertion depth should be estimated by counting net advancement of the enteroscope during the insertion phase, with confirmation of this estimate during withdrawal.Strong recommendation, low quality evidence.ESGE recommends that, for spiral enteroscopy, insertion depth should be estimated during withdrawal.Strong recommendation, moderate quality evidence. Since the calculated insertion depth is only a rough estimate, ESGE recommends placing a tattoo to mark the identified lesion and/or the deepest point of insertion.Strong recommendation, low quality evidence. 5: ESGE recommends that all endoscopic therapeutic procedures can be undertaken at the time of DAE.Strong recommendation, moderate quality evidence.Moreover, when therapeutic interventions are performed, additional specific safety measures are needed to prevent complications.Strong recommendation, high quality evidence.


Assuntos
Catárticos/administração & dosagem , Sedação Consciente , Sedação Profunda , Endoscopia Gastrointestinal/métodos , Endoscopia Gastrointestinal/normas , Enteropatias/diagnóstico por imagem , Anestesia Geral , Antiespumantes/administração & dosagem , Endoscopia por Cápsula/efeitos adversos , Endoscopia por Cápsula/métodos , Endoscopia por Cápsula/normas , Dióxido de Carbono , Enteroscopia de Duplo Balão/efeitos adversos , Enteroscopia de Duplo Balão/métodos , Enteroscopia de Duplo Balão/normas , Ingestão de Líquidos , Ingestão de Alimentos , Endoscopia Gastrointestinal/efeitos adversos , Fluoroscopia , Humanos , Insuflação/métodos , Insuflação/normas , Intestino Delgado/diagnóstico por imagem , Enteroscopia de Balão Único/efeitos adversos , Enteroscopia de Balão Único/métodos , Enteroscopia de Balão Único/normas
13.
Neth J Med ; 76(1): 27-31, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29380729

RESUMO

BACKGROUND: Small bowel capsule endoscopy (SBCE) is an important diagnostic tool for small-bowel diseases but its quality may be hampered by intraluminal gas. This study evaluated the added value of the anti-foaming agent, simethicone, to a bowel preparation with polyethylene glycol (PEG) on the quality of small bowel visualisation and its use in the Netherlands. METHODS: This was a retrospective, single-blind, cohort study. Patients in the PEG group only received PEG prior to SBCE. Patients in the PEG-S group ingested additional simethicone. Two investigators assessed the quality of small-bowel visualisation using a four-point scale for 'intraluminal gas' and 'faecal contamination'. By means of a survey, the use of anti-foaming agents was assessed in a random sample of 16 Dutch hospitals performing SBCE. RESULTS: The quality of small bowel visualisation in the PEG group (n = 33) was significantly more limited by intraluminal gas when compared with the PEG-S group (n = 31): proximal segment 83.3% in PEG group vs. 18.5% in PEG-S group (p < 0.01), distal segment 66.7% vs. 18.5% respectively (p < 0.01). No difference was observed in the amount of faecal contamination (proximal segment 80.0% PEG vs. 59.3% PEG-S, p = 0.2; distal segment 90.0% PEG vs. 85.2% PEG-S, p = 0.7), mean small bowel transit times (4.0 PEG vs. 3.9 hours PEG-S, p = 0.7) and diagnostic yield (43.3% PEG vs. 22.2% PEG-S, p = 0.16). Frequency of anti-foaming agent use in the Netherlands was low (3/16, 18.8%). CONCLUSION: Simethicone is of added value to a PEG bowel preparation in improving the quality of visualisation of the small bowel by reducing intraluminal gas. At present, the use of anti-foaming agents in SBCE preparation is not standard practice in the Netherlands.


Assuntos
Antiespumantes/administração & dosagem , Endoscopia por Cápsula/métodos , Catárticos/administração & dosagem , Intestino Delgado/diagnóstico por imagem , Simeticone/administração & dosagem , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Estudos Prospectivos , Estudos Retrospectivos , Método Simples-Cego
14.
Endoscopy ; 50(2): 128-136, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28985630

RESUMO

BACKGROUND AND STUDY AIMS: Ideal bowel preparation for colonoscopy requires complete removal of fluid and foam from the colon. Polyethylene glycol (PEG) is widely used for bowel preparation, with antifoaming agents such as simethicone commonly used in combination with PEG. Data on the effect of simethicone on the adenoma detection rate (ADR) were limited. This study therefore aimed to investigate whether preprocedure simethicone could increase the ADR. PATIENTS AND METHODS: This was a prospective, multicenter, endoscopist-blinded randomized controlled trial involving consecutive patients who underwent colonoscopy in six centers in China. Patients were randomly assigned to one of two groups: PEG plus simethicone or PEG alone. The primary outcome was ADR; secondary outcomes were quality of bowel preparation, measured by the Boston bowel preparation scale (BBPS) and bubble scores. RESULTS: 583 patients were included. More adenomas were detected in the PEG plus simethicone group than in the PEG alone group (ADR 21.0 % vs. 14.3 %, P = 0.04; advanced ADR 9.0 % vs. 7.0 %, P = 0.38). The mean number of adenomas detected was 2.20 ±â€Š1.36 vs. 1.63 ±â€Š0.89 (P = 0.02). Patients in the PEG plus simethicone group showed better bowel cleansing efficacy: BBPS ≥ 6 in 88.3 % vs. 75.2 % (P < 0.001) and bubble scores of 1.00 ±â€Š1.26 vs. 3.98 ±â€Š2.50 (P < 0.001). Abdominal bloating was reported less frequently in the PEG plus simethicone group (7.8 % vs. 19.7 %, P < 0.001) than in the PEG alone group. CONCLUSION: Combined use of PEG and simethicone is associated with a significantly increased ADR in a Chinese population.


Assuntos
Adenoma/diagnóstico , Colo/diagnóstico por imagem , Neoplasias do Colo/diagnóstico , Colonoscopia/métodos , Simeticone/administração & dosagem , Administração Oral , Adolescente , Adulto , Idoso , Antiespumantes/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
15.
Endoscopy ; 50(4): 412-422, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29132175

RESUMO

BACKGROUND AND STUDY AIMS: For bowel preparation, using a reduced volume of polyethylene glycol (PEG) solution without influencing its effectiveness would be preferable. While simethicone shows great potential as an adjunctive agent, data on its use are limited. We aimed to clarify whether simethicone added to low-volume PEG solution improved bowel cleansing. PATIENTS AND METHODS : Consecutive adult patients registered for colonoscopy were recruited from seven medical centers in South China between 15 April and 15 July 2015 and prospectively randomized into two groups: 2 L PEG (conventional group) and 2 L PEG plus simethicone (simethicone group). The primary endpoint was the effectiveness of bowel cleansing according to the Boston Bowel Preparation Scale (BBPS). Secondary endpoints included cecal intubation time, adenoma detection rate (ADR), patient safety and compliance, and adverse events. RESULTS : We included 290 and 289 patients in the conventional and simethicone groups, respectively, for analysis. The proportion with acceptable bowel cleansing (BBPS ≥ 6) was significantly higher in the simethicone group than in the conventional group (88.2 % vs. 76.6 %; P < 0.001). The mean (SD) BBPS score was significantly lower in the conventional group (6.5 [1.8] vs. 7.3 [1.7]; P < 0.001), as was the bubble score (2.5 [0.7] vs. 2.8 [0.5]; P < 0.001). The average cecal intubation time was significantly shorter in the simethicone group (6.3 [3.1] vs. 7.5 [5.1] minutes; P < 0.001). The ADR in the right colon was higher in the simethicone group than in the conventional group (16.6 % vs. 10.3 %; P = 0.03). Safety and compliance, including the taste, smell, and dosage of PEG, were similar for both groups. CONCLUSIONS: Simethicone added to low-volume PEG solution improves bowel-cleansing efficacy, with similar safety and compliance, shorter cecal intubation time, and higher ADR.


Assuntos
Adenoma/diagnóstico por imagem , Antiespumantes/administração & dosagem , Catárticos/administração & dosagem , Neoplasias do Colo/diagnóstico por imagem , Colonoscopia , Polietilenoglicóis/administração & dosagem , Simeticone/administração & dosagem , Adulto , Antiespumantes/efeitos adversos , Catárticos/efeitos adversos , Ceco , Feminino , Humanos , Intubação Gastrointestinal , Masculino , Adesão à Medicação , Pessoa de Meia-Idade , Segurança do Paciente , Polietilenoglicóis/efeitos adversos , Estudos Prospectivos , Simeticone/efeitos adversos , Método Simples-Cego , Fatores de Tempo
16.
Gastrointest Endosc ; 87(4): 986-993, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29037773

RESUMO

BACKGROUND AND AIM: Upper GI endoscopy (UGE) is essential for the diagnosis of gastrointestinal diseases. Mucus and bubbles may decrease mucosal visibility. The use of mucolytics could improve visualization. Our aim was to determine whether premedication with simethicone or simethicone plus N-acetylcysteine is effective in improving visibility during UGE. METHODS: This was a randomized, double-blinded, placebo-controlled trial with 2 control groups: no intervention and water 100 mL (W); and 3 intervention groups: simethicone 200 mg (S); S + N-acetylcysteine (NAC) 500 mg (S+NAC500); and S + NAC 1000 mg (S+NAC1000). The solution was ingested 20 minutes before UGE. Gastric visibility was evaluated in 4 segments with a previously described scale. A score of less than 7 points was defined as adequate visibility (AV). Water volume was used to improve visibility, and adverse reactions were evaluated as a secondary outcome. Multiple group comparison was performed using non-parametric one-way analysis of variance (ANOVA). RESULTS: Two hundred thirty patients were included in the study, 68% female, mean age 49 years. The most common indication for UGE was epigastric pain/dyspepsia (33%). AV was more frequent in the S+NAC500 and S+NAC1000 groups (65% and 67%) compared with no intervention (44%, P = .044) and water (41%, P = .022). The gastric total visibility scale (TVS) was significantly better in the S+NAC500 and S+NAC1000 groups compared with water (P = .03 and P = .008). Simethicone was not different from no intervention and water. S+NAC1000 required less water volume to improve visibility. No adverse reactions from the study drugs were observed. CONCLUSIONS: Premedication with S+NAC500 and S+NAC1000 improves visibility during UGE. The use of simethicone did not show improvements in gastric visibility. TVS was worse in patients using water alone. (Clinical trial registration number: NCT 01653171.).


Assuntos
Acetilcisteína/administração & dosagem , Antiespumantes/administração & dosagem , Endoscopia Gastrointestinal/métodos , Expectorantes/administração & dosagem , Mucosa Gástrica/diagnóstico por imagem , Simeticone/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Gastropatias/diagnóstico por imagem , Água/administração & dosagem
17.
Dig Liver Dis ; 50(1): 42-47, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29110963

RESUMO

BACKGROUND AND AIMS: Magnetically controlled capsule endoscopy (MCE) is a novel technique for which there is no agreed gastric preparation. We aimed to determine an optimal standardized gastric preparation regimen. METHODS: 120 patients referred for MCE were randomly assigned to gastric preparation with either water alone (A), water with simethicone (B) or water, simethicone and pronase (C). Image quality was assessed using cleanliness and visualization scores, higher scores equating to better image quality. RESULTS: The total cleanliness scores were (mean±SD) 15.83±2.41 (A), 21.35±1.23 (B), and 20.82±1.90 (C). The total visualization scores (mean±SD) were 10.75±2.02 (A), 15.20±1.32 (B), and 15.08±1.86 (C). While the image quality of the whole stomach in groups B and C were significantly better than group A (P<0.0001), there was no statistical difference between group B and C (P>0.05). MCE detected positive findings in 21 (52.5%), 27 (67.5%) and 21 (53.8%) patients in group A, B and C respectively, with no significant difference between groups (P>0.5). CONCLUSIONS: Simethicone swallowed with water prior to MCE produced the optimal gastric mucosal image quality. The addition of pronase had no demonstrable additional benefit.


Assuntos
Antiespumantes/administração & dosagem , Pronase/administração & dosagem , Simeticone/administração & dosagem , Adulto , Idoso , Endoscopia por Cápsula/instrumentação , China , Feminino , Humanos , Aumento da Imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Método Simples-Cego , Estômago/fisiologia , Gastropatias/diagnóstico , Adulto Jovem
18.
Acta Vet Scand ; 59(1): 48, 2017 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-28716083

RESUMO

Presence of significant quantities of gas in the intestines may hinder a proper conduction of abdominal ultrasonography. In humans, preparatory techniques are used to solve this, but measures to avoid ultrasonographic complications due to intestinal gas in rabbits have not been reported. The objective of this study was to evaluate the influence of fasting and simethicone administered orally on the quality of ultrasonographic images of the gallbladder, kidneys, and jejunum in adult New Zealand White (NZW) rabbits. A total of 28 adult NZW rabbits were included in a crossover design study, involving four groups: F: fasting for 4-6 h before the examination; FS: fasting and application of simethicone (20 mg/kg, orally) 20 to 30 min before the examination; S: application of simethicone 20-30 min before the examination without fasting; and C: controls without fasting and no application of simethicone. Evaluation of the ultrasonographic images was done in terms of percentage of visualization of each organ and image quality using a 3-point scoring system (unacceptable, acceptable, or excellent). The kidneys and the gallbladder were visualized at an equal frequency in all groups, while the jejunum was visualized more frequently in the FS group. The image quality scores for gallbladder, right kidney, and left kidney was similar for all groups, but for the jejunum, a higher number of images with acceptable scores was found within the FS group.


Assuntos
Antiespumantes/administração & dosagem , Jejum , Enteropatias/veterinária , Simeticone/administração & dosagem , Administração Oral , Animais , Estudos Cross-Over , Vesícula Biliar/diagnóstico por imagem , Enteropatias/diagnóstico por imagem , Jejuno/diagnóstico por imagem , Rim/diagnóstico por imagem , Coelhos , Ultrassonografia
19.
Medicine (Baltimore) ; 95(28): e4163, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27428209

RESUMO

BACKGROUND AND AIM: Low-volume polyethylene glycol with ascorbic acid (PEG-Asc) use is reported to be as safe and effective as traditional 4-L polyethylene glycol use. However, PEG-Asc produces bubbles, which cause problems during colonoscopy. Data on the effects of using antifoaming agents such as simethicone with PEG-Asc are lacking. The aim of this CONSORT-prospective, randomized, observer-blinded, controlled trial is to compare the quality of bowel preparation and compliance between PEG-Asc users and PEG-Asc plus simethicone users. METHODS: Adult outpatients aged 18 to 80 years undergoing colonoscopy were recruited to the study. Two hundred sixty patients were randomly assigned to 1 of 2 treatment arms, PEG-Asc or PEG-Asc plus simethicone. The primary outcome measure was the bowel cleansing quality using Boston bowel preparation scale and bubble scores. The secondary outcome measures were patient tolerability and doctor tolerability. RESULTS: The simethicone group showed superior cleansing results (6-9 Boston scale scores: 99% vs. 84%, <5% bubble scores: 96% vs. 49%, P < 0.001) and fewer gastrointestinal symptoms (abdominal fullness: 24% vs. 55%, colicky pain: 5% vs. 24%, P < 0.001) than the non-simethicone group. Moreover, endoscopist fatigue during colonoscopy was lower in the simethicone group than in the non-simethicone group (1.31 ±â€Š0.75 vs. 2.97 ±â€Š2.14, P < 0.001). CONCLUSION: PEG-Asc plus simethicone use was more effective and associated with better patient and endoscopist tolerance than PEG-Asc use. Therefore, this combination is recommended as one of the promising methods for bowel preparation before colonoscopy.


Assuntos
Antiespumantes/administração & dosagem , Ácido Ascórbico/administração & dosagem , Catárticos/administração & dosagem , Polietilenoglicóis/administração & dosagem , Simeticone/administração & dosagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Colonoscopia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
20.
Saudi J Gastroenterol ; 22(2): 122-6, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26997218

RESUMO

BACKGROUND/AIMS: Bile is the main cause of poor bowel preparation for capsule endoscopy (CE). We aimed to determine whether cholestyramine and hydrotalcite can eliminate bile in the bowel. PATIENTS AND METHODS: Patients undergoing CE were randomized into two groups. Group A patients (n = 75) received 250 mL 20% mannitol and 1 L 0.9% saline orally at 20:00 hours on the day before and at 05:00 hours on the day of CE and 20 mL simethicone 30 min before CE. Group B patients (n = 73) were treated identically, except for taking oral cholestyramine and hydrotalcite, starting 3 days before CE. Greenish luminal contents were assessed by four tissue color bar segments using Color Area Statistics software. Bowel cleanliness was evaluated by visualized area percentage assessment of cleansing (AAC) score. RESULT: Bowel cleanliness (82.7% [62/75] vs 46.6% [34/73]; χ2 = 14.596, P = 0.000). and detected greenish luminal contents (20.0% [15/75] vs 8.2% [6/73]; χ2 = 4.217, P = 0.040) were significantly greater in Group A than in Group B. Greenish luminal contents in the two groups differed significantly in the captured small-bowel (t = -13.74, P = 0.000) segments and proximal small-bowel (t = -0.7365, P = 0.000) segments, but not for the distal small-bowel (t = -0.552, P = 0.581) segments. CONCLUSIONS: Cholestyramine and hydrotalcite were ineffective in eliminating bile and improving small-bowel preparation.


Assuntos
Hidróxido de Alumínio/administração & dosagem , Bile/efeitos dos fármacos , Endoscopia por Cápsula/métodos , Resina de Colestiramina/administração & dosagem , Hidróxido de Magnésio/administração & dosagem , Administração Oral , Adulto , Antiespumantes/administração & dosagem , Feminino , Humanos , Intestino Delgado/diagnóstico por imagem , Intestino Delgado/efeitos dos fármacos , Intestino Delgado/metabolismo , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...