Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 10.404
Filtrar
1.
Sci Rep ; 14(1): 10428, 2024 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-38714762

RESUMO

Muscle strength assessments are vital in rehabilitation, orthopedics, and sports medicine. However, current methods used in clinical settings, such as manual muscle testing and hand-held dynamometers, often lack reliability, and isokinetic dynamometers (IKD), while reliable, are not easily portable. The aim of this study was to design and validate a wearable dynamometry system with high accessibility, accuracy, and reliability, and to validate the device. Therefore, we designed a wearable dynamometry system (WDS) equipped with knee joint torque sensors. To validate this WDS, we measured knee extension and flexion strength in 39 healthy adults using both the IKD and WDS. Comparing maximal isometric torque measurements, WDS and IKD showed strong correlation and good reliability for extension (Pearson's r: 0.900; intraclass correlation coefficient [ICC]: 0.893; standard error of measurement [SEM]: 9.85%; minimal detectable change [MDC]: 27.31%) and flexion (Pearson's r: 0.870; ICC: 0.857; SEM: 11.93%; MDC: 33.07%). WDS demonstrated excellent inter-rater (Pearson's r: 0.990; ICC: 0.993; SEM: 4.05%) and test-retest (Pearson's r: 0.970; ICC: 0.984; SEM: 6.15%) reliability during extension/flexion. User feedback from 35 participants, including healthcare professionals, underscores WDS's positive user experience and clinical potential. The proposed WDS is a suitable alternative to IKD, providing high accuracy, reliability, and potentially greater accessibility.


Assuntos
Articulação do Joelho , Dinamômetro de Força Muscular , Força Muscular , Torque , Dispositivos Eletrônicos Vestíveis , Humanos , Masculino , Adulto , Feminino , Articulação do Joelho/fisiologia , Força Muscular/fisiologia , Reprodutibilidade dos Testes , Amplitude de Movimento Articular/fisiologia , Adulto Jovem , Desenho de Equipamento
2.
PLoS One ; 19(5): e0302867, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38743754

RESUMO

Despite evidence on trunk flexion's impact on locomotion mechanics, its role in modulating lower-limb energetics during perturbed running remains underexplored. Therefore, we investigated posture-induced power redistribution in the lower-limb joints (hip, knee, and ankle), along with the relative contribution from each joint to total lower-limb average positive and negative mechanical powers (i.e., over time) during perturbed running. Twelve runners (50% female) ran at self-selected (~15°) and three more sagittal trunk inclinations (backward, ~0°; low forward, ~20°; high forward, ~25°) on a custom-built runway, incorporating both a level surface and a 10 cm visible drop-step positioned midway, while simultaneously recording three-dimensional kinematics and kinetics. We used inverse dynamics analysis to determine moments and powers in lower-limb joints. Increasing the trunk forward inclination yielded the following changes in lower-limb mechanics: a) an elevation in total positive power with a distoproximal shift and a reduction in total negative power; b) systematic increases in hip positive power, coupled with decreased and increased contribution to total negative (during level-step) and positive (during drop-step) powers, respectively; c) reductions in both negative and positive knee powers, along with a decrease in its contribution to total positive power. Regardless of the trunk posture, accommodating drop-steps while running demands elevated total limb negative and positive powers with the ankle as a primary source of energy absorption and generation. Leaning the trunk more forward induces a distoproximal shift in positive power, whereas leaning backward exerts an opposing influence on negative power within the lower-limb joints.


Assuntos
Articulação do Tornozelo , Articulação do Joelho , Extremidade Inferior , Postura , Corrida , Humanos , Corrida/fisiologia , Feminino , Masculino , Postura/fisiologia , Fenômenos Biomecânicos , Adulto , Articulação do Tornozelo/fisiologia , Articulação do Joelho/fisiologia , Extremidade Inferior/fisiologia , Articulação do Quadril/fisiologia , Adulto Jovem
3.
Ann Biomed Eng ; 52(6): 1591-1603, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38558356

RESUMO

Kinematic tracking of native anatomy from stereo-radiography provides a quantitative basis for evaluating human movement. Conventional tracking procedures require significant manual effort and call for acquisition and annotation of subject-specific volumetric medical images. The current work introduces a framework for fully automatic tracking of native knee anatomy from dynamic stereo-radiography which forgoes reliance on volumetric scans. The method consists of three computational steps. First, captured radiographs are annotated with segmentation maps and anatomic landmarks using a convolutional neural network. Next, a non-convex polynomial optimization problem formulated from annotated landmarks is solved to acquire preliminary anatomy and pose estimates. Finally, a global optimization routine is performed for concurrent refinement of anatomy and pose. An objective function is maximized which quantifies similarities between masked radiographs and digitally reconstructed radiographs produced from statistical shape and intensity models. The proposed framework was evaluated against manually tracked trials comprising dynamic activities, and additional frames capturing a static knee phantom. Experiments revealed anatomic surface errors routinely below 1.0 mm in both evaluation cohorts. Median absolute errors of individual bone pose estimates were below 1.0 ∘ or mm for 15 out of 18 degrees of freedom in both evaluation cohorts. Results indicate that accurate pose estimation of native anatomy from stereo-radiography may be performed with significantly reduced manual effort, and without reliance on volumetric scans.


Assuntos
Joelho , Humanos , Joelho/diagnóstico por imagem , Joelho/anatomia & histologia , Joelho/fisiologia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/anatomia & histologia , Articulação do Joelho/fisiologia , Imagens de Fantasmas , Radiografia , Modelos Estatísticos
4.
Sensors (Basel) ; 24(8)2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38676022

RESUMO

Exoskeletons designed to assist patients with activities of daily living are becoming increasingly popular, but still are subject to research. In order to gather requirements for the design of such systems, long-term gait observation of the patients over the course of multiple days in an environment of daily living are required. In this paper a wearable all-in-one data acquisition system for collecting and storing biomechanical data in everyday life is proposed. The system is designed to be cost efficient and easy to use, using off-the-shelf components and a cloud server system for centralized data storage. The measurement accuracy of the system was verified, by measuring the angle of the human knee joint at walking speeds between 3 and 12 km/h in reference to an optical motion analysis system. The acquired data were uploaded to a cloud database via a smartphone application. Verification results showed that the proposed toolchain works as desired. The system reached an RMSE from 2.9° to 8°, which is below that of most comparable systems. The system provides a powerful, scalable platform for collecting and processing biomechanical data, which can help to automize the generation of an extensive database for human kinematics.


Assuntos
Computação em Nuvem , Dispositivos Eletrônicos Vestíveis , Humanos , Fenômenos Biomecânicos/fisiologia , Articulação do Joelho/fisiologia , Marcha/fisiologia , Smartphone , Caminhada/fisiologia , Atividades Cotidianas
5.
Sensors (Basel) ; 24(8)2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38676056

RESUMO

This paper introduces a method for measuring 3D tibiofemoral kinematics using a multi-channel A-mode ultrasound system under dynamic conditions. The proposed system consists of a multi-channel A-mode ultrasound system integrated with a conventional motion capture system (i.e., optical tracking system). This approach allows for the non-invasive and non-radiative quantification of the tibiofemoral joint's six degrees of freedom (DOF). We demonstrated the feasibility and accuracy of this method in the cadaveric experiment. The knee joint's motions were mimicked by manually manipulating the leg through multiple motion cycles from flexion to extension. To measure it, six custom ultrasound holders, equipped with a total of 30 A-mode ultrasound transducers and 18 optical markers, were mounted on various anatomical regions of the lower extremity of the specimen. During experiments, 3D-tracked intra-cortical bone pins were inserted into the femur and tibia to measure the ground truth of tibiofemoral kinematics. The results were compared with the tibiofemoral kinematics derived from the proposed ultrasound system. The results showed an average rotational error of 1.51 ± 1.13° and a translational error of 3.14 ± 1.72 mm for the ultrasound-derived kinematics, compared to the ground truth. In conclusion, this multi-channel A-mode ultrasound system demonstrated a great potential of effectively measuring tibiofemoral kinematics during dynamic motions. Its improved accuracy, nature of non-invasiveness, and lack of radiation exposure make this method a promising alternative to incorporate into gait analysis and prosthetic kinematic measurements later.


Assuntos
Imageamento Tridimensional , Articulação do Joelho , Ultrassonografia , Humanos , Fenômenos Biomecânicos , Articulação do Joelho/fisiologia , Articulação do Joelho/diagnóstico por imagem , Ultrassonografia/métodos , Imageamento Tridimensional/métodos , Tíbia/diagnóstico por imagem , Tíbia/fisiologia , Amplitude de Movimento Articular/fisiologia , Fêmur/fisiologia , Fêmur/diagnóstico por imagem , Joelho/fisiologia , Joelho/diagnóstico por imagem
6.
Sensors (Basel) ; 24(8)2024 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-38676133

RESUMO

Two-dimensional (2D) clinical gait analysis systems are more affordable and portable than contemporary three-dimensional (3D) clinical models. Using the Vicon 3D motion capture system as the standard, we evaluated the internal statistics of the Imasen and open-source OpenPose gait measurement systems, both designed for 2D input, to validate their output based on the similarity of results and the legitimacy of their inner statistical processes. We measured time factors, distance factors, and joint angles of the hip and knee joints in the sagittal plane while varying speeds and gaits during level walking in three in-person walking experiments under normal, maximum-speed, and tandem scenarios. The intraclass correlation coefficients of the 2D models were greater than 0.769 for all gait parameters compared with those of Vicon, except for some knee joint angles. The relative agreement was excellent for the time-distance gait parameter and moderate-to-excellent for each gait motion contraction range, except for hip joint angles. The time-distance gait parameter was high for Cronbach's alpha coefficients of 0.899-0.993 but low for 0.298-0.971. Correlation coefficients were greater than 0.571 for time-distance gait parameters but lower for joint angle parameters, particularly hip joint angles. Our study elucidates areas in which to improve 2D models for their widespread clinical application.


Assuntos
Algoritmos , Análise da Marcha , Marcha , Articulação do Quadril , Articulação do Joelho , Caminhada , Humanos , Análise da Marcha/métodos , Marcha/fisiologia , Articulação do Quadril/fisiologia , Articulação do Joelho/fisiologia , Caminhada/fisiologia , Masculino , Fenômenos Biomecânicos/fisiologia , Adulto , Amplitude de Movimento Articular/fisiologia , Postura/fisiologia , Feminino
7.
Sensors (Basel) ; 24(8)2024 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-38676262

RESUMO

Knee rehabilitation therapy after trauma or neuromotor diseases is fundamental to restore the joint functions as best as possible, exoskeleton robots being an important resource in this context, since they optimize therapy by applying tailored forces to assist or resist movements, contributing to improved patient outcomes and treatment efficiency. One of the points that must be taken into account when using robots in rehabilitation is their interaction with the patient, which must be safe for both and guarantee the effectiveness of the treatment. Therefore, the objective of this study was to assess the interaction between humans and an exoskeleton during the execution of knee flexion-extension movements under various configurations of robot assistance and resistance. The evaluation encompassed considerations of myoelectric activity, muscle recruitment, robot torque, and performed movement. To achieve this, an experimental protocol was implemented, involving an individual wearing the exoskeleton and executing knee flexion-extension motions while seated, with the robot configured in five distinct modes: passive (P), assistance on flexion (FA), assistance on extension (EA), assistance on flexion and extension (CA), and resistance on flexion and extension (CR). Results revealed distinctive patterns of movement and muscle recruitment for each mode, highlighting the complex interplay between human and robot; for example, the largest RMS tracking errors were for the EA mode (13.72 degrees) while the smallest for the CR mode (4.47 degrees), a non-obvious result; in addition, myoelectric activity was demonstrated to be greater for the completely assisted mode than without the robot (the maximum activation levels for the vastus medialis and vastus lateralis muscles were more than double those when the user had assistance from the robot). Tracking errors, muscle activations, and torque values varied across modes, emphasizing the need for careful consideration in configuring exoskeleton assistance and resistance to ensure effective and safe rehabilitation. Understanding these human-robot interactions is essential for developing precise rehabilitation programs, optimizing treatment effectiveness, and enhancing patient safety.


Assuntos
Exoesqueleto Energizado , Articulação do Joelho , Robótica , Humanos , Robótica/métodos , Articulação do Joelho/fisiologia , Masculino , Amplitude de Movimento Articular/fisiologia , Fenômenos Biomecânicos , Eletromiografia/métodos , Adulto , Torque , Músculo Esquelético/fisiologia , Joelho/fisiologia , Movimento/fisiologia
8.
Scand J Med Sci Sports ; 34(5): e14639, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38686976

RESUMO

BACKGROUND: Associations between muscle architecture and rate of force development (RFD) have been largely studied during fixed-end (isometric) contractions. Fixed-end contractions may, however, limit muscle shape changes and thus alter the relationship between muscle architecture an RFD. AIM: We compared the correlation between muscle architecture and architectural gearing and knee extensor RFD when assessed during dynamic versus fixed-end contractions. METHODS: Twenty-two recreationally active male runners performed dynamic knee extensions at constant acceleration (2000°s-2) and isometric contractions at a fixed knee joint angle (fixed-end contractions). Torque, RFD, vastus lateralis muscle thickness, and fascicle dynamics were compared during 0-75 and 75-150 ms after contraction onset. RESULTS: Resting fascicle angle was moderately and positively correlated with RFD during fixed-end contractions (r = 0.42 and 0.46 from 0-75 and 75-150 ms, respectively; p < 0.05), while more strongly (p < 0.05) correlated with RFD during dynamic contractions (r = 0.69 and 0.73 at 0-75 and 75-150 ms, respectively; p < 0.05). Resting fascicle angle was (very) strongly correlated with architectural gearing (r = 0.51 and 0.73 at 0-75 ms and 0.50 and 0.70 at 75-150 ms; p < 0.05), with gearing in turn also being moderately to strongly correlated with RFD in both contraction conditions (r = 0.38-0.68). CONCLUSION: Resting fascicle angle was positively correlated with RFD, with a stronger relationship observed in dynamic than isometric contraction conditions. The stronger relationships observed during dynamic muscle actions likely result from different restrictions on the acute changes in muscle shape and architectural gearing imposed by isometric versus dynamic muscle contractions.


Assuntos
Contração Isométrica , Torque , Humanos , Masculino , Contração Isométrica/fisiologia , Adulto Jovem , Adulto , Músculo Quadríceps/fisiologia , Músculo Quadríceps/anatomia & histologia , Músculo Quadríceps/diagnóstico por imagem , Corrida/fisiologia , Articulação do Joelho/fisiologia , Força Muscular/fisiologia , Fenômenos Biomecânicos
9.
Comput Biol Med ; 175: 108492, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38678940

RESUMO

Exploring the torque modulation mechanisms of human joints is critical for analyzing the human balance control system and developing natural human-machine interactions for balance support. However, the knee joint is often overlooked in biomechanical models because of its limited range of motion during balance recovery. This poses a challenge in establishing mathematical models for the knee joint's torque modulation mechanisms using computer simulations based on the inverted pendulum model. This study aims to provide a simplified linear feedback model inspired by sensorimotor transformation theory to reveal the torque modulation mechanism of the knee joint. The model was validated using data from experiments involving support-surface translation perturbations. The goodness-of-fit metrics of the model, including R2 values and root mean square errors (RMSE), demonstrated strong explanatory power (R2 ranged from 0.77 to 0.90) and low error (RMSE ranging from 0.035 to 0.072) across different perturbation magnitudes and directions. Through pooling samples across various perturbation conditions and conducting multiple fits, this model revealed that knee torque is modulated using a direction-specific strategy with adaptable feedback gains. These results suggest that the proposed simplified linear model can be used to develop assistive systems and retrieve insights on balance recovery mechanisms.


Assuntos
Articulação do Joelho , Modelos Biológicos , Equilíbrio Postural , Torque , Humanos , Articulação do Joelho/fisiologia , Equilíbrio Postural/fisiologia , Masculino , Adulto , Fenômenos Biomecânicos/fisiologia , Simulação por Computador , Feminino , Adulto Jovem
10.
J Biomech Eng ; 146(10)2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-38683101

RESUMO

Understanding the biomechanical impact of injuries and reconstruction of the anterior cruciate ligament (ACL) is vital for improving surgical treatments that restore normal knee function. The purpose of this study was to develop a technique that enables parametric analysis of the effect of the ACL reconstruction (ACLR) in cadaver knees, by replacing its contributions with that of a specimen-specific virtual ACLR that can be enabled, disabled, or modified. Twelve ACLR reconstructed knees were mounted onto a motion simulator. In situ ACLR graft forces were measured using superposition, and these data were used to design specimen-specific virtual ACLRs that would yield the same ligament force-elongation behaviors. Tests were then repeated using the virtual ACLR in place of the real ACLR and following that in ACL deficient knee by disabling the virtual ACLR. In comparison to the ACL deficient state, the virtual ACLRs were able to restore knee stability to the same extent as real ACLRs. The average differences between the anterior tibial translation (ATT) of the virtual ACLR versus the real ACLR were +1.6 ± 0.9 mm (p = 0.4), +2.1 ± 0.4 mm (p = 0.4), and +1.0 ± 0.9 mm (p = 0.4) during Anterior drawer, Lachman and Pivot-shift tests, respectively, which is small in comparison to the full ATT range of motion (ROM) of these knees. Therefore, we conclude that a virtual ACLR can be used in place of real ACLR during biomechanical testing of cadaveric knees. This capability opens the door for future studies that can leverage parameterization of the ACLR for surgical design optimization.


Assuntos
Reconstrução do Ligamento Cruzado Anterior , Articulação do Joelho , Fenômenos Mecânicos , Humanos , Fenômenos Biomecânicos , Articulação do Joelho/cirurgia , Articulação do Joelho/fisiologia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Amplitude de Movimento Articular
11.
Arch Orthop Trauma Surg ; 144(5): 2267-2271, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38587669

RESUMO

The symmetry of the flexion and extension gap influences the functional and long-term outcome after total knee arthroplasty (TKA). Most surgeons check it by applying varus and valgus stress using spacers. This technique has limited accuracy and could be easily extended by rotational movement of the spacer. The objective was to determine the detection threshold and interobserver reliability of this technique. In an in vitro setting with a human cadaveric knee, gap asymmetries were simulated by different medially and laterally applied forces. Using an optical measurement system, the pivot point of the spacer was calculated as a function of the gap symmetry in the first part of the experiment. In the second part, the detection threshold and interobserver reliability of 4 surgeons were determined. For this purpose, gap asymmetries were adjusted to between 0 and 120N in a blinded trial. With a symmetrical gap, the centre of rotation of the spacer was located in the centre of the tibia. With increasing gap asymmetry, the centre of rotation of the spacer shifted to the tight side. This shift was approximately linearly dependent on the force difference. A perfectly balanced gap was detected by the examiners in 50% of the cases. From a force difference of 40N, all examiners identified the gap asymmetry in all cases (ICC = 1.0). The method of spacer rotation described is suitable for reliably detecting gap differences at ≥ 40N, independently of the examiner.


Assuntos
Artroplastia do Joelho , Cadáver , Humanos , Artroplastia do Joelho/métodos , Rotação , Prótese do Joelho , Amplitude de Movimento Articular , Articulação do Joelho/cirurgia , Articulação do Joelho/fisiologia , Articulação do Joelho/fisiopatologia , Fenômenos Biomecânicos , Variações Dependentes do Observador
12.
Scand J Med Sci Sports ; 34(5): e14635, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38671558

RESUMO

The aim was to determine how jump load affects knee complaints in elite men's volleyball. We collected data from four men's premier league volleyball teams through three seasons in a prospective cohort study (65 players, 102 player-seasons). Vert inertial measurement devices captured the jump load (jump frequency and jump height) from 21 088 daily player sessions, and knee complaints were reported in 3568 weekly OSTRC-O questionnaires. Mixed complementary log-log regression models described the probability of (i) experiencing symptoms if players were currently asymptomatic, (ii) worsening symptoms if players had symptoms, and (iii) recovery from knee complaints. Based on our causal assumptions, weekly jump load was modeled as the independent variable, adjusted for age (years), weight (kg), position on volleyball team, and past jump load. No certain evidence of an association was found between weekly jump load and probability of (i) knee complaints (p from 0.10 to 0.32 for three restricted cubic splines of load), (ii) worsening symptoms if the player already had symptoms (p from 0.11 to 0.97), (iii) recovery (p from 0.36 to 0.63). The probability of knee complaints was highest for above-average weekly jump load (~1.2% for an outside hitter with mean age and height) compared with low loads (~1%) and very high loads (→ ~ 0%). The association between jump load and knee complaints risk remains unclear. Small differences in risk across observed jump load levels were observed. It would likely require substantially increased sample sizes to detect this association with certainty.


Assuntos
Voleibol , Humanos , Masculino , Voleibol/lesões , Estudos Prospectivos , Adulto Jovem , Adulto , Articulação do Joelho/fisiologia , Inquéritos e Questionários
13.
Sci Rep ; 14(1): 9542, 2024 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-38664550

RESUMO

The introduction of women into U.S. military ground close combat roles requires research into sex-specific effects of military training and operational activities. Knee osteoarthritis is prevalent among military service members; its progression has been linked to occupational tasks such as load carriage. Analyzing tibiofemoral arthrokinematics during load carriage is important to understand potentially injurious motion and osteoarthritis progression. The study purpose was to identify effects of load carriage on knee arthrokinematics during walking and running in recruit-aged women. Twelve healthy recruit-aged women walked and ran while unloaded (bodyweight [BW]) and carrying additional + 25%BW and + 45%BW. Using dynamic biplane radiography and subject-specific bone models, tibiofemoral arthrokinematics, subchondral joint space and center of closest contact location between subchondral bone surfaces were analyzed over 0-30% stance (separate one-way repeated measures analysis of variance, load by locomotion). While walking, medial compartment contact location was 5% (~ 1.6 mm) more medial for BW than + 45%BW at foot strike (p = 0.03). While running, medial compartment contact location was 4% (~ 1.3 mm) more lateral during BW than + 25%BW at 30% stance (p = 0.04). Internal rotation was greater at + 45%BW compared to + 25%BW (p < 0.01) at 30% stance. Carried load affects tibiofemoral arthrokinematics in recruit-aged women. Prolonged load carriage could increase the risk of degenerative joint injury in physically active women.


Assuntos
Articulação do Joelho , Caminhada , Suporte de Carga , Humanos , Feminino , Suporte de Carga/fisiologia , Caminhada/fisiologia , Articulação do Joelho/fisiologia , Adulto , Corrida/fisiologia , Militares , Fenômenos Biomecânicos , Fêmur/fisiologia , Fêmur/diagnóstico por imagem , Osteoartrite do Joelho/fisiopatologia , Osteoartrite do Joelho/etiologia , Tíbia/fisiologia , Tíbia/diagnóstico por imagem , Adulto Jovem
14.
Med Eng Phys ; 126: 104130, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38621832

RESUMO

Biphasic models have been widely used to simulate the time-dependent biomechanical response of soft tissues. Modelling techniques of joints with biphasic weight-bearing soft tissues have been markedly improved over the last decade, enhancing our understanding of the function, degenerative mechanism and outcomes of interventions of joints. This paper reviews the recent advances, challenges and opportunities in computational models of joints with biphasic weight-bearing soft tissues. The review begins with an introduction of the function and degeneration of joints from a biomechanical aspect. Different constitutive models of articular cartilage, in particular biphasic materials, are illustrated in the context of the study of contact mechanics in joints. Approaches, advances and major findings of biphasic models of the hip and knee are presented, followed by a discussion of the challenges awaiting to be addressed, including the convergence issue, high computational cost and inadequate validation. Finally, opportunities and clinical insights in the areas of subject-specific modeling and tissue engineering are provided and discussed.


Assuntos
Cartilagem Articular , Modelos Biológicos , Humanos , Fenômenos Biomecânicos , Articulações/fisiologia , Cartilagem Articular/fisiologia , Simulação por Computador , Articulação do Joelho/fisiologia , Análise de Elementos Finitos
15.
J Biomech ; 167: 112030, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38583375

RESUMO

Young female athletes participating in sports requiring rapid changes of direction are at heightened risk of suffering traumatic knee injury, especially noncontact rupture of the anterior cruciate ligament (ACL). Clinical studies have revealed that geometric features of the tibiofemoral joint are associated with increased risk of suffering noncontact ACL injury. However, the relationship between three-dimensional (3D) tibiofemoral geometry and knee mechanics in young female athletes is not well understood. We developed a statistically augmented computational modeling workflow to determine relationships between 3D geometry of the knee and tibiofemoral kinematics and ACL force in response to an applied loading sequence of compression, valgus, and anterior force, which is known to load the ACL. This workflow included 3D characterization of tibiofemoral bony geometry via principal component analysis and multibody dynamics models incorporating subject-specific knee geometries. A combination of geometric features of both the tibia and the femur that spanned all three anatomical planes was related to increased ACL force and to increased kinematic coupling (i.e., anterior, medial, and distal tibial translations and internal tibial rotation) in response to the applied loads. In contrast, a uniplanar measure of tibiofemoral geometry that is associated with ACL injury risk, sagittal plane slope of the lateral tibial plateau subchondral bone, was not related to ACL force. Thus, our workflow may aid in developing mechanics-based ACL injury screening tools for young, active females based on a unique combination of bony geometric features that are related to increased ACL loading.


Assuntos
Lesões do Ligamento Cruzado Anterior , Humanos , Feminino , Lesões do Ligamento Cruzado Anterior/complicações , Articulação do Joelho/fisiologia , Ligamento Cruzado Anterior/fisiologia , Tíbia/fisiologia , Atletas , Simulação por Computador , Fenômenos Biomecânicos
16.
PLoS One ; 19(4): e0297910, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38603690

RESUMO

Dynamic knee valgus (DKV) occurs during landing after a fatigue task involving the lower extremity. However, the manner in which different peripheral fatigue tasks affect DKV remains unknown. In this study, we investigated the DKV via electromyography during single-leg landing considering the hip-joint fatigue task (HFT) and knee-joint fatigue task (KFT) performed by healthy men. We recruited 16 healthy male participants who performed a single-leg jump-landing motion from a height of 20 cm before and after an isokinetic hip abduction/adduction task (HFT) and knee extension/flexion task (KFT). Three-dimensional motion analysis systems were attached to the left gluteus medius and quadriceps, and surface electromyography was used to analyze the lower limb kinematics, kinetics, and muscle activity. The primary effects and interactions of the task and fatigue were identified based on the two-way repeated-measures analysis of variance. The results of the average angle during landing indicated that DKV occurs in KFT, whereas HFT applies external forces that adduct and internally rotate the knee at peak vertical ground reaction force (vGRF). Furthermore, both KFT and HFT exhibited an increase in muscle activity in the quadriceps. The analysis revealed that the occurrence of DKV varies depending on the peripheral fatigue task, and the effects on average DKV during landing and DKV at peak vGRF vary depending on the peripheral fatigue task.


Assuntos
Lesões do Ligamento Cruzado Anterior , Perna (Membro) , Humanos , Masculino , Fenômenos Biomecânicos , Extremidade Inferior/fisiologia , Músculo Esquelético/fisiologia , Articulação do Joelho/fisiologia
17.
BMC Musculoskelet Disord ; 25(1): 318, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38654258

RESUMO

BACKGROUND: Non-contact anterior cruciate ligament (ACL) injuries are a major concern in sport-related activities due to dynamic knee movements. There is a paucity of finite element (FE) studies that have accurately replicated the knee geometry, kinematics, and muscle forces during dynamic activities. The objective of this study was to develop and validate a knee FE model and use it to quantify the relationships between sagittal plane knee kinematics, kinetics and the resulting ACL strain. METHODS: 3D images of a cadaver knee specimen were segmented (bones, cartilage, and meniscus) and meshed to develop the FE model. Knee ligament insertion sites were defined in the FE model via experimental digitization of the specimen's ligaments. The response of the model was validated against multiple physiological knee movements using published experimental data. Single-leg jump landing motions were then simulated on the validated model with muscle forces and kinematic inputs derived from motion capture and rigid body modelling of ten participants. RESULTS: The maximum ACL strain measured with the model during jump landing was 3.5 ± 2.2%, comparable to published experimental results. Bivariate analysis showed no significant correlation between body weight, ground reaction force and sagittal plane parameters (such as joint flexion angles, joint moments, muscle forces, and joint velocity) and ACL strain. Multivariate regression analysis showed increasing trunk, hip and ankle flexion angles decreases ACL strain (R2 = 90.04%, p < 0.05). CONCLUSIONS: Soft landing decreases ACL strain and the relationship could be presented through an empirical equation. The model and the empirical relation developed in this study could be used to better predict ACL injury risk and prevention strategies during dynamic activities.


Assuntos
Lesões do Ligamento Cruzado Anterior , Ligamento Cruzado Anterior , Humanos , Ligamento Cruzado Anterior/fisiologia , Fenômenos Biomecânicos/fisiologia , Masculino , Lesões do Ligamento Cruzado Anterior/fisiopatologia , Lesões do Ligamento Cruzado Anterior/prevenção & controle , Lesões do Ligamento Cruzado Anterior/etiologia , Articulação do Joelho/fisiologia , Cadáver , Simulação por Computador , Análise de Elementos Finitos , Adulto , Feminino , Movimento/fisiologia , Adulto Jovem , Pessoa de Meia-Idade , Estresse Mecânico , Músculo Esquelético/fisiologia , Modelos Biológicos
18.
BMC Musculoskelet Disord ; 25(1): 268, 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38582828

RESUMO

BACKGROUND: Knee osteoarthritis (KOA) is a prevalent and debilitating condition that markedly affects the sit-to-stand (STS) activity of patients, a prerequisite for daily activities. Biomechanical recognition of movements in patients with mild KOA is currently attracting attention. However, limited studies have been conducted solely on the observed differences in sagittal plane movement and muscle activation. AIM: This study aimed to identify three-dimensional biomechanical and muscle activation characteristics of the STS activity in patients with mild KOA. METHODS: A cross-sectional study was conducted to observe the differences between patients with mild KOA and a control group (CG). It was conducted to observe the differences in muscle activation, including root mean square (RMS%) and integrated electromyography (items), kinematic parameters like range of motion (ROM) and maximum angular velocity, as well as dynamic parameters such as joint moment and vertical ground reaction force (vGRF). RESULTS: Patients with mild KOA had a higher body mass index and longer task duration. In the sagittal plane, patients with KOA showed an increased ROM of the pelvic region, reduced ROM of the hip-knee-ankle joint, and diminished maximum angular velocity of the knee-ankle joint. Furthermore, patients with KOA displayed increased knee-ankle joint ROM in the coronal plane and decreased ankle joint ROM in the horizontal plane. Integrated vGRF was higher in both lower limbs, whereas the vGRF of the affected side was lower. Furthermore, patients showed a decreased peak adduction moment (PADM) and increased peak external rotation moment in the knee joint and smaller PADM and peak internal rotation moment in the ankle joint. The affected side exhibited decreased RMS% and iEMG values of the gluteus medius, vastus medialis, and vastus lateralis muscles, as well as a decreased RMS% of the rectus femoris muscle. Conversely, RMS% and iEMG values of the biceps femoris, lateral gastrocnemius, and medial gastrocnemius muscles were higher. CONCLUSION: The unbalanced activation characteristics of the anterior and posterior muscle groups, combined with changes in joint moment in the three-dimensional plane of the affected joint, may pose a potential risk of injury to the irritated articular cartilage.


Assuntos
Osteoartrite do Joelho , Humanos , Osteoartrite do Joelho/diagnóstico , Fenômenos Biomecânicos , Estudos Transversais , Extremidade Inferior/fisiologia , Músculo Esquelético/fisiologia , Articulação do Joelho/fisiologia , Eletromiografia
19.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 41(2): 328-334, 2024 Apr 25.
Artigo em Chinês | MEDLINE | ID: mdl-38686414

RESUMO

Superficial cartilage defect is an important factor that causes osteoarthritis. Therefore, it is very important to investigate the influence of superficial cartilage defects on its surface morphology and mechanical properties. In this study, the knee joint cartilage samples of adult pig were prepared, which were treated by enzymolysis with chymotrypsin and physical removal with electric friction pen, respectively. Normal cartilage and surface treated cartilage were divided into five groups: control group (normal cartilage group), chymotrypsin immersion group, chymotrypsin wiping group, removal 10% group with electric friction pen, and removal 20% group with electric friction pen. The surface morphology and structure of five groups of samples were characterized by laser spectrum confocal microscopy and environmental field scanning electron microscopy, and the mechanical properties of each group of samples were evaluated by tensile tests. The results show that the surface arithmetic mean height and fracture strength of the control group were the smallest, and the fracture strain was the largest. The surface arithmetic mean height and fracture strength of the removal 20% group with electric friction pen were the largest, and the fracture strain was the smallest. The surface arithmetic mean height, fracture strength and fracture strain values of the other three groups were all between the above two groups, but the surface arithmetic mean height and fracture strength of the removal 10% group with electric friction pen, the chymotrypsin wiping group and the chymotrypsin soaking group decreased successively, and the fracture strain increased successively. In addition, we carried out a study on the elastic modulus of different groups, and the results showed that the elastic modulus of the control group was the smallest, and the elastic modulus of the removal 20% group with electric friction pen was the largest. The above study revealed that the defect of the superficial area of cartilage changed its surface morphology and structure, and reduced its mechanical properties. The research results are of great significance for the prevention and repair of cartilage injury.


Assuntos
Cartilagem Articular , Animais , Suínos , Cartilagem Articular/fisiologia , Propriedades de Superfície , Fenômenos Biomecânicos , Articulação do Joelho/fisiologia , Estresse Mecânico , Resistência à Tração , Quimotripsina/metabolismo , Microscopia Eletrônica de Varredura
20.
J Strength Cond Res ; 38(5): 825-834, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38595263

RESUMO

ABSTRACT: Johansson, DG, Marchetti, PH, Stecyk, SD, and Flanagan, SP. A biomechanical comparison between the safety-squat bar and traditional barbell back squat. J Strength Cond Res 38(5): 825-834, 2024-The primary objectives for this investigation were to compare the kinematic and kinetic differences between performing a parallel back squat using a traditional barbell (TB) or a safety-squat bar (SSB). Fifteen healthy, recreationally trained male subjects (23 + 4 years of age) performed the back squat with a TB and an SSB at 85% of their respective 1 repetition maximum with each barbell while instrumented for biomechanical analysis. Standard inverse dynamics techniques were used to determine joint kinematic and kinetic measures. A 2 × 3 (exercise × joint) factorial analysis of variance with repeated measures was used to determine the kinetic and kinematic differences between the squats while using the different barbells. Fisher's least significant difference post hoc comparisons showed that the TB resulted in significantly greater maximum hip flexion angle (129.33 ± 11.8° vs. 122.11 ± 12.1°; p < 0.001; d = 1.80), peak hip net joint extensor torque (2.54 ± 0.4 Nm·kg -1 vs. 2.40 ± 0.4 Nm·kg -1 ; p = 0.001; d = 1.10), hip net extensor torque mechanical energy expenditure (MEE; 2.81 ± 0.5 Nm·kg -1 vs. 2.58 ± 0.6 Nm·kg -1 ; p = 0.002; d = 0.97), and ankle net joint plantar flexor torque MEE (0.32 ± 0.09 J·kg -1 vs. 0.28 ± 0.06 J·kg -1 ; p = 0.029; d = 0.63), while also lifting significantly (123.17 ± 20.8 kg vs. 117.17 ± 20.8 kg; p = 0.005; d = 0.858) more weight than the SSB. The SSB resulted in significantly higher maximum knee flexion angles (116.82 ± 5.8° vs. 115.65 ± 5.6°; p = 0.011; d = 0.75) than the TB, with no significant difference in kinetics at the knee. The TB may be preferred to the SSB for developing the hip extensors and lifting higher maximum loads. The SSB may be advantageous in situations where a more upright posture or a lower load is preferred while creating a similar demand for the knee joint.


Assuntos
Articulação do Joelho , Humanos , Masculino , Fenômenos Biomecânicos , Adulto Jovem , Adulto , Articulação do Joelho/fisiologia , Articulação do Quadril/fisiologia , Torque , Levantamento de Peso/fisiologia , Músculo Esquelético/fisiologia , Articulação do Tornozelo/fisiologia , Treinamento Resistido/métodos , Amplitude de Movimento Articular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...