Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 573
Filtrar
1.
J Orthop Surg Res ; 17(1): 95, 2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-35168632

RESUMO

BACKGROUND: In treatment of chronic acromioclavicular (AC) joint dislocations, both the Weaver-Dunn procedure (WD) and CC ligament reconstruction (CCR) are recommended options due to the low possibility of healing of the coracoclavicular (CC) ligaments. The aim of this review was to determine whether CCR will yield favorable clinical and radiographic outcomes in the treatment of chronic AC dislocations. METHOD: The Cochrane Library, EMBASE, and PubMed databases were searched for literature on chronic AC dislocations from data inception to June 30, 2021. Patient data were pooled using standard meta-analytic approaches. The Cochrane-Mantel-Haenszel method and variance-weighted means were used to analyze the outcomes. The Review Manager version 5.3 software (The Nordic Cochrane Centre, The Cochrane Collaboration, Copenhagen, Denmark) was used to calculate the heterogenicity, mean difference, and relative risk (RR) for all outcomes in the meta-analysis. RESULTS: The current analysis included four trials on this topic, and all AC joint dislocations were classified as Rockwood types III to VI. The pooled data showed that the CCR group had significantly better post-operative American Shoulder and Elbow Surgeons Shoulder (ASES) scores, Oxford Shoulder Scores (OSSs), and Nottingham Clavicle Scores (NCSs) than the WD group, with a significant difference (p < 0.001, p = 0.020, and p < 0.001, respectively). In terms of the post-operative Constant-Murley Scores (CMSs), there were no significant differences between the CCR group and the WD group (p = 0.100). The CCR group had significantly better post-operative abduction and flexion of the index shoulder than the WD group (p < 0.001 and p < 0.001, respectively). In terms of radiological outcomes, the post-operative coracoclavicular distance (CCD) with a 10 kg load was smaller in the CCR group compared to that in the WD group (p < 0.001). The overall surgical wound infection rate was 11.6% in the WD group and 12.9% in the CCR, respectively (p = 0.82). CONCLUSION: The CCR group had better clinical outcome scores in the ASES, OOS, NCS, abduction, flexion, and external rotation than the WD group. In terms of radiological outcomes, the CCR group showed less displacement in weight-loaded post-CCD than the WD group, which indicated that the CCR provided more stability and resistance to deformation forces.


Assuntos
Articulação Acromioclavicular/cirurgia , Artroplastia/instrumentação , Luxações Articulares/cirurgia , Ligamentos Articulares/cirurgia , Procedimentos Ortopédicos/métodos , Procedimentos de Cirurgia Plástica/métodos , Articulação Acromioclavicular/diagnóstico por imagem , Articulação Acromioclavicular/lesões , Clavícula/cirurgia , Humanos , Luxações Articulares/diagnóstico por imagem , Ligamentos Articulares/lesões , Luxação do Ombro/diagnóstico por imagem , Luxação do Ombro/cirurgia , Resultado do Tratamento
2.
Plast Reconstr Surg ; 148(6): 946e-958e, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34847116

RESUMO

BACKGROUND: Growing use of pyrocarbon implants in upper extremity arthroplasty has culminated in a breadth of literature ascertaining outcomes and complications at long-term follow-up. However, at present, the literature remains devoid of studies synthesizing the available evidence for upper extremity surgeons to adequately assess the safety and utility of these implants relative to other available options. METHODS: A systematic search of the National Library of Medicine, MEDLINE, and Embase databases was performed to determine clinical outcomes and complication and reoperation rates following pyrocarbon arthroplasties in the upper extremity. A breakdown of complication and reoperation rates for each independent joint (shoulder, elbow, wrist, and hand joints), and according to specific causes necessitating surgery, was also compiled. RESULTS: A comprehensive summary of functional outcomes following upper extremity pyrocarbon arthroplasties is presented. Overall complication and reoperation rates in the hand and wrist were determined to be 28.2 percent and 17 percent, respectively. The proximal interphalangeal joint was associated with the highest complication rate (42.7 percent), followed by carpometacarpal joint (18.8 percent), metacarpophalangeal joint (17.6 percent), wrist (16 percent), elbow (15.7 percent), and shoulder (12.9 percent). In the hand and wrist, major complications included dislocations and subluxations (8.4 percent), stiffness and limited motion (4.4 percent), deformity (3.1 percent), hardware failure (1.9 percent), fractures (1.7 percent), persistent pain (1.7 percent), and infections (0.9 percent). CONCLUSION: In the absence of large clinical trials, systematic reviews such as these can help inform clinical guidelines and provide practitioners with an evidence-based reference to improve informed consent.


Assuntos
Artroplastia/efeitos adversos , Materiais Biocompatíveis/efeitos adversos , Carbono/efeitos adversos , Prótese Articular/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Artroplastia/instrumentação , Artroplastia/legislação & jurisprudência , Humanos , Consentimento Livre e Esclarecido , Complicações Pós-Operatórias/etiologia , Reoperação/estatística & dados numéricos , Resultado do Tratamento , Extremidade Superior/cirurgia
3.
Medicine (Baltimore) ; 100(6): e23989, 2021 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-33578516

RESUMO

BACKGROUND: It is unclear whether stemless shoulder prosthesis lead to better clinical outcomes than conventional stemmed shoulder prosthesis. The purpose is to compare clinical outcomes and complication rates after surgery in patients with shoulder arthropathy treated with stemless or conventional stemmed shoulder prosthesis. METHOD: All studies comparing the constant score (CS), range of motion (ROM), and complication rates after surgery in patients with shoulder arthropathy treated with stemless or conventional stemmed shoulder prosthesis were included. The major databases MEDLINE, EMBASE, the Cochrane Library, Web of Science, and SCOPUS were searched for appropriate studies from the earliest available date of indexing through March 31, 2019. No restrictions were placed on language of publication. RESULTS: A total of 6 studies met the inclusion criteria and were analyzed in detail. Overall postoperative ROM (95% CI: 3.27 to 11.92; P < .01) was significantly greater for stemless prosthesis compared to conventional stemmed prosthesis. However, postoperative CS (95% CI: -2.98 to 7.13; P = .42) and complication rates (OR 1.22, 95% CI: 0.48-3.08; P = .68) were did not differ significantly between the 2 groups. CONCLUSION: This meta-analysis revealed that postoperative CS and complication rates did not differ significantly between the 2 treatment methods, stemless shoulder prosthesis and conventional stemmed shoulder prosthesis, for shoulder arthropathy. However, stemless shoulder prosthesis resulted in better outcomes than conventional stemmed shoulder prosthesis in terms of postoperative ROM. LEVEL OF EVIDENCE: Level III, Therapeutic study.


Assuntos
Artroplastia/instrumentação , Artropatias/cirurgia , Articulação do Ombro/cirurgia , Prótese de Ombro/efeitos adversos , Idoso , Artroplastia/métodos , Artroplastia/estatística & dados numéricos , Gerenciamento de Dados , Humanos , Estudos Observacionais como Assunto , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/fisiopatologia , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Amplitude de Movimento Articular/fisiologia , Articulação do Ombro/patologia , Prótese de Ombro/tendências , Resultado do Tratamento
4.
Jt Dis Relat Surg ; 32(1): 101-107, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33463424

RESUMO

OBJECTIVES: This study aims to compare metal suture anchors and all-suture anchors clinically and radiologically in arthroscopic Bankart repair. PATIENTS AND METHODS: In this retrospective study, 67 patients (61 males, 6 females; mean age 26.0±5.8; range, 18 to 43 years) who underwent arthroscopic Bankart repair between April 2009 and October 2016 were divided into two groups depending on the type of the suture anchor used in different periods. Group A comprised 32 patients with arthroscopic Bankart repair performed with metal suture anchors, and Group B comprised 35 patients with arthroscopic Bankart repair performed with all-suture anchors. The patients were clinically evaluated using Rowe scores, Constant scores, redislocation rates, and positive apprehension test rates. Radiographic evaluation was performed using the Samilson-Prieto classification to observe the development of glenohumeral osteoarthritis. RESULTS: The mean follow-up period was 41.1±10.4 (range, 30 to 60) months in Group A, and 39.6±9.4 (range, 28 to 60) months in Group B, with no significant difference between the two groups (p=0.559). No significant difference was observed between Group A and Group B in terms of mean Rowe score (89.2±13.8 [range, 40 to 100] vs. 88.7±16.9 [range, 25 to 100]; p=0.895) or Constant score (87.2±8.9 [range, 48 to 96] vs. 86.9±9.0 [range, 46 to 96]; p=0.878), which were the clinical outcomes at the final follow-up examination. Postoperative redislocation rates (3.1% vs. 2.9%, p=1.0) and positive apprehension test rates (6.3% vs. 8.6%, p=1.0) were found to be similar in both groups. According to the Samilson-Prieto classification, there was no evidence of glenohumeral osteoarthritis in any of the patients in either group. CONCLUSION: Satisfactory outcomes were obtained with the use of all-suture anchors in arthroscopic Bankart repair for traumatic anterior shoulder instability. All-suture anchors and metal suture anchors, have similar outcomes in the mid-term and all-suture anchors are a reliable and effective option for arthroscopic Bankart repair.


Assuntos
Artroplastia/instrumentação , Artroscopia/instrumentação , Instabilidade Articular/cirurgia , Luxação do Ombro/complicações , Âncoras de Sutura , Adolescente , Adulto , Feminino , Humanos , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/etiologia , Masculino , Recidiva , Estudos Retrospectivos , Luxação do Ombro/diagnóstico por imagem , Luxação do Ombro/cirurgia , Resultado do Tratamento , Adulto Jovem
5.
Jt Dis Relat Surg ; 32(1): 108-114, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33463425

RESUMO

OBJECTIVES: This study aims to compare clinical results of repair using two versus three double-loaded suture anchors in arthroscopic Bankart repair. PATIENTS AND METHODS: Between July 2012 and December 2017, a total of 40 patients (38 males, 2 females; mean age: 31.6±8.1; range: 17 to 47 years) who underwent Bankart arthroscopic surgery and were followed for minimum two years were retrospectively analyzed. Group 1 (n=17) underwent arthroscopic Bankart repair with two double-loaded suture anchors, while Group 2 (n=23) underwent repair with three double-loaded suture anchors. Clinical outcomes of the patients and recurrences were compared. RESULTS: At the final postoperative follow-up, a significant improvement was observed in the functional outcomes in all patients. No statistically significant difference was found (p>0.05) in the mean clinical scores of the Constant Shoulder Score between Group 1 (94.2±7.8) and Group 2 (95.4±4.1). There was no significant difference in the mean Rowe scores (Group 1: 95.6±4.6 vs. Group 2: 96.3±3.8, respectively) and external rotation loss (at neutral Group 1: 1.9° vs. Group 2: 2.2°, respectively). Three of our patients had recurrent dislocation during a major traumatic event (n=2 in Group 1 and n=1 in Group 2). CONCLUSION: Our study results suggest that stability is not correlated with the use of either two versus three double-loaded suture anchors in arthroscopic Bankart repairs.


Assuntos
Artroplastia/instrumentação , Artroscopia/instrumentação , Instabilidade Articular/cirurgia , Luxação do Ombro/cirurgia , Âncoras de Sutura , Adolescente , Adulto , Artroplastia/métodos , Artroscopia/métodos , Feminino , Humanos , Instabilidade Articular/etiologia , Masculino , Amplitude de Movimento Articular , Recidiva , Estudos Retrospectivos , Luxação do Ombro/complicações , Luxação do Ombro/fisiopatologia , Resultado do Tratamento , Adulto Jovem
6.
Arch Orthop Trauma Surg ; 141(3): 535-541, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33492431

RESUMO

INTRODUCTION: Osteoarthritis of the first carpometacarpal joint is a common degenerative disease and surgical treatment includes resection suspension interposition arthroplasty (RSIA) with or without temporary transfixation of the first metacarpal. One major drawback includes proximalization of the first metacarpal during the postoperative course. Specific data comparing different transfixation techniques in this context is sparse. MATERIALS AND METHODS: In this retrospective study, we measured the trapezial space ratio (TSR) in 53 hands before and after RSIA to determine the proximalization of the first metacarpal depending on the type of Kirschner (K)-wire transfixation. We, therefore, compared transfixation of the first metacarpal to the scaphoid with one K-wire (1K) to transfixation of the first metacarpal with two K-wires (2K), either to the carpus (2Ka), or to the second metacarpal (2Kb), or to both second metacarpal and carpus (2Kc). RESULTS: While preoperative TSR did not differ between group 1K and 2K (p = 0.507), postoperative TSR was significantly higher in group 2K compared to 1K (p = 0.003). Comparing subgroups, postoperative TSR was significantly higher in group 2Kc than 1K (p = 0.046), while we found no significant difference comparing either group 2Ka or 2Kb to 1K (p = 0.098; p = 0.159). Neither did we find a significant difference within 2K subgroups, comparing group 2Ka and 2Kb (p = 0.834), 2Ka and 2Kc (p = 0.615), or 2Kb and 2Kc (p = 0.555). CONCLUSIONS: The results of our study suggest that transfixation with two K-wires should be preferred to transfixation with one K-wire after RSIA. Specifically, transfixation from first to second metacarpal and from first metacarpal to carpus resulted in least proximalization of the first metacarpal postoperatively.


Assuntos
Artroplastia , Fios Ortopédicos , Ossos Metacarpais/cirurgia , Artroplastia/instrumentação , Artroplastia/métodos , Articulações Carpometacarpais/cirurgia , Humanos , Osteoartrite/cirurgia , Estudos Retrospectivos
7.
Knee Surg Sports Traumatol Arthrosc ; 29(7): 2152-2158, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32754864

RESUMO

PURPOSE: To evaluate with computed tomography (CT) the incidence of anchor-related osteolysis after implantation of two types of all-suture anchors for the management of labral lesions in shoulder instability. METHODS: Single-cohort, observational study with 12-month follow-up. Thirty-three participants (27 males/6 females; age 38.3 years [SD 11.3]) with anterior labral lesions in which 143 all-suture anchors (71 Iconix 1.4 mm and 72 Suturefix 1.7 mm) were implanted were evaluated with a CT performed a mean of 15.4 [3.85] months after surgery. The volume of the bone defects was measured in the CT. Every anchor was classified into one of four groups: (1) no bone defect. (2) Partial bone defect (defects smaller than the drill used for anchor placement). (3) Tunnel enlargement (defects larger than the drill volume but smaller than twice that volume). (4) Cystic lesion (defects larger than twice the drill volume). RESULTS: No bone defect was identified in 16 anchors (11.2%, [95% CI 6.5-17.5%]). A partial bone defect was found in 84 anchors (58.7% [50.2-66.9%]). Tunnel enlargement was found in 43 anchors (30.11% [22.6-37.6%]). No anchor caused cystic lesions (0% [0-2.5%]). The defect volume was a mean of 27.8 mm3 (SD 18.4 mm3, minimum 0 mm3, maximum 94 mm3). Neither the position in the glenoid nor the type of implant used had a significant effect in the type or size of the defects. CONCLUSION: When using all-suture anchors in the glenoid during instability surgery, relevant bone osteolytic defects are rare at 1-year follow-up. Most anchor insertion tunnels will fill completely (11%) or partially (59%) with bone. Tunnel enlargement will develop in 30% of anchors. No cystic defects larger than 0.125 cm3 were observed. There is a low risk that all-suture anchors cause significant osteolytic bone defects in the glenoid. These implants can be used safely. Level of evidence IV.


Assuntos
Artroplastia/efeitos adversos , Artroscopia/efeitos adversos , Instabilidade Articular/cirurgia , Osteólise/etiologia , Osteólise/prevenção & controle , Articulação do Ombro/cirurgia , Âncoras de Sutura/efeitos adversos , Adulto , Artroplastia/instrumentação , Artroplastia/métodos , Artroscopia/instrumentação , Artroscopia/métodos , Tomografia Computadorizada de Feixe Cônico , Feminino , Humanos , Instabilidade Articular/diagnóstico por imagem , Masculino , Complicações Pós-Operatórias/prevenção & controle , Escápula/cirurgia , Articulação do Ombro/diagnóstico por imagem
8.
Orthopedics ; 44(1): e148-e150, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33002173

RESUMO

A 73-year-old woman with significant medical comorbidities presented with a grade I open left ankle fracture dislocation. Distraction arthroplasty was used as a definitive treatment for this injury. The patient tolerated the procedure and had no postoperative complications. The external fixator was removed at 6 months. The patient maintained good ankle function at the 1-year postoperative visit. Distraction arthroplasty is a viable acute and definitive treatment option for ankle fracture in patients with significant medical comorbidities. [Orthopedics. 2021;44(1):e148-e150.].


Assuntos
Fraturas do Tornozelo/cirurgia , Artroplastia/métodos , Fratura-Luxação/cirurgia , Fraturas Expostas/cirurgia , Idoso , Articulação do Tornozelo/fisiopatologia , Articulação do Tornozelo/cirurgia , Artroplastia/instrumentação , Fixadores Externos , Feminino , Humanos
9.
J Orthop Surg Res ; 15(1): 298, 2020 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-32762703

RESUMO

BACKGROUND: The purpose of this meta-analysis was to evaluate the diagnostic value of D-dimer in detecting periprosthetic joint infection (PJI). METHODS: A systematic search and screening of relevant studies was performed in the databases PubMed, Web of Science, and Embase using the following medical subject headings (MeSH) or keywords: "arthroplasty or joint prosthesis or joint replacement or periprosthetic joint or prosthetic joint", "infection or infectious or infected", and "D-dimer or serum D-dimer or plasma D-dimer or fibrin degradation products". Data were subsequently analysed and processed using Meta-Disc. RESULTS: Seven studies with 1285 patients were included in this meta-analysis. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 0.75 (95% confidence interval [CI] 0.70-0.79), 0.69 (95% CI 0.66-0.72), 3.01 (95% CI 1.84-4.93), 0.32 (95% CI 0.19-0.53), and 10.20 (95% CI 3.63-28.64), respectively. Subgroup analyses showed that the use of serum D-dimer had better sensitivity and specificity than plasma D-dimer for the diagnosis of PJI. CONCLUSIONS: Serum D-dimer was shown to have a better diagnostic value than plasma D-dimer for the diagnosis of PJI. Further research is required for clarification.


Assuntos
Produtos de Degradação da Fibrina e do Fibrinogênio/análise , Prótese Articular/microbiologia , Plasma/metabolismo , Infecções Relacionadas à Prótese/diagnóstico , Soro/metabolismo , Artroplastia/instrumentação , Sedimentação Sanguínea , Proteína C-Reativa/metabolismo , Diagnóstico Precoce , Produtos de Degradação da Fibrina e do Fibrinogênio/metabolismo , Humanos , Prótese Articular/efeitos adversos , Infecções Relacionadas à Prótese/sangue , Sensibilidade e Especificidade
10.
Acta Orthop Traumatol Turc ; 54(4): 372-377, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32812873

RESUMO

OBJECTIVE: This study aimed to radiologically assess the relationship between the tilt angle of the bipolar radial head prostheses and radiocapitellar instability. METHODS: In this radiological study, 28 consecutive patients (13 females and 15 males: mean age=47 years and age range=23-77 years) who underwent cemented bipolar radial head arthroplasty (Judet CRF II) because of comminuted radial head fracture with elbow instability were retrospectively reviewed. RESULTS: There was excellent intra- and interobserver reliability for the measurements of the tilt angle and the radiocapitellar distance. ICC for interobserver reliability of the tilt angle was 0.93, and ICC for intraobserver reliability for the 2 observers was 0.96 and 0.97, respectively. ICC for interobserver reliability of the radiocapitellar distance was 0.87, and ICC for intraobserver reliability for the 2 observers was 0.91 and 0.93, respectively. The mean tilt angle was 17.6° (range=1°-35°), and the mean radiocapitellar distance was 8 mm (range=1-17 mm). Pearson's correlation revealed a strong significant positive correlation between the tilt angle and the radiocapitellar distance (r=0.77 and p<0.001). CONCLUSION: Evidence from this study has demonstrated a strong positive correlation between the tilt angle of bipolar radial head prostheses and radiocapitellar instability. The tilt angle can be used as an indicator of radiocapitellar joint instability following bipolar radial head prostheses. LEVEL OF EVIDENCE: Level IV, Diagnostic study.


Assuntos
Artroplastia , Prótese de Cotovelo/efeitos adversos , Instabilidade Articular , Complicações Pós-Operatórias/diagnóstico , Radiografia/métodos , Fraturas do Rádio/cirurgia , Rádio (Anatomia) , Artroplastia/efeitos adversos , Artroplastia/instrumentação , Artroplastia/métodos , Transtorno Bipolar/cirurgia , Articulação do Cotovelo/fisiopatologia , Articulação do Cotovelo/cirurgia , Feminino , Fraturas Cominutivas/cirurgia , Humanos , Instabilidade Articular/diagnóstico , Instabilidade Articular/etiologia , Instabilidade Articular/prevenção & controle , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Rádio (Anatomia)/diagnóstico por imagem , Rádio (Anatomia)/lesões , Rádio (Anatomia)/cirurgia , Reprodutibilidade dos Testes , Estudos Retrospectivos
11.
Acta Orthop ; 91(6): 782-788, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32691656

RESUMO

Background and purpose - Biological patches can be used to augment rotator cuff tendon repair in an attempt to improve healing and reduce rates of re-rupture. However, little is known about the in vivo tissue response to these patches. We assessed native rotator cuff tissue response after surgical repair and augmentation with 2 commercially available extracellular matrix (ECM) patches. Patients and methods - Patients underwent a rotator cuff repair augmented with either GraftJacket (Wright Medical), Permacol (Zimmer Biomet), or no patch (Control), applied using an onlay technique. A sample of supraspinatus tendon was collected intraoperatively and 4 weeks post-surgery, using ultrasound-guided biopsy. Histology and immunohistochemistry were performed on all samples. Results - The Permacol group (n = 3) and GraftJacket group (n = 4) demonstrated some changes in native tendon ECM compared with the control group (n = 3). Significant disruption of the extracellular matrix of the repaired native supraspinatus, underlying both patches, was observed. The patches did not generally increase cellularity, foreign body giant cell count, or vascularity compared to the control group. 1 patient in the Permacol group had an adverse tissue immune response characterized by extensive infiltration of IRF5+, CD68+, and CD206+ cells, suggesting involvement of macrophages with a pro-inflammatory phenotype. No significant differences in protein expression of CD4, CD45, CD68, CD206, BMP7, IRF5, TGFß, and PDPN were observed among the groups. Interpretation - Histological and immunohistochemical analysis of native tendon tissue after patch augmentation in rotator cuff repair raises some concerns about a lack of benefit and potential for harm from these materials.


Assuntos
Artroplastia , Colágeno , Biópsia Guiada por Imagem/métodos , Inflamação , Teste de Materiais/métodos , Lesões do Manguito Rotador/cirurgia , Manguito Rotador , Artroplastia/efeitos adversos , Artroplastia/instrumentação , Artroplastia/métodos , Materiais Biocompatíveis/efeitos adversos , Materiais Biocompatíveis/uso terapêutico , Colágeno/efeitos adversos , Colágeno/uso terapêutico , Feminino , Reação a Corpo Estranho/etiologia , Reação a Corpo Estranho/imunologia , Reação a Corpo Estranho/patologia , Humanos , Inflamação/etiologia , Inflamação/imunologia , Inflamação/patologia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Avaliação de Processos e Resultados em Cuidados de Saúde , Manguito Rotador/irrigação sanguínea , Manguito Rotador/imunologia , Ultrassonografia/métodos , Reino Unido , Cicatrização/imunologia
12.
Biomed Mater ; 15(5): 055027, 2020 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-32498062

RESUMO

A mini or partial arthroplasty may offer the advantages of reduced pain, shorter hospital stay, and increased range of motion, which are beneficial for the treatment of large-sized focal osteochondral defects. We aimed to evaluate the in vivo histologic response and function of our nonresorbable, composite structure implant, developed using polyetheretherketone (PEEK) and Ti6AI4V alloy, as a treatment for full-thickness osteochondral defects in the femoral head of the hip using a goat model. The gross and imaging appearance and histologic results were compared to those of a similar size cobalt-chromium-molybdenum (CoCrMo) alloy implant placed in a defect in the femoral head and evaluated up to 12 weeks. The X radiographs showed that there was no evidence of loosening of the implants for both the PEEK-Ti6AI4V and CoCrMo groups. Magnetic resonance imaging results showed no inflammatory signal findings in both PEEK-Ti6AI4V and CoCrMo implants. Macroscopically and histologically, there was lesser cartilage degeneration in the PEEK-Ti6AI4V implant than in the CoCrMo implant. The modified macroscopic articular evaluation score was lower in the PEEK-Ti6AI4V group than in the CoCrMo group (p < 0.05), and the histological score of the periprosthetic and acetabular cartilage was lower in the PEEK-Ti6AI4V group than in the CoCrMo group (P < 0.05). The micro-computed tomography results showed that the uncemented PEEK-Ti6AI4V implant has better osseointegration and higher bone-implant contact than the cemented CoCrMo implant. The peri-implant bone mass was higher in the PEEK-Ti6AI4V implant(p < 0.05). Meanwhile, the optical profile analytical results showed that the surface roughness of the cartilage in the acetabulum was higher in the CoCrMo group. In conclusion, the mini-arthroplasty implant based on PEEK-Ti6AI4V was superior to an identical CoCrMo alloy implant as a treatment for local osteochondral defect in the femoral head, owing to its in vivo cartilage protection and better osseointegration.


Assuntos
Ligas/química , Artroplastia/instrumentação , Artroplastia/métodos , Benzofenonas/química , Substitutos Ósseos , Cabeça do Fêmur/efeitos dos fármacos , Osteoblastos/efeitos dos fármacos , Polímeros/química , Titânio/química , Animais , Cartilagem Articular/efeitos dos fármacos , Cabras , Inflamação , Osseointegração , Próteses e Implantes , Propriedades de Superfície , Microtomografia por Raio-X
13.
J Orthop Surg Res ; 15(1): 36, 2020 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-32005193

RESUMO

BACKGROUND: Biomechanical characteristics of noncontinuous ACDF and noncontinuous CDA in the treatment of noncontinuous cervical degenerative disc disease were still unclear. The aim of this research is to compare the differences between these two kinds of treatment methods and to verify the effectiveness of Prodisc-C in noncontinuous CDA. METHODS: Eight FEMs of the cervical spine (C2-C7) were built based on CT images of 8 mild CDDD volunteers. In the arthroplasty group, we inserted Prodisc-C at C3/4 and C5/6. In the fusion group, CoRoent® Contour and NuVasive® Helix ACP were implanted at C3/4 and C5/6. Initial loads of 75 N were used to simulate the head weight and muscle forces. The application of 1.0 N m moment on the top on the C2 vertebra was used to create motion in all directions. Statistical analyses were performed using STATA version 14.0 (Stata Corp LP, College Station, Texas, USA). Statistical significance was set at P < 0.05. RESULTS: The IDPs in C2/3 (P < 0.001, P = 0.005, P < 0.001, P < 0.001), C4/5 (P < 0.001), and C6/7 (P < 0.001) of the intact group were significantly less than that in the fusion group in flexion, extension, lateral bending, and axial rotation, respectively. In addition, the IDPs in C2/3 (P < 0.001, P = 0.001, P < 0.001, P < 0.001), C4/5 (P < 0.001), and C6/7 (P < 0.001) of the arthroplasty group were significantly less than that in the fusion group in flexion, extension, lateral bending, and axial rotation, respectively. Contact forces of facet joints in C2/3 (P = 0.010) in the arthroplasty group was significantly less than that in the intact group. Contact forces of facet joints in C2/3 (P < 0.001), C4/5 (P < 0.001), and C6/7 (P < 0.001) in the arthroplasty group was significantly less than that in the fusion group. Contact forces of facet joints in C2/3 (P < 0.001), C4/5 (P < 0.001), and C6/7 (P < 0.001) in the intact group were significantly less than that in the fusion group. CONCLUSIONS: Noncontinuous CDA could preserve IDP and facet joint forces at the adjacent and intermediate levels to maintain the kinematics of cervical spine near preoperative values. However, noncontinuous ACDF would increase degenerative risks at adjacent and intermediate levels. In addition, the application of Prodisc-C in noncontinuous CAD may have more advantages than that of Prestige LP.


Assuntos
Artroplastia/métodos , Discotomia/métodos , Análise de Elementos Finitos , Degeneração do Disco Intervertebral/cirurgia , Disco Intervertebral/cirurgia , Fusão Vertebral/métodos , Artroplastia/instrumentação , Fenômenos Biomecânicos/fisiologia , Vértebras Cervicais/patologia , Vértebras Cervicais/cirurgia , Discotomia/instrumentação , Feminino , Humanos , Disco Intervertebral/patologia , Degeneração do Disco Intervertebral/patologia , Masculino , Modelos Anatômicos , Próteses e Implantes , Fusão Vertebral/instrumentação , Resultado do Tratamento
14.
JBJS Case Connect ; 10(1): e0378, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32044787

RESUMO

CASE: A 35-year-old man with a giant cell tumor involving the lateral condyle and trochlea of the right distal femur underwent curettage of the lesion and cement grafting, which resulted in symptomatic patellofemoral osteoarthritis after more than 4 years. A standard follow-up excluded recurrence, whereas infection was ruled out while investigating the symptoms. Finally, a patellofemoral resurfacing prosthesis was implanted while filling the bone defects with tantalum cones. CONCLUSION: A "tailored" surgical technique with a selected patellofemoral joint arthroplasty could be used in oncologic setting to save further bone stock for possible revisions while permitting full and quick clinical recovery.


Assuntos
Artroplastia/métodos , Neoplasias Femorais/cirurgia , Tumor de Células Gigantes do Osso/cirurgia , Osteoartrite do Joelho/cirurgia , Articulação Patelofemoral/cirurgia , Complicações Pós-Operatórias/cirurgia , Adulto , Artroplastia/instrumentação , Neoplasias Femorais/diagnóstico por imagem , Tumor de Células Gigantes do Osso/diagnóstico por imagem , Humanos , Masculino , Osteoartrite do Joelho/diagnóstico por imagem , Articulação Patelofemoral/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Reoperação
15.
Plast Reconstr Surg ; 145(3): 746-754, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32097319

RESUMO

Research bias, or the systematic errors of a study, can arise before, during, or after a trial ends. These biases hinder the internal validity of the study, which is the accuracy of a study's conclusions regarding the effects of an intervention on a given group of subjects. With the growing use of evidence-based medicine, there is a demand for high-quality evidence from the research community. Systematic reviews and meta-analyses of randomized controlled trials are considered the highest level of evidence, followed by individual randomized controlled trials. However, most surgical trials cannot be conducted as randomized controlled trials because of factors such as patient preferences and lack of equipoise among surgeons. Therefore, surgical trials may lack features that are held as important standards for high-quality evidence, such as randomization and blinding. To demonstrate the biases that surgical trials may encounter, the authors examined a prospective cohort study, the Silicone Arthroplasty in Rheumatoid Arthritis study. The authors focus on the challenges that arise during a surgical trial, including the design, implementation, and methods used to report the clinical evidence. By recognizing and addressing obstacles that exist in research, investigators will provide health care providers with high-quality evidence needed to make well-informed, evidence-based clinical decisions.


Assuntos
Artrite Reumatoide/cirurgia , Artroplastia/efeitos adversos , Prótese Articular/efeitos adversos , Avaliação de Resultados em Cuidados de Saúde/normas , Projetos de Pesquisa/normas , Artrite Reumatoide/epidemiologia , Artroplastia/instrumentação , Artroplastia/normas , Viés , Tomada de Decisão Clínica , Ensaios Clínicos como Assunto/normas , Medicina Baseada em Evidências/normas , Seguimentos , Humanos , Avaliação de Resultados em Cuidados de Saúde/métodos , Seleção de Pacientes , Estudos Prospectivos , Silicones/efeitos adversos
16.
BMC Musculoskelet Disord ; 21(1): 31, 2020 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-31937287

RESUMO

BACKGROUND: In highly active older individuals, end-stage ankle osteoarthritis has traditionally been treated using tibiotalar arthrodesis, which provides considerable pain relief. However, there is a loss of ankle joint movement and a risk of future arthrosis in the adjacent joints. Distraction arthroplasty is a simple method that allows joint cartilage repair; however, the results are currently mixed, with some reports showing improved pain scores and others showing no improvement. Distal tibial osteotomy (DTO) without fibular osteotomy is a type of joint preservation surgery that has garnered attention in recent years. However, to our knowledge, there are no reports on DTO with joint distraction using a circular external fixator. Therefore, the purpose of this study was to examine the effect of DTO with joint distraction using a circular external fixator for treating ankle osteoarthritis. METHODS: A total of 21 patients with medial ankle arthritis were examined. Arthroscopic synovectomy and a microfracture procedure were performed, followed by angled osteotomy and correction of the distal tibia; the ankle joint was then stabilized after its condition improved. An external fixator was used in all patients, and joint distraction of approximately 5.8 mm was performed. All patients were allowed full weight-bearing walking immediately after surgery. RESULTS: The anteroposterior and lateral mortise angle during weight-bearing, talar tilt angle, and anterior translation of the talus on ankle stress radiography were improved significantly (P < 0.05). Signal changes on magnetic resonance imaging also improved in all patients. Visual analog scale and American Orthopedic Foot & Ankle Society scores improved significantly (P < 0.05), and no severe complications were observed. CONCLUSION: DTO with joint distraction may be useful as a joint-preserving surgery for medial ankle osteoarthritis in older patients with high levels of physical activity. LEVEL OF EVIDENCE: Level IV, retrospective case series.


Assuntos
Articulação do Tornozelo/cirurgia , Artroplastia/métodos , Fixadores Externos , Osteoartrite/cirurgia , Osteotomia/métodos , Idoso , Idoso de 80 Anos ou mais , Articulação do Tornozelo/diagnóstico por imagem , Artrite Reumatoide/cirurgia , Artroplastia/instrumentação , Artroscopia/métodos , Exercício Físico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Sinovectomia/métodos , Escala Visual Analógica , Suporte de Carga
17.
Foot Ankle Surg ; 26(6): 630-636, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31439504

RESUMO

BACKGROUND: The aim of this prospective study is to evaluate the results of a consecutive series of patients suffering from grade II-III hallux rigidus who underwent a mobility preserving surgical technique consisting of resection arthroplasty with implantation of a temporary metal spacer. METHODS: Thirty consecutive patients, 18 female and 12 male with a diagnosis of a grade II-III hallux rigidus, not responding to conservative treatment, underwent a minimal resection arthroplasty followed by the implantation of a temporary metal interpositional device by the same surgeon. All spacers were removed after 6 months through a minimal incision under regional anaesthesia. Patients were clinically and radiographically evaluated at 3, 6, 12 months, and 5 years after spacer removal. RESULTS: The clinical AOFAS scores improved already at first follow-up and continued to improve over time with a statistically significant change until the first year. At 3, 6, and 12 months follow-ups, the number of patients with severely limited ROM (i.e. under 30°, that means grade II-III according to Coughlin and Shaurnas classification) significantly decreased. There were only two minor complications, so defined as both of which resolved spontaneously and did not affect the procedure's effectiveness. CONCLUSIONS: We observed good to excellent results with the use of this mobility preserving surgical technique for the treatment of symptomatic grades II and III hallux rigidus. The never before published procedure is easy to perform and inexpensive. LEVEL OF EVIDENCE: Level IV.


Assuntos
Artroplastia/instrumentação , Hallux Rigidus/cirurgia , Articulação Metatarsofalângica/cirurgia , Adulto , Idoso , Remoção de Dispositivo , Feminino , Seguimentos , Hallux Rigidus/classificação , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Amplitude de Movimento Articular
18.
J Shoulder Elbow Surg ; 29(1): e11-e21, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31405714

RESUMO

BACKGROUND: Massive rotator cuff (RC) tears still present a clinically challenging problem, with reported rerupture rates in up to 94%. The study objective was to determine the impact of synthetic patch augmentation for massive RC tears. METHODS: Between June 2012 and 2014, we performed 50 arthroscopic RC reconstructions augmented with a synthetic polyester patch. Pre- and postoperative imaging methods included arthrographic magnetic resonance imaging, arthrographic computed tomography, and ultrasound examination to determine tendon integrity or rerupture. Clinical outcome was evaluated using the Constant-Murley score and the subjective shoulder value. Mean clinical midterm and final follow-up was 22 months (9-35 months) and 52 months (25-74 months), respectively. RESULTS: The mean Constant-Murley score increased significantly from 36.5 (±16.4 standard deviation [SD]) preoperatively to a midterm value of 81.2 (±9.6 SD; P < .0001) and further improved to a mean of 83.4 (±10.8 SD) at final follow-up. The mean subjective shoulder value increased from 40.3 (±24.3 SD) to 89.2 (±12.9 SD; P < .0001) at midterm and to 89.6 (±15.2 SD) at final follow-up. We observed 7 complete reruptures (14%). However, reruptures did not correlate with revision surgery, which was performed in 8 patients. The main reason for revision was frozen shoulder or arthrofibrosis with an intact reconstruction and patch, which was performed in 6 cases. CONCLUSIONS: The retear rate of 14% compared favorably with nonaugmented RC repairs in the literature. Therefore, we conclude that patch augmentation in massive RC tears is feasible to reduce retears and to improve clinical outcome.


Assuntos
Artroplastia/instrumentação , Próteses e Implantes , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Articulação do Ombro/cirurgia , Idoso , Artroscopia , Estudos de Coortes , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Poliésteres , Estudos Prospectivos , Recidiva , Reoperação , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/fisiopatologia , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Ultrassonografia
19.
Neurosurgery ; 86(2): 155-169, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31724719

RESUMO

Lumbar degenerative disc disease is a pathologic process that affects a large portion of our aging population. In the recent past, surgical treatment has involved fusion procedures. However, lumbar disc arthroplasty and replacement provides an alternative for carefully selected patients. It provides the major advantage of motion preservation and thus keeps adjacent segments from significantly progressive degeneration. The history of lumbar disc replacement has roots that start in the 1960s with the implantation of stainless-steel balls. Decades later, multiple implants with different material design and biomechanical properties were introduced to the market. New third-generation implants have made great strides in improved biomechanics and clinical outcomes. Although there is room for further advancement and studies are warranted to assess the long-term durability and sustainability of lumbar disc arthroplasty, it has certainly proven to be a very acceptable alternative within the surgical armamentarium that should be offered to patients who meet indications. In this review we present an overview of lumbar disc arthroplasty including its history, indications, biomechanics, challenges, and future directions.


Assuntos
Artroplastia/tendências , Degeneração do Disco Intervertebral/diagnóstico por imagem , Degeneração do Disco Intervertebral/cirurgia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Próteses e Implantes/tendências , Adulto , Idoso , Artroplastia/instrumentação , Fenômenos Biomecânicos , Feminino , Previsões , Humanos , Disco Intervertebral/diagnóstico por imagem , Disco Intervertebral/cirurgia , Masculino , Desenho de Prótese/instrumentação , Desenho de Prótese/tendências , Fusão Vertebral/métodos
20.
Clin Podiatr Med Surg ; 36(4): 577-596, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31466569

RESUMO

Evidence-based medicine continues to guide our treatment of patients. Owing to the unique characteristics of the first metatarsophalangeal joint (1st MTPJ) with its small surface area and the significant amount of multiplanar force that affects it, finding the perfect implant to allow motion and alleviate pain is still the ultimate goal. While some of the older metallic implants and silastic spacers may still be providing pain relief and function to patients, the majority have failed and caused significant bone loss along the way. The HemiCap implants have shown some promise in select patients and may still be a viable option in patients desiring maintenance of 1st MTPJ motion.


Assuntos
Artroplastia/instrumentação , Hallux , Artropatias/cirurgia , Articulação Metatarsofalângica , Próteses e Implantes , Humanos , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...