Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.572
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38722914

RESUMO

INTRODUCTION: Anatomic and reverse total shoulder arthroplasties (TSAs) are effective treatment options for end-stage glenohumeral osteoarthritis. Those undergoing TSA may also have fibromyalgia, a musculoskeletal condition. However, the association of fibromyalgia with shorter and longer term outcomes after TSA has not been well characterized. METHODS: Patients undergoing TSA for osteoarthritis indications were identified in the PearlDiver M165 database from January 2016 to October 2022. Exclusion criteria included age younger than 18 years, shoulder infection, neoplasm, or trauma within 90 days before surgery, and inactivity in the database within 90 days of surgery. Patients with fibromyalgia were matched in a 1:4 ratio to patients without based on age, sex, and Elixhauser Comorbidity Index. Ninety-day adverse events were compared using univariable and multivariable analyses. Five-year revision-free survival was compared using the log-rank test. RESULTS: Of 163,565 TSA patients, fibromyalgia was identified for 9,035 (5.52%). After matching, cohorts of 30,770 non-fibromyalgia patients and 7,738 patients with fibromyalgia were identified. Multivariable analyses demonstrated patients with fibromyalgia were at independently increased odds ratios (ORs) for the following 90-day complications (decreasing OR order): urinary tract infection (OR = 4.49), wound dehiscence (OR = 3.63), pneumonia (OR = 3.46), emergency department visit (OR = 3.45), sepsis (OR = 3.15), surgical site infection (OR = 2.82), cardiac events (OR = 2.72), acute kidney injury (OR = 2.65), deep vein thrombosis (OR = 2.48), hematoma (OR = 2.03), and pulmonary embolism (OR = 2.01) (P < 0.05 for each). These individual complications contributed to the increased odds of aggregated minor adverse events (OR = 3.68), all adverse events (OR = 3.48), and severe adverse events (OR = 2.68) (P < 0.05 for each). No statistically significant difference was observed in 5-year revision-free survival between groups. DISCUSSION: This study found TSA patients with fibromyalgia to be at increased risk of adverse events within 90 days of surgery. Proper surgical planning and patient counseling are crucial to this population. Nonetheless, it was reassuring that those with fibromyalgia had similar 5-year revision-free survival compared with those without.


Assuntos
Artroplastia do Ombro , Fibromialgia , Complicações Pós-Operatórias , Humanos , Feminino , Fibromialgia/complicações , Masculino , Complicações Pós-Operatórias/epidemiologia , Idoso , Pessoa de Meia-Idade , Osteoartrite/cirurgia , Fatores de Risco , Estudos Retrospectivos
2.
JBJS Case Connect ; 14(2)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38728442

RESUMO

CASE: A 71-year-old woman presented with post-traumatic arthritis 11 months after open reduction and internal fixation for a left proximal humerus fracture (PHF) dislocation. After revision to reverse total shoulder arthroplasty (rTSA), the patient's left upper extremity was found to be avascular. An emergent thrombectomy was performed with restoration of arterial flow after removal of an acute-on-chronic axillary artery thrombus. CONCLUSION: Although rare, as rTSA becomes more common for management of PHF, incidence of associated vascular injuries is likely to rise. Screening methods and clinical vigilance in diagnosis are advised for patients with anterior PHF dislocations and arterial injury risk factors.


Assuntos
Artroplastia do Ombro , Artéria Axilar , Fraturas do Ombro , Trombose , Humanos , Feminino , Idoso , Artéria Axilar/cirurgia , Artéria Axilar/lesões , Artéria Axilar/diagnóstico por imagem , Fraturas do Ombro/cirurgia , Fraturas do Ombro/diagnóstico por imagem , Artroplastia do Ombro/efeitos adversos , Trombose/etiologia , Trombose/diagnóstico por imagem , Trombose/cirurgia , Fixação Interna de Fraturas/efeitos adversos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/diagnóstico por imagem , Redução Aberta/efeitos adversos , Reoperação
3.
Sports Med Arthrosc Rev ; 32(1): 17-21, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38695499

RESUMO

Rotator cuff tears are the most frequent shoulder injury in patients over 50 years old. Treatment of rotator cuff tears is individualized based on the age, demands, and symptoms of the patient. Nonoperative treatment may often be effective, especially in lower-demand or elderly patients. Surgical repair is indicated after failure of nonoperative treatment or in patients whose high-demand lifestyle requires full strength and function of the shoulder. In older patients, larger tears are less likely to heal and rotator cuff repair may not reliable. In cases of failed previous rotator cuff repair, there may not be enough viable tissue for complete repair. If there is underlying arthritis, a rotator cuff repair is unlikely to resolve all symptoms, and treatment to care for the arthritis and rotator cuff tear is indicated. Reverse shoulder arthroplasty provides the surgical answer for these scenarios and is now being used for numerous indications of shoulder pathology.


Assuntos
Artroplastia do Ombro , Lesões do Manguito Rotador , Humanos , Lesões do Manguito Rotador/cirurgia , Artroplastia do Ombro/métodos
4.
Bull Hosp Jt Dis (2013) ; 82(2): 146-153, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38739663

RESUMO

Surgical management of the subscapularis tendon is critical to a successful outcome following anatomic total shoulder arthroplasty. However, the optimal surgical technique for adequate exposure of the glenohumeral joint while mini-mizing complications resulting from subscapularis tendon dysfunction continues to be controversial. Common surgical techniques for the management of the subscapularis tendon include tenotomy, peeling, sparing, and lesser tuberosity oste-otomy. Despite a number of published studies comparing these techniques, no consensus has been reached regarding optimal management. This article reviews the extensive literature on the biomechanical, radiologic, and clinical outcomes of each technique, including recently published comparison studies.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Humanos , Artroplastia do Ombro/métodos , Artroplastia do Ombro/efeitos adversos , Articulação do Ombro/cirurgia , Articulação do Ombro/fisiopatologia , Articulação do Ombro/diagnóstico por imagem , Resultado do Tratamento , Fenômenos Biomecânicos , Tenotomia/métodos , Recuperação de Função Fisiológica , Tendões/cirurgia , Amplitude de Movimento Articular
5.
J Orthop Traumatol ; 25(1): 20, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637350

RESUMO

BACKGROUND: This study aims to compare the range of motion (ROM) of reverse shoulder arthroplasty lateralised by bony increased offset (BIO-RSA) using a standard 38-mm (mm) component to regular reverse shoulder arthroplasty (RSA) lateralised by using a 42-mm glenoid component. The secondary aims are to compare patient-reported and radiographic outcomes between the two groups. MATERIALS AND METHODS: All patients with a BIO-RSA and size 38 glenosphere were retrospectively identified and matched to patients with a regular RSA and size 42 glenosphere. Matched patients were invited for a follow-up visit. ROM was assessed as well as radiographic outcomes (lateralisation, distalisation, inferior overhang, scapular notching, heterotopic bone formation, radiolucency, stress shielding, bone graft healing and viability and complications) and patient-reported outcomes (subjective shoulder value, Constant score, American Shoulder and Elbow Surgeons, activities of daily living which require internal rotation, activities of daily living which require external rotation and a visual analogue scale for pain). Outcomes were compared between the two groups. RESULTS: In total, 38 BIO-RSAs with a size 38 glenosphere were matched to 38 regular RSAs with a size 42 glenosphere. Of the 76 matched patients, 74 could be contacted and 70 (95%) were included. At the final follow-up, there were no differences between the two groups in ROM, patient-reported outcomes or radiographic outcomes (p > 0.485). CONCLUSIONS: Using a larger glenosphere is a feasible alternative to BIO-RSA for lateralising RSA, providing comparable ROM, patient-reported and radiographic results, while potentially decreasing costs, operative time and complication rates.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Humanos , Artroplastia do Ombro/métodos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Estudos Retrospectivos , Atividades Cotidianas , Escápula/diagnóstico por imagem , Escápula/cirurgia , Amplitude de Movimento Articular , Resultado do Tratamento
6.
Arch Orthop Trauma Surg ; 144(5): 2093-2099, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38653836

RESUMO

OBJECTIVE: The objective of this study was to evaluate clinical and radiological outcomes of a short stem reverse shoulder prosthesis with metaphyseal fixation specifically in older patients. METHODS: All patients, older than 70 years, submitted to a Reverse Shoulder Arthroplasty (RSA) using a cementless onlay short stem (Aequalis Ascend™ Flex Convertible Shoulder System (Stryker®)) from January 2017 to December 2021, with a minimum follow-up of 2 years, were included. Postoperative radiographs were assessed for stem loosening, subsidence, and varus-valgus tilt. Range of motion, visual analogue scale for pain, constant score, complication rate and revision rate were also analysed. RESULTS: A total of 34 patients with a mean age of 75 years (range 71-83 years) were submitted to a cementless onlay short stem RSA with a Bone Increased Off-Set (BIO-RSA) construct. The mean follow-up period was 61 months (range 54-87). Significant improvements (p < 0.001) were observed for the constant score and range of motion from the preoperative state to final follow-up. One case exhibited a significant varus deviation (> 5˚) during the follow-up period. No case of stem loosening was identified. There was only one case of complication because of post-traumatic dislocation, but the stem didn't need revision. CONCLUSION: Short stem RSA, even in patients older than 70 years, can yield a stable fixation with a good clinical and radiological outcome at short-medium term follow-up. LEVEL OF EVIDENCE: Level III; Retrospective Study.


Assuntos
Artroplastia do Ombro , Desenho de Prótese , Prótese de Ombro , Humanos , Idoso , Artroplastia do Ombro/métodos , Idoso de 80 Anos ou mais , Feminino , Masculino , Amplitude de Movimento Articular , Estudos Retrospectivos , Radiografia , Resultado do Tratamento , Articulação do Ombro/cirurgia , Articulação do Ombro/diagnóstico por imagem
7.
Acta Orthop Belg ; 90(1): 115-122, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38669660

RESUMO

The introduction of fast-track protocols decreased length of hospital stay and improved rehabilitation and outcomes in total joint arthroplasty. Despite improved clinical results published in many papers, the patient perspective of these protocols is less investigated. Purpose of this study was to explore the patient perspective of fast-track protocols in arthroplasty. A systematic search for articles of patient experiences in total hip, knee, and shoulder arthroplasty was conducted using EMBASE, MEDLINE, Cochrane, and Web-of-Science for articles published from inception to February 14, 2023. In total 12 studies were included involving 672 patients. Most patients were satisfied with short length of hospital stay and preferred rehabilitation at home with relatives for support. Various experiences were reported regarding pain and postoperative out of hospital physical therapy. Frequently, feelings of insecurity were reported because of lack of personalized information. Based on current qualitative literature, patients are satisfied with short length of hospital stay in fast-track total joint arthroplasty. Improvements in personalized information and physical therapy protocols is needed.


Assuntos
Tempo de Internação , Satisfação do Paciente , Humanos , Tempo de Internação/estatística & dados numéricos , Artroplastia de Quadril/reabilitação , Artroplastia de Quadril/métodos , Artroplastia do Joelho/reabilitação , Artroplastia do Joelho/métodos , Artroplastia de Substituição/métodos , Artroplastia do Ombro/métodos
8.
Artigo em Inglês | MEDLINE | ID: mdl-38569086

RESUMO

INTRODUCTION: This study aimed to assess the relationship between preoperative international normalized ratio (INR) levels and major postoperative bleeding events after total shoulder arthroplasty (TSA). METHODS: The American College of Surgeons National Surgical Quality Improvement Program database was queried for TSA from 2011 to 2020. A final cohort of 2405 patients with INR within 2 days of surgery were included. Patients were stratified into four groups: INR ≤ 1.0, 1.0 < INR ≤ 1.25, 1.25< INR ≤ 1.5, and INR > 1.5. The primary outcome was bleeding requiring transfusion within 72 hours, and secondary outcome variables included complication, revision surgery, readmission, and hospital stay duration. Multivariable logistic and linear regression analyses adjusted for relevant comorbidities were done. RESULTS: Of the 2,405 patients, 48% had INR ≤ 1.0, 44% had INR > 1.0 to 1.25, 7% had INR > 1.25 to 1.5, and 1% had INR > 1.5. In the adjusted model, 1.0 < INR ≤ 1.25 (OR 1.7, 95% CI 1.176 to 2.459), 1.25 < INR ≤ 1.5 (OR 2.508, 95% CI 1.454 to 4.325), and INR > 1.5 (OR 3.200, 95% CI 1.233 to 8.302) were associated with higher risks of bleeding compared with INR ≤ 1.0. DISCUSSION: The risks of thromboembolism and bleeding lie along a continuum, with higher preoperative INR levels conferring higher postoperative bleeding risks after TSA. Clinicians should use a patient-centered, multidisciplinary approach to balance competing risks.


Assuntos
Artroplastia do Ombro , Tromboembolia , Humanos , Coeficiente Internacional Normatizado/efeitos adversos , Complicações Pós-Operatórias/etiologia , Artroplastia do Ombro/efeitos adversos , Hemorragia Pós-Operatória/etiologia , Hemorragia Pós-Operatória/complicações , Tromboembolia/complicações
9.
Artigo em Inglês | MEDLINE | ID: mdl-38648447

RESUMO

INTRODUCTION: Sex disparities in presentation of osteoarthritis and utilization of joint replacement surgery (JRS) have been demonstrated. The role of patients' unique perspectives on JRS on their treatment decisions is poorly understood. METHODS: JRS candidates who were offered JRS but declined surgical treatment completed this survey. Survey questions included demographic information, patient experiences and current opinions around JRS, patient experiences with providers, goals and concerns, and barriers to JRS. RESULTS: More women experience barriers to undergoing JRS compared with men (53% versus 16%; P = 0.014). While both men and women indicated pain relief as their primary goal for treatment, women were significantly more likely to prioritize regaining the ability to complete daily tasks and responsibilities when compared with men (P = 0.007). Both men and women indicated that low symptom severity and nonsurgical treatment options were the reasons for not undergoing JRS (P = 0.455). Compared with men, women trended toward feeling that they were not sufficiently educated about JRS (P = 0.051). CONCLUSION: Women have unique perspectives and goals for JRS that may pose sex-specific barriers to care. A better understanding of how patients' gendered experiences affect their decision making is necessary to improve treatment of osteoarthritis and decrease disparities in care.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Humanos , Feminino , Masculino , Fatores Sexuais , Pessoa de Meia-Idade , Idoso , Artroplastia do Ombro , Inquéritos e Questionários , Osteoartrite do Joelho/cirurgia , Osteoartrite do Quadril/cirurgia , Osteoartrite do Quadril/psicologia , Osteoartrite/cirurgia , Osteoartrite/psicologia
10.
Clin Orthop Surg ; 16(2): 303-312, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38562639

RESUMO

Background: Glenoid position and inclination are important factors in protecting against scapular notching, which is the most common complication that directly affects the longevity of reverse shoulder arthroplasty (RSA). This study aimed to investigate the biomechanical characteristics of glenosphere orientation, comparing neutral tilt, inferior overhang with an eccentric glenosphere at the same placement of baseplate, and inferior tilt after 10° inferior reaming in the lower part of the glenoid in RSA. Methods: Nine cadaveric shoulders were tested with 5 combinations of customized glenoid components: a centric glenosphere was combined with a standard baseplate (group A); an eccentric glenosphere to provide 4-mm inferior overhang than the centric glenosphere was combined with a standard baseplate (group B); a centric glenosphere was combined with a wedge-shaped baseplate tilted inferiorly by 10° with the same center of rotation (group C); an eccentric glenosphere was attached to a wedge-shaped baseplate (group D); and 10° inferior reaming was performed on the lower part of the glenoid to apply 10° inferior tilt, with a centric glenosphere secured to the standard baseplate for simulation of clinical tilt (group E). Impingement-free angles for adduction, abduction, forward flexion, external rotation, and internal rotation were measured. The capability of the deltoid moment arm for abduction and forward flexion, deltoid length, and geometric analysis for adduction engagement were evaluated. Results: Compared with neutral tilt, inferior tilt at the same position showed no significant difference in impingement-free angle, moment arm capability, and deltoid length. However, group D resulted in better biomechanical properties than a central position, regardless of inferior tilt. Group E demonstrated a greater range of adduction, internal and external rotation, and higher abduction and forward flexion capability with distalization, compared to corresponding parameters for inferior tilt with a customized wedge-shaped baseplate. Conclusions: A 10° inferior tilt of the glenosphere, without changing the position of the baseplate, had no benefit in terms of the impingement-free angle and deltoid moment arm. However, an eccentric glenosphere had a significant advantage, regardless of inferior tilt. Inferior tilt through 10° inferior reaming showed better biomechanical results than neutral tilt due to the distalization effect.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Prótese de Ombro , Humanos , Artroplastia do Ombro/métodos , Articulação do Ombro/cirurgia , Ombro/cirurgia , Escápula , Amplitude de Movimento Articular , Fenômenos Biomecânicos
11.
Clin Orthop Surg ; 16(2): 294-302, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38562643

RESUMO

Background: There are few reports on the revision or reintervention of reverse total shoulder arthroplasty (RTSA) in South Korea. The purpose of this study was to evaluate the true incidence of complications and reintervention of RTSA and clinical and radiological outcomes based on our 14-year experience in RTSA in a Korean population. Methods: Between March 2008 and June 2022, 412 consecutive cases of RTSA were performed in 388 patients with an average age of 74.4 years at our institute. Excluding 23 patients lost to follow-up, 365 patients (373 shoulders including 8 bilateral cases) who underwent primary RTSA with more than 6 months of follow-up were enrolled in this study. We evaluated those who had complications or reintervention including revision RTSA for failed RTSA. Patient charts were reviewed, and clinical outcomes including clinical scores, complications, and reintervention and radiologic outcomes were evaluated at the last follow-up. Results: Among the 373 shoulders that underwent primary RTSA, complications were found in 50 patients (13.94%, 10 men and 40 women with a mean age of 75.9 ± 6.7 years [range, 51-87 years]). The causes of complications were as follows: 13 acromion, coracoid, or scapular spine fractures, 10 loosening (glenoid: 5, humeral stem: 5), 5 infections, 4 periprosthetic fractures, 2 instability, 2 neurologic complications, and 14 miscellaneous complications. Twenty patients (5.63%, 4 men and 16 women with a mean age of 74.2 ± 8.2 years [range, 51-87 years]) underwent reintervention. The interval to the first reintervention was 27.8 ± 23.1 months (range, 0.1-78 months). The causes of reintervention (20 cases) were 8 loosening (glenoid: 4, humeral stem: 4), 5 infections, 5 fractures, and 2 instability. Among them, 15 component revisions (4.02%) were performed. At the last follow-up, American Shoulder and Elbow Surgeons, University of California at Los Angeles, and Simple Shoulder Test scores were improved from 25.4, 12.4, and 1.6 preoperatively to 40.4, 16.2, and 3.2, respectively. Forward flexion (48° to 87°), abduction (52° to 79°), external rotation (18° to 22°), and internal rotation (buttock to L2) were improved. Conclusions: After primary RTSA in a Korean population, the complication, reintervention, and revision rates were 13.94%, 5.63%, and 4.02%, respectively. Careful evaluation of the complications and adequate treatments should be performed.


Assuntos
Artroplastia do Ombro , Fraturas Periprotéticas , Articulação do Ombro , Masculino , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Ombro/efeitos adversos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Resultado do Tratamento , Fraturas Periprotéticas/etiologia , Escápula , Estudos Retrospectivos , Amplitude de Movimento Articular , Reoperação/efeitos adversos
12.
JBJS Rev ; 12(4)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38574183

RESUMO

¼ Reverse total shoulder arthroplasty was designed to function in the rotator cuff deficient shoulder by adjusting the glenohumeral center of rotation (COR) to maximize deltoid function.¼ Adjustments in the COR ultimately lead to changes in resting tension of the deltoid and remaining rotator cuff, which can affect implant stability and risk of stress fracture.¼ Soft-tissue balance and complication profiles can be affected by humeral component (version, neck shaft angle, and inlay vs. onlay) and glenoid component (sagittal placement, version, inclination, and lateralization) design and application.¼ A good understanding of the effects on soft-tissue balance and complication profile is critical for surgeons to best provide optimal patient outcomes.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Prótese de Ombro , Humanos , Artroplastia do Ombro/efeitos adversos , Articulação do Ombro/cirurgia , Ombro/cirurgia , Prótese de Ombro/efeitos adversos , Manguito Rotador/cirurgia
13.
Bone Joint J ; 106-B(5): 482-491, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38688478

RESUMO

Aims: Metal and ceramic humeral head bearing surfaces are available choices in anatomical shoulder arthroplasties. Wear studies have shown superior performance of ceramic heads, however comparison of clinical outcomes according to bearing surface in total shoulder arthroplasty (TSA) and hemiarthroplasty (HA) is limited. This study aimed to compare the rates of revision and reoperation following metal and ceramic humeral head TSA and HA using data from the National Joint Registry (NJR), which collects data from England, Wales, Northern Ireland, Isle of Man and the States of Guernsey. Methods: NJR shoulder arthroplasty records were linked to Hospital Episode Statistics and the National Mortality Register. TSA and HA performed for osteoarthritis (OA) in patients with an intact rotator cuff were included. Metal and ceramic humeral head prostheses were matched within separate TSA and HA groups using propensity scores based on 12 and 11 characteristics, respectively. The primary outcome was time to first revision and the secondary outcome was non-revision reoperation. Results: A total of 4,799 TSAs (3,578 metal, 1,221 ceramic) and 1,363 HAs (1,020 metal, 343 ceramic) were included. The rate of revision was higher for metal compared with ceramic TSA, hazard ratio (HR) 3.31 (95% confidence interval (CI) 1.67 to 6.58). At eight years, prosthesis survival for ceramic TSA was 98.7% (95% CI 97.3 to 99.4) compared with 96.4% (95% CI 95.2 to 97.3) for metal TSA. The majority of revision TSAs were for cuff insufficiency or instability/dislocation. There was no significant difference in the revision rate for ceramic compared with metal head HA (HR 1.33 (95% CI 0.76 to 2.34)). For ceramic HA, eight-year prosthetic survival was 92.8% (95% CI 86.9 to 96.1), compared with 91.6% (95% CI 89.3 to 93.5) for metal HA. The majority of revision HAs were for cuff failure. Conclusion: The rate of all-cause revision was higher following metal compared with ceramic humeral head TSA in patients with OA and an intact rotator cuff. There was no difference in the revision rate for HA according to bearing surface.


Assuntos
Artroplastia do Ombro , Cerâmica , Hemiartroplastia , Desenho de Prótese , Falha de Prótese , Reoperação , Prótese de Ombro , Humanos , Reoperação/estatística & dados numéricos , Hemiartroplastia/métodos , Masculino , Feminino , Artroplastia do Ombro/métodos , Idoso , Pessoa de Meia-Idade , Osteoartrite/cirurgia , Sistema de Registros , Cabeça do Úmero/cirurgia , Idoso de 80 Anos ou mais , Metais
15.
BMJ ; 385: e077939, 2024 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-38688550

RESUMO

OBJECTIVES: To answer a national research priority by comparing the risk-benefit and costs associated with reverse total shoulder replacement (RTSR) and anatomical total shoulder replacement (TSR) in patients having elective primary shoulder replacement for osteoarthritis. DESIGN: Population based cohort study using data from the National Joint Registry and Hospital Episode Statistics for England. SETTING: Public hospitals and publicly funded procedures at private hospitals in England, 2012-20. PARTICIPANTS: Adults aged 60 years or older who underwent RTSR or TSR for osteoarthritis with intact rotator cuff tendons. Patients were identified from the National Joint Registry and linked to NHS Hospital Episode Statistics and civil registration mortality data. Propensity score matching and inverse probability of treatment weighting were used to balance the study groups. MAIN OUTCOME MEASURES: The main outcome measure was revision surgery. Secondary outcome measures included serious adverse events within 90 days, reoperations within 12 months, prolonged hospital stay (more than three nights), change in Oxford Shoulder Score (preoperative to six month postoperative), and lifetime costs to the healthcare service. RESULTS: The propensity score matched population comprised 7124 RTSR or TSR procedures (126 were revised), and the inverse probability of treatment weighted population comprised 12 968 procedures (294 were revised) with a maximum follow-up of 8.75 years. RTSR had a reduced hazard ratio of revision in the first three years (hazard ratio local minimum 0.33, 95% confidence interval 0.18 to 0.59) with no clinically important difference in revision-free restricted mean survival time, and a reduced relative risk of reoperations at 12 months (odds ratio 0.45, 95% confidence interval 0.25 to 0.83) with an absolute risk difference of -0.51% (95% confidence interval -0.89 to -0.13). Serious adverse events and prolonged hospital stay risks, change in Oxford Shoulder Score, and modelled mean lifetime costs were similar. Outcomes remained consistent after weighting. CONCLUSIONS: This study's findings provide reassurance that RTSR is an acceptable alternative to TSR for patients aged 60 years or older with osteoarthritis and intact rotator cuff tendons. Despite a significant difference in the risk profiles of revision surgery over time, no statistically significant and clinically important differences between RTSR and TSR were found in terms of long term revision surgery, serious adverse events, reoperations, prolonged hospital stay, or lifetime healthcare costs.


Assuntos
Artroplastia do Ombro , Osteoartrite , Sistema de Registros , Reoperação , Humanos , Inglaterra/epidemiologia , Osteoartrite/cirurgia , Masculino , Feminino , Artroplastia do Ombro/efeitos adversos , Idoso , Pessoa de Meia-Idade , Reoperação/estatística & dados numéricos , Pontuação de Propensão , Estudos de Coortes , Tempo de Internação/estatística & dados numéricos , Resultado do Tratamento , Análise Custo-Benefício , Idoso de 80 Anos ou mais , Articulação do Ombro/cirurgia
16.
Arch Orthop Trauma Surg ; 144(5): 1925-1935, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38523239

RESUMO

BACKGROUND: Patients who undergo reverse total shoulder arthroplasty (RTSA) are getting younger with greater function expectations. This retrospective, longitudinal study of prospectively collected data compared perceived shoulder function and strength, active shoulder mobility, radiographic evidence of scapular notching, and implant survival over the initial 2-years post-RTSA among patient groups who received either standard central fixation point liner and glenoid baseplate implants, or lower size profile mini-humeral tray with offset trunnion options and mini-augmented glenoid baseplate implants. MATERIALS AND METHODS: Patients who underwent primary RTSA using standard central fixation point liner and glenoid baseplate implants (Group 1, n = 180) were compared with patients who underwent primary RTSA using lower size profile mini-humeral tray with offset trunnion options and mini-augmented glenoid baseplate implants (Group 2, n = 53) for active shoulder mobility, American Shoulder and Elbow Surgeons (ASES) score, perceived ability to lift 10 lbs (4.5 kg) overhead, radiographic evidence of scapular notching, and implant survival. Data was collected pre-surgery, 6-weeks, 6-months, 1-year, and 2-years post-RTSA (p ≤ 0.05). RESULTS: More Group 2 patients had more complex B or C Walch glenoid morphology, while Group 1 had more A1 or A2 types (p ≤ 0.001). Group 2 had greater active shoulder flexion at 6-months, 1-year, and 2-years (p ≤ 0.018) and external rotation (in adduction) at 6-months and 2-years (p ≤ 0.004) compared to Group 1, with higher ASES scores at 6-months and 2-years (p ≤ 0.026) (with small-to-medium effect sizes), and with more patients meeting or exceeding the minimal clinically important difference (MCID) at 2-years (p = 0.045) and patient acceptable symptomatic state (PASS) levels at 6-months, 1-year and 2-years (p ≤ 0.045). Scapular notching was identified in six of 53 (11.3%) Group 2 patients and in 32 of 180 (17.7%) Group 1 patients. Group 1 patients had more grade 2 or greater scapular notching grades compared to Group 2 (p = 0.04). Implant survival was comparable with Group 1 = eight of 180 (4.4%) and Group 2 = 1 of 53 (1.9%) of patients requiring removal for 95.6% and 98.1% implant survival, respectively. CONCLUSION: Limited scapular notching and excellent implant survival was observed in both groups. Despite including individuals with more complex glenoid deficiency, patients receiving the lower size profile implants generally displayed better active shoulder mobility and perceived shoulder function compared to those who received standard implants. These patients also more frequently met or exceeded the MCID by 2-years post-RTSA and PASS levels by 6-months, 1-year, and 2-years post-RTSA, with lower scapular notching grades. LEVEL OF EVIDENCE: Retrospective comparative study.


Assuntos
Artroplastia do Ombro , Prótese de Ombro , Humanos , Artroplastia do Ombro/métodos , Artroplastia do Ombro/instrumentação , Estudos Retrospectivos , Masculino , Idoso , Feminino , Pessoa de Meia-Idade , Articulação do Ombro/cirurgia , Desenho de Prótese , Estudos Longitudinais , Úmero/cirurgia , Amplitude de Movimento Articular , Idoso de 80 Anos ou mais
17.
BMC Musculoskelet Disord ; 25(1): 231, 2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38521910

RESUMO

BACKGROUND: The current study aimed to determine the changes in pre-and post-operative Pittsburg sleep quality index (PSQI) and Tampa scale of kinesiophobia (TSK) values ​​according to the Hamada classification in patients who underwent reverse shoulder arthroplasty (RSA) for rotator cuff tear arthropathy (RCTA). METHODS: One hundred and eight patients who underwent RSA for RCTA were reviewed retrospectively. The patients were divided into two groups with low grade (stages 1-2-3) (n = 49) and high grade (stages 4a-4b-5) (n = 59) according to the Hamada classification, which is the radiographic evaluation of RCTA. PSQI and TSK values ​​were calculated preoperatively, and post-operatively at the 6th week, 6th month, and 1st year. The change in PSQI and TSK values ​​between the evaluations and the effect of staging according to the Hamada classification on this change was examined. RESULTS: When compared in preoperative evaluations, PSQI and TSK scores were found to be lower in low-grade group 1 (7.39 ± 1.56, 51.88 ± 4.62, respectively) than in high-grade group 2 (10.47 ± 2.39, 57.05 ± 3.25, respectively) according to Hamada classification (both p < 0.001). In the postoperative evaluations, PSQI and TSK results decreased gradually compared to the preoperative evaluations, and there was a severe decrease in both parameters between the 6th-week and 6th-month evaluations (both p < 0.001). Preoperatively, 102 (95%) patients had sleep disturbance (PSQI ≥ 6), and 108 (100%) patients had high kinesiophobia (TSK > 37). In the 1st year follow-ups, sleep disturbance was observed in 5 (5%) patients and kinesiophobia in 1 (1%) patient. When the Hamada stages were compared, it was seen that there was a significant difference before the operation (both p < 0.001), but the statistically significant difference disappeared in the PSQI value in the 1st year (p = 0.092) and in the TSK value in the 6th month (p = 0.164) post-operatively. It was observed that Hamada staging caused significant differences in PSQI and TSK values ​​in the preoperative period but did not affect the clinical results after treatment. CONCLUSIONS: RSA performed based on RCTA improves sleep quality and reduces kinesiophobia. RCTA stage negatively affects PSQI and TSK before the operation but does not show any effect after the treatment.


Assuntos
Artroplastia do Ombro , Artropatias , Lesões do Manguito Rotador , Artropatia de Ruptura do Manguito Rotador , Articulação do Ombro , Humanos , Artroplastia do Ombro/efeitos adversos , Artroplastia do Ombro/métodos , Manguito Rotador/cirurgia , Estudos Retrospectivos , Cinesiofobia , Resultado do Tratamento , Artropatia de Ruptura do Manguito Rotador/cirurgia , Artropatias/cirurgia , Sono , Lesões do Manguito Rotador/complicações , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Articulação do Ombro/cirurgia , Amplitude de Movimento Articular
18.
JBJS Rev ; 12(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38507516

RESUMO

BACKGROUND: Many patients who undergo shoulder arthroplasty (SA) have had at least 1 nonarthroplasty shoulder surgery before the surgery. There is conflicting evidence regarding the effects of previous shoulder surgery on the outcome of SA. A systematic review was conducted to compare functional outcomes and complications between SA patients with and without prior non-SA surgery on the ipsilateral shoulder. METHODS: We followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines and searched MEDLINE/PubMed, Embase, Scopus, and Web of Science comprehensively from inception to January 2023. Based on 9,279 records reviewed, 26 comparative studies were included in the meta-analysis consisting of 5,431 shoulders with prior nonarthroplasty procedures (cases) and 55,144 shoulders without previous surgery (controls). Variables such as functional scores, complications, and range of motion were compared between cases and controls using Review Manager Software. In addition, subgroup analysis was conducted based on prior surgery type (rotator cuff repair [RCR], open reduction and internal fixation [ORIF], soft tissue repairs, and not specified) and type of SA (hemiarthroplasty, anatomical total shoulder arthroplasty, and reverse total shoulder arthroplasty [RTSA]). The results were presented as odds ratios (ORs) or standardized mean differences (SMDs). RESULTS: Except for a higher rate of periprosthetic joint infection (PJI) in patients who had undergone previous arthroscopic surgery (OR, 2.58; 95% confidence interval [CI], 1.66-4.01; p < 0.01), a higher rate of complications was only observed in patients with previous ORIF. These complications included aseptic loosening (OR, 3.43; 95% CI, 2.14-5.50; p < 0.01), shoulder dislocation (OR, 2.25; 95% CI, 1.05-4.84; p = 0.04), overall complication (OR, 3.95; 95% CI, 2.38-6.55; p < 0.01), and revision (OR, 2.52; 95% CI, 1.28-4.97; p = 0.01). Patients with a history of previous surgery demonstrated inferior functional outcomes in comparison with the control group, including American Shoulder and Elbow Surgeons (SMD, -0.39; 95% CI, -0.51 to -0.27; p < 0.01; I2 = 36%), Constant-Murley score (SMD, -0.34; 95% CI, -0.44 to -0.24; p < 0.01; I2 = 0%), abduction (SMD, -0.26; 95% CI, -0.45 to -0.08; p = 0.01; I2 = 54%), and flexion (SMD, -0.33; 95% CI, -0.46 to -0.21; p < 0.01; I2 = 40%). Subgroup analysis by previous type of surgery was not possible regarding functional outcomes. CONCLUSION: Patients who have had prior fracture surgery are at a higher risk of complications, reoperations, and revisions after SA than controls. The normal shoulder anatomy may be disrupted by prior surgery, which makes arthroplasty technically challenging, particularly when it comes to soft tissue balance. On the other hand, RCR before SA did not negatively affect clinical outcomes after RTSA and did not have a higher rate of overall complications (except PJI). LEVEL OF EVIDENCE: Level III (Treatment Studies). See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia do Ombro , Hemiartroplastia , Luxação do Ombro , Humanos , Artroplastia do Ombro/efeitos adversos , Artroplastia do Ombro/métodos , Resultado do Tratamento
19.
Artigo em Inglês | MEDLINE | ID: mdl-38546429

RESUMO

Immobilization for acromial and scapular spine stress AU4fractures (AF/SSF) after reverse total shoulder arthroplasty (RSA) is associated with patient dissatisfaction. Our study reports the effects and safety of intranasal calcitonin alongside sling immobilization on pain and function in the treatment of AF/SSF after RSA. The treatment was regimented calcitonin (salmon) 200 unit/actuation nasal spray (1 spray/day) for 6 weeks with sling immobilization for 4 weeks. Each patient was monitored through blood work. Visual analog scale, American Shoulder and Elbow Surgeons score, and active range of motion were collected preoperatively, postoperatively, at presentation of AF/SSF, and after completion of calcitonin treatment. Two hundred eighty-two RSAs were performed by two board-certified orthopaedic surgeons, of which 18 patients sustained AF/SSF (6.4%). Ten patients met inclusion criteria (nine AFs and one SSF). After calcitonin treatment, patients demonstrated an average improvement of visual analog scale of 5.8 points, active range of motion of 46_, and American Shoulder and Elbow Surgeons score of 43.6 points at average 7.53 months after RSA. No medical complications were reported at 6-month follow-up after calcitonin treatment. The use of intranasal calcitonin was not associated withadverse events including no aberrations/signs of cancer at 6-month follow-up after administration. Calcitonin with sling immobilization markedly improved clinical and functional outcomes of patients with nondisplaced AF/SSF and may be considered by orthopaedic surgeons for symptom management.


Assuntos
Artroplastia do Ombro , Conservadores da Densidade Óssea , Fraturas de Estresse , Humanos , Calcitonina , Artroplastia do Ombro/efeitos adversos , Uso Off-Label , Escápula , Hormônios e Agentes Reguladores de Cálcio
20.
Int Orthop ; 48(5): 1285-1294, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38478022

RESUMO

PURPOSE: Prevalence of axillary (AN) and/or suprascapular (SSN) neuropathy in rotator cuff tear arthropathy (RCTA) is unknown. We aimed to prospectively evaluate for preoperative neurodiagnostic abnormalities in order to determine their prevalence, location, and influence on reverse shoulder arthroplasty (RSA) outcomes. METHODS: Patients who underwent RSA for RCTA were prospectively included. An electromyography and nerve conduction study were performed pre and post-surgery. Clinical situation: VAS, Relative Constant-Murley Score (rCMS) and ROM over a minimum of two years follow-up. RESULTS: Forty patients met the inclusion criteria; mean follow-up was 28.4 months (SD 4.4). Injuries in RCTA were present in 83.9% (77.4% in AN and 45.2% in SSN). There were no differences on preoperative VAS, ROM, and rCMS between patients with and without preoperative nerve injuries. Four acute postoperative neurological injuries were registered under chronic preoperative injuries. Six months after RSA, 69% of preoperative neuropathies had improved (82.14% chronic injuries and 77.7% disuse injuries). No differences in improvement between disuse and chronic injuries were found, but patients with preoperative neuropathy that had not improved at the postoperative electromyographic study at six months, scored worse on the VAS (1.44 vs 2.66; p .14) and rCMS (91.6 vs 89.04; p .27). CONCLUSIONS: The frequency of axillary and suprascapular neuropathies in RCTA is much higher than expected. Most of these injuries improve after surgery, with almost complete neurophysiological recovery and little functional impact on RSA. However, those patients with preoperative neuropathies and absence of neurophysiological improvement six months after surgery have lower functional results.


Assuntos
Artroplastia do Ombro , Lesões do Manguito Rotador , Artropatia de Ruptura do Manguito Rotador , Articulação do Ombro , Humanos , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/complicações , Lesões do Manguito Rotador/diagnóstico , Lesões do Manguito Rotador/cirurgia , Estudos Prospectivos , Ombro/cirurgia , Articulação do Ombro/cirurgia , Articulação do Ombro/inervação , Artroplastia do Ombro/efeitos adversos , Artroplastia do Ombro/métodos , Resultado do Tratamento , Estudos Retrospectivos , Amplitude de Movimento Articular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...