Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.905
Filtrar
1.
BMJ Case Rep ; 17(5)2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38719245

RESUMO

We report a case of a woman in her 30s who underwent femtosecond LASIK (laser-assisted in situ keratomileusis) in both eyes to correct her simple myopic astigmatism. After the surgery, both eyes developed diffuse lamellar keratitis, and intensive topical steroids were initiated to control the same. Subsequently, central toxic keratopathy (CTK) developed bilaterally. Three weeks after the surgery, the right eye showed signs of progressive epithelial ingrowth involving the pupillary area. Surgical intervention in the form of flap relift followed by debridement of the epithelial cells and an alcohol interface wash were performed to treat the same. This is the first report of an epithelial ingrowth following CTK after femtosecond LASIK.


Assuntos
Epitélio Corneano , Ceratomileuse Assistida por Excimer Laser In Situ , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Feminino , Adulto , Epitélio Corneano/patologia , Miopia/cirurgia , Complicações Pós-Operatórias/etiologia , Doenças da Córnea/etiologia , Desbridamento/métodos , Astigmatismo/etiologia , Astigmatismo/cirurgia , Retalhos Cirúrgicos/efeitos adversos
2.
Zhonghua Yan Ke Za Zhi ; 60(5): 440-446, 2024 May 11.
Artigo em Chinês | MEDLINE | ID: mdl-38706082

RESUMO

Objective: To explore the differences in clinical characteristics and interocular interactions between patients with anisometropic amblyopia and ametropic amblyopia. Methods: Cross-sectional study. The newly diagnosed anisometropic (the binocular difference in spherical equivalent≥1.00 D) amblyopia patients and ametropic amblyopia patients (aged 4 to 6 years) in Beijing Tongren Hospital from January 2020 to December 2022 were involved. Patients were further categorized by the refractive status after cycloplegia, including hyperopia, myopia, astigmatism, hyperopia with astigmatism, myopia with astigmatism, mild anisometropia and severe anisometropia. Quantitative measurements of best-corrected visual acuity (logMAR), stereoacuity (transformed to log units), perceptual eye position and interocular suppression were performed, and the differences between groups were analyzed. The rank sum test was used for statistical evaluation. Results: The average age of 45 ametropic amblyopia patients (21 males and 24 females) and 84 anisometropic amblyopia patients (48 males and 36 females) was 5.0 (4.0, 5.0) years and 5.0 (4.0, 6.0) years, respectively. The interocular differences in spherical equivalent [2.56 (1.50, 4.19) D vs. 0.25 (0.13, 0.56) D] and best-corrected visual acuity [0.40 (0.18, 0.70) logMAR vs. 0.07 (0.00, 0.12) logMAR] were larger in patients with anisometropic amblyopia than those with ametropic amblyopia. The anisometropic amblyopia patients had worse stereoacuity [2.60 (2.00, 2.90) log arcsec vs. 2.00 (2.00, 2.30) log arcsec] and deeper suppression [20.0% (13.3%, 40.0%) vs. 10.0% (0, 23.3%)], compared with the ametropic amblyopia patients. The differences were all statistically significant (P<0.05). The suppression and stereoacuity between patients with hyperopic anisometropic amblyopia [suppression, 30.0% (17.5%, 50.0%); stereoacuity, 2.90 (2.30, 2.90) log arcsec] and astigmatic anisometropic amblyopia [suppression, 10.0% (0, 20.0%); stereoacuity, 2.00 (2.00, 2.30) log arcsec] were significantly different (P<0.05). The differences of suppression and stereoacuity between patients with severe (binocular difference in spherical equivalent>2.50 D) [suppression, 30.0% (20.0%, 53.3%); stereoacuity, 2.90 (2.57, 2.90) log arcsec] and mild anisometropia [suppression, 20.0% (0, 30.0%); stereoacuity, 2.00 (2.00, 2.90) log arcsec] were also statistically significant (P<0.05). Conclusions: Patients with anisometropic amblyopia have deeper binocular suppression, worse stereoacuity and more severe binocular interaction abnormality than those with ametropic amblyopia. The severity of anisometropia affects the degree of the interaction abnormality.


Assuntos
Ambliopia , Miopia , Visão Binocular , Humanos , Ambliopia/fisiopatologia , Masculino , Feminino , Estudos Transversais , Pré-Escolar , Miopia/complicações , Acuidade Visual , Criança , Astigmatismo , Anisometropia/complicações , Hiperopia/fisiopatologia
3.
J Refract Surg ; 40(5): e328-e335, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38717080

RESUMO

PURPOSE: To evaluate moderate to high astigmatism corrections on the outcomes of SmartSight lenticule extraction for myopic astigmatism with a new femtosecond laser system. METHODS: Two hundred ninety-two eyes consecutively treated for myopic astigmatism with astigmatism magnitude greater than 1.00 diopter (D) were evaluated at the 6-month follow-up visit. The mean age of the patients was 29 ± 6 years with a mean spherical equivalent of -5.06 ± 2.20 diopters (D) and a mean magnitude of refractive astigmatism of 1.74 ± 0.61 D. RESULTS: At 6 months, astigmatism was 0.10 ± 0.20 D. Uncorrected and corrected distance visual acuities (UDVA and CDVA, respectively) were both 0.0 ± 0.1 logMAR. Differences between postoperative UDVA and preoperative CDVA and the change in CDVA were both +0.4 ± 0.7 lines better than preoperatively (P < .0003). CONCLUSIONS: Lenticule extraction treatment using Smart-Sight is safe and efficacious at 6 months. Findings suggest that moderate to high astigmatism improves after SmartSight lenticule extraction in the treatment of myopic astigmatism. [J Refract Surg. 2024;40(5):e328-e335.].


Assuntos
Astigmatismo , Substância Própria , Lasers de Excimer , Miopia , Refração Ocular , Acuidade Visual , Humanos , Astigmatismo/fisiopatologia , Astigmatismo/cirurgia , Acuidade Visual/fisiologia , Estudos Retrospectivos , Adulto , Refração Ocular/fisiologia , Masculino , Feminino , Miopia/cirurgia , Miopia/fisiopatologia , Adulto Jovem , Substância Própria/cirurgia , Lasers de Excimer/uso terapêutico , Topografia da Córnea , Seguimentos , Resultado do Tratamento , Cirurgia da Córnea a Laser/métodos
4.
J Refract Surg ; 40(5): e291-e303, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38717083

RESUMO

PURPOSE: To compare differences in corneal densitometry (CD) and higher order aberrations (HOAs) in eyes that underwent small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for the treatment of myopia and myopic astigmatism at postoperative months 3, 6, and 12, and to evaluate their changes in a separate cohort of eyes after SMILE enhancement. METHODS: In this prospective, randomized, paired-eye clinical trial, consecutive eligible participants were randomized to undergo SMILE or FS-LASIK in either eye. Main outcome measures were CD and HOAs preoperatively and at 3, 6, and 12 months postoperatively. A separate cohort of consecutive patients who had SMILE and underwent enhancement were also included for comparison. RESULTS: For CD, no significant differences were found between SMILE and FS-LASIK up to month 12. For HOA measured by wavefront aberrometry, both SMILE and FS-LASIK had an increase in total root mean square (RMS) HOAs, spherical aberration (SA), and vertical coma up to month 12. SMILE had an additional increase in vertical quatrefoil, and FS-LASIK had an increase in horizontal coma at month 12. FS-LASIK had higher SA than SMILE, whereas SMILE had higher vertical quatrefoil than FS-LASIK at month 12. Central and posterior zone CD had significantly decreased after SMILE enhancement compared to after primary SMILE up to 2 years after enhancement. RMS HOAs, lower order aberrations, and SA were all increased after SMILE enhancement compared to after primary SMILE. CONCLUSIONS: SMILE induced lower SA but higher vertical quatrefoil than FS-LASIK at 1 year. Both SMILE and FS-LASIK had similar increases in RMS HOAs and vertical coma up to 1 year. There were no differences in CD between both groups. SMILE enhancement additionally had decreased central and posterior CD but greater RMS HOAs and SA compared to primary SMILE. [J Refract Surg. 2024;40(5):e291-e303.].


Assuntos
Aberrometria , Astigmatismo , Córnea , Substância Própria , Aberrações de Frente de Onda da Córnea , Densitometria , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Miopia , Refração Ocular , Acuidade Visual , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Estudos Prospectivos , Miopia/cirurgia , Miopia/fisiopatologia , Adulto , Feminino , Masculino , Lasers de Excimer/uso terapêutico , Acuidade Visual/fisiologia , Substância Própria/cirurgia , Córnea/cirurgia , Córnea/fisiopatologia , Adulto Jovem , Refração Ocular/fisiologia , Astigmatismo/cirurgia , Astigmatismo/fisiopatologia , Cirurgia da Córnea a Laser/métodos , Topografia da Córnea
5.
BMC Ophthalmol ; 24(1): 211, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38741093

RESUMO

OBJECTIVE: To investigate the correlation between higher-order aberrations (HOA) after small incision lenticule extraction (SMILE) and the severity of myopia and astigmatism, along with the relevant factors. These findings will provide valuable insights for decreasing the occurrence of HOA after SMILE and enhancing visual quality. METHODS: A total of 75 patients (150 eyes) with myopia and astigmatism who underwent SMILE were categorized into four groups based on the severity of myopia and astigmatism: Myopia Group 1 (Group M1, spherical diopter ranged from -1.00 D to -4.00 D), Myopia Group 2 (Group M2, spherical diopter ranged from -4.10 D to -10.00 D), Astigmatism Group 1 (Group A1, cylindrical diopter ranged from 0 D to -1.00 D), and Astigmatism Group 2 (Group A2, cylindrical diopter ranged from -1.10 D to -3.00 D). A comprehensive assessment was performed to examine the association between HOA and various relevant factors, including a detailed analysis of the subgroups. RESULTS: Group M1 had significantly lower levels of total eye coma aberration (CA), corneal total HOA (tHOA), internal tHOA, and vertical CA ( Z 3 - 1 ) after SMILE than Group M2 (P < 0.05). Similarly, Group A1 had significantly lower levels of total eye tHOA, CA, trefoil aberration (TA), corneal tHOA, TA, and vertical TA ( Z 3 - 3 ) after SMILE than Group A2 (P < 0.05). Pearson correlation analysis indicated a statistically significant positive relationship between the severity of myopia/astigmatism and most HOA (P < 0.05). Subgroup evaluations demonstrated a notable increase in postoperative HOA associated with myopia and astigmatism in Groups M2 and A2 compared with the control group. Lenticule thickness, postoperative central corneal thickness (CCT), postoperative uncorrected distance visual acuity (UDVA), and postoperative corneal Km and Cyl were strongly correlated with most HOA. Age, eyes, and postoperative intraocular pressure (IOP) were only associated with specific HOA. CONCLUSION: HOA positively correlated with the severity of myopia and astigmatism after SMILE. However, this relationship was not linear. HOA after SMILE was influenced by various factors, and additional specialized investigations are required to establish its clinical importance.


Assuntos
Astigmatismo , Cirurgia da Córnea a Laser , Aberrações de Frente de Onda da Córnea , Miopia , Refração Ocular , Acuidade Visual , Humanos , Miopia/cirurgia , Miopia/fisiopatologia , Astigmatismo/fisiopatologia , Astigmatismo/etiologia , Masculino , Feminino , Adulto , Acuidade Visual/fisiologia , Cirurgia da Córnea a Laser/métodos , Cirurgia da Córnea a Laser/efeitos adversos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/etiologia , Adulto Jovem , Refração Ocular/fisiologia , Substância Própria/cirurgia , Estudos Retrospectivos , Lasers de Excimer/uso terapêutico , Complicações Pós-Operatórias , Topografia da Córnea , Adolescente
6.
BMC Ophthalmol ; 24(1): 179, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38641836

RESUMO

BACKGROUND: Plusoptix photoscreeners are capable of measuring refractive errors of children from 1 meter distance, without cyloplegia. We aimed to compare refractive data obtained from the newest version of Plusoptix (model 12) with cycloplegic autorefraction. METHODS: We examined 111 consecutive children aged 3-7 years first by Plusoptix A12C under manifest condition and subsequently for cycloplegic refraction by Topcon KR-1 tabletop autorefractometer. Sphere, spherical equivalent, cylinder and axis of astigmatism measured by the two methods were analyzed to determine correlation, agreement and differences. RESULTS: Binocular examination of 111 children aged 4.86±1.27 years revealed good agreement between refractive data obtained by Plusoptix and cycloautorefraction, according to Bland-Altman plots. Significant (p < 0.001) and strong correlation was found between all refractive measurements (Pearson's r value of 0.707 for sphere, 0.756 for pherical equivalent, and 0.863 for cylinder). Plusoptix mean sphere, spherical equivalent and cylinder were 1.22, 0.56, and -1.32 D, respectively. Corresponding values for cycloautorefraction were 1.63, 1.00, and -1.26 D. The difference between axis of cylinder measured by the two methods was < 10° in 144 eyes (64.9%). CONCLUSIONS: Considering the significant agreement and correlation between Plusoptix photoscreener and cycloplegic autorefraction, the need for cycloplegic drops in refractive examination of children may be obviated. The mean difference between cylinder measurements are considerably trivial (0.06 D), but sphere is approximately 0.4 D underestimated by Plusoptix compared to cycloautorefraction, on average.


Assuntos
Astigmatismo , Erros de Refração , Seleção Visual , Criança , Humanos , Midriáticos , Seleção Visual/métodos , Erros de Refração/diagnóstico , Refração Ocular
7.
Sci Rep ; 14(1): 8868, 2024 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-38632326

RESUMO

A retrospective cohort study was conducted to observe the correction effect of Toric intraocular lens (IOL) implantation in cataract eyes with specific types of irregular corneal astigmatism. Thirty-four eyes with either the "asymmetric bow-tie" pattern (Type I) or the "angled bow-tie" pattern (Type II) were included. Corneal topography was assessed using Pentacam HR, and changes in preoperative corneal astigmatism, visual acuity, manifest refraction, and objective visual quality were measured and compared. The average uncorrected distance visual acuity improved significantly from 0.86 ± 0.40 logMAR to 0.22 ± 0.15 logMAR (P < 0.001). Preoperative corneal astigmatism of 2.05 ± 0.90 D was corrected to a postoperative residual astigmatism of 0.78 ± 0.57 D (P < 0.001), with 32% of eyes within 0.50 D. The residual astigmatism prediction errors in Type I and Type II cases were (0.97 ± 0.68 D) and (0.66 ± 0.37 D), respectively (P = 0.100). The mean spherical equivalent prediction error in Type II cases (0.07 ± 0.36 D) was significantly smaller than that in Type I cases (- 0.29 ± 0.52 D) (P = 0.030). This study concludes that Toric IOL implantation effectively corrects specific types of irregular corneal astigmatism in cataract surgery. Eyes with the "angled bow-tie" pattern show higher accuracy in refractive predictions compared to eyes with the "asymmetric bow-tie" pattern.


Assuntos
Astigmatismo , Catarata , Doenças da Córnea , Lentes Intraoculares , Facoemulsificação , Humanos , Astigmatismo/cirurgia , Implante de Lente Intraocular , Estudos Retrospectivos , Refração Ocular , Doenças da Córnea/cirurgia
9.
Arq Bras Oftalmol ; 87(4): e2023, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38656029

RESUMO

PURPOSE: To assess the outcomes of deep anterior lamellar keratoplasty or penetrating keratoplasty at the scar and the edema stages. METHODS: Forty-five patients (45 eyes) with keratoconus scar stage (scar group, n=26; penetrating keratoplasty a subgroup, n=7; deep anterior lamellar keratoplasty b subgroup, n=19) and keratoconus edema stage (edema group, n=19; penetrating keratoplasty c subgroup, n=12; deep anterior lamellar keratoplasty d group, n=7) who received penetrating keratoplasty or deep anterior lamellar keratoplasty from 2000 to 2022 were retrospectively studied. At 1, 6, and 12 months after surgery, the best-corrected visual acuity, astigmatism, spherical equivalent, corneal endothelial cell density, and complications were analyzed. RESULTS: The best-corrected visual acuity and average corneal endothelial cell loss rate were not significantly different between the scar and edema groups (p>0.05). At 6 and 12 months after surgery, the astigmatism and spherical equivalent in the scar group were significantly lower than those in the edema group (p<0.05). The spherical equivalent of the deep anterior lamellar keratoplasty b subgroup was lower than that of the penetrating keratoplasty a subgroup in the scar group 6 months after surgery (p<0.05). In the edema group, there was no significant difference in spherical equivalent between subgroups (p>0.05). There were no significant differences in best-corrected visual acuity and astigmatism between subgroups within the two groups (p>0.05). In comparison to the scar group, the edema group experienced more complications. According to a survival analysis, there was no statistically significant difference between the scar group and the edema group regarding the progression of vision. CONCLUSIONS: In terms of the outcomes and prognosis for vision after keratoplasty with edema stage and scar stage, deep anterior lamellar keratoplasty may be as effective as penetrating keratoplasty.


Assuntos
Cicatriz , Edema da Córnea , Ceratocone , Ceratoplastia Penetrante , Acuidade Visual , Humanos , Ceratocone/cirurgia , Ceratocone/complicações , Ceratocone/fisiopatologia , Masculino , Feminino , Estudos Retrospectivos , Ceratoplastia Penetrante/métodos , Adulto , Cicatriz/etiologia , Resultado do Tratamento , Edema da Córnea/cirurgia , Edema da Córnea/etiologia , Adulto Jovem , Transplante de Córnea/métodos , Fatores de Tempo , Adolescente , Astigmatismo/cirurgia , Astigmatismo/fisiopatologia , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Contagem de Células , Endotélio Corneano/patologia , Endotélio Corneano/cirurgia
10.
PLoS One ; 19(4): e0300576, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38640111

RESUMO

PURPOSE: The purpose of this study was to investigate the effect of the corneal back surface by comparing the keratometric astigmatism (K, derived from the corneal front surface) of a modern optical biometer against astigmatism of Total Keratometry (TK, derived from both corneal surfaces) in a large population with cataractous eyes. The results were then used to define linear prediction models to map K to TK. METHODS: From a large dataset containing bilateral biometric measurements (IOLMaster 700) in 9736 patients prior to cataract surgery, the total corneal astigmatism was decomposed into vectors for K, corneal back surface (BS), and TK. A multivariate prediction model (MV), simplified model with separation of vector components (SM) and a constant model (CM) were defined to map K to TK vector components. RESULTS: The K centroid (X/Y) showed some astigmatism with-the-rule (0.1981/-0.0211 dioptre (dpt)) whereas the TK centroid was located around zero (-0.0071/-0.0381 dpt against-the-rule) and the BS centroid showed systematic astigmatism against-the-rule (-0.2367/-0.0145 dpt). The respective TK-K centroid was located at -0.2052/-0.0302 dpt. The MV model showed the same performance (i.e. mean absolute residuum) as the SM did (0.1098 and 0.1099 dpt respectively) while the CM performed only slightly worse (0.1121 dpt mean absolute residuum). CONCLUSION: In cases where tomographic data are unavailable statistical models could be used to consider the overall contribution of the back surface to the total corneal astigmatism. Since the performance of the CM is sufficiently close to that of MV and SM we recommend using the CM which can be directly considered e.g. as surgically induced astigmatism.


Assuntos
Astigmatismo , Extração de Catarata , Doenças da Córnea , Humanos , Astigmatismo/diagnóstico , Biometria/métodos , Córnea/diagnóstico por imagem
11.
J Pak Med Assoc ; 74(3): 450-455, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38591276

RESUMO

Objectives: To assess the visual improvement and mean residual astigmatism in patients who underwent cataract surgery with toric intraocular lens. METHODS: The retrospective, observational study was conducted at the Department of Ophthalmology, Aga Khan University Hospital, Karachi, and comprised data from January 1, 2018, to December 31, 2020, related to adult patients who had regular astigmatism of at least 0.75D and underwent cataract surgery with toric intraocular lens implantation using a digital marker. The patients were followed up on post-operative days 1, 7, 30, 90 and 180. Along with age, the degree of astigmatism was noted. The visual acuity was calculated pre- and post-operatively. The mean residual astigmatism was then noted for all patients post-operatively. Data was analysed using SPSS 22. RESULTS: The sample comprised 240 eyes of 177 patients; 99(55.9%) males and 78(44.1%) females. The mean age of the sample was 62.5±10.6 years. The mean unaided visual acuity improved post-operatively from 0.57±0.38 to 0.07±0.22 at 90 days. At the 30-day follow-up, mean residual astigmatism had reduced from 1.52±0.84 to 0.01±0.09 (p<0.001). The mean intraocular lens rotation from the intended axis was 0.73°±0.92° on day 30. CONCLUSIONS: Toric intraocular lens implantation using a digital marker could effectively reduce the post-operative cylinder, and improve the unaided visual acuity following cataract surgery.


Assuntos
Astigmatismo , Catarata , Lentes Intraoculares , Facoemulsificação , Masculino , Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Implante de Lente Intraocular , Astigmatismo/cirurgia , Estudos Retrospectivos , Catarata/complicações , Catarata/terapia , Refração Ocular
12.
BMC Ophthalmol ; 24(1): 174, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627647

RESUMO

PURPOSE: To evaluate the long-term clinical outcomes of femtosecond thin-flap LASIK (femto-LASIK) for correction of refractive error after penetrating keratoplasty in keratoconus-affected eyes. SETTING: a private ophthalmology clinic. DESIGN: Prospective interventional case series. METHODS: This prospective interventional case series enrolled 22 eyes of 22 patients who underwent femto-LASIK for the management of post-penetrating keratoplasty ametropia. The refractive error, uncorrected (UDVA), and corrected (CDVA) distance visual acuities and vector analysis were reported in short-term and long-term period after surgery. RESULTS: The mean age was 32.7 ± 7.5 years (range, 23 to 47 years) at the surgery time. The average time between PK and femto-LASIK was 42.5 ± 31.7 months. The average follow-up duration after femto-LASIK was 81.2 ± 18.6 months. The mean preoperative UDVA significantly improved from 0.47 ± 0.15 logMAR to 0.35 ± 0.14 logMAR at 12 months (P = 0.048) and 0.4 ± 0.17 at final follow-up exam (P = 0.007). CDVA was 0.22 ± 0.1 at baseline which improved to 0.18 ± 0.15 and 0.15 ± 0.1 logMAR at 12 and 81 months, respectively. (Ps = 0.027, 0.014). The mean cylinder before surgery was - 5.04 ± 1.4D which significantly decreased to -1.5 ± 0.8 D at 12 months postoperatively. (P < 0.001). There was a significant increase in refractive astigmatism from 12 months to 81 months postoperatively (-3.1 ± 2.0, P = 0.002). At the final visit, the efficacy index was 0.83, and the safety index was 1.16. CONCLUSIONS: Despite the short-term outcome indicated that femo-LASIK was effective for correction of post-keratoplasty ametropia during short-term period, a notable regression in its effect was observed in the long-term follow-up. Therefore, the predictability of this technique might decrease in the long-term.


Assuntos
Astigmatismo , Ceratomileuse Assistida por Excimer Laser In Situ , Erros de Refração , Humanos , Adulto , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Ceratoplastia Penetrante/efeitos adversos , Estudos Prospectivos , Astigmatismo/etiologia , Astigmatismo/cirurgia , Refração Ocular , Lasers , Resultado do Tratamento , Lasers de Excimer/uso terapêutico
13.
Sci Rep ; 14(1): 8305, 2024 04 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594402

RESUMO

To investigate the associations between corneal curvature (CC) and other anterior segment biometrics in young myopic adults. In this retrospective multi-center study, 7893 young myopic adults were included. CC and other anterior segment biometrics were measured by Scheimpflug imaging (Pentacam). CC was defined as SimK at central 3 mm area, and other anterior segment biometrics included white-to-white corneal diameter (WTW), central corneal thickness (CCT), corneal volume (CV) at 3 mm, 5 mm, and 7 mm area, anterior corneal astigmatism (ACA), posterior corneal astigmatism (PCA), anterior corneal eccentricity (ACE) and asphericity (ACAP), posterior corneal eccentricity (PCE) and asphericity (PCAP), anterior chamber depth (ACD), and anterior chamber volume (ACV). Univariate regression analyses were used to assess the associations between CC and other anterior segment biometrics, and multivariate regression analyses were further performed to adjusted for age, gender and spherical equivalent. CC was higher in patients of female gender and higher myopia (all P < 0.05). Eyes in higher CC quartiles had lower WTW, thinner CCT, lower CV at 3 mm and 5 mm, lower ACD, and lower ACV (all P < 0.001), but had larger ACA, larger PCA, less PCE and less PCAP (all P < 0.001), compared to eyes in lower CC quartiles. The trends of CV at 7 mm, ACE and ACAP were inconsistent in different CC quartiles. After adjusting for age, gender and spherical equivalent with multivariate linear regression, CC was positively correlated to CV at 7 mm (ßs = 0.069), ACA (ßs = 0.194), PCA (ßs = 0.187), ACE (ßs = 0.072), PCAP (ßs = 0.087), and ACD (ßs = 0.027) (all P < 0.05), but was negatively correlated to WTW (ßs = - 0.432), CCT (ßs = - 0.087), CV-3 mm (ßs = - 0.066), ACAP (ßs = - 0.043), PCE (ßs = - 0.062), and ACV (ßs = - 0.188) (all P < 0.05). CC was associated with most of the other anterior segment biometrics in young myopic adults. These associations are important for better understanding of the interactions between different anterior segment structures in young myopic patients, and are also useful for the exploration of the pathogenesis of myopia.


Assuntos
Astigmatismo , Doenças da Córnea , Miopia , Adulto , Feminino , Humanos , Câmara Anterior/diagnóstico por imagem , Câmara Anterior/patologia , Astigmatismo/patologia , Biometria , Córnea/patologia , Doenças da Córnea/patologia , Miopia/patologia , Estudos Retrospectivos
14.
BMC Ophthalmol ; 24(1): 158, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38600456

RESUMO

BACKGROUND: This study aimed to compare the visual outcomes of the first operated eyes with those of the second operated eyes following small-incision lenticule extraction (SMILE). METHODS: A total of 202 patients (404 eyes) underwent SMILE using the tear film mark centration method for myopia and myopic astigmatism correction. Baseline characteristics, objective optical quality, decentered displacement, induced corneal aberrations, and modulation transfer function (MTF) values were assessed. Linear regression analyzed the relationship between decentration and visual quality parameters, including corneal aberrations and MTF values. RESULTS: No significant difference was observed in objective visual quality, efficacy, and safety indexes between the two groups (all P > 0.05). The average decentered displacement for the first and second surgical eyes was 0.278 ± 0.17 mm and 0.315 ± 0.15 mm, respectively (P = 0.002). The horizontal coma in the first surgical eyes were notably lower than in the second (P = 0.000). MTF values at spatial frequencies of 5, 10, 15, and 20 cycles/degree (c/d) were higher in the first surgical eyes compared to the second (all P < 0.05). Linear regression indicated that high-order aberrations (HOAs), root mean square (RMS) coma, spherical aberration, horizontal coma, vertical coma, and eccentric displacement were all linearly correlated. Furthermore, MTF values exhibited a linear relationship with eccentric displacement across these spatial frequencies. CONCLUSIONS: There was no discernible difference in visual acuity, efficacy, or safety between the two operated eyes. Nonetheless, the first operated eyes exhibited reduced decentered displacement and demonstrated superior outcomes in terms of horizontal coma and MTF values compared to the second operated eyes following SMILE. The variations in visual quality parameters were linearly correlated with decentered displacement.


Assuntos
Astigmatismo , Aberrações de Frente de Onda da Córnea , Miopia , Humanos , Refração Ocular , Coma , Topografia da Córnea , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Astigmatismo/cirurgia , Substância Própria/cirurgia
15.
Appl Opt ; 63(10): 2694-2703, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38568554

RESUMO

Accurate assessment of corneal curvatures using frequency domain optical coherence tomography (OCT) with galvanometer scanners remains challenging due to the well-known scan field distortion. This paper presents an algorithm and software for correcting the distortion using only two simple measurements in which a readily available standard sphere is positioned in different depths in front of the OCT scanner. This offers a highly accessible and easily reproducible method for the field distortion correction (FDC). The correction was validated by measuring different spherical phantoms and conducting corneal curvature measurements of ex vivo porcine corneas using a commercial spectral-domain OCT system and a clinically approved swept-source OCT as a reference instrument. Thus, the error in radius measurements of spherical phantoms was reduced by >90% and astigmatism by >80% using FDC. In explanted porcine eyes, the error in astigmatism measurements with the Telesto was reduced by 75% for power and 70% for angle. The best fitting sphere radius was determined up to a deviation of 0.4% from the Anterion. This paper describes a correction algorithm for OCT immanent distortion that is applicable to any scanning OCT setup and enables precise corneal curvature measurements. The MATLAB software for the FDC is publicly available on GitHub.


Assuntos
Astigmatismo , Tomografia de Coerência Óptica , Animais , Suínos , Algoritmos , Software , Córnea/diagnóstico por imagem
16.
J Opt Soc Am A Opt Image Sci Vis ; 41(4): 730-738, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38568674

RESUMO

Here, we present a full wave propagation model that quantitatively assesses the effect of astigmatism on visual functions in eyes with diffractive bifocal IOLs. The proposed model with bifocal IOLs evaluated the image quality of each focus at varying degrees of corneal astigmatism with the metrics of modulation transfer function and light-in-the-bucket. The results show that corneal astigmatism alters the distance-near image quality balance. Positive (negative) astigmatism has more detrimental effects on far (near) vision. Additionally, bifocal IOLs are more vulnerable to corneal astigmatism, highlighting the need to consider multifocal toric IOLs with astigmatism greater than 1.0 D. The numerical results closely agreed with previous relevant clinical findings, suggesting the clinical usability of the presented method in predicting the postoperative visual function of patients.


Assuntos
Astigmatismo , Lentes Intraoculares , Lentes Intraoculares Multifocais , Humanos , Olho
17.
J Refract Surg ; 40(4): e208-e217, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38593256

RESUMO

PURPOSE: To evaluate spherical intraocular lens (IOL) implantation for cataracts in keratoconic eyes followed by optional refractive toric lens exchange to improve uncorrected visual acuity. METHODS: This retrospective study evaluated cataract surgery outcomes in keratoconic eyes. Eyes treated with a spherical IOL targeted for -2.00 diopters (D) either achieved acceptable manifest refraction and desired exchange with a toric IOL (Group 1); achieved satisfactory manifest refraction and chose to use spectacles or contact lenses (Group 2); or did not achieve acceptable refraction and used contact lenses (Group 3). Group 4 had single-stage toric IOL implantation with plano target. Corrected and uncorrected distance visual acuity (CDVA and UDVA) and keratometry were analyzed. RESULTS: Groups 1 to 4 had 18, 23, 18, and 26 eyes, respectively. A staged toric exchange resulted in significantly better (P = .02) UDVA (mean: 0.15 logMAR; 20/25 Snellen) than initial toric IOL implantation (0.24 logMAR; 20/30 Snellen). All toric IOL exchange eyes achieved 20/30 or better CDVA and 94% had 20/40 or better UDVA. Mean manifest cylinder significantly decreased from 3.39 D before lens exchange to 1.10 D postoperatively. CONCLUSIONS: Initial implantation of a spherical IOL in keratoconic eyes allows basing toric calculations on the manifest refraction, which may be more reliable than keratometry measurements in keratoconic eyes. UDVA after staged toric IOL exchange was significantly better than after initial toric IOL implantation. Importantly, by staging use of toric lenses, the authors avoided cases where patients required a rigid contact lens after a toric IOL was implanted. [J Refract Surg. 2024;40(4):e207-e217.].


Assuntos
Astigmatismo , Catarata , Ceratocone , Lentes Intraoculares , Facoemulsificação , Humanos , Ceratocone/complicações , Ceratocone/cirurgia , Estudos Retrospectivos , Facoemulsificação/métodos , Resultado do Tratamento , Astigmatismo/cirurgia , Refração Ocular , Catarata/complicações
18.
J Refract Surg ; 40(4): e239-e244, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38593260

RESUMO

PURPOSE: To explore changes in corneal epithelial thickness (CET) after femtosecond laser-assisted laser in situ keratomileusis in patients with high astigmatism. METHODS: CET was measured at every intersection of the concentric circles and specific axes using AngioVue optical coherence tomography (Angio-OCT) preoperatively and 1 month postoperatively. The average thickness of corneal central, paracentral, and peripheral regions was the mean of the points within the central 2, 2 to 5, and 5 to 7 mm areas, respectively. Correlation analysis was performed to investigate the association between CET along different axes and other preoperative and postoperative parameters. RESULTS: Forty-two eyes of 28 patients were included. CET along the astigmatic (K1) and perpendicular (K2) axes in the central and paracentral areas increased (P < .001), whereas that along the K2 axis decreased in the peripheral area 1 month postoperatively (P = .001). The amount of CET change in the peripheral area between the K1 and K2 axes was significantly different (P < .001). In the central area, the change in CET along the K2 axis was positively correlated with ablation depth (r = 0.315, P = .042) and negatively with refractive power after surgery (r = -0.347, P = .024). In the peripheral area, the changes in CET along both K1 and K2 axes were negatively correlated with ablation depth (r = -0.431, P = .004; r = -0.387, P = .011, respectively). CONCLUSIONS: Epithelial modeling differed between the different astigmatism axes after refractive surgery. The compensatory response of the corneal epithelium is more pronounced along the steeper axis. [J Refract Surg. 2024;40(4):e239-e244.].


Assuntos
Astigmatismo , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Acuidade Visual , Astigmatismo/cirurgia , Miopia/cirurgia , Estudos Prospectivos , Lasers , Lasers de Excimer/uso terapêutico
19.
J Refract Surg ; 40(4): e218-e228, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38593257

RESUMO

PURPOSE: To assess agreement between a new aberrometer (Osiris-T; CSO) employing pyramid wavefront sensor technique and Scheiner-Smirnov aberrometer (OPD-Scan III; Nidek) on measuring ocular, corneal, and internal aberrations in healthy participants. METHODS: The measurements were conducted three times consecutively by an experienced examiner. The total root mean square (RMS) aberrations, higher order aberration RMS, coma Z3±1, trefoil Z3±3, spherical aberration Z40, and astigmatism II Z4±2 up to 7th order were exported in both 4-and 6-mm pupil zones. The parameters between the two devices were statistically compared using the paired t-test, and the differences assessed with Bland-Altman plots and 95% limits of agreement. RESULTS: This prospective study included 70 right eyes of 70 healthy participants with an average age of 25.94 ± 6.59 years (range: 18 to 47 years). The mean difference in the two devices ranged from 0.01 µm for astigmatism II Z4±2 to 0.63 µm for total RMS in 4 mm and from 0.01 to 1.41 µm in 6-mm pupil size. The Bland-Altman analysis of ocular, corneal, and internal aberrations indicated high agreement between the two devices and the maximum absolute values for 95% limits of agreement ranged from 0.03 to 1.06 µm for 4-mm pupil diameters and 0.12 to 1.13 µm for 6-mm pupil diameters. CONCLUSIONS: The newly developed pyramid wavefront sensor technique aberrometer demonstrated a high agreement with a Scheiner-Smirnov aberrometer when measuring ocular, corneal, and internal aberrations in healthy participants. Thus, the two aberrometers may be considered interchangeable for clinical applications. [J Refract Surg. 2024;40(4):e218-e228.].


Assuntos
Astigmatismo , Humanos , Adulto Jovem , Adulto , Estudos Prospectivos , Córnea , Pupila , Biometria , Topografia da Córnea , Refração Ocular
20.
J Refract Surg ; 40(4): e245-e252, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38593261

RESUMO

PURPOSE: To evaluate clinical outcomes and visual quality 12 months after femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) performed with the Custom-Q algorithm for correction of myopia with or without astigmatism and compensate for age-related accommodation deficiency. METHODS: Patients who had Custom-Q FS-LASIK for myopia and myopic astigmatism with age-related accommodation deficiency were included in this retrospective study. Distance, intermediate, and near visual acuities, objective and subjective refractions, Q-factor, corneal higher order aberrations (HOAs), accommodation function, defocus curve, contrast sensitivity, and a subjective questionnaire assessing visual quality were evaluated 12 months postoperatively. RESULTS: Clinical data of 43 cases were analyzed. The mean age was 42.02 ± 1.85 years (range: 40 to 48 years). At the 12-month follow-up visit, there were 43 (100%), 42 (97%), and 33 (77%) patients who achieved a binocular uncorrected distance, intermediate, and near visual acuity, respectively, better than 20/20 separately. Defocus curves revealed better distance vision in the dominant eyes, and the nondominant eyes performed better at intermediate and near vergence (P < .001). The Q-value and corneal spherical aberration coefficient were more positive in the dominant eyes than those in the nondominant eyes (P < .001). The accommodative amplitude and relative accommodation improved binocularly (P < .001). The questionnaire demonstrated high patient satisfaction with near vision, and no one reported having severe visual disturbance. CONCLUSIONS: For myopic patients with age-related accommodation deficiency, the Custom-Q algorithm proved to be an effective way to achieve acceptable near vision without compromising distance vision. [J Refract Surg. 2024;40(4):e245-e252.].


Assuntos
Astigmatismo , Aberrações de Frente de Onda da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Humanos , Adulto , Estudos Retrospectivos , Acuidade Visual , Córnea , Miopia/cirurgia , Astigmatismo/cirurgia , Lasers de Excimer/uso terapêutico , Refração Ocular , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...