Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33.158
Filtrar
1.
J. optom. (Internet) ; 17(3): [100510], jul.-sept2024. tab
Artigo em Inglês | IBECS | ID: ibc-231872

RESUMO

Purpose: To evaluate the association between visual symptoms and use of digital devices considering the presence of visual dysfunctions. Methods: An optometric examination was conducted in a clinical sample of 346 patients to diagnose any type of visual anomaly. Visual symptoms were collected using the validated SQVD questionnaire. A threshold of 6 hours per day was used to quantify the effects of digital device usage and patients were divided into two groups: under and above of 35 years old. A multivariate logistic regression was employed to investigate the association between digital device use and symptoms, with visual dysfunctions considered as a confounding variable. Crude and the adjusted odds ratio (OR) were calculated for each variable. Results: 57.02 % of the subjects reported visual symptoms, and 65.02% exhibited some form of visual dysfunction. For patients under 35 years old, an association was found between having visual symptoms and digital device use (OR = 2.10, p = 0.01). However, after adjusting for visual dysfunctions, this association disappeared (OR = 1.44, p = 0.27) and the association was instead between symptoms and refractive dysfunction (OR = 6.52, p < 0.001), accommodative (OR = 10.47, p < 0.001), binocular (OR = 6.68, p < 0.001) and accommodative plus binocular dysfunctions (OR = 46.84, p < 0.001). Among patients over 35 years old, no association was found between symptoms and the use of digital devices (OR = 1.27, p = 0.49) but there was an association between symptoms and refractive dysfunction (OR = 3.54, p = 0.001). Conclusions: Visual symptoms are not dependent on the duration of digital device use but rather on the presence of any type of visual dysfunction: refractive, accommodative and/or binocular one, which should be diagnosed.(AU)


Assuntos
Humanos , Masculino , Feminino , Visão Ocular , Testes Visuais , Campos Visuais , Pessoas com Deficiência Visual , Visão Binocular , Inquéritos e Questionários , Optometria
2.
BMC Ophthalmol ; 24(1): 209, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38724962

RESUMO

BACKGROUD: The aim of this study was to investigate the associations between fluctuation in blood pressure (BP), ocular perfusion pressure (OPP) and visual field (VF) progression in normal-tension glaucoma (NTG). METHODS: This prospective, longitudinal study included 44 patients with NTG. Only newly diagnosed NTG patients who had not been treated with a glaucoma medication were included. Patients were examined every year for 7 years. Intraocular pressure (IOP), heart rate (HR), systolic BP (SBP), diastolic BP (DBP), ocular perfusion pressure (OPP), and diastolic ocular perfusion pressure (DOPP) were measured at the same time. Ophthalmic examinations, including perimetry, were performed also. Initial VF were compared with follow-up data after 7 years. RESULTS: After 7 years of follow-up, 9 of the 44 patients showed VF progression. The standard deviation (SD) of SBP and OPP were significantly associated with VF progression (P = 0.007, < 0.001, respectively). Multiple regression analysis showed that VF progression was significantly associated with SD of OPP (odds ratio, OR = 2.012, 95% CI = 1.016-3.985; P = 0.045). CONCLUSIONS: Fluctuation in OPP was associated with VF progression in patients with NTG.


Assuntos
Pressão Sanguínea , Progressão da Doença , Pressão Intraocular , Glaucoma de Baixa Tensão , Campos Visuais , Humanos , Glaucoma de Baixa Tensão/fisiopatologia , Campos Visuais/fisiologia , Masculino , Feminino , Pressão Intraocular/fisiologia , Estudos Prospectivos , Pessoa de Meia-Idade , Pressão Sanguínea/fisiologia , Seguimentos , Idoso , Testes de Campo Visual , Adulto
3.
Transl Vis Sci Technol ; 13(5): 9, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38743409

RESUMO

Purpose: To assess the diagnostic performance and structure-function association of retinal retardance (RR), a customized metric measured by a prototype polarization-sensitive optical coherence tomography (PS-OCT), across various stages of glaucoma. Methods: This cross-sectional pilot study analyzed 170 eyes from 49 healthy individuals and 68 patients with glaucoma. The patients underwent PS-OCT imaging and conventional spectral-domain optical coherence tomography (SD-OCT), as well as visual field (VF) tests. Parameters including RR and retinal nerve fiber layer thickness (RNFLT) were extracted from identical circumpapillary regions of the fundus. Glaucomatous eyes were categorized into early, moderate, or severe stages based on VF mean deviation (MD). The diagnostic performance of RR and RNFLT in discriminating glaucoma from controls was assessed using receiver operating characteristic (ROC) curves. Correlations among VF-MD, RR, and RNFLT were evaluated and compared within different groups of disease severity. Results: The diagnostic performance of both RR and RNFLT was comparable for glaucoma detection (RR AUC = 0.98, RNFLT AUC = 0.97; P = 0.553). RR showed better structure-function association with VF-MD than RNFLT (RR VF-MD = 0.68, RNFLT VF-MD = 0.58; z = 1.99; P = 0.047) in glaucoma cases, especially in severe glaucoma, where the correlation between VF-MD and RR (r = 0.73) was significantly stronger than with RNFLT (r = 0.43, z = 1.96, P = 0.050). In eyes with early and moderate glaucoma, the structure-function association was similar when using RNFLT and RR. Conclusions: RR and RNFLT have similar performance in glaucoma diagnosis. However, in patients with glaucoma especially severe glaucoma, RR showed a stronger correlation with VF test results. Further research is needed to validate RR as an indicator for severe glaucoma evaluation and to explore the benefits of using PS-OCT in clinical practice. Translational Relevance: We demonstrated that PS-OCT has the potential to evaluate the status of RNFL structural damage in eyes with severe glaucoma, which is currently challenging in clinics.


Assuntos
Glaucoma , Fibras Nervosas , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Campos Visuais , Humanos , Tomografia de Coerência Óptica/métodos , Estudos Transversais , Masculino , Feminino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Projetos Piloto , Campos Visuais/fisiologia , Glaucoma/fisiopatologia , Glaucoma/diagnóstico por imagem , Idoso , Células Ganglionares da Retina/patologia , Curva ROC , Testes de Campo Visual/métodos , Adulto , Pressão Intraocular/fisiologia
4.
Transl Vis Sci Technol ; 13(5): 10, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38743410

RESUMO

Purpose: To compare perimetric outcomes of an iPad perimetry app (Melbourne Rapid Fields [MRF]) with those of the Humphrey Field Analyser (HFA) testing children with glaucoma. Methods: Sixteen children diagnosed and treated for glaucoma were recruited to evaluate their perimetric performance over two visits. At each visit, they undertook visual field assessment using the MRF application as well as the HFA. The HFA test was part of their usual clinical work up and a clinical assistant judged which test format (24-2 SITA standard or SITA fast) might be suited to the testing of that child. The primary outcome measure was the association and repeatability of mean deviation (MD) for the MRF and HFA tests, by way of regression, intraclass correlation coefficient and Bland-Altman analysis. Secondary measures were comparisons of pattern deviation indices, test times as well as an indication of participant test preference. Summary data show means ± standard deviation. Results: The age for our cohort was 7 to 15 years of age (mean, 10.0 ± 2.4 years of age). The MRF MD was in close concordance to HFA MD with an intraclass correlation coefficient of 0.91 (95% confidence interval, 0.82-0.95). Bland-Altman analysis found little bias (-0.6 dB) and a 95% coefficient of repeatability of 2.1 dB in eyes having a normal HFA MD. In eyes with glaucomatous visual field defects the 95% coefficient of repeatability at retest was much larger for both the MRF (10.5 dB) as well as for the HFA (10.0 dB). Average MRF test times (5.6 ± 1.2 minutes) were similar to SITA Fast (5.4 ± 1.9 minutes) with both being significantly faster than SITA standard (8.6 ± 1.4 minutes; P < 0.001). All children chose testing with the MRF as their preference. Conclusions: MRF correlated strongly with HFA and was preferred by the children over the HFA. MRF is suitable for perimetric evaluation of children with glaucoma. Translational Relevance: This study finds that an iPad based visual field test can be used with children having glaucoma to yield outcomes similar to SITA-fast. Children indicate a preference for such testing.


Assuntos
Computadores de Mão , Glaucoma , Testes de Campo Visual , Campos Visuais , Humanos , Criança , Campos Visuais/fisiologia , Testes de Campo Visual/métodos , Testes de Campo Visual/instrumentação , Masculino , Feminino , Adolescente , Glaucoma/diagnóstico , Glaucoma/fisiopatologia , Reprodutibilidade dos Testes
5.
PLoS One ; 19(5): e0303400, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38739635

RESUMO

Visual abilities tend to vary predictably across the visual field-for simple low-level stimuli, visibility is better along the horizontal vs. vertical meridian and in the lower vs. upper visual field. In contrast, face perception abilities have been reported to show either distinct or entirely idiosyncratic patterns of variation in peripheral vision, suggesting a dissociation between the spatial properties of low- and higher-level vision. To assess this link more clearly, we extended methods used in low-level vision to develop an acuity test for face perception, measuring the smallest size at which facial gender can be reliably judged in peripheral vision. In 3 experiments, we show the characteristic inversion effect, with better acuity for upright faces than inverted, demonstrating the engagement of high-level face-selective processes in peripheral vision. We also observe a clear advantage for gender acuity on the horizontal vs. vertical meridian and a smaller-but-consistent lower- vs. upper-field advantage. These visual field variations match those of low-level vision, indicating that higher-level face processing abilities either inherit or actively maintain the characteristic patterns of spatial selectivity found in early vision. The commonality of these spatial variations throughout the visual hierarchy means that the location of faces in our visual field systematically influences our perception of them.


Assuntos
Reconhecimento Facial , Campos Visuais , Humanos , Campos Visuais/fisiologia , Feminino , Masculino , Adulto , Reconhecimento Facial/fisiologia , Adulto Jovem , Estimulação Luminosa , Percepção Visual/fisiologia , Acuidade Visual/fisiologia , Face/fisiologia
6.
Am J Ophthalmol ; 259: 7-14, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38708401

RESUMO

Purpose: To evaluate the diagnostic accuracy of retinal nerve fiber layer thickness (RNFLT) by spectral-domain optical coherence tomography (OCT) in primary open-angle glaucoma (POAG) in eyes of African (AD) and European descent (ED). Design: Comparative diagnostic accuracy analysis by race. Participants: 379 healthy eyes (125 AD and 254 ED) and 442 glaucomatous eyes (226 AD and 216 ED) from the Diagnostic Innovations in Glaucoma Study and the African Descent and Glaucoma Evaluation Study. Methods: Spectralis (Heidelberg Engineering GmbH) and Cirrus (Carl Zeiss Meditec) OCT scans were taken within one year from each other. Main Outcome Measures: Diagnostic accuracy of RNFLT measurements. Results: Diagnostic accuracy for Spectralis-RNFLT was significantly lower in eyes of AD compared to those of ED (area under the receiver operating curve [AUROC]: 0.85 and 0.91, respectively, P=0.04). Results for Cirrus-RNFLT were similar but did not reach statistical significance (AUROC: 0.86 and 0.90 in AD and ED, respectively, P =0.33). Adjustments for age, central corneal thickness, axial length, disc area, visual field mean deviation, and intraocular pressure yielded similar results. Conclusions: OCT-RNFLT has lower diagnostic accuracy in eyes of AD compared to those of ED. This finding was generally robust across two OCT instruments and remained after adjustment for many potential confounders. Further studies are needed to explore the potential sources of this difference.


Assuntos
Glaucoma de Ângulo Aberto , Pressão Intraocular , Fibras Nervosas , Disco Óptico , Curva ROC , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Campos Visuais , População Branca , Humanos , Glaucoma de Ângulo Aberto/etnologia , Glaucoma de Ângulo Aberto/diagnóstico , Tomografia de Coerência Óptica/métodos , Fibras Nervosas/patologia , Células Ganglionares da Retina/patologia , Feminino , Masculino , Pessoa de Meia-Idade , Pressão Intraocular/fisiologia , Campos Visuais/fisiologia , População Branca/etnologia , Reprodutibilidade dos Testes , Idoso , Disco Óptico/patologia , Disco Óptico/diagnóstico por imagem , Doenças do Nervo Óptico/diagnóstico , Doenças do Nervo Óptico/etnologia , Negro ou Afro-Americano/etnologia , Área Sob a Curva , Sensibilidade e Especificidade
7.
Sci Rep ; 14(1): 10261, 2024 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-38704441

RESUMO

Previous studies have suggested behavioral patterns, such as visual attention and eye movements, relate to individual personality traits. However, these studies mainly focused on free visual tasks, and the impact of visual field restriction remains inadequately understood. The primary objective of this study is to elucidate the patterns of conscious eye movements induced by visual field restriction and to examine how these patterns relate to individual personality traits. Building on previous research, we aim to gain new insights through two behavioral experiments, unraveling the intricate relationship between visual behaviors and individual personality traits. As a result, both Experiment 1 and Experiment 2 revealed differences in eye movements during free observation and visual field restriction. Particularly, simulation results based on the analyzed data showed clear distinctions in eye movements between free observation and visual field restriction conditions. This suggests that eye movements during free observation involve a mixture of conscious and unconscious eye movements. Furthermore, we observed significant correlations between conscious eye movements and personality traits, with more pronounced effects in the visual field restriction condition used in Experiment 2 compared to Experiment 1. These analytical findings provide a novel perspective on human cognitive processes through visual perception.


Assuntos
Movimentos Oculares , Personalidade , Campos Visuais , Humanos , Campos Visuais/fisiologia , Movimentos Oculares/fisiologia , Masculino , Personalidade/fisiologia , Feminino , Adulto , Adulto Jovem , Atenção/fisiologia , Percepção Visual/fisiologia
8.
Zhonghua Yan Ke Za Zhi ; 60(5): 423-429, 2024 May 11.
Artigo em Chinês | MEDLINE | ID: mdl-38706080

RESUMO

Objective: To investigate the effect of virtual reality visual training on remodeling optic nerve structures of glaucoma patients and analyze the influencing factors of visual training effect. Methods: A prospective non-randomized controlled trial was conducted. Glaucoma patients who presented to the Department of Ophthalmology, Beijing Shijitan Hospital between October 2021 and October 2022 were collected and divided into the training group or the control group according to their intentions. The training group accepted 3 months of visual training, while the control group did not. Optical coherence tomography was used to examine the disc edge area, cup volume, disc area, cup-to-disc ratio, and other parameters of the optic disc of both eyes of the patients at enrollment and after 3 months, and the changes of each parameter in the two groups were analyzed. Multivariate analysis was performed in the training group to investigate the effects of sex, age, visual field index, and mean defect on visual disc structure changes during visual training. Results: A total of 53 glaucoma patients (101 eyes) were included in the final analysis, among which the training group consisted of 27 cases (51 eyes), with 19 males and 8 females, and the age range was 48.0 (40.0, 61.0) years old. The control group comprised 26 cases (50 eyes), with 26 males and 11 females, and the age range was 54.0 (38.0, 63.0) years old. Compared with the control group, the deviation of cup volume was -0.006(-0.050, 0.015)mm3 (P<0.05), and the deviation of disc edge area was 0.00(-0.04, 0.05)mm2 (P<0. 05)in the visual training group after 3 months of visual training. The gender (OR=4.217, 95%CI=1.188-14.966) may be the influence factor of rim area. While,the mean defect (OR=1.526, 95%CI=0.245-9.491) was not that influential on rim area change. Conclusions: Visual training can increase the disc area and decrease the optic cup volume of the optic nerve in glaucoma patients. The rim area may be increased more easily after visual training in male glaucoma patients.


Assuntos
Glaucoma , Disco Óptico , Tomografia de Coerência Óptica , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto , Campos Visuais
9.
Harefuah ; 163(5): 298-304, 2024 May.
Artigo em Hebraico | MEDLINE | ID: mdl-38734943

RESUMO

INTRODUCTION: Glaucoma is a progressive optic neuropathy and is the leading cause of preventable irreversible blindness worldwide. Glaucoma causes progressive visual field loss and can have significant implications on the patient's quality of life. Lowering intraocular pressure (IOP) is the only treatment proven to prevent vision loss from glaucoma. It is achieved using medication, laser treatment and surgery. The treatment paradigm of glaucoma has been one whereby surgical intervention has been left for advanced cases due to a variety of reasons, mainly concerning safety and long term success. The past two decades have seen a paradigm shift towards earlier IOP lowering interventions using a wide array of different technologies in the laser and surgical spaces. This review aims to understand the background to this paradigm shift, its necessity, and its potential impact on the vision and life of glaucoma patients.


Assuntos
Glaucoma , Pressão Intraocular , Terapia a Laser , Qualidade de Vida , Humanos , Glaucoma/terapia , Glaucoma/cirurgia , Pressão Intraocular/fisiologia , Terapia a Laser/métodos , Cegueira/etiologia , Cegueira/prevenção & controle , Campos Visuais/fisiologia , Progressão da Doença , Doenças do Nervo Óptico/etiologia , Doenças do Nervo Óptico/terapia
10.
Vestn Oftalmol ; 140(2. Vyp. 2): 34-42, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38739129

RESUMO

PURPOSE: This study analyzes changes in light sensitivity in each test point of the visual field in patients with different stages of glaucoma. MATERIAL AND METHODS: The data of a prospective analytical case-control study were analyzed. All patients underwent assessment of retinal light sensitivity and its variability in 54 points corresponding to the 24-2 program. Mean light sensitivity values were calculated in each point. Intergroup analysis was performed to evaluate changes in light sensitivity in each point. RESULTS: The range of light sensitivity decrease in the early glaucoma group compared to the control group was from 1.5 to 3.6 dB. The range of light sensitivity decrease in the moderate glaucoma group compared to the control group was from 2.1 to 11.5 dB, and compared to the early glaucoma group - from -0.9 to 7.9 dB. The most frequent decrease in light sensitivity was detected in the nasal sector and along the horizontal line in the upper half of the visual field. This trend persisted within the central 10 degrees of the visual field. The range of light sensitivity decrease in the advanced glaucoma group compared to the control group was from 14.1 to 28.0 dB, and compared to the early glaucoma group - from 11.35 to 26.08 dB, compared to the moderate glaucoma group - from 9.1 to 23.5 dB. The most frequent and severe decrease in light sensitivity was detected in the paracentral zone in the lower half of the visual field. CONCLUSION: The study analyzed the trends in the development of glaucoma from the early to the advanced stage. The most frequent and severe defect in light sensitivity in cases of verified advanced glaucoma was found in the lower half of the visual field. Points No. 32, 33 and 40 can be indicated as the area of interest in assessing the progression of glaucoma, as they were found to have the most profound changes in light sensitivity as glaucoma progressed.


Assuntos
Progressão da Doença , Glaucoma , Testes de Campo Visual , Campos Visuais , Humanos , Campos Visuais/fisiologia , Glaucoma/fisiopatologia , Glaucoma/diagnóstico , Masculino , Feminino , Pessoa de Meia-Idade , Testes de Campo Visual/métodos , Estudos Prospectivos , Idoso , Estudos de Casos e Controles , Luz
11.
Vestn Oftalmol ; 140(2. Vyp. 2): 116-122, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38739140

RESUMO

PURPOSE: This study assesses the light sensitivity and its variability in each point of the visual field in patients without glaucoma and with different stages of glaucoma. MATERIAL AND METHODS: The data of a prospective analytical case-control study involving 500 patients were analyzed. The initial examination of all patients was performed using basic ophthalmological methods, including static perimetry. Retinal light sensitivity and its variability were assessed in 54 points corresponding to the Humphrey 24-2 program. Mean deviation and pattern standard deviation of light sensitivity were calculated for each point. RESULTS: The lowest light sensitivity values in patients with moderate glaucoma were found in the periphery of the nasal sector, at point No. 27 - 14.4 dB, and at points No. 24-26 along the horizontal axis from the nasal side - from 17.7 to 22.7 dB. The maximum variability of light sensitivity was found in the nasal sector on both sides of the horizontal line - from 10.7 to 11.5 dB. The average light sensitivity above the horizontal axis in patients with advanced glaucoma was 10.8 dB, which is 2 dB higher than in the lower half of the visual field - 8.8 dB. The highest light sensitivity values were found at points No. 24 - 17.7 dB and No. 31 - 16.78 dB, the lowest - at point No. 32 - 4.5 dB. The average variability values of light sensitivity in the upper half of the visual field were 9.6 dB, which is 1 dB less than in the lower half of the visual field - 10.6 dB. CONCLUSION: According to our data, points No. 32 and No. 40 are of particular interest in the diagnostic plan. In these loci, the highest light sensitivity values were determined in early and moderate glaucoma. However, the values in these points decrease significantly in advanced glaucoma. It can be assumed that changes in light sensitivity in these loci at the early stages of glaucoma may be a predictor of glaucoma progression.


Assuntos
Glaucoma , Retina , Testes de Campo Visual , Campos Visuais , Humanos , Campos Visuais/fisiologia , Testes de Campo Visual/métodos , Glaucoma/fisiopatologia , Glaucoma/diagnóstico , Pessoa de Meia-Idade , Masculino , Feminino , Retina/fisiopatologia , Estudos Prospectivos , Adulto , Luz , Idoso , Limiar Sensorial/fisiologia , Estudos de Casos e Controles , Reprodutibilidade dos Testes
12.
Jpn J Ophthalmol ; 68(3): 183-191, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38598144

RESUMO

PURPOSE: To assess the impact of glaucoma on perceiving three-dimensional (3D) shapes based on monocular depth cues. STUDY DESIGN: Clinical observational study. METHODS: Twenty glaucoma patients, subjected to binocular visual-field sensitivity (binocular-VFS) tests using a Humphrey Visual Field Analyzer, and 20 age-matched healthy volunteers, underwent two tasks: identifying the nearest vertex of a 3D shape using monocular shading (3D-SfS), texture (3D-SfT), or motion (3D-SfM) cues, and distinguishing elementary one-dimensional (1D) features of these cues. The association of the visual-field index (VFI) of binocular-VFS with 3D shape perception in glaucoma patients was also examined. RESULTS: Glaucoma patients demonstrated reduced accuracy in distinguishing 1D luminance brightness and a larger "error-in-depth" between the perceived and actual depths for 3D-SfM and 3D-SfS compared to healthy volunteers. Six glaucoma patients with a 100% VFI for binocular-VFS exhibited a similar error-in-depth to the other fourteen glaucoma patients; they had a larger error-in-depth for 3D-SfM compared to healthy volunteers. No correlation between the error-in-depth values and the VFI values of binocular-VFS was observed. CONCLUSIONS: The 3D shape perception in glaucoma patients varies based on the depth cue's characteristics. Impaired 1D discrimination and larger thresholds for 3D-SfM in glaucoma patients with a 100% VFI for binocular-VFS indicate more pronounced perceptual deficits of lower-level elementary features for 3D-SfS and higher-level visual processing of 3D shapes for 3D-SfM. The effects of the location and degree of binocular visual-field defects on 3D shape perception remain to be elucidated. Our research provides insights into the 3D shape extraction mechanism in glaucoma.


Assuntos
Sinais (Psicologia) , Percepção de Profundidade , Glaucoma , Visão Binocular , Visão Monocular , Campos Visuais , Humanos , Masculino , Feminino , Percepção de Profundidade/fisiologia , Visão Binocular/fisiologia , Campos Visuais/fisiologia , Pessoa de Meia-Idade , Idoso , Glaucoma/fisiopatologia , Glaucoma/diagnóstico , Visão Monocular/fisiologia , Testes de Campo Visual , Pressão Intraocular/fisiologia , Percepção de Forma/fisiologia , Adulto
13.
Jpn J Ophthalmol ; 68(3): 206-210, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38587788

RESUMO

PURPOSE: To retrospectively evaluate the 3-year efficacy and safety of single-agent omidenepag isopropyl in patients with normal tension glaucoma (NTG). STUDY DESIGN: Retrospective. METHODS: One hundred patients (100 eyes) who had newly been administered omidenepag isopropyl were enrolled in this study. Intraocular pressure (IOP) was compared at baseline and 6, 9, 12, 18, 24, 30, and 36 months after administration. The mean deviation values at baseline and 12, 24, and 36 months measured using the Humphrey visual field test (30-2 Swedish Interactive Threshold Algorithm standard) were compared. Adverse reactions and dropouts were assessed. RESULTS: IOP significantly decreased from 15.5±2.7 mmHg at baseline to 13.8 ±2.3 mmHg after 6 months, 13.9± 2.3 mmHg after 12 months, 13.9±2.3 mmHg after 18 months, 13.8±2.1 mmHg after 24 months, 13.9±2.0 mmHg after 30 months, and 13.6±1.7 mmHg after 36 months (P < 0.0001). There was no significant difference in the mean deviation values at baseline (-3.66±3.49 dB), 12 months (-3.41±3.80 dB), 24 months (-3.13±3.81 dB), and 36 months (-3.06±3.30 dB). Adverse reactions occurred in 11 patients (11.0%), including conjunctival hyperemia in 6 patients. Fifty-two patients (52.0%) were excluded from the analysis because they discontinued treatment either due to IOP measurement by NCT or the use of additional drugs. CONCLUSION: After the administration of omidenepag isopropyl, IOP in patients with NTG decreased within 3 years, visual fields were maintained, and safety was satisfactory. Thus, omidenepag isopropyl can be used as the first-line treatment for patients with NTG.


Assuntos
Pressão Intraocular , Glaucoma de Baixa Tensão , Soluções Oftálmicas , Campos Visuais , Humanos , Pressão Intraocular/efeitos dos fármacos , Pressão Intraocular/fisiologia , Masculino , Feminino , Estudos Retrospectivos , Glaucoma de Baixa Tensão/tratamento farmacológico , Glaucoma de Baixa Tensão/fisiopatologia , Glaucoma de Baixa Tensão/diagnóstico , Pessoa de Meia-Idade , Resultado do Tratamento , Idoso , Seguimentos , Campos Visuais/fisiologia , Tonometria Ocular , Adulto , Fatores de Tempo , Testes de Campo Visual
14.
Transl Vis Sci Technol ; 13(4): 23, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38630470

RESUMO

Purpose: The common protocol of full-field stimulus threshold (FST) testing recommends pupil dilation. The aim of this study is to investigate the difference between FST measurements with dilated and nondilated pupils in healthy subjects and patients with retinitis pigmentosa (RP). Methods: Twenty healthy subjects and 20 RP patients were selected. One pupil of each subject was dilated; the other eye was measured in physiological width of the pupil. The FST was conducted using Diagnosys Espion E2/E3 with white, blue, and red stimuli. Statistical analysis was conducted with a mixed-model analysis of variance and a paired t-test. Results: The statistical analysis revealed a significant difference between measurements of dilated and nondilated pupils with the following: blue stimuli for all subjects and groups except those with highly progressed RP; white stimuli for all tested subjects in total, for RP patients with better-preserved visual field (VF), and rod-mediated FST response; and red stimuli for RP patients with better-preserved VF and rod-mediated FST response. On average, the difference between the FST values for RP patients were -3.2 ± 3 dB for blue, -2.3 ± 2.9 dB for white, and -0.83 ± 3 dB for red stimuli. The correlation between the FST values of dilated and nondilated pupils with all three stimuli was linear. Conclusions: Current recommendations are to perform FST with dilated pupils. However, based on this study's findings, pupil dilation can be omitted for clinical diagnostics or rough follow-ups. Translational Relevance: Our data provide useful information for the clinical use of FST.


Assuntos
Pupila , Retinose Pigmentar , Humanos , Voluntários Saudáveis , Projetos de Pesquisa , Retinose Pigmentar/diagnóstico , Campos Visuais
15.
Sci Rep ; 14(1): 8980, 2024 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637554

RESUMO

Primate visual cortex exhibits key organizational principles: cortical magnification, eccentricity-dependent receptive field size and spatial frequency tuning as well as radial bias. We provide compelling evidence that these principles arise from the interplay of the non-uniform distribution of retinal ganglion cells, and a quasi-uniform convergence rate from the retina to the cortex. We show that convolutional neural networks outfitted with a retinal sampling layer, which resamples images according to retinal ganglion cell density, develop these organizational principles. Surprisingly, our results indicate that radial bias is spatial-frequency dependent and only manifests for high spatial frequencies. For low spatial frequencies, the bias shifts towards orthogonal orientations. These findings introduce a novel hypothesis about the origin of radial bias. Quasi-uniform convergence limits the range of spatial frequencies (in retinal space) that can be resolved, while retinal sampling determines the spatial frequency content throughout the retina.


Assuntos
Córtex Visual , Campos Visuais , Animais , Retina , Células Ganglionares da Retina , Redes Neurais de Computação
16.
Sensors (Basel) ; 24(8)2024 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-38676129

RESUMO

This study presents phosphenotron, a device for enhancing the sensory spatial resolution of phosphenes in the visual field (VF). The phosphenotron employs a non-invasive transcranial alternating current stimulation (NITACS) to modulate brain activity by applying weak electrical currents to the scalp or face. NITACS's unique application induces phosphenes, a phenomenon where light is perceived without external stimuli. Unlike previous invasive methods, NITACS offers a non-invasive approach to create these effects. The study focused on assessing the spatial resolution of NITACS-induced phosphenes, crucial for advancements in visual aid technology and neuroscience. Eight participants were subjected to NITACS using a novel electrode arrangement around the eye orbits. Results showed that NITACS could generate spatially defined phosphene patterns in the VF, varying among individuals but consistently appearing within their VF and remaining stable through multiple stimulations. The study established optimal parameters for vibrant phosphene induction without discomfort and identified electrode positions that altered phosphene locations within different VF regions. Receiver Operating characteristics analysis indicated a specificity of 70.7%, sensitivity of 73.9%, and a control trial accuracy of 98.4%. These findings suggest that NITACS is a promising, reliable method for non-invasive visual perception modulation through phosphene generation.


Assuntos
Fosfenos , Estimulação Transcraniana por Corrente Contínua , Campos Visuais , Humanos , Fosfenos/fisiologia , Estimulação Transcraniana por Corrente Contínua/métodos , Estimulação Transcraniana por Corrente Contínua/instrumentação , Masculino , Campos Visuais/fisiologia , Feminino , Adulto , Percepção Visual/fisiologia , Adulto Jovem , Eletrodos
17.
Sci Rep ; 14(1): 8907, 2024 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-38632334

RESUMO

In natural environments, head movements are required to search for objects outside the field of view (FoV). Here we investigate the power of a salient target in an extended visual search array to facilitate faster detection once this item comes into the FoV by a head movement. We conducted two virtual reality experiments using spatially clustered sets of stimuli to observe target detection and head and eye movements during visual search. Participants completed search tasks with three conditions: (1) target in the initial FoV, (2) head movement needed to bring the target into the FoV, (3) same as condition 2 but the periphery was initially hidden and appeared after the head movement had brought the location of the target set into the FoV. We measured search time until participants found a more salient (O) or less salient (T) target among distractors (L). On average O's were found faster than T's. Gaze analysis showed that saliency facilitation occurred due to the target guiding the search only if it was within the initial FoV. When targets required a head movement to enter the FoV, participants followed the same search strategy as in trials without a visible target in the periphery. Moreover, faster search times for salient targets were only caused by the time required to find the target once the target set was reached. This suggests that the effect of stimulus saliency differs between visual search on fixed displays and when we are actively searching through an extended visual field.


Assuntos
Movimentos Oculares , Movimentos da Cabeça , Humanos , Campos Visuais
18.
PLoS One ; 19(4): e0301999, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38635686

RESUMO

To study how the nervous system processes visual information, experimenters must record neural activity while delivering visual stimuli in a controlled fashion. In animals with a nearly panoramic field of view, such as flies, precise stimulation of the entire visual field is challenging. We describe a projector-based device for stimulation of the insect visual system under a microscope. The device is based on a bowl-shaped screen that provides a wide and nearly distortion-free field of view. It is compact, cheap, easy to assemble, and easy to operate using the included open-source software for stimulus generation. We validate the virtual reality system technically and demonstrate its capabilities in a series of experiments at two levels: the cellular, by measuring the membrane potential responses of visual interneurons; and the organismal, by recording optomotor and fixation behavior of Drosophila melanogaster in tethered flight. Our experiments reveal the importance of stimulating the visual system of an insect with a wide field of view, and we provide a simple solution to do so.


Assuntos
Drosophila melanogaster , Campos Visuais , Animais , Drosophila melanogaster/fisiologia , Estimulação Luminosa , Software , Interneurônios , Voo Animal/fisiologia , Percepção Visual/fisiologia
19.
Proc Natl Acad Sci U S A ; 121(16): e2309975121, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38588433

RESUMO

Research on attentional selection of stimulus features has yielded seemingly contradictory results. On the one hand, many experiments in humans and animals have observed a "global" facilitation of attended features across the entire visual field, even when spatial attention is focused on a single location. On the other hand, several event-related potential studies in humans reported that attended features are enhanced at the attended location only. The present experiment demonstrates that these conflicting results can be explained by differences in the timing of attentional allocation inside and outside the spatial focus of attention. Participants attended to fields of either red or blue randomly moving dots on either the left or right side of fixation with the task of detecting brief coherent motion targets. Recordings of steady-state visual evoked potentials elicited by the flickering stimuli allowed concurrent measurement of the time course of feature-selective attention in visual cortex on both the attended and the unattended sides. The onset of feature-selective attentional modulation on the attended side occurred around 150 ms earlier than on the unattended side. This finding that feature-selective attention is not spatially global from the outset but extends to unattended locations after a temporal delay resolves previous contradictions between studies finding global versus hierarchical selection of features and provides insight into the fundamental relationship between feature-based and location-based (spatial) attention mechanisms.


Assuntos
Eletroencefalografia , Potenciais Evocados Visuais , Humanos , Potenciais Evocados , Campos Visuais , Atenção , Estimulação Luminosa/métodos
20.
BMJ Open Ophthalmol ; 9(1)2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38626931

RESUMO

OBJECTIVE: To investigate the characteristics of beta parapapillary atrophy (ß-PPA) in patients with primary angle-closure suspect (PACS). METHODS AND ANALYSIS: In total, 215 and 259 eyes with PACS and non-PACS (NPACS), respectively, were enrolled in this observational, cross-sectional study. Stereoscopic fundus and optical coherence tomography images were used to characterise ß-PPA; the former was also used to measure the major ß-PPA parameters. Univariate and multiple logistic regression analyses were used to identify the factors correlated with the presence of ß-PPA and with ß-PPA parameters. RESULTS: The ß-PPA occurrence rates were 48.80% and 44.40% in the PACS and NPACS groups, respectively, with no significant difference between groups. Compared with that in the NPACS group, the ß-PPA area was significantly larger (p=0.005) in the PACS group, but the angular extent and maximum radial length did not differ between groups (p=0.110 and 0.657, respectively) after adjusting for age and axial length. The presence of ß-PPA was associated with older age (OR 1.057, 95% CI 1.028 to 1.088, p<0.001) and larger disc area (OR 1.716, 95% CI 1.170 to 2.517, p=0.006). A larger ß-PPA area was associated with older age (p=0.014), greater vertical cup-to-disc ratio (p=0.028), larger disc area (p<0.001) and PACS diagnosis (p=0.035). CONCLUSION: 48.80% of participants with PACS had ß-PPA, which is slightly larger than NPACS. The area of ß-PPA was larger in PACS, while the angular extent and maximum radial length did not differ between groups.


Assuntos
Oftalmopatias Hereditárias , Glaucoma de Ângulo Aberto , Atrofia Óptica , Disco Óptico , Humanos , Disco Óptico/patologia , Glaucoma de Ângulo Aberto/complicações , Atrofia Óptica/complicações , Estudos Transversais , Pressão Intraocular , Campos Visuais , Atrofia/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...