Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.108
Filtrar
1.
J Appl Biomater Funct Mater ; 22: 22808000241248886, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38678374

RESUMO

OBJECTIVE: To evaluate the effect of COVID-19 preventive mouthwashes on the surface hardness, surface roughness (Ra), and color change (ΔE) of three different polymer-based composite CAD/CAM materials (Vita Enamic (ENA), Grandio Block (GB), Lava Ultimate (LU)). METHODS: A total of 100 rectangular-shaped specimens with dimensions of 2 mm × 7 mm × 12 mm were obtained by sectioning three different CAD/CAM blocks and randomly divided into five subgroups according to the 30 days of mouthwash immersion protocol as follows: Control: artificial saliva, PVP-I: 1% povidone-iodine, HP: 1.5% hydrogen peroxide, CPC: mouthwash containing 0.075% cetylpyridinium chloride, EO: mouthwash containing essential oils. Microhardness, Ra, and ΔE values were measured at baseline and after 30 days of immersion protocols. Data were analyzed using the Wald Chi-square, two-way ANOVA, and post hoc Tukey tests. RESULTS: The independent factors (materials and solutions) significantly influenced the microhardness and color (p < 0.001). Ra of the materials was not affected by any of the mouthwashes (p > 0.05). The microhardness and color of each material varied significantly after immersion in PvP-I and HP (p < 0.05). The highest percentage change in microhardness, Ra, and ΔE was found in LU immersed in PvP-I and HP mouthwashes, while the lowest change was found in ENA groups (p < 0.05). CONCLUSION: Within the limitations of this study, it was found that the surface hardness and color of tested polymer-based composite CAD/CAM materials are susceptible to degradation and change after 30 days of immersion in 1% PvP-I and 1.5% HP mouthwashes.


Assuntos
Antivirais , Cerâmica , Dureza , Antissépticos Bucais , Propriedades de Superfície , Antissépticos Bucais/química , Antivirais/química , Cor , Teste de Materiais , Cetilpiridínio/química , Resinas Compostas/química , Humanos , Desenho Assistido por Computador , COVID-19 , Povidona-Iodo/química , Peróxido de Hidrogênio/química
2.
PLoS One ; 19(4): e0300696, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38603679

RESUMO

The primary treatment method for eradicating Helicobacter pylori (H. pylori) infection involves the use of antibiotic-based therapies. Due to the growing antibiotic resistance of H. pylori, there has been a surge of interest in exploring alternative therapies. Cetylpyridinium chloride (CPC) is a water-soluble and nonvolatile quaternary ammonium compound with exceptional broad-spectrum antibacterial properties. To date, there is no documented or described specific antibacterial action of CPC against H. pylori. Therefore, this study aimed to explore the in vitro activity of CPC against H. pylori and its potential antibacterial mechanism. CPC exhibited significant in vitro activity against H. pylori, with MICs ranging from 0.16 to 0.62 µg/mL and MBCs ranging from 0.31 to 1.24 µg/mL. CPC could result in morphological and physiological modifications in H. pylori, leading to the suppression of virulence and adherence genes expression, including flaA, flaB, babB, alpA, alpB, ureE, and ureF, and inhibition of urease activity. CPC has demonstrated in vitro activity against H. pylori by inhibiting its growth, inducing damage to the bacterial structure, reducing virulence and adherence factors expression, and inhibiting urease activity.


Assuntos
Infecções por Helicobacter , Helicobacter pylori , Humanos , Helicobacter pylori/genética , Cetilpiridínio/farmacologia , Urease/genética , Infecções por Helicobacter/microbiologia , Antibacterianos/farmacologia
3.
BMC Oral Health ; 24(1): 491, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38664718

RESUMO

BACKGROUND: Recent randomized clinical trials suggest that the effect of using cetylpyridinium chloride (CPC) mouthwashes on the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) viral load in COVID-19 patients has been inconsistent. Additionally, no clinical study has investigated the effectiveness of on-demand aqueous chlorine dioxide mouthwash against COVID-19. METHODS: We performed a randomized, placebo-controlled, open-label clinical trial to assess for any effects of using mouthwash on the salivary SARS-CoV-2 viral load among asymptomatic to mildly symptomatic adult COVID-19-positive patients. Patients were randomized to receive either 20 mL of 0.05% CPC, 10 mL of 0.01% on-demand aqueous chlorine dioxide, or 20 mL of placebo mouthwash (purified water) in a 1:1:1 ratio. The primary endpoint was the cycle threshold (Ct) values employed for SARS-CoV-2 salivary viral load estimation. We used linear mixed-effects models to assess for any effect of the mouthwashes on SARS-CoV-2 salivary viral load. RESULTS: Of a total of 96 eligible participants enrolled from November 7, 2022, to January 19, 2023, 90 were accepted for the primary analysis. The use of 0.05% CPC mouthwash was not shown to be superior to placebo in change from baseline salivary Ct value at 30 min (difference vs. placebo, 0.640; 95% confidence interval [CI], -1.425 to 2.706; P = 0.543); 2 h (difference vs. placebo, 1.158; 95% CI, -0.797 to 3.112; P = 0.246); 4 h (difference vs. placebo, 1.283; 95% CI, -0.719 to 3.285; P = 0.209); 10 h (difference vs. placebo, 0.304; 95% CI, -1.777 to 2.385; P = 0.775); or 24 h (difference vs. placebo, 0.782; 95% CI, -1.195 to 2.759; P = 0.438). The use of 0.01% on-demand aqueous chlorine dioxide mouthwash was also not shown to be superior to placebo in change from baseline salivary Ct value at 30 min (difference vs. placebo, 0.905; 95% CI, -1.079 to 2.888; P = 0.371); 2 h (difference vs. placebo, 0.709; 95% CI, -1.275 to 2.693; P = 0.483); 4 h (difference vs. placebo, 0.220; 95% CI, -1.787 to 2.226; P = 0.830); 10 h (difference vs. placebo, 0.198; 95% CI, -1.901 to 2.296; P = 0.854); or 24 h (difference vs. placebo, 0.784; 95% CI, -1.236 to 2.804; P = 0.447). CONCLUSIONS: In asymptomatic to mildly symptomatic adults with COVID-19, compared to placebo, the use of 0.05% CPC and 0.01% on-demand aqueous chlorine dioxide mouthwash did not lead to a significant reduction in SARS-CoV-2 salivary viral load. Future studies of the efficacy of CPC and on-demand aqueous chlorine dioxide mouthwash on the viral viability of SARS-CoV-2 should be conducted using different specimen types and in multiple populations and settings.


Assuntos
COVID-19 , Cetilpiridínio , Antissépticos Bucais , Saliva , Carga Viral , Humanos , Antissépticos Bucais/uso terapêutico , Carga Viral/efeitos dos fármacos , Saliva/virologia , Masculino , Feminino , Adulto , Cetilpiridínio/uso terapêutico , Pessoa de Meia-Idade , SARS-CoV-2 , Compostos Clorados/uso terapêutico , Compostos Clorados/farmacologia , Óxidos/uso terapêutico , Idoso
4.
J Appl Biomater Funct Mater ; 22: 22808000241236590, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38444166

RESUMO

OBJECTIVE: To evaluate the antitumor and antimicrobial properties of an alginate-based membrane (ABM) loaded with bismuth lipophilic nanoparticles (BisBAL NPs) and cetylpyridinium chloride (CPC) on clinically isolated bacteria and a pancreatic cancer cell line. MATERIAL AND METHODS: The BisBAL NP-CPC ABM was characterized using optical and scanning electron microscopy (SEM). The antimicrobial potential was measured using the disk-diffusion assay, and antibiofilm activity was determined through the live/dead assay and fluorescence microscopy. The antitumor activity was analyzed on the pancreatic cell line (Panc 03.27) using the MTT assay and live/dead assay with fluorescence microscopy. RESULTS: After a 24-h exposure (37°C, aerobic conditions), 5 µM BisBAL NP reduced the growth of K. pneumoniae by 77.9%, while 2.5 µM BisBAL NP inhibited the growth of Salmonella, E. faecalis and E. faecium by 82.9%, 82.6%, and 78%, respectively (p < 0.0001). The BisBAL NPs-CPC ABM (at a ratio of 10:1; 500 and 50 µM, respectively) inhibited the growth of all isolated bacteria, producing inhibition halos of 9.5, 11.2, 7, and 10.3 mm for K. pneumoniae, Salmonella, E. faecalis, and E. faecium, respectively, in contrast to the 6.5, 9.5, 8.5, and 9.8 mm obtained with 100 µM ceftriaxone (p < 0.0001). The BisBAL NPs-CPC ABM also reduced bacterial biofilms, with 81.4%, 74.5%, 97.1%, and 79.5% inhibition for K. pneumoniae, E. faecium, E. faecalis, and Salmonella, respectively. Furthermore, the BisBAL NPs-CPC ABM decreased Panc 03.27 cell growth by 76%, compared to 18% for drug-free ABM. GEM-ABM reduced tumoral growth by 73%. The live/dead assay confirmed that BisBAL NPs-CPC-ABM and GEM-ABM were cytotoxic for the turmoral Panc 03.27 cells. CONCLUSION: An alginate-based membrane loaded with BisBAL NP and CPC exhibits dual antimicrobial and antitumoral efficacy. Therefore, it could be applied in cancer treatment and to diminish the occurrence of surgical site infections.


Assuntos
Anti-Infecciosos , Bismuto , Dimercaprol/análogos & derivados , Compostos Organometálicos , Cetilpiridínio/farmacologia , Anti-Infecciosos/farmacologia , Alginatos/farmacologia , Klebsiella pneumoniae
5.
Food Chem Toxicol ; 186: 114547, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38408634

RESUMO

People are exposed to high concentrations of antibacterial agent cetylpyridinium chloride (CPC) via food and personal care products, despite little published information regarding CPC effects on eukaryotes. Here, we show that low-micromolar CPC exposure, which does not cause cell death, inhibits mitochondrial ATP production in primary human keratinocytes, mouse NIH-3T3 fibroblasts, and rat RBL-2H3 immune mast cells. ATP inhibition via CPC (EC50 1.7 µM) is nearly as potent as that caused by canonical mitotoxicant CCCP (EC50 1.2 µM). CPC inhibition of oxygen consumption rate (OCR) tracks with that of ATP: OCR is halved due to 1.75 µM CPC in RBL-2H3 cells and 1.25 µM in primary human keratinocytes. Mitochondrial [Ca2+] changes can cause mitochondrial dysfunction. Here we show that CPC causes mitochondrial Ca2+ efflux from mast cells via an ATP-inhibition mechanism. Using super-resolution microscopy (fluorescence photoactivation localization) in live cells, we have discovered that CPC causes mitochondrial nanostructural defects in live cells within 60 min, including the formation of spherical structures with donut-like cross section. This work reveals CPC as a mitotoxicant despite widespread use, highlighting the importance of further research into its toxicological safety.


Assuntos
Anti-Infecciosos Locais , Anti-Infecciosos , Camundongos , Humanos , Ratos , Animais , Cetilpiridínio/química , Cetilpiridínio/farmacologia , Roedores , Anti-Infecciosos/farmacologia , Mitocôndrias , Trifosfato de Adenosina
6.
PLoS One ; 19(2): e0297291, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38363760

RESUMO

BACKGROUND: The oral cavity is the site of entry and replication for many respiratory viruses. Furthermore, it is the source of droplets and aerosols that facilitate viral transmission. It is thought that appropriate oral hygiene that alters viral infectivity might reduce the spread of respiratory viruses and contribute to infection control. MATERIALS AND METHODS: Here, we analyzed the antiviral activity of cetylpyridinium chloride (CPC), chlorhexidine (CHX), and three commercial CPC and CHX-containing mouthwash preparations against the Influenza A virus and the Respiratory syncytial virus. To do so the aforementioned compounds and preparations were incubated with the Influenza A virus or with the Respiratory syncytial virus. Next, we analyzed the viability of the treated viral particles. RESULTS: Our results indicate that CPC and CHX decrease the infectivity of both the Influenza A virus and the Respiratory Syncytial virus in vitro between 90 and 99.9% depending on the concentration. Likewise, CPC and CHX-containing mouthwash preparations were up to 99.99% effective in decreasing the viral viability of both the Influenza A virus and the Respiratory syncytial virus in vitro. CONCLUSION: The use of a mouthwash containing CPC or CHX alone or in combination might represent a cost-effective measure to limit infection and spread of enveloped respiratory viruses infecting the oral cavity, aiding in reducing viral transmission. Our findings may stimulate future clinical studies to evaluate the effects of CPC and CHX in reducing viral respiratory transmissions.


Assuntos
Anti-Infecciosos Locais , Vírus da Influenza A , Clorexidina , Antissépticos Bucais , Cetilpiridínio/farmacologia , Vírus Sinciciais Respiratórios , Antivirais/farmacologia
7.
Microbiol Spectr ; 12(3): e0271223, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38240572

RESUMO

Management of urinary tract infection (UTI) in postmenopausal women can be challenging. The recent rise in resistance to most of the available oral antibiotic options together with high recurrence rate in postmenopausal women has further complicated treatment of UTI. As such, intravesical instillations of antibiotics like gentamicin are being investigated as an alternative to oral antibiotic therapies. This study evaluates the efficacy of the candidate intravesical therapeutic VesiX, a solution containing the cationic detergent Cetylpyridinium chloride, against a broad range of uropathogenic bacterial species clinically isolated from postmenopausal women with recurrent UTI (rUTI). We also evaluate the cytotoxicity of VesiX against cultured bladder epithelial cells and find that low concentrations of 0.0063% and 0.0125% provide significant bactericidal effect toward diverse bacterial species including uropathogenic Escherichia coli (UPEC), Klebsiella pneumoniae, Enterococcus faecalis, Pseudomonas aeruginosa, and Proteus mirabilis while minimizing cytotoxic effects against cultured 5637 bladder epithelial cells. Lastly, to begin to evaluate the potential utility of using VesiX in combination therapy with existing intravesical therapies for rUTI, we investigate the combined effects of VesiX and the intravesical antibiotic gentamicin. We find that VesiX and gentamicin are not antagonistic and are able to reduce levels of intracellular UPEC in cultured bladder epithelial cells. IMPORTANCE: When urinary tract infections (UTIs), which affect over 50% of women, become resistant to available antibiotic therapies dangerous complications like kidney infection and lethal sepsis can occur. New therapeutic paradigms are needed to expand our arsenal against these difficult to manage infections. Our study investigates VesiX, a Cetylpyridinium chloride (CPC)-based therapeutic, as a candidate broad-spectrum antimicrobial agent for use in bladder instillation therapy for antibiotic-resistant UTI. CPC is a cationic surfactant that is FDA-approved for use in mouthwashes and is used as a food additive but has not been extensively evaluated as a UTI therapeutic. Our study is the first to investigate its rapid bactericidal kinetics against diverse uropathogenic bacterial species isolated from postmenopausal women with recurrent UTI and host cytotoxicity. We also report that together with the FDA-approved bladder-instillation agent gentamicin, VesiX was able to significantly reduce intracellular populations of uropathogenic bacteria in cultured bladder epithelial cells.


Assuntos
Infecções por Escherichia coli , Infecções Urinárias , Escherichia coli Uropatogênica , Humanos , Feminino , Bexiga Urinária/microbiologia , Cetilpiridínio/farmacologia , Cetilpiridínio/uso terapêutico , Antibacterianos/uso terapêutico , Infecções Urinárias/tratamento farmacológico , Infecções Urinárias/microbiologia , Gentamicinas/farmacologia , Gentamicinas/uso terapêutico , Células Epiteliais , Infecções por Escherichia coli/microbiologia
8.
J Hazard Mater ; 465: 133402, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38183937

RESUMO

Soils contaminated by per- and polyfluoroalkyl substances (PFAS) present a significant threat to both ecological and human health. Extensive research efforts are currently underway to develop effective strategies for immobilizing these chemicals in soils. In this study, calcium montmorillonite was modified with cetylpyridinium chloride (CPC-CM) to enhance its electrostatic and hydrophobic interactions with PFAS. CPC-CM exhibited high adsorption for perfluorooctanoate acid (PFOA), perfluorooctane sulfonate (PFOS) and 8:2 fluorotelomer sulfonic acids (8:2 FTSA) across initial concentrations of 50-1000 µg/L, outperforming both the parent CM and L-carnitine modified CM. Soil leaching tests demonstrated the superior immobilization capabilities of the CPC-CM, maintaining an average PFAS leaching rate below 7% after 120-day incubation. In the context of human exposure scenarios, the in vitro bioaccessibility and in vivo bioavailability of PFAS in soils were measured by gastrointestinal extraction and mouse assay. CPC-CM treatment effectively reduced the bioaccessibility (by up to 84%) and bioavailability (by up to 76%) of PFAS in soils. Furthermore, the safety and efficacy of CPC-CM were evaluated using enteric microorganisms of mice. CPC-CM treatment mitigated PFAS-induced changes in the abundance of Bacteroidetes and Firmicutes, thereby reducing PFAS-induced health risks for humans. Overall, CPC-CM synthesized in this study demonstrated superior adsorption performance and application safety, offering a highly promising approach for remediating PFAS-contaminated soil.


Assuntos
Ácidos Alcanossulfônicos , Fluorocarbonos , Humanos , Animais , Camundongos , Argila , Cetilpiridínio , Solo/química , Bentonita , Disponibilidade Biológica
9.
J Clin Periodontol ; 51(2): 158-166, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38058254

RESUMO

AIM: This study aimed at investigating the efficacy of a 0.05% cetylpyridinium chloride-0.05% chlorhexidine (CPC-CHX) mouthwash in reducing viral load in the saliva as compared with sterile water. MATERIALS AND METHODS: Forty SARS-CoV-2 positive patients were asked to dispense 4 mL of saliva. Half the patients rinsed for 60 s with 15 mL CPC-CHX, and the remaining patients rinsed with sterile water (control). Four millilitres of saliva were collected after 15, 30 and 60 min after rinsing. Quantitative reverse transcriptase polymerase chain reaction (RT-qPCR) and enzyme-linked immunosorbent assay (ELISA) specific for SARS-CoV-2 nucleocapsid protein were performed. For ELISA, the intact (representing the active virus) to total virus load (I/T) was calculated. RESULTS: SARS-CoV-2 copy numbers/mL from RT-qPCR tended to decrease in the control group, whereas in the CPC-CHX group, an increase was observed after T30. However, mixed linear model analysis revealed no statistical differences between groups (p = .124), time points (p = .616) and vaccinated or non-vaccinated patients (p = .953). Similarly, no impact of group (p = .880), time points (p = .306) and vaccination (p = .711) was observed for I/T ratio values. CONCLUSIONS: Within the limitation of this study, there was no evidence that the intervention reduced salivary SARS-CoV-2 viral load during the course of 60 min. Therefore, commonly used pre-procedural rinsing might not be clinically relevant.


Assuntos
Antivirais , COVID-19 , Antissépticos Bucais , Humanos , Antivirais/uso terapêutico , Cetilpiridínio/uso terapêutico , Clorexidina/uso terapêutico , COVID-19/prevenção & controle , Método Duplo-Cego , Antissépticos Bucais/uso terapêutico , Saliva , SARS-CoV-2 , Água
10.
Int Dent J ; 74(2): 260-267, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37839955

RESUMO

AIM: The primary objective of this work was to assess total soluble fluoride (TSF), pH values, and titratable acidity (TA) of various mouthwashes "in vitro," and the second was to compare fluoride content on labels with measured TSF. METHODS: Commercial mouthwashes were collected and analysed. Company, type, manufacturer data, and active ingredients (essential oils [EO], cetylpyridinium chloride [CPC], chlorhexidine [CHX], and fluoride) were described. TSF, pH, and TA capacity were measured. Descriptive quantitative analysis were performed per mouthwash. RESULTS: In total, 54 mouthwashes from 20 brands were included. These included mouthwashes with the active ingredients EO (n = 11), CPC (n = 17), CHX (n = 18), and fluoride (n = 32); 27 mouthwashes with more than 1 of these active ingredients; and 4 with none of the above-mentioned ingredients. Fluoride was present in different formulations; most contained sodium fluoride (NaF), and a few had sodium monofluorophosphate and amine fluoride + NaF. The pH values of all evaluated mouthwashes ranged from 4.1 to 7.9. Twenty mouthwashes presented pHs below 5.5, of which 10 contained fluoride. TA ranged from 0 to 48. According to the manufacturer data, mouthwashes with fluoride had concentrations from 217 to 450 ppm, with 90% in the range from 217 to 254 ppm. Laboratory data revealed that TSF ranged from 229 to 500 ppm, with 90% in the range from 229 to 337 ppm. A statistically significant difference was observed between measured TSF and the labelled fluoride content on the packaging of the fluoride mouthwashes (mean difference, 43.92 ± 34.34; P < .001). Most of these mouthwashes contained at least the amount of fluoride as mentioned on the packaging (93%). CONCLUSION: The pH values and TA of commercially available mouthwashes showed a large variation. TSF levels of the fluoride mouthwashes were found to be at least the amount of fluoride as labelled. Dental care professionals should be aware of the pH, TA, fluoride content, and other active ingredients of different mouthwashes to better understand their potential impact on oral health.


Assuntos
Anti-Infecciosos Locais , Placa Dentária , Humanos , Antissépticos Bucais , Cetilpiridínio , Fluoretos , Método Duplo-Cego , Clorexidina , Fluoreto de Sódio
11.
Am J Orthod Dentofacial Orthop ; 165(2): 173-185, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37906245

RESUMO

INTRODUCTION: Effective aligner hygiene is recognized as an important part of orthodontic treatments and oral hygiene. However, there is no effective cleansing method for removable aligners. METHODS: In this study, we incorporated tannic acid (TA) with cetylpyridinium chloride (CPC) to develop the TA-CPC complex. The antibacterial properties of 15.8 mg/mL TA-CPC against Escherichia coli and Staphylococcus aureus were evaluated in vitro, which were compared with 5.1 mg/mL TA, 10.7 mg/mL CPC, a commercial denture cleansing solution (YA; 15 mg/mL), and water. As for the assessment of stain-removal ability, the aligners stained by coffee were soaked in cleansing solutions, and the color changes (ΔE∗) were calculated on the basis of the CIE L∗a∗b∗ color system, and the National Bureau of Standards system was used for the clinical interpretation of the color change. Atomic force microscope examination, tensile property assessment, and wavelength dispersive x-ray fluorescence analysis were performed to investigate the material compatibility of TA-CPC, and Cell Counting Kit-8 assay and live/dead assay were used to test the cytotoxicity of TA-CPC. RESULTS: The results showed that TA-CPC had a positive zeta-potential, and cation-π interaction changed the chemical environments of the phenyl group in TA-CPC, resulting in greater inhibition zones of S. aureus and E. coli than other cleaners. The quantification of the biofilm biomass and the fluorescent intensities also reflected that the TA-CPC solution exhibited better antibacterial ability. As for the ability of stain removal, ΔE∗ value of group TA-CPC was 2.84 ± 0.55, whereas those of stained aligners immersed with deionized distilled water, TA, YA, and CPC were 10.26 ± 0.04, 9.54 ± 0.24, 5.93 ± 0.36, and 4.69 ± 0.35, respectively. The visual inspection and National Bureau of Standards ratings also showed that the color of stained aligners cleansed by TA-CPC was much lighter than those of the other groups. Meanwhile, TA-CPC had good compatibility with the aligner material and cells. CONCLUSIONS: TA-CPC is a promising strategy to inhibit the formation of biofilms and remove the stains on the aligners safely, which may disinfect the aligners to improve oral health and help keep the transparent appearances of aligners without impacting the morphology and mechanical properties.


Assuntos
Cetilpiridínio , Corantes , Polifenóis , Humanos , Cetilpiridínio/farmacologia , Corantes/farmacologia , Escherichia coli , Staphylococcus aureus , Antibacterianos/farmacologia , Água/farmacologia
12.
Clin Exp Dent Res ; 9(6): 1034-1043, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-38041504

RESUMO

OBJECTIVES: This study explored the changes in bacterial flora composition and total bacterial count in the saliva and tongue coating, along with the change in the tongue coating index (TCI) following an intervention with 0.3% cetylpyridinium chloride (CPC) mouth spray after professional oral care. MATERIALS AND METHODS: Fifty-two adult volunteers aged 30-60 years were equally divided into CPC spray (n = 26) and control (n = 26) groups. All subjects underwent scaling and polishing. The CPC spray group was administered four puffs of CPC spray to the tongue dorsum four times a day for 3 weeks. The control group performed only routine daily oral care (brushing) and did not use any other spray. Bacteriological evaluation of saliva and tongue coating was performed using 16S ribosomal RNA gene sequencing and quantitative polymerase chain reaction. The tongue coating was evaluated to calculate the TCI. A per-protocol analysis was conducted for 44 subjects (CPC spray group, n = 23; control group, n = 21). RESULTS: At 1 and 3 weeks after CPC spray use, the flora of the saliva and tongue coating changed; the genus Haemophilus was dominant in the CPC spray group, whereas the genus Saccharibacteria was dominant in the control group. The sampling time differed among individual participants, which may have affected the bacterial counts. There was no significant intragroup change in TCI in either group. CONCLUSIONS: CPC spray affected the bacterial flora in the saliva and tongue coating, particularly with respect to an increase in the abundance of Haemophilus. However, CPC spray did not change the TCI. These results suggest that it may be optimal to combine CPC spray with a physical cleaning method such as using a tongue brush or scraper. Clinical Trial Registration: University Hospital Medical Information Network UMIN000041140.


Assuntos
Anti-Infecciosos Locais , Placa Dentária , Adulto , Humanos , Cetilpiridínio , Antissépticos Bucais , Placa Dentária/microbiologia , Língua/microbiologia , Método Duplo-Cego , Voluntários
13.
Odovtos (En línea) ; 25(3): 18-31, Sep.-Dec. 2023. tab, graf
Artigo em Inglês | LILACS, SaludCR | ID: biblio-1529066

RESUMO

Abstract The present research aims to determine the antimicrobial efficacy of the mouthwashes based on cetylpyridinium chloride (CPC), before aerosol producing dental procedures. A data search was performed during August 2021 in five databases MEDLINE (PubMed), SCOPUS, SCIELO, Cochrane Central Register of Controlled Trials (CENTRAL) and Google Scholar. Randomized clinical trials (RCTs) were included based on the PICO question, comparing the efficacy of the mouthwashes based on cetylpyridinium chloride (CPC), versus other mouthwashes and water, before aerosol producing dental procedures, papers in English, Spanish and Portuguese were included without time limits. The risk of the included studies was evaluated with the tool RoB 2.0. Number of registration PROSPERO N° CRD42021275982. 120 papers were obtained in the preliminary search, discarding those that didn't comply with the selection criteria, leaving only 3 studies. These papers reported the use of cetylpyridinium chloride (CPC) was effective for the reduction of bacteria during the ultrasonic prophylactic procedure. The use of CPC mouthwashes previous to the dental treatment with ultrasonic prophylaxis showed only antibacterial capacity.


Resumen El presente trabajo de investigación tiene como objetivo determinar la eficacia antimicrobiana de los colutorios a base de cloruro de Cetilpiridinio (CPC), previo a tratamientos dentales que generen aerosol. Se realizó una búsqueda bibliográfica hasta agosto del 2021 en cinco bases de datos: MEDLINE (vía PubMed), SCOPUS, SCIELO, Cochrane Central Register of Controlled Trials (CENTRAL) y Google Scholar. Se incluyeron ensayos clínicos aleatorizados (ECAs), basándose en la pregunta PICOS, que compare la eficacia del colutorio a base de cloruro de Cetilpiridinio (CPC) con otro colutorio, placebo o agua, previo a un tratamiento dental que genere aerosol, en los idiomas español, inglés o portugués y sin límite de tiempo. El riesgo de los estudios incluidos se evaluó con la herramienta RoB 2.0. Número de registro PROSPERO N° CRD42021275982. Se obtuvo un total de 120 artículos en la búsqueda preliminar, descartando aquellos que no cumplían con los criterios de selección, quedando sólo 3articulos. Estos artículos informaron que el uso de CPC es efectivo para la reducción de bacterias durante el procedimiento de profilaxis con ultrasonido. El uso de los enjuagues bucales a base de CPC previo al tratamiento dental de profilaxis con ultrasonido sólo tiene eficacia antibacteriana.


Assuntos
Cetilpiridínio/análise , Antibacterianos/uso terapêutico , Antissépticos Bucais/análise
14.
PLoS One ; 18(12): e0293549, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38127975

RESUMO

To provide the poultry industry with effective mitigation strategies, the effects of cetylpyridinium chloride (CPC) on the reduction of Salmonella Infantis, hilA expression, and chicken skin microbiota were evaluated. Chicken breast skins (4×4 cm; N = 100, n = 10, k = 5) were inoculated with Salmonella (Typhimurium or Infantis) at 4°C (30min) to obtain 108 CFU/g attachment. Skins were shaken (30s), with remaining bacteria being considered firmly attached. Treatments were applied as 30s dips in 50 mL: no inocula-no-treatment control (NINTC), no treatment control (NTC), tap water (TW), TW+600 ppm PAA (PAA), or TW+0.5% CPC (CPC). Excess fluid was shaken off (30s). Samples were homogenized in nBPW (1 min). Samples were discarded. Salmonella was enumerated and Log10 transformed. Reverse transcriptase-qPCR (rt-qPCR) was performed targeting hilA gene and normalized using the 2-ΔΔCt method. Data were analyzed using one-way ANOVA in RStudio with means separated by Tukey's HSD (P≤0.05). Genomic DNA of rinsates was extracted, 16S rRNA gene (V4) was sequenced (MiSeq), and data analyzed in QIIME2 (P≤0.05 and Q≤0.05). CPC and PAA affected Salmonella levels differently with CPC being effective against S. Infantis compared to TW (P<0.05). Treatment with CPC on S. Infantis-infected skin altered the hilA expression compared to TW (P<0.05). When inoculated with S. Typhimurium, there was no difference between the microbiota diversity of skins treated with PAA and CPC; however, when inoculated with S. Infantis, there was a difference in the Shannon's Entropy and Jaccard Dissimilarity between the two treatments (P<0.05). Using ANCOM at the genus level, Brochothrix was significant (W = 118) among skin inoculated with S. Typhimurium. Among S. Infantis inoculated, Yersiniaceae, Enterobacterales, Lachnospiraceae CHKCI001, Clostridia vadinBB60 group, Leuconostoc, Campylobacter, and bacteria were significant (408). CPC and PAA-treated skins had lowest relative abundance of the genera. In conclusion, CPC mitigated Salmonella Infantis, altered hilA expression, and influenced the chicken skin microbiota.


Assuntos
Cetilpiridínio , Aves Domésticas , Animais , Cetilpiridínio/farmacologia , RNA Ribossômico 16S/genética , Galinhas/microbiologia , Microbiologia de Alimentos , Salmonella typhimurium
15.
PeerJ ; 11: e15080, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38130922

RESUMO

Background: Symptomatic patients with COVID-19 typically have a high SARS-CoV-2 viral load in their saliva. Procedures to reduce the viral load in their oral cavity are important for mitigating the viral transmission. Methods: This randomized clinical trial investigated the impact of two mouthwashes (0.075% cetylpyridinium chloride plus 0.28% zinc lactate (CPC+Zn) (n = 32), and 0.075% cetylpyridinium chloride (CPC) (n = 31)) on the viral load of SARS-CoV-2 in saliva when compared to the distilled water negative control (n = 32). Saliva was collected before (T0) and after (5 min, T1; 30 min, T2; and 60 min, T3) the intervention. Viral load in saliva was measured by qRT-PCR assays. The data in both groups was normalized for T0 and Negative Control, resulting in fold change values. Results: CPC+Zn oral solution reduced the viral load in saliva by 6.34-fold at T1, 3.6-fold at T2 and 1.9-fold at T3. Rinsing with the CPC mouthwash reduced the viral load in saliva by 2.5-fold at T1, 1.9-fold at T2 and 2.0-fold at T3. Conclusion: CPC+Zn mouthwash or with the CPC mouthwash reduced the viral load in saliva of COVID-19 patients immediately after rinsing. These reductions extended up to 60 min.


Assuntos
Anti-Infecciosos Locais , COVID-19 , Humanos , Cetilpiridínio , Antissépticos Bucais , Saliva , SARS-CoV-2 , Carga Viral
16.
Clin Exp Dent Res ; 9(6): 1044-1050, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-38018029

RESUMO

OBJECTIVES: Maxillomandibular fixation requires the jawbones to remain static. Mechanical cleaning is also carried out by brushing or with a water flosser to maintain the oral cavity in a hygienic state, but this cannot be considered sufficient. Mouthwashes are used as a substitute for mechanical cleaning or in a supplementary role after such cleaning. The aim is to evaluate the effectiveness of HABITPRO mouthwash, which contains cetylpyridinium chloride, dipotassium glycyrrhizinate, and tranexamic acid in the specific environment created by maxillomandibular fixation used as an adjunct to mechanical cleaning. MATERIAL AND METHODS: A total of 55 patients who had undergone maxillomandibular fixation were randomly allocated to either a HABITPRO group (n = 29) or a placebo group (n = 26). To investigate their oral hygiene status, their plaque control record (PCR) was reviewed, and the caries-related bacterial counts, pH, acid buffering capacity, white blood cell count, and ammonia in saliva were measured immediately before maxillomandibular fixation, on Day 10 of fixation, and immediately after fixation was released. RESULTS: After approximately 2-3 weeks of mouthwash use, the PCR index also increased significantly in the placebo group compared with baseline, whereas it remained almost steady in the HABITPRO group. Additionally, salivary ammonia levels decreased significantly in the HABITPRO group compared to that of the placebo group. CONCLUSIONS: Even with maxillomandibular fixation, continued gargling with HABITPRO mouthwash in the perioperative period as an adjunct to mechanical cleaning can help maintain better oral hygiene and reduce bacterial counts.


Assuntos
Anti-Infecciosos Locais , Ácido Tranexâmico , Humanos , Cetilpiridínio/uso terapêutico , Antissépticos Bucais/uso terapêutico , Higiene Bucal , Anti-Infecciosos Locais/uso terapêutico , Ácido Glicirrízico , Amônia , Técnicas de Fixação da Arcada Osseodentária
17.
Environ Toxicol Pharmacol ; 102: 104239, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37541639

RESUMO

Cetylpyridinium Chloride (CPC) is a common disinfectant with potential mitochondrial toxicity. However, the effects of CPC on female reproduction remains unclear. In the present study, pregnant mice were exposed to environmentally relevant doses of CPC for 3 days, the effects were evaluated in the female offspring. Maternal exposure to CPC caused loss of oocytes in neonatal ovaries. TEM analysis of neonatal ovaries showed CPC caused aberrant mitochondrial morphology including vacuolated and disorganized structure, reduced functional cristae. In addition, CPC decreased mitochondrial membrane potential in neonatal oocytes. Seahorse analysis showed that CPC hampered mitochondrial reserve, manifested as reduced spare respiratory capacity. Furthermore, CPC damaged mitochondrial function and impaired developmental competence of MII oocytes, suggesting a persisting impact into adulthood. In summary, this is the first known demonstration that maternal exposure to CPC caused mitochondrial disorders in neonatal ovaries and had long-term effects on fertility of the female offspring.


Assuntos
Cetilpiridínio , Exposição Materna , Gravidez , Humanos , Camundongos , Feminino , Animais , Cetilpiridínio/farmacologia , Cetilpiridínio/toxicidade , Exposição Materna/efeitos adversos , Oogênese , Oócitos , Mitocôndrias
18.
Food Chem Toxicol ; 179: 113980, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37549805

RESUMO

Cetylpyridinium chloride (CPC) is an antimicrobial used in numerous personal care and janitorial products and food for human consumption at millimolar concentrations. Minimal information exists on the eukaryotic toxicology of CPC. We have investigated the effects of CPC on signal transduction of the immune cell type mast cells. Here, we show that CPC inhibits the mast cell function degranulation with antigen dose-dependence and at non-cytotoxic doses ∼1000-fold lower than concentrations in consumer products. Previously we showed that CPC disrupts phosphatidylinositol 4,5-bisphosphate, a signaling lipid critical for store-operated Ca2+ entry (SOCE), which mediates degranulation. Our results indicate that CPC inhibits antigen-stimulated SOCE: CPC restricts Ca2+ efflux from endoplasmic reticulum, reduces Ca2+ uptake into mitochondria, and dampens Ca2+ flow through plasma membrane channels. While inhibition of Ca2+ channel function can be caused by alteration of plasma membrane potential (PMP) and cytosolic pH, CPC does not affect PMP or pH. Inhibition of SOCE is known to depress microtubule polymerization, and here we show that CPC indeed dose-dependently shuts down formation of microtubule tracks. In vitro data reveal that CPC inhibition of microtubules is not due to direct CPC interference with tubulin. In summary, CPC is a signaling toxicant that targets Ca2+ mobilization.


Assuntos
Cetilpiridínio , Mastócitos , Humanos , Cetilpiridínio/metabolismo , Cetilpiridínio/farmacologia , Cálcio/metabolismo , Transdução de Sinais , Preparações Farmacêuticas/metabolismo , Sinalização do Cálcio
19.
Viruses ; 15(7)2023 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-37515121

RESUMO

The oral cavity is particularly susceptible to viral infections that are self-recovering in most cases. However, complications may appear in severe cases and/or immunocompromised subjects. Cetylpyridinium chloride (CPC)-containing mouthwashes are able to decrease the infectivity of the SARS-CoV-2 virus by disrupting the integrity of the viral envelope. Here, we show that CPC, as the active ingredient contained in commercialized, exerts significant antiviral activity against enveloped viruses, such as HSV-1, but not against non-enveloped viruses, such as HPV. CPC-containing mouthwashes have been used as antiseptics for decades, and thus, they can represent a cost-effective measure to limit infection and spread of enveloped viruses infecting the oral cavity, aiding in reducing viral transmission.


Assuntos
Anti-Infecciosos Locais , COVID-19 , Herpesvirus Humano 1 , Humanos , Antissépticos Bucais/farmacologia , Cetilpiridínio/farmacologia , SARS-CoV-2 , Anti-Infecciosos Locais/farmacologia
20.
J Mater Chem B ; 11(22): 4899-4913, 2023 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-37191118

RESUMO

Photodynamic therapy (PDT) is facing challenges such as poor solubility, precise delivery, self-aggregation, and photobleaching of photosensitizers with cancer cells due to their less tendency to accumulate in tumor tissues. To address these challenges, we have explored a Rose Bengal (RB)-loaded metallocatanionic vesicles (MCVs) nanosystem for the phototoxicity of cancer cells. Different sets of MCVs were prepared by two different cationic single-chain metallosurfactants, i.e., hexadecylpyridinium trichlorocuprate (CuCPC I) and hexadecylpyridinium trichloroferrate (FeCPC I) in combination with anionic double-chain sodium bis(2-ethylhexyl)sulfosuccinate (AOT) surfactant in phosphate buffer saline of pH 7.4. The RB-loaded CuCPC I:AOT and FeCPC I:AOT vesicles enhanced the maximum singlet oxygen (1O2) generation by 1-fold and 3-fold, respectively, compared to pure RB. Upon irradiation with a 532 nm laser for 10 min, these RB-loaded CuCPC I:AOT and FeCPC I:AOT MCVs significantly decreased the metabolic activity of U-251 cells by 70% and 85% at MCVs concentration of 0.75 µM, respectively. Furthermore, RB-loaded MCVs showed the highest intracellular 1O2-mediated membrane damage and cell-killing effect as confirmed by singlet oxygen sensor green and differential nuclear staining assay, which is attributed to the cellular uptake profile of different RB-loaded MCVs fractions. Caspase 3/7 assay confirmed the apoptotic pathway of cell death by activating caspase. Therefore, the photoactivation of RB-loaded MCVs led to a significant reduction in the viability of U-251 cells (maximum 85%), which resulted in cell death. Our study demonstrated the advantage of using these dual-charge and biocompatible metallocatanionic vesicles as a promising delivery system of photodynamic therapy that can enhance 1O2 generation from PS and can be further utilized in photomedicine.


Assuntos
Neoplasias , Fotoquimioterapia , Rosa Bengala/farmacologia , Oxigênio Singlete/metabolismo , Cetilpiridínio , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Neoplasias/tratamento farmacológico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...