Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.099
Filtrar
2.
N Engl J Med ; 390(15): 1382-1393, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38587239

RESUMO

BACKGROUND: The effects of temporary mechanical circulatory support with a microaxial flow pump on mortality among patients with ST-segment elevation myocardial infarction (STEMI) complicated by cardiogenic shock remains unclear. METHODS: In an international, multicenter, randomized trial, we assigned patients with STEMI and cardiogenic shock to receive a microaxial flow pump (Impella CP) plus standard care or standard care alone. The primary end point was death from any cause at 180 days. A composite safety end point was severe bleeding, limb ischemia, hemolysis, device failure, or worsening aortic regurgitation. RESULTS: A total of 360 patients underwent randomization, of whom 355 were included in the final analysis (179 in the microaxial-flow-pump group and 176 in the standard-care group). The median age of the patients was 67 years, and 79.2% were men. Death from any cause occurred in 82 of 179 patients (45.8%) in the microaxial-flow-pump group and in 103 of 176 patients (58.5%) in the standard-care group (hazard ratio, 0.74; 95% confidence interval [CI], 0.55 to 0.99; P = 0.04). A composite safety end-point event occurred in 43 patients (24.0%) in the microaxial-flow-pump group and in 11 (6.2%) in the standard-care group (relative risk, 4.74; 95% CI, 2.36 to 9.55). Renal-replacement therapy was administered to 75 patients (41.9%) in the microaxial-flow-pump group and to 47 patients (26.7%) in the standard-care group (relative risk, 1.98; 95% CI, 1.27 to 3.09). CONCLUSIONS: The routine use of a microaxial flow pump with standard care in the treatment of patients with STEMI-related cardiogenic shock led to a lower risk of death from any cause at 180 days than standard care alone. The incidence of a composite of adverse events was higher with the use of the microaxial flow pump. (Funded by the Danish Heart Foundation and Abiomed; DanGer Shock ClinicalTrials.gov number, NCT01633502.).


Assuntos
Coração Auxiliar , Infarto do Miocárdio com Supradesnível do Segmento ST , Choque Cardiogênico , Idoso , Feminino , Humanos , Masculino , Coração Auxiliar/efeitos adversos , Incidência , Choque Cardiogênico/etiologia , Choque Cardiogênico/mortalidade , Choque Cardiogênico/cirurgia , Infarto do Miocárdio com Supradesnível do Segmento ST/complicações , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Resultado do Tratamento , Circulação Assistida/efeitos adversos , Circulação Assistida/instrumentação , Circulação Assistida/métodos
3.
Heart Lung Circ ; 33(4): 460-469, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38388259

RESUMO

BACKGROUND: The Impella (Abiomed, Danvers, MA, USA) temporary percutaneous left ventricular assist device is increasingly used as mechanical circulatory support in patients with acute myocardial infarction-cardiogenic shock (AMICS) or those undergoing high-risk protected percutaneous coronary intervention (PCI). The optimal weaning regimen remains to be defined. METHOD: We implemented a structured weaning protocol in a series of 10 consecutive patients receiving Impella support for protected PCI or AMICS treated with PCI in a high volume non-cardiac surgery centre. Weaning after revascularisation was titrated to native heart recovery using both haemodynamic and echocardiographic parameters. RESULTS: Ten patients (eight male, two female; aged 43-70 years) received Impella support for AMICS (80%) or protected PCI (20%). Cardiogenic shock was of Society for Cardiac Angiography & Interventions grade C-E of severity in 80%, and median left ventricular end-diastolic pressure was 31 mmHg. Protocol implementation allowed successful weaning in eight of 10 patients with a median support time of 29 hours (range, 4-48 hours). Explantation was associated with an increase in heart rate (81 vs 88 bpm; p=0.005), but no significant change in Cardiac Index (2.9 vs 2.9 L/min/m2), mean arterial pressure (79 vs 82 mmHg), vasopressor requirement (10% vs 10%), or serum lactate (1.0 vs 1.0). Median durations of intensive care and hospital stay were 3 and 6 days, respectively. At 30 days, the mortality rate was 20%, with median left ventricular ejection fraction of 40%. CONCLUSIONS: A structured and dynamic weaning protocol for patients with AMICS and protected PCI supported by the Impella device is feasible in a non-cardiac surgery centre. Larger studies are needed to assess generalisability of such a weaning protocol.


Assuntos
Coração Auxiliar , Infarto do Miocárdio , Intervenção Coronária Percutânea , Choque Cardiogênico , Humanos , Masculino , Choque Cardiogênico/terapia , Choque Cardiogênico/cirurgia , Feminino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Idoso , Adulto , Infarto do Miocárdio/complicações , Função Ventricular Esquerda/fisiologia , Estudos Retrospectivos , Ecocardiografia , Seguimentos
4.
J Invasive Cardiol ; 36(2)2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38335506

RESUMO

OBJECTIVES: The Impella (Abiomed) is a widely used percutaneous mechanical circulatory support device for high-risk percutaneous coronary intervention in patients with cardiogenic shock. This study aimed to determine the safety and feasibility of a non-angio-guided post-closure approach using the Perclose ProGlide (Abbott) to decannulate the Impella in the intensive care unit. METHODS: This retrospective study included consecutive patients who were successfully weaned from mechanical circulatory support using the Impella device between April 2019 and April 2022 at Hamamatsu University School of Medicine. Fifteen patients underwent complete post-closure of the femoral artery access sites at the bedside. Technical success of the post-closure hemostasis technique was defined as no evidence of bleeding or additional medical procedures after manual compression. The safety endpoints comprised the Valve Academic Research Consortium-3 and Bleeding Academic Research Consortium criteria. RESULTS: All patients achieved successful hemostasis with this novel technique without surgical conversion. There was no significant bleeding; however, procedure-related vessel occlusion was observed in 1 patient who was recanalized with balloon angioplasty. CONCLUSIONS: Bedside post-closure using the Perclose ProGlide device is a safe and feasible alternative to manual compression and surgical removal of the Impella device with low bleeding or vascular complications rates.


Assuntos
Angioplastia Coronária com Balão , Coração Auxiliar , Intervenção Coronária Percutânea , Humanos , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/cirurgia , Estudos Retrospectivos , Estudos de Viabilidade , Hemorragia , Resultado do Tratamento
5.
J Cardiothorac Surg ; 19(1): 42, 2024 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-38308328

RESUMO

Temporary mechanical circulatory support is a treatment of choice for patients in severe cardiogenic shock. Combining veno-arterial extracorporeal life support (ECLS) with devices that enable left ventricular unloading emerges as a promising strategy to diminish detrimental effect of elevated left ventricular afterload and to improve survival. However, the need to establish multiple arterial access sites remains a major drawback of this approach due to a significant rate of vascular complications. We describe herein a case of a single arterial access for ECLS and intra-aortic balloon pump using axillary artery that may provide a simple, modular and flexible approach for escalation or de-escalation of mechanical circulatory support.


Assuntos
Oxigenação por Membrana Extracorpórea , Coração Auxiliar , Humanos , Choque Cardiogênico/cirurgia , Choque Cardiogênico/etiologia , Oxigenação por Membrana Extracorpórea/métodos , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Artéria Axilar , Balão Intra-Aórtico/efeitos adversos , Coração Auxiliar/efeitos adversos
7.
Transplant Proc ; 56(1): 145-147, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38171989

RESUMO

The use of temporary mechanical circulatory support in cardiogenic shock (CS) is increasing. The Impella (Abiomed) is a percutaneous, microaxial ventricular assist device approved for short-term use in CS that can be implanted peripherally. Direct aortic placement is an alternative commonly performed when the sternum is open, for example, in post-cardiotomy shock or when the peripheral vasculature is of insufficient size or quality for implantation. Herein, we describe direct aortic implantation of the Impella 5.5 via right mini-thoracotomy for a patient in CS secondary to decompensated heart failure as a bridge to candidacy and, ultimately, transplantation.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Coração Auxiliar/efeitos adversos , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/complicações , Choque Cardiogênico/etiologia , Choque Cardiogênico/cirurgia , Aorta , Resultado do Tratamento , Estudos Retrospectivos
8.
Br J Surg ; 111(1)2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38230762

RESUMO

BACKGROUND: Surgical pulmonary embolectomy is rarely used for the treatment of massive acute pulmonary embolism. The aim of this study was to assess the incidence and outcomes of this operation by undertaking a retrospective analysis of a large national registry in the UK. METHODS: All acute pulmonary embolectomies performed between 1996 and 2018 were captured in the National Institute of Cardiovascular Outcomes Research central database. Trends in the number of operations performed during this interval and reported in-hospital outcomes were analysed retrospectively. Multivariable logistic regression was used to identify independent risk factors for in-hospital death. RESULTS: All 256 patients treated surgically for acute pulmonary embolism during the study interval were included in the analysis. Median age at presentation was 54 years, 55.9% of the patients were men, 48.0% had class IV heart failure symptoms, and 37.5% had preoperative cardiogenic shock. The median duration of bypass was 73 min, and median cross-clamp time was 19 min. Cardioplegic arrest was used in 53.1% of patients. The median duration of hospital stay was 11 days. The in-hospital mortality rate was 25%, postoperative stroke occurred in 5.4%, postoperative dialysis was required in 16%, and the reoperation rate for bleeding was 7.5%. Risk-adjusted multivariable analysis revealed cardiogenic shock (OR 2.54, 95% c.i. 1.05 to 6.21; P = 0.038), preoperative ventilation (OR 5.85, 2.22 to 16.35; P < 0.001), and duration of cardiopulmonary bypass exceeding 89 min (OR 7.82, 3.25 to 20.42; P < 0.001) as significant independent risk factors for in-hospital death. CONCLUSION: Surgical pulmonary embolectomy is rarely performed in the UK, and is associated with significant mortality and morbidity. Preoperative ventilation, cardiogenic shock, and increased duration of bypass were significant predictors of in-hospital death.


A blood clot in the lung can prevent the lungs from working properly and put pressure on the heart to work harder. Small clots can be treated with medications taken at home and are not a danger to life. Larger blood clots can put a lot of pressure on the heart and need immediate hospital treatment. Large blood clots can be treated with 'clot busting' medications, the delivery of a small tube into the blood vessels of the lung to suck up the clot or deliver medications directly on to its surface, and finally a form of open-heart surgery. With this surgery, a surgeon opens the chest, make a cut into the large vessels containing the clot, and physically removes the large piece of obstructing clot. The aim of this study was to describe and analyse the outcomes of this operation done in the UK over a long period. A database was used to find out how often and where this operation took place and its results. The available data were studied to try to understand how helpful this operation is to patients with lung blood clots. Between 1996 and 2018, 256 people had this operation. One in four patients did not survive the operation, 5.4% developed a clot or bleed in the brain, 16% needed to go on to a dialysis machine, and 7.5% had to be rushed back into theatre because of bleeding. Needing a ventilator machine for help with breathing, being in a sudden state of heart failure, and a long time on the heart bypass machine were all linked with patients who did not survive. This operation is rarely performed in the UK, and is often linked to a high chance of death or serious complication. In this study, the points described above were linked to a bad outcome.


Assuntos
Embolia Pulmonar , Choque Cardiogênico , Masculino , Humanos , Feminino , Estudos Retrospectivos , Choque Cardiogênico/epidemiologia , Choque Cardiogênico/etiologia , Choque Cardiogênico/cirurgia , Resultado do Tratamento , Incidência , Mortalidade Hospitalar , Embolectomia/efeitos adversos , Embolia Pulmonar/epidemiologia , Embolia Pulmonar/cirurgia , Embolia Pulmonar/complicações , Doença Aguda , Reino Unido/epidemiologia
9.
J Cardiothorac Surg ; 19(1): 38, 2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38297304

RESUMO

BACKGROUND: Left ventricular free wall rupture (LVFWR) and interventricular septal rupture (VSR) are potentially catastrophic mechanical complications after acute myocardial infarction (AMI). When they occur together, "double myocardial rupture" (DMR), survival is unlikely. DMR is seen in only 0.3% of all AMIs. With or without surgical intervention, the odds are against the patient. CASE PRESENTATION: A 57-year-old male self-referred to the emergency department of a remote hospital 5 days after first experiencing chest pain. Investigations in ED confirmed an inferior ST-segment elevation myocardial infarction (STEMI) complicated by DMR. Coronary angiography revealed a mid-course total occlusion of the right coronary artery (RCA). He was rapidly transferred to our regional cardiac surgical unit, arriving straight into the operating theatre, in cardiogenic shock. He was briefly conscious, before arresting prior to intubation and being massaged onto bypass. Not only did he survive the all-night operation, requiring a mitral valve replacement in the process, but he survived multiple postoperative complications to be eventually transferred on postoperative day 66, neurologically intact, to a peripheral unit to complete his rehabilitation. He was subsequently discharged home 88 days after the operation and was able to ambulate with a walking frame into his first postoperative follow-up clinic appointment. CONCLUSIONS: Our patient, against all odds, has survived DMR and multiple postoperative complications. We present the details of his case and the literature surrounding the condition. The patient's mental fortitude and his supportive family played a significant role, along with excellent multidisciplinary team work, in assuring his survival.


Assuntos
Ruptura Cardíaca Pós-Infarto , Ruptura Cardíaca , Infarto do Miocárdio , Masculino , Humanos , Pessoa de Meia-Idade , Ruptura Cardíaca Pós-Infarto/cirurgia , Infarto do Miocárdio/cirurgia , Ruptura Cardíaca/cirurgia , Ruptura Cardíaca/complicações , Choque Cardiogênico/etiologia , Choque Cardiogênico/cirurgia , Complicações Pós-Operatórias
10.
Perfusion ; 39(3): 564-570, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36645201

RESUMO

BACKGROUND: Limited data evaluated the outcomes of extracorporeal membrane oxygenation (ECMO) in patients with prosthetic valves. This study aimed to compare the outcomes of ECMO support for postcardiotomy cardiogenic shock in patients with mechanical versus bioprosthetic valves. METHODS: This retrospective study included patients with ECMO support for postcardiotomy cardiogenic shock after valve replacement. Patients were grouped into bioprosthetic (n = 49) and mechanical valve (n = 22) groups. RESULTS: There were no differences in ECMO duration, inotropic support, intra-aortic balloon pump (IABP), stroke, duration of ICU, and hospital stay between groups. Postoperative thrombosis occurred in 2 patients with bioprosthetic valves (5.41%) and 2 with mechanical valves (14.29%), p = .30. All patients with thrombosis had central ECMO cannulation, concomitant IABP, and inotropic support during ECMO. All thrombi were related to the mitral valve. Three patients with thrombi had hospital mortality.Survival at 6, 12, and 36 months for bioprosthetic valve patients was 30.88%, 28.55%, and 25.34% and for mechanical valves was 36.36% for all time intervals (Log-rank p = .93). One patient had bioprosthetic aortic valve endocarditis after 1 year. Three patients with bioprosthetic valves had structural valve degeneration after 1, 2, and 5 years. CONCLUSIONS: Outcomes of ECMO in patients with prosthetic valves are comparable between bioprosthetic and mechanical valves. Thrombosis might occur in both valve types and was associated with high mortality. ECMO could affect the long-term durability of the bioprosthetic valves.


Assuntos
Oxigenação por Membrana Extracorpórea , Acidente Vascular Cerebral , Trombose , Humanos , Choque Cardiogênico/etiologia , Choque Cardiogênico/cirurgia , Oxigenação por Membrana Extracorpórea/efeitos adversos , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia , Trombose/etiologia
13.
ASAIO J ; 70(4): e61-e64, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37913501

RESUMO

Mechanical circulatory support for cardiogenic shock complicated by acute severe aortic regurgitation poses a unique challenge for traditional veno arterial extracorporeal membrane oxygenation (ECMO) because of rapidly rising left ventricular pressures accentuated by the increased afterload from retrograde flow in femoral cannulation. This process necessitates rapid left ventricular unloading while also allowing for adequate native left ventricular function. Herein, we describe a case of cardiogenic and septic shock secondary to methicillin-resistant Staphylococcus aureus complicated by acute severe aortic regurgitation temporized by left atrial-veno arterial (LA-VA) ECMO via the Livanova TandemHeart system. Left ventricular unloading created a window of hemodynamic stability allowing for optimization of multiorgan failure and infectious source control before surgical aortic valve replacement.


Assuntos
Insuficiência da Valva Aórtica , Oxigenação por Membrana Extracorpórea , Staphylococcus aureus Resistente à Meticilina , Humanos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/cirurgia , Choque Cardiogênico/etiologia , Choque Cardiogênico/cirurgia , Átrios do Coração/cirurgia
15.
ASAIO J ; 70(3): 193-198, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37862685

RESUMO

Percutaneous left ventricular assist devices (pVADs) may be used in patients with cardiogenic shock (CS) to stabilize hemodynamics and maintain sufficient end-organ perfusion. Vascular complications are commonly observed in patients with pVAD support. We aimed to assess the relationship between pVAD implantation time and access-site complication rates. This retrospective observational study included all patients who underwent pVAD insertion for the treatment of CS at our university hospital between 2014 and 2021 (n = 224). Depending on the pVAD insertion time, the patients were assigned to the on-hours (n = 120) or off-hours group (n = 104). Both groups had comparable baseline characteristics and comorbidities. The rate of access-site-related complications was higher in the off-hours group than in the on-hours group (26% vs. 10%, p = 0.002). Premature discontinuation of pVAD support to prevent limb ischemia or manage access-site bleeding was required more often in the off-hours group than in the on-hours group (14% vs. 5%, p = 0.016). Pre-existing peripheral artery disease and implantation time off-hours were independent predictors for access-siterelated vascular complications. In conclusion, patients with CS in whom pVAD was inserted during off-hours had higher rates of access-site-related complications and premature discontinuation of pVAD support than those in whom pVAD was inserted during on-hours.


Assuntos
Coração Auxiliar , Procedimentos Cirúrgicos Torácicos , Humanos , Coração Auxiliar/efeitos adversos , Resultado do Tratamento , Choque Cardiogênico/cirurgia , Comorbidade , Estudos Retrospectivos
16.
Int J Cardiol ; 396: 131418, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37813286

RESUMO

INTRODUCTION: Perioperative cardiogenic shock (CS) in cardiac surgery is still burdened by a high mortality risk. The introduction of Impella pumps in the therapeutic armory of temporary mechanical circulatory support (tMCS) has potential implications to improve the management of complex cases, although it has never been systematically addressed. We performed a systematic review of the reported use of tMCS with Impella in cardiac surgery. METHODS: We searched PubMed for all original studies on the Impella use in adult patients in cardiac surgery. RESULTS: Nineteen studies (out of 151 identified by search string) were included. All studies were observational and all but one (95%) were retrospective. Seven studies focused on the implantation of Impella in the pre-operative setting (coronary or valvular surgery), either as a prophylactic device in high-risk cases (3 studies) or in patients with CS as stabilization tool prior to cardiac surgery procedure (4 studies). Three studies reported the use of Impella as periprocedural support for percutaneous valvular procedure, three as bridge to heart replacement, and six for postcardiotomy CS. Impella support had a low complication rate and was successful in supporting hemodynamics pre-, intra- and postoperatively. Most consistently reported data were left-ventricular ejection fraction at implant, short-term survival and weaning rate. CONCLUSIONS: tMCS with Impella in cardiac surgery patients is feasible and successful. It can be applied in selected cardiac surgery patients and presents advantages over other types of support. Systematic prospective studies are needed to standardize indications for implant and management of surgical issues, and to identify which patients may benefit.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Coração Auxiliar , Adulto , Humanos , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Choque Cardiogênico/cirurgia , Choque Cardiogênico/etiologia , Coração Auxiliar/efeitos adversos , Resultado do Tratamento
17.
J Cardiol ; 83(4): 228-235, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37926367

RESUMO

The importance of temporary mechanical circulatory support for treating acute heart failure with cardiogenic shock is increasingly recognized, and Impella (Abiomed, Danvers, MA, USA) has received particular attention in this regard. Impella is an axial flow left ventricular assist device (LVAD) built into the tip of a catheter. It is inserted via a peripheral artery and implanted into the left ventricle. Although the morphology of Impella is different from a typical LVAD, it has similar actions and effects as an LVAD in terms of left ventricular drainage and aortic blood delivery. Impella increases mean arterial pressure (MAP) and systemic blood flow, thereby improving peripheral organ perfusion and promoting recovery from multiple organ failure. In addition, left ventricular unloading with increased MAP increases coronary perfusion and decreases myocardial oxygen demand, thereby promoting myocardial recovery. Impella is also useful as a mechanical vent of the left ventricle in patients supported with veno-arterial extracorporeal membrane oxygenation. Indications for Impella include emergency use for cardiogenic shock and non-emergent use during high-risk percutaneous coronary intervention and ventricular tachycardia ablation. Its intended uses for cardiogenic shock include bridge to recovery, durable device, heart transplantation, and heart surgery. Prophylactic use of Impella in high-risk patients undergoing open heart surgery to prevent postcardiotomy cardiogenic shock is also gaining attention. While there have been many case reports and retrospective studies on the benefits of Impella, there is little evidence based on sufficiently large randomized controlled trials (RCTs). Currently, several RCTs are now ongoing, which are critical to determine when, for whom, and how these devices should be used. In this review, we summarize the principles, physiology, indications, and complications of the Impella support and discuss current issues and future expectations for the device.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência Cardíaca , Coração Auxiliar , Humanos , Choque Cardiogênico/terapia , Choque Cardiogênico/cirurgia , Coração Auxiliar/efeitos adversos , Motivação , Insuficiência Cardíaca/complicações , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
19.
Sci Rep ; 13(1): 21818, 2023 12 09.
Artigo em Inglês | MEDLINE | ID: mdl-38071378

RESUMO

Surgical intervention in the setting of cardiogenic shock (CS) is burdened with high mortality. Due to acute condition, detailed diagnoses and risk assessment is often precluded. Atrial fibrillation (AF) is a risk factor for perioperative complications and worse survival but little is known about AF patients operated in CS. Current analysis aimed to determine prognostic impact of preoperative AF in patients undergoing heart surgery in CS. We analyzed data from the Polish National Registry of Cardiac Surgery (KROK) Procedures. Between 2012 and 2021, 332,109 patients underwent cardiac surgery in 37 centers; 4852 (1.5%) patients presented with CS. Of those 624 (13%) patients had AF history. Cox proportional hazards models were used for computations. Propensity score (nearest neighbor) matching for the comparison of patients with and without AF was performed. Median follow-up was 4.6 years (max.10.0), mean age was 62 (± 15) years and 68% patients were men. Thirty-day mortality was 36% (1728 patients). The origin of CS included acute myocardial infarction (1751 patients, 36%), acute aortic dissection (1075 patients, 22%) and valvular dysfunction (610 patients, 13%). In an unadjusted analysis, patients with underlying AF had almost 20% higher mortality risk (HR 1.19, 95% CIs 1.06-1.34; P = 0.004). Propensity score matching returned 597 pairs with similar baseline characteristics; AF remained a significant prognostic factor for worse survival (HR 1.19, 95% CI 1.00-1.40; P = 0.045). Among patients with CS referred for cardiac surgery, history of AF was a significant risk factor for mortality. Role of concomitant AF ablation and/or left atrial appendage occlusion or more aggressive perioperative circulatory support should be addressed in the future.


Assuntos
Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Infarto do Miocárdio , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Choque Cardiogênico/cirurgia , Choque Cardiogênico/complicações , Prognóstico , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Infarto do Miocárdio/complicações , Fatores de Risco , Resultado do Tratamento
20.
J Cardiothorac Surg ; 18(1): 343, 2023 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-38012790

RESUMO

OBJECTIVES: Cardiogenic shock (CS) can occur in patients with Takotsubo syndrome (TTS). As TTS has received increasing attention and has been more closely researched, several aspects of the pathogenesis have been identified, particularly that an excessive release of catecholamines plays an important role. Nevertheless, evidence on specific therapy concepts is still lacking. As a result, TTS with severe hemodynamic instability and low cardiac output creates unique challenges, and mechanical circulatory support is needed with as few inotropic drugs as possible. METHODS: We present a 77-year-old female patient who underwent minimally invasive surgical mitral valve replacement. After an uneventful course, the patient developed acute heart failure eleven days after surgery. Transthoracic echocardiography (TTE) revealed a new onset of TTS. The patient needed left ventricular venting and full haemodynamic flow. We successfully implanted a microaxial left ventricular assist device (Impella 5.5) using the transaxillary approach. The haemodynamic situation stabilised immediately. The patient was weaned and the Impella 5.5 was explanted after five days. CONCLUSION: We present the first-in-man implantation of a transaxillary Impella 5.5 in a patient with TTS. The patient benefitted from Impella 5.5 therapy with full haemodynamic support and venting of the left ventricle.


Assuntos
Coração Auxiliar , Cardiomiopatia de Takotsubo , Feminino , Humanos , Idoso , Choque Cardiogênico/etiologia , Choque Cardiogênico/cirurgia , Coração Auxiliar/efeitos adversos , Cardiomiopatia de Takotsubo/complicações , Cardiomiopatia de Takotsubo/cirurgia , Resultado do Tratamento , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...