Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.056
Filtrar
1.
Invest Ophthalmol Vis Sci ; 65(5): 14, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38713483

RESUMO

Purpose: The purpose of this study was to assess the impact of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) on corneal stroma characteristics, ocular manifestations, and post-recovery refractive surgery outcomes after varying recovery durations. Methods: Fresh corneal lenticules from patients with post-coronavirus disease 2019 (COVID-19; recovered within 135 days) and healthy controls (HCs) after small incision lenticule extraction (SMILE) surgery were obtained for experimental validation of SARS-CoV-2 susceptibility, morphological changes, and immune response of the corneal stroma. Corneal optical density (CD) was measured using the Pentacam HR. Corneal epithelium thickness (ET) and endothelium parameters were evaluated by wide-field optical coherence tomography (OCT) and non-contact specular microscopy (SP-1P), respectively. All the patients were assessed after SMILE surgery until 3 month of follow-up. Results: The cornea was susceptible to SARS-CoV-2 with the presence of SARS-CoV-2 receptors (CD147 and ACE2) and spike protein remnants (4 out of 58) in post-recovery corneal lenticules. Moreover, SARS-CoV-2 infection triggered immune responses in the corneal stroma, with elevated IL-6 levels observed between 45 and 75 days post-recovery, which were then lower at around day 105. Concurrently, corneal mid-stromal nerve length and branching were initially higher in the 60D to 75D group and returned to control levels by day 135. A similar trend was observed in CD within zones 0 to 2 and 2 to 6 and in the hexagonal cells (HEX) ratio in endothelial cells, whereas ET remained consistent. Notably, these changes did not affect the efficacy, safety, or predictability of post-recovery SMILE surgery. Conclusions: SARS-CoV-2 induces temporal alterations in corneal stromal morphology and function post-recovery. These findings provided a theoretical basis for corneal health and refractive surgery management in the post-COVID-19 milieu.


Assuntos
COVID-19 , Substância Própria , SARS-CoV-2 , Tomografia de Coerência Óptica , Humanos , Substância Própria/patologia , Substância Própria/virologia , Masculino , Feminino , Adulto , Tomografia de Coerência Óptica/métodos , Cirurgia da Córnea a Laser/métodos , Pessoa de Meia-Idade
2.
J Refract Surg ; 40(5): e328-e335, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38717080

RESUMO

PURPOSE: To evaluate moderate to high astigmatism corrections on the outcomes of SmartSight lenticule extraction for myopic astigmatism with a new femtosecond laser system. METHODS: Two hundred ninety-two eyes consecutively treated for myopic astigmatism with astigmatism magnitude greater than 1.00 diopter (D) were evaluated at the 6-month follow-up visit. The mean age of the patients was 29 ± 6 years with a mean spherical equivalent of -5.06 ± 2.20 diopters (D) and a mean magnitude of refractive astigmatism of 1.74 ± 0.61 D. RESULTS: At 6 months, astigmatism was 0.10 ± 0.20 D. Uncorrected and corrected distance visual acuities (UDVA and CDVA, respectively) were both 0.0 ± 0.1 logMAR. Differences between postoperative UDVA and preoperative CDVA and the change in CDVA were both +0.4 ± 0.7 lines better than preoperatively (P < .0003). CONCLUSIONS: Lenticule extraction treatment using Smart-Sight is safe and efficacious at 6 months. Findings suggest that moderate to high astigmatism improves after SmartSight lenticule extraction in the treatment of myopic astigmatism. [J Refract Surg. 2024;40(5):e328-e335.].


Assuntos
Astigmatismo , Substância Própria , Lasers de Excimer , Miopia , Refração Ocular , Acuidade Visual , Humanos , Astigmatismo/fisiopatologia , Astigmatismo/cirurgia , Acuidade Visual/fisiologia , Estudos Retrospectivos , Adulto , Refração Ocular/fisiologia , Masculino , Feminino , Miopia/cirurgia , Miopia/fisiopatologia , Adulto Jovem , Substância Própria/cirurgia , Lasers de Excimer/uso terapêutico , Topografia da Córnea , Seguimentos , Resultado do Tratamento , Cirurgia da Córnea a Laser/métodos
3.
J Refract Surg ; 40(5): e291-e303, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38717083

RESUMO

PURPOSE: To compare differences in corneal densitometry (CD) and higher order aberrations (HOAs) in eyes that underwent small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for the treatment of myopia and myopic astigmatism at postoperative months 3, 6, and 12, and to evaluate their changes in a separate cohort of eyes after SMILE enhancement. METHODS: In this prospective, randomized, paired-eye clinical trial, consecutive eligible participants were randomized to undergo SMILE or FS-LASIK in either eye. Main outcome measures were CD and HOAs preoperatively and at 3, 6, and 12 months postoperatively. A separate cohort of consecutive patients who had SMILE and underwent enhancement were also included for comparison. RESULTS: For CD, no significant differences were found between SMILE and FS-LASIK up to month 12. For HOA measured by wavefront aberrometry, both SMILE and FS-LASIK had an increase in total root mean square (RMS) HOAs, spherical aberration (SA), and vertical coma up to month 12. SMILE had an additional increase in vertical quatrefoil, and FS-LASIK had an increase in horizontal coma at month 12. FS-LASIK had higher SA than SMILE, whereas SMILE had higher vertical quatrefoil than FS-LASIK at month 12. Central and posterior zone CD had significantly decreased after SMILE enhancement compared to after primary SMILE up to 2 years after enhancement. RMS HOAs, lower order aberrations, and SA were all increased after SMILE enhancement compared to after primary SMILE. CONCLUSIONS: SMILE induced lower SA but higher vertical quatrefoil than FS-LASIK at 1 year. Both SMILE and FS-LASIK had similar increases in RMS HOAs and vertical coma up to 1 year. There were no differences in CD between both groups. SMILE enhancement additionally had decreased central and posterior CD but greater RMS HOAs and SA compared to primary SMILE. [J Refract Surg. 2024;40(5):e291-e303.].


Assuntos
Aberrometria , Astigmatismo , Córnea , Substância Própria , Aberrações de Frente de Onda da Córnea , Densitometria , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Miopia , Refração Ocular , Acuidade Visual , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Estudos Prospectivos , Miopia/cirurgia , Miopia/fisiopatologia , Adulto , Feminino , Masculino , Lasers de Excimer/uso terapêutico , Acuidade Visual/fisiologia , Substância Própria/cirurgia , Córnea/cirurgia , Córnea/fisiopatologia , Adulto Jovem , Refração Ocular/fisiologia , Astigmatismo/cirurgia , Astigmatismo/fisiopatologia , Cirurgia da Córnea a Laser/métodos , Topografia da Córnea
4.
J Refract Surg ; 40(5): e321-e327, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38717082

RESUMO

PURPOSE: To evaluate the characteristic of corrective epithelial thickness after femtosecond laser-assisted lenticule intrastromal keratoplasty (LIKE) to correct moderate-to-high hyperopia. METHODS: The prospective case series study of the LIKE procedure was performed to correct moderate-to-high hyperopia. The epithelial thickness map was generated by anterior segment optical coherence tomography (AS-OCT) in the corneal central 9-mm zone. Keratometry and corneal higher order aberrations were analyzed by Pentacam (Oculus Optikgeräte GmbH) preoperatively and postoperatively. RESULTS: In the 26 eyes of 13 participants who underwent the LIKE procedure for moderate-to-high hyperopia, the attempted spherical equivalence (SEQ) was +6.50 ± 1.09 diopters (D). Compared to the preoperative epithelial thickness maps, the postoperative epithelial thickness had become significantly thinner in the central 5-mm zone; the difference was 6 to 7 µm. The paracentral epithelium performed nonuniform remodeling; the thinnest epithelial thickness was located in the inferotemporal section, which has the greatest difference from the superonasal; the difference between these two was approximately 3 µm. Through correlation analysis, it was found that the sections with thinner epithelium were significantly related to corneal curvature and corneal vertical coma. CONCLUSIONS: The LIKE procedure can be used to correct moderate-to-high hyperopia. This study further indicated the epithelial remodeling characteristic after the LIKE procedure: the central and paracentral corneal epithelial thickness becomes thinner, and the epithelial thickness distributes non-uniformly, which may be the important factor of the postoperative curvature asymmetric distribution and induction of corneal vertical coma. [J Refract Surg. 2024;40(5):e321-e327.].


Assuntos
Substância Própria , Topografia da Córnea , Epitélio Corneano , Hiperopia , Refração Ocular , Tomografia de Coerência Óptica , Acuidade Visual , Humanos , Hiperopia/cirurgia , Hiperopia/fisiopatologia , Estudos Prospectivos , Substância Própria/cirurgia , Substância Própria/patologia , Masculino , Feminino , Adulto , Acuidade Visual/fisiologia , Epitélio Corneano/cirurgia , Epitélio Corneano/patologia , Refração Ocular/fisiologia , Pessoa de Meia-Idade , Lasers de Excimer/uso terapêutico , Adulto Jovem , Aberrações de Frente de Onda da Córnea/fisiopatologia , Cirurgia da Córnea a Laser/métodos , Oftalmopatias Hereditárias
5.
J Refract Surg ; 40(5): e344-e352, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38717086

RESUMO

PURPOSE: To compare the effects of three common refractive surgeries on corneal biomechanics. METHODS: Two hundred seven patients who had refractive surgery were included in this study, of whom 65 received transepithelial photorefractive keratectomy (tPRK), 73 received femtosecond laser-assisted laser in situ keratomileusis (FSLASIK), and 69 received small incision lenticule extraction (SMILE). Each patient had biomechanical measurements using the Corvis ST (Oculus Optikgeräte GmbH) preoperatively and at 3 and 6 months postoperatively. The measurements included five parameters expected to be associated with corneal biomechanics: deformation amplitude ratio at 2 mm (DAR2), integrated inverse radius (IIR), stiffness parameter at first applanation (SP-A1), highest concavity time (HCT), and the updated stress-strain index (SSIv2). The variations in these parameters postoperatively among the three surgeries, and their relationship with corneal thickness (CCT) and intraocular pressure measured by the Dynamic Contour Tonometer (DCT-IOP) were analyzed. RESULTS: SP-A1 decreased significantly from preoperatively to 3 months postoperatively in all three groups, whereas DAR2 and IIR increased significantly, all indicating stiffness losses. Between 3 and 6 months postoperatively, the results were inconsistent, with DAR2 decreasing (indicating stiffness increases) and IIR increasing (denoting stiffness decreases) in the FS-LASIK and SMILE groups. The decrease in SSIv2 (the only measure of corneal material stiffness) postoperatively was comparatively less pronounced at both 3 and 6 months postoperatively. On the other hand, HCT remained generally stable after all three surgeries. Unlike DAR2, IIR, and SP-A1, the changes postoperatively in stiffness parameters HCT and SSIv2 were independent of the corresponding changes in both DCT-IOP and CCT. CONCLUSIONS: Among the stiffness parameters considered, SSIv2 was not correlated with CCT or DCT-IOP, and holds promise for representing the corneal material stiffness and how it remains largely unaffected by refractive surgeries. Overall, FS-LASIK had the most significant impact on corneal stiffness, followed by SMILE, and finally tPRK. [J Refract Surg. 2024;40(5):e344-e352.].


Assuntos
Córnea , Elasticidade , Pressão Intraocular , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Miopia , Humanos , Córnea/fisiopatologia , Córnea/cirurgia , Adulto , Feminino , Masculino , Fenômenos Biomecânicos , Lasers de Excimer/uso terapêutico , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Adulto Jovem , Elasticidade/fisiologia , Miopia/cirurgia , Miopia/fisiopatologia , Pressão Intraocular/fisiologia , Ceratectomia Fotorrefrativa/métodos , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Pessoa de Meia-Idade , Estudos Prospectivos , Cirurgia da Córnea a Laser/métodos , Topografia da Córnea
6.
BMC Ophthalmol ; 24(1): 211, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38741093

RESUMO

OBJECTIVE: To investigate the correlation between higher-order aberrations (HOA) after small incision lenticule extraction (SMILE) and the severity of myopia and astigmatism, along with the relevant factors. These findings will provide valuable insights for decreasing the occurrence of HOA after SMILE and enhancing visual quality. METHODS: A total of 75 patients (150 eyes) with myopia and astigmatism who underwent SMILE were categorized into four groups based on the severity of myopia and astigmatism: Myopia Group 1 (Group M1, spherical diopter ranged from -1.00 D to -4.00 D), Myopia Group 2 (Group M2, spherical diopter ranged from -4.10 D to -10.00 D), Astigmatism Group 1 (Group A1, cylindrical diopter ranged from 0 D to -1.00 D), and Astigmatism Group 2 (Group A2, cylindrical diopter ranged from -1.10 D to -3.00 D). A comprehensive assessment was performed to examine the association between HOA and various relevant factors, including a detailed analysis of the subgroups. RESULTS: Group M1 had significantly lower levels of total eye coma aberration (CA), corneal total HOA (tHOA), internal tHOA, and vertical CA ( Z 3 - 1 ) after SMILE than Group M2 (P < 0.05). Similarly, Group A1 had significantly lower levels of total eye tHOA, CA, trefoil aberration (TA), corneal tHOA, TA, and vertical TA ( Z 3 - 3 ) after SMILE than Group A2 (P < 0.05). Pearson correlation analysis indicated a statistically significant positive relationship between the severity of myopia/astigmatism and most HOA (P < 0.05). Subgroup evaluations demonstrated a notable increase in postoperative HOA associated with myopia and astigmatism in Groups M2 and A2 compared with the control group. Lenticule thickness, postoperative central corneal thickness (CCT), postoperative uncorrected distance visual acuity (UDVA), and postoperative corneal Km and Cyl were strongly correlated with most HOA. Age, eyes, and postoperative intraocular pressure (IOP) were only associated with specific HOA. CONCLUSION: HOA positively correlated with the severity of myopia and astigmatism after SMILE. However, this relationship was not linear. HOA after SMILE was influenced by various factors, and additional specialized investigations are required to establish its clinical importance.


Assuntos
Astigmatismo , Cirurgia da Córnea a Laser , Aberrações de Frente de Onda da Córnea , Miopia , Refração Ocular , Acuidade Visual , Humanos , Miopia/cirurgia , Miopia/fisiopatologia , Astigmatismo/fisiopatologia , Astigmatismo/etiologia , Masculino , Feminino , Adulto , Acuidade Visual/fisiologia , Cirurgia da Córnea a Laser/métodos , Cirurgia da Córnea a Laser/efeitos adversos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/etiologia , Adulto Jovem , Refração Ocular/fisiologia , Substância Própria/cirurgia , Estudos Retrospectivos , Lasers de Excimer/uso terapêutico , Complicações Pós-Operatórias , Topografia da Córnea , Adolescente
7.
Vestn Oftalmol ; 140(2): 85-90, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38742503

RESUMO

The introduction of early diagnostic methods for keratoconus into clinical practice has become the basis for the development of surgical treatment techniques for this pathology, such as corneal collagen crosslinking and interlamellar keratoplasty with implantation of intrastromal segments. The article analyzes the results of research by Russian and foreign specialists in these areas and presents the data on the combination of SMILE surgery and corneal crosslinking, the Rome protocol of corneal crosslinking, modifications of interlamellar keratoplasty, the use of femtosecond laser technologies, and some pilot studies. Modern requirements for ophthalmological care require a personalized approach to each patient, and therefore the surgeon should have a wide range of surgical methods of treatment applicable to different patient cohorts. The described methods of treatment, according to the authors, are the most promising.


Assuntos
Ceratocone , Ceratocone/cirurgia , Ceratocone/diagnóstico , Humanos , Córnea/cirurgia , Córnea/diagnóstico por imagem , Transplante de Córnea/métodos , Cirurgia da Córnea a Laser/métodos , Resultado do Tratamento , Colágeno
8.
Sci Rep ; 14(1): 8732, 2024 04 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627567

RESUMO

We sought to evaluate the topographic risk factors for early myopic regression after small-incision lenticule extraction (SMILE). A retrospective case‒control study was conducted, and individuals who underwent SMILE surgery were enrolled. Among them, 406 and 14 eyes were categorized into the nonregression and regression groups, respectively. The preoperative and postoperative parameters in the two groups were collected, including spherical refraction (SE), axial length (AXL) and topographic data. A generalized linear model was adopted to analyze the difference in each parameter between the two groups. After 6 months, UCVA decreased in the regression group, and SE increased in the regression group (both P < 0.05). The increase in the CCT at the thinnest point (P = 0.044), flat corneal curvature (P = 0.012) and TCRP (P = 0.001) were significantly greater in the regression group. Regarding the risk factors for myopic regression, preoperative SE, preoperative sphere power, preoperative AXL, preoperative flat corneal curvature, preoperative SA, early postoperative SE, early postoperative sphere power, early postoperative AXL and early postoperative CCT difference were significantly greater in the regression group (all P < 0.05). The SE, sphere power, AXL, preoperative flat corneal curvature, preoperative SA, and postoperative CCT difference correlate with early myopic regression after SMILE.


Assuntos
Cirurgia da Córnea a Laser , Miopia , Ferida Cirúrgica , Humanos , Córnea/cirurgia , Substância Própria/cirurgia , Acuidade Visual , Estudos Retrospectivos , Estudos de Casos e Controles , Cirurgia da Córnea a Laser/efeitos adversos , Lasers de Excimer/uso terapêutico , Refração Ocular , Miopia/cirurgia , Ferida Cirúrgica/cirurgia
9.
Zhonghua Yan Ke Za Zhi ; 60(3): 275-277, 2024 Mar 11.
Artigo em Chinês | MEDLINE | ID: mdl-38462377

RESUMO

A 31-year-old female patient with refractive error in both eyes underwent small incision lenticule extraction. On the 4th day after surgery, arc-shaped peripheral corneal infiltrates appeared in the right eye. Tobramycin and dexamethasone eye drops, 0.3% gatifloxacin eye drops, and a corneal bandage lens were applied to the eye. After bacterial infection was ruled out, dexamethasone sodium phosphate was injected subconjunctivally near the corneal lesion. The symptoms improved and the corneal lesion subsided afterwards.


Assuntos
Doenças da Córnea , Cirurgia da Córnea a Laser , Miopia , Feminino , Humanos , Adulto , Substância Própria/cirurgia , Acuidade Visual , Miopia/cirurgia , Córnea/cirurgia , Cirurgia da Córnea a Laser/efeitos adversos , Doenças da Córnea/cirurgia , Soluções Oftálmicas , Topografia da Córnea , Refração Ocular , Lasers de Excimer
10.
BMC Ophthalmol ; 24(1): 117, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38481187

RESUMO

BACKGROUND: To report a case of interface fluid syndrome (IFS) following traumatic corneal perforation repair after small incision lenticule extraction (SMILE). CASE PRESENTATION: A 23-year-old woman, with a past history of SMILE, was struck in the left eye with a barbecue prod and subsequently underwent corneal perforation repair at local hospital. Primary wound repaired with a single 10 - 0 nylon suture at the area of leakage. After the surgery, her best corrected visual acuity (BCVA) was 20/30. Four days later, she presented at our hospital with blurred vision, and interface fluid syndrome (IFS) was diagnosed. Intraoperative optical coherence tomography (iOCT) was used to guide the resuturing of the corneal perforation in the left eye, followed by anterior chamber gas injection. At the first postoperative month, the BCVA was 20/25. The corneal cap adhered closely to the stroma, the surface became smooth. CONCLUSIONS: This case illustrates that any corneal perforation following lamellar surgery, including SMILE, may lead to IFS. It is crucial to consider the depth of corneal perforation, and intraoperative optical coherence tomography (iOCT) plays a unique role in the repair procedure.


Assuntos
Perfuração da Córnea , Cirurgia da Córnea a Laser , Miopia , Humanos , Feminino , Adulto Jovem , Adulto , Perfuração da Córnea/diagnóstico , Perfuração da Córnea/etiologia , Perfuração da Córnea/cirurgia , Miopia/cirurgia , Miopia/diagnóstico , Substância Própria/cirurgia , Procedimentos Cirúrgicos Oftalmológicos , Córnea , Tomografia de Coerência Óptica/métodos , Cirurgia da Córnea a Laser/efeitos adversos , Cirurgia da Córnea a Laser/métodos , Topografia da Córnea , Lasers de Excimer
11.
Int Ophthalmol ; 44(1): 153, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38509410

RESUMO

PURPOSE: This study aimed to measure the Raman spectrum of the human corneal stroma lens obtained from small incision lenticule extraction surgery (SMILE) in Asian myopic eyes using a confocal Raman micro-spectrometer built in the laboratory. METHODS: Forty-three myopic patients who underwent SMILE with equivalent diopters between - 4.00 and - 6.00 D were selected, and the right eye data were collected. Corneal stroma lenses were obtained during surgery, and the Raman spectra were measured after air drying. The complete Raman spectrum of human myopic corneal stroma lens tissue was obtained within the range of 700-4000 cm-1. RESULTS: Thirteen characteristic peaks were found, with the stronger peaks appearing at 937 cm-1, corresponding to proline, valine, and the protein skeleton of the human myopic corneal stroma lens; 1243 cm-1, corresponding to collagen protein; 1448 cm-1, corresponding to the collagen protein and phospholipids; and 2940 cm-1, corresponding to the amino acid and lipids, which was the strongest Raman peak. CONCLUSION: These results demonstrated that Raman spectroscopy has much potential as a fast, cost-effective, and reliable diagnostic tool in the diagnosis and treatment of eye diseases, including myopia, keratoconus, and corneal infection.


Assuntos
Cirurgia da Córnea a Laser , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Humanos , Substância Própria/cirurgia , Acuidade Visual , Miopia/diagnóstico , Miopia/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Colágeno , Lasers de Excimer , Refração Ocular
12.
Int Ophthalmol ; 44(1): 52, 2024 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-38340212

RESUMO

PURPOSE: To evaluate the initial visual outcomes of Small Incision Lenticule Extraction (SMILE) Pro® using a 2 MHz femtosecond laser (VisuMax 800, Carl Zeiss Meditec) and to assess the efficacy, safety, predictability, accuracy, and complication rate. METHODS: This retrospective analysis included eyes which underwent the SMILE Pro® procedure using VisuMax 800 femtosecond laser to correct myopia. All surgeries were performed by one surgeon (DB). Follow-up was conducted 3 months postoperatively to evaluate visual outcomes after neuroadaptation, corrected visual acuity (CDVA) and intra- and postoperative complications. RESULTS: One hundred and fifty-two eyes of 82 patients (mean age 31 ± 6 years) results at 3 months are presented. The mean spherical equivalent (SE) was - 4.44 ± 1.86 D preoperatively while -0.24 ± 0.32 D postoperatively. 99% of eyes achieved SE within ± 1.0 D of attempted correction and 91% were within ± 0.5 D. Efficacy index was 0.93 while the safety index was 1. No complications occurred intra- or postoperatively. No eyes lost more than 1 line of their preoperative CDVA. All highly myopic eyes (- 6.25 to - 10.00 D; n = 18) achieved 20/20 at 3 months postoperatively and were within 0.5 D from the attempted SE and no eyes lost more than 1 line of CDVA. CONCLUSION: The SMILE Pro® is a safe, efficient, and predictable procedure for the treatment of myopia and myopic astigmatism, with comparable results of conventional SMILE surgery. High myopic eyes achieve better results than low and moderate myopia. No complications were recorded in our patients.


Assuntos
Astigmatismo , Cirurgia da Córnea a Laser , Miopia , Humanos , Adulto , Acuidade Visual , Estudos Retrospectivos , Refração Ocular , Córnea/cirurgia , Substância Própria/cirurgia , Miopia/cirurgia , Astigmatismo/cirurgia , Lasers , Resultado do Tratamento , Lasers de Excimer/uso terapêutico
13.
J Cataract Refract Surg ; 50(6): 558-564, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38270250

RESUMO

PURPOSE: To determine the clinical outcomes of keratorefractive lenticule extraction (KLEx) in eyes with epithelial basement membrane dystrophy (EBMD) that developed after surgery. SETTING: Onnuri Smile Eye Clinic, Seoul, South Korea. DESIGN: Retrospective single-center study. METHODS: This study reviewed the medical records of 26 eyes of 16 patients who exhibited signs of EBMD after KLEx. Postoperatively, corneal findings and visual outcomes were evaluated. Statistical analyses were also performed on eyes without corneal complications after KLEx. RESULTS: Signs of EBMD were first observed within 1 week postoperatively in 22 eyes (84.6%): 6 eyes (23.1%) showed epithelial defects, 10 eyes (38.5%) showed subepithelial corneal opacity, 5 eyes (19.2%) showed diffuse lamellar keratitis, and 1 eye (3.9%) showed epithelial ingrowth. Symptoms such as pain, while corneal lesions were present, occurred in 21 eyes (80.8%). At 3 months postoperatively, 21 eyes (80.8%) showed no specific findings on slitlamp microscopy after medical treatment, 2 eyes (7.7%) showed subepithelial corneal opacity, 2 eyes (7.7%) showed corneal scar, and 1 eye (3.9%) showed epithelial ingrowth. Uncorrected distance visual acuity was 20/25 or better in 24 eyes (92.3%), and spherical equivalent was within ±1.0 D in 20 eyes (76.9%). The efficacy index of the EBMD group did not significantly differ from the control group, while the safety index was significantly lower. CONCLUSIONS: Manifestations of EBMD can occur after KLEx and can affect clinical outcomes. Most cases showed favorable results with appropriate nonsurgical treatment; however, some cases had long-term complications such as corneal scarring.


Assuntos
Distrofias Hereditárias da Córnea , Cirurgia da Córnea a Laser , Acuidade Visual , Humanos , Estudos Retrospectivos , Acuidade Visual/fisiologia , Masculino , Feminino , Adulto , Distrofias Hereditárias da Córnea/cirurgia , Distrofias Hereditárias da Córnea/fisiopatologia , Cirurgia da Córnea a Laser/métodos , Cirurgia da Córnea a Laser/efeitos adversos , Adulto Jovem , Membrana Basal/cirurgia , Epitélio Corneano/patologia , Complicações Pós-Operatórias , Pessoa de Meia-Idade , Substância Própria/cirurgia , Substância Própria/patologia , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Miopia/fisiopatologia , Topografia da Córnea , Adolescente , Síndrome de Cogan
14.
J Cataract Refract Surg ; 50(5): 523-533, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38288954

RESUMO

Corneal crosslinking (CXL) is used for treating keratoconus and post-laser in situ keratomileusis ectasia. However, refractive surgery is not usually performed with prophylactic CXL. Therefore, we performed a meta-analysis comparing outcomes of refractive surgeries with vs without prophylactic CXL. We systematically searched databases for studies comparing refractive surgeries for myopic correction with vs without prophylactic corneal crosslinking. Review Manager 5.4.1 was used to perform statistical analysis. We included 2820 eyes from 28 studies. Compared with refractive surgery alone, surgery with prophylactic CXL resulted in decreased central corneal thickness, corrected distance visual acuity logMAR, and safety and efficacy indices. There were no significant differences in postoperative uncorrected distance visual acuity of 20/20 or better at ≥12 months and other visual outcomes among both groups. More randomized controlled trials with standard crosslinking protocols are needed to analyze the prophylactic use of crosslinking with refractive surgeries.


Assuntos
Colágeno , Reagentes de Ligações Cruzadas , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Ceratectomia Fotorrefrativa , Fármacos Fotossensibilizantes , Riboflavina , Acuidade Visual , Humanos , Reagentes de Ligações Cruzadas/uso terapêutico , Fármacos Fotossensibilizantes/uso terapêutico , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Riboflavina/uso terapêutico , Colágeno/metabolismo , Acuidade Visual/fisiologia , Miopia/cirurgia , Miopia/fisiopatologia , Ceratectomia Fotorrefrativa/métodos , Fotoquimioterapia/métodos , Lasers de Excimer/uso terapêutico , Substância Própria/metabolismo , Substância Própria/cirurgia , Raios Ultravioleta , Ceratocone/fisiopatologia , Ceratocone/metabolismo , Ceratocone/cirurgia , Ceratocone/tratamento farmacológico , Cirurgia da Córnea a Laser/métodos , Refração Ocular/fisiologia
15.
BMC Ophthalmol ; 24(1): 45, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38287289

RESUMO

BACKGROUND: To evaluate the possible topographic and surgical risk factors for high postoperative residual astigmatism in patients who undergo small-incision lenticule extraction (SMILE) surgery and have different myopia degrees. METHODS: A retrospective cohort study was conducted, and patients who underwent SMILE surgery were enrolled. A total of 80 and 150 eyes from 40 to 75 individuals, respectively, were selected as the low myopia and high myopia groups. The demographic data, visual acuity, refraction, topographic parameters and surgical settings were recorded. Multiple linear regression with interaction tests were performed to survey the risk factors for high postoperative residual astigmatism in each group. RESULTS: Five (6.25%) and 9 (6.00%) eyes presented with high postoperative residual astigmatism in the low myopia and high myopia groups, respectively, but these differences were not significant (P = 0.569). A steep corneal curvature was correlated with a greater risk of high postoperative residual astigmatism in the low myopia group (P = 0.015), while a higher degree of cycloplegic cylinder power, steeper corneal curvature, greater topographic cylinder power, smaller optic zone and longer incision length were associated with a high rate of postoperative residual astigmatism in the high myopia group (all P < 0.05). In addition, the interaction effects of cycloplegic and topographic cylinder power and longer incision length on the incidence of high postoperative residual astigmatism development were more evident in the high myopia group than in the low myopia group (all P < 0.05). CONCLUSIONS: A steep corneal curvature correlates with a high risk of high postoperative residual astigmatism after SMILE surgery, and a higher degree of cycloplegic and topographic cylinder and longer incision are associated with high postoperative residual astigmatism in individuals with high myopia.


Assuntos
Astigmatismo , Cirurgia da Córnea a Laser , Miopia , Humanos , Astigmatismo/etiologia , Astigmatismo/cirurgia , Estudos Retrospectivos , Midriáticos , Topografia da Córnea , Microcirurgia , Refração Ocular , Miopia/cirurgia , Córnea/cirurgia , Substância Própria/cirurgia , Lasers de Excimer/uso terapêutico
16.
Clin Exp Optom ; 107(3): 285-290, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37194118

RESUMO

CLINICAL RELEVANCE: More than 6 million small-incision lenticule extraction (SMILE) procedures have been performed worldwide since 2011. Therefore, its long-term safety and efficacy should be investigated. BACKGROUND: This study aimed to evaluate 10-year refractive outcomes, corneal stability, axial length, and wavefront aberrations in patients who underwent SMILE to correct myopia. METHODS: Thirty two patients (32 eyes) who underwent SMILE-based myopic correction. Corrected distance visual acuity, uncorrected distance visual acuity, corneal stability, axial length, and wavefront aberrations were evaluated preoperatively and at 1 month and 1, 5, and 10 years postoperatively. RESULTS: At 10 years postoperatively, the safety and efficacy indices for the patients included in this study were 1.19 ± 0.21 and 1.04 ± 0.27, respectively. For 26 (81%) and 30 eyes (94%), correction to within ±0.50 D and ±1.00 D of the target was achieved, respectively. Over the 10-year follow-up duration, a mean -0.32 ± 0.56 D regression was observed (-0.03 ± 0.06 D/year). Relative to baseline, horizontal and vertical comas significantly increased, as did the incidence of higher-order aberrations (all P < 0.001), whereas axial length and corneal elevation remained stable during follow-up. CONCLUSION: These results indicate that the SMILE-based correction for myopia of up to -10 Dioptres is safe, effective, and stable, with relatively constant wavefront aberrations and corneal stability over time after treatment.


Assuntos
Astigmatismo , Cirurgia da Córnea a Laser , Miopia , Humanos , Lasers de Excimer/uso terapêutico , Acuidade Visual , Refração Ocular , Miopia/cirurgia , Córnea/cirurgia , Substância Própria/cirurgia , Resultado do Tratamento , Cirurgia da Córnea a Laser/métodos , Astigmatismo/cirurgia
17.
Graefes Arch Clin Exp Ophthalmol ; 262(1): 313-321, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37405512

RESUMO

PURPOSE: To investigate changes in disk halo size after small incision lenticule extraction (SMILE) and the correlation between halo size and lenticule quality in moderate to high myopia. METHODS: Thirty eyes of 30 consecutive patients (mean age, 24.9 ± 4.5 years; mean spherical equivalent, -6.85 ± 1.18 D) undergoing SMILE were included in this prospective study. Lenticule surface quality was accessed with a scanning electron microscopy by a scoring system. Halo size was measured preoperatively and at 1, 3, and 6 months postoperatively. Multiple linear regression analysis was performed to explore associations between halo size and a range of factors, including lenticule quality. RESULTS: Disk halo size increased slightly at 1 month and then recovered continually from 3 to 6 months postoperatively, with no difference between halo size during the preoperative period and at 6 months postoperatively (P > 0.05). One month after SMILE, halo size (1 cd/m2, 5 cd/m2) was associated only with uncorrected distance visual acuity (P ≤ 0.004). A halo size of 5 cd/m2 at 3 months postoperatively correlated with the anterior surface quality of the lenticule (P = 0.046). At 6 months postoperatively, a halo size of 1 cd/m2 was associated only with the baseline, accounting for 11.9% of the variability (P = 0.041); no correlations were found for the halo size of 5 cd/m2. CONCLUSIONS: Disk halo size after SMILE was enlarged at an early stage postoperatively and subsequently declined to the baseline level during a 6-month follow-up. The quality of the lenticule surface influenced halo size changes in the early phase.


Assuntos
Cirurgia da Córnea a Laser , Miopia , Humanos , Adulto Jovem , Adulto , Substância Própria/cirurgia , Estudos Prospectivos , Miopia/diagnóstico , Miopia/cirurgia , Acuidade Visual , Refração Ocular , Lasers de Excimer/uso terapêutico , Resultado do Tratamento
18.
Cornea ; 43(2): 154-158, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37186807

RESUMO

PURPOSE: To investigate the visual, refractive, and biomechanical outcomes of small incision lenticule extraction (SMILE) with two different cap thicknesses. METHODS: Thirty-four patients were included in this prospective, randomized, contralateral eye study. Subjects were randomized to receive SMILE surgery with a 110-m cap thickness in one eye and 145-µm cap thickness in the fellow eye. Uncorrected and corrected distance visual acuity, contrast sensitivity (CS), total higherorder aberrations (THOAs) and corneal biomechanical properties were compared 3 months after surgery. RESULTS: Postoperative refractive and visual outcomes, CS and THOAs were similar between the two groups ( P > 0.05 for all parameters). At 3 months postoperatively, there was a significant difference in Corvis ST Biomechanical Index (CBI); stiffness parameter at first applanation (SP A1), and Integrated Radius between the two groups (all P < 0.05). CONCLUSIONS: Eyes with thicker SMILE corneal caps showed no advantage regarding visual acuity, CS and THOAs over eyes with thinner caps. However, higher cap thickness may result in better corneal biomechanical properties postoperatively.


Assuntos
Cirurgia da Córnea a Laser , Miopia , Humanos , Substância Própria/cirurgia , Estudos Prospectivos , Miopia/cirurgia , Córnea/cirurgia , Acuidade Visual , Refração Ocular , Lasers de Excimer/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...