1.
Biomolecules ; 14(5)2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38785994

RESUMO

BACKGROUND: Fluorescent proteins (FPs) are pivotal reagents for flow cytometry analysis or fluorescent microscopy. A new generation of immunoreagents (fluobodies/chromobodies) has been developed by fusing recombinant nanobodies to FPs. METHODS: We analyzed the quality of such biomolecules by a combination of gel filtration and SDS-PAGE to identify artefacts due to aggregation or material degradation. RESULTS: In the SDS-PAGE run, unexpected bands corresponding to separate fluobodies were evidenced and characterized as either degradation products or artefacts that systematically resulted in the presence of specific FPs and some experimental conditions. The elimination of N-terminal methionine from FPs did not impair the appearance of FP fragments, whereas the stability and migration characteristics of some FP constructs were strongly affected by heating in loading buffer, which is a step samples undergo before electrophoretic separation. CONCLUSIONS: In this work, we provide explanations for some odd results observed during the quality control of fluobodies and summarize practical suggestions for the choice of the most convenient FPs to fuse to antibody fragments.


Assuntos
Eletroforese em Gel de Poliacrilamida , Eletroforese em Gel de Poliacrilamida/métodos , Anticorpos de Domínio Único/química , Humanos , Cromatografia em Gel , Citometria de Fluxo/normas , Citometria de Fluxo/métodos , Controle de Qualidade
2.
World J Microbiol Biotechnol ; 40(7): 222, 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38811387

RESUMO

In this study, it was aimed to investigate bacterial contamination in apheresis platelet suspensions (APS) by automated blood culture system and flow cytometry method (FCM).33 spiked APS each using 11 bacterial strains (5 standard strains, 6 clinical isolates), were prepared in three different dilutions (1-10, 10-50, 50-100 cfu/mL), incubated in two different temperatures (35-37 °C and 22-24 °C) and different incubation times (18-96 h) evaluated by FCM. This three different dilutions were also inoculated into special platelet culture bottles (BacT/ALERT® BPA) and loaded into the blood culture system. Additionally 80 APSs routinely prepared in the Transfusion Center were evaluated by both FCM and the blood culture system. Platelets were lysed by freeze-thaw method.All spiked samples were positive with BacT/ALERT® BPA in 12-18 h. In 96 h incubation at 22-24 °C, the presence of bacteria was detected by FCM in all other samples (31/33) except low dilutions (1-10 and 10-100 CFU/ml) of K.pneumoniae standard strain. In the 35-37 °C, the presence of bacteria was detected by FCM in all samples (33/33) after 48 h of incubation. In routine APS one sample detected as positive (Bacillus simplex) with BacT/ALERT® BPA and no positivity was detected by FCM.The freeze-thaw method, which we have optimized for the lysis of platelets, is very practical and can be easily applied. The BacT/ALERT® system has been found to be very sensitive in detecting bacterial contamination in PSs. Flow cytometry method has been found to be successful, fast, easy to use and low cost in detecting bacterial contamination in PSs.


Assuntos
Plaquetas , Segurança do Sangue , Citometria de Fluxo , Segurança do Sangue/instrumentação , Segurança do Sangue/métodos , Plaquetas/microbiologia , Citometria de Fluxo/normas , Remoção de Componentes Sanguíneos , Hemocultura/normas , Bactérias/isolamento & purificação , Humanos , Sensibilidade e Especificidade
3.
Cytometry B Clin Cytom ; 106(3): 192-202, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38700195

RESUMO

The assessment of T-cell clonality by flow cytometry has long been suboptimal, relying on aberrant marker expression and/or intensity. The introduction of TRBC1 shows much promise for improving the diagnosis of T-cell neoplasms in the clinical flow laboratory. Most laboratories considering this marker already have existing panels designed for T-cell workups and will be determining how best to incorporate TRBC1. We present this comprehensive summary of TRBC1 and supplemental case examples to familiarize the flow cytometry community with its potential for routine application, provide examples of how to incorporate it into T-cell panels, and signal caution in interpreting the results in certain diagnostic scenarios where appropriate.


Assuntos
Citometria de Fluxo , Linfócitos T , Citometria de Fluxo/métodos , Citometria de Fluxo/normas , Humanos , Linfócitos T/imunologia , Imunofenotipagem/métodos , Biomarcadores Tumorais/imunologia , Biomarcadores Tumorais/genética
4.
Methods Cell Biol ; 186: 107-130, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38705596

RESUMO

Mass cytometry permits the high dimensional analysis of cellular systems at single-cell resolution with high throughput in various areas of biomedical research. Here, we provide a state-of-the-art protocol for the analysis of human peripheral blood mononuclear cells (PBMC) by mass cytometry. We focus on the implementation of measures promoting the harmonization of large and complex studies to aid robustness and reproducibility of immune phenotyping data.


Assuntos
Citometria de Fluxo , Leucócitos Mononucleares , Humanos , Leucócitos Mononucleares/citologia , Leucócitos Mononucleares/imunologia , Citometria de Fluxo/métodos , Citometria de Fluxo/normas , Imunofenotipagem/métodos , Análise de Célula Única/métodos
5.
Cytometry B Clin Cytom ; 106(3): 203-215, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38656036

RESUMO

The monocyte subset partitioning by flow cytometry, known as "monocyte assay," is now integrated into the new classifications as a supporting criterion for CMML diagnosis, if a relative accumulation of classical monocytes above 94% of total circulating monocytes is observed. Here we provide clinical flow cytometry laboratories with technical support adapted for the most commonly used cytometers. Step-by-step explanations of the gating strategy developed on whole peripheral blood are presented while underlining the most common difficulties. In a second part, interpretation recommendations of circulating monocyte partitioning from the dedicated French working group "CytHem-LMMC" are shared as well as the main pitfalls, including false positive and false negative cases. The particular flow-defined inflammatory profile is described and the usefulness of the nonclassical monocyte specific marker, namely slan, highlighted. Examples of reporting to the physician with frequent situations encountered when using the monocyte assay are also presented.


Assuntos
Citometria de Fluxo , Monócitos , Citometria de Fluxo/métodos , Citometria de Fluxo/normas , Humanos , Monócitos/citologia , Monócitos/imunologia , Imunofenotipagem/métodos , Imunofenotipagem/normas
7.
Clin Chem Lab Med ; 62(7): 1411-1420, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38217085

RESUMO

OBJECTIVES: Lymphocyte subsets are the predictors of disease diagnosis, treatment, and prognosis. Determination of lymphocyte subsets is usually carried out by flow cytometry. Despite recent advances in flow cytometry analysis, most flow cytometry data can be challenging with manual gating, which is labor-intensive, time-consuming, and error-prone. This study aimed to develop an automated method to identify lymphocyte subsets. METHODS: We propose a knowledge-driven combined with data-driven method which can gate automatically to achieve subset identification. To improve accuracy and stability, we have implemented a Loop Adjustment Gating to optimize the gating result of the lymphocyte population. Furthermore, we have incorporated an anomaly detection mechanism to issue warnings for samples that might not have been successfully analyzed, ensuring the quality of the results. RESULTS: The evaluation showed a 99.2 % correlation between our method results and manual analysis with a dataset of 2,000 individual cases from lymphocyte subset assays. Our proposed method attained 97.7 % accuracy for all cases and 100 % for the high-confidence cases. With our automated method, 99.1 % of manual labor can be saved when reviewing only the low-confidence cases, while the average turnaround time required is only 29 s, reducing by 83.7 %. CONCLUSIONS: Our proposed method can achieve high accuracy in flow cytometry data from lymphocyte subset assays. Additionally, it can save manual labor and reduce the turnaround time, making it have the potential for application in the laboratory.


Assuntos
Citometria de Fluxo , Subpopulações de Linfócitos , Subpopulações de Linfócitos/classificação , Subpopulações de Linfócitos/citologia , Citometria de Fluxo/métodos , Citometria de Fluxo/normas , Automação Laboratorial , Reprodutibilidade dos Testes , Humanos
8.
Int J Lab Hematol ; 46(3): 488-494, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38114449

RESUMO

INTRODUCTION: Lymphocyte subset enumeration by flow cytometry is important for the therapeutic monitoring of a range of conditions. However, current bead-based methodologies do not produce metrologically traceable results. Here we compare an established bead-based methodology with a volumetric-based system traceable to an internationally recognised reference method. METHOD: A total of 118 samples received for lymphocyte subset analysis were tested using an established bead-based technique (BD Multitest™ 6-colour TBNK assay using Trucount™ tubes on a BD FACSLyric flow cytometer), followed by a volumetric method on the Sysmex XF-1600 flow cytometer using Exbio Kombitest 6-colour TBNK reagent. All samples were tested in accordance with the manufacturer's instructions. RESULTS: Absolute count values from both methodologies for CD3+, CD3 + CD4+, CD3 + CD8+, CD19+ and CD3-CD16+/CD56+ lymphocyte populations were compared using linear regression (R2 for all parameters >0.95) and Bland-Altman analysis. There was no significant bias (where p < 0.05) for absolute CD3 + CD4+ lymphocytes in the defined therapeutic range of 0-250 cells/µL (mean bias: 0.27 cells/µL). Although positive biases were seen for CD3 + CD4+ lymphocytes (over the entire range tested: 14-1798 cells/µL) and CD3-CD16+/CD56+ lymphocytes (mean bias: 10.83 cells/µL and 6.79 cells/µL, respectively). Negative biases were seen for CD3 + CD8+ and CD19+ lymphocytes (mean bias: -29.17 cells/µL and - 18.76 cells/µL, respectively). CONCLUSION: A high degree of correlation was found for results from both methodologies and observed bias was within the limits of clinical acceptability for all populations. This shows that the metrologically traceable lymphocyte subset absolute counts produced by the Sysmex XF-1600 are robust within clinically required limits.


Assuntos
Citometria de Fluxo , Subpopulações de Linfócitos , Citometria de Fluxo/métodos , Citometria de Fluxo/normas , Humanos , Contagem de Linfócitos/normas , Contagem de Linfócitos/métodos , Antígenos CD/análise , Imunofenotipagem/normas , Imunofenotipagem/métodos , Feminino
9.
Cells ; 12(6)2023 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-36980191

RESUMO

Mesenchymal stromal cells (MSCs) have the potential to suppress pathological activation of immune cells and have therefore been considered for the treatment of Graft-versus-Host-Disease. The clinical application of MSCs requires a process validation to ensure consistent quality. A flow cytometry-based mixed lymphocyte reaction (MLR) was developed to analyse the inhibitory effect of MSCs on T cell proliferation. Monoclonal antibodies were used to stimulate T cell expansion and determine the effect of MSCs after four days of co-culture based on proliferation tracking with the violet proliferation dye VPD450. Following the guidelines of the International Council for Harmonisation (ICH) Q2 (R1), the performance of n = 30 peripheral blood mononuclear cell (PBMC) donor pairs was assessed. The specific inhibition of T cells by viable MSCs was determined and precision values of <10% variation for repeatability and <15% for intermediate precision were found. Compared to a non-compendial reference method, a linear correlation of r = 0.9021 was shown. Serial dilution experiments demonstrated a linear range for PBMC:MSC ratios from 1:1 to 1:0.01. The assay was unaffected by PBMC inter-donor variability. In conclusion, the presented MLR can be used as part of quality control tests for the validation of MSCs as a clinical product.


Assuntos
Citometria de Fluxo , Doença Enxerto-Hospedeiro , Teste de Cultura Mista de Linfócitos , Células-Tronco Mesenquimais , Teste de Cultura Mista de Linfócitos/métodos , Humanos , Células-Tronco Mesenquimais/citologia , Leucócitos Mononucleares/citologia , Controle de Qualidade , Citometria de Fluxo/métodos , Citometria de Fluxo/normas , Linfócitos T/citologia , Proliferação de Células , Doença Enxerto-Hospedeiro/terapia
10.
Front Immunol ; 13: 759188, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35126389

RESUMO

Intracellular cytokine staining (ICS) is a widely employed ex vivo method for quantitative determination of the activation status of immune cells, most often applied to T cells. ICS test samples are commonly prepared from animal or human tissues as unpurified cell mixtures, and cell-specific cytokine signals are subsequently discriminated by gating strategies using flow cytometry. Here, we show that when ICS samples contain Ly6G+ neutrophils, neutrophils are ex vivo activated by an ICS reagent - phorbol myristate acetate (PMA) - which leads to hydrogen peroxide (H2O2) release and death of cytokine-expressing T cells. This artifact is likely to result in overinterpretation of the degree of T cell suppression, misleading immunological research related to cancer, infection, and inflammation. We accordingly devised easily implementable improvements to the ICS method and propose alternative methods for assessing or confirming cellular cytokine expression.


Assuntos
Biomarcadores , Citocinas/metabolismo , Ativação Linfocitária , Linfócitos T/imunologia , Linfócitos T/metabolismo , Animais , Artefatos , Neoplasias da Mama , Linhagem Celular , Modelos Animais de Doenças , Feminino , Citometria de Fluxo/métodos , Citometria de Fluxo/normas , Humanos , Peróxido de Hidrogênio/metabolismo , Espaço Intracelular , Contagem de Leucócitos , Ativação Linfocitária/genética , Ativação Linfocitária/imunologia , Camundongos , Camundongos Knockout , Modelos Biológicos , Neutrófilos/metabolismo , Neutrófilos/patologia
11.
Int J Mol Sci ; 23(2)2022 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-35055086

RESUMO

Chimeric-antigen-receptor (CAR)-T-cell therapy is already widely used to treat patients who are relapsed or refractory to chemotherapy, antibodies, or stem-cell transplantation. Multiple myeloma still constitutes an incurable disease. CAR-T-cell therapy that targets BCMA (B-cell maturation antigen) is currently revolutionizing the treatment of those patients. To monitor and improve treatment outcomes, methods to detect CAR-T cells in human peripheral blood are highly desirable. In this study, three different detection reagents for staining BCMA-CAR-T cells by flow cytometry were compared. Moreover, a quantitative polymerase chain reaction (qPCR) to detect BCMA-CAR-T cells was established. By applying a cell-titration experiment of BCMA-CAR-T cells, both methods were compared head-to-head. In flow-cytometric analysis, the detection reagents used in this study could all detect BCMA-CAR-T cells at a similar level. The results of false-positive background staining differed as follows (standard deviation): the BCMA-detection reagent used on the control revealed a background staining of 0.04% (±0.02%), for the PE-labeled human BCMA peptide it was 0.25% (±0.06%) and for the polyclonal anti-human IgG antibody it was 7.2% (±9.2%). The ability to detect BCMA-CAR-T cells down to a concentration of 0.4% was similar for qPCR and flow cytometry. The qPCR could detect even lower concentrations (0.02-0.01%). In summary, BCMA-CAR-T-cell monitoring can be reliably performed by both flow cytometry and qPCR. In flow cytometry, reagents with low background staining should be preferred.


Assuntos
Antígeno de Maturação de Linfócitos B/metabolismo , Citometria de Fluxo , Reação em Cadeia da Polimerase , Receptores de Antígenos Quiméricos/metabolismo , Linfócitos T/metabolismo , Antígeno de Maturação de Linfócitos B/genética , Biomarcadores , Citometria de Fluxo/métodos , Citometria de Fluxo/normas , Humanos , Imunofenotipagem , Imunoterapia Adotiva/métodos , Imunoterapia Adotiva/normas , Reação em Cadeia da Polimerase/métodos , Reação em Cadeia da Polimerase/normas , Reação em Cadeia da Polimerase em Tempo Real , Receptores de Antígenos Quiméricos/genética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Linfócitos T/imunologia
12.
Int J Lab Hematol ; 44(1): 177-185, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34609044

RESUMO

INTRODUCTION: Clot retraction is a pivotal process for haemostasis, where platelets develop a contractile force in fibrin meshwork and lead to the increased rigidity of clot. The pathophysiological alteration in contractile forces generated by the platelet-fibrin meshwork can lead to haemostatic disorders. Regardless of its utter significance, clot retraction remains a limited understood process owing to lack of quantification methodology. Sonoclot analysis is a point-of-care technique used in clinical laboratories for whole blood analysis that provides in vitro qualitative as well as quantitative assessment of coagulation process from initial fibrin formation to clot retraction. METHODS: Human washed platelets were isolated by differential centrifugation method and analysed via optical imaging, microscopy and Sonoclot analysis using 1-2 × 108 /mL of washed platelets, 1 U/mL of thrombin, 1 mg/mL of fibrinogen and 1 mM of calcium chloride. RESULTS: In this study, we demonstrate the novelty of this instrument in the quantitative evaluation of clot retraction in washed platelets and attempted to optimize the reference range of Sonoclot parameters including ACT - 87.3 ± 20.997, CR - 16.23 ± 3.538 and PF - 3.57 ± 0.629, (n = 10). DISCUSSION: Sonoclot analysis provides a simple and quantitative method to better understand in vitro clot retraction and its modulation by retraction components including platelet count, fibrinogen and platelet-fibrin interaction compared with existing conventional methods. Sonoclot may prove to be a valuable tool in thrombus biology research to understand fundamental basis of blood clot retraction.


Assuntos
Testes de Coagulação Sanguínea/métodos , Testes de Coagulação Sanguínea/normas , Plaquetas , Retração do Coágulo , Testes de Função Plaquetária/métodos , Testes de Função Plaquetária/normas , Coagulação Sanguínea , Testes de Coagulação Sanguínea/instrumentação , Cálcio/sangue , Citometria de Fluxo/métodos , Citometria de Fluxo/normas , Voluntários Saudáveis , Hemostasia , Humanos , Microscopia de Contraste de Fase/métodos , Microscopia de Contraste de Fase/normas , Contagem de Plaquetas , Testes de Função Plaquetária/instrumentação
13.
Int J Lab Hematol ; 44(1): 82-87, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34409726

RESUMO

INTRODUCTION: Stem cell enumeration by the hematopoietic progenitor cells (HPC) mode is a novel method available from Sysmex XN2000 hematology analyzer. A small amount of blood (190 µL) is required, and the results are available in a few minutes without manual gating or presample treatment. The present study compares stem cell measurements using XN2000 analyzer HPC mode and FC500 flow cytometry analyzer using peripheral blood (PB) specimens and apheresis products. METHODS: In this prospective study, CD34-positive cell counts were enumerated using an FC500 flow cytometry analyzer and compared with XN2000 Sysmex analyzer (XN-HPC mode) in the same samples. Results were compared using Bland-Altman plots. RESULTS: A total of 103 samples were used. In the PB samples, the median HPC count and CD34-positive cells were 83.5 × 106 /L and 78.0 × 106 /L, respectively. The mean Bland-Altman difference was 4.5 × 106 /L (Limits: -51.7 to 60.7 × 106 /L), with a Pearson's correlation of 0.79. In the apheresis products, the median HPC count and CD34-positive cells were 1468 × 106 /L (IQR: 1049 - 1960 × 106 /L) and 1327 × 106 /L (IQR: 910 - 2001 × 106 /L), respectively. The mean Bland-Altman difference was 179.0 × 106 /L (Limits: -2022.2 - 2380.2 × 106 /L), with a Pearson's correlation of 0.58. CONCLUSION: The XN-HPC mode has an excellent correlation and minimal disagreement for stem cell enumeration in PB compared with flow cytometry and could replace it. There is high disagreement in apheresis products, and therefore, the XN-HPC mode cannot be recommended.


Assuntos
Biomarcadores , Citometria de Fluxo/instrumentação , Citometria de Fluxo/métodos , Células-Tronco Hematopoéticas/metabolismo , Antígenos CD34/metabolismo , Células Sanguíneas/citologia , Células Sanguíneas/metabolismo , Remoção de Componentes Sanguíneos/métodos , Células da Medula Óssea/citologia , Células da Medula Óssea/metabolismo , Citometria de Fluxo/normas , Hematologia/instrumentação , Hematologia/métodos , Transplante de Células-Tronco Hematopoéticas , Células-Tronco Hematopoéticas/citologia , Humanos , Imunofenotipagem/instrumentação , Imunofenotipagem/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Doadores de Tecidos
14.
Int J Lab Hematol ; 44(1): 96-103, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34582122

RESUMO

INTRODUCTION: Body fluid cell counting and differentiation provide essential information for diagnosis and monitoring of diverse pathologies. We evaluated the performance of the newly launched Abbott Alinity hq hematology analyzer for automated cell counting in body fluids and compared red blood cell (RBC) and total nucleated cell (TNC) counts with the Cell-Dyn Sapphire automated hematology analyzer. Differential counts were compared with microscopic differentiation on cytocentrifuged preparations. METHODS: Background concentration limits, limit of detection (LOD), linearity, imprecision, functional sensitivity and carryover were evaluated. For method comparison, we collected 172 body fluids (17 continuous ambulatory peritoneal dialysis fluids, 56 cerebrospinal fluids and 99 serous fluids). RESULTS: Background concentration limits were ≤1000 cells/µL for RBC counts and ≤3 cells/µL for TNC counts. The LOD was 1000 RBC/µL and 5 TNC/µL. Results from linear regression analysis revealed excellent linearity. Functional sensitivity was 3000 cells/µL for RBC counts and 50 cells/µL for TNC counts. Carryover was 0.6% and 0.1% for TNC and RBC, respectively. The Alinity hq shows good clinical performance. CONCLUSION: We demonstrated comparable performance for body fluid cell counting between the Alinity hq analyzer and the Cell-Dyn Sapphire. The Alinity hq can be very useful as a screening tool for body fluid cell counting.


Assuntos
Contagem de Células Sanguíneas/instrumentação , Contagem de Células Sanguíneas/métodos , Líquidos Corporais/citologia , Automação Laboratorial , Contagem de Células Sanguíneas/normas , Eritrócitos , Citometria de Fluxo/métodos , Citometria de Fluxo/normas , Humanos , Contagem de Leucócitos , Microscopia/métodos , Microscopia/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Int J Lab Hematol ; 44(1): 118-126, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34585519

RESUMO

INTRODUCTION: Monitoring patients with acute myeloid leukemia can be implemented through various techniques such as multiparameter flow cytometry, real-time quantitative polymerase chain reaction, and next-generation sequencing. However, there is scarce studies when comparing the data of next-generation sequencing and flow cytometry for monitoring disease progression, particularly how they might supplement one another when used in tandem. METHODS: We investigated 107 patients via retrospective analysis using follow-up MFC and NGS data with a total of 717 MFC and 247 NGS studies to compare these methods in monitoring minimal/measurable residual disease. RESULTS: 197 instances were MFC+ /NGS+ , 3 were MFC- /NGS- , 44 were MFC- /NGS+ , and 3 are MFC+ /NGS- . The majority of the MFC- /NGS+ cases occurred within 6 months during the post-treatment phase (64%). Among 44 MFC- /NGS+ instances, 13 had similar NGS profiles to their original day 0 diagnosis. The remaining cases showed preleukemic clonal hematopoiesis mutations, "likely pathogenic mutations," or "variants of uncertain significance." CONCLUSION: Our findings show that flow cytometry has its advantages with comparable sensitivity in detecting minimal/measurable residual disease. Next-generation sequencing could be used in an increased and more regular capacity in conjunction with flow cytometry to achieve a more comprehensive surveillance of these patients, resulting in improved outcomes.


Assuntos
Citometria de Fluxo/métodos , Citometria de Fluxo/normas , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Sequenciamento de Nucleotídeos em Larga Escala/normas , Leucemia Mieloide Aguda/diagnóstico , Neoplasia Residual/diagnóstico , Biomarcadores Tumorais , Gerenciamento Clínico , Humanos , Imunofenotipagem , Leucemia Mieloide Aguda/etiologia , Leucemia Mieloide Aguda/metabolismo , Mutação , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
16.
Br J Haematol ; 196(2): 374-379, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34476808

RESUMO

High-sensitivity multicolour flow cytometry (MFC)-based B-lymphoblastic leukaemia (B-ALL) measurable residual disease (BMRD) assay is increasingly being used in clinical practice. Herein, we describe six consistently present low-level populations immunophenotypically mimicking abnormal B-ALL blasts in 441 BMRD samples from 301 children. These included CD19+ CD123+ plasmacytoid dendritic cells differentiating from lymphoid precursors, CD10+ transitional B cells with CD10+ /CD38dim-to-negative/CD20bright/CD45bright phenotype, CD19+ natural killer (NK) cells, CD73bright/CD10+ mesenchymal stromal/stem cells, CD73bright/CD34+ endothelial cells, and a CD34+ CD38dim-to-negative/CD10- /CD20bright/CD45bright subset of mature B cells. We provide the proportions, comprehensive immunophenotype, and practical clues for proper identification of these low-level populations. Knowledge regarding the presence and immunophenotype of these mimics is essential for accurate interpretation in high-sensitivity MFC-BMRD analysis.


Assuntos
Citometria de Fluxo/métodos , Imunofenotipagem/métodos , Neoplasia Residual/diagnóstico , Leucemia-Linfoma Linfoblástico de Células Precursoras B/diagnóstico , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Artefatos , Biomarcadores Tumorais , Tomada de Decisão Clínica , Gerenciamento Clínico , Citometria de Fluxo/normas , Humanos , Imunofenotipagem/normas , Quimioterapia de Indução , Leucemia-Linfoma Linfoblástico de Células Precursoras B/etiologia , Leucemia-Linfoma Linfoblástico de Células Precursoras B/terapia , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
17.
Front Immunol ; 12: 768113, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34868024

RESUMO

Spectral flow cytometry is an upcoming technique that allows for extensive multicolor panels, enabling simultaneous investigation of a large number of cellular parameters in a single experiment. To fully explore the resulting high-dimensional single cell datasets, high-dimensional analysis is needed, as opposed to the common practice of manual gating in conventional flow cytometry. However, preparing spectral flow cytometry data for high-dimensional analysis can be challenging, because of several technical aspects. In this article, we will give insight into the pitfalls of handling spectral flow cytometry datasets. Moreover, we will describe a workflow to properly prepare spectral flow cytometry data for high dimensional analysis and tools for integrating new data at later time points. Using healthy control data as example, we will go through the concepts of quality control, data cleaning, transformation, correcting for batch effects, subsampling, clustering and data integration. This methods article provides an R-based pipeline based on previously published packages, that are readily available to use. Application of our workflow will aid spectral flow cytometry users to obtain valid and reproducible results.


Assuntos
Análise de Dados , Citometria de Fluxo/métodos , Fluxo de Trabalho , Conjuntos de Dados como Assunto , Citometria de Fluxo/normas , Humanos , Controle de Qualidade
19.
Cells ; 10(11)2021 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-34831104

RESUMO

Inflammasome activation is linked to the aggregation of the adaptor protein ASC into a multiprotein complex, known as the ASC speck. Redistribution of cytosolic ASC to this complex has been widely used as a readout for inflammasome activation and precedes the downstream proteolytic release of the proinflammatory cytokines, IL-1ß and IL-18. Although inflammasomes are important for many diseases such as periodic fever syndromes, COVID-19, gout, sepsis, atherosclerosis and Alzheimer's disease, only a little knowledge exists on the precise and cell type specific occurrence of inflammasome activation in patient samples ex vivo. In this report, we provide detailed information about the optimal conditions to reliably identify inflammasome activated monocytes by ASC speck formation using a modified flow cytometric method introduced by Sester et al. in 2015. Since no protocol for optimal sample processing exists, we tested human blood samples for various conditions including anticoagulant, time and temperature, the effect of one freeze-thaw cycle for PBMC storage, and the fast generation of a positive control. We believe that this flow cytometric protocol will help researchers to perform high quality translational research in multicenter studies, and therefore provide a basis for investigating the role of the inflammasome in the pathogenesis of various diseases.


Assuntos
Proteínas Adaptadoras de Sinalização CARD/metabolismo , Citometria de Fluxo/métodos , Inflamassomos/imunologia , Anticoagulantes , Citometria de Fluxo/normas , Humanos , Inflamassomos/metabolismo , Leucócitos Mononucleares/citologia , Leucócitos Mononucleares/imunologia , Leucócitos Mononucleares/metabolismo , Monócitos/citologia , Monócitos/imunologia , Monócitos/metabolismo , Manejo de Espécimes , Temperatura , Fatores de Tempo
20.
J Clin Lab Anal ; 35(11): e23834, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34636443

RESUMO

BACKGROUND: Flow cytometry is a powerful technique that provides information regarding cell properties. In this study, we evaluated the analytical performance of a new flow cytometer, the 10-color BD FACSLyricTM , which could help doctors obtain reliable test results prior to clinical research. METHODS: We used SpheroTM Rainbow Calibration Particles and the SpheroTM Nano Fluorescent Particle Size Standard Kit to validate the fluorescence sensitivity and linearity. The Beckman Coulter IMMUNO-TROL Cell was used as the quality control to evaluate the accuracy and reproducibility of surface markers detected by the flow cytometer. Furthermore, BD Calibrate APC Beads and CS&T Research Beads were applied to calculate the carry-over contamination rate and assess the instrument stability. RESULTS: A linear regression equation between the molecules of equivalent soluble fluorochrome and fluorescence detection limit showed a good linear fit (R2  > 0.99). The minimum bead size detected by side scatter was 0.22 µm. The coefficient of variation percentage of each fluorescence channel was below 2%, and the carry-over contamination rate of the cytometer was under 0.2%. After running the BD FACSLyricTM cytometer continuously for 8 h, the median fluorescence index of particles remained close to that at the time of cytometer startup. CONCLUSIONS: The 10-color BD FACSLyricTM cytometer showed good performance in the evaluation performed in this study and may be trusted to provide accurate results for clinical research.


Assuntos
Citometria de Fluxo/métodos , Citometria de Fluxo/normas , Animais , Humanos , Limite de Detecção , Modelos Lineares , Subpopulações de Linfócitos/citologia , Reprodutibilidade dos Testes