Resultados 1 - 20 de 787
Filtrar
1.
J Clin Apher ; 39(3): e22114, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38708583

RESUMO

BACKGROUND: Stem cell apheresis in the context of autologous stem cell transplantation requires an accurate cluster of differentiantion 34 (CD34+) count determined by flow cytometry as the current gold standard. Since flow cytometry is a personnel and time-intensive diagnostic tool, automated stem cell enumeration may provide a promising alternative. Hence, this study aimed to compare automated hematopoietic progenitor enumeration carried out on a Sysmex XN-20 module compared with conventional flow cytometric measurements. METHODS: One hundred forty-three blood samples from 41 patients were included in this study. Correlation between the two methods was calculated over all samples, depending on leukocyte count and diagnosis. RESULTS: Overall, we found a high degree of correlation (r = 0.884). Furthermore, correlation was not impaired by elevated leukocyte counts (>10 000/µL, r = 0.860 vs <10 000/µL, r = 0.849; >20 000/µL, r = 0.843 vs <20 000/µL, r = 0.875). However, correlation was significantly impaired in patients with multiple myeloma (multiple myeloma r = 0.840 vs nonmyeloma r = 0.934). SUMMARY: Stem cell measurement carried out on the Sysmex XN-20 module provides a significant correlation with flow cytometry and might be implemented in clinical practice. In clinical decision-making, there was discrepancy of under 15% of cases. In multiple myeloma patients, XN-20 should be used with caution.


Assuntos
Antígenos CD34 , Citometria de Fluxo , Células-Tronco Hematopoéticas , Humanos , Citometria de Fluxo/métodos , Antígenos CD34/análise , Antígenos CD34/sangue , Células-Tronco Hematopoéticas/citologia , Mieloma Múltiplo/sangue , Mieloma Múltiplo/diagnóstico , Masculino , Feminino , Contagem de Células Sanguíneas/métodos , Contagem de Células Sanguíneas/instrumentação , Pessoa de Meia-Idade , Contagem de Leucócitos , Adulto
2.
Int J Lab Hematol ; 46(3): 466-473, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38263481

RESUMO

INTRODUCTION: Cell population data (CPD) parameters may be putative biomarkers for the screening of various diseases including some infections and myelodysplastic syndrome. This study aimed to establish the age- and sex-specific reference intervals (RIs) for the CPD parameters in the Korean population. METHODS: The reference population for the RIs of CPD parameters comprised 124 856 subjects aged 20-99 years. CPD parameters were obtained from Sysmex XN-2000 (Kobe, Japan) datasets from 17 health promotion centers in 13 South Korean cities. We determined significant partitions for age and sex, and calculated RIs according to Clinical and Laboratory Standards Institute C28-A3 guidelines. RESULTS: The side scattered light intensity in the neutrophil area and the lymphocyte area did not require sex-related partitioning except in those over the age of 50, among whom the lower limit (LL) and upper limit (UL) were lower in females. However, the side scattered light distribution width in the lymphocyte area required age- and sex-related partitioning, in which LL and UL were higher in females. The LL and UL of the fluorescent light distribution width were higher in males in the neutrophil area and higher in females in the lymphocyte area, but age-related partitioning was not required. The forward scattered light intensity in the neutrophil area, lymphocyte area, and monocyte area did not require age-related partitioning in males. CONCLUSION: This study has determined comprehensive age- and sex-specific RIs for CPD parameters, which could help to prove the clinical significance of these parameters in the Sysmex XN-2000.


Assuntos
Neutrófilos , Humanos , Masculino , Feminino , Idoso , República da Coreia , Adulto , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Valores de Referência , Contagem de Células Sanguíneas/instrumentação , Contagem de Células Sanguíneas/normas , Contagem de Células Sanguíneas/métodos , Fatores Etários , Adulto Jovem , Neutrófilos/citologia , Envelhecimento
3.
Int J Mol Sci ; 23(21)2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36362146

RESUMO

Blood cell detection is an essential branch of microscopic imaging for disease diagnosis. TE-YOLOF is an effective model for blood cell detection, and was recently found to have an outstanding trade-off between accuracy and model complexity. However, there is a lack of understanding of whether the dilated encoder in TE-YOLOF works well for blood cell detection. To address this issue, we perform a thorough experimental analysis and find the interesting fact that the dilated encoder is not necessary for TE-YOLOF to perform the blood cell detection task. For the purpose of increasing performance on blood cell detection, in this research, we use the attention mechanism to dominate the dilated encoder place in TE-YOLOF and find that the attention mechanism is effective to address this problem. Based upon these findings, we propose a novel approach, named Enhanced Channel Attention Module (ECAM), based on attention mechanism to achieve precision improvement with less growth on model complexity. Furthermore, we examine the proposed ECAM method compared with other tip-top attention mechanisms and find that the proposed attention method is more effective on blood cell detection task. We incorporate the spatial attention mechanism in CBAM with our ECAM to form a new module, which is named Enhanced-CBAM. We propose a new network named Enhanced Channel Attention Network (ENCANet) based upon Enhanced-CBAM to perform blood cell detection on BCCD dataset. This network can increase the accuracy to 90.3 AP while the parameter is only 6.5 M. Our ENCANet is also effective for conducting cross-domain blood cell detection experiments.


Assuntos
Contagem de Células Sanguíneas , Humanos , Contagem de Células Sanguíneas/instrumentação
4.
Int J Lab Hematol ; 44(1): 96-103, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34582122

RESUMO

INTRODUCTION: Body fluid cell counting and differentiation provide essential information for diagnosis and monitoring of diverse pathologies. We evaluated the performance of the newly launched Abbott Alinity hq hematology analyzer for automated cell counting in body fluids and compared red blood cell (RBC) and total nucleated cell (TNC) counts with the Cell-Dyn Sapphire automated hematology analyzer. Differential counts were compared with microscopic differentiation on cytocentrifuged preparations. METHODS: Background concentration limits, limit of detection (LOD), linearity, imprecision, functional sensitivity and carryover were evaluated. For method comparison, we collected 172 body fluids (17 continuous ambulatory peritoneal dialysis fluids, 56 cerebrospinal fluids and 99 serous fluids). RESULTS: Background concentration limits were ≤1000 cells/µL for RBC counts and ≤3 cells/µL for TNC counts. The LOD was 1000 RBC/µL and 5 TNC/µL. Results from linear regression analysis revealed excellent linearity. Functional sensitivity was 3000 cells/µL for RBC counts and 50 cells/µL for TNC counts. Carryover was 0.6% and 0.1% for TNC and RBC, respectively. The Alinity hq shows good clinical performance. CONCLUSION: We demonstrated comparable performance for body fluid cell counting between the Alinity hq analyzer and the Cell-Dyn Sapphire. The Alinity hq can be very useful as a screening tool for body fluid cell counting.


Assuntos
Contagem de Células Sanguíneas/instrumentação , Contagem de Células Sanguíneas/métodos , Líquidos Corporais/citologia , Automação Laboratorial , Contagem de Células Sanguíneas/normas , Eritrócitos , Citometria de Fluxo/métodos , Citometria de Fluxo/normas , Humanos , Contagem de Leucócitos , Microscopia/métodos , Microscopia/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Int J Lab Hematol ; 44(1): 88-95, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34464032

RESUMO

INTRODUCTION: Mortality rates are used to evaluate the quality of hospital care after adjusting for disease severity and, commonly also, for age, comorbidity, and laboratory data with only few parameters of the complete blood count (CBC). OBJECTIVE: To identify the parameters of the CBC that predict independently in-hospital mortality of acutely admitted patients. POPULATION: All patients were admitted to internal medicine, cardiology, and intensive care departments at the Laniado Hospital in Israel in 2018 and 2019. VARIABLES: Independent variables were patients' age, sex, and parameters of the CBC. The outcome variable was in-hospital mortality. ANALYSIS: Logistic regression. In 2018, we identified the variables that were associated with in-hospital mortality and validated this association in the 2019 cohort. RESULTS: In the validation cohort, a model consisting of nine parameters that are commonly available in modern analyzers had a c-statistics (area under the receiver operator curve) of 0.86 and a 10%-90% risk gradient of 0%-21.4%. After including the proportions of large unstained cells, hypochromic, and macrocytic red cells, the c-statistic increased to 0.89, and the risk gradient to 0.1%-29.5%. CONCLUSION: The commonly available parameters of the CBC predict in-hospital mortality. Addition of the proportions of hypochromic red cells, macrocytic red cells, and large unstained cells may improve the predictive value of the CBC.


Assuntos
Biomarcadores , Contagem de Células Sanguíneas , Mortalidade Hospitalar , Hospitalização/estatística & dados numéricos , Qualidade da Assistência à Saúde/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Contagem de Células Sanguíneas/instrumentação , Contagem de Células Sanguíneas/métodos , Contagem de Células Sanguíneas/normas , Feminino , Pesquisas sobre Atenção à Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Valor Preditivo dos Testes
6.
Int J Lab Hematol ; 43(6): 1309-1318, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34523805

RESUMO

INTRODUCTION: Developing prognostic markers can be useful for clinical decision-making. Peripheral blood (PB) examination is simple and basic that can be performed in any facility. We aimed to investigate whether PB examination can predict prognosis in coronavirus disease (COVID-19). METHODS: Complete blood count (CBC) and PB cell morphology were examined in 38 healthy controls (HCs) and 40 patients with COVID-19. Patients with COVID-19, including 26 mild and 14 severe cases, were hospitalized in Juntendo University Hospital (Tokyo, Japan) between April 1 and August 6, 2020. PB examinations were performed using Sysmex XN-3000 automated hematology analyzer and Sysmex DI-60 employing the convolutional neural network-based automatic image-recognition system. RESULTS: Compared with mild cases, severe cases showed a significantly higher incidence of anemia, lymphopenia, and leukocytosis (P < .001). Granular lymphocyte counts were normal or higher in mild cases and persistently decreased in fatal cases. Temporary increase in granular lymphocytes was associated with survival of patients with severe infection. Red cell distribution width was significantly higher in severe cases than in mild cases (P < .001). Neutrophil dysplasia was consistently observed in COVID-19 cases, but not in HCs. Levels of giant neutrophils and toxic granulation/Döhle bodies were increased in severe cases. CONCLUSION: Basic PB examination can be useful to predict the prognosis of COVID-19, by detecting SARS-CoV-2 infection-induced multi-lineage changes in blood cell counts and morphological anomalies. These changes were dynamically correlated with disease severity and may be associated with disruption of hematopoiesis and the immunological system due to bone marrow stress in severe infection.


Assuntos
Contagem de Células Sanguíneas , COVID-19/sangue , Leucocitose/etiologia , Linfócitos/ultraestrutura , Linfopenia/etiologia , Neutrófilos/ultraestrutura , SARS-CoV-2 , Idoso , Anemia/sangue , Anemia/etiologia , Contagem de Células Sanguíneas/instrumentação , Contagem de Células Sanguíneas/métodos , COVID-19/mortalidade , Forma Celular , Grânulos Citoplasmáticos/ultraestrutura , Índices de Eritrócitos , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Leucocitose/sangue , Contagem de Linfócitos , Linfopenia/sangue , Masculino , Pessoa de Meia-Idade , Redes Neurais de Computação , Prognóstico , Índice de Gravidade de Doença
7.
PLoS Negl Trop Dis ; 15(8): e0009692, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34398882

RESUMO

BACKGROUND: Hematocrit measurement has been an indispensable tool for monitoring plasma leakage and bleeding in dengue patients. However, hematocrit measurement by automated methods is hampered by frequent venipunctures. Utility of point-of-care hemoglobin (POC-Hb) test for monitoring dengue patients has not been established. We evaluated the relationship between hemoglobin measured by POC-Hb testing and hematocrit measured by the automated method in adult dengue patients. METHODOLOGY AND PRINCIPAL FINDINGS: Adult dengue patients were recruited at two university hospitals in Thailand from October 2019 to December 2020. POC-Hb test was performed using capillary blood simultaneously with venipuncture to obtain whole blood for an automated complete blood count (CBC) analysis. The correlation of hemoglobin and hematocrit measurement was evaluated. A total of 44 dengue patients were enrolled. Twenty-nine patients (65.9%) were female, with a median age of 31 years (interquartile range 22-41). Of the enrolled patients, 30 (68.2%), 11 (25.0%), and 3 (6.8%) were classified as dengue without warning signs, with warning signs, and severe dengue, respectively. Seven patients (15.9%) had hemoconcentration, and five patients (11.3%) had bleeding. A total of 216 pairs of POC-Hb and CBC were evaluated. A significant positive correlation was observed between hemoglobin measured by POC-Hb testing and hematocrit measured by an automated CBC (r = 0.869, p <0.001). Bland-Altman analysis between hemoglobin measured by POC-Hb testing and an automated CBC showed a bias of -0.43 (95% limit of agreement of -1.81 and 0.95). Using the cutoff of POC-Hb ≥20% as a criteria for hemoconcentration, the sensitivity and specificity of hemoconcentration detected by POC-Hb device were 71.4% and 100.0%, respectively. CONCLUSIONS: Hemoglobin measurement by POC-Hb testing has a strong correlation with hematocrit in adult patients with dengue fever. However, the sensitivity in detecting hemoconcentration is fair. The adjunct use of capillary POC-Hb testing can decrease the frequency of venipuncture. Further study in children is encouraged.


Assuntos
Contagem de Células Sanguíneas/métodos , Dengue/sangue , Hematócrito/métodos , Hemoglobinas/análise , Testes Imediatos , Adulto , Contagem de Células Sanguíneas/instrumentação , Feminino , Hematócrito/instrumentação , Humanos , Masculino , Estudos Prospectivos , Tailândia , Adulto Jovem
8.
Am J Hematol ; 96(10): 1264-1274, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34264525

RESUMO

Hematology analyzers capable of performing complete blood count (CBC) have lagged in their prevalence at the point-of-care. Sight OLO (Sight Diagnostics, Israel) is a novel hematological platform which provides a 19-parameter, five-part differential CBC, and is designed to address the limitations in current point-of-care hematology analyzers using recent advances in artificial intelligence (AI) and computer vision. Accuracy, repeatability, and flagging capabilities of OLO were compared with the Sysmex XN-Series System (Sysmex, Japan). Matrix studies compared performance using venous, capillary and direct-from-fingerprick blood samples. Regression analysis shows strong concordance between OLO and the Sysmex XN, demonstrating that OLO performs with high accuracy for all CBC parameters. High repeatability and reproducibility were demonstrated for most of the testing parameters. The analytical performance of the OLO hematology analyzer was validated in a multicenter clinical laboratory setting, demonstrating its accuracy and comparability to clinical laboratory-based hematology analyzers. Furthermore, the study demonstrated the validity of CBC analysis of samples collected directly from fingerpricks.


Assuntos
Inteligência Artificial , Contagem de Células Sanguíneas/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito , Contagem de Células Sanguíneas/métodos , Desenho de Equipamento , Humanos , Reprodutibilidade dos Testes
9.
Cells ; 10(5)2021 05 18.
Artigo em Inglês | MEDLINE | ID: mdl-34069775

RESUMO

The analysis of cells in the cerebrospinal fluid (CSF) is a routine procedure that is usually performed manually using the Fuchs-Rosenthal chamber and cell microscopy for cell counting and differentiation. In order to reduce the requirement for manual assessment, automated analyses by devices mainly used for blood cell analysis have been also used for CSF samples. Here, we summarize the current state of investigations using these automated devices and critically review their limitations. Despite technical improvements, the lower limit for reliable leukocyte counts in the CSF is still at approximately 20 cells/µL, to be validated depending on the device. Since the critical range for clinical decisions is in the range of 5-30 cells/µL this implies that cell numbers < 30/µL require a manual confirmation. Moreover, the lower limit of reliable erythrocyte detection by automated devices is at approximately 1000/µL. However, even low erythrocyte numbers may be of clinical importance. In contrast, heavily hemorrhagic samples from neurosurgery may be counted automatically at an acceptable precision more quickly. Finally, cell differentiation by automated devices provides only a rough orientation for lymphocytes, granulocytes and monocytes. Other diagnostically important cell types such as tumor cells, siderophages, blasts and others are not reliably detected. Thus, although the automation may give a gross estimate sufficient for the emergency room situation, each CSF requires a manual microscopy for cytological evaluation for the final report. In conclusion, although automated analysis of CSF cells may provide a first orientation of the cell profile in an individual sample, an additional manual cell count and a microscopic cytology are still required and represent the gold standard.


Assuntos
Contagem de Células Sanguíneas/instrumentação , Células Sanguíneas , Líquido Cefalorraquidiano/citologia , Automação Laboratorial , Desenho de Equipamento , Contagem de Eritrócitos/instrumentação , Humanos , Contagem de Linfócitos/instrumentação , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
10.
Int J Lab Hematol ; 43(5): 973-982, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33750012

RESUMO

INTRODUCTION: Point of care testing (POCT) represents a valuable option when laboratory data shall be urgently available for timely clinical management, with a turnaround time (TAT) that is unfeasible using conventional laboratory instrumentation. This study was aimed to compare the performance of QBC STAR™ compared to Sysmex XN-module and the reference optical microscopy (OM) assessment. MATERIAL AND METHODS: One hundred peripheral blood samples, collected in K3 EDTA tubes, and 50 capillary blood samples obtained by finger stick were analyzed with QBC STAR™, Sysmex XN-module, and OM. Data were compared with Passing-Bablok regression and Bland-Altman plots. RESULTS: The Passing-Bablok regression analysis (QBC STAR™ capillary sample vs XN-module) yielded slopes comprised between 0.30 and 1.37, while the intercepts ranged between -17.57 and 232.6. Bland-Altman plots yielded relative bias comprised between -4.87% (for MN QBC STAR™ capillary sample vs XN-module) and 27% (PLT QBC STAR™ capillary sample vs XN-module). A significant bias was found for all parameters except MN and WBC, RBC in all and pediatric samples, and HB in adults samples. CONCLUSION: The results of this analytical evaluation suggest that QBC STAR™ may not be the ideal tool for performing complete blood count analysis for diagnostic purposes, while it could be more useful in urgent/emergent conditions, such as for rapid monitoring of some hematological parameters (eg, WBC and HB).


Assuntos
Contagem de Células Sanguíneas/métodos , Testes Imediatos , Adolescente , Adulto , Contagem de Células Sanguíneas/instrumentação , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Laboratórios , Masculino , Microscopia , Pessoa de Meia-Idade , Dados Preliminares , Análise de Regressão
11.
Int J Lab Hematol ; 43(4): 623-631, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33389827

RESUMO

INTRODUCTION: UniCel DxH900 (Beckman Coulter, Miami, Florida, USA) is a quantitative, multi-parameter, automated hematology analyzer for in vitro diagnostic use in clinical laboratories. The aim of this study was to evaluate the analytical performance of the new DxH900 analyzer to verify its diagnostic and clinical utility in the hematology laboratory of a tertiary care hospital in Spain. The most important and novel feature offered by DxH900 analyzer is providing MDW (monocyte distribution width), a new hematologic parameter which is being clinically validated as an early sepsis indicator with promising results. METHODS: We evaluated imprecision (including MDW), linearity, and carryover of DxH900. Method comparison for cell blood count (CBC) was performed in relation to DxH800 with 100 samples. We compared leukocyte differential (DIFF) from DxH900 with manual 400-cell differential. 390 samples were assessed for flag performance. RESULTS: Results obtained for between days and within-run imprecision were good. DxH900 showed excellent linearity (R = 1.00) over analytical range for white blood cells, red blood cells, hemoglobin, platelets, and reticulocyte count (RET) (R = 0.96) and no significant carryover effect. CBC and RET on the DxH900 correlated well with DxH800 (R ≥ 0.99). Comparison with manual differential showed excellent correlation (R ≥ 0.88), except for basophils. Flagging performance exhibited sensitivity over 90% for majority of alarm messages and very high negative predictive value (over 95%). CONCLUSION: UniCel DxH900 Coulter analyzer provides reliable results and fully comparable to DxH800. DxH900 is an accurate, highly precise analyzer with good analytical performances to be used effectively in high-volume laboratories.


Assuntos
Contagem de Células Sanguíneas/instrumentação , Feminino , Humanos , Masculino
12.
J Zoo Wildl Med ; 52(4): 1247-1256, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34998296

RESUMO

Diagnostic hematology can prove challenging to the exotic animal practitioner presented with a nonhuman primate patient. Few point-of-care automated cell counters are calibrated for primate samples. Twenty-one samples from 17 nonhuman primates presented to an exotic animal practice were analyzed. Samples were run on both canine and feline settings on each of two veterinary point-of-care analyzers: one that assays by impedance technology, and one that assays by laser flow cytometry. Samples were also sent to a reference laboratory to be assayed on an analyzer that performs simultaneous impedance and laser measurements of blood cells and has been calibrated for use in nonhuman primates. Fourteen analytes were assessed for each sample on each machine. Manual hematocrits and total white blood cell counts were also performed on 16 of the samples. Statistical analysis indicated some variance between individual parameters, but overall correlation was acceptable.


Assuntos
Contagem de Células Sanguíneas/instrumentação , Contagem de Leucócitos/instrumentação , Primatas , Animais , Contagem de Células Sanguíneas/veterinária , Testes Hematológicos/métodos , Testes Hematológicos/veterinária , Contagem de Leucócitos/veterinária , Reprodutibilidade dos Testes
13.
Int J Lab Hematol ; 43(1): 52-60, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32894640

RESUMO

BACKGROUND: Hematological patients, receiving intensive chemotherapy (predominantly acute leukemia patients), have repeated postchemotherapy periods with severe bone marrow suppression. As a result, these patients require regular monitoring of the complete blood counts (CBC) for optimal patient care. To reduce the strain on the patient, there is a need for a point-of-care (POC) hematology device that provides rapid and reliable results both in general and in cytopenic samples and is suitable for outpatient clinics. We evaluated the HemoScreen device for the most used CBC parameter both overall and at the lower range. METHODS: The HemoScreen was compared with the Sysmex XN-9000 in 206 routine venous samples and 79 capillary bedside samples focusing on white blood cells (WBC), absolute neutrophil count (ANC), red blood cells (RBC), PLT and HGB. RESULTS: The HemoScreen was less precise compared to the acceptance criteria set for larger and more advanced hematology instrument with a CV% 3.0-3.7 for WBCs, 3.6-8.4 for ANCs, 1.1-1.5 for RBCs, 2.5-4.4 for PLTs, and 1.7-2.3 for HGB. Correlation coefficient for all five parameters for the entire range was r >.95 and r >.90 at lower range for venous and capillary samples. Bias limits were within the CTCAE acceptance limits. CONCLUSIONS: The HemoScreen provides rapid and accurate test results, for evaluation of WBC, PLT, and HGB, as well as at low concentrations for guiding transfusions and postchemotherapy treatment. The device is easy to operate and can measure both venous and capillary samples. Therefore, the HemoScreen is well suited for smaller outpatient clinics and potentially home use.


Assuntos
Contagem de Células Sanguíneas/instrumentação , Leucemia/sangue , Sistemas Automatizados de Assistência Junto ao Leito , Doença Aguda , Humanos
14.
Int J Lab Hematol ; 43(3): 395-402, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33270987

RESUMO

BACKGROUND: The Mindray BC-6200 is a new automatic hematology analyzer that quantifies the parameters of blood morphology and leukocyte differential in five populations (5-Diff). The aim of the study was to evaluate the BC-6200 and compare it with the Siemens ADVIA 2120i analyzer. MATERIALS AND METHODS: The comparison between BC-6200 and ADVIA 2120i analyzers was performed using 390 whole blood samples collected on K3 EDTA. For the BC-6200, the carryover effect, precision, and linearity were evaluated. 138 samples were used to assess the sensitivity and flag ability, suggesting the presence of abnormal cells such as blasts, immature granulocytes, or atypical lymphocytes. Flagging results were compared with microscopic evaluation of blood smears. RESULTS: The BC-6200 analyzer showed a high correlation (r ≥ .97) with ADVIA 2120i for most of the compared parameters except RDW (r = .8350), MPV (r = .7634), Mon# (r = .8366), Baso# (r = .9205), and NRBC (r = .3768). The BC-6200 had better correlation with microscopic evaluation for NRBC (r = .8902) compared with ADVIA 2120i (r = .5677). The BC-6200 has shown high efficiency for flagging blasts (80.4%), immature granulocytes (80.5%), and atypical lymphocytes (69.0%). CONCLUSION: The new Mindray BC-6200 hematology analyzer provides high measurements precision and good correlation with ADVIA 2120i for most of the morphology and 5-diff parameters.


Assuntos
Contagem de Células Sanguíneas/instrumentação , Contagem de Células Sanguíneas/métodos , Hematologia/instrumentação , Hematologia/métodos , Humanos , Contagem de Leucócitos/instrumentação , Contagem de Leucócitos/métodos , Leucócitos/citologia , Reprodutibilidade dos Testes
15.
Int J Lab Hematol ; 43(3): 364-371, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33174358

RESUMO

INTRODUCTION: In the hub and spoke laboratory network, the number of hematology analyzers (HAs) within each core center has increased, and the control of HAs alignment is becoming necessary requirement to ensure analytical quality. In this scenario, HA alignment can be assessed by analyzing the same control material used for internal quality control on multiple HAs, assuming its commutability. The aim of the study was to verify the applicability of a protocol for the alignment of HAs based on control material rather than on fresh whole-blood samples. METHODS: The alignment of five HAs was evaluated for red (RBC, Hb, MCV, RET), white (WBC, NE, LY, MO, EO, BA, IG), and platelet (PLT) series parameters, following a protocol by SIBioC, using human sample (HS) and quality control material (QC), after the verification of commutability, according to the IFCC protocol. Maximum bias was derived from biological variation data. RESULTS: A complete alignment between instruments was confirmed for the majority of the parameters investigated both for HS and QC material. Partial misalignments or inconcludent results were instead evident for MCV, MO, EO, BA, and IG. Interestingly, QC material was found to be not commutable for LY, MO, and BA. CONCLUSION: The alignment of hematologic analyzers for main cell population parameters may be verified with both QC and HS, displaying consistent results and interpretation. The evaluation for some white series parameters (EO, BA, and IG) is critical, and particular attention must be paid to the values of the material used for the alignment.


Assuntos
Testes Hematológicos/normas , Contagem de Células Sanguíneas/instrumentação , Contagem de Células Sanguíneas/métodos , Contagem de Células Sanguíneas/normas , Células Sanguíneas/citologia , Índices de Eritrócitos/imunologia , Testes Hematológicos/instrumentação , Testes Hematológicos/métodos , Hematologia/instrumentação , Hematologia/métodos , Hematologia/normas , Humanos , Testes de Função Plaquetária/instrumentação , Testes de Função Plaquetária/métodos , Testes de Função Plaquetária/normas , Controle de Qualidade
16.
Transfusion ; 61(2): 568-578, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33202065

RESUMO

BACKGROUND: Manufacture of platelet concentrates (PCs) and plasma may fail to remove all residual red blood cells (rRBCs). Measuring rRBCs for compliance to guidelines has proven challenging, leading to an absence of a consensus methodology. Sysmex hematology analyzers with the Blood Bank mode (BB mode) analysis option offer the potential for automated rRBC counting. We therefore performed a two-site appraisal of the system. STUDY DESIGN AND METHODS: Performance characteristics were determined using platelet and plasma samples spiked with RBCs. Sample stability (n = 47) and the impact of sample type were also assessed. Components (platelets, n = 1474; plasma, n = 77) prepared using different routine manufacturing methods were tested to assess variation in rRBC concentration. RESULTS: Linearity studies up to 19 000 RBCs/µL demonstrated good correlation between expected and observed results (R2 ≥ 0.9731), and flow cytometric results also correlated well with BB mode (R2 = 0.9400). Precision analysis gave a limit of quantitation of 6 to 7 RBCs/µL, and carryover was 0.03%. Ethylenediaminetetraacetic acid and plain tube results were not significantly different (P ≥ 0.10), and samples were stable up to 24 hours. Apheresis PCs produced at two sites had lower rRBC concentrations (medians, 17 and 13 RBCs/µL) than those produced with the buffy coat method either manually (median, 681 RBCs/µL) or with the automated Terumo Automated Centrifuge and Separator Integration process (median, 81 RBCs/µL). All PCs failing visual inspection as having RBCs ≥4000 RBCs/µL were also detected by the BB mode. CONCLUSION: The BB mode had acceptable performance characteristics and has the potential for integration into a fully automated process control system for rRBC enumeration in plasma and PCs.


Assuntos
Contagem de Células Sanguíneas/instrumentação , Transfusão de Componentes Sanguíneos , Contagem de Eritrócitos/métodos , Eritrócitos , Anticoagulantes , Automação , Buffy Coat/citologia , Remoção de Componentes Sanguíneos/métodos , Ácido Edético , Citometria de Fluxo/instrumentação , Citometria de Fluxo/métodos , Humanos
18.
Elife ; 92020 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-33241996

RESUMO

COVID-19 induces haemocytometric changes. Complete blood count changes, including new cell activation parameters, from 982 confirmed COVID-19 adult patients from 11 European hospitals were retrospectively analysed for distinctive patterns based on age, gender, clinical severity, symptom duration, and hospital days. The observed haemocytometric patterns formed the basis to develop a multi-haemocytometric-parameter prognostic score to predict, during the first three days after presentation, which patients will recover without ventilation or deteriorate within a two-week timeframe, needing intensive care or with fatal outcome. The prognostic score, with ROC curve AUC at baseline of 0.753 (95% CI 0.723-0.781) increasing to 0.875 (95% CI 0.806-0.926) on day 3, was superior to any individual parameter at distinguishing between clinical severity. Findings were confirmed in a validation cohort. Aim is that the score and haemocytometry results are simultaneously provided by analyser software, enabling wide applicability of the score as haemocytometry is commonly requested in COVID-19 patients.


Assuntos
Contagem de Células Sanguíneas/estatística & dados numéricos , COVID-19/sangue , Hospitalização/estatística & dados numéricos , Hospitais , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Contagem de Células Sanguíneas/instrumentação , Contagem de Células Sanguíneas/métodos , COVID-19/epidemiologia , COVID-19/virologia , Estudos de Coortes , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pandemias , Prognóstico , Estudos Retrospectivos , SARS-CoV-2/fisiologia , Adulto Jovem
19.
Int J Lab Hematol ; 42(6): 705-717, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32881316

RESUMO

BACKGROUND: In Ghana, diagnostic laboratories rely on reference intervals (RIs) provided by manufacturers of laboratory analyzers which may not be appropriate. This study aimed to establish RIs for hematological parameters in adult Ghanaian population. METHODS: This cross-sectional study recruited 501 apparently healthy adults from two major urban areas in Ghana based on the protocol by IFCC Committee for Reference Intervals and Decision Limits. Whole blood was tested for complete blood count (CBC) by Sysmex XN-1000 analyzer, sera were tested for iron and ferritin by Beckman-Coulter/AU480, for transferrin, vitamin-B12, and folate was measured by Centaur-XP/Siemen. Partitioning of reference values by sex and age was guided by "effect size" of between-subgroup differences defined as standard deviation ratio (SDR) based on ANOVA. RIs were derived using parametric method with application of latent abnormal values exclusion method (LAVE), a multifaceted method of detecting subjects with abnormal results in related parameters. RESULTS: Using SDR ≥ 0.4 as a threshold, RIs were partitioned by sex for platelet, erythrocyte parameters except mean corpuscular constants, and iron markers. Application of LAVE had prominent effect on RIs for majority of erythrocyte and iron parameters. Global comparison of Ghanaian RIs revealed lower-side shift of RIs for leukocyte and neutrophil counts, female hemoglobin and male platelet count, especially compared to non-African countries. CONCLUSION: The LAVE effect on many hematological RIs indicates the need for deliberate secondary exclusion for proper derivation of RIs. Obvious differences in Ghanaian RIs compared to other countries underscore the importance of country-specific RIs for improved clinical decision-making.


Assuntos
Anemia/sangue , Adolescente , Adulto , Idoso , Contagem de Células Sanguíneas/instrumentação , Contagem de Células Sanguíneas/normas , Estudos Transversais , Índices de Eritrócitos , Feminino , Gana , Humanos , Inflamação/sangue , Ferro/sangue , Masculino , Pessoa de Meia-Idade , Valores de Referência
20.
Int J Lab Hematol ; 42(5): 533-543, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32790150

RESUMO

INTRODUCTION: Clinical reference intervals represent the normal range of clinical parameters for distinguishing healthy and sick individuals, and they show some variation among different populations. Many reference intervals are still lacking for the pediatric population in China. Thus, the aim of this study was to establish and validate pediatric reference intervals for capillary blood cell counts. METHODS: A total of 9942 children were enrolled from 10 medical institutions in Beijing, China, for capillary complete blood count (CCBC) values according to the EP28-A3c guideline issued by the Clinical and Laboratory Standards Institute. RESULTS: Pediatric reference intervals for 17 CCBC parameters were established for children aged 6 months to 7 years. The red blood cell count and red blood cell distribution width were generally higher in males than in females, and the mean corpuscular hemoglobin and mean corpuscular volume were higher in females than in males. The red blood cell, hemoglobin, hematocrit, and neutrophil percentages increased while the percentage of lymphocytes decreased with age. The overall trends for each reference interval were relatively similar in different ethnic groups and regions in the world, but with variation in the upper and lower limits, which confirms the existence of racial and geographical differences. Further validation with 508 healthy subjects showed that the verified proportions were within 90.9%-100% of the reference intervals. CONCLUSIONS: This study offers local reference intervals for CCBC values for the pediatric population in Beijing, China, and thus provides basic criteria for the diagnosis, treatment, and health assessment of childhood diseases in China.


Assuntos
Contagem de Células Sanguíneas/métodos , Valores de Referência , Fatores Etários , Pequim , Contagem de Células Sanguíneas/instrumentação , Contagem de Células Sanguíneas/normas , Criança , Pré-Escolar , Feminino , Voluntários Saudáveis , Hematócrito , Humanos , Lactente , Masculino