Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.324
Filtrar
3.
BMC Ophthalmol ; 24(1): 80, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38383362

RESUMO

PURPOSE: To compare the efficacy and efficiency of self-assembled intraocular rare earth magnet and forceps in removing intraocular foreign bodies(IOFBs) undergoing 25-gauge(G) pars plana vitrectomy. METHODS: A total of 30 patients with metallic IOFB underwent 25-G PPV were enrolled into this study. Self-assembled intraocular rare earth magnet were used in 15 patients(bar group), and forceps were used in 15 patients(forceps group). Success rate of removing IOFB, time taken to remove IOFB, incidence of IOFB slippage and fall, iatrogenic retinal damages were compared between the two groups. RESULTS: There was no significant difference in success rate of removing IOFBs between the groups(93.3% and 100%, P > 0.99). The median time taken of removing FB was significantly shorter in bar group than in forceps group(112 and 295 s, P = 0.001). None of the patients in bar group had IOFB slippage and fall, or related iatrogenic retinal damage in the process of removal. In forceps group, IOFB slippage and fall during removal were observed in 7 of 15(47.6%) patients, related iatrogenic retinal injuries were recorded in 6 of 15(40.0%) patients, both were significantly higher than bar group(P = 0.003 and P = 0.017, respectively). CONCLUSIONS: Compared with forceps, the assembled intraocular magnet can greatly reduce the possibility of IOFB slippage and fall, prevent related iatrogenic retinal damage, and shorten the time taken to remove IOFB. The assembled intraocular magnet can be an useful tool in removing metallic IOFBs in PPV.


Assuntos
Corpos Estranhos no Olho , Ferimentos Oculares Penetrantes , Doenças Retinianas , Humanos , Vitrectomia , Imãs , Estudos Retrospectivos , Corpos Estranhos no Olho/etiologia , Corpos Estranhos no Olho/cirurgia , Instrumentos Cirúrgicos , Doenças Retinianas/cirurgia , Doença Iatrogênica , Ferimentos Oculares Penetrantes/etiologia , Ferimentos Oculares Penetrantes/cirurgia
4.
Curr Probl Diagn Radiol ; 53(3): 369-371, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38290902

RESUMO

OBJECTIVE: The purpose of this research is to more precisely quantify the positivity rate for conventional radiographs (CR) of the orbit performed for the purpose of pre-MR screening in patients at risk of having a radio-opaque orbital foreign body (ROFB). METHODS: By review of electronic medical records, we identified 47,237 patients who had undergone orbital CR for clearance of ROFB prior to MRI. The reports from these examinations were manually reviewed, and the examinations with positive findings were re-interpreted by a CAQ-certified head and neck radiologist. The rate of ROFB found in these examinations was reported and compared to historical estimates in the literature. RESULTS: 328 of the 47,237 examinations (0.69 %) were originally interpreted as positive for ROFB. Upon re-review, only 39 of the 47,237 examinations (0.083 %, 95 % CI 0.06 %-0.11 %) contained ROFB that were in locations that posed a risk to ocular or vascular structures or were in an equivocal location. Almost all of the patients with false-positive initial interpretations had been denied MRI. DISCUSSION: The rate of ROFB discovered on clearance CR of the orbits prior to MRI is far less than previously estimated in the radiology literature. More conservative guidelines for MR clearance may be useful to reduce costs, mitigate imaging delays, and avoid unnecessary denial of imaging.


Assuntos
Corpos Estranhos no Olho , Doenças Orbitárias , Humanos , Corpos Estranhos no Olho/diagnóstico por imagem , Corpos Estranhos no Olho/etiologia , Metais , Radiografia , Imageamento por Ressonância Magnética , Órbita/diagnóstico por imagem
5.
Retina ; 44(6): 1107-1110, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38176001

RESUMO

PURPOSE: The intraocular lens blocking technique described for the removal of intraocular foreign bodies emerged as a result of an effort to prevent the foreign body from being retracted into the posterior segment because of the resistance encountered while removing it from the corneal incision. However, in the technique described, in addition to the difficulty of the surgical procedure, the new concern is to create a posterior capsulorhexis according to the size of the foreign body and to pass the foreign body through the capsulorhexis. METHODS: Here, the authors describe a new approach to the intraocular lens blocking technique. In this approach, the intraocular foreign body, which is held with intraocular forceps without any opening in the posterior capsule, is held in a perpendicular position to the long axis, lifted directly into the anterior chamber, and safely removed from the front of the monoblock foldable intraocular lens. RESULTS: In all patients treated with this approach, IOFBs were successfully removed without intraoperative or postoperative complications, and postoperative intraocular lens centralization was achieved in all patients. CONCLUSION: This approach may provide practicality to the intraocular lens blocking technique.


Assuntos
Capsulorrexe , Corpos Estranhos no Olho , Lentes Intraoculares , Humanos , Corpos Estranhos no Olho/cirurgia , Corpos Estranhos no Olho/diagnóstico , Capsulorrexe/métodos , Masculino , Feminino , Adulto , Ferimentos Oculares Penetrantes/cirurgia , Pessoa de Meia-Idade , Adulto Jovem
6.
Am J Trop Med Hyg ; 110(3): 618-621, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38266302

RESUMO

Caterpillars can damage human health, including visual acuity, as a result of penetration of the setae into the eye or their layout on the eye tissue. However, the path of setae movement in the eye remains unclear. In this study, a 43-year-old woman was injured in the left eye by a caterpillar. Other than rubbing her eye, the patient did not attempt any type of treatment, and she visited our outpatient clinic 5 days after the accident. The patient's left eyelid was markedly swollen, with a visual acuity of 1.0 in the right eye and only 0.04 in the left eye. Images of the setae in the eye were taken using an oil lens microscope, which showed clearly their detailed characteristics. The setae were removed from the eye as much as possible. Topical eyedrops and oral steroids were used to reduce the inflammation. Vitritis and retinitis occurred at the 6-month follow-up and was classified as ophthalmia nodosa by the ophthalmologist. Before we did our study, some ophthalmologists believed that setae moved forward; however, we found that setae in the eye moved in a disorderly fashion. We also note that all setae should be removed. This case demonstrates that caterpillar setae in the eye move in a disorderly fashion and eventually caused ophthalmia nodosa.


Assuntos
Endoftalmite , Corpos Estranhos no Olho , Ceratoconjuntivite , Lepidópteros , Humanos , Animais , Feminino , Adulto , Sensilas , Corpos Estranhos no Olho/complicações , Corpos Estranhos no Olho/diagnóstico , Endoftalmite/complicações
7.
Semin Ophthalmol ; 39(2): 139-142, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38069614

RESUMO

The standard of care for open globe injuries is prompt surgical closure, as delay in repair is a reported risk factor for post-traumatic endophthalmitis and is associated with worse visual outcomes. This article serves as a review of the current management and outcomes of open globe injuries repaired greater than 24 hours from the time of injury, specifically evaluating the rates of endophthalmitis in cases with and without intraocular foreign bodies, visual outcomes and rates of primary enucleation or evisceration.


Assuntos
Endoftalmite , Corpos Estranhos no Olho , Ferimentos Oculares Penetrantes , Humanos , Ferimentos Oculares Penetrantes/cirurgia , Ferimentos Oculares Penetrantes/complicações , Acuidade Visual , Corpos Estranhos no Olho/cirurgia , Endoftalmite/etiologia , Fatores de Risco , Estudos Retrospectivos
9.
Eye (Lond) ; 38(2): 297-302, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37532833

RESUMO

AIM: To report the clinical settings and factors predicting outcomes in scleral tears with concurrent retained intraocular foreign bodies METHODS: All cases with scleral and corneoscleral wounds with retained intraocular foreign bodies (RIOFB) from January 2014 to January 2021 were retrospectively analysed. Favourable anatomic outcome was defined as presence of globe integrity, attached retina, absence of hypotony and active inflammation at last visit. Favourable functional outcome was defined as final visual acuity (VA) > 20/200. RESULTS: Total 139 eyes were included. Mean age was 30.66 ± 13.32 years (median 29 years, IQR 17). Penetrating trauma accounted for 87.1%, rupture for 5.8%, perforation for 7.2%. In 5.8% of the eyes the injury involved zone I extending till Zone II while in 66.9% it involved Zone II and in 27.3% in Zone III. Snellen visual acuity at presentation was logMAR 2.97 ± 1.01 and at last visit was logMAR 2.38 ± 1.45 (p < 0.0001). Time between presentation and repair was 13.93 ± 19.56 h (median 7.6 h, IQR 17.17). Favourable functional outcome was seen in 34.5% eyes and 2/3rd achieved favourable anatomic outcome. Absence of endophthalmitis (OR = 6.25, p = 0.003) and ability to remove the foreign body (OR = 7.05, p = 0.003) were associated with a favourable anatomic outcome. Better presenting Snellen visual acuity (OR = 2.77, p = 0.003), manifest scleral tear (OR = 3.36, p = 0.04), and absence of endophthalmitis (OR = 50, p = 0.0009) were associated with a favourable functional outcome. CONCLUSION: A third of the cases achieved favourable visual outcome while 2/3rd achieved favourable anatomic outcome. Absence of endophthalmitis is an important factor predicting both.


Assuntos
Endoftalmite , Corpos Estranhos no Olho , Ferimentos Oculares Penetrantes , Humanos , Adolescente , Adulto Jovem , Adulto , Vitrectomia , Estudos Retrospectivos , Ferimentos Oculares Penetrantes/diagnóstico , Ferimentos Oculares Penetrantes/cirurgia , Ferimentos Oculares Penetrantes/complicações , Endoftalmite/diagnóstico , Endoftalmite/terapia , Endoftalmite/complicações , Corpos Estranhos no Olho/diagnóstico , Corpos Estranhos no Olho/cirurgia , Corpos Estranhos no Olho/complicações
10.
Eur J Ophthalmol ; 34(2): NP92-NP97, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37723890

RESUMO

INTRODUCTION: Panuveitis is a serious inflammatory disease. Setae are fibers produced by many insects and plants. Many case reports have described caterpillar and spider fibers entering the eye. These hairs are covered with tiny barbs that help them enter and migrate into the eye tissue, leading to severe inflammation. Normally, they are buried mainly in the conjunctiva and cornea. However, in the present case, they entered the posterior segment of the eye, which is very rare. CASE DESCRIPTION: A female patient presented with a complaint of repeated foreign body sensation, redness, pain, and photophobia in the left eye for 9 years following initial exposure to caterpillars. She visited the doctor in January after aggravation of symptoms. Slit-lamp examination, ultrasound biomicroscopy, ultrasound B-scan, fluorescein angiography, and indocyanine green angiography revealed the presence of a foreign body in the vitreous, which caused discomfort in the patient's left eye and subsequently, panuveitis of the left eye. The symptoms improved significantly after foreign body removal using vitrectomy. Microscopic examination revealed that the foreign body was caterpillar setae. CONCLUSION: Clinicians should be more vigilant about history of contact with caterpillars while examining uveitis that has recurred for many years. Identification of the root cause of the disease can ensure better treatment.


Assuntos
Corpos Estranhos no Olho , Lepidópteros , Pan-Uveíte , Uveíte , Animais , Feminino , Humanos , Sensilas , Corpos Estranhos no Olho/diagnóstico , Corpos Estranhos no Olho/etiologia , Corpos Estranhos no Olho/cirurgia , Pan-Uveíte/diagnóstico , Pan-Uveíte/etiologia , Uveíte/complicações , Córnea
11.
Ophthalmologie ; 121(1): 36-42, 2024 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-37733261

RESUMO

BACKGROUND: A novel method for trapping voles is the use of pistol-like explosive tools loaded with bolt-action ammunition. When triggered the vole is killed by the very high gas pressure created. Accidental releases can result in facial and/or eye injuries. The aim of this work was to describe the injury pattern in the patient and to experimentally verify whether there is a risk of penetrating eye injuries. METHODS: Two emergency patients presented to our eye clinic with eye injuries after unintentional triggering of the explosive trap. Based on the new pattern of injury noted, experiments were performed on enucleated porcine eyes to determine the possible severity. For this purpose, a vole trap was clamped in a holder and loaded with a Cal. 9â€¯× 17 mm cartridge in each case. In front of the muzzle opening, 3 pig eyes each were fixed on Styrofoam at a distance of 20, 40, 60 and 80 cm. The foreign body indentations in the cornea were visualized and measured by spectral domain optical coherence tomography (SD-OCT). The pig eyes were then dissected and searched for foreign bodies using microscopy. The SD-OCT images of an injured patient were also included for human comparison. RESULTS: On patient examination, in addition to the usual fine gunshot marks on the face and conjunctiva/eye area, wax-like, larger and heavier particles of approximately 0.1-0.2 mm in size were found, which originated from the cartridge end cap. Removal of these foreign bodies, some of which were injected more deeply into the cornea, conjunctiva, and tenon, is much more difficult and extensive than in usual blast trauma. There was no evidence of intraocular foreign bodies in either patient. Likewise, no intraocular foreign bodies could be detected experimentally in any pig eyeball (n = 12). Remnants of the wax-like cartridge end were found deeply penetrating into the corneal stroma. The maximum penetration depth measured against the total corneal thickness was 46% at 20 cm device distance and decreased with greater distance to the vole trap (penetration depth at 40 cm at 37%, at 60 cm at 28% and at 80 cm at 19%). For comparisons on the human eye, a penetration depth of 54% was measured at a distance of about 40 cm. In pig eyes the number of foreign bodies per cm2 decreased with increasing distance from the vole trap (mean: n = 174 foreign bodies, FB, at 20 cm distance, n = 46 FB at 40 cm, n = 23 FB at 60 cm, and n = 9 FB at 80 cm). The largest penetrating foreign bodies measured a mean of 383 ± 43 µm with a maximum of 451 µm. CONCLUSION: New vole traps with gas-powered mechanisms result in larger deeply penetrating wax-like foreign bodies in the cornea, conjunctiva, and tenon of the eye, which are difficult to remove and only surgically possible. Despite the significant explosion during triggering, there was no evidence of penetrating ocular injury from the foreign bodies either in the patient or experimentally in the pig eyes. Safety goggles should be worn when handling the traps to avoid penetration of foreign bodies into the eye.


Assuntos
Corpos Estranhos no Olho , Ferimentos Oculares Penetrantes , Ferimentos Penetrantes , Humanos , Animais , Suínos , Corpos Estranhos no Olho/diagnóstico , Córnea , Ferimentos Oculares Penetrantes/diagnóstico , Face , Tomografia de Coerência Óptica
12.
Eur J Ophthalmol ; 34(2): NP98-NP100, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37649334

RESUMO

PURPOSE: To report a rare case of a 65 year old patient with a single caterpillar hair with localised lenticular opacity around it and no active inflammation. OBSERVATIONS: A single quiescent caterpillar hair embedded in the anterior lens capsule causing localised cataract around it. There was no other sign of ocular toxicosis and the patient was unaware of the presence of this intraocular foreign body. CONCLUSIONS: Caterpillar hair (also known as setae) are a common cause of ophthalmia nodosa. These setae can penetrate intraocularly with ease to cause various forms of ocular toxicosis ranging from conjunctivitis, keratitis, pars planitis, chorioretinitis to even severe vitritis warranting enucleation. As per our knowledge and experience, no case of caterpillar hair without inflammation has been reported till date. We hereby report a rare case of a 65 year old patient with a single caterpillar hair embedded in the anterior lens capsule causing localised cataract around it without any active inflammation. In our opinion, if the eye is quiescent, the patient should be kept on close and long term follow-up and active intervention can be undertaken at the first instance of inflammation or if cataract progresses.


Assuntos
Catarata , Corpos Estranhos no Olho , Lepidópteros , Animais , Humanos , Idoso , Corpos Estranhos no Olho/complicações , Corpos Estranhos no Olho/diagnóstico , Corpos Estranhos no Olho/cirurgia , Catarata/etiologia , Catarata/complicações , Cabelo , Inflamação
13.
Med Phys ; 51(4): 3124-3129, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38055556

RESUMO

BACKGROUND: Ocular foreign bodies (OFBs) are a relatively common occurrence in ocular injuries, and a severe risk factor for vision disorders. They are notoriously challenging to identify and localize precisely to allow surgical removal, even with the most recent technological advancements. PURPOSE: To compare the efficiency of different imaging methods in detecting and localizing OFBs. METHODS: We conducted a retrospective analysis of the medical records of patients with OFBs, detected by ultrasound biomicroscopy (UBM) and confirmed during surgery. Patients who presented to our medical center between January 2016 and January 2022 and also underwent computed tomography (CT), X ray, and/or ocular B-scan ultrasonography (B-scans) were selected. RESULTS: This study included 134 patients with a history of ocular trauma and OFBs (mean age: 47.25 years, range: 8-78). The mean time interval from injury to UBM examination was 36.31 months (range: 0.2-120 months). Most OFBs were metallic (51.82%) or plant-based (25.37%); 22.39% of them were located in the sclera, 26.87% in the anterior chamber, and 23.88% in the ciliary body and iris. OFBs ranged in size from 0.10 to 6.67 mm (mean: 1.15 ± 1.10 mm). B-scans identified OFBs in 37 of the 119 patients examined (31.09%); CT in 52 of 84 patients (61.90%); and radiography in 29 of 50 patients (58.00%). Univariate and multivariate analyses determined that both CT and radiography showed low detection rates for plant-based versus non-plant-based OFBs (CT: p < 0.001; radiography: p = 0.007), small particles (<1.00 mm vs. >1.00 mm; CT: p = 0.001, radiography: p = 0.024), and with eyeball wall locations (vs. intraocular; CT: p < 0.001, radiography: p = 0.021). Similarly, B-scans were less efficient for plant-based and eyeball wall-located OFBs (both p = 0.001), whereas the difference based on dimensions was not significant (p = 0.118). CONCLUSIONS: CT, radiography, and B-scans showed lower detection rates for plant-based, small, and eyeball wall-located OFBs. Our findings strongly suggest that UBM could be a more adequate imaging modality when such OFBs are suspected.


Assuntos
Corpos Estranhos no Olho , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Corpos Estranhos no Olho/diagnóstico por imagem , Corpos Estranhos no Olho/etiologia , Corpos Estranhos no Olho/cirurgia , Microscopia Acústica , Ultrassonografia , Radiografia
14.
Eye (Lond) ; 38(7): 1355-1361, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38160215

RESUMO

OBJECTIVES: To identify the clinical features and outcomes of early vitrectomy in patients with open globe injury (OGI) and the prognostic factors for visual outcome. METHODS: This retrospective observational case series included 390 eyes in 389 patients diagnosed with OGI receiving vitrectomy within four days after injury. Preoperative parameters included the injury types, wound locations, consequent tissue damages, initial visual acuity (VA), and ocular trauma score. Postoperative outcome measures included surgical procedures, retinal (re)attachment, complications, and final VA. The logistic analysis evaluated the prognostic factors for visual outcome. RESULTS: Intraocular foreign bodies (59.2%) and penetrating injuries (28.7%) were the most common injury types. Among the 165 eyes with retinal detachment (RD), 121 (73.3%) had retinal reattachment during early primary vitrectomy, and 32 (19.4%) were repaired during a second or subsequent surgery. Thirteen eyes (3.3%) were enucleated. The final VA improved from the initial level in 207 eyes (55.2%), remained unchanged in 123 (32.8%), and decreased in 45 (12.0%). Multivariable regression revealed that the injury zone, initial VA, RD, and endophthalmitis were associated with poor visual outcomes (P < 0.05). CONCLUSIONS: Higher zone injury, low initial VA, RD, and endophthalmitis are predictors of poor visual outcome in eyes undergoing early vitrectomy for OGI.


Assuntos
Ferimentos Oculares Penetrantes , Acuidade Visual , Vitrectomia , Humanos , Vitrectomia/métodos , Estudos Retrospectivos , Acuidade Visual/fisiologia , Masculino , Feminino , Ferimentos Oculares Penetrantes/cirurgia , Ferimentos Oculares Penetrantes/fisiopatologia , Ferimentos Oculares Penetrantes/diagnóstico , Adulto , Pessoa de Meia-Idade , Prognóstico , Adolescente , Adulto Jovem , Criança , Idoso , Corpos Estranhos no Olho/cirurgia , Corpos Estranhos no Olho/fisiopatologia , Corpos Estranhos no Olho/diagnóstico , Descolamento Retiniano/cirurgia , Descolamento Retiniano/fisiopatologia , Pré-Escolar , Lactente
15.
Retin Cases Brief Rep ; 18(1): 29-31, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-35921626

RESUMO

PURPOSE: We report a novel method of intraoperative localization of a retained anterior intraocular foreign body (IOFB), using a combination of ultrasound biomicrosopy and an insulated needle. METHODS: A retrospective case report of a 56-year-old man who presented with a right eye IOFB. RESULTS: On presentation, vision was decreased in the right eye to count fingers with a small subconjunctival hemorrhage, but no other signs of a penetrating laceration. Orbital CT revealed an IOFB, and the initial vitrectomy failed to retrieve the IOFB. Then, during the subsequent vitrectomy, using an ultrasound compatible needle and an ultrasound biomicrosopy, we were able to precisely locate and remove the small anterior IOFB. CONCLUSION: Retained IOFBs can lead to severe irreversible vision loss if not promptly removed. Ancillary imaging modalities and localization techniques can help locate occult IOFBs in difficult cases.


Assuntos
Corpos Estranhos no Olho , Ferimentos Oculares Penetrantes , Masculino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Microscopia Acústica , Ferimentos Oculares Penetrantes/diagnóstico por imagem , Ferimentos Oculares Penetrantes/cirurgia , Corpos Estranhos no Olho/diagnóstico por imagem , Corpos Estranhos no Olho/cirurgia , Vitrectomia/métodos
16.
Rev. bras. oftalmol ; 83: e0002, 2024. graf
Artigo em Português | LILACS | ID: biblio-1529930

RESUMO

RESUMO O propósito deste estudo foi reportar as alterações oculares observadas após picada de abelha com ferrão retido na córnea. Destacamos o tratamento e o desfecho de uma lesão de córnea incomum e sua patogênese. Trata-se de relato de caso e revisão da literatura de lesões oculares por picada de abelha. Paciente do sexo feminino, 63 anos, procurou atendimento oftalmológico de urgência devido à picada de abelha na córnea do olho direito há 6 dias. Queixava-se de embaçamento visual, dor e hiperemia ocular. Apresentou acuidade visual de vultos no olho afetado. Ao exame, notaram-se hiperemia moderada de conjuntiva bulbar, edema corneano com dobras de Descemet e presença do ferrão alojado na região temporal, no estroma profundo da córnea. A paciente foi internada para ser abordada no centro cirúrgico sob anestesia geral. Durante a cirurgia, o ferrão teve que ser retirado via câmara anterior, mediante a realização de uma paracentese e uma lavagem da câmara anterior, com dupla via e solução salina balanceada. Ainda não existe na literatura um tratamento padrão na abordagem de pacientes com lesões oculares por picada de abelha, sendo importantes a identificação e o reconhecimento precoce de possíveis complicações que ameacem a visão.


ABSTRACT The purpose of this study was to report the ocular changes observed after a bee sting with a stinger retained in the cornea. We show the treatment and outcome of an unusual corneal injury and its pathogenesis. This is a case report and literature review of ocular injuries caused by bee stings. A 63-year-old female patient sought emergency ophthalmic care because of a bee sting on the cornea of her right eye six days before. She complained of blurred vision, pain, and ocular hyperemia. She had glare sensitivity on visual acuity in the affected eye. Examination revealed moderate hyperemia of the bulbar conjunctiva, corneal edema with Descemet's folds and a stinger lodged in the temporal region, in the deep stroma of the cornea. The patient was admitted to the operating room under general anesthesia. During surgery, the stinger had to be removed via the anterior chamber, by performing a paracentesis and washing the anterior chamber with a double flushing and balanced saline solution. There is still no standard treatment in the literature for patients with eye injuries caused by bee stings, and early identification and recognition of possible sight-threatening complications is important.


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Venenos de Abelha/efeitos adversos , Edema da Córnea/etiologia , Corpos Estranhos no Olho/complicações , Lesões da Córnea/etiologia , Mordeduras e Picadas de Insetos/complicações , Procedimentos Cirúrgicos Oftalmológicos/métodos , Edema da Córnea/diagnóstico , Edema da Córnea/fisiopatologia , Iridociclite , Corpos Estranhos no Olho/cirurgia , Corpos Estranhos no Olho/diagnóstico , Lesões da Córnea/cirurgia , Lesões da Córnea/diagnóstico , Microscopia com Lâmpada de Fenda , Gonioscopia , Mordeduras e Picadas de Insetos/cirurgia , Mordeduras e Picadas de Insetos/diagnóstico
18.
BMJ Case Rep ; 16(12)2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38081737

RESUMO

We present a case of an intracorneal wooden foreign body that remained undetected for 15 years following an ocular injury sustained during gardening. The patient presented with stable visual acuity despite the long-standing presence of a wooden splinter embedded in the cornea. Interestingly, Pentacam corneal tomography did not show any abnormalities despite the foreign body piercing through the corneal stroma and endothelium. This case may serve as an opportunity to re-examine the approach to managing chronic and stable intracorneal wooden foreign bodies and explore the implications of continued observation rather than surgical management.


Assuntos
Corpos Estranhos no Olho , Ferimentos Oculares Penetrantes , Humanos , Corpos Estranhos no Olho/diagnóstico por imagem , Corpos Estranhos no Olho/cirurgia , Achados Incidentais , Córnea/cirurgia , Substância Própria , Ferimentos Oculares Penetrantes/diagnóstico por imagem , Ferimentos Oculares Penetrantes/cirurgia
19.
Open Vet J ; 13(10): 1379-1384, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38027412

RESUMO

Background: Intra-lenticular foreign bodies are rare in veterinary medicine and uncommon in human medicine. Approximately 50% of perforating ocular injuries in canines have lenticular involvement. Treatment choices include conservative management and surgical options. Retained intra-lenticular foreign body with delayed removal has not been reported in animals. Case Description: A 3-year-old male neutered Lurcher presented with right-sided ocular discomfort and a sealed full-thickness corneal perforation. The full ophthalmic examination could not be performed at the initial presentation due to miosis. Recrudescence of anterior uveitis was seen post-drug cessation. Re-evaluation of the eye with a mydriatic pupil revealed an intra-lenticular foreign body. Surgical removal via phacoemulsification was performed 8 weeks after the initial perforating injury. The eye remains visual, comfortable, and normotensive 50 months post-operatively. Conclusion: This is the first report of an encapsulated, retained intra-lenticular foreign body with delayed removal in a dog. Mydriasis and repeat examinations are of crucial importance when evaluating eyes post-perforation.


Assuntos
Doenças do Cão , Corpos Estranhos no Olho , Cristalino , Facoemulsificação , Humanos , Masculino , Cães , Animais , Cristalino/lesões , Cristalino/cirurgia , Corpos Estranhos no Olho/diagnóstico , Corpos Estranhos no Olho/cirurgia , Corpos Estranhos no Olho/veterinária , Facoemulsificação/veterinária , Doenças do Cão/diagnóstico , Doenças do Cão/cirurgia
20.
Indian J Ophthalmol ; 71(12): 3620-3625, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37991293

RESUMO

PURPOSE: To assess clinical features, visual outcomes, and setting of mobile battery blast-induced eye injuries in children. METHODS: Retrospective case sheets of children with mobile battery blast injuries were reviewed at a tertiary eye care center from January 2015 to March 2022. We noted the mode of injury, battery status, and clinical presentation and analyzed the treatment outcomes. RESULTS: The study included 14 eyes of 11 patients. Three patients (27%) had bilateral ocular injuries. The most common reasons for the blast were wiring a bulb to the battery or charging the battery with a universal mobile charger, seen in four cases each. Three eyes had closed-globe injuries (CGIs), whereas 11 had open-globe injuries (OGIs). Of the 11 eyes with OGI, four also had a retained intraocular foreign body (IOFB). Only four (36%) eyes having OGI could achieve vision better than 6/60. All three eyes with CGIs developed secondary glaucoma, and two underwent trabeculectomy. However, the visual prognosis was better (>6/36) in eyes with CGI. Overall, mean visual acuity at the final follow-up was improved to 1.41 ± 1.14 logMAR from 2.32 ± 0.76 logMAR at presentation. This was also found to be statistically significant with a P value of 0.02. CONCLUSION: Battery blast-induced ocular injuries, although rare, often lead to poor outcomes. Apart from charging, playing with discarded or damaged batteries was a common reason for battery blasts in our series.


Assuntos
Traumatismos por Explosões , Corpos Estranhos no Olho , Ferimentos Oculares Penetrantes , Traumatismos Oculares , Humanos , Criança , Traumatismos por Explosões/diagnóstico , Traumatismos por Explosões/epidemiologia , Traumatismos por Explosões/etiologia , Estudos Retrospectivos , Traumatismos Oculares/complicações , Traumatismos Oculares/diagnóstico , Traumatismos Oculares/epidemiologia , Corpos Estranhos no Olho/diagnóstico , Corpos Estranhos no Olho/epidemiologia , Corpos Estranhos no Olho/etiologia , Acuidade Visual , Resultado do Tratamento , Prognóstico , Ferimentos Oculares Penetrantes/diagnóstico , Ferimentos Oculares Penetrantes/epidemiologia , Ferimentos Oculares Penetrantes/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...