Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Unfallchirurg ; 117(1): 80-2, 2014 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-23756787

RESUMO

The irritating effects of concrete (calcium oxide) on skin have long been known. The effect by long-term skin exposure is not only irritating but also erosive and alkali skin erosion may result due to colliquative skin necrosis. A complicated course may ensue potentially necessitating plastic reconstructive treatment due to the development of unstable scars and defects. Correct interpretation of the skin trauma and adequate treatment are mandatory for functional restitution.


Assuntos
Álcalis/intoxicação , Queimaduras Químicas/cirurgia , Materiais de Construção/efeitos adversos , Dermatite Alérgica de Contato/cirurgia , Procedimentos Cirúrgicos Dermatológicos/métodos , Traumatismos da Perna/cirurgia , Pele/lesões , Adulto , Queimaduras Químicas/diagnóstico , Queimaduras Químicas/etiologia , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/etiologia , Humanos , Traumatismos da Perna/diagnóstico , Traumatismos da Perna/etiologia , Masculino , Resultado do Tratamento
2.
J Vasc Surg ; 58(5): 1388-90, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23611713

RESUMO

We present a case of a patient who developed a systemic allergic reaction following placement of a nitnol stent in the superficial femoral artery for claudication symptoms. Shortly after, he was tested for contact dermatitis and found to have a severe reaction to nickel. His symptoms of severe itch and generalized rash resolved within days following stent explantation and reconstruction with a vein graft. The epidemiology and clinical significance of nickel allergy and the concomitant use of nickel-alloy stents are discussed.


Assuntos
Angioplastia/efeitos adversos , Dermatite Alérgica de Contato/etiologia , Artéria Femoral , Níquel/efeitos adversos , Doença Arterial Periférica/terapia , Stents/efeitos adversos , Angioplastia/instrumentação , Constrição Patológica , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/cirurgia , Remoção de Dispositivo , Humanos , Claudicação Intermitente/etiologia , Claudicação Intermitente/terapia , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/complicações , Doença Arterial Periférica/diagnóstico , Desenho de Prótese , Reoperação , Veia Safena/transplante , Resultado do Tratamento
3.
J Gynecol Obstet Biol Reprod (Paris) ; 40(2): 174-7, 2011 Apr.
Artigo em Francês | MEDLINE | ID: mdl-20888147

RESUMO

We report a case of atopic dermatitis in relation with a surgical titanium clip. Such a complication has only been reported once in the literature. We advocate to ask the patients about query atopic manifestations especially contact dermatitis to metal before any procedure involving metallic implants.


Assuntos
Mama , Dermatite Alérgica de Contato/etiologia , Doença da Mama Fibrocística/cirurgia , Instrumentos Cirúrgicos/efeitos adversos , Titânio/imunologia , Dermatite Alérgica de Contato/patologia , Dermatite Alérgica de Contato/cirurgia , Feminino , Humanos , Pessoa de Meia-Idade , Próteses e Implantes/efeitos adversos
5.
Orthopade ; 37(2): 136-42, 2008 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-18210089

RESUMO

The annual number of total knee replacement implantations is rising continuously. A progressive cutaneous hypersensitivity rate against metallic materials in the population has been registered which can lead to an increase of allergy-induced reactions associated with implant loosening in the future although the correlation with an allergic cutaneous sensitisation has not been proven in all cases. On apparent allergy against metallic implant components different alternative solutions to standard endoprostheses should be taken into account for primary implantation or revision of total knee replacement, for example the application of implant components without metallic elements (e.g. ceramics), the use of non-allergic metallic implants, such as titanium or ZrNb alloys, or potential allergy-inducing metallic materials after masking the implant surface using a suitable coating. In the case of primary or revision surgery most patients with metal allergy are treated with a Ti(Nb)N-coated knee implant made of cobalt-chrome or titanium alloys in our hospital. Within an international multi-centre study we are currently implanting a newly developed knee endoprosthesis system with a ceramic femoral component as an alternative.


Assuntos
Hipersensibilidade/etiologia , Hipersensibilidade/prevenção & controle , Prótese do Joelho/efeitos adversos , Metais/efeitos adversos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Adulto , Ligas , Cerâmica , Materiais Revestidos Biocompatíveis , Dermatite Alérgica de Contato/etiologia , Dermatite Alérgica de Contato/prevenção & controle , Dermatite Alérgica de Contato/cirurgia , Humanos , Hipersensibilidade/cirurgia , Molibdênio , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Falha de Prótese , Reoperação , Titânio , Zircônio
8.
Hautarzt ; 48(6): 410-3, 1997 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-9333618

RESUMO

A 35 year old patient developed swellings in the red colored areas of his tattoo. Histological examination revealed a lichenoid, pseudolymphomatous infiltrative pattern, that could be distinguished from frank lymphoma by means of electron microscopy, immunohistochemistry and molecular biology. The presence of dermal dendritic cells suggests a dermal-allergic pathogenesis of non-granulomatous tattoo reactions. Therapy of choice is an excision of the inflamed areas.


Assuntos
Dermatite Alérgica de Contato/etiologia , Pseudolinfoma/etiologia , Tatuagem , Adulto , Biópsia , Células Dendríticas/patologia , Dermatite Alérgica de Contato/patologia , Dermatite Alérgica de Contato/cirurgia , Diagnóstico Diferencial , Humanos , Masculino , Pseudolinfoma/patologia , Pseudolinfoma/cirurgia , Pele/patologia
10.
HNO ; 43(7): 446-9, 1995 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-7673004

RESUMO

Tracheal stenoses occur mainly under iatrogenic conditions: they develop specially after long-term intubation, but also after tracheotomy. Etiological-pathogenic relevant factors include the mechanical irritation of mucosa, perichondrium and cartilage in addition to infected tracheal secretions. An allergic cell-mediated reaction in the respiratory tract has been already described. It is seldom recognized. The possibility of such a hyperergic, allergic, delayed reaction (Type IV Coombs-Gell response) with subsequent tracheal stenosis caused by rubber chemicals (accelerators) found in endotracheal tubes is presented in the following case report.


Assuntos
Dermatite Alérgica de Contato/etiologia , Intubação Intratraqueal/instrumentação , Infarto do Miocárdio/terapia , Ressuscitação , Borracha/efeitos adversos , Estenose Traqueal/etiologia , Traqueíte/etiologia , Dermatite Alérgica de Contato/cirurgia , Humanos , Doença Iatrogênica , Assistência de Longa Duração , Masculino , Pessoa de Meia-Idade , Testes do Emplastro , Estenose Traqueal/cirurgia , Traqueíte/cirurgia , Traqueostomia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...