Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.212
Filtrar
1.
PLoS One ; 19(5): e0302967, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38722908

RESUMO

Ricin is a highly toxic protein, capable of inhibiting protein synthesis within cells, and is produced from the beans of the Ricinus communis (castor bean) plant. Numerous recent incidents involving ricin have occurred, many in the form of mailed letters resulting in both building and mail sorting facility contamination. The goal of this study was to assess the decontamination efficacy of several commercial off-the-shelf (COTS) cleaners and decontaminants (solutions of sodium hypochlorite [bleach], quaternary ammonium, sodium percarbonate, peracetic acid, and hydrogen peroxide) against a crude preparation of ricin toxin. The ricin was inoculated onto four common building materials (pine wood, drywall joint tape, countertop laminate, and industrial carpet), and the decontaminants were applied to the test coupons using a handheld sprayer. Decontamination efficacy was quantified using an in-vitro cytotoxicity assay to measure the quantity of bioactive ricin toxin extracted from test coupons as compared to the corresponding positive controls (not sprayed with decontaminant). Results showed that decontamination efficacy varied by decontaminant and substrate material, and that efficacy generally improved as the number of spray applications or contact time increased. The solutions of 0.45% peracetic acid and the 20,000-parts per million (ppm) sodium hypochlorite provided the overall best decontamination efficacy. The 0.45% peracetic acid solution achieved 97.8 to 99.8% reduction with a 30-min contact time.


Assuntos
Descontaminação , Ricina , Descontaminação/métodos , Hipoclorito de Sódio/farmacologia , Hipoclorito de Sódio/química , Materiais de Construção , Ácido Peracético/farmacologia , Ácido Peracético/química , Peróxido de Hidrogênio/química , Animais , Desinfetantes/farmacologia , Desinfetantes/química
2.
Food Res Int ; 186: 114364, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38729726

RESUMO

With the aim of reintroducing wheat grains naturally contaminated with mycotoxins into the food value chain, a decontamination strategy was developed in this study. For this purpose, in a first step, the whole wheat kernels were pre-treated using cold needle perforation. The pore size was evaluated by scanning electron microscopy and the accessibility of enzymes and microorganisms determined using fluorescent markers in the size range of enzymes (5 nm) and microorganisms (10 µm), and fluorescent microscopy. The perforated wheat grains, as well as non-perforated grains as controls, were then incubated with selected microorganisms (Bacillus megaterium Myk145 and B. licheniformis MA572) or with the enzyme ZHD518. The two bacilli strains were not able to significantly reduce the amount of zearalenone (ZEA), neither in the perforated nor in the non-perforated wheat kernels in comparison with the controls. In contrast, the enzyme ZHD518 significantly reduced the initial concentration of ZEA in the perforated and non-perforated wheat kernels in comparison with controls. Moreover, in vitro incubation of ZHD518 with ZEA showed the presence of two non-estrogenic degradation products of ZEA: hydrolysed zearalenone (HZEA) and decarboxylated hydrolysed ZEA (DHZEA). In addition, the physical pre-treatment led to a reduction in detectable mycotoxin contents in a subset of samples. Overall, this study emphasizes the promising potential of combining physical pre-treatment approaches with biological decontamination solutions in order to address the associated problem of mycotoxin contamination and food waste reduction.


Assuntos
Contaminação de Alimentos , Triticum , Zearalenona , Zearalenona/análise , Triticum/química , Triticum/microbiologia , Contaminação de Alimentos/análise , Bacillus megaterium/enzimologia , Descontaminação/métodos , Microbiologia de Alimentos , Manipulação de Alimentos/métodos , Bacillus/enzimologia , Sementes/química , Sementes/microbiologia , Microscopia Eletrônica de Varredura
3.
J Hazard Mater ; 470: 134190, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38593659

RESUMO

Organophosphorus compounds (OPs), such as VX, pose a significant threat due to their neurotoxic and hazardous properties. Skin decontamination is essential to avoid irreversible effects. Fuller's earth (FE), a phyllosilicate conventionally employed in powder form, has demonstrated decontamination capacity against OPs. The aim of this study was to develop a formulation that forms a film on the skin, with a significant OP removal capacity (>95 %) coupled with sequestration capabilities, favorable drying time and mechanical properties to allow for easy application and removal, particularly in emergency context. Various formulations were prepared using different concentrations of polyvinyl alcohol (PVA), FE and surfactants. Their removal and sequestration capacity was tested using paraoxon-ethyl (POX), a chemical that simulates the behavior of VX. Formulations with removal capacity levels surpassing 95 % were mechanically characterized and cell viability assays were performed on Normal Human Dermal Fibroblast (NHDF). The four most promising formulations were used to assess decontamination efficacy on pig ear skin explants. These formulations showed decontamination levels ranging from 84.4 ± 4.7 % to 96.5 ± 1.3 %, which is equivalent to current decontamination methods. These results suggest that this technology could be a novel and effective tool for skin decontamination following exposure to OPs.


Assuntos
Descontaminação , Paraoxon , Pele , Descontaminação/métodos , Animais , Pele/efeitos dos fármacos , Humanos , Suínos , Paraoxon/toxicidade , Paraoxon/química , Compostos de Alumínio/química , Sobrevivência Celular/efeitos dos fármacos , Silicatos/química , Álcool de Polivinil/química , Compostos de Magnésio/química , Compostos de Magnésio/farmacologia , Tensoativos/química , Fibroblastos/efeitos dos fármacos
4.
Radiat Prot Dosimetry ; 200(7): 707-714, 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38678315

RESUMO

Decorporation therapies increase the excretion of the incorporated material and therefore may reduce the probability of the occurrence of stochastic effects and may avoid deterministic effects in persons internally contaminated with radionuclides. The decision to initiate decorporation therapy should consider the effects of treatment in relation to the benefit provided. The literature presents threshold values above which treatment is recommended. The objective of this work is to collect and summarize recommendations on decorporation therapy. Ten key topics are presented for consideration by a multidisciplinary team when assessing the risk-benefit balance for performing decorporation therapy.


Assuntos
Descontaminação , Humanos , Descontaminação/métodos , Medição de Risco/métodos , Tomada de Decisões , Radioisótopos/análise
5.
Chemosphere ; 356: 141881, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38575078

RESUMO

Acacia Senegal waste (ASW) is remaining biomass following gum Arabic harvesting and has no use mentioned in the literature as of yet. This study aims to convert ASW into valuable biochar via two comparative thermal and hydrothermal techniques, which include pyrochar ASW at 300 °C (PC ASW300) and hydrochar ASW at 180 °C (HC ASW180), respectively, for Cu (II) adsorption from aqueous solutions. SEM-EDS, FTIR, XRD, and XPS were used to characterize the biochar. Adsorption performance was studied as a function of pH, contact time, and adsorbent concentration. Adsorption kinetics were best fit for a pseudo-second-order model. And thermodynamics studies revealed that Cu (II) on biochar was endothermic, spontaneous, and best fitted to the Langmuir isotherm model. Pyrochar adsorption capacity (31.93 mg g-1) was seven times that of hydrochar (5.45 mg g-1). ASW treated with phosphorus (PC H3PO4 and HC H3PO4) prior to the carbonization altered the pore structure and surface functional groups as well (O-P-O, P-CH3, and P-OH) of biochar. It was found that treating with phosphorous acid increased adsorption capacity to 141.7 mg g-1 and 22.24 mg g-1 for PC H3PO4 and HC H3PO4, respectively. The surface functional groups of biochar resulted from lignin, alkaloids, and polysaccharides combined with Cu (II) during the adsorption process via surface complexation accompanied by π-electron interaction and Cu (II) reduction. These findings shed light on the ASW biochar potential as a new green cost-effective adsorbent and drew an insightful understanding of Cu (II) adsorption performance and mechanism. It is concluded that ASW-derived biochar is highly effective and a promising alternative for Cu (II) decontamination from wastewater.


Assuntos
Acacia , Carvão Vegetal , Cobre , Águas Residuárias , Poluentes Químicos da Água , Adsorção , Carvão Vegetal/química , Cobre/química , Acacia/química , Águas Residuárias/química , Poluentes Químicos da Água/química , Cinética , Termodinâmica , Descontaminação/métodos , Concentração de Íons de Hidrogênio , Purificação da Água/métodos , Eliminação de Resíduos Líquidos/métodos
7.
J Hosp Infect ; 143: 1-7, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38529779

RESUMO

BACKGROUND: Using robots to handle medical devices in the decontamination area of the Central Sterile Supply Department (CSSD) can reduce risks and address staff shortages. The gripper design must allow reliable cleaning using standard CSSD procedures to avoid build-up of biofilms and possible cross-contamination between different instrument trays and the gripper's functionality. This study explores the design of the robot's gripper regarding cleanability, aiming to determine whether successful cleaning can be achieved even after prolonged drying for a working shift of 8 h. METHODS: We optimized a gripper for cleanability and used it to assess the spread of different test soils depending on different forms of motion. Subsequently, we analysed the cleanability using sheep's blood as test soil, reprocessing the gripper in different assembly configurations after 4 and 8 h of drying, and measuring residual protein. FINDINGS: Based on our investigations, we documented the spread of contamination depending on the type of motion of the gripper's components. Sheep's blood exhibited the highest dispersion among the test soils, permeating through thin crevices. Importantly, all samples displayed residual protein levels below the warning threshold, irrespective of drying time and gripper disassembly or cleaning position. Cleaning in a device-specific optimized position achieved results comparable to cleaning the disassembled individual components. CONCLUSIONS: These findings indicate that cleaning even after one working shift of 8 h and without the labour-intensive disassembly of the gripper is feasible, supporting the future use of robots to handle contaminated medical devices in the CSSD decontamination area.


Assuntos
Robótica , Humanos , Descontaminação/métodos , Contaminação de Equipamentos/prevenção & controle , Instrumentos Cirúrgicos , Solo
8.
Toxicol Lett ; 395: 11-16, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38484828

RESUMO

Reactive skin decontamination lotion (RSDL) is a Health Canada approved product used by the Canadian Armed Forces for removal and inactivation of toxic chemicals on skin. Although it is considered very safe when used as directed, questions have been raised regarding whether topical RSDL in the medical setting will react exothermically with antiseptic compounds on the casualty's epidermis that could result in thermal burns. Benchtop experiments were conducted to investigate reactivity of RSDL with various antiseptic compounds or hemostatic agents. Temperature changes were closely monitored in three different volume ratios, 1:10, 1:1, and 10:1 over a time course of 16 minutes. Chlorine based bleaches versus RSDL were included as a positive control and were the only combination that exhibited a significant exothermic reaction capable of causing minor thermal burns. RSDL was also evaluated with antiseptic solution applied to swine epidermal tissue without observation of visual irritation; then in lacerated skeletal muscle tissue which resulted in no measured temperature change. The conclusion of this study is that antiseptics and hemostatic agents can be used as required on a patient decontaminated with RSDL as no exothermic reaction will occur.


Assuntos
Anti-Infecciosos Locais , Queimaduras , Hemostáticos , Humanos , Animais , Suínos , Anti-Infecciosos Locais/toxicidade , Descontaminação/métodos , Canadá , Pele
9.
J Environ Radioact ; 275: 107425, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38554648

RESUMO

As the need for global decommissioning and site remediation of aging and shut-down nuclear power plants continues to grow, it becomes increasingly crucial to efficiently treat contaminated soil while minimizing waste generation. This study explores an innovative soil decontamination approach that utilizes supercritical carbon dioxide (SCCO2) as the primary solvent, along with ethanol as a co-solvent and specific additives, including a chelate ligand (catechol ligand) and a co-ligand (NEt4PFOSA). The advantages of SCCO2, such as its penetration and solubility, coupled with its ability to separate from radioactive waste, are harnessed in this research. The study demonstrates that the combination of SCCO2, ethanol, and additives significantly enhances decontamination efficiency, particularly for cesium (Cs), strontium (Sr), and uranium (U) contamination. Results indicate that decontamination efficiency varies with soil particle size, with smaller particles presenting greater challenges. This study presents a promising eco-friendly soil decontamination technology using SCCO2 containing ethanol and specific additives to efficiently reduce radioactive contamination in soil.


Assuntos
Dióxido de Carbono , Descontaminação , Etanol , Poluentes Radioativos do Solo , Descontaminação/métodos , Poluentes Radioativos do Solo/análise , Etanol/química , Dióxido de Carbono/química , Recuperação e Remediação Ambiental/métodos , Radioisótopos de Césio/química , Solo/química
10.
J Hazard Mater ; 470: 134139, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38555674

RESUMO

In this study, the porous carbon material (FeN-BC) with ultra-high catalytic activity was obtained from waste biomass through Fe-N co-doping. The prominent degradation rate (> 96.8%) of naproxen (NAP) was achieved over a wide pH range (pH 3.0-9.0) in FeN-BC/PAA system. Unlike previously reported iron-based peracetic acid (PAA) systems with •OH or RO• as the dominated reactive species, the degradation of contaminants was attributed to singlet oxygen (1O2) produced by organic radicals (RO•) decomposition, which was proved to be thermodynamically feasible and favorable by theoretical calculations. Combining the theoretical calculations, characteristic and experimental analysis, the synergistic effects of Fe and N were proposed and summarized as follows: i) promoted the formation of extensive defects and Fe0 species that facilitated electron transfer between FeN-BC and PAA and continuous Fe(II) generation; ii) modified the specific surface area (SSA) and the isoelectric point of FeN-BC in favor of PAA adsorption on the catalyst surface. This study provides a strategy for waste biomass reuse to construct a heterogeneous catalyst/PAA system for efficient water purification and reveals the synergistic effects of typical metal-heteroatom for PAA activation.


Assuntos
Biomassa , Carvão Vegetal , Ferro , Ácido Peracético , Poluentes Químicos da Água , Purificação da Água , Ácido Peracético/química , Carvão Vegetal/química , Ferro/química , Poluentes Químicos da Água/química , Purificação da Água/métodos , Nitrogênio/química , Naproxeno/química , Catálise , Descontaminação/métodos , Adsorção
11.
Nurs Stand ; 39(5): 45-50, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38462981

RESUMO

Effective decontamination is a vital aspect of infection prevention and control, and has a crucial role in reducing healthcare-associated infections (HCAIs). Various decontamination methods can be used in healthcare settings to ensure that medical devices, equipment and the clinical environment are safe. It is essential for nurses and other healthcare staff to have adequate knowledge of the decontamination methods and infection prevention and control practices required to prevent HCAIs. This article discusses the most common HCAIs, decontamination methods that can be used, and relevant UK legislation, policies and guidance. It also outlines nurses' responsibilities in relation to infection prevention and control and the importance of education and training in this area, with a particular focus on integrating human factors.


Assuntos
Infecção Hospitalar , Descontaminação , Controle de Infecções , Humanos , Descontaminação/métodos , Reino Unido , Infecção Hospitalar/prevenção & controle , Controle de Infecções/métodos
12.
Sci Rep ; 14(1): 5715, 2024 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-38459094

RESUMO

Kidney transplantation is a common yet highly demanding medical procedure worldwide, enhancing the quality of life for patients with chronic kidney disease. Despite its prevalence, the procedure faces a shortage of available organs, partly due to contamination by microorganisms, leading to significant organ disposal. This study proposes utilizing photonic techniques associated with organ support machines to prevent patient contamination during kidney transplantation. We implemented a decontamination system using ultraviolet-C (UV-C) irradiation on the preservation solution circulating through pigs' kidneys between harvest and implant. UV-C irradiation, alone or combined with ultrasound (US) and Ps80 detergent during ex-vivo swine organ perfusion in a Lifeport® Kidney Transporter machine, aimed to reduce microbiological load in both fluid and organ. Results show rapid fluid decontamination compared to microorganism release from the organ, with notable retention. By including Ps80 detergent at 0.5% during UV-C irradiation 3 log10 (CFU mL-1) of Staphylococcus aureus bacteria previously retained in the organ were successfully removed, indicating the technique's feasibility and effectiveness.


Assuntos
Descontaminação , Detergentes , Humanos , Animais , Suínos , Descontaminação/métodos , Qualidade de Vida , Diálise Renal , Rim , Preservação de Órgãos/métodos , Perfusão
13.
Eur Biophys J ; 53(3): 133-145, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38418765

RESUMO

A new method for repackaging optical metamaterials formed from quartz spheres (fibers) of various diameters is proposed for ultraviolet C disinfection of infected liquids by pathogens (viruses and bacteria). The main idea of the new equipment is connected with the rotation of a contaminated fluid by screw channels within a metamaterial matrix prepared from UVC fibers/spherical optics, to improve the decontamination efficiency. In demonstration of the viability of this approach, dynamic and static inactivation of Baker's yeast via Ultraviolet C radiation regimes are used in this paper to show the efficacy of decontamination within the screw channels.


Assuntos
Descontaminação , Desinfecção , Descontaminação/métodos , Desinfecção/métodos , Bactérias , Raios Ultravioleta
14.
Transplant Proc ; 56(2): 427-433, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38341298

RESUMO

BACKGROUND: Bacterial infections are common after liver transplantation (LT) and cause serious morbidity and mortality. In our center, prolonged selective digestive decontamination (SDD) is the standard of care, which may lead to a reduced number and severity of bacterial infections. The aim of the current study was to investigate bacterial infection rates, the causative pathogens, localization, and the possible influence of SDD within the first year after LT. METHODS: A retrospective single-center cohort study was performed. Patients within their first year after LT between 2012 and 2017 were included. Patients received SDD for 3 weeks immediately after LT. The type of infection, bacterial subtype, CSI classification, severity, and potential interventions were recorded. RESULTS: One hundred eighty-six patients were included in the study. Seventy-eight patients (41.9%) had a bacterial infection within the first year after LT. The most common types of infection were cholangitis (25.8%) and secondary infected abdominal fluid collections (25.3%). The most common bacteria were Gram-positive enterococcal- (36.5%) and Gram-negative enterobacterial species (34.2%). 35.5% of the infections occurred within the first month after LT, mainly caused by Gram-positive bacteria (76.7%). CONCLUSIONS: Cholangitis and infected abdominal fluid are the most common types of infection within one year after LT, mainly caused by enterococcal- and enterobacterial species. Within the first month after LT, infections were mostly caused by Gram-positive bacteria, which could be a consequence of protocol use of SDD. The results can be used for the choice of empirical antibiotic therapy based on the most common types of bacteria and the time frame after LT.


Assuntos
Infecções Bacterianas , Colangite , Transplante de Fígado , Humanos , Transplante de Fígado/efeitos adversos , Transplante de Fígado/métodos , Antibacterianos/uso terapêutico , Estudos Retrospectivos , Estudos de Coortes , Descontaminação/métodos , Infecções Bacterianas/diagnóstico , Infecções Bacterianas/epidemiologia , Infecções Bacterianas/etiologia , Enterobacteriaceae , Unidades de Terapia Intensiva
15.
Waste Manag ; 178: 292-300, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38422682

RESUMO

Clean up following the wide-area release of a persistent biological agent has the potential to generate significant waste. Waste containing residual levels of biological contaminants may require off-site shipment under the U.S. Department of Transportation's (US DOT) solid waste regulations for Category A infectious agents, which has packaging and size limitations that do not accommodate large quantities. Treating the waste on-site to inactivate the bio-contaminants could alleviate the need for Category A shipping and open the possibility for categorizing the waste as conventional solid waste with similar shipping requirements as municipal garbage. To collect and package waste for on-site treatment, a semi-permeable nonwoven-based fabric was developed. The fabric was designed to contain residual bio-contaminants while providing sufficient permeability for penetration by a gaseous decontamination agent. The nonwoven fabric was tested in two bench-scale experiments. First, decontamination efficacy and gas permeability were evaluated by placing test coupons inoculated with spores of a Bacillus anthracis surrogate inside the nonwoven material. After chlorine dioxide fumigation, the coupons were analyzed for spore viability and results showed a ≥6 Log reduction on all test materials except glass. Second, filters cut from the nonwoven material were tested in parallel with commercially available cellulose acetate filters having a known pore size (0.45 µm) and results demonstrate that the two materials have similar permeability characteristics. Overall, results suggest that the nonwoven material could be used to package waste at the point of generation and then moved to a nearby staging area where it could be fumigated to inactivate bio-contaminants.


Assuntos
Bacillus anthracis , Resíduos Sólidos , Esporos Bacterianos/fisiologia , Descontaminação/métodos
16.
Clin Exp Dent Res ; 10(1): e839, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38345466

RESUMO

OBJECTIVE: To assess which decontamination method(s) used for the debridement of titanium surfaces (disks and dental implants) contaminated with bacterial, most efficiently eliminate bacterial biofilms. MATERIAL AND METHODS: A systematic search was conducted in four electronic databases between January 1, 2010 and October 31, 2022. The search strategy followed the PICOS format and included only in vitro studies completed on either dental implant or titanium disk samples. The assessed outcome variable consisted of the most effective method(s)-chemical or mechanical- removing bacterial biofilm from titanium surfaces. A meta-analysis was conducted, and data was summarized through single- and multi-level random effects model (p < .05). RESULTS: The initial search resulted in 5260 articles after the removal of duplicates. After assessment by title, abstract, and full-text review, a total of 13 articles met the inclusion criteria for this review. Different decontamination methods were assessed, including both mechanical and chemical, with the most common method across studies being chlorhexidine (CHX). Significant heterogeneity was noted across the included studies. The meta-analyses only identified a significant difference in biofilm reduction when CHX treatment was compared against PBS. The remaining comparisons did not identify significant differences between the various decontamination methods. CONCLUSIONS: The present results do not demonstrate that one method of decontamination is superior in eliminating bacterial biofilm from titanium disk and implant surfaces.


Assuntos
Implantes Dentários , Peri-Implantite , Humanos , Peri-Implantite/prevenção & controle , Implantes Dentários/microbiologia , Titânio , Descontaminação/métodos , Clorexidina , Bactérias
17.
Clin Exp Dent Res ; 10(1): e841, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38345509

RESUMO

OBJECTIVES: Access to the implant surface plays a significant role in effective mechanical biofilm removal in peri-implantitis treatment. Mechanical decontamination may also alter the surface topography of the implant, potentially increasing susceptibility to bacterial recolonization. This in vitro study aimed to evaluate a newly developed, anatomically realistic, and adaptable three-dimensional (3D)printed model with a peri-implant bone defect to evaluate the accessibility and changes of dental implant surfaces after mechanical decontamination treatment. MATERIAL AND METHODS: A split model of an advanced peri-implant bone defect was prepared using 3D printing. The function of the model was tested by mechanical decontamination of the exposed surface of dental implants (Standard Implant Straumann AG) coated with a thin layer of colored occlusion spray. Two different instruments for mechanical decontamination were used. Following decontamination, the implants were removed from the split model and photographed. Image analysis and fluorescence spectroscopy were used to quantify the remaining occlusion spray both in terms of area and total amount, while scanning electron microscopy and optical profilometry were used to analyze alteration in the implant surface morphology. RESULTS: The 3D model allowed easy placement and removal of the dental implants without disturbing the implant surfaces. Qualitative and quantitative assessment of removal of the occlusion spray revealed differences in the mechanism of action and access to the implant surface between tested instruments. The model permitted surface topography analysis following the decontamination procedure. CONCLUSION: The developed 3D model allowed a realistic simulation of decontamination of implant surfaces with colored occlusion spray in an advanced peri-implant defect. 3D printing allows easy adaptation of the model in terms of the shape and location of the defect. The model presents a valuable tool for in vitro investigation of the accessibility and changes of the implant surface after mechanical and chemical decontamination.


Assuntos
Implantes Dentários , Peri-Implantite , Humanos , Descontaminação/métodos , Propriedades de Superfície , Peri-Implantite/prevenção & controle , Microscopia Eletrônica de Varredura
18.
PLoS One ; 19(2): e0296871, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38319932

RESUMO

The Coronavirus Disease 2019 (COVID-19) pandemic has induced a critical supply of personal protective equipment (PPE) especially N95 respirators. Utilizing respirator decontamination procedures to reduce the pathogen load of a contaminated N95 respirator can be a viable solution for reuse purposes. In this study, the efficiency of a novel hybrid respirator decontamination method of ultraviolet germicidal irradiation (UVGI) which utilizes ultraviolet-C (UV-C) rays coupled with microwave-generated steam (MGS) against feline coronavirus (FCoV) was evaluated. The contaminated 3M 1860 respirator pieces were treated with three treatments (UVGI-only, MGS-only, and Hybrid-UVGI + MGS) with variable time. The virucidal activity was evaluated using the TCID50 method. The comparison of decontamination efficiency of the treatments indicated that the hybrid method achieved at least a pathogen log reduction of 4 logs, faster than MGS and UVGI. These data recommend that the proposed hybrid decontamination system is more effective comparatively in achieving pathogen log reduction of 4 logs.


Assuntos
Respiradores N95 , Vapor , Micro-Ondas , Descontaminação/métodos , Reutilização de Equipamento , Raios Ultravioleta , Pandemias
19.
Biomolecules ; 14(2)2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38397418

RESUMO

Cold atmospheric plasma has become a widespread tool in bacterial decontamination, harnessing reactive oxygen and nitrogen species to neutralize bacteria on surfaces and in the air. This technology is often employed in healthcare, food processing, water treatment, etc. One of the most energy-efficient and universal methods for creating cold atmospheric plasma is the initiation of a piezoelectric direct discharge. The article presents a study of the bactericidal effect of piezoelectric direct discharge plasma generated using the multifunctional source "CAPKO". This device allows for the modification of the method of plasma generation "on the fly" by replacing a unit (cap) on the working device. The results of the generation of reactive oxygen and nitrogen species in a buffer solution in the modes of direct discharge in air and a plasma jet with an argon flow are presented. The bactericidal effect of these types of plasma against the bacteria E. coli BL21 (DE3) was studied. The issues of scaling the treatment technique are considered.


Assuntos
Escherichia coli , Gases em Plasma , Descontaminação/métodos , Oxigênio/farmacologia , Antibacterianos/farmacologia , Gases em Plasma/farmacologia , Bactérias , Nitrogênio
20.
Photochem Photobiol Sci ; 23(2): 215-223, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38165604

RESUMO

Personal protective equipment (PPE) reuse, first recommended in the context of the SARS-CoV-2 pandemic, can mitigate shortages in crisis situations and can greatly reduce the environmental impact of typically single-use PPE. Prior to safe reuse, PPE must be sanitized and contaminating pathogens-in current circumstances viruses in particular-must be inactivated. However, many established decontamination procedures are not equitable and remain unavailable in low-resource settings. In mid-2020, an interdisciplinary consortium of researchers first studied the potential of implementing cheap and easy-to-use antimicrobial photodynamic inactivation (aPDI) using methylene blue as photosensitizer to decontaminate face masks and filtering facepiece respirators. In this perspective piece, we describe the development of this novel method, discuss recent advances, and offer insights into how equitable PPE decontamination via methylene blue-based aPDI may be integrated into circular economy policies in the healthcare sector.


Assuntos
Anti-Infecciosos , COVID-19 , Dispositivos de Proteção Respiratória , Humanos , COVID-19/prevenção & controle , Azul de Metileno , Descontaminação/métodos , Equipamento de Proteção Individual , Atenção à Saúde
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...