Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 19.232
Filtrar
1.
J Contemp Dent Pract ; 25(3): 213-220, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38690692

RESUMO

AIM: The objective of this study was to assess marginal bone level around single implants inserted in fresh extraction sockets in the anterior maxillary region and instantly restored with computer-aided design/computer-aided manufacturing customized temporary crowns cemented on the final abutment. MATERIALS AND METHODS: A total of 20 patients (15 females and 5 males, with a mean age of 30 years), where 20 were placed in fresh extraction sockets. After raising a full-thickness flap, atraumatic extraction was performed the implant site was prepared and fixtures were stabilized on the palatal bone wall. The implant location was immediately transmitted to the prepared master model using the pick-up impression coping seated in the surgical guide template. Prefabricated abutments were used as the final abutment on the master model, scanned and the crown was planned using computer-aided manufacturing customized software. Later on 8th weeks, abutments were torqued as per the manufacturer's recommendation, and the final crowns were cemented. Using personalized intraoral radiographs marginal bone level was evaluated mesially and distally to the implant shoulder as a reference at implant placement, 8 weeks, 1, 3, 5, and 10 years after loading. RESULTS: Wholly implants were osteo-integrated positively after 10 years of practical loading, but only 18 were available for clinical and radiological follow-up, and 2 patients with two implants were excluded from the study due to relocation abroad without any implant failure. The average marginal bone loss (MBL) in the current report was 0.16 ± 0.167 mm at crown cementation, 0.275 ± 0.171 mm after 1 year, 0.265 ± 0.171 mm after 3 years, 0.213 ± 0.185 mm after 5 years, and 0.217 ± 0.194 mm at 10 years. CONCLUSION: The strategy of inserting and not removing the final abutment at the time of implant placement facilitates the establishment of adequate attachment of both soft and hard tissues to the abutment surface, ensuring uninterrupted organization of tissue architecture and offers advantages in helping maintain soft tissue maturation and preventing marginal bone level. CLINICAL SIGNIFICANCE: Immediately loaded implants in freshly extracted sockets lead to a significant reduction in marginal ridge resorption. The use of a temporary crown on a prefabricated abutment, exclusive of successive abutment manipulation, proved effective in preserving the primarily founding blood clot and served as a prototype for shaping the soft tissue around the previously wounded gum. How to cite this article: Berberi A, El Zoghbi A, Aad G, et al. Immediate Loading Using the Digitalized Customized Restoration of Single-tooth Implants Placed in Fresh Extraction Sockets in the Aesthetic Anterior Maxilla: A 10-Year Prospective Study of Marginal Bone Level. J Contemp Dent Pract 2024;25(3):213-220.


Assuntos
Desenho Assistido por Computador , Coroas , Implantes Dentários para Um Único Dente , Carga Imediata em Implante Dentário , Maxila , Alvéolo Dental , Humanos , Masculino , Feminino , Estudos Prospectivos , Maxila/cirurgia , Adulto , Carga Imediata em Implante Dentário/métodos , Alvéolo Dental/cirurgia , Perda do Osso Alveolar , Dente Suporte , Estética Dentária , Extração Dentária , Prótese Dentária Fixada por Implante , Planejamento de Prótese Dentária , Projeto do Implante Dentário-Pivô , Adulto Jovem
2.
Int J Esthet Dent ; 19(2): 140-150, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38726856

RESUMO

The present technical article describes a protocol to digitally reproduce the emergence profile of an interim implant prosthesis (IP) and to transfer its macrogeometry into the definitive restoration. The purpose of this protocol was to minimize alterations in the gingival architecture developed during the interim restorative phase of a single implant that could potentially jeopardize its esthetic outcome. The process included obtaining an intraoral scan with the interim IP in situ, a duplicate of this intraoral scan that was used to capture the exact position of the implant, and an extraoral scan of the prosthesis. These data could then be imported into IOS software to create a model where the patients' soft tissue was incorporated with precision, allowing for the fabrication of a definitive crown with an optimal soft tissue adaptation. As there are few articles in the scientific literature that have reported a consistent method to replicate the emergence profile of an interim IP, the present technical article aims to highlight the potential of utilizing the emergence profile of an interim IP created by IOS software.


Assuntos
Software , Humanos , Estética Dentária , Desenho Assistido por Computador , Coroas , Prótese Dentária Fixada por Implante/métodos , Restauração Dentária Temporária/métodos , Planejamento de Prótese Dentária/métodos , Implantes Dentários para Um Único Dente
3.
Int J Esthet Dent ; 19(2): 186-194, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38726859

RESUMO

OBJECTIVE: A diagnostic mock-up is a key tool that allows a preview of the outcome of an esthetic restoration. With recent developments in CAD/CAM technology, it is important to understand the pros and cons of chairside digital dentistry and the restorative materials used. The aim of the present case report is to describe in detail the use of a 3D-printed mock-up fabricated from a polymer-based material for an esthetic treatment plan within a fully digital workflow. CASE REPORT: A 45-year-old female patient presented at the clinic concerned about her esthetic appearance and the color of her anterior incisors. After a conclusive diagnosis, a restoration was planned using ceramic veneers from maxillary premolar to premolar. For a preview visualization of the outcome, an intraoral scanner was used to obtain 3D images and to allow the design of a digital smile. The template STL file was exported to a 3D printer and a 0.6-mm mock-up in A3-shade 3D resin was produced after 25 min. The mock-up was tested through a try-in and approved by the patient. As a result, the printed mock-up was considered predictable and reliable for the final restoration. CONCLUSIONS: The ease, speed, and reduced costs derived from the digital workflow, in conjunction with the accuracy of the mock-up, made the procedure highly efficient and recommendable.


Assuntos
Desenho Assistido por Computador , Estética Dentária , Impressão Tridimensional , Humanos , Feminino , Pessoa de Meia-Idade , Facetas Dentárias , Planejamento de Prótese Dentária/métodos , Cerâmica , Incisivo/diagnóstico por imagem
4.
Int J Oral Implantol (Berl) ; 17(2): 175-185, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38801331

RESUMO

PURPOSE: The reverse guided bone regeneration protocol is a digital workflow that has been introduced to reduce the complexity of guided bone regeneration and promote prosthetically guided bone reconstruction with a view to achieving optimal implant placement and prosthetic finalisation. The aim of the present study was to investigate the accuracy of this digital protocol. MATERIALS AND METHODS: Sixteen patients with partial edentulism in the maxilla or mandible and with vertical or horizontal bone defects were treated using the reverse guided bone regeneration protocol to achieve fixed implant rehabilitations. For each patient, a digital wax-up of the future rehabilitation was created and implant planning was carried out, then the necessary bone reconstruction was simulated virtually and the CAD/CAM titanium mesh was designed and used to perform guided bone regeneration. The computed tomography datasets from before and after guided bone regeneration were converted into 3D models and aligned digitally. The actual position of the mesh was compared to the virtual position to assess the accuracy of the digital project. Surgical and healing complications were also recorded. A descriptive analysis was conducted and a one-sample t test and Wilcoxon test were utilised to assess the statistical significance of the accuracy. The level of significance was set at 0.05. RESULTS: A total of 16 patients with 16 treated sites were enrolled. Comparing the virtually planned mesh position with the actual position, an overall mean discrepancy between the two of 0.487 ± 0.218 mm was achieved. No statistically significant difference was observed when comparing this to a predefined minimum tolerance (P = 0.06). No surgical complications occurred, but two healing complications were recorded (12.5%). CONCLUSION: Within the limitations of the present study, the reverse guided bone regeneration digital protocol seems to be able to achieve good accuracy in reproducing the content of the virtual plan. Nevertheless, further clinical comparative studies are required to confirm these results.


Assuntos
Regeneração Óssea , Desenho Assistido por Computador , Telas Cirúrgicas , Titânio , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Adulto , Tomografia Computadorizada por Raios X/métodos , Arcada Parcialmente Edêntula/cirurgia , Arcada Parcialmente Edêntula/reabilitação , Implantação Dentária Endóssea/métodos , Resultado do Tratamento , Imageamento Tridimensional/métodos , Regeneração Tecidual Guiada Periodontal/métodos
5.
PLoS One ; 19(5): e0301440, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38809934

RESUMO

Computer-aided design (CAD) models can now be directly converted into products and structures. One technique to realize such approach is through Additive Manufacturing (AM). AM is relatively new manufacturing technology in which products are manufactured by layering various materials like rubber, metal, ceramic, composites, and polymers. However, the use of this technology requires consideration of its associated cost to ensure its competitiveness. In this paper, a simplified mathematical cost model is suggested. The model considers the main components of costs. The model formula utilizes expenses related to the pre-processing, main processing, and the post-processing operations. To validate the model, it is tested to estimate the cost of medical implants manufacturing using AM technique. In many cases, medical implants require unique or dedicated design for each patient. Hence cost estimation will help to assess and estimate the required financial resources for such operations. A case study is provided in this paper to estimate the manufacturing cost of a finger's phalanges bone, with metal implant using AM technique. The developed model may be described as Activity Based Costing (ABC). The model is introduced to estimate the cost of parts produced using AM technique. Although the model is developed to suit custom implant manufacturing using AM technique, its use may also be adapted to suit the manufacturing of many other parts and products. The developed model is aiming to achieve several tasks namely assigning cost drivers to each activity, estimating the cost of individual actions, allocating overhead expenses, calculating the overall production cost, and establishing an acceptable selling price. It assists companies in computing the cost of custom implants for customers, enhancing the accuracy of production cost estimates, and ultimately boosting profitability.


Assuntos
Desenho Assistido por Computador , Próteses e Implantes , Próteses e Implantes/economia , Desenho Assistido por Computador/economia , Humanos , Custos e Análise de Custo , Modelos Teóricos , Modelos Econômicos , Desenho de Prótese/economia
6.
BMC Oral Health ; 24(1): 641, 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38816807

RESUMO

BACKGROUND: Different processing techniques are employed to obtain poly (methyl methacrylate) (PMMA) with consistent surface quality in terms of topography and tribological function. The purpose of this research is to evaluate its influence on the surface height distribution. METHODS: In this research, samples of conventional and CAD/CAM acrylic resins were prepared. The following surface roughness parameters were extracted from the profilometric readings: arithmetic mean roughness (Pa), skewness (Psk) and kurtosis (Pku). Profilometric profiles were additionally obtained. RESULTS: The average roughness (Pa) with the conventional technique was significantly higher compared to CAD/CAM (t = 4.595; P < 0.001). Heat-cured resins presented the highest mean Pa (F = 6.975; P = 0.06). Heat-cured and milled resins show lower coefficient variation (CV) values, indicating more consistent surface finishing. The surface profiles revealed distinct characteristics in terms of skewness and kurtosis. CONCLUSIONS: The surface processing method, chemical composition and resin type significantly influence the surface finishing of the resin. The CAD/CAM resins exhibited superior results in terms of surface arithmetic mean roughness (Pa). However, heat-cured resin revealed to present the better surface consistency.


Assuntos
Resinas Acrílicas , Desenho Assistido por Computador , Teste de Materiais , Polimetil Metacrilato , Propriedades de Superfície , Resinas Acrílicas/química , Polimetil Metacrilato/química , Materiais Dentários/química , Humanos , Temperatura Alta
7.
BMC Oral Health ; 24(1): 618, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38807102

RESUMO

PURPOSE: This study aimed to investigate the effects of new and used burs on CAD-CAM PMMA resin color changes following thermocycling. MATERIALS AND METHODS: Twenty disk-shaped specimens (10 × 2 mm) were made using a single brand of CAD-CAM polymethyl methacrylate resin (Polident) for the color test. Group N consisted of half of the specimens that were machined using the new tungsten carbide bur set, and Group U consisted of the specimens that were milled using the used bur set (500 machining time). A color test was performed on the specimens both before and after thermocycling. For the statistical analysis, the Kruskal-Wallis and Dunn Pairwise Comparison tests were employed. RESULTS: The ∆E* value of specimens (2.057) milled with the used bur was higher than those of specimens milled with the new bur (0.340), but this value is within clinically acceptable limits. After thermocycling, specimens milled with the utilized burs had the greatest L* (93.850) and b* (5.000) values. After thermocycling, statistically significant differences were discovered between Group N and Group U as well as between specimens milled with the utilized bur before and after thermocycling. CONCLUSION: Thermocycling process have an effect on the mean ∆E values of specimens milled with the used carbide bur, but these ∆E* values were not statistically significant. CLINICAL SIGNIFICANCE: The color and clinical performance of CAD-CAM restorations may be affected by variations in CAD-CAM milling bur properties, particularly those related to their frequent use.


Assuntos
Cor , Desenho Assistido por Computador , Polimetil Metacrilato , Polimetil Metacrilato/química , Teste de Materiais , Materiais Dentários/química , Propriedades de Superfície , Humanos
8.
BMC Oral Health ; 24(1): 620, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38807109

RESUMO

BACKGROUND: The mechanical properties of fully crystallized lithium aluminosilicate ceramics may be influenced by intraoral temperature variations and postmilling surface treatment. The purpose of this study is to explore the interplay among glazing, thermocycling, and the mechanical characteristics (namely, fracture toughness and hardness) of fully crystallized lithium aluminosilicate ceramics. METHODS: Bending bars (n = 40) cut from LisiCAD blocks (GC, Japan) were randomly assigned to glazed or unglazed groups (n = 20) and subjected to the single edge v-notch beam method to create notches. A glazing firing cycle was applied to the glazed group, while the unglazed group was not subjected to glazing. Half of the specimens (n = 10) from both groups underwent thermocycling before fracture toughness testing. The fracture toughness (KIC) was evaluated at 23 ± 1 °C using a universal testing machine configured for three-point bending, and the crack length was measured via light microscopy. Seven specimens per group were selected for the hardness test. Hardness was assessed using a Vickers microhardness tester with a 1 kg load for 20 s, and each specimen underwent five indentations following ISO 14705:2016. The Shapiro-Wilk and Kolmogorov-Smirnov tests were used to evaluate the normality of the data and a two-way ANOVA was utilized for statistical analysis. The significance level was set at (α = 0.05). RESULTS: Regardless of the thermocycling conditions, the glazed specimens exhibited significantly greater fracture toughness than did their unglazed counterparts (P < 0.001). Thermocycling had no significant impact on the fracture toughness of either the glazed or unglazed specimens. Furthermore, statistical analysis revealed no significant effects on hardness with thermocycling in either group, and glazing alone did not substantially affect hardness. CONCLUSIONS: The impact of glazing on the fracture toughness of LiSiCAD restorations is noteworthy, but it has no significant influence on their hardness. Furthermore, within the parameters of this study, thermocycling was found to exert negligible effects on both fracture toughness and hardness.


Assuntos
Silicatos de Alumínio , Cerâmica , Desenho Assistido por Computador , Dureza , Teste de Materiais , Cerâmica/química , Silicatos de Alumínio/química , Análise do Estresse Dentário , Propriedades de Superfície , Cristalização
9.
Int J Implant Dent ; 10(1): 21, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38691252

RESUMO

BACKGROUND: Beta-tricalcium phosphate (ß-TCP) is a biocompatible ceramic material widely used in the field of oral regeneration. Due to its excellent biological and mechanical properties, it is increasingly utilized for alveolar ridge augmentation or guided bone regeneration (GBR). With recent advances in computer-aided design and manufacturing (CAD/CAM), ß-TCP can now be used in the form of digitally designed patient-specific scaffolds for customized bone regeneration (CBR) of advanced defects in a two-stage implant therapy concept. In this case report following the CARE case report guidelines, we present a novel application of a patient-specific ß-TCP scaffold in pre-implant mandibular alveolar ridge augmentation. CASE PRESENTATION: A 63-year-old female patient with significant horizontal bone loss in the posterior mandible was treated with a custom ß-TCP scaffold in the context of a two-stage backward-planned implant therapy. Cone-beam computed tomography nine months after augmentation showed successful integration of the scaffold into the surrounding bone, allowing implant placement. Follow-up until two years after initial surgery showed excellent oral and peri-implant health. CONCLUSIONS: This case highlights the potential of patient-specific ß-TCP scaffolds for alveolar ridge augmentation and their advantage over traditional techniques, including avoidance of xeno-, allo-, and autografts. The results provide encouraging evidence for their use in clinical practice. Patient-specific ß-TCP scaffolds may be a promising alternative for clinicians seeking to provide their patients with safe, predictable, and effective alveolar ridge augmentation results in customized bone regeneration procedures.


Assuntos
Aumento do Rebordo Alveolar , Fosfatos de Cálcio , Tomografia Computadorizada de Feixe Cônico , Alicerces Teciduais , Humanos , Aumento do Rebordo Alveolar/métodos , Fosfatos de Cálcio/uso terapêutico , Feminino , Pessoa de Meia-Idade , Mandíbula/cirurgia , Regeneração Óssea/efeitos dos fármacos , Implantação Dentária Endóssea/métodos , Desenho Assistido por Computador , Perda do Osso Alveolar/cirurgia
10.
BMC Oral Health ; 24(1): 523, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702708

RESUMO

BACKGROUND: The rising demand for improved aesthetics has driven the utilization of recently introduced aesthetic materials for creating custom post and core restorations. However, information regarding the fracture resistance of these materials remains unclear, which limits their practical use as custom post and core restorations in clinical applications. AIM OF THE STUDY: This study aimed to evaluate the fracture resistance of three non-metallic esthetic post and core restorations and their modes of failure. MATERIALS AND METHODS: Thirty-nine single-rooted human maxillary central incisors were endodontically treated. A standardized post space preparation of 9mm length was performed to all teeth to receive custom-made post and core restorations. The prepared teeth were randomly allocated to receive a post and core restoration made of one of the following materials (n=13): glass fiber-reinforced composite (FRC), polyetheretherketone (PEEK) and polymer-infiltrated ceramic-network (PICN). An intraoral scanner was used to scan all teeth including the post spaces. Computer-aided design and computer-aided manufacturing (CAD-CAM) was used to fabricate post and core restorations. Post and core restorations were cemented using self-adhesive resin cement. All specimens were subjected to fracture resistance testing using a universal testing machine. Failure mode analysis was assessed using a stereomicroscope and SEM. The data was statistically analyzed using One-Way ANOVA test followed by multiple pairwise comparisons using Bonferroni adjusted significance level. RESULTS: Custom PEEK post and core restorations displayed the least fracture load values at 286.16 ± 67.09 N. In contrast, FRC exhibited the highest average fracture load at 452.60 ± 105.90 N, closely followed by PICN at 426.76 ± 77.99 N. In terms of failure modes, 46.2% of specimens with PICN were deemed non-restorable, while for PEEK and FRC, these percentages were 58.8% and 61.5%, respectively. CONCLUSIONS: Within the limitation of this study, both FRC and PICN demonstrated good performance regarding fracture resistance, surpassing that of PEEK.


Assuntos
Resinas Compostas , Desenho Assistido por Computador , Falha de Restauração Dentária , Estética Dentária , Técnica para Retentor Intrarradicular , Humanos , Cerâmica , Análise do Estresse Dentário , Benzofenonas , Incisivo/lesões , Materiais Dentários/química , Polietilenoglicóis , Cetonas/química , Polímeros , Vidro , Teste de Materiais , Planejamento de Prótese Dentária
11.
Am J Dent ; 37(2): 59-65, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38704847

RESUMO

PURPOSE: To investigate the effect of toothbrushing with new and used toothbrushes on the surface of resin composites and dental enamel. METHODS: The extracted human incisors were selected after vestibular enamel surfaces (ES) were examined. Disc-shaped specimens of direct composite (DC) and indirect composite (IC) were fabricated. Computer-aided design-computer-aided manufacturing (CAD-CAM) composite blocks (CC) were sliced in 2 mm thickness (n= 8). The surface roughness, gloss, and color were measured. The measurements were performed before and after 3 months of toothbrushing simulation (TBS) for 2,500 circular cycles. The wear index was calculated by using the ImageJ program. The specimens were subjected to an additional 2,500 cycles and the same measurements were repeated. RESULTS: No significant increase in surface roughness values was observed in DC, IC, and CC groups after 3 and 6 months of TBS except in the ES group. The highest change in surface gloss was observed in the DC group. Although the wear index of toothbrushes increased over time, only the increase in the IC group was statistically significant (P= 0.033). CLINICAL SIGNIFICANCE: Changes in surface roughness, gloss, and discoloration of the dental enamel and restorations and wear of toothbrush bristles were increased over time.


Assuntos
Resinas Compostas , Esmalte Dentário , Propriedades de Superfície , Escovação Dentária , Escovação Dentária/instrumentação , Humanos , Resinas Compostas/química , Desenho Assistido por Computador , Teste de Materiais
12.
Am J Dent ; 37(2): 71-77, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38704849

RESUMO

PURPOSE: To investigate the effect of painless low-power Er:YAG laser irradiation of conventional and polymer-infiltrated ceramic network (PICN) type CAD-CAM resin-based composites (RBCs) on resin bonding. METHODS: An Er:YAG laser system, phosphoric acid etchant, universal adhesive, RBC, and two types of CAD-CAM RBC block were used. Microtensile bond strength, fracture mode, scanning electron microscopy (SEM) observations of bonding interfaces and CAD-CAM surfaces, and surface roughness of ground and pretreated surfaces were investigated. As pretreatment methods, low-power Er:YAG laser irradiation and air-abrasion with alumina particles were used. RESULTS: The effect of low-power Er:YAG laser irradiation of CAD-CAM RBCs on bonding to repair resin varied depending on the type of CAD-CAM RBCs. CLINICAL SIGNIFICANCE: The low-power Er:YAG laser irradiation of the conventional CAD-CAM RBCs was shown to be effective as a surface pretreatment for resin bonding, while the laser irradiation of PICN-type CAD-CAM RBCs was not effective.


Assuntos
Resinas Compostas , Desenho Assistido por Computador , Colagem Dentária , Lasers de Estado Sólido , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Resinas Compostas/química , Resistência à Tração , Teste de Materiais , Humanos , Cerâmica/química , Condicionamento Ácido do Dente
13.
BMC Infect Dis ; 24(1): 476, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38714948

RESUMO

Severe fever with thrombocytopenia syndrome (SFTS) is an emerging tick-borne viral disease caused by the SFTS virus (Dabie bandavirus), which has become a substantial risk to public health. No specific treatment is available now, that calls for an effective vaccine. Given this, we aimed to develop a multi-epitope DNA vaccine through the help of bioinformatics. The final DNA vaccine was inserted into a special plasmid vector pVAX1, consisting of CD8+ T cell epitopes, CD4+ T cell epitopes and B cell epitopes (six epitopes each) screened from four genome-encoded proteins--nuclear protein (NP), glycoprotein (GP), RNA-dependent RNA polymerase (RdRp), as well as nonstructural protein (NSs). To ascertain if the predicted structure would be stable and successful in preventing infection, an immunological simulation was run on it. In conclusion, we designed a multi-epitope DNA vaccine that is expected to be effective against Dabie bandavirus, but in vivo trials are needed to verify this claim.


Assuntos
Epitopos de Linfócito T , Phlebovirus , Febre Grave com Síndrome de Trombocitopenia , Vacinas de DNA , Vacinas Virais , Vacinas de DNA/imunologia , Vacinas de DNA/genética , Phlebovirus/imunologia , Phlebovirus/genética , Febre Grave com Síndrome de Trombocitopenia/prevenção & controle , Febre Grave com Síndrome de Trombocitopenia/imunologia , Epitopos de Linfócito T/imunologia , Epitopos de Linfócito T/genética , Vacinas Virais/imunologia , Vacinas Virais/genética , Humanos , Desenho Assistido por Computador , Epitopos de Linfócito B/imunologia , Epitopos de Linfócito B/genética , Animais , Biologia Computacional
14.
Comput Biol Med ; 175: 108550, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38701590

RESUMO

BACKGROUND AND OBJECTIVE: Complete denture is a common restorative treatment in dental patients and the design of the core components (major connector and retentive mesh) of complete denture metal base (CDMB) is the basis of successful restoration. However, the automated design process of CDMB has become a challenging task primarily due to the complexity of manual interaction, low personalization, and low design accuracy. METHODS: To solve the existing problems, we develop a computer-aided Segmentation Network-driven CDMB design framework, called CDMB-SegNet, to automatically generate personalized digital design boundaries for complete dentures of edentulous patients. Specifically, CDMB-SegNet consists of a novel upright-orientation adjustment module (UO-AM), a dental feature-driven segmentation network, and a specific boundary-optimization design module (BO-DM). UO-AM automatically identifies key points for locating spatial attitude of the three-dimensional dental model with arbitrary posture, while BO-DM can result in smoother and more personalized designs for complete denture. In addition, to achieve efficient and accurate feature extraction and segmentation of 3D edentulous models with irregular gingival tissues, the light-weight backbone network is also incorporated into CDMB-SegNet. RESULTS: Experimental results on a large clinical dataset showed that CDMB-SegNet can achieve superior performance over the state-of-the-art methods. Quantitative evaluation (major connector/retentive mesh) showed improved Accuracy (98.54 ± 0.58 %/97.73 ± 0.92 %) and IoU (87.42 ± 5.48 %/70.42 ± 7.95 %), and reduced Maximum Symmetric Surface Distance (4.54 ± 2.06 mm/4.62 ± 1.68 mm), Average Symmetric Surface Distance (1.45 ± 0.63mm/1.28 ± 0.54 mm), Roughness Rate (6.17 ± 1.40 %/6.80 ± 1.23 %) and Vertices Number (23.22 ± 1.85/43.15 ± 2.72). Moreover, CDMB-SegNet shortened the overall design time to around 4 min, which is one tenth of the comparison methods. CONCLUSIONS: CDMB-SegNet is the first intelligent neural network for automatic CDMB design driven by oral big data and dental features. The designed CDMB is able to couple with patient's personalized dental anatomical morphology, providing higher clinical applicability compared with the state-of-the-art methods.


Assuntos
Prótese Total , Humanos , Planejamento de Dentadura/métodos , Redes Neurais de Computação , Desenho Assistido por Computador
15.
BMC Oral Health ; 24(1): 550, 2024 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-38734597

RESUMO

BACKGROUND: Large cross-arch free-end surgical guides can obscure the visual field, compromising surgical accuracy due to insufficient stability at the free-end. This in vitro study aims to evaluate the accuracy of novel digital non-cross-arch surgical guides designed for implant placement at the mandibular free-end, incorporating tooth undercut retention and screw-bone support. MATERIALS AND METHODS: A mandibular dental model lacking left molars was utilized to fabricate unilateral (cross-arch) tooth-supported surgical guides (GT I, n = 20). Subsequently, two additional types of surgical guides were fabricated: GT II (covering two teeth, n = 20) and GT III (covering three teeth, n = 20). These novel surgical guides were designed to utilize the undercut of the supporting teeth for retention and enhance stability with screw-bone support at the guide's free-end. Furthermore, 60 identical guiding blocks were assembled on the three types of surgical guides to facilitate the implants' insertion. On a phantom head, 120 implant replicas were placed at the Federal Dentaire Internationale (FDI) teeth positions #36 and #37 on the dental model, employing a combination of surgical guides and guiding blocks. To assess accuracy, planned and placed implant positions were compared using intraoral optical scanning. Discrepancies in angulation and linear deviations, including the coronal/apical 3D deviations, lateral deviation as well as depth deviation, were measured. Statistical analysis was performed using two-way ANOVA and Bonferroni test (α = 0.05). RESULTS: GT I exhibited significantly largest discrepancies, including angular and linear deviations at the crest and apex at every implant site. Especially in depth, at implant site #36, the mean deviation value of GT I (0.27 ± 0.13 mm) was twice as large as GT III (0.13 ± 0.07 mm), and almost twice as large as GT II (0.14 ± 0.08 mm). However, at implant site #37, this deviation increased to almost a five-fold relationship between GT I (0.63 ± 0.12 mm) and II (0.14 ± 0.09 mm), as well as between GT I and III (0.13 ± 0.09 mm). No significant discrepancies existed between the novel surgical guides at either implant site #36 or #37. CONCLUSION: This study provides a practical protocol for enhancing accuracy of implant placement and reducing the size of free-end surgical guides used at mandibular molar sites.


Assuntos
Parafusos Ósseos , Mandíbula , Modelos Dentários , Cirurgia Assistida por Computador , Humanos , Mandíbula/cirurgia , Cirurgia Assistida por Computador/métodos , Implantação Dentária Endóssea/métodos , Desenho Assistido por Computador , Técnicas In Vitro
16.
BMJ Case Rep ; 17(5)2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38749520

RESUMO

This case report focuses on the replacement of ceramic laminate veneers with suboptimal marginal fit and design, employing a digital workflow and CAD-CAM technology. The patient, a woman in her 30s, expressed concerns about the appearance and hygiene challenges of her existing veneers. A comprehensive assessment, including clinical examination, facial photographs and intraoral scanning, was conducted. Utilising CAD software, facial photographs and 3D models merged to create a digital wax-up, crucial in designing suitable veneers and addressing issues like overcontouring and a poor emergence profile. Following the removal of old veneers, a mock-up was performed and approved. Preparations ensured space for restorations with well-defined margins. The final restorations, milled with Leucite-reinforced vitreous ceramic, were cemented. At the 1 year follow-up, improved aesthetics, gingival health and functional restorations were observed. This report highlights the efficacy of digital workflows in achieving consistent and aesthetically pleasing outcomes in ceramic laminate veneer replacement.


Assuntos
Cerâmica , Desenho Assistido por Computador , Facetas Dentárias , Fluxo de Trabalho , Humanos , Feminino , Adulto , Estética Dentária , Planejamento de Prótese Dentária/métodos , Porcelana Dentária
17.
Clin Oral Investig ; 28(6): 320, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38750145

RESUMO

OBJECTIVES: The purpose of this scoping review was to identify different methods employed for recording the maxillomandibular relationship (MMR) for computer-aided designed and manufactured (CAD-CAM) complete dentures (CDs). MATERIALS AND METHODS: This scoping review followed the PRISMA-ScR guidelines and was developed according to Arksey and O'Malley and The Joanna Briggs Institute protocol. The methods were registered on the Open Science Framework (< osf.io/rf4xm> ). The focus question was: "What are the different techniques for recording the maxillomandibular relationship in the digital workflow used in CECDs?" Two investigators searched 3 online databases [MEDLINE (PubMed), Scopus, and Science Direct] independently. The inclusion criteria were clinical studies and reviews that assessed techniques for recording MMR using digital workflow for manufacturing of CECDs. A descriptive analysis was performed considering the study design, manufacturing system, clinical steps, and tools for the determination of MMR, and the difficulty level of procedures. RESULTS: 4779 articles were identified in the electronic search and 10 studies were included for data analysis. The review identified 4 commercially available CAD-CAM denture systems and 3 innovative methods suitable for abbreviating the number of appointments (2 to 4 visits). The trial denture is inherent to the procedure for the Baltic System and 3 innovative techniques. Three techniques (2 innovative and WholeYouNexteeth) demonstrated lower difficulty levels for performing the clinical procedures, regardless of the professional skills. CONCLUSIONS: The commercially available and innovative techniques for the recording of MMR may provide predictability of the treatment. The techniques are effective, however, rely on the learning curve and the patient's clinical condition. CLINICAL RELEVANCE: Recording of the maxillomandibular relationship is paramount for the manufacturing and functionality of complete dentures. Clinicians should be aware of the different tools and techniques described for registering the jaw relationship.


Assuntos
Desenho Assistido por Computador , Planejamento de Dentadura , Prótese Total , Humanos , Planejamento de Dentadura/métodos , Registro da Relação Maxilomandibular/métodos
18.
J Adhes Dent ; 26(1): 125-134, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38770704

RESUMO

PURPOSE: To investigate the effect of adhesive type and long-term aging on the shear bond strength (SBS) between silica-based ceramics and composite cement (CC). MATERIALS AND METHODS: Lithium-silicate (LS), feldspathic (FD) and polymer-infiltrated ceramic (PIC) blocks were sectioned (10 x 12 x 2 mm) and divided into 24 groups considering the factors: "ceramics" (LS, FD, and PIC), "adhesive" (Ctrl: without adhesive; 2SC: 2-step conventional; 3SC: 3-step conventional; 1SU: 1-step universal), and "aging" (non-aged or aged [A]). After the surface treatments, CC cylinders (n = 15, Ø = 2 mm; height = 2 mm) were made and half of the samples were subjected to thermocycling (10,000) and stored in water at 37°C for 18 months. The samples were submitted to SBS testing (100 kgf, 1 mm/min) and failure analysis. Extra samples were prepared for microscopic analysis of the adhesive interface. SBS (MPa) data was analyzed by 3-way ANOVA and Tukey's test (5%). Weibull analysis was performed on the SBS data. RESULTS: All factors and interactions were significant for SBS (p<0.05). Before aging, there was no significant difference between the tested groups and the respective control groups. After aging, the LS_1SU (22.18 ± 7.74) and LS_2SC (17.32 ± 5.86) groups exhibited significantly lower SBS than did the LS_Ctrl (30.30 ± 6.11). Only the LS_1SU group showed a significant decrease in SBS after aging vs without aging. The LS_1SU (12.20) group showed the highest Weibull modulus, which was significantly higher than LS_2SC_A (2.82) and LS_1SU_A (3.15) groups. CONCLUSION: No type of adhesive applied after silane benefitted the long-term adhesion of silica-based ceramics to CC in comparison to the groups without adhesive.


Assuntos
Cerâmica , Colagem Dentária , Teste de Materiais , Cimentos de Resina , Resistência ao Cisalhamento , Dióxido de Silício , Dióxido de Silício/química , Cerâmica/química , Fatores de Tempo , Cimentos de Resina/química , Desenho Assistido por Computador , Propriedades de Superfície , Análise do Estresse Dentário , Cimentação/métodos , Porcelana Dentária/química , Humanos , Resinas Compostas/química , Cimentos Dentários/química , Compostos de Potássio/química , Silicatos de Alumínio/química , Temperatura
20.
Clin Exp Dent Res ; 10(3): e899, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38752461

RESUMO

BACKGROUND: The aim of this study was to determine if different types of core substrates have any effect on the trueness and precision of digital intraoral impressions. MATERIAL AND METHODS: A customized typodont with four similar cores of natural dentine, composite, metal (Ni-Cr), and zirconia in the position of premolars was fabricated. The study model was scanned five times with two types of intraoral scanners (Carestream 3600 and 3Shape Trios 3), and a reference standard scan was obtained using a laboratory scanner (3shape D1000). A metrology software (Geomagic X) was used to align the data of experimental scans and the reference scan to determine deviation values (trueness). Precision values were calculated with random superimposition in each intraoral scanner group. The Kruskal-Wallis test was used to compare differences between different substrates, and the Mann-Whitney test was used to compare the average values between the two scanners. RESULTS: Trios 3 was found to be significantly truer and more precise than Carestream 3600 (p value = .005, <0.001). There were no significant differences in the trueness of different substrates when they were scanned by Trios 3, while different materials showed significantly different trueness values in the Carestream 3600 group (p value = .003). Dentin showed the best trueness, and zirconia performed worse than other substrates. Regarding the precision of the scanners, neither of the scanners was affected by the type of scanning substrate. CONCLUSION: For Carestream 3600, substrate type did impact the trueness of intraoral scans, with dentin and zirconia showing the highest and lowest accuracy, respectively, while Trios 3 was similarly accurate across all substrates. Trios 3 had both higher trueness and precision than Carestream 3600.


Assuntos
Técnica de Moldagem Odontológica , Humanos , Técnica de Moldagem Odontológica/instrumentação , Zircônio/química , Desenho Assistido por Computador , Modelos Dentários , Reprodutibilidade dos Testes , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...