Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
1.
Forensic Sci Int ; 327: 110967, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34455400

RESUMO

Skeletal preparation has become an integral component within the field of forensic anthropology. The aim of this study was to determine which commercial detergent was most effective and efficient for use in skeletal preparation. The hind limbs of 24 pigs (Sus scrofa) and five detergents with bleaching agents and enzymes (Surf and Ariel), only enzymes (OMO Auto and Sunlight powder) or only bleaching agents (Sunlight dishwashing liquid) were used. Specimens were skinned and immersed into a pre-heated 6 L detergent solution or tap water and macerated at either 45 °C, 50 °C, 55 °C and 60 °C. When maceration was deemed complete any remaining soft tissue was manually removed under running tap water and the remains left to dry. A scoring system was utilized to assess the effectiveness and efficiency of each detergent. OMO Auto specimens only required a single day to complete macerate regardless of the temperature and these specimens constantly scored better than the other detergents used, thus making it the most effective and efficient detergent tested.


Assuntos
Detergentes/classificação , Detergentes/normas , Antropologia Forense , Membro Posterior , Manejo de Espécimes/métodos , Animais , Sus scrofa
3.
Clin Toxicol (Phila) ; 59(5): 392-399, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32960108

RESUMO

OBJECTIVES: To evaluate the impact of the ASTM International (formerly American Society of Testing Materials) safety standard and associated product safety changes on accidental exposures to liquid laundry packets (LLPs) in children. METHODS: The National Poison Data System was queried for reports of accidental exposures to LLPs in children <6 years old received from 01 July 2012 to 31 December 2018. In 2014, ASTM International began developing a standard specifying voluntary product changes to reduce the risk of LLP exposures in young children. Product changes were made between 2013 and 2016. Exposures were grouped into baseline, transition, and post periods based on the timing of the standard's implementation. Exposure counts and sales adjusted rates were compared between the baseline and post period for all exposures and exposures involving healthcare facility (HCF) evaluation, HCF admission, and major medical outcomes. RESULTS: A total of 73,942 accidental exposures in children <6 years old were reported (baseline: 10,229, 13.8%; transition: 43,507, 58.8%; post: 20,206, 27.3%). The percentage of exposures involving HCF evaluation (41.5% to 33.8%), HCF admission (4.5% to 1.9%), and major medical outcomes (0.6% to 0.1%) decreased from the baseline to post period. Sales adjusted rates of all exposures decreased 57.4% (4.920-2.094 exposures/1 million packets sold). Decreases also occurred in HCF evaluations (65.0% decrease; 2.026-0.708 exposures/1 million packets sold), HCF admissions (81.4% decrease; 0.218-0.041 exposures/1 million packets sold), and major medical outcomes (90.9% decrease; 0.030-0.003 exposures/1 million packets sold). CONCLUSIONS: The morbidity of accidental exposures to LLPs in children decreased substantially following implementation of the ASTM International safety standard. Ongoing monitoring should be performed to determine if additional safety measures are required.


Assuntos
Prevenção de Acidentes/estatística & dados numéricos , Prevenção de Acidentes/normas , Qualidade de Produtos para o Consumidor/normas , Detergentes/normas , Guias como Assunto , Embalagem de Produtos/normas , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Estudos Retrospectivos , Estados Unidos
4.
Wound Manag Prev ; 66(11): 31-42, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33206627

RESUMO

Biofilms are believed to be a source of chronic inflammation in non-healing wounds. PURPOSE: In this study, the pre-clinical anti-biofilm efficacy of several wound cleansers was examined using the Calgary minimum biofilm eradication concentration (MBEC) and ex vivo porcine dermal explant (PDE) models on Pseudomonas aeruginosa, methicillin-resistant Staphylococcus aureus (MRSA), and Candida albicans biofilms. METHODS: A surfactant-based cleanser and antimicrobial-based cleansers containing ionic silver, hypochlorous acid (HOCl), sodium hypochlorite (NaOCl), and polyhexamethylene biguanide (PHMB) were tested on the MBEC model biofilms with a 10-minute application time. Select cleansers were then tested on the mature PDE biofilms with 10-minute applications followed by the application of cleanser-soaked gauze. The PDE model was further expanded to include single and daily applications of the cleansers to mimic daily and 72-hour dressing changes. RESULTS: In the MBEC model, PHMB- and HOCl-based cleansers reduced immature MRSA, C albicans, and P aeruginosa biofilm regrowth by > 3× when compared with silver, surfactant, and saline cleansers. The major differences could be elucidated in the PDE model in which, after daily application, 1 PHMB-based cleanser showed a statistically significant reduction (3-8 CFU/mL log reduction) in all mature biofilms tested, while a NaOCl-based cleanser showed significant reduction in 2 microorganisms (3-5 CFU/mL log reduction, P aeruginosa and MRSA).The other PHMB-based cleanser showed a statistically significant 3 log CFU/mL reduction in P aeruginosa. The remaining cleansers showed no statistically significant difference from the saline control. CONCLUSION: Results confirm that there are model-dependent differences in the outcomes of these studies, suggesting the importance of model selection for product screening. The results indicate that 1 PHMB-based cleanser was effective in reducing mature P aeruginosa, MRSA, and C albicans biofilms and that sustained antimicrobial presence was necessary to reduce or eliminate these mature biofilms.


Assuntos
Biofilmes , Detergentes/uso terapêutico , Staphylococcus aureus Resistente à Meticilina/efeitos dos fármacos , Cicatrização/efeitos dos fármacos , Animais , Biguanidas/normas , Biguanidas/uso terapêutico , Detergentes/normas , Modelos Animais de Doenças , Prata/normas , Prata/uso terapêutico , Hipoclorito de Sódio/normas , Hipoclorito de Sódio/uso terapêutico , Suínos/microbiologia
5.
Eur Rev Med Pharmacol Sci ; 24(21): 11432-11439, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33215466

RESUMO

OBJECTIVE: Soap has been used by humankind since ancient times and was probably already known to the Sumerians. It is a fatty acid salt obtained from the reaction of a strong base with a fatty substance of animal (tallow) or plant origin (oil). This reaction is called saponification. Syndets, on the other hand, are much more recent and have been in use for about a century. In the case of liquid syndets, they are mainly alkyl sulphates and their derivatives alkyl ether sulphates while isethionates and sarcosinates are more commonly found in solid syndets. Synthetic soaps and detergents are surfactants and, as such, they have detergent properties. The way soap works accounts for its antimicrobial properties. Thanks to its amphiphilic structure, it is able to interact with the lipid membranes of microorganisms (viruses, bacteria, etc.) and inactivate them. In this coronavirus pandemic period, health authorities worldwide recommend hand washing with soap and water. We therefore wanted to provide a summary of the chemical characteristics and applications of soaps, on the one hand, and synthetic detergents, on the other. Soap is not the only product used for hand hygiene and, given the current situation, alternatives are complex and varied.


Assuntos
Anti-Infecciosos/farmacologia , Betacoronavirus/efeitos dos fármacos , Infecções por Coronavirus/prevenção & controle , Detergentes/farmacologia , Desinfecção das Mãos/métodos , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Sabões/farmacologia , Anti-Infecciosos/química , Anti-Infecciosos/normas , COVID-19 , Controle de Doenças Transmissíveis/métodos , Controle de Doenças Transmissíveis/normas , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/transmissão , Infecções por Coronavirus/virologia , Detergentes/química , Detergentes/normas , Desinfecção das Mãos/normas , Humanos , Pneumonia Viral/epidemiologia , Pneumonia Viral/transmissão , Pneumonia Viral/virologia , SARS-CoV-2 , Sabões/química , Sabões/normas
6.
Int J Food Microbiol ; 323: 108595, 2020 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-32224347

RESUMO

One of the main objectives of the food industry is to guarantee food safety by providing innocuous food products. Therefore, this sector must consider all the possible biotic or abiotic contamination routes from the entry of raw materials to the release of the final product. Currently, one important problem in this regard is the presence of biofilms on food contact surfaces which can transmit pathogens such as L. monocytogenes. In industrial conditions biofilms are found in a mature state, so it is essential that when carrying out removal effectiveness studies in vitro the tests are realized with models that produce these structures in a similarly mature state. The main objective of this study was to evaluate the effectiveness of an alternative treatment (i.e. enzymatic detergent that include natural antimicrobial agents) and a conventional treatment (i.e. chlorinated alkaline) for the elimination of mature L. monocytogenes biofilms. The results showed a cell detachment from the formed mature biofilms with an effectivity of between 74.75%-97.73% and 53.94%-94.02% for the enzymatic treatment and the chlorinated alkaline detergent, respectively. On a qualitative level, it was observed that the dispersion in the structure was much higher for the enzymatic treatment than for the chlorinated alkaline, which continued to show obvious structure integrity. All this leads to the conclusion that treatments with an enzymatic detergent have a significantly greater impact on the removal of mature L. monocytogenes biofilms, although a further disinfection process would be needed, enhancing even more the treatment effectivity. This may imply that the industrial approach to addressing this problem should be modified to include new perspectives that are more effective than traditional ones.


Assuntos
Biofilmes , Detergentes/química , Desinfecção/métodos , Enzimas/metabolismo , Microbiologia de Alimentos/métodos , Indústria de Processamento de Alimentos/métodos , Listeria monocytogenes/fisiologia , Animais , Detergentes/normas , Suínos
7.
Artigo em Inglês | MEDLINE | ID: mdl-31717633

RESUMO

Indoor air quality (IAQ) is one of the main topics in which governments are focusing. In healthcare facilities, several studies have reported data analysis and case studies to improve users' health. Nowadays, although many studies have been conducted related to the biological and physical risks, the chemical risks have been less investigated and only in some specific functional areas of the hospitals. Starting from some systematic reviews and research works, this paper aims to list the best healthy practices for an adequate IAQ in inpatient wards. In particular, the decalogue lists the strategies related to chemical pollution, starting from design and management, with a focus on (a) localization of hospitals and inpatient rooms, (b) hospital room, (c) microclimatic parameters, (d) ventilation systems, (e) materials and finishing, (f) furniture and equipment, (g) cleaning products and activities, (h) maintenance and (i) management activities, and (l) users and workers. The multidisciplinary approach emphasizes the need for interdisciplinary knowledge and skills aimed to find solutions able to protect users' health status. The design and management decision-making, ranging from the adequate choices of construction site and hospital exposure, finishing materials, cleaning and maintenance activities, etc., which can affect the IAQ must be carried out based on scientific research and data analysis.


Assuntos
Poluentes Ocupacionais do Ar/normas , Poluição do Ar em Ambientes Fechados/prevenção & controle , Arquitetura Hospitalar/normas , Hospitais , Detergentes/normas , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Ventilação , Local de Trabalho
8.
Plant Biotechnol J ; 17(6): 1167-1182, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30963679

RESUMO

Chemical catalysts are being replaced by biocatalysts in almost all industrial applications due to environmental concerns, thereby increasing their demand. Enzymes used in current industries are produced in microbial systems or plant seeds. We report here five newly launched leaf-enzyme products and their validation with 15 commercial microbial-enzyme products, for detergent or textile industries. Enzymes expressed in chloroplasts are functional at broad pH/temperature ranges as crude-leaf extracts, while most purified commercial enzymes showed significant loss at alkaline pH or higher temperature, required for broad range commercial applications. In contrast to commercial liquid enzymes requiring cold storage/transportation, chloroplast enzymes as a leaf powder can be stored up to 16 months at ambient temperature without loss of enzyme activity. Chloroplast-derived enzymes are stable in crude-leaf extracts without addition of protease inhibitors. Leaf lipase/mannanase crude extracts removed chocolate or mustard oil stains effectively at both low and high temperatures. Moreover, leaf lipase or mannanase crude-extracts removed stain more efficiently at 70 °C than commercial microbial enzymes (<10% activity). Endoglucanase and exoglucanase in crude leaf extracts removed dye efficiently from denim surface and depilled knitted fabric by removal of horizontal fibre strands. Due to an increased demand for enzymes in the food industry, marker-free lettuce plants expressing lipase or cellobiohydrolase were created for the first time and site-specific transgene integration/homoplasmy was confirmed by Southern blots. Thus, leaf-production platform offers a novel low-cost approach by the elimination of fermentation, purification, concentration, formulation and cold-chain storage/transportation. This is the first report of commercially launched protein products made in leaves and validated with current commercial products.


Assuntos
Detergentes , Lipase , Folhas de Planta , Indústria Têxtil , Cloroplastos/enzimologia , Cloroplastos/genética , Detergentes/normas , Estabilidade Enzimática , Lipase/genética , Lipase/isolamento & purificação , Lipase/metabolismo , Lipase/normas , Folhas de Planta/enzimologia , Folhas de Planta/genética , Temperatura , Indústria Têxtil/métodos , beta-Manosidase/genética , beta-Manosidase/isolamento & purificação , beta-Manosidase/metabolismo , beta-Manosidase/normas
9.
J Clin Apher ; 34(4): 445-449, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30829414

RESUMO

BACKGROUND: Central venous catheters (CVCs) for apheresis procedures require regular locking/flushes to maintain adequate flow rates. Literature comparing locking solutions for apheresis, where the time interval between procedures can be longer than for hemodialysis (many days to weeks), is lacking. In this study, catheter malfunction rates using recombinant tissue plasminogen activator (rt-PA) vs heparin for locking CVC between apheresis procedures were compared. STUDY DESIGN AND METHODS: A retrospective review of 93 extracorporeal photopheresis procedures in 10 patients was performed at our institution. About 1000 U/mL heparin or 2 mg rt-PA was used as the locking solution. Heparin locks were changed at least once per week and rt-PA locks could be left in place for up to 4 weeks. Following these locks, inadequate blood flow noted on accessing CVC and/or during the procedure was scored on as: no issues, some issues, or significant issues. Binary logistic regression was used to evaluate for potential statistical difference in outcomes. Cost analysis was also performed. RESULTS: No statistically significant difference was noted in outcomes between heparin and rt-PA lock (P value = 0.15). Total cost of heparin lock administration ($91-$362.50) was found to be more than rt-PA lock ($76) when more than one flush was needed between procedures. CONCLUSIONS: For apheresis use, rt-PA and heparin CVC locks seem to have similar outcomes in preventing CVC malfunction. The convenience of not needing any flushes between procedures and overall cost of administering fewer locks favors rt-PA use when the interval between procedures is >7 days.


Assuntos
Remoção de Componentes Sanguíneos/instrumentação , Cateteres Venosos Centrais/normas , Heparina/farmacologia , Ativador de Plasminogênio Tecidual/farmacologia , Detergentes/normas , Falha de Equipamento , Heparina/economia , Humanos , Estudos Retrospectivos , Fatores de Tempo , Ativador de Plasminogênio Tecidual/economia
10.
Food Chem Toxicol ; 116(Pt A): 20-24, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29066409

RESUMO

Microbial-based cleaning products (MBCPs) continue to gain popularity in the market as environmentally friendly cleaners. The majority of these products contain spores of various Bacillus species. Although the microorganisms used in MBCPs are subject to regulation in Canada under the Canadian Environmental Protection Act, the products themselves are not. Unlike other types of microbial products such as probiotics and biopesticides, the use, manufacture and quality parameters of MBCPs in Canada and other countries are poorly defined and not specifically subject to any required standards. Due to their complexity and nature, these products feature unique quality challenges. We noted the existing MBCPs we analyzed vary vastly in quality; external microbial contaminants, viability of the spores and the biocompatibility of the ingredients are issues that greatly affect product quality. A proper taxonomic identification of the bacterial species used also seems to be a major challenge for a number of manufacturers. A good understanding of the mechanisms governing these quality challenges and the adoption of good practices for the cultivation, harvesting, formulation, and manufacture of these types of products are essential for achieving high-quality performance standards.


Assuntos
Bactérias/química , Fatores Biológicos/efeitos adversos , Detergentes/química , Indústrias/normas , Bactérias/classificação , Bactérias/genética , Bactérias/metabolismo , Biodegradação Ambiental , Fatores Biológicos/química , Fatores Biológicos/normas , Canadá , Detergentes/efeitos adversos , Detergentes/normas , Controle de Qualidade
11.
Belo Horizonte; s.n; 2018. 92 p. tab, graf, ilus.
Tese em Português | LILACS, BDENF - Enfermagem | ID: biblio-963973

RESUMO

No Brasil, é recomendado que durante a limpeza dos Produtos para Saúde (PPS) o detergente utilizado possua ação enzimática. Embora a Resolução da Diretoria Colegiada nº 55 de 14 de novembro de 2012 da Agência Nacional de Vigilância Sanitária desaconselhe a reutilização desta solução de limpeza, sabe-se que na prática clínica elas são reaproveitadas por diversas vezes para imersão de PPS, como os aparelhos endoscópicos, o que pode comprometer a efetividade da ação do detergente enzimático e com isso a segurança no processamento do PPS. Esta pesquisa objetivou avaliar a carga microbiana presente na solução de detergente enzimático durante sua reutilização na limpeza manual de aparelhos endoscópicos gastrointestinais. Tratou-se de um estudo transversal realizado em um serviço de endoscopia digestiva de um hospital universitário de Belo Horizonte e no Laboratório de Microbiologia Oral e Anaeróbios do ICB/UFMG. A amostra foi composta por 57 aparelhos endoscópicos e 76 alíquotas de solução de detergente enzimáticos coletadas de diversos reusos de 19 diferentes soluções. O material coletado foi agitado em vórtex, acrescido a Caldo Letheem Modificado e submetido a filtração em membrana Millipore® 0,45µm. A membrana foi depositada em Tryptic Soy Ágar para crescimento microbiano. A identificação presuntiva dos micro-organismos foi realizada manualmente considerando-se aspectos morfotintoriais e reações bioquímico/fisiológicas. As variáveis foram descritas utilizando frequências, porcentagens e medidas de tendência central. O projeto foi aprovado pelo Comitê de Ética e Pesquisa da Universidade Federal de Minas Gerais (CAAE ­ 67493417.1.0000.5149). As médias das cargas microbianas na solução de detergente enzimático variaram de 19,9 UFC/mL após primeiro uso, 51,1 UFC/mL após terceiro uso e 67,1UFC/mL após o quinto reuso. Nos canais de ar/água e biópsia houve aumento de micro-organismos Gram negativos ao longo das reutilizações do detergente. Foram recuperados, Enterobacter spp., Escherichia coli, Klebsiella spp., Pseudomonas spp., Staphyloccocus aureus, Staphyloccocus coagulase negativa. Pseudomonas spp. foi o micro-organismo mais identificado em todas as alíquotas coletadas. Verificou-se a importância da escovação do canal de biópsia para correta remoção de micro-organismos. Conclui-se que a reutilização das soluções de detergente enzimático contribuiu para contaminação dos aparelhos endoscópicos com micro-organismos potencialmente patogênicos. Faz-se necessário a reavaliação de protocolos institucionais, no sentido de que seja cumprida a orientação da Anvisa por meio da RDC nº 55 de 14 de novembro de 2012 de que os detergentes enzimáticos não devem ser reutilizados sob perda da eficiência do produto. As características físico químicas dos detergentes enzimáticos devem ser respeitadas pelos serviços de saúde conforme parâmetros estabelecidos pelos fabricantes.(AU)


In Brazil, it is recommended that during the cleaning of Health Products the detergent used has enzymatic action. Although Collegiate Board Resolution No. 55 of November 14, 2012 of the National Agency of Sanitary Surveillance advises against the reuse of this cleaning solution, it is known that in clinical practice they are reused several times for immersion of health products, such a gastrointestinal endoscope, which may compromise the effectiveness of the enzymatic detergent action and thus the safety in the processing. This research aimed to evaluate the microbial load present in the enzymatic detergent solution during its reuse in the manual cleaning of endoscopic gastrointestinal devices. This was a cross-sectional study performed at a gastrointestinal endoscopy service at a university hospital in Belo Horizonte and at the Oral Microbiology and Anaerobic Laboratory of ICB/UFMG. The sample consisted of 57 endoscopes and 76 aliquots of enzymatic detergent solution collected from several replicates of 19 different solutions. The collected material was vortexed, added to Modified Letheem Broth and subjected to Millipore® 0.45 µm membrane filtration. The membrane was deposited in Tryptic Soy Ágar for microbial growth. The identification of the microorganisms was performed manually considering morphotintorial aspects and biochemical/physiological reactions. The variables were described using frequencies, percentages and measures of central tendency. The project was approved by the Ethics and Research Committee of the Federal University of Minas Gerais (CAAE - 67493417.1.0000.5149). The mean values of the microbial loads in the enzymatic detergent solution varied from 19.9 UFC/mL after first use, 51.1 UFC/mL after third use and 67.1 UFC/mL after the fifth reuse. In the air/water and biopsy channels there was an increase of Gram negative microorganisms along the reuse of the detergent. Enterobacter spp., Escherichia coli, Klebsiella spp., Pseudomonas spp., Staphylococcus aureus, Coagulase-negative Staphyloccocus were recovered. Pseudomonas spp. was the most identified microorganism in all aliquots collected. It was verified the importance of brushing the biopsy channel for correct removal of microorganisms. It was concluded that the reuse of enzyme detergent solutions contributed to the contamination of the endoscopes with potentially pathogenic microorganisms. It is necessary to re-evaluate institutional protocols, in order to comply with Anvisa's guidance through RDC nº. 55 of November 14, 2012 that enzymatic detergents should not be reused under loss of product efficiency. The physical characteristics of the enzymatic detergents must be observed by the health services according to the parameters established by the manufacturers.(AU)


Assuntos
Humanos , Controle de Infecções/métodos , Endoscópios/microbiologia , Detergentes/isolamento & purificação , Detergentes/normas , Pseudomonas/isolamento & purificação , Staphylococcus aureus/isolamento & purificação , Contenção de Riscos Biológicos , Dissertação Acadêmica , Enterobacter/isolamento & purificação , Enzimas , Escherichia coli/isolamento & purificação , Klebsiella/isolamento & purificação
12.
Integr Environ Assess Manag ; 13(1): 127-138, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26891423

RESUMO

Cleaning products have long been a focus of efforts to improve sustainability and assure safety for the aquatic environment when disposed of after use. The latter is addressed at ingredient level through environmental risk assessment, including in formal frameworks such as REACH. Nevertheless, in the context of programs to improve overall sustainability, stakeholders demand both environmental safety assurance and progress at product level. Current product-level approaches for aquatic toxicity (e.g., USEtox™, Critical Dilution Volume) can be seen as predominantly hazard-based. The more logical approach would be risk-based, because ecotoxicity is generally threshold-dependent and hazard-based assessment produces conflicts with risk-based learnings. The development of a risk-based approach to assess formulated products is described: the International Association for Soaps, Detergents and Maintenance Products (A.I.S.E.) Charter Environmental Safety Check (ESC), which is consistent with the scientific principles underlying REACH. This is implemented through a simple spreadsheet tool and internal database of ingredient parameters including predicted no-effect concentration (PNEC) and removal rate. A novel feature is applying market volume information for both product types and ingredients to permit a risk-based calculation. To pass the ESC check, the projected environmental safety ratio (PESR) for each ingredient as formulated and dosed (unless cleared by a published risk assessment or exempted as inherently low risk) must be less than 1. The advantages of a risk-based approach are discussed. The strengths and limitations of various possible approaches to standard-setting, product-ranking and driving continuous improvement in respect of potential ecotoxic impacts on the aquatic environment are considered. It is proposed that as ecotoxicity is generally accepted to be threshold-dependent, with no effect below the threshold, the most constructive approach to continuous improvement of sustainability with regard to ecotoxicity is to focus efforts on instances where the safety margins for ingredients as used in specific products are narrow. This necessitates a risk-based approach. Integr Environ Assess Manag 2017;13:127-138. © 2016 The Authors. Integrated Environmental Assessment and Management published by Wiley Periodicals, Inc. on behalf of SETAC.


Assuntos
Detergentes/toxicidade , Poluentes Químicos da Água/toxicidade , Conservação dos Recursos Naturais/métodos , Detergentes/normas , Ecotoxicologia , Monitoramento Ambiental/métodos , Risco , Medição de Risco/métodos , Poluentes Químicos da Água/normas , Poluição Química da Água/estatística & dados numéricos
13.
J Pharm Biomed Anal ; 134: 108-115, 2017 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-27898331

RESUMO

The parameters affecting the recovery of pharmaceutical residues from the surface of stainless steel coupons for quantitative cleaning verification method development have been studied, including active pharmaceutical ingredient (API) level, spiking procedure, API/excipient ratio, analyst-to-analyst variability, inter-day variability, and cleaning procedure of the coupons. The lack of a well-defined procedure that consistently cleaned coupon surface was identified as the major contributor to low and variable recoveries. Assessment of acid, base, and oxidant washes, as well as the order of treatment, showed that a base-water-acid-water-oxidizer-water wash procedure resulted in consistent, accurate spiked recovery (>90%) and reproducible results (Srel≤4%). By applying this cleaning procedure to the previously used coupons that failed the cleaning acceptance criteria, multiple analysts were able to obtain consistent recoveries from day-to-day for different APIs, and API/excipient ratios at various spike levels. We successfully applied our approach for cleaning verification of small molecules (MW<1000Da) as well as large biomolecules (MW up to 50,000Da). Method robustness was greatly influenced by the sample preparation procedure, especially for analyses using total organic carbon (TOC) determination.


Assuntos
Indústria Farmacêutica/normas , Contaminação de Equipamentos/prevenção & controle , Preparações Farmacêuticas/análise , Aço Inoxidável/análise , Aço Inoxidável/normas , Detergentes/administração & dosagem , Detergentes/normas , Indústria Farmacêutica/métodos , Humanos , Preparações Farmacêuticas/síntese química
14.
Nephrol Nurs J ; 43(2): 153-5, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27254970

RESUMO

In an attempt to create a standardized resource for cleansing both non-tunneled and tunneled hemodialysis catheters, it was discovered that all disinfectants are not compatible with all catheters. This article describes the process used to identify best practices for hemodialysis catheter care and steps taken to standardize practice throughout a hospital network. Standardized evidence-based practice preserves the integrity of catheters while allowing nurses to provide quality care to patients.


Assuntos
Infecções Relacionadas a Cateter/prevenção & controle , Cateteres de Demora/normas , Detergentes/normas , Enfermagem em Nefrologia/normas , Guias de Prática Clínica como Assunto , Diálise Renal/instrumentação , Diálise Renal/enfermagem , Infecções Relacionadas a Cateter/enfermagem , Humanos
15.
J Dtsch Dermatol Ges ; 13(6): 594-606, 2015 Jun.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-25997664

RESUMO

Job-related hand dermatitis heads up the list of reported occupational diseases. So-called skin products - understood to mean protective creams, skin cleansers and skin care products - are used for the primary and secondary prevention of job- related hand dermatitis. In the interests of evidence-based medicine, the only preventive measures and/or occupational skin products that should be used are those whose potential uses and efficacy are underpinned by scientific research. To this end, the Arbeitsgemeinschaft für Berufs- und Umweltdermatologie e.V. (Working Group for Occupational and Environmental Dermatology, ABD) of the DDG (German Dermatological Society) and the Deutsche Gesellschaft für Arbeits- und Umweltmedizin (German Society for Occupational and Environmental Medicine, DGAUM) have summed up the latest scientific findings and recommendations in the updated guideline. The benefit of the combined application of protective creams and skin care products in the primary and secondary prevention of work-related contact dermatitis has been widely confirmed by recent clinical-epidemiological studies. The guideline clearly explains the necessity of demonstrating the efficacy of protective creams and cleansing products by means of in vivo methods in the sense of repetitive applications. Transferable standardised testing systems designed to examine the irritation potential and thus the compatibility of occupational skin cleansers and the reduction of irritation by protective skin creams have now been developed and validated by multicentre studies for skin protection creams and cleansers. The status of the current assessment of the safety of occupational skin products is also summarised.


Assuntos
Dermatite Ocupacional/prevenção & controle , Dermatologia/normas , Detergentes/uso terapêutico , Guias de Prática Clínica como Assunto , Higiene da Pele/normas , Creme para a Pele/uso terapêutico , Dermatite Ocupacional/tratamento farmacológico , Detergentes/normas , Alemanha , Medicina do Trabalho/normas , Creme para a Pele/normas
16.
Br Dent J ; 212(10): E16, 2012 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-22627254

RESUMO

AIM: To review physico-chemical data supplied for commercially available detergents marketed for manual and/or ultrasonic cleansing of reusable dental instruments. METHOD: Manufacturers/suppliers of commercially available detergents for manual or ultrasonic cleaning of dental instruments within primary dental care were invited to supply product information. A structured questionnaire requested details on a range of physical and chemical properties for each detergent. RESULTS: Seventeen detergent manufacturers/suppliers, encompassing 31 commercially available detergents were identified. Ten of the 17 manufacturers provided information on 23 (74%) of the detergent formulations. Nine detergents were of neutral pH, ten mild alkalis (pH 7.5-10.5) and four strong alkalis (pH >10.5). Sixteen detergents were recommended for ultrasonic and manual cleaning, four stated ultrasonic use and three manual only. Ten detergents cited enzymatic activity as their main mode of action, but only six manufacturers provided detailed information. Four detergents recommended by manufacturers as suitable for manual washing had a strong alkaline pH (>10.5), presenting chemical hazards to users. Two strong alkaline detergents did not warn users of potential adverse effects of such alkaline solutions (corrosion) upon aluminium containing instruments. Only one detergent had investigated the potential toxicity of detergent residuals remaining on instruments after reprocessing. CONCLUSION: It has proven challenging to collate physico-chemical data on detergents suitable for use in manual and/or ultrasonic cleaning of dental instruments in general dental practice. Standardisation of information on the nature and efficacy of dental detergents in a readily accessible form would be beneficial to dental practice.


Assuntos
Instrumentos Odontológicos , Detergentes/química , Contaminação de Equipamentos/prevenção & controle , Rotulagem de Produtos , Esterilização/métodos , Detergentes/efeitos adversos , Detergentes/normas , Humanos , Indústrias , Ultrassom
17.
Environ Sci Pollut Res Int ; 19(8): 3400-11, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22528988

RESUMO

PURPOSE: The aim of this paper was to develop a new recreational water quality index (RWQI) as a tool to ensure the health of swimmers and to take practical decisions. METHODS: RWQI was elaborated with epidemiological data, and we carried out an exhaustive study of the different guidelines for recreational waters proposed by different organisations around the world. Different parameters were chosen, considering, as a priority, the swimmer's contact and the possibility of ingestion of water during the recreational activity. Furthermore, rating curves were established for pH, chemical oxygen demand, nitrate, phosphate, detergents, enterococci, total coliforms, faecal coliforms and Escherichia coli. RESULTS AND CONCLUSIONS: The index was applied to the data set on water quality of the Potrero de los Funes River (San Luis, Argentina), generated during 2 years (2009-2010). Following the RWQI values classification, most of the Potrero de los Funes water samples fell in the good quality range during the study period.


Assuntos
Microbiologia da Água/normas , Qualidade da Água/normas , Água/química , Água/normas , Argentina , Análise da Demanda Biológica de Oxigênio/normas , Detergentes/normas , Monitoramento Ambiental/métodos , Monitoramento Ambiental/normas , Concentração de Íons de Hidrogênio , Nitratos/normas , Fosfatos/normas , Rios/química , Rios/microbiologia , Natação
18.
J Chromatogr A ; 1218(41): 7275-80, 2011 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-21907992

RESUMO

Enzymes of several classes used in the formulations of cleaning products were characterized by trypsin digestion followed by HPLC with UV detection. A polymeric monolithic column (ProSwift) was used to optimize the separation of both the intact enzymes and their tryptic digests. This column was adequate for the quality control of raw industrial enzyme concentrates. Then, monolithic and microparticulate columns were compared for peptide analysis. Under optimized conditions, the analysis of tryptic digests of enzymes of different classes commonly used in the formulation of cleaning products was carried out. Number of peaks, peak capacity and global resolution were obtained in order to evaluate the chromatographic performance of each column. Particulate shell-core C18 columns (Kinetex, 2.6 µm) showed the best performance, followed by a silica monolithic column (Chromolith RP-18e) and the conventional C18 packings (Gemini, 5 µm or 3 µm). A polymeric monolithic column (ProSwift) gave the worst performances. The proposed method was satisfactorily applied to the characterization of the enzymes present in spiked detergent bases and commercial cleaners.


Assuntos
Cromatografia de Fase Reversa/instrumentação , Detergentes/química , Enzimas/análise , Tripsina/metabolismo , Cromatografia de Fase Reversa/métodos , Detergentes/normas , Enzimas/química , Enzimas/metabolismo , Enzimas/normas , Fragmentos de Peptídeos/análise , Fragmentos de Peptídeos/metabolismo , Reprodutibilidade dos Testes
19.
J Hosp Med ; 6(4): 177-82, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21312328

RESUMO

BACKGROUND: Governmental agencies in the United Kingdom and Scotland have recently instituted guidelines banning physicians' white coats and the wearing of long-sleeved garments to decrease nosocomial transmission of bacteria. OBJECTIVE: Our aim was to compare the degree of bacterial and methicillin-resistant Staphylococcus aureus contamination of physicians' white coats with that of newly laundered, standardized short-sleeved uniforms after an 8-hour workday and to determine the rate at which bacterial contamination of the uniform ensued. DESIGN: The design was a prospective, randomized controlled trial. SETTING: The setting was a university-affiliated public safety-net hospital. PARTICIPANTS: One hundred residents and hospitalists on an internal medicine service participated. INTERVENTION: Subjects wore either a physician's white coat or a newly laundered short-sleeved uniform. MEASUREMENTS: Bacterial colony count and the frequency with which methicillin-resistant Staphylococcus aureus was cultured from both garments over time were measured. RESULTS: No statistically significant differences were found in bacterial or methicillin-resistant Staphylococcus aureus contamination of physicians' white coats compared with newly laundered short-sleeved uniforms or in contamination of the skin at the wrists of physicians wearing either garment. Colony counts of newly laundered uniforms were essentially zero, but after 3 hours of wear they were nearly 50% of those counted at 8 hours. CONCLUSIONS: Bacterial contamination occurs within hours after donning newly laundered short-sleeved uniforms. After 8 hours of wear, no difference was observed in the degree of contamination of uniforms versus infrequently laundered white coats. Our data do not support discarding long-sleeved white coats for short-sleeved uniforms that are changed on a daily basis.


Assuntos
Carga Bacteriana/normas , Vestuário/normas , Detergentes/normas , Staphylococcus aureus Resistente à Meticilina/isolamento & purificação , Médicos/normas , Carga Bacteriana/métodos , Infecção Hospitalar/microbiologia , Infecção Hospitalar/prevenção & controle , Contaminação de Equipamentos/prevenção & controle , Humanos , Estudos Prospectivos , Escócia , Fatores de Tempo , Reino Unido
20.
Drug Alcohol Rev ; 29(4): 413-9, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20636658

RESUMO

INTRODUCTION AND AIMS: Cleaning needles/syringes is an important second-line harm reduction strategy, yet there is limited information on practices employed by people who inject drugs in Australia. This study attempts to identify and assess cleaning practices in terms of the techniques involved and the social contexts in which cleaning takes place. DESIGN AND METHODS: As part of an exploratory qualitative study in south-west Sydney, in-depth interviews and simulated cleaning exercises were conducted with 12 people who inject drugs. Interviews were digitally recorded and transcribed verbatim. Open coding was used to inductively classify data into themes, and data were examined for patterns and variations in the relationships within and between themes. RESULTS: Data indicate that cleaning and reuse of needles/syringes was common in this small sample. The most frequently utilised reagent was cool water. While all participants reported cleaning and reusing only their own equipment, none of the techniques demonstrated would have been sufficient to deactivate human immunodeficiency virus or hepatitis C virus. DISCUSSION AND CONCLUSIONS: Results suggest that even where cleaning of needles and syringes is widespread, people who inject drugs may not engage in efficacious cleaning. The combination of the complexity of current cleaning messages and a lack of accurate information about efficacious techniques are likely to contribute to poor cleaning practice. Australia could benefit from the development of a nationally consistent cleaning message; however, the evidence would suggest that this would need to be accompanied by strategies designed to simplify and disseminate this information in order to increase the uptake of efficacious cleaning methods by people who inject drugs.


Assuntos
Detergentes/normas , Redução do Dano , Uso Comum de Agulhas e Seringas/efeitos adversos , Agulhas/normas , Abuso de Substâncias por Via Intravenosa/epidemiologia , Seringas/normas , Adulto , Desinfecção/métodos , Feminino , Hepatite C/etiologia , Hepatite C/prevenção & controle , Humanos , Entrevistas como Assunto , Masculino , New South Wales/epidemiologia , Abuso de Substâncias por Via Intravenosa/complicações , Água/normas , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...