Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
1.
Sensors (Basel) ; 19(24)2019 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-31817537

RESUMO

Electronic tongue systems equipped with cross-sensitive potentiometric sensors have been applied to pharmaceutical analysis, due to the possibility of various applications and developing new formulations. Many studies already proved the complementarity between the electronic tongue and classical analysis such as dissolution tests indicated by Pharmacopeias. However, as a new approach to study pharmaceuticals, electronic tongues lack strict testing protocols and specification limits; therefore, their results can be improperly interpreted and inconsistent with the reference studies. Therefore, all aspects of the development, measurement conditions, data analysis, and interpretation of electronic tongue results were discussed in this overview. The critical evaluation of the effectiveness and reliability of constructed devices may be helpful for a better understanding of electronic tongue systems development and for providing strict testing protocols.


Assuntos
Preparações Farmacêuticas/análise , Potenciometria/métodos , Dipirona/análise , Composição de Medicamentos , Nariz Eletrônico , Eletrodos Seletivos de Íons , Potenciometria/instrumentação , Análise de Componente Principal , Pseudoefedrina/análise , Temperatura
2.
Eur J Pharm Sci ; 127: 252-260, 2019 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-30391402

RESUMO

The need for pharmacokinetic knowledge about antibiotics directly at the site of infection, typically the interstitial space fluid (ISF) of tissues, is gaining acceptance for effective and safe treatment. One option to acquire such data is the microdialysis technique employing a catheter with a semipermeable membrane inserted directly in the ISF. A prerequisite is catheter calibration, e.g. via retrodialysis, yielding a conversion factor from measured to true ISF concentrations, termed relative recovery. This value can be influenced by various factors. The present investigation assessed the impact of three of them on relative recovery using seven drugs: (I) drug combinations/order, (II) air in the microdialysis system, (III) flow rate changes inherent when using common in vivo microdialysis pumps. All experiments were performed in a standardised in vitro microdialysis system. (I) Relative recovery of single antibiotics (linezolid, meropenem, cefazolin, metronidazole, tigecycline) was determined in microdialysis and retrodialysis settings and compared with values using either antibiotic or antibiotic+analgesic (acetaminophen and metamizole) combinations or single drugs with reversed microdialysis order. For assessing these factors for lower relative recovery values (as in in vivo), these were mimicked by increasing the flow rate for linezolid. (II) For the impact of air, linezolid relative recovery of freshly carbonated solutions was compared to degassed ones in microdialysis and retrodialysis settings. For each condition in (I) and (II), summary statistics of relative recovery were calculated and for the impact of the factors a linear mixed-effect model developed. (III) From samples taken during an automatic flush sequence (15 µL/min) of an in vivo pump and afterwards switching to the flow rate of 1 and 2 µL/min for 120 min, the time necessary for relative recovery to reach equilibrium was determined. (I) High relative recovery values (flow rate 2 µL/min: ≥84%; flow rate 5 µL/min: ≥65%) were observed for all investigated single drugs. Intra- and intercatheter variability ranged from 0.3%-11% and 3%-25%, respectively. Based on these values and on the statistical model, the impact of drug combination versus single drug as well as of reversed order was small with changes in relative recovery of smaller equal 9%. (II) Compared to degassed solutions, relative recovery in carbonated solutions was 23% and 19% lower (relative reduction) in the microdialysis and retrodialysis setting, respectively, with increased intercatheter variability (up to 37%). (III) As expected, relative recovery increased after the flush sequence and was constant 10-15 min after the switch to the typical 1 and 2 µL/min flow rate. Given the intercatheter variability, combinations and the order of drugs showed minor but clinically negligible impact on relative recovery. In contrast, air in the microdialysis catheter/system caused falsely low and inconsistent relative recovery values and must be avoided when performing a trial. Also changes in flow rate at the end of pump flush sequence impacted relative recovery. Hence, a sufficient equilibration time of 10-15 min prior to sampling should be implemented in sampling protocols. In vitro microdialysis presents a highly valuable complementary platform to clinical microdialysis studies impacting the design, sampling schedule and data analysis of such trials to gain knowledge of target-site pharmacokinetics for contributing to better informed decisions in the individual patient/special populations in future.


Assuntos
Analgésicos/análise , Antibacterianos/análise , Microdiálise , Acetaminofen/análise , Catéteres , Dipirona/análise , Combinação de Medicamentos
3.
Anal Chim Acta ; 1033: 49-57, 2018 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-30172331

RESUMO

This work presents potential applications of low-cost fused deposition modeling 3D-printers to fabricate multiuse 3D-printed electrochemical cells for flow or batch measurements as well as the 3D-printing of electrochemical sensing platforms. Electrochemical cells and sensors were printed with acrylonitrile butadiene styrene (ABS) and conductive graphene-doped polylactic acid (G-PLA) filaments, respectively. The overall printing operation time and estimated cost per cell were 6 h and $ 6.00, respectively, while the sensors were printed within minutes (16 sensor strips of 1 × 2 cm in 10 min at a cost of $ 1.00 each sensor). The cell performance is demonstrated for the amperometric detection of tert-butylhydroquinone, dipyrone, dopamine and diclofenac by flow-injection analysis (FIA) and batch-injection analysis (BIA) using different working electrodes, including the proposed 3D-printed sensor, which presented comparable electroanalytical performance with other carbon-based electrodes (LOD of 0.1 µmol L-1 for dopamine). Raman spectroscopy and scanning electron microscopy of the 3D-printed sensor indicated the presence of graphene nanoribbons within the polymeric matrix. Electrochemical impedance spectroscopy and heterogeneous electron transfer constants (k0) for the redox probe Ru(NH3)6+3 revealed that a glassy-carbon electrode presented faster electron transfer rates than the 3D-printed sensor; however, the latter presented lower LOD values for dopamine and catechol probably due to oxygenated functional groups at the G-PLA surface.


Assuntos
Técnicas Eletroquímicas , Análise de Injeção de Fluxo , Impressão Tridimensional , Diclofenaco/análise , Dipirona/análise , Dopamina/análise , Transporte de Elétrons , Hidroquinonas/análise , Microscopia Eletrônica de Varredura , Análise Espectral Raman , Propriedades de Superfície
4.
J Vet Pharmacol Ther ; 41(5): 699-705, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29943417

RESUMO

Metamizole (dipyrone, MET) is a nonopioid analgesic drug commonly used in human and veterinary medicine. The aim of this study was to assess two major active metabolites of MET, 4-methylaminoantipyrin (MAA) and 4-aminoantipyrin (AA), in goat plasma after intravenous (IV) and intramuscular (IM) administration. In addition, metabolite concentration in milk was monitored after IM injection. Six healthy female goats received MET at a dose of 25 mg/kg by IV and IM routes in a crossover design study. The blood and milk samples were analyzed using HPLC coupled with ultraviolet detector and the plasma vs concentration curves analyzed by a noncompartmental model. In the goat, the MET rapidly converted into MAA and the mean maximum concentration was 183.97 µg/ml (at 0.08 hr) and 51.94 µg/ml (at 0.70 hr) after IV and IM administration, respectively. The area under the curve and mean residual time values were higher in the IM than the IV administered goats. The average concentration of AA was lower than MAA in both groups. Over 1 µg/ml of MAA was found in the milk (at 48 hr) after MET IM administration. In conclusion, IM is considered to be a better administration route in terms of its complete absorption with long persistence in the plasma. However, this therapeutic option should be considered in light of the likelihood of there being milk residue.


Assuntos
Analgésicos/farmacocinética , Dipirona/farmacocinética , Resíduos de Drogas/análise , Leite/química , Ampirona/análise , Analgésicos/análise , Animais , Antipirina/análogos & derivados , Antipirina/análise , Dipirona/análise , Feminino , Cabras/metabolismo , Injeções Intramusculares/veterinária , Injeções Intravenosas/veterinária
5.
Forensic Sci Int ; 270: 185-192, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27823839

RESUMO

Dipyrone is an analgesic and antipyretic drug that is sometimes encountered as an adulterant in illicit drug samples, particularly illicit fentanyl containing samples. It undergoes thermal decomposition to aminopyrine and 4-methylaminoantipyrine during analysis via gas chromatography (GC-FID) and gas chromatography-mass spectrometry (GC-MS). During analysis via high pressure liquid chromatography (HPLC) and high pressure liquid chromatography-mass spectrometry (HPLC-MS), it undergoes hydrolytic decomposition solely to 4-methylaminoantipyrine. Given that mass spectrometry is a widely used confirmatory analytical technique, these instabilities present challenges for the forensic chemist seeking to confirm the presence of dipyrone. Studies were conducted to determine rigorous confirmative protocols for the identification of dipyrone in multicomponent illicit drug samples.


Assuntos
Dipirona/análise , Contaminação de Medicamentos , Drogas Ilícitas/química , Cromatografia Líquida de Alta Pressão , Fentanila/química , Toxicologia Forense , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Espectrometria de Massas por Ionização por Electrospray
6.
Artigo em Inglês | MEDLINE | ID: mdl-27268755

RESUMO

A reliable and simple method for the detection and quantification of residues of 14 non-steroidal anti-inflammatory drugs and a metamizole metabolite in swine muscle was developed using liquid chromatography-electrospray ionisation-tandem mass spectrometry (LC-ESI-MS/MS). The samples were extracted with acetonitrile (ACN) in solid-liquid extraction followed by a low-temperature partitioning (LLE-LTP) process at -20 ± 2°C. After evaporation to dryness, the residue was reconstituted with hexane and a mixture of water:acetonitrile (1:1). LC separation was achieved on a reversed-phase (RP18) column with gradient elution using water (phase A) and ACN (phase B) both containing 1 mmol l(-)(1) ammonium acetate (NH4COO) with 0.025% acetic acid. Analysis was carried out on a triple-quadrupole tandem mass spectrometer (LC-MS/MS) in multiple reaction monitoring mode using an electrospray interface in negative and positive mode in a single run. Method validation was performed according to the criteria of Commission Decision No. 2002/657/EC. The matrix effect and linearity were evaluated. Decision limit (CCα), detection capability (CCß), accuracy and repeatability of the method are also reported. The proposed method proved to be simple, easy and adequate for high-throughput analysis and was applied to routine analysis by the Brazilian Ministry of Agriculture, Livestock and Food Supply.


Assuntos
Anti-Inflamatórios não Esteroides/análise , Cromatografia Líquida/métodos , Dipirona/análise , Resíduos de Drogas/análise , Carne/análise , Espectrometria de Massas em Tandem/métodos , Acetonitrilas/química , Animais , Anti-Inflamatórios não Esteroides/metabolismo , Cromatografia Líquida/normas , Dipirona/análogos & derivados , Dipirona/metabolismo , Resíduos de Drogas/metabolismo , Limite de Detecção , Extração Líquido-Líquido/métodos , Músculo Esquelético/química , Reprodutibilidade dos Testes , Suínos , Espectrometria de Massas em Tandem/normas , Água/química
7.
J Chromatogr A ; 1327: 149-54, 2014 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-24411092

RESUMO

Capillary electrophoresis with capacitively coupled contactless conductivity detection (CE-C(4)D) was used for fast, simultaneous determination of dipyrone (DIP), caffeine (CAF), and acetylsalicylic acid (ASA). In the same run and in less than 1min, the degradation products from DIP and ASA were also detected. In addition, the usage of the CE-C(4)D system allowed, for the first time, the detection of methylamine as a degradation product of DIP. Capillary electrophoresis with electrospray mass spectrometry experiments were carried out in order to confirm the formation of methylamine. The limits of detection by CE-C(4)D were 5, 5, and 6µmolL(-1) for CAF, DIP, and ASA, respectively. The proposed method was applied to the analysis of these compounds in pharmaceutical formulations with similar results to those achieved by HPLC (p<0.05).


Assuntos
Aspirina/análise , Cafeína/análise , Dipirona/análise , Cromatografia Líquida de Alta Pressão , Condutividade Elétrica , Eletroforese Capilar/métodos , Hidrólise , Metilaminas/análise
8.
J Pharm Biomed Anal ; 90: 58-63, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24333705

RESUMO

Liquid chromatography quadrupole time-of-flight spectrometry (LC-Q-TOF-MS), equipped with electrospray ionization (ESI), was developed for the determination of the main metabolites of dipyrone - 4-aminoantipyrine (4-AA), 4-acetylaminoantipyrine (4-AAA), 4-formylaminoantipyrine (4-FAA) and 4-methylaminoantipyrine (4-MAA) in communal wastewater after reversed-phase solid phase extraction (SPE) in the low to several µg/l concentration range. Samples originated from conventional wastewater treatment plant (WWTP) using activated sewage sludge as well as from a pilot-scale WWTP operating in mixed mode (activated sewage sludge and cascade biofilms reactors with biofilms growing on fix beds and roots of greenhouse plants). Results of the present study confirmed the outcomes of our previous report according to which, 4-FAA was the most persistent metabolite, while 4-AAA and 4-MAA could be determined in the highest and lowest concentration, respectively. Moreover, the study of intraday variation of the concentration of these metabolites revealed that the concentration of 4-AA, 4-AAA and 4-FAA registered a 46%-75% increase in the samples collected at noon compared to those collected at 6 AM. Chlorination did not affect considerably the removal efficiency (about 15%) of these metabolites in samples collected for 3 months consecutively before and after disinfection. Both wastewater treatment techniques efficiently removed 4-AAA (between 80 and 96%). However, in the summer season, the removal efficiency of conventional WWTP using open-air aerated tanks is lower by 30%, (on average) than in the cold season. The concentration of the investigated metabolites showed increased concentrations in the winter season confirming the intake habits of the population from this popular analgesic and antipyretic drug.


Assuntos
Cromatografia Líquida/métodos , Dipirona/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Águas Residuárias/análise , Analgésicos/análise , Analgésicos/metabolismo , Biofilmes , Reatores Biológicos , Dipirona/metabolismo , Projetos Piloto , Estações do Ano , Extração em Fase Sólida/métodos , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/metabolismo
9.
Bioanalysis ; 5(21): 2631-45, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24180504

RESUMO

BACKGROUND: After oral administration dipyrone is rapidly hydrolyzed to 4-methylaminoantipyrine, which is absorbed and further metabolized to 4-formylaminoantipyrine and to 4-aminoantipyrine, which is acetylated by a polymorphic N-acetyltransferase system to 4-acetylaminoantipyrine. To evaluate the presence of dipyrone metabolites in different rat matrices after intraperitoneal administration, an analytical method was developed and validated. METHODOLOGY: The four main dipyrone metabolites were extracted from plasma, cerebrospinal fluid and hypothalamus samples by LLE prior to LC-MS/MS. RESULTS: Standard calibration graphs for all metabolites were linear (r > 0.99). The intra- and inter-day precision and accuracy values were both inferior to 15%. CONCLUSION: This method is simple and specific for studying dipyrone metabolites after intraperitoneal administration.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Dipirona/análise , Hipotálamo/química , Espectrometria de Massas em Tandem/métodos , Animais , Dipirona/sangue , Dipirona/líquido cefalorraquidiano , Dipirona/metabolismo , Hipotálamo/metabolismo , Masculino , Ratos , Ratos Wistar
10.
Artigo em Inglês | MEDLINE | ID: mdl-23697889

RESUMO

Metamizole is a pyrazolone non-steroidal anti-inflammatory drug allowed for use in food-producing animals. According to Council Directive 96/23, residues of this drug have to be monitored because of the potential risk to consumers' health. Metamizole is hydrolysed to its marker residue 4-methylaminoantypyrine.This compound is further metabolised to three main metabolites: 4-formylaminoantipyrine, 4-aminoantipyrine and 4-acetylaminoantipyrine. The MRL of 4-methylaminoantipyrine in animal tissues is 100 µg kg(-1). Considering the above points, a method for the detection of four metamizole metabolites in bovine muscles was developed. Analytes were extracted from muscle by a mixture of acetonitrile and sodium acetate buffer. After centrifugation, the supernatant was passed through alumina cartridges, diluted with mobile phase and analysed by using LC-MS/MS. Four metamizole metabolites were separated on a C8 column in 23 min with a gradient of methanol:acetonitrile:ammonium formate solution and analysed by using positive ionisation. Validation of the method indicated a within-laboratory reproducibility in the range of 7-30% and recovery in the range of 45-95%. The method fulfils the criteria for confirmatory methods and, thanks to its labour efficiency, may also be used for screening purposes.


Assuntos
Anti-Inflamatórios não Esteroides/análise , Cromatografia Líquida/métodos , Dipirona/análise , Resíduos de Drogas/análise , Músculos/química , Espectrometria de Massas em Tandem/métodos , Animais , Bovinos
11.
J Mass Spectrom ; 47(8): 1040-6, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22899513

RESUMO

Pharmaceuticals are emerging contaminants of increasing concern because of their presence in the aquatic environment and potential to reach drinking-water sources. After human and/or veterinary consumption, pharmaceuticals can be excreted in unchanged form, as the parent compound, and/or as free or conjugated metabolites. Determination of most pharmaceuticals and metabolites in the environment is commonly made by liquid chromatography (LC) coupled to mass spectrometry (MS). LC coupled to tandem MS is the technique of choice nowadays in this field. The acquisition of two selected reaction monitoring (SRM) transitions together with the retention time is the most widely accepted criterion for a safe quantification and confirmation assay. However, scarce attention is normally paid to the selectivity of the selected transitions as well as to the chromatographic separation. In this work, the importance of full spectrum acquisition high-resolution MS data using a hybrid quadrupole time-of-flight analyser and/or a suitable chromatographic separation (to reduce the possibility of co-eluting interferences) is highlighted when investigating pharmaceutical metabolites that share common fragment ions. For this purpose, the analytical challenge associated to the determination of metabolites of the widely used analgesic dipyrone (also known as metamizol) in urban wastewater is discussed. Examples are given on the possibilities of reporting false positives of dypirone metabolites by LC-MS/MS under SRM mode due to a wrong assignment of identity of the compounds detected.


Assuntos
Cromatografia Líquida/métodos , Dipirona/análise , Preparações Farmacêuticas/análise , Espectrometria de Massas em Tandem/métodos , Águas Residuárias/química , Dipirona/química , Modelos Químicos , Preparações Farmacêuticas/química , Água/química , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/química
12.
Talanta ; 92: 84-6, 2012 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-22385812

RESUMO

The present paper proposes an analytical method for fast near-infrared (NIR) determination of dipyrone in injectable formulations with a nominal content of 50.0%mv(-1) without violation of the ampoule. For this purpose, two multivariate calibration methods are evaluated, namely Partial-Least-Squares (PLS) and Multiple Linear Regression (MLR) with variable selection by the Successive Projections Algorithm (SPA). The resulting models comprised four latent variables (PLS) and five spectral variables (MLR-SPA). Appropriate predictions were obtained in both cases, with RMSEP values of 0.39 (PLS) and 0.35%mv(-1) (MLR-SPA) and correlation coefficients of 0.9970 (PLS) and 0.9975 (MLR-SPA) for a calibration range of 40-60%mv(-1). No systematic error was observed and no significant differences were found between the predicted and reference values, according to a paired t-test at 95% confidence level.


Assuntos
Dipirona/análise , Software , Algoritmos , Calibragem , Humanos , Injeções , Análise de Regressão , Espectroscopia de Luz Próxima ao Infravermelho
13.
Luminescence ; 27(1): 45-50, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-21678544

RESUMO

A rapid, economic and sensitive chemiluminescent method involving flow-injection analysis was developed for the determination of dipyrone in pharmaceutical preparations. The method is based on the chemiluminescent reaction between quinolinic hydrazide and hydrogen peroxide in a strongly alkaline medium, in which vanadium(IV) acts as a catalyst. Principal chemical and physical variables involved in the flow-injection system were optimized using a modified simplex method. The variations in the quantum yield observed when dipyrone was present in the reaction medium were used to determine the concentration of this compound. The proposed method requires no preconcentration steps and reliably quantifies dipyrone over the linear range 1-50 µg/mL. In addition, a sample throughput of 85 samples/h is possible.


Assuntos
Dipirona/análise , Análise de Injeção de Fluxo/métodos , Medições Luminescentes/métodos , Preparações Farmacêuticas/análise , Anti-Inflamatórios não Esteroides , Hidrazinas/química , Peróxido de Hidrogênio/química , Vanádio/química
14.
Talanta ; 85(4): 2067-73, 2011 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-21872059

RESUMO

A biomimetic sensor for the determination of dipyrone was prepared by modifying carbon paste with cobalt phthalocyanine (CoPc), and used as an amperometric detector in a flow injection analysis (FIA) system. The results of cyclic voltammetry experiments suggested that CoPc behaved as a biomimetic catalyst in the electrocatalytic oxidation of dipyrone, which involved the transfer of one electron. The optimized FIA procedure employed a flow rate of 1.5 mL min(-1), a 75 µL sample loop, a 0.1 mol L(-1) phosphate buffer carrier solution at pH 7.0 and amperometric detection at a potential of 0.3 V vs. Ag/AgCl. Under these conditions, the proposed method showed a linear response for dipyrone concentrations in the range 5.0 × 10(-6)-6.3 × 10(-3) mol L(-1). Selectivity and interference studies were carried out in order to validate the system for use with pharmaceutical and environmental samples. In addition to being environmentally friendly, the proposed method is a sensitive and selective analytical tool for the determination of dipyrone.


Assuntos
Materiais Biomiméticos/química , Dipirona/análise , Eletroquímica/métodos , Análise de Injeção de Fluxo/métodos , Indóis/química , Compostos Organometálicos/química , Catálise , Sistema Enzimático do Citocromo P-450/metabolismo , Eletroquímica/economia , Análise de Injeção de Fluxo/economia , Fatores de Tempo
15.
Comb Chem High Throughput Screen ; 13(7): 590-8, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20402639

RESUMO

A rapid electrochemical procedure for the determination of dipyrone was successfully developed at a carbon nanotube modified graphite-epoxy resin composite (GrEC) electrode. The composite electrode was used as support on which multi-walled carbon nanotubes (MWCNT) were immobilised by 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide together with N-hydroxysuccinimide (EDC-NHS) in a chitosan (Chit) matrix. The electrochemical behaviour of dipyrone at this electrode in different buffer electrolytes with pH values between 5.0 and 8.0 was explored using cyclic voltammetry, differential pulse voltammetry, and electrochemical impedance spectroscopy, and comparison with a conventional glassy carbon electrode was made. Dipyrone was best determined by differential pulse voltammetry with a low limit of detection of 1.4 microM. Application to commercial samples was demonstrated.


Assuntos
Quitosana/química , Dipirona/análise , Compostos de Epóxi/química , Grafite/química , Nanotubos de Carbono/química , Eletroquímica , Eletrodos , Ensaios de Triagem em Larga Escala/métodos , Estrutura Molecular , Propriedades de Superfície , Fatores de Tempo
16.
J Chromatogr Sci ; 47(3): 231-7, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19298711

RESUMO

A high-performance liquid chromatography-diode array detection method was developed and validated to simultaneously determine tramadol (TMD), metamizole (MTZ), ropivacaine (RPV), and bupivacaine (BPV) in the presence of 4-methylaminoantypirine (4-MAA), the metabolite of MTZ, in analgesic mixtures samples used in Patient Controlled Analgesia (PCA). Chromatographic separation is achieved with a C-18 column using a mixture of ACN-methanol-water adjusted to pH 3.0 with NaH(2)PO(4) 0.05M (10:25:65 v/v) in an isocratic mobile phase at a flow rate of 0.8 mL/min. 0.5 mg/mL of Na(2)SO(3) in the water of the mobile phase was necessary to prevent the fast MTZ hydrolysis process to 4-MAA. Ultraviolet-diode array detection was used and chromatograms were registered at the wavelength of 230 nm. The method was linear in the range of 2.2-80.0 mg/L for TMD, 4.1-140.0 mg/L for MTZ, 2.3-40.0 mg/L for RPV, and 2.9-40.0 mg/L for BPV. Validation of the method was made in terms of accuracy, intra- and interday precision, as well as quantification and detection limits. The hydrolysis of MTZ to 4-MAA was studied and verified by mass spectrometry. The developed method was used successfully to evaluate the chemical stability of binary analgesic TMD mixtures with MTZ, RPV, or BPV. The mixtures were tested at standard concentrations used in PCA and in different storage conditions. When mixtures contained MTZ, a chromatographic peak from the metabolite 4-MAA was always detected in the chromatograms.


Assuntos
Amidas/análise , Analgésicos/análise , Bupivacaína/análise , Cromatografia Líquida de Alta Pressão/métodos , Dipirona/análise , Tramadol/análise , Analgésicos Opioides/análise , Anestésicos Locais/análise , Anti-Inflamatórios não Esteroides/análise , Estabilidade de Medicamentos , Hidrólise , Controle de Qualidade , Reprodutibilidade dos Testes , Ropivacaina , Sensibilidade e Especificidade
18.
Chemosphere ; 71(9): 1754-64, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18164746

RESUMO

The occurrence and fate of residues from the therapeutic use of the non-steroidal anti-inflammatory drug metamizole have been studied in investigations of sewage effluents from a military hospital, municipal sewers and a sewage treatment plant (STP) in Berlin, Germany. The loads of the metabolites aminoantipyrin (AA), 4-acetylaminoantipyrin (AAA) and 4-formyl-aminoantipyrin (FAA), rapidly formed after the application of metamizole, were predicted from pharmacokinetic data and based on the evaluation of extensive data sets of on the administration in hospitals and private households. In parallel, the actual concentrations were measured within three field trials. For the military hospital, the estimated average annual discharges of AA/AAA and FAA were 10.5 and 3.2 kg, respectively. For the STP, annual loads of 333 and 133 kg were determined for AA/AAA and FAA, respectively. During sewage treatment, an average decrease of 26% of the loads was measured for AA/AAA whereas no changes were observed for FAA. Generally, the prediction of the loads resulted in an overestimation of the residue levels compared to those measured in the respective sewers. Thus, modeling of predicted loads or concentrations alone will not be sufficient for a realistic assessment. Concerns for human or other mammals' health are not expected from the occurrence of metamizole residues in the aquatic system measured at concentrations up to 7 microg l(-1) in STP effluents. However, a rest of uncertainty remains as it was not possible to derive a no observed effect level for the induction of rare but potentially fatal toxicological side effects reported for metamizole.


Assuntos
Anti-Inflamatórios não Esteroides/análise , Dipirona/análise , Hospitais Militares , Resíduos Industriais , Poluentes Químicos da Água/análise , Anti-Inflamatórios não Esteroides/farmacocinética , Disponibilidade Biológica , Dipirona/farmacocinética , Poluentes Químicos da Água/farmacocinética
19.
Anal Sci ; 23(12): 1383-9, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18071223

RESUMO

A sensitive flow-injection (FI) procedure with spectrophotometric detection in a micellar medium is proposed for the determination of novalgin. The method is based on the instantaneous formation of a red-orange product (lambda(max) = 510 nm) after the reaction between novalgin and p-dimethylaminocinnamaldehyde (p-DAC) in a dilute acid medium. The sensitivity of this reaction was increased by a factor of 5.6 in the presence of sodium dodecyl sulfate (SDS). Experimental design methodologies were used to optimize the chemical and FI variables. The calibration curve was linear in the range of 1.45 x 10(-6) to 2.90 x 10(-5) mol L(-1) with an excellent correlation coefficient (r = 0.9999). The detection limit was 1.31 x 10(-7) mol L(-1) (n = 20, RSD = 2.0%). No interferences were observed from the common excipients. The results obtained by the proposed method were favorably compared with those given by the iodometric reference method at 95% confidence level.


Assuntos
Anti-Inflamatórios não Esteroides/análise , Dipirona/análise , Análise de Injeção de Fluxo , Indicadores e Reagentes , Micelas , Soluções Farmacêuticas , Padrões de Referência , Reprodutibilidade dos Testes , Espectrofotometria Ultravioleta , Comprimidos
20.
J Chromatogr Sci ; 45(5): 251-5, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17555632

RESUMO

A new high-throughput method is developed to quantify caffeine, ergotamine, and metamizol in a solid pharmaceutical formulation. After dissolution, the compounds are separated on silica gel 60 F(254) high-performance thin-layer chromatography (HPTLC) plates with ethyl acetate-methanol-ammonia 90:15:1 (v/v/v) as the mobile phase. Detection is performed by UV absorption at 274 nm for caffeine and metamizol, and by fluorescence at 313 /> 340 nm for ergotamine. Calibrations are linear or polynomial with determination coefficients (R(2)) >or= 0.9986. Recoveries of the three compounds are between 95% and 102% at three different concentration levels. Repeatability [relative standard deviation (RSD)] of all substances in the matrix is between +/- 0.9% and +/- 1.7%. Intermediate precision (RSD) of the three compounds range from +/- 2.0% to +/- 3.1%. Mass confirmation is performed by a single quadrupole mass spectrometry in positive electrospray ionization full scan mode for caffeine and ergotamine and in negative mode for metamizol. The results proved that this method is a simple and reliable alternative for routine analysis.


Assuntos
Cafeína/análise , Cromatografia em Camada Fina/métodos , Dipirona/análise , Ergotamina/análise , Preparações Farmacêuticas/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrofotometria Ultravioleta/métodos , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...