Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 607
Filtrar
1.
J Am Heart Assoc ; 13(9): e034249, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38639354

RESUMO

This comprehensive review explores the incidence, pathophysiology, and management of atrial fibrillation (AF) following percutaneous closure of patent foramen ovale (PFO). Although AF is considered a common adverse event post PFO closure, its incidence, estimated at <5%, varies based on monitoring methods. The review delves into the challenging task of precisely estimating AF incidence, given subclinical AF and diverse diagnostic approaches. Notably, a temporal pattern emerges, with peak incidence around the 14th day after closure and a subsequent decline after the 45th day, mimicking general population AF trends. The pathophysiological mechanisms behind post PFO closure AF remain elusive, with proposed factors including local irritation, device-related interference, tissue stretch, and nickel hypersensitivity. Management considerations encompass rhythm control, with flecainide showing promise, and anticoagulation tailored to individual risk profiles. The authors advocate for a personalized approach, weighing factors like age, comorbidities, and device characteristics. Notably, postclosure AF is generally considered benign, often resolving spontaneously within 45 days, minimizing thromboembolic risks. Further studies are required to refine understanding and provide evidence-based guidelines.


Assuntos
Fibrilação Atrial , Forame Oval Patente , Humanos , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/etiologia , Fibrilação Atrial/terapia , Fibrilação Atrial/diagnóstico , Forame Oval Patente/epidemiologia , Forame Oval Patente/fisiopatologia , Forame Oval Patente/terapia , Forame Oval Patente/complicações , Incidência , Cateterismo Cardíaco/efeitos adversos , Fatores de Risco , Dispositivo para Oclusão Septal/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia
3.
Turk Kardiyol Dern Ars ; 52(2): 149-152, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38465527

RESUMO

Transcatheter closure of muscular ventricular septal defects (VSD) remains a safe and effective method with low complication rates. However, device migration can pose a significant challenge to interventional cardiologists due to potential mortal consequences. A 21-year-old female presented to our clinic with exertional dyspnea and was diagnosed with a muscular VSD. The defect was percutaneously closed using an Amplatzer occluder device. On the first post-procedural day, the patient experienced repeated episodes of coughing and mild hemoptysis. Imaging revealed migration of the VSD occluder device to the right pulmonary artery (PA). Percutaneous retrieval of the device was then decided upon. The right PA was accessed using a hydrophilic guidewire and a pigtail catheter. This catheter was exchanged for an 8-Fr sheathless guide catheter, and a 6-Fr Judkins right catheter was advanced into the right PA through the sheathless guide catheter using the mother-and-child technique. Multiple attempts using a snare were made to retrieve the migrated device. Eventually, the proximal marker point, the hub of the device, was grasped and pulled back from the PA, then externalized through the sheath without the need for surgical cutdown. Our report represents a case of complete percutaneous retrieval of an embolized VSD occluder device from the PA.


Assuntos
Comunicação Interventricular , Dispositivo para Oclusão Septal , Feminino , Humanos , Adulto Jovem , Adulto , Dispositivo para Oclusão Septal/efeitos adversos , Artéria Pulmonar/diagnóstico por imagem , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/cirurgia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Catéteres , Resultado do Tratamento
4.
J Cardiovasc Electrophysiol ; 35(5): 1046-1049, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38468182

RESUMO

INTRODUCTION: Left atrial appendage (LAA) closure (LAAC) is considered a viable alternative to anticoagulation therapy for stroke prevention in nonvalvular atrial fibrillation, we report a case with a less common shunt resulting from a device-related coronary artery-appendage fistula (CAAF) following LAAC. METHODS AND RESULTS: A 67-year-old male with a history of LAAC was referred to our emergency room with recurrent chest pain and palpitations and was diagnosed with ischemic angina pectoris. Subsequent coronary angiography (CAG) revealed 70% in-stent restenosis and an abnormal shunt of contrast originating from the left circumflex artery (LCA) to the LAA tip which did not exist before. The restenosis was successfully dilated using a drug-coated balloon, the procedure was safely completed without pericardial effusion. The patient had been implanted with a LAmbre occluder (Lifetech Scientific Corp.) in the previous LAAC procedure. This occluder had a lobe-disk design, and the distal umbrella was not fully opened after release, particularly in the lower portion. This could make the hooks embedded on the umbrella contact the LAA wall more tightly, possibly resulting in microperforation and coincidental impingement of the LCA. The epicardial adipose and hyperplastic tissue then chronically wrapped the perforated site, prevented blood outflow into the epicardium, and ultimately formed a CAAF. CONCLUSION: CAAF is a rare complication after LAAC but may be underestimated, especially for lobe-disk designed occluders. Therefore, CAG is perhaps necessary to detect this complication.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Idoso , Humanos , Masculino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Vasos Coronários/diagnóstico por imagem , Oclusão do Apêndice Atrial Esquerdo , Desenho de Prótese , Dispositivo para Oclusão Septal/efeitos adversos , Resultado do Tratamento , Fístula Vascular/diagnóstico por imagem , Fístula Vascular/etiologia
5.
J Invasive Cardiol ; 36(4)2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38412438

RESUMO

OBJECTIVES: Percutaneous closure of a patent foramen ovale (PFO) for the prevention of recurrent paradoxical thromboembolic events has been shown to be safe and effective in randomized controlled trials. However, it remains uncertain if differences in the structure and design of the occluder devices impact the outcomes. The aim of this study was to compare results of percutaneous PFO closure using 2 widely used double-disc occluders. METHODS: Consecutive patients who underwent percutaneous PFO closure with the Abbott Amplatzer occluder (APO) or the Occlutech Figulla-Flex-II occluder (OPO) at the Heart Center Lucerne between February 2017 and December 2022 were included in a registry. The primary endpoint was effective closure of the PFO, defined as a residual shunt grade 0 or 1, assessed by contrast echocardiogram at 6-month follow-up. Secondary endpoints included procedural efficacy/safety and major adverse cardiovascular events during the hospital stay and at 6-month follow-up. RESULTS: One hundred ninety-three consecutive patients (mean age 51.7 ± 12.5 years; 39% women; Risk of Paradoxical Embolism (RoPE) score = 7, IQR = 6-8) underwent percutaneous PFO closure with the APO (120 patients, 62.2%) or the OPO (73 patients, 37.8%). Main indications for closure were crypotogenic stroke in 168 patients (87.1%) and peripheral embolism in 13 patients (6.7%). At baseline, right-to-left shunt (RLS) greater than or equal to grade 2 was present in 189 patients (97.9%). Immediate procedural success was 99.5%. In 1 patient, an air embolism occurred during positioning of the APO occluder with transient chest pain and electrocardiogram changes, but without further sequelae to the patient. At 6-month follow-up, effective closure was achieved in 185 patients (95.8%; APO: 96.6% vs OPO: 94.5%, P = .30). Rates of atrial fibrillation and recurrent thromboembolic events were 4.2 and 0.5%, respectively. CONCLUSIONS: PFO closure is safe and effective when performed with either the self-expanding Abbott Amplatzer or Occlutech Figulla Flex II PFO occluder.


Assuntos
Forame Oval Patente , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Tromboembolia , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Masculino , Forame Oval Patente/diagnóstico , Forame Oval Patente/cirurgia , Forame Oval Patente/complicações , Resultado do Tratamento , Ecocardiografia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Dispositivo para Oclusão Septal/efeitos adversos , Tromboembolia/etiologia , Cateterismo Cardíaco/métodos
6.
Circ J ; 88(5): 663-671, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38325819

RESUMO

BACKGROUND: Complications arising from transcatheter closure of perimembranous ventricular septal defects (pmVSD) in children, such as residual shunts and aortic regurgitation (AR), have been observed. However, the associated risk factors remain unclear. This study identified risk factors linked with residual shunts and AR following transcatheter closure of pmVSD in children aged 2-12 years.Methods and Results: The medical records of 63 children with pmVSD and a pulmonary-to-systemic blood flow ratio <2.0 who underwent transcatheter closure between 2011 and 2018 were analyzed with a minimum 3-year follow-up. The success rate of transcatheter closure was 98.4%, with no emergency surgery, permanent high-degree atrioventricular block, or mortality. Defects ≥4.5 mm had significantly higher odds of persistent residual shunt (odds ratio [OR] 6.85; P=0.03). The use of an oversize device (≥1.5 mm) showed a trend towards reducing residual shunts (OR 0.23; P=0.06). Age <4 years (OR 27.38; 95% confidence interval [CI] 2.33-321.68) and perimembranous outlet-type VSD (OR 11.94, 95% CI 1.10-129.81) were independent risk factors for AR progression after closure. CONCLUSIONS: Careful attention is crucial for pmVSDs ≥4.5 mm to prevent persistent residual shunts in transcatheter closure. Assessing AR risk, particularly in children aged <4 years, is essential while considering the benefits of pmVSD closure.


Assuntos
Cateterismo Cardíaco , Comunicação Interventricular , Humanos , Comunicação Interventricular/cirurgia , Pré-Escolar , Criança , Fatores de Risco , Masculino , Feminino , Cateterismo Cardíaco/efeitos adversos , Estudos Retrospectivos , Dispositivo para Oclusão Septal/efeitos adversos , Resultado do Tratamento , Insuficiência da Valva Aórtica/etiologia , Fatores Etários , Fatores de Tempo , Seguimentos , Complicações Pós-Operatórias/etiologia
7.
J Formos Med Assoc ; 123(5): 600-605, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38238125

RESUMO

BACKGROUND: The diameter and shape of the left atrial appendage (LAA) orifices may influence occluder selection and the outcomes of left atrial appendage closure (LAAC) procedure. This study aimed to evaluate the impact of LAA orifice diameter on the safety and efficacy of LAAC using the LAmbre device. METHODS: A total of 133 patients with nonvalvular atrial fibrillation (AF) who underwent LAAC with the LAmbre device between June 2018 and June 2020 were included in this study. The patients were categorized into two groups based on the maximal diameter of the LAA orifice: the large LAA group (n = 45) with a maximal orifice diameter of ≥31 mm, and the normal LAA group (n = 88) with a maximal orifice diameter of <31 mm. The study assessed periprocedural characteristics and long-term clinical follow-up. RESULTS: Successful implantation of the LAmbre device was observed in all patients. The incidence of periprocedural peridevice leakage (PDL) was significantly higher in the large LAA group (P < 0.001), while the incidence of acute pericardial effusion (PE) during the procedure was comparable between the two groups (P = 1.000). After a mean follow-up period of 4.8 ± 1.7 years, three patients in the large LAA group developed delayed PE, while no patients in the normal LAA group did (P = 0.037). Additionally, a larger LAA maximal orifice diameter was associated with a higher prevalence of PDL (P = 0.001) and PE (including both acute and delayed PE) (P = 0.027). The optimal cutoff value of the LAA maximal orifice diameter for predicting PDL and PE after LAAC with the LAmbre device was determined to be 30 mm. CONCLUSION: The findings suggest that the LAmbre device is a safe and feasible option for occluding the LAA, regardless of its orifice diameter. However, it is important to note that a larger LAA orifice diameter may increase the risk of PDL and delayed PE.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Humanos , Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Dispositivo para Oclusão Septal/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Idoso de 80 Anos ou mais , Ecocardiografia Transesofagiana , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Oclusão do Apêndice Atrial Esquerdo
9.
Ann Cardiol Angeiol (Paris) ; 73(2): 101718, 2024 Apr.
Artigo em Francês | MEDLINE | ID: mdl-38262253

RESUMO

INTRODUCTION: Post-infarction ventricular septal defect (PIVSD) is one of the most serious mechanical complications of acute myocardial infarction (AMI). Over the last decade, percutaneous closure is increasingly undertaken, with results similar to cardiac surgery. We present a case of ST-elevated anterior AMI, complicated by apical PIVSD successfully treated with transcatheter closure. CASE REPORT: An 83-year-old man was hospitalized for chest pain occurred 18 hours before, during the night time. He was an active smoker. Clinical examination revealed normal heart sounds and pulmonary bibasilar crackles. ST-segment elevation with deep T waves inversion in anterior leads were detected on the electrocardiogram. A mildly-reduced ejection fraction (40%) was found by transthoracic echocardiogram. The patient underwent emergency coronary angiography, which revealed a subocclusive stenosis of the mid left anterior descending artery with a TIMI 2 flow, treated by balloon angioplasty and drug-eluting stent. Four days after revascularization, the patient developed an acute deterioration with signs of decompensated heart failure and a new holosystolic murmur with large irradiation. Inotropic agents' administration was required to maintain a precarious hemodynamic condition. A bedside Echo revealed an apical VSD, measuring 15 × 10 mm, with left-to-right shunting, and pulmonary hypertension. The patient was scheduled for transcatheter PIVSD closure. The procedure was performed under fluoroscopic guide. Two vascular access sites were placed, femoral arterial and right internal jugular vein. Through the right internal jugular vein, a 24-mm Amplatzer atrial septal occluder on a 9 French Amplatzer TREVISIO™ intravascular delivery system was advanced via right ventricle into the PIVSD. Contrast fluoroscopy was used to assess apposition and the degree of shunt reduction before release. Echocardiographic evaluation performed 48 hours later confirmed a correct apposition of the device with insignificant residual shunt. At 6 months follow-up, he was asymptomatic, with unchanged prosthetic findings. CONCLUSION: Percutaneous closure has been emerged as a valid cost-effective alternative to surgery and should be advised. However, debate remains on the optimal preprocedural optimization, timing of repair and modality of treatment.


Assuntos
Infarto Miocárdico de Parede Anterior , Procedimentos Cirúrgicos Cardíacos , Stents Farmacológicos , Comunicação Interventricular , Infarto do Miocárdio , Infarto do Miocárdio com Supradesnível do Segmento ST , Dispositivo para Oclusão Septal , Masculino , Humanos , Idoso de 80 Anos ou mais , Resultado do Tratamento , Stents Farmacológicos/efeitos adversos , Cateterismo Cardíaco/métodos , Infarto do Miocárdio/complicações , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Dispositivo para Oclusão Septal/efeitos adversos , Infarto Miocárdico de Parede Anterior/complicações , Comunicação Interventricular/complicações , Comunicação Interventricular/diagnóstico , Comunicação Interventricular/cirurgia , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Infarto do Miocárdio com Supradesnível do Segmento ST/complicações
10.
Cardiol Young ; 34(2): 455-458, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38167420

RESUMO

We report on a 6-month-old infant (6 Kg/ 64 cm) with perimembranous ventricular septal defect (absent sub-aortic rim, 10 mm left ventricular entry, and 4 and 6 mm right ventricular exists) and successful retrograde closure using an 8x6 mm KONAR-MF™ VSD occluder (Lifetech, China). Immediate and 48 hours post-procedure ultrasounds showed an accurately positioned device and two jets of mild-to-moderate residual shunts. At the 2-week follow-up, the device did not change position and the shunt was stable and intra-prosthetic. The scheduled 3-month follow-up was skipped for familial reasons. The patient came back without alarming symptoms for the regular 6-month follow-up, and the device was found embolised to the left pulmonary artery. The device was retrieved surgically, and the defect was patch-closed with excellent outcomes. There was a pseudoaneurysm involving the tricuspid valve chordae and the device was endothelialized partially on one edge suggesting that embolization occurred somewhere between 3 months and 6 months post-operative. Defects with compromised anatomies should be closed surgically to avoid suboptimal results, especially in small infants.


Assuntos
Embolização Terapêutica , Comunicação Interventricular , Dispositivo para Oclusão Septal , Lactente , Humanos , Cateterismo Cardíaco/métodos , Ecocardiografia , Embolização Terapêutica/efeitos adversos , Valva Tricúspide , Comunicação Interventricular/diagnóstico , Dispositivo para Oclusão Septal/efeitos adversos , Resultado do Tratamento
11.
Heart Surg Forum ; 27(1): E006-E013, 2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38286647

RESUMO

Primary heart tumors are rare, with atrial myxomas being the most common type. Atrial myxomas can lead to embolisms, heart obstruction, and systemic symptoms. Herein, we report a case of 72-year-old woman who presented with a left atrial myxoma at the atrial septal defect occluder, a new acute cerebral infarction, and MINOCA (myocardial infarction with no obstructive coronary atherosclerosis). Left atrial myxoma is a common primary cardiac tumor; however, left atrial myxomas arising after percutaneous atrial septal defect occlusion are rare. Additionally, the patient presented with a new case of multiple systemic emboli. The patient underwent surgical resection of a left atrial myxoma, occluder, and left atrium, and atrial septal repair, and was discharged with good recovery for outpatient follow-up. The possibility of a cardiac tumor, especially an atrial myxoma, which can lead to a series of complications, should be considered at the closure site after percutaneous atrial septal closure. Therefore, active surgical treatment and long-term follow-up are warranted in such cases.


Assuntos
Embolia , Neoplasias Cardíacas , Comunicação Interatrial , Embolia Intracraniana , Mixoma , Dispositivo para Oclusão Septal , Feminino , Humanos , Idoso , Dispositivo para Oclusão Septal/efeitos adversos , Embolia Intracraniana/diagnóstico , Embolia Intracraniana/etiologia , Embolia Intracraniana/cirurgia , MINOCA , Comunicação Interatrial/complicações , Comunicação Interatrial/diagnóstico , Comunicação Interatrial/cirurgia , Embolia/diagnóstico , Embolia/etiologia , Embolia/cirurgia , Átrios do Coração/cirurgia , Neoplasias Cardíacas/complicações , Neoplasias Cardíacas/diagnóstico , Neoplasias Cardíacas/cirurgia , Mixoma/complicações , Mixoma/diagnóstico , Mixoma/cirurgia , Cateterismo Cardíaco/efeitos adversos
12.
Pediatr Cardiol ; 45(2): 272-281, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38194099

RESUMO

The experience with percutaneous closure of postoperative residual ventricular septal defects (VSDs) is expanding with improved device technology and techniques. To report our experience with percutaneous closure of residual VSDs after cardiac surgeries. Retrospective clinical data review of patients who had percutaneous closure of postoperative residual VSDs at our institution between 2010 and 2022. Patients' demographics, procedural, and follow-up data were looked at. Twelve patients (50% males) with a median age of 9.2 years (range 0.9-22) were identified. Baseline surgeries were 8 tetralogy of Fallot corrections, 2 pulmonary bandings for large muscular VSD (mVSD) including 1 coarctation repair, 1 atrioventricular septal defect repair, 1 sub-aortic membrane resection-induced iatrogenic VSD, 1 isolated VSD closure, and 1 additional mVSD. Median duration between baseline surgery and percutaneous VSD closure was 2.2 years (range 0.2-8.3). Residual VSD shunting was secondary to surgical patch leakage in 8/12 patients. The median angiographic defect diameter was 6.8 mm (range 4.8-14). The defect was balloon-calibrated in 3/12 patients. Defects were tackled retrogradely in 3/9 patients. Amplatzer Membranous VSD occluder (n = 1), Lifetech Multifunctional (n = 5), Membranous (n = 1) and muscular VSD occluders (n = 2) and Occlutech Membranous (n = 1) and Muscular (n = 2) VSD occluders were used. The procedure was successful in 10/12 patients. Two devices embolized to the pulmonary artery and were snare-retrieved. Both patients were referred for surgery. The median follow-up was 1.3 years (range 0.1-12). Six-month ultrasound showed one trivial residual shunt and one mild right ventricular outflow obstruction. One patient is receiving targeted therapy for pulmonary hypertension at 2 years of follow-up. Transcatheter closure of postoperative residual VSDs is a feasible yet challenging intervention. Procedural complications can be encountered.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Comunicação Interventricular , Dispositivo para Oclusão Septal , Masculino , Humanos , Lactente , Pré-Escolar , Criança , Adolescente , Adulto Jovem , Adulto , Feminino , Estudos Retrospectivos , Resultado do Tratamento , Cateterismo Cardíaco/métodos , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/cirurgia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Dispositivo para Oclusão Septal/efeitos adversos
13.
Clin Cardiol ; 47(1): e24169, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37804320

RESUMO

BACKGROUND: Catheter ablation (CA) combined with left atrial appendage closure (LAAC) has emerged as a promising method to relieve symptoms while reducing the incidence of stroke in selected high-risk patients with atrial fibrillation (AF). HYPOTHESIS: We aimed to investigate the clinical outcomes of combined CA and LAAC in elderly patients. METHODS: A total of 316 patients with symptomatic drug-refractory AF who underwent combined CA and LAAC between January 2016 and December 2020 were retrospectively included. Baseline characteristics, periprocedural complications, and clinical events during follow-up were recorded and compared between patients aged ≥ 75 years (n = 66) and <75 years (n = 250). RESULTS: Pulmonary vein isolation and satisfactory LAAC were achieved in all patients. No patients experienced death or stroke/transient ischemic stroke periprocedurally. After a median follow-up of 12.2 (6.7-24.4) months and 11.9 (5.5-23.6) months, the rate of sinus rhythm maintenance was comparable between the two groups (≥75 years: 78.8% vs. <75 years: 80.8%; log-rank test, p = 0.674). The median follow-up periods for clinical outcomes were 27.9 (9.3-44.8) months and 25.2 (10.8-45.7) months, respectively. In patients aged ≥ 75 years, one suffered ischemic stroke, and one experienced major bleeding event. In patients aged < 75 years, four had ischemic stroke, and eight had major bleeding events. Two patients aged < 75 years died during follow-up, while none of the patients aged ≥ 75 years died. CONCLUSIONS: Combining CA and LAAC was feasible, safe and effective in elderly patients with AF.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , AVC Isquêmico , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Idoso , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Oclusão do Apêndice Atrial Esquerdo , Resultado do Tratamento , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Dispositivo para Oclusão Septal/efeitos adversos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Hemorragia/etiologia , AVC Isquêmico/etiologia , AVC Isquêmico/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
14.
Hellenic J Cardiol ; 75: 21-25, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37127207

RESUMO

BACKGROUND: The Cocoon patent foramen ovale (PFO) occluder is a new device especially designed for transcatheter closure of PFO. This occluder has some distinctive structural modifications aimed at reducing the risk of major complications of transcatheter PFO closure. In this report we present our initial experience to evaluate the efficacy and safety of the Cocoon PFO occluder in 253 patients who underwent transcatheter PFO closure. METHODS: The study cohort included 253 patients (median age 45 years) with embolic stroke of undetermined source who underwent attempted transcatheter closure of PFO for secondary prevention of paradoxical embolism. Patients were enrolled retrospectively from five sites in Greece and one in Romania between December 2016 and January 2021, and the median follow-up period was 28 months (range 12-48 months). Clinical and laboratory data from each participating center were sent to an electronic registry for evaluation and statistical analysis. RESULTS: The Cocoon PFO occluder was permanently implanted in all patients. At 6 months, complete occlusion of PFO was observed in 251/253 (99.2%) patients. Three (1.2%) patients had a trivial residual shunt. Thrombus formation on the device, which was successfully treated with recombinant tissue plasminogen activator infusion, was observed in one (0.4%) patient. No other complications occurred. During a median follow-up period of 28 months, 3 (1.2%) patients, aged 64-67 years, developed new onset paroxysmal atrial fibrillation. No neurologic events, cardiac erosions, allergic reactions to nickel, or thrombus formation occurred. CONCLUSION: The Cocoon PFO occluder is an effective and safe device that adds to our armamentarium for transcatheter closure of PFO.


Assuntos
Forame Oval Patente , Dispositivo para Oclusão Septal , Trombose , Humanos , Pessoa de Meia-Idade , Forame Oval Patente/complicações , Forame Oval Patente/cirurgia , Estudos Retrospectivos , Ativador de Plasminogênio Tecidual , Próteses e Implantes , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos , Dispositivo para Oclusão Septal/efeitos adversos
15.
World J Pediatr Congenit Heart Surg ; 15(1): 120-122, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37722806

RESUMO

Percutaneous ductal device closure in neonates is gaining popularity. Cardiac perforation is a rare but catastrophic complication that can occur during this procedure. Surgical options to salvage this situation are limited in extremely low-weight babies. In this report, we describe one such case managed successfully and offer some suggestions to achieve a successful outcome.


Assuntos
Apêndice Atrial , Traumatismos Cardíacos , Comunicação Interatrial , Dispositivo para Oclusão Septal , Recém-Nascido , Humanos , Esternotomia/efeitos adversos , Dispositivo para Oclusão Septal/efeitos adversos , Átrios do Coração/cirurgia , Apêndice Atrial/cirurgia , Comunicação Interatrial/cirurgia , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco/métodos
17.
J Am Heart Assoc ; 13(1): e030080, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38156658

RESUMO

BACKGROUND: Implantation of the left atrial appendage occluder (LAAO) has been proven to prevent stroke effectively in patients with atrial fibrillation who cannot tolerate anticoagulants. Incomplete endothelization of LAAO may cause device-related thrombus, and currently no good image modality exists to clearly see LAAO endothelialization. We aimed to use coronary optic coherence tomography (OCT) to visualize LAAO endothelialization. METHODS AND RESULTS: We enrolled 14 patients (72.8±9.4 years old) undergoing pulmonary vein isolation with a preexisting LAAO implanted more than 1 year ago (5 Watchman and 9 Amulet). After pulmonary vein isolation, we did OCT via steerable sheath and coronary guiding catheter to adjust OCT probe location and injected contrast medium to visualize the LAAO surface. In vitro testing was also performed to see the bare occluder. In vitro OCT showed the surface of the bare device as an interrupted granule pattern, which included the Watchman surface polytetrafluoroethylene membrane string, Amulet disc metal strut, and inner polytetrafluoroethylene membrane string. In the implanted Watchman, OCT showed endothelialization as a smooth surface layer with noninterrupted coarser granules. In the implanted Amulet, OCT showed endothelialization as thin (early) or thick (late) endothelialization layer covering struts with OCT shadows. Among patients with Watchman, 2 showed no, 2 early, and 1 complete endothelialization. Among patients with Amulet, 2 showed no, 3 early, and 4 late endothelialization. CONCLUSIONS: We demonstrated the feasibility of OCT to visualize LAAO endothelization with high resolution. Further studies are needed to determine antithrombotic regimens if incomplete endothelization is detected. A new OCT catheter may be designed specifically for LAAO.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Projetos Piloto , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Acidente Vascular Cerebral/etiologia , Cateterismo Cardíaco/efeitos adversos , Tomografia/efeitos adversos , Politetrafluoretileno , Resultado do Tratamento , Dispositivo para Oclusão Septal/efeitos adversos
18.
Rev. cuba. med ; 62(4)dic. 2023.
Artigo em Espanhol | LILACS, CUMED | ID: biblio-1550895

RESUMO

Introducción: Las complicaciones asociadas al procedimiento de colocación de un dispositivo de oclusión septal se presentan en menos del 10 por ciento de los casos. La embolización requiere de cirugía cardíaca, por lo que se incrementa el riesgo de la mortalidad. Objetivo: Presentar el caso en una paciente con comunicación interventricular e hipertensión pulmonar severa que se le retiró el dispositivo de oclusión septal transcateterismo. Presentación de caso: Se presentó una mujer de 24 años de edad con comunicación interventricular, insuficiencia cardíaca (New York Heart Association) clase IV e hipertensión pulmonar tipo 2, que se programó para la colocación de dispositivo de oclusión septal, sin embargo, presentó fallo en la colocación del dispositivo y defecto residual de 7 mm, por lo que se realizó el retiro de este 48 h después sin presentar complicaciones. Conclusiones: Aunque el cierre transcateterismo de la comunicación interventricular es una alternativa segura y efectiva a la cirugía, no está exento de complicaciones. En caso de translocación del dispositivo de oclusión septal este debe ser retirado durante el mismo procedimiento, ya que el riesgo de embolización es elevado y en caso de presentarse, el riesgo de muerte se incrementa(AU)


Introduction: Complications associated with the placement procedure of a septal occlusion device occur in less than 10percent of cases. Embolization requires cardiac surgery, which increases the risk of mortality. Objective: To report the case of a patient with ventricular septal defect and severe pulmonary hypertension who had the transcatheter septal occlusion device removed. Case report: We report the case report of a 24-year-old woman with ventricular septal defect, heart failure (New York Heart Association) class IV and type 2 pulmonary hypertension. She was scheduled for placement of a septal occlusion device, however, the placement of the device failed and had a residual defect of 7 mm, so the placement was removed 48 hours later without complications. Conclusions: Although transcatheter closure of the ventricular septal defect is a safe and effective alternative to surgery, it is not free of complications. In case of translocation of the septal occlusion device, it must be removed during the same procedure, since the risk of embolization is high and if it occurs, the risk of death increases(AU)


Assuntos
Humanos , Masculino , Feminino , Dispositivo para Oclusão Septal/efeitos adversos , Comunicação Interventricular/cirurgia
20.
J Am Heart Assoc ; 12(19): e030359, 2023 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-37776218

RESUMO

Background Scarce data exist on sex differences in patients with cryptogenic cerebrovascular events undergoing patent foramen ovale (PFO) closure. This study aimed to determine the sex differences in clinical profile, procedural characteristics, and long-term outcomes of patients with cryptogenic cerebrovascular events undergoing PFO closure. Methods and Results A retrospective cohort was used, including 1076 consecutive patients undergoing PFO closure because of a cryptogenic cerebrovascular event. Patients were divided into 2 groups: 469 (43.6%) women and 607 (56.4%) men. The median follow-up was 3 years (interquartile range, 2-8 years). Women were younger (46±13 versus 50±12 years; P<0.01) and had a higher risk of paradoxical embolism score (6.9±1.7 versus 6.6±1.6; P<0.01). Procedural characteristics and postprocedural antithrombotic therapy were similar. At follow-up, there were no differences in atrial fibrillation (women versus men: 0.47 versus 0.97 per 100 patient-years; incidence rate ratio [IRR], 0.55 [95% CI, 0.27-1.11]; P=0.095; adjusted P=0.901), stroke (0.17 versus 0.07 per 100 patient-years; IRR, 2.58 [95% CI, 0.47-14.1]; P=0.274; adjusted P=0.201), or transient ischemic attack (0.43 versus 0.18 per 100 patient-years; IRR, 2.58 [95% CI, 0.88-7.54]; P=0.084; adjusted P=0.121); nevertheless, women exhibited a higher incidence of combined ischemic cerebrovascular events (0.61 versus 0.26 per 100 patient-years; IRR, 2.58 [95% CI, 1.04-6.39]; P=0.041; adjusted P=0.028) and bleeding events (1.04 versus 0.45 per 100 patient-years; IRR, 2.82 [95% CI, 1.41-5.65]; P=0.003; adjusted P=0.004). Conclusions Compared with men, women with cryptogenic cerebrovascular events undergoing PFO closure were younger and had a higher risk of paradoxical embolism score. After a median follow-up of 3 years, there were no differences in stroke events, but women exhibited a higher rate of combined (stroke and transient ischemic attack) cerebrovascular events and bleeding complications. Additional studies are warranted to clarify sex-related outcomes after PFO closure further.


Assuntos
Embolia Paradoxal , Forame Oval Patente , Ataque Isquêmico Transitório , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Humanos , Feminino , Masculino , Ataque Isquêmico Transitório/epidemiologia , Ataque Isquêmico Transitório/etiologia , Forame Oval Patente/complicações , Forame Oval Patente/epidemiologia , Forame Oval Patente/cirurgia , Caracteres Sexuais , Embolia Paradoxal/epidemiologia , Embolia Paradoxal/etiologia , Estudos Retrospectivos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Cateterismo Cardíaco/efeitos adversos , Dispositivo para Oclusão Septal/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...