Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 146
Filtrar
1.
Expert Rev Med Devices ; 21(5): 439-446, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38803101

RESUMO

OBJECTIVES: Differentiation of iris and ciliary body lesions as benign or malignant and cystic or solid is important. The aim of this study was to compare anterior segment swept-source optical coherence tomography (AS SS-OCT) and ultrasound biomicroscopy (UBM) findings in iris and ciliary body tumors. RESEARCH DESIGN AND METHODS: Forty-two eyes of 38 cases with iris and ciliary body tumors imaged with UBM and AS SS-OCT between September 2018 and September 2023 were evaluated retrospectively. RESULTS: Of 42 eyes, 14 had melanoma, 14 iris pigment epithelial (IPE) cysts, 7 nevi, 3 Lisch nodules, 2 iris stromal cysts, 1 pars plana cysts, and 1 iris mammillations. An equivalent (100%) visualization of the anterior tumor margin was obtained with both techniques. Compared to AS SS-OCT, UBM was superior for posterior margin visualization in melanocytic tumors and IPE cysts. Bland-Altman plots demonstrated good agreement between UBM and AS SS-OCT for melanocytic tumors < 2.5 mm in base diameter and < 2 mm in thickness. CONCLUSIONS: Although, UBM is the gold standard for ciliary body and iridociliary tumors. AS SS-OCT should be considered as an excellent alternative to UBM, especially in minimally elevated iris lesions.


Assuntos
Corpo Ciliar , Microscopia Acústica , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Microscopia Acústica/métodos , Corpo Ciliar/diagnóstico por imagem , Corpo Ciliar/patologia , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Estudos Retrospectivos , Idoso , Neoplasias Uveais/diagnóstico por imagem , Neoplasias Uveais/patologia , Segmento Anterior do Olho/diagnóstico por imagem , Segmento Anterior do Olho/patologia , Neoplasias da Íris/diagnóstico por imagem , Adulto Jovem , Doenças da Íris/diagnóstico por imagem , Iris/diagnóstico por imagem , Iris/patologia , Adolescente
8.
J Glaucoma ; 30(5): 436-443, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33449588

RESUMO

PRECIS: Lens extraction with endocycloplasty (LE/ECPL) results in greater angle deepening than LE alone in plateau iris eyes. This study directly compares an LE/ECPL treatment group with a control group. PURPOSE: Quantitatively determine the effect of LE/ECPL versus LE alone for eyes with plateau iris configuration/plateau iris syndrome (PIC/PIS) on angle parameters. METHODS: Patients with PIC/PIS who underwent LE/ECPL or LE alone were reviewed. Eyes with ultrasound biomicroscopy-documented PIC that underwent anterior segment optical coherence tomography examination before and after treatment were included. Angle parameters, angle opening distance (AOD), trabecular-iris space area (TISA), and trabecular-iris circumference volume (TICV) were calculated. Angle parameters were compared between treatments using a 2-sample t test. P-values were adjusted by the false discovery rate method (P*). A paired t test was used to compare treated (nasal) and untreated (temporal) angles in LE/ECPL-treated eyes. RESULTS: Twenty-three eyes of 14 participants were included. Ten eyes (43%) eyes of 7 participants were treated with LE/ECPL, and 13 eyes (57%) of 7 participants were treated with LE alone. Angles were deepened in both groups (P<0.001). Changes in AOD, TISA, and TICV showed that the magnitude of deepening in treated (nasal) quadrants was greater in LE/ECPL eyes than in LE alone eyes (P<0.05). ECPL-treated angles deepened more than the untreated angles by AOD, TISA, and TICV (P<0.002). CONCLUSION: Our study suggests that LE/ECPL is more effective than LE alone in opening the anterior chamber angle and that ECPL deepens treated angles more than untreated angles. This study directly compares an LE/ECPL treatment group with a control group, LE alone, allowing for separation of the effect of ECPL from LE.


Assuntos
Glaucoma de Ângulo Fechado , Doenças da Íris , Câmara Anterior , Gonioscopia , Humanos , Pressão Intraocular , Iris/diagnóstico por imagem , Iris/cirurgia , Doenças da Íris/diagnóstico por imagem , Doenças da Íris/cirurgia , Projetos Piloto , Tomografia de Coerência Óptica
11.
J Glaucoma ; 29(11): 1036-1042, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32976290

RESUMO

PRéCIS:: The potential parameters for differentiating pupillary block (PB) from plateau iris configuration (PIC) on anterior segment optical coherence tomography (ASOCT) are lens/pupil size parameters and angles. Further study is needed to determine a landmark peripheral to the centroid of the iris. PURPOSE: Investigate anterior segment parameters to distinguish between 2 mechanisms of angle closure, PB and PIC, using swept-source Fourier domain ASOCT. PATIENTS AND METHODS: Retrospective ASOCT images from narrow angle eyes were reviewed. PIC was defined either by ultrasound biomicroscopy and/or clinically when an iridoplasty was performed. Images were read by a masked reader using Anterior Chamber Analysis and Interpretation software to identify scleral spur landmarks and calculate anterior chamber, peripheral angle, iris size, iris shape, and lens/pupil size parameters. ASOCT parameters were summarized and compared using the 2-sample t test. Thresholds and area under receiver operating characteristic curve were calculated using logistic regression analysis. RESULTS: One hundred eyes (66 PB and 34 PIC) of 100 participants were reviewed. Of all ASOCT parameters, iris length in each quadrant, pupil arc, lens/pupil parameters (pupil arc, lens vault, and pupil diameter), all pupillary margin-center point-scleral spur landmark (PM-C-SSL) parameters, and all except superior central iris vault parameters were significantly different between PB and PIC. On threshold evaluation, lens/pupil parameters had the greatest area under receiver operating characteristic curve values (0.77 to 0.80), followed by PM-C-SSL angles (0.71 to 0.75). CONCLUSIONS: We propose that the pupil size parameters and PM-C-SSL angle are the most reliable novel ASOCT parameters to distinguish between PB and PIC eyes. These parameters do not rely on the visibility of the posterior iris surface, which is difficult to identify with ASOCT, but may be ambient lighting dependent.


Assuntos
Segmento Anterior do Olho/diagnóstico por imagem , Glaucoma de Ângulo Fechado/diagnóstico por imagem , Doenças da Íris/diagnóstico por imagem , Distúrbios Pupilares/diagnóstico por imagem , Tomografia de Coerência Óptica , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Glaucoma de Ângulo Fechado/cirurgia , Gonioscopia , Humanos , Pressão Intraocular , Iridectomia , Masculino , Microscopia Acústica , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos
14.
J Glaucoma ; 29(9): e103-e105, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32694284

RESUMO

PURPOSE: To report a case of annular iris cyst presenting as a secondary angle closure managed with Nd:YAG laser iridotomy. DESIGN: Case report. METHODS: Institutional review board exemption for this case report was obtained from the institutional ethics committee, Aravind eye hospital, Tirunelveli. All research adhered to the tenets of the Declaration of Helsinki. Informed consent was obtained.A 45-year-old woman presented with a 2-week history of sudden onset of pain and redness in the right eye. Slit-lamp biomicroscopy showed corneal edema, with the shallow anterior chamber, convex bowing of iris, irregular shape of the pupil, and glaucomflecken on the clear lens. Ultrasound biomicroscopy revealed an annular iris cyst of the iris pigment epithelium. Nd:YAG laser iridotomy was done to drain the cyst and relieve the angle closure. RESULTS: Laser treatment resulted in the collapse of the cyst, confirmed by ultrasound biomicroscopy and disappearance of the subject symptoms. CONCLUSION: Iris cysts are usually benign in nature. An annular iris cyst is a rare presentation. They can present with a secondary angle closure as in our report. Correct diagnosis and timely intervention bring about a desirable result. With this report, the authors aim to catalog and familiarize ophthalmologists with a rare ocular pathology and its management.


Assuntos
Cistos/diagnóstico por imagem , Doenças da Íris/diagnóstico por imagem , Microscopia Acústica , Cistos/cirurgia , Feminino , Glaucoma de Ângulo Fechado/diagnóstico , Glaucoma de Ângulo Fechado/cirurgia , Gonioscopia , Humanos , Pressão Intraocular , Doenças da Íris/cirurgia , Terapia a Laser , Lasers de Estado Sólido/uso terapêutico , Pessoa de Meia-Idade
15.
Optom Vis Sci ; 97(6): 395-399, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32511160

RESUMO

SIGNIFICANCE: Cyclodialysis clefts can potentially develop secondary to open globe injury. The swept-source anterior segment optical coherence tomography (SS-AS-OCT) may be a valuable diagnostic tool for the identification and estimation of the circumferential extent of cyclodialysis clefts. It could be considered an alternative when ultrasound biomicroscopy cannot be performed successfully. PURPOSE: The purpose of this study was to report a case of open-globe injury associated with cyclodialysis cleft and the utility of SS-AS-OCT in its diagnosis. CASE REPORT: A 12-year-old boy presented to the clinic because of penetrating ocular trauma to his left eye with a projectile stone. He was diagnosed with limbal perforation with uveal tissue prolapse and cataract. He underwent limbal repair with cataract extraction and posterior chamber intraocular lens implantation. However, even at the 6 weeks' post-operative period, he did not gain vision and had persistent hypotony with hypotonic maculopathy. Gonioscopy showed a 2-clock-hour superonasal cyclodialysis cleft. However, on SS-AS-OCT, it was discovered that the cleft extended along 5 clock hours, involving both superonasal and inferonasal quadrants. Recognizing the large extent of the cleft, endocyclopexy by modified sewing-machine technique was planned and performed. An IOP spike and improvement in vision were noted on the next post-operative day. The SS-AS-OCT confirmed cleft closure. CONCLUSIONS: Although rare, cyclodialysis can occur in cases of open globe injury. The SS-AS-OCT is a useful diagnostic tool to study the circumferential extent of cyclodialysis and may unravel detachments hidden behind intact anterior ciliary body face.


Assuntos
Fendas de Ciclodiálise/diagnóstico por imagem , Fendas de Ciclodiálise/etiologia , Ferimentos Oculares Penetrantes/etiologia , Limbo da Córnea/lesões , Tomografia de Coerência Óptica , Catarata/etiologia , Extração de Catarata , Criança , Fendas de Ciclodiálise/cirurgia , Ferimentos Oculares Penetrantes/diagnóstico por imagem , Ferimentos Oculares Penetrantes/cirurgia , Gonioscopia , Humanos , Pressão Intraocular , Doenças da Íris/diagnóstico por imagem , Doenças da Íris/etiologia , Doenças da Íris/cirurgia , Implante de Lente Intraocular , Masculino , Microscopia Acústica , Prolapso
16.
Cornea ; 39(10): 1247-1251, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32398425

RESUMO

PURPOSE: Iris mammillations (IM) were previously described in patients with keratoconus, but the clinical implications of this finding have never been studied. Our aim was to investigate demographic, tomographic, and clinical characteristics potentially associated with the presence of IM among patients with keratoconus. METHODS: This was a cross-sectional study performed among patients with keratoconus in a public-affiliated university hospital. All patients under follow-up were considered eligible to participate in the study. Participants were evaluated by 2 trained ophthalmologists and submitted to corneal tomography (Pentacam). Selected demographic, clinical, and tomographic characteristics were assessed and compared among participants with IM (IM group) and without IM (No-IM group) using the Wilcoxon test or 2-tailed Fisher exact test, as appropriate. RESULTS: The study population consisted of 106 subjects and 19 (17.9%) presented with IM. The median age and interquartile range were 18 years old (14-24) in the IM group and 20 years old (17-24) in the No-IM group (P = 0.135). The female proportion was 47.3% in the IM group and 52.8% in the No-IM group (P = 0.801). Median (interquartile ranges) pachymetric values of the right eyes were 498 (466-525) for the IM group and 459 (421-482) for the No-IM group (P = 0.005). For the left eyes, the values were 490 (456-523) in the IM group and 450 (418-485) in the No-IM group (P = 0.024). CONCLUSIONS: Subjects with keratoconus presenting with IM have thicker corneas than those without IM. Follow-up studies should be performed to evaluate the clinical implications of this finding.


Assuntos
Doenças da Íris/epidemiologia , Ceratocone/epidemiologia , Tomografia Computadorizada por Raios X , Adolescente , Brasil/epidemiologia , Córnea/patologia , Paquimetria Corneana , Topografia da Córnea , Estudos Transversais , Demografia , Feminino , Humanos , Doenças da Íris/diagnóstico por imagem , Ceratocone/diagnóstico por imagem , Masculino , Tamanho do Órgão , Curva ROC , Acuidade Visual/fisiologia , Adulto Jovem
20.
Sci Rep ; 9(1): 10262, 2019 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-31311970

RESUMO

We evaluated regression of iris neovascularization (INV) using en-face anterior-segment optical coherence tomography angiography (AS-OCTA) after anti-vascular endothelial growth factor (VEGF) therapy. Seven consecutive eyes with INV were examined before and after anti-VEGF therapy, and all AS-OCTA scans were obtained using a swept-source OCTA system with an anterior-segment lens adapter. Slit-lamp microscopy photography and anterior indocyanine green angiography also were performed. Quantitative analyses of the vascular density, vascular lacunarity, and fractal dimension on AS-OCTA images were performed. AS-OCTA visualized the INV as signals around the pupillary margin, which corresponded to the vasculature confirmed by slit-lamp microscopy. After anti-VEGF drug injection, regression of INV was observed by AS-OCTA in all eyes (100%). The vascular density decreased and vascular lacunarity increased significantly after anti-VEGF therapy. This pilot study demonstrated the ability of AS-OCTA not only to detect but also to evaluate INV. Further study is warranted to improve the algorithm for delineating the iris vasculature to decrease artifacts.


Assuntos
Doenças da Íris/diagnóstico por imagem , Iris/irrigação sanguínea , Neovascularização Patológica/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Idoso , Inibidores da Angiogênese/uso terapêutico , Bevacizumab/uso terapêutico , Feminino , Angiofluoresceinografia/métodos , Humanos , Iris/diagnóstico por imagem , Doenças da Íris/tratamento farmacológico , Doenças da Íris/fisiopatologia , Masculino , Pessoa de Meia-Idade , Terapia de Alvo Molecular/métodos , Receptores de Fatores de Crescimento do Endotélio Vascular/uso terapêutico , Proteínas Recombinantes de Fusão/uso terapêutico , Resultado do Tratamento , Fator A de Crescimento do Endotélio Vascular/antagonistas & inibidores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...