Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 172
Filtrar
1.
Radiología (Madr., Ed. impr.) ; 64(4): 383-392, Jul - Ago 2022. ilus
Artigo em Espanhol | IBECS | ID: ibc-207306

RESUMO

La ablación por radiofrecuencia (ARF) es un método bien conocido, seguro y eficaz para tratar los nódulos tiroideos benignos, los cánceres tiroideos recurrentes, así como los adenomas de paratiroides, con resultados prometedores en los últimos años. Los dispositivos empleados y las técnicas básicas para la ARF fueron introducidos por la Sociedad Coreana de Radiología de Tiroides (KSThR) en 2012, si bien la ARF se ha aprobado en todo el mundo, con avances posteriores tanto en dispositivos como en técnica.El objetivo de esta revisión es instruir a los radiólogos intervencionistas que pretendan realizar, o que ya estén realizando, intervenciones de ARF, así como especialistas en tiroides y paratiroides que brinden atención pre y postoperatoria, acerca de la capacitación, la ejecución y el control de calidad de la ARF de los nódulos tiroideos y adenomas paratiroideos, para optimizar la eficacia del tratamiento y la seguridad del paciente.(AU)


Radiofrequency ablation is a well-known, safe, and effective method for treating benign thyroid nodules and recurring thyroid cancer as well as parathyroid adenomas that has yielded promising results in recent years. Since the Korean Society of Thyroid Radiology introduced the devices and the basic techniques for radiofrequency ablation in 2012, radiofrequency ablation has been approved all over the world and both the devices and techniques have improved.This review aims to instruct interventional radiologists who are doing or intend to start doing radiofrequency ablation of thyroid and parathyroid lesions, as well as thyroid and parathyroid specialists who provide pre- and post-operative care, in the training, execution, and quality control for radiofrequency ablation of thyroid nodules and parathyroid adenomas to optimize the efficacy and safety of the treatment.(AU)


Assuntos
Humanos , Masculino , Feminino , Ablação por Radiofrequência , Doenças da Glândula Tireoide/diagnóstico por imagem , Doenças da Glândula Tireoide/diagnóstico , Doenças das Paratireoides/diagnóstico por imagem , Doenças das Paratireoides/diagnóstico , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/terapia , Radiologistas/educação , Radio-Oncologistas/educação , Radiologia , Nódulo da Glândula Tireoide , Adenocarcinoma
2.
Neuroimaging Clin N Am ; 32(1): 145-157, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34809835

RESUMO

The thyroid and parathyroid glands are endocrine structures located in the visceral space of the infrahyoid neck. Imaging plays a critical role in the evaluation of patients with thyroid cancer, both in the pre and posttreatment setting. Disorders of thyroid function, that is, hyperthyroidism and hypothyroidism, are also fairly common, although imaging utilization is less frequent with these conditions. Parathyroid dysfunction results in disordered calcium metabolism. Imaging is frequently applied in the preoperative assessment of these patients undergoing parathyroidectomy; however, routine imaging in the postoperative setting is uncommon. Parathyroid carcinoma is rare; however, imaging may be used in the pre and posttreatment setting.


Assuntos
Doenças das Paratireoides , Neoplasias da Glândula Tireoide , Humanos , Doenças das Paratireoides/diagnóstico por imagem , Doenças das Paratireoides/cirurgia , Glândulas Paratireoides/diagnóstico por imagem , Glândulas Paratireoides/cirurgia , Neoplasias da Glândula Tireoide/cirurgia , Tireoidectomia
4.
J Surg Oncol ; 123(4): 866-871, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33333584

RESUMO

BACKGROUND: Intraoperative near-infrared imaging (NIFI) of parathyroid glands (PG) by first-generation technology had limited image quality and depth penetration. Second-generation NIFI has recently been introduced. Our aim was to compare (1) capability to detect PG and (2) image quality between older and newer technologies. METHODS: Accurately detecting PG, as well as, quality of autofluorescence (AF) was compared between an older charge-coupled device (CCD) camera and a newer complementary metal-oxide semiconductor (CMOS). χ2 , t test, and analysis of variance were used for analysis. RESULTS: There were 300 patients who underwent parathyroidectomy (PTX) and/or thyroidectomy (THY) with NIFI, 200 with CCD, and 100 with CMOS. Although both NIFI technologies detected >94% of PG, CMOS was superior to CCD. Comparing AF quality, mean pixel intensity of PG compared with the background was higher with CMOS compared with CCD. When comparing PG detected by NIFI before visual identification by a surgeon, both CCD and CMOS had similar results (25% vs. 22%; p = .3). CONCLUSION: Both NIFI cameras were excellent at detecting PG. Second-generation NIFI (CMOS) displayed higher detection rates and AF intensity. Although surgeons identified majority of PG before NIFI detection, 25% of PG were identified with NIFI first, suggesting future advancements of this technology may expand its applications during parathyroid/thyroid operations.


Assuntos
Imagem Óptica/métodos , Doenças das Paratireoides/patologia , Glândulas Paratireoides/patologia , Semicondutores , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Feminino , Humanos , Masculino , Metais/química , Pessoa de Meia-Idade , Doenças das Paratireoides/diagnóstico por imagem , Doenças das Paratireoides/cirurgia , Glândulas Paratireoides/diagnóstico por imagem , Glândulas Paratireoides/cirurgia , Paratireoidectomia , Prognóstico , Estudos Prospectivos
5.
Radiographics ; 40(5): 1383-1394, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32678698

RESUMO

Parathyroid four-dimensional (4D) CT is an increasingly used and powerful tool for preoperative localization of abnormal parathyroid tissue in the setting of primary hyperparathyroidism. Accurate and precise localization of a single adenoma facilitates minimally invasive parathyroidectomy, and localization of multiglandular disease aids bilateral neck exploration. However, many radiologists find the interpretation of these examinations to be an intimidating challenge. The authors review parathyroid 4D CT findings of typical and atypical parathyroid lesions and provide illustrative examples. Relevant anatomy, embryology, and operative considerations with which the radiologist should be familiar to provide clinically useful image interpretations are also discussed. The most important 4D CT information to the surgeon includes the number, size, and specific location of candidate parathyroid lesions with respect to relevant surgical landmarks; the radiologist's opinion and confidence level regarding what each candidate lesion represents; and the presence or absence of ectopic or supernumerary parathyroid tissue, concurrent thyroid pathologic conditions, and arterial anomalies associated with a nonrecurrent laryngeal nerve. The authors provide the radiologist with an accessible and practical approach to performing and interpreting parathyroid 4D CT images, detail what the surgeon really wants to know from the radiologist and why, and provide an accompanying structured report outlining the key information to be addressed. By accurately reporting and concisely addressing the key information the surgeon desires from a parathyroid 4D CT examination, the radiologist substantially impacts patient care by enabling the surgeon to develop and execute the best possible operative plan for each patient. ©RSNA, 2020.


Assuntos
Tomografia Computadorizada Quadridimensional/métodos , Doenças das Paratireoides/diagnóstico por imagem , Doenças das Paratireoides/cirurgia , Pontos de Referência Anatômicos , Meios de Contraste , Humanos , Paratireoidectomia
6.
Chem Commun (Camb) ; 56(16): 2431-2434, 2020 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-31995041

RESUMO

A composite nanosensor based on Zr(iv)-MOFs and PNPP was developed, and was successfully applied for the in situ fluorescence imaging of phosphate and ALP levels in mice with parathyroid dysfunction. The current work provides new ideas for further development of the diagnosis of parathyroid diseases.


Assuntos
Fosfatase Alcalina/análise , Corantes Fluorescentes/química , Estruturas Metalorgânicas/química , Nanopartículas/química , Doenças das Paratireoides/diagnóstico por imagem , Fosfatos/análise , Zircônio/química , Fosfatase Alcalina/metabolismo , Animais , Modelos Animais de Doenças , Corantes Fluorescentes/síntese química , Estruturas Metalorgânicas/síntese química , Camundongos , Doenças das Paratireoides/metabolismo
7.
Clin Radiol ; 75(3): 179-184, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31767140

RESUMO

AIM: To identify the differences between ultrasound (US) features of parathyroid carcinoma (PC) and benign parathyroid (BP) lesions in patients with primary hyperparathyroidism (PHPT). MATERIAL AND METHODS: Twenty-one patients with PC and 64 consecutive patients with BP, whose diagnoses were confirmed at surgery, were enrolled from January 2013 to December 2018. The US features, demographic, clinical, and biochemical characteristics of the two groups were compared retrospectively. RESULTS: There are no significant differences between the patients with PC and BP regarding mean age or mean ionized calcium levels but differences were seen in sex distribution and mean parathyroid hormone (PTH) levels. On US imaging, PC significantly exhibited higher incidences of larger size and higher depth/width (D/W) ratio, heterogeneous echotexture, irregular shape, non-circumscribed margin, intra-nodular calcifications, indistinct border, cystic change, and the presence of suspicious lymph nodes compared to BP lesions. CONCLUSION: Preoperative ultrasonography is helpful to differentiate PC and BP. Patients with PC are differentiated from BP by their sex distribution, mean PTH levels, and major US characteristics: larger size, higher D/W ratio, heterogeneous echotexture, irregular shape, non-circumscribed margin, indistinct border, intra-nodular calcifications, cystic change, and the presence of suspicious lymph nodes.


Assuntos
Carcinoma/diagnóstico por imagem , Neoplasias das Paratireoides/diagnóstico por imagem , Ultrassonografia/métodos , Adolescente , Adulto , Idoso , Carcinoma/cirurgia , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doenças das Paratireoides/diagnóstico por imagem , Doenças das Paratireoides/cirurgia , Neoplasias das Paratireoides/cirurgia , Cuidados Pré-Operatórios , Estudos Retrospectivos
8.
Vet Radiol Ultrasound ; 60(6): 729-733, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31353771

RESUMO

Accurate ultrasonographic differentiation of normal versus abnormal parathyroid glands is important for clinical workup and presurgical screening in dogs with hypercalcemia. In previous published studies, size has been the only ultrasonographic criterion correlated with histologic diagnoses of abnormal parathyroid glands. In this retrospective, cross-sectional study, the medical records of dogs with ultrasonographic examinations of the parathyroid glands and histologic diagnoses of parathyroid gland hyperplasia, adenoma, and adenocarcinoma were evaluated. Ultrasonographic characteristics were recorded for each gland and compared among histologic diagnosis groups. A total of 49 dogs and 59 parathyroid glands were sampled and assigned to the following groups for analyses: adenoma (n = 24), hyperplastic (n = 20), and adenocarcinoma (n = 15). There were no associations with dog age, sex, weight, breed; or gland laterality, location, ultrasonographic shape, or echogenicity among histologic diagnosis groups (P > .05). Parathyroid gland adenocarcinomas were found to be less likely to have a homogeneous echotexture on ultrasonographic evaluation, with hyperplastic glands being smaller (P = .022) and adenocarcinomas being larger (P = .042). While 3 mm was the optimum cutoff for differentiating hyperplastic and neoplastic parathyroid glands in this sample of dogs, values varied widely within groups and there were overlapping values between groups. Therefore, authors caution against using ultrasonographic size as a sole criterion for differentiating hyperplasia from neoplasia and normal versus abnormal parathyroid glands.


Assuntos
Doenças do Cão/diagnóstico por imagem , Hipercalcemia/veterinária , Doenças das Paratireoides/veterinária , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/veterinária , Adenoma/diagnóstico por imagem , Adenoma/veterinária , Animais , Estudos Transversais , Doenças do Cão/patologia , Cães , Feminino , Hipercalcemia/diagnóstico por imagem , Masculino , Doenças das Paratireoides/diagnóstico por imagem , Neoplasias das Paratireoides/diagnóstico por imagem , Neoplasias das Paratireoides/veterinária , Estudos Retrospectivos , Ultrassonografia/veterinária
9.
J Am Coll Surg ; 228(5): 730-743, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30769112

RESUMO

BACKGROUND: Misidentifying parathyroid glands (PGs) during thyroidectomies or parathyroidectomies could significantly increase postoperative morbidity. Imaging systems based on near infrared autofluorescence (NIRAF) detection can localize PGs with high accuracy. These devices, however, depict NIRAF images on remote display monitors, where images lack spatial context and comparability with actual surgical field of view. In this study, we designed an overlay tissue imaging system (OTIS) that detects tissue NIRAF and back-projects the collected signal as a visible image directly onto the surgical field of view instead of a display monitor, and tested its ability for enhancing parathyroid visualization. STUDY DESIGN: The OTIS was first calibrated with a fluorescent ink grid and initially tested with parathyroid, thyroid, and lymph node tissues ex vivo. For in vivo measurements, the surgeon's opinion on tissue of interest was first ascertained. After the surgeon looked away, the OTIS back-projected visible green light directly onto the tissue of interest, only if the device detected relatively high NIRAF as observed in PGs. System accuracy was determined by correlating NIRAF projection with surgeon's visual confirmation for in situ PGs or histopathology report for excised PGs. RESULTS: The OTIS yielded 100% accuracy when tested ex vivo with parathyroid, thyroid, and lymph node specimens. Subsequently, the device was evaluated in 30 patients who underwent thyroidectomy and/or parathyroidectomy. Ninety-seven percent of exposed tissue of interest was visualized correctly as PGs by the OTIS, without requiring display monitors or contrast agents. CONCLUSIONS: Although OTIS holds novel potential for enhancing label-free parathyroid visualization directly within the surgical field of view, additional device optimization is required for eventual clinical use.


Assuntos
Aumento da Imagem/métodos , Imagem Óptica/métodos , Glândulas Paratireoides/diagnóstico por imagem , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Adulto , Idoso , Desenho de Equipamento , Feminino , Fluorescência , Humanos , Aumento da Imagem/instrumentação , Masculino , Pessoa de Meia-Idade , Imagem Óptica/instrumentação , Doenças das Paratireoides/diagnóstico por imagem , Doenças das Paratireoides/cirurgia , Glândulas Paratireoides/cirurgia , Paratireoidectomia , Imagens de Fantasmas , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação , Cirurgia Assistida por Computador , Doenças da Glândula Tireoide/diagnóstico por imagem , Doenças da Glândula Tireoide/cirurgia , Tireoidectomia
10.
Radiol Med ; 124(5): 360-367, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30607865

RESUMO

PURPOSE: To evaluate the MRI findings of solid parathyroid lesions and to elaborate on a possible improvement of MRI detection of parathyroid lesions by the use of additional DWI. MATERIALS AND METHODS: MRI and DWI properties of pathologically proven 20 solid parathyroid lesions were retrospectively reviewed. Mean ADC values (b50 + b400 + b800/3) of parathyroid lesions were compared with that of normal appearing thyroid parenchyma (TP), sternocleidomastoid muscle (SCM) and jugulodigastric lymph nodes (JDLN). RESULTS: Of lesions, 4 were parathyroid hyperplasia, 13 parathyroid adenoma and 3 parathyroid adenocarcinoma. All parathyroid lesions were very bright on fat-saturated T2W images. Parathyroid hyperplasia and adenoma were small sized, homogenous, well-defined and low on T1W, high on T2W and avidly enhancing. Parathyroid carcinoma was large sized, ill-defined and very heterogeneous on MRI including DWI. Means ADC values of parathyroid hyperplasia, adenoma, and adenocarcinoma, TP, SCM and JDLN were measured as 2.3 ± 0.14 × 10-3, 1.7 ± 0.45 × 10-3, 1.5 ± 1.48 × 10-3, 0.87 ± 0.40 × 10-3, 0.55 ± 0.21 × 10-3 and 0.96 ± 0.33 × 10-3 mm2/s, respectively. All parathyroid lesions had high diffusion properties comparing other soft tissue structures of head and neck region. By increasing strength (b value) of diffusion tensor on DWI, solid parathyroid lesions still kept their brightness comparing other soft tissue structures of head and neck region because of their high T2 properties. CONCLUSION: Solid parathyroid lesions had higher diffusion properties comparing other soft tissues structures of head and neck region. This feature makes them easily differentiate from nearby structures on fat-saturated T2W and DWI.


Assuntos
Imageamento por Ressonância Magnética/métodos , Doenças das Paratireoides/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Doenças das Paratireoides/patologia , Estudos Retrospectivos
12.
Clin Nucl Med ; 43(12): 943-945, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30325824

RESUMO

A 56-year-old woman with secondary hyperparathyroidism was referred for preoperative localization of hyperfunctioning parathyroid lesions. Tc-MIBI dual-phase and SPECT/CT parathyroid scan showed multiple focal activities behind the thyroid and in the anterior mediastinum, diagnosed as parathyroid hyperplasia. However, the histopathological findings proved them to be hyperplastic parathyroid glands and remnant thymic tissue after parathyroidectomy and unnecessary thoracotomy, respectively.


Assuntos
Coristoma/diagnóstico por imagem , Hiperparatireoidismo Secundário/diagnóstico por imagem , Doenças do Mediastino/diagnóstico por imagem , Doenças das Paratireoides/diagnóstico por imagem , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Timo , Erros de Diagnóstico , Feminino , Humanos , Hiperplasia , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi
14.
Surgery ; 163(1): 35-41, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29154082

RESUMO

BACKGROUND: The role of preoperative localization studies in patients with hyperparathyroidism and expected multigland disease remains poorly defined. Our study investigates the usefulness of obtaining preoperative sestamibi scans and ultrasonography of the neck in identifying ectopic glands in this group of patients. METHODS: Under Institutional Review Board approval, we performed a retrospective review of patients who underwent operation for secondary hyperparathyroidism, tertiary hyperparathyroidism, lithium-induced hyperparathyroidism, and multiple endocrine neoplasia syndrome at a tertiary institution between 2004 and 2015. We reviewed patient demographics, laboratory, radiology, pathology, and operative reports. RESULTS: Of 2,975 parathyroidectomies performed during this period, 154 operations were performed in 149 patients who met the criteria. Of the 149 patients, 82 (55.0%) had secondary, 31 (20.8%) had tertiary, 23 (15.4%) had lithium-induced HPT, and 13 (10.1%) had multiple endocrine neoplasia syndrome; 86 ectopic glands were identified in 64 patients (43.0%). Sensitivity for identification of ectopic glands was 29% for sestamibi scan and 7% for ultrasonography, while 89% of mediastinal glands were localized by sestamibi scans and thoracotomy, thoracoscopy, or sternotomy occurred in 4.7% of patients. CONCLUSION: We found a greater rate of preoperative localization of ectopic glands than reported previously. Because the sensitivity of sestamibi for identification of ectopic glands is 23.0%, the implication of missing mediastinal glands warrants preoperative imaging.


Assuntos
Doenças das Paratireoides/diagnóstico por imagem , Glândulas Paratireoides , Tecnécio Tc 99m Sestamibi , Adulto , Idoso , Idoso de 80 Anos ou mais , Coristoma/diagnóstico por imagem , Coristoma/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doenças das Paratireoides/cirurgia , Cintilografia/estatística & dados numéricos , Estudos Retrospectivos , Ultrassonografia/estatística & dados numéricos , Adulto Jovem
15.
Med Ultrason ; 19(4): 386-391, 2017 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-29197915

RESUMO

AIMS: The aim of this study was to prospectively assess the feasibility of the Virtual Touch tissue imaging quantification (VTIQ) method of shear wave elastography (SWE) for the discrimination of parathyroid lesions and to compare the lesions' stiffness with that of cervical lymph nodes. MATERIALS AND METHODS: SWE using VTIQ was performed on 66 patients with 87 histopathologically proven parathyroid lesions (54 parathyroid adenomas and 33 parathyroid hyperplasia) and 29 patients with 31 inflammatory cervical lymph nodes. The mean SWVs of the lesions were compared and receiver operating characteristic (ROC) curve analysis was used to evaluate diagnostic performance. RESULTS: The mean SWV of parathyroid adenomas (2.16±0.33 m/s) differed significantly from those of parathyroid hyperplasia and lymph nodes (1.75±0.28 m/s and 1.86±0.37 m/s respectively, p<0.001). Selecting a cutoff value of 1.92 m/s for diagnosing adenoma led to 80% sensitivity and 82% specificity (area under the curve [AUC]: 0.832 [95% confidence interval (CI): 0.742-0.921], p< 0.001). CONCLUSIONS: The VTIQ method of SWE can contribute to the differentiation of parathyroid adenoma from parathyroid hyperplasia and cervical lymphnodes.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Linfonodos/diagnóstico por imagem , Doenças das Paratireoides/diagnóstico por imagem , Glândulas Paratireoides/diagnóstico por imagem , Diagnóstico Diferencial , Estudos de Viabilidade , Feminino , Humanos , Linfonodos/patologia , Masculino , Pessoa de Meia-Idade , Pescoço , Doenças das Paratireoides/patologia , Glândulas Paratireoides/patologia , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
World J Surg ; 41(6): 1506-1512, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28168320

RESUMO

BACKGROUND: Intraoperative identification of the difficult-to-spot parathyroid gland is critical during surgery for thyroid and parathyroid disease. Recently, intrinsic fluorescence of the parathyroid gland was identified, and a new method was developed for intraoperative detection of the parathyroid with an original fluorescent detection apparatus. Here, we describe a method for intraoperative detection of the parathyroid using a ready-made photodynamic eye (PDE) system without any fluorescent dye or contrast agents. METHODS: Seventeen patients who underwent surgical treatment for thyroid or parathyroid disease at Kagoshima University Hospital were enrolled in this study. Intrinsic fluorescence of various tissues was detected with the PDE system. Intraoperative in vivo and ex vivo intrinsic fluorescence of the parathyroid, thyroid, lymph nodes and fat tissues was measured and analyzed. RESULTS: The parathyroid gland had a significantly higher fluorescence intensity than the other tissues, including the thyroid glands, lymph nodes and fat tissues, and we could identify them during surgery using the fluorescence-guided method. Our method could be applicable for two intraoperative clinical procedures: ex vivo tissue identification of parathyroid tissue and in vivo identification of the location of the parathyroid gland, including ectopic glands. CONCLUSION: The PDE system may be an easy and highly feasible method to identify the parathyroid gland during surgery.


Assuntos
Doenças das Paratireoides/cirurgia , Glândulas Paratireoides/cirurgia , Doenças da Glândula Tireoide/cirurgia , Adulto , Idoso , Feminino , Fluorescência , Humanos , Masculino , Pessoa de Meia-Idade , Doenças das Paratireoides/diagnóstico por imagem , Glândulas Paratireoides/diagnóstico por imagem , Doenças da Glândula Tireoide/diagnóstico por imagem
18.
Gen Thorac Cardiovasc Surg ; 65(1): 52-55, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26353995

RESUMO

Mediastinal parathyroid cysts (PC) are rare, benign lesions, reported in fewer than 150 cases worldwide. Although most are asymptomatic and discovered incidentally on imaging, symptoms of dyspnea, dysphagia, hoarseness, palpitations, hypercalcemia, and innominate or jugular venous thrombosis have been reported. Sternotomy or thoracotomy has traditionally been the approach used to resect mediastinal PCs. We describe the first reported case of a robot-assisted resection of a mediastinal PC.


Assuntos
Cisto Mediastínico/cirurgia , Doenças das Paratireoides/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Diagnóstico Diferencial , Dispneia/etiologia , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Cisto Mediastínico/complicações , Cisto Mediastínico/diagnóstico por imagem , Pessoa de Meia-Idade , Doenças das Paratireoides/complicações , Doenças das Paratireoides/diagnóstico por imagem , Toracotomia/métodos
20.
Artigo em Chinês | MEDLINE | ID: mdl-27345882

RESUMO

OBJECTIVE: To study the pathological and clinical features and the surgical results of the mass in the pretracheal space. METHODS: From 1999 to 2004, 8 females and 3 males with an average of 43 years (from 32 to 61 years) were included CT scan, nuclear imaging, ultrasound and ultrasound-guided aspiration, endoscopic and laboratory measure were used in the evaluation for the masses before operation. Complete removal of mass was carried out in all patients under general anesthesia, and continuous negative pressure draining was routinely used. RESULTS: Six masses with firm consistency could be moved easily transversely, but slightly moveable with swallowing. On contrast CT or ultrasound, all the masses had clear circumscription and showed rounded or lobular shape. No hemorrhage, chylous or lymph leakage, or recurrent laryngeal injury was encountered. Goiter was found in 6 cases, parathyroid adenoma in 2 cases, and thymoma, parathyroid cyst or lymphatic cyst was diagnosed in the rest three patients respectively. No recurrence was found with the following-up of 7 - 42 months. CONCLUSIONS: Goiter, parathyroid adenoma and thymoma were common lesions presenting as mass in the pretracheal space and surgically curable without complications.


Assuntos
Cistos/diagnóstico por imagem , Bócio/diagnóstico por imagem , Doenças das Paratireoides/cirurgia , Neoplasias das Paratireoides/diagnóstico por imagem , Timoma/diagnóstico por imagem , Adulto , Cistos/cirurgia , Endoscopia , Feminino , Bócio/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Doenças das Paratireoides/diagnóstico por imagem , Neoplasias das Paratireoides/cirurgia , Timoma/cirurgia , Tomografia Computadorizada por Raios X , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...