Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
2.
Rev. bras. oftalmol ; 80(5): e0037, 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1341160

RESUMO

ABSTRACT The term dysfunctional lens syndrome has gained acceptance in the field and encompasses natural changes due to aging of crystalline lens. The evolution of diagnostic devices has been a key factor in better staging, understanding and characterizing of these degenerative changes. Even with these technological advances and the use of subjective classifications, such as the classic Lens Opacities Classification System, an objective staging of early dysfunctional lens syndrome has yet to be established. Ocular wavefront aberrometry and objective scatter index, associated with Scheimpflug backscatter densitometry, have proven instrumental in detecting early dysfunctional lens syndrome. Staging of early dysfunctional lens syndrome has been proposed in the literature, but no classification has been recognized worldwide. The purpose of this literature review is to assess the current state of dysfunctional lens syndrome from a technological perspective and propose a new staging system to assist surgeons in making surgical decisions.


RESUMO O termo "síndrome disfuncional do cristalino" tem sido mais aceito na área e engloba mudanças naturais devido ao envelhecimento do cristalino. A evolução dos dispositivos diagnósticos tem sido fator fundamental para melhor estadiamento, compreensão e caracterização dessas alterações. Mesmo com esses avanços tecnológicos e o uso de classificações subjetivas, como o Lens Opacities Classification System , um estadiamento objetivo da síndrome disfuncional do cristalino precoce ainda não foi estabelecido. A aberrometria ocular total e o índice de superfície ocular, associado à densitometria de Scheimpflug, mostraram-se instrumentais na detecção da síndrome disfuncional do cristalino precoce. Embora estadiamentos precoces de síndrome disfuncional do cristalino tenham sido propostos na literatura, nenhum foi reconhecido mundialmente até o momento. O objetivo desta revisão de literatura é avaliar o estado atual da síndrome disfuncional do cristalino a partir de uma perspectiva tecnológica, e propor um novo sistema de estadiamento para auxiliar os cirurgiões na tomada de decisões cirúrgicas.


Assuntos
Humanos , Acomodação Ocular/fisiologia , Cristalino , Doenças do Cristalino/diagnóstico por imagem , Presbiopia , Catarata , Diagnóstico por Imagem/métodos , Acuidade Visual , Técnicas de Diagnóstico Oftalmológico , Aberrações de Frente de Onda da Córnea
3.
BMJ Case Rep ; 12(9)2019 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-31537600

RESUMO

Intraocular lens (IOL) opacification is a rare phenomenon noted with hydrophilic acrylic IOLs. We report a case of advanced IOL opacification appreciated on anterior segment optical CT (ASOCT)as a shrunken biconcave optic retracted away from the posterior capsule (PC), unlike the other eye which had a clear biconvex IOL of similar material abutting the PC. After IOL exchange, the affected eye was noted to have more folds and Elschnig's pearls on the PC when compared with the other eye. Our case points towards rare IOL changes seen in advanced cases of opacification, their association with posterior capsular changes and the aid of ASOCT as a non-invasive tool in diagnosing them correctly.


Assuntos
Segmento Anterior do Olho/diagnóstico por imagem , Doenças do Cristalino/diagnóstico por imagem , Lentes Intraoculares/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Resinas Acrílicas/efeitos adversos , Idoso , Segmento Anterior do Olho/patologia , Catarata/complicações , Lentes de Contato Hidrofílicas/efeitos adversos , Diagnóstico Diferencial , Feminino , Humanos , Doenças do Cristalino/complicações , Doenças do Cristalino/patologia , Doenças do Cristalino/cirurgia , Implante de Lente Intraocular/efeitos adversos , Implante de Lente Intraocular/métodos , Cápsula Posterior do Cristalino/patologia , Complicações Pós-Operatórias/patologia , Resultado do Tratamento , Transtornos da Visão/diagnóstico , Transtornos da Visão/cirurgia
5.
Arq. bras. oftalmol ; 82(2): 149-151, Mar.-Apr. 2019. graf
Artigo em Inglês | LILACS | ID: biblio-989392

RESUMO

ABSTRACT - Capsular block syndrome is a rare complication of phacoemulsification surgery with continuous curvilinear capsulorhexis and intraocular lens implantation. Here, we report a case of very late-onset capsular block syndrome that developed 13 years after cataract extraction and present the surgical approach used for its successful treatment.


RESUMO - Síndrome do bloqueio capsular é uma complicação incomum da cirurgia de facoemulsificação com capsulorrexis curvilínea contínua e implante de lente intraocular. Nós relatamos um caso de síndrome de bloqueio capsular de início tardio que se desenvolveu após 13 anos da extração da catarata e apresenta a abordagem cirúrgica utilizada para o sucesso do tratamento.


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Facoemulsificação/efeitos adversos , Capsulotomia Posterior/métodos , Cápsula do Cristalino/cirurgia , Doenças do Cristalino/cirurgia , Doenças do Cristalino/etiologia , Complicações Pós-Operatórias/cirurgia , Síndrome , Acuidade Visual , Resultado do Tratamento , Tomografia de Coerência Óptica , Transtornos de Início Tardio/etiologia , Cápsula do Cristalino/diagnóstico por imagem , Doenças do Cristalino/diagnóstico por imagem , Lentes Intraoculares/efeitos adversos
7.
Arq Bras Oftalmol ; 82(2): 149-151, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30726409

RESUMO

Capsular block syndrome is a rare complication of phacoemulsification surgery with continuous curvilinear capsulorhexis and intraocular lens implantation. Here, we report a case of very late-onset capsular block syndrome that developed 13 years after cataract extraction and present the surgical approach used for its successful treatment.


Assuntos
Cápsula do Cristalino/cirurgia , Doenças do Cristalino/etiologia , Doenças do Cristalino/cirurgia , Facoemulsificação/efeitos adversos , Capsulotomia Posterior/métodos , Feminino , Humanos , Transtornos de Início Tardio/etiologia , Cápsula do Cristalino/diagnóstico por imagem , Doenças do Cristalino/diagnóstico por imagem , Lentes Intraoculares/efeitos adversos , Pessoa de Meia-Idade , Complicações Pós-Operatórias/cirurgia , Síndrome , Tomografia de Coerência Óptica , Resultado do Tratamento , Acuidade Visual
8.
J Cataract Refract Surg ; 45(4): 519-522, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30686702

RESUMO

The implantable collamer lens (ICL) is a widely used posterior chamber phakic intraocular lens that achieves excellent refractive results. Nonetheless, serious postoperative complications related to inadequate vault have been previously reported. Therefore, lens exchange is advised when the vault is out of the recommended ranges. This article presents a case with persistent low vault after lens exchange in which no clinical evidence of crystalline lens opacity or decrease in uncorrected distance visual acuity has been identified during the 6-year clinical follow-up performed to date. Therefore, this suggests that clinical follow-up could be an appropriate approach for patients presenting with low vault, especially those who are older than 40 years and have a history of lens exchange.


Assuntos
Cápsula Anterior do Cristalino/patologia , Doenças do Cristalino/etiologia , Implante de Lente Intraocular/efeitos adversos , Lentes Intraoculares Fácicas/efeitos adversos , Complicações Pós-Operatórias , Adulto , Cápsula Anterior do Cristalino/diagnóstico por imagem , Paquimetria Corneana , Topografia da Córnea , Feminino , Seguimentos , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer/uso terapêutico , Doenças do Cristalino/diagnóstico por imagem , Miopia/cirurgia , Reoperação , Tomografia de Coerência Óptica , Acuidade Visual/fisiologia
10.
J Cataract Refract Surg ; 38(6): 938-40, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22624891

RESUMO

We describe a new approach to treat late-onset capsular distension syndrome in which the fluid in the capsular bag is cloudy and prevents a posterior neodymium:YAG (Nd:YAG) laser capsulotomy. A peripheral laser iridotomy is created through which the anterior lens capsule peripheral to the IOL optic is accessed. This opening in the iris provides an access point through which an anterior Nd:YAG laser capsulotomy can be performed. Following disruption of the anterior lens capsule, the capsular fluid is released into the anterior chamber and absorbed through the inherent drainage system of the eye. This approach avoids the need for a more invasive surgical intervention.


Assuntos
Capsulorrexe/efeitos adversos , Iris/cirurgia , Terapia a Laser , Lasers de Estado Sólido/uso terapêutico , Doenças do Cristalino/cirurgia , Cápsula Posterior do Cristalino/cirurgia , Dilatação Patológica , Humanos , Iridectomia , Doenças do Cristalino/diagnóstico por imagem , Doenças do Cristalino/etiologia , Implante de Lente Intraocular , Masculino , Microscopia Acústica , Pessoa de Meia-Idade , Facoemulsificação , Cápsula Posterior do Cristalino/diagnóstico por imagem , Síndrome
11.
Vestn Oftalmol ; 126(2): 37-42, 2010.
Artigo em Russo | MEDLINE | ID: mdl-21105378

RESUMO

The paper reviews the currently available methods for studying the lens. It describes the anatomic and functional features of the lens and the principles of its examination based on biomicroscopy, photorecording, etc. It also depicts quantitative methods for assessing the properties of the lens: the use of multifunctional devices in which the Scheimpflug principle is realized; methods based on the application of ultrasound energy (A-scanning, B-scanning, biomicroscopy).


Assuntos
Técnicas de Diagnóstico Oftalmológico , Doenças do Cristalino/diagnóstico , Cristalino/anatomia & histologia , Humanos , Doenças do Cristalino/diagnóstico por imagem , Cristalino/fisiologia , Ultrassonografia
12.
Acta Ophthalmol ; 86(5): 565-8, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18752530

RESUMO

PURPOSE: To evaluate the ability of ultrasound biomicroscopy (UBM) to detect abnormalities in the zonular apparatus in unaffected eyes of patients with clinically unilateral exfoliation syndrome (XFS) using a standardized grading system. METHODS: The affected and unaffected eyes of 17 patients with clinically unilateral XFS and 17 eyes of 17 control subjects underwent UBM. Radial sections detailing the lens and zonules at 12:00, 1:30, 3:00, 4:30, 6:00, 7:30, 9:00 and 10:30 clock hours were obtained. The images were graded by a masked, experienced UBM observer using a standardized scoring system based on the zonular appearance (0, none; 1 and 2, uneven or disrupted zonules with or without patchy deposits; 3, diffuse granulation, thick zonules or both; 4, total zonular disruption). Affected meridians were compared by the Friedman test, while distributions of unaffected and affected eyes were compared using the Student t-test. RESULTS: In the control group, 15/17 eyes showed normal zonules; the remaining two eyes showed grade 1 changes in some meridians. The mean grade score was 0.33 [standard deviation (SD) 0.84]. Eyes with XFS had a higher score than control eyes, with a mean score of 14.35 (SD 7.14, P < 0.001, Student t-test). In clinically unaffected fellow eyes, the mean score was 10.53 (SD 7.44), and was less than that of XFS eyes (P = 0.008, Student t-test). Twelve XFS eyes (71%) and six unaffected fellow eyes (35%) had grade 3 or 4 in at least one meridian (P = 0.07, Friedman test). CONCLUSION: Bilateral zonular involvement is present in subjects with clinically unilateral XFS. These zonular changes may be extensive in fellow eyes without clinically evident exfoliation material. UBM assessment of zonular status in fellow eyes prior to cataract extraction may aid in surgical planning.


Assuntos
Síndrome de Exfoliação/diagnóstico por imagem , Doenças do Cristalino/diagnóstico por imagem , Ligamentos/diagnóstico por imagem , Doenças Musculoesqueléticas/diagnóstico por imagem , Idoso , Síndrome de Exfoliação/classificação , Humanos , Cápsula do Cristalino/diagnóstico por imagem , Doenças do Cristalino/classificação , Microscopia Acústica , Doenças Musculoesqueléticas/classificação , Estudos Prospectivos
13.
Acta Ophthalmol Scand ; 85(5): 495-9, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17590201

RESUMO

PURPOSE: To assess zonular appearance using biomicroscopy (UBM) in exfoliation syndrome (XFS). METHODS: Normal eyes and eyes with XFS were enrolled in this prospective, consecutive, comparative cohort study. Following pupillary dilation, XFS patients were classified into three clinical stages (early, moderate or severe) by a single examiner (R.R.). Cross-sectional zonular UBM images were obtained circumferentially at eight evenly spaced locations. Five experienced observers evaluated the images using a standardized scoring system based on the zonular appearance (0, none; 1, early; 2, moderate; 3, severe). The extent of zonular involvement on UBM based on UBM score of all observers was correlated with the clinical stage of XFS using a five-stage classification. RESULTS: We enrolled 44 eyes (44 patients), 11 normal and 33 with XFS (10 early, 10 moderate and 13 severe) [mean age 69.4 +/- 9.9 (SD) years; range 50-87 years]. UBM scores of all observers were significantly different between the normal/early and moderate/severe groups (P < 0.001, t-test). With discriminant analysis, the predicted XFS stage showed good agreement with the clinical staging [all kappa > 0.61, area under receiver operating characteristic (ROC) curve > 0.86]. CONCLUSION: UBM can detect zonular involvement in XFS and may be useful in preoperative planning. This may be important in eyes with posterior synechiae in which a diagnosis and the severity of XFS cannot be determined on slit-lamp examination.


Assuntos
Síndrome de Exfoliação/diagnóstico por imagem , Doenças do Cristalino/diagnóstico por imagem , Ligamentos/diagnóstico por imagem , Microscopia Acústica , Idoso , Idoso de 80 Anos ou mais , Síndrome de Exfoliação/classificação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC
14.
J Cataract Refract Surg ; 31(3): 630-2, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15811757

RESUMO

We report a case of capsular bend-related entrapment of liquefied after-cataract that resulted in late postoperative capsular block syndrome in a 56-year-old man. Slitlamp examination showed a capsular bend formation at the square edge of the optic. Superiorly, leakage in the capsular bend resulted in fluid extending into Soemmering's ring, although communication with the anterior chamber was limited by the capsular bend. Fluid was seen between the lens and posterior capsule.


Assuntos
Cápsula do Cristalino/patologia , Doenças do Cristalino/etiologia , Complicações Pós-Operatórias , Humanos , Doenças do Cristalino/diagnóstico por imagem , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Facoemulsificação , Síndrome , Ultrassonografia
15.
Ophthalmology ; 112(4): 645-9, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15808256

RESUMO

PURPOSE: To study the effect of microkeratome suction on ocular structures during LASIK. DESIGN: Observational, prospective case series. PARTICIPANTS: Twenty-one eyes of 11 patients with myopia or astigmatic myopia (8 females, 3 males) were included. The mean patient age was 36.3 years (median, 37 years; range, 24-48 years), and the mean spherical equivalent was -5.03 diopters (D) (median, -4.63 D; range, -2.38 to -8.38 D). METHODS: We performed preoperative and intraoperative A-scan ultrasonography during application of suction using the Hansatome microkeratome (Bausch & Lomb Surgical, Munich, Germany) to create corneal flaps during LASIK. We also performed preoperative and postoperative B-scan ultrasonography of the posterior ocular segment with special attention to the presence and size of posterior vitreous detachment (PVD). MAIN OUTCOME MEASURES: We measured changes in the axial length, anterior chamber depth, lens thickness, and vitreous distance (distance from the posterior lens capsule to the posterior pole) during application of the microkeratome suction ring and recorded new occurrences of or increases in the size of the PVD after surgery. RESULTS: The lens thickness decreased (mean change, -0.20 mm; P = 0.001; 95% confidence interval [CI], -0.11 to -0.30) in 18 eyes during application of the suction ring. The vitreous distance increased (mean change, 0.20 mm; P = 0.004; 95% CI, 0.08-0.32) in 16 eyes. No statistically significant changes were found in the anterior chamber depth (P = 0.75) or axial length (P = 0.51). After surgery, 3 of 14 eyes (21.4%) experienced PVD that did not have echographic signs of PVD before surgery. Of 7 eyes with preoperative PVD, the PVD enlarged in 1 eye (14.3%). CONCLUSIONS: During application of microkeratome suction, the lens thickness decreases, whereas the vitreous distance increases, suggesting anterior traction on the posterior segment. The relationship between the observed PVD and LASIK merits further investigation.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ/instrumentação , Doenças do Cristalino/etiologia , Sucção/efeitos adversos , Corpo Vítreo/patologia , Descolamento do Vítreo/etiologia , Adulto , Câmara Anterior/patologia , Câmara Anterior/ultraestrutura , Astigmatismo/cirurgia , Feminino , Humanos , Doenças do Cristalino/diagnóstico por imagem , Cristalino/patologia , Cristalino/ultraestrutura , Masculino , Pessoa de Meia-Idade , Miopia/cirurgia , Estudos Prospectivos , Ultrassonografia , Corpo Vítreo/ultraestrutura , Descolamento do Vítreo/diagnóstico por imagem
16.
J Cataract Refract Surg ; 29(2): 405-6, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12648659

RESUMO

We report an unusual case of an eye with 2 congenital crystalline lenses; ie, a duplicated lens. The horizontal axis of the eye was obliquely placed. One lens was situated in the upper temporal quadrant and the other, in the lower nasal quadrant. One lens was larger than the other.


Assuntos
Anormalidades do Olho/diagnóstico , Doenças do Cristalino/congênito , Cristalino/anormalidades , Adulto , Feminino , Humanos , Doenças do Cristalino/diagnóstico por imagem , Cristalino/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Ultrassonografia
19.
Ophthalmic Surg Lasers ; 32(3): 239-42, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11371092

RESUMO

Intralenticular abscess is a rare entity and has been infrequently reported after surgery, metastatic infection, or trauma. We report a case of post traumatic lens abscess with low-grade endophthalmitis following a penetrating eye injury with a splinter of wood. The patient was successfully treated with a pars plana lensectomy and vitrectomy. Despite thorough microbiological investigations, no causative organism could be isolated.


Assuntos
Abscesso/cirurgia , Endoftalmite/cirurgia , Ferimentos Oculares Penetrantes/cirurgia , Doenças do Cristalino/cirurgia , Cristalino/lesões , Cristalino/cirurgia , Vitrectomia , Abscesso/diagnóstico por imagem , Abscesso/etiologia , Adolescente , Doença Crônica , Endoftalmite/diagnóstico por imagem , Endoftalmite/etiologia , Ferimentos Oculares Penetrantes/diagnóstico por imagem , Ferimentos Oculares Penetrantes/etiologia , Humanos , Doenças do Cristalino/diagnóstico por imagem , Doenças do Cristalino/etiologia , Cristalino/diagnóstico por imagem , Masculino , Ultrassonografia , Acuidade Visual , Madeira
20.
Ophthalmology ; 107(5): 902-8, 2000 May.
Artigo em Inglês | MEDLINE | ID: mdl-10811082

RESUMO

OBJECTIVE: To determine the causes of postoperative myopia associated with capsular bag distention syndrome (CBDS) and characterize the associated findings. DESIGN: Prospective, multicenter, nonrandomized, comparative (self-controlled) trial. PARTICIPANTS: Six eyes from six patients had CBDS develop after phacoemulsification and posterior chamber intraocular lens implantation. METHODS: Keratometric values, axial length, visual acuity, and manifest refraction were assessed in each eye. Using 20-MHz (I3SYSTEM-ABD, Innovative Imaging Inc, Sacramento, CA) and 50-MHz (Ultrasound Biomicroscope, Zeiss Humphrey Systems, Dublin, CA) ultrasonographic probes, images and measurements of the anterior segment were obtained. After neodymium:yttrium-aluminum-garnet (Nd:YAG) capsulotomy, these measures were repeated and correlated with predicted and actual refractive changes. MAIN OUTCOME MEASURES: Uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), manifest refraction, and anterior chamber depth before and after treatment of CBDS. RESULTS: Although intended postoperative refraction averaged -0.58 diopters (D) (range, -0.12 to -1.63 D), eyes with CBDS had an average spherical equivalent refraction of -2.35 D (range, +0.13 to -4.50 D), P < 0.05 (one-tailed, paired t test). BCVA averaged 20/24 (range, 20/15-20/40-1), but UCVA averaged 20/133 (range, 20/60 to 20/400). Average distance from the corneal surface to the anterior intraocular lens (IOL) optic surface was 3.55 mm in eyes with CBDS, and 4.30 mm after Nd:YAG capsulotomy. Posterior movement of the IOL optic after capsulotomy accounted for 1.23 D of hyperopic shift or 82% of the CBDS-induced myopia. Treatment of CBDS resulted in both improved UCVA and BCVA. Nd:YAG capsulotomy also released the colloidal suspension within the capsular bag posterior to the IOL optic. The incidence of CBDS was 0.3% in one of the practices reviewed. CONCLUSIONS: Capsular bag distention syndrome includes unexpected myopia and poor UCVA after cataract surgery with lens implantation in cases involving a continuous capsulorhexis. A dramatic posterior distention of the posterior capsule is observed, as well as anterior chamber shallowing, tight apposition of the iris to the IOL, and anterior bowing of the iris. A slightly turbid colloidal suspension behind the IOL implant and late posterior capsular fibrosis are also observed. Timely treatment of CBDS can correct unwanted myopia, improve UCVA and BCVA, and restore normal anatomic relationships in the eye.


Assuntos
Cápsula do Cristalino/diagnóstico por imagem , Doenças do Cristalino/diagnóstico por imagem , Implante de Lente Intraocular/efeitos adversos , Miopia/diagnóstico por imagem , Facoemulsificação/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Câmara Anterior/diagnóstico por imagem , Câmara Anterior/patologia , Capsulorrexe/efeitos adversos , Dilatação Patológica/diagnóstico por imagem , Dilatação Patológica/etiologia , Humanos , Recém-Nascido , Cápsula do Cristalino/patologia , Cápsula do Cristalino/cirurgia , Doenças do Cristalino/etiologia , Doenças do Cristalino/cirurgia , Pessoa de Meia-Idade , Miopia/etiologia , Estudos Prospectivos , Refração Ocular , Síndrome , Ultrassonografia , Acuidade Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...