Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Minim Invasive Gynecol ; 25(1): 84-92, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28807810

RESUMO

STUDY OBJECTIVE: To evaluate a unique learning system for uterine artery embolization (UAE) and examine its feasibility and clinical outcomes for the treatment of symptomatic uterine leiomyomas and adenomyosis when performed by obstetrician-gynecologists in cooperation with interventional radiologists (IVRs). DESIGN: Retrospective study (Canadian Task Force classification II-2). SETTING: University hospital. PATIENTS: One hundred seventy-three patients who underwent UAE for symptomatic leiomyomas and adenomyosis. INTERVENTIONS: We examined the medical records of patients who underwent UAE for symptomatic uterine leiomyomas and adenomyosis at our department between 2003 and 2012 using our learning system for UAE for obstetrician-gynecologists in cooperation with IVRs. The charts of all patients were reviewed, and data on etiologic factors, past medical history of leiomyomas and adenomyosis, symptoms, details of UAE, and clinical outcomes after UAE were extracted. MEASUREMENTS AND MAIN RESULTS: A total of 173 patients who underwent 177 UAEs were identified, including 4 patients who underwent embolization twice because of primary treatment failure or symptom recurrence. During the study period, 2 gynecologists successfully acquired endovascular skills. The technical success rate was 97.7% (174 of 177). The duration of fluoroscopy in procedures performed by obstetrician-gynecologists who acquired endovascular skills was not significantly different from that in procedures performed by IVRs at our institution; however, this duration was significantly longer in procedures performed by obstetrician-gynecologists who did not have sufficient experience with our learning protocol for UAE because of inadequate live observation of UAEs performed by skilled IVRs. Complications that necessitated discontinuation of the procedure occurred in 2.3% of cases (4 of 177). The clinical outcomes were similar to those reported in previous studies. Adverse events after UAE included myeloid passages in 7.0% (11 of 158), infections in 2.5% (4 of 158), vaginal discharge in 2.5% of patients with leiomyomas (4 of 158), and vaginal discharge in 7.1% of patients with adenomyosis (1 of 14). All the adverse events were adequately treated by the obstetrician-gynecologists themselves. The timing of hysterectomy due to complications or recurrence of symptoms after UAE varied widely. CONCLUSION: UAE performed by obstetrician-gynecologists in cooperation with radiologists can be achieved safely and successfully with acceptable clinical outcomes. Live observation of the procedure performed by skilled IVRs is essential to improving the skills and reducing the fluoroscopic time of obstetrician-gynecologists.


Assuntos
Adenomiose/cirurgia , Leiomioma/cirurgia , Radiologia Intervencionista/educação , Treinamento por Simulação/métodos , Embolização da Artéria Uterina/educação , Neoplasias Uterinas/cirurgia , Adenomiose/diagnóstico , Adulto , Comportamento Cooperativo , Feminino , Ginecologia/educação , Humanos , Histerectomia , Leiomioma/complicações , Leiomioma/diagnóstico , Pessoa de Meia-Idade , Obstetrícia/educação , Equipe de Assistência ao Paciente , Radiologistas/educação , Estudos Retrospectivos , Cirurgia Assistida por Computador/educação , Cirurgia Assistida por Computador/métodos , Falha de Tratamento , Resultado do Tratamento , Embolização da Artéria Uterina/métodos , Neoplasias Uterinas/diagnóstico
2.
J Am Coll Radiol ; 11(5): 471-6, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24529983

RESUMO

RATIONALE AND OBJECTIVES: To measure the impact of 1-year interventional fellowship training on fluoroscopic time and contrast media utilization in uterine artery embolization (UAE). MATERIALS AND METHODS: Retrospective single institution analysis of 323 consecutive UAEs performed by 12 interventional fellows using a standardized protocol. Fluoroscopy time and contrast media volume were recorded for each patient and correlated with stage of fellowship training. Preprocedure uterine volume (using MRI or ultrasound) was used as a measure of procedural complexity. Regression analysis was conducted per trainee factoring in duration of training, procedure number, supervising radiologist, uterine volume, and outcome variables of fluoroscopy time and contrast media volume. RESULTS: Median number of patients treated per trainee was 27 (range, 16-43) with mean fluoroscopic time 24.5 minutes (range, 4-90 min) and mean contrast volume 190 mL (range, 50-320 mL). Increasing uterine volume had no significant effect (P > .05) on fluoroscopic time but significantly increased (P < .001) contrast media volume. Significant training effect was identified with decrease in fluoroscopic time (P < .001) and decrease in contrast volume (P = .02) over training. Over the course of a 1-year fellowship, these summed to a decrease of 12 minutes in UAE fluoroscopy time and 17 mL less contrast. CONCLUSION: A significant (P < .05) training effect that is clinically relevant was demonstrated over the course of a yearlong interventional radiology fellowship program in performance of a standardized protocol for UAE. This data supports fellowship training as a basis for UAE credentialing and privileging.


Assuntos
Competência Clínica , Educação de Pós-Graduação em Medicina/métodos , Bolsas de Estudo , Radiologia Intervencionista/educação , Embolização da Artéria Uterina/educação , Meios de Contraste/administração & dosagem , Avaliação Educacional , Feminino , Fluoroscopia , Humanos , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Ácidos Tri-Iodobenzoicos , Ultrassonografia de Intervenção , Embolização da Artéria Uterina/normas
3.
Vascular ; 20(5): 268-72, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22962044

RESUMO

Uterine artery embolization (UAE) has been performed by interventional radiology since the 1990s for symptomatic uterine fibroids with considerable success. Endovascular-trained vascular surgeons possess the necessary skills to successfully perform this procedure after an adequate but brief training period. Fourteen successful UAE procedures were performed by two vascular surgeons over a one-year period. Indications for the procedures were bleeding (12/14 patients, 86%), pain/bloating/pressure (13/14 patients, 93%) and dyspareunia (2/14 patients, 14%). All patients were initially evaluated by a gynecologist and referred for this procedure. Complications were minor and limited. Clinical follow-up demonstrated near-complete to complete symptom resolution in all but one patient for a 93% short-term success rate. Follow-up ultrasound studies demonstrated a reduction in the uterine fibroid size in all patients three months or more postprocedure. The mean fibroid size reduction was 4.07-3.26 cm (20%), P < 0.005. UAE is a procedure of proven benefit, well-matched to many vascular surgeons' skills and practice. Up to this point, few vascular surgeons have incorporated this endovascular procedure into their practices. This initial and somewhat limited study demonstrates one vascular surgery group's early success with this procedure.


Assuntos
Leiomioma/terapia , Leiomiomatose/terapia , Especialidades Cirúrgicas , Embolização da Artéria Uterina , Artéria Uterina , Neoplasias Uterinas/terapia , Procedimentos Cirúrgicos Vasculares , Competência Clínica , Educação de Pós-Graduação em Medicina , Feminino , Humanos , Curva de Aprendizado , Leiomioma/irrigação sanguínea , Leiomioma/diagnóstico por imagem , Leiomiomatose/irrigação sanguínea , Leiomiomatose/diagnóstico por imagem , New York , Radiografia Intervencionista/normas , Encaminhamento e Consulta , Estudos Retrospectivos , Especialidades Cirúrgicas/educação , Especialidades Cirúrgicas/normas , Resultado do Tratamento , Artéria Uterina/diagnóstico por imagem , Embolização da Artéria Uterina/educação , Embolização da Artéria Uterina/normas , Neoplasias Uterinas/irrigação sanguínea , Neoplasias Uterinas/diagnóstico por imagem , Procedimentos Cirúrgicos Vasculares/educação , Procedimentos Cirúrgicos Vasculares/normas
5.
J Vasc Interv Radiol ; 23(10): 1361-6.e2, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22854318

RESUMO

PURPOSE: To assess the face and content validity of a novel, full physics, full procedural, virtual reality simulation housed in a hybrid procedure suite. METHODS AND MATERIALS: After completing 60 minutes of hands-on training in uterine artery embolization and coronary angioplasty, 24 radiologists and 18 cardiologists with mean 10 years of endovascular experience assessed the functionality of a comprehensive hybrid procedure suite simulation (Orcamp; Orzone, Gothenburg, Sweden). RESULTS: C-arm and operating table functionality and realism were reliably (α = 0.0.89-0.92) rated highly (80/100). Performance realism of the catheter, guide wire, fluoroscopy image, electrocardiogram, and vital signs readout also reliably and statistically significantly predicted subjects' overall positive assessment (mean = 87/100) of the simulation experience in a multiple regression model (α = .83; r = 0.85 and r(2) = 0.67; P < .0001). CONCLUSIONS: This study reports a quantitative evaluation of a comprehensive simulation of an authentic procedure suite for image-guided intravascular procedures. This new facility affords the opportunity for trainers to provide higher fidelity training of operative technical, procedural, and management skills in the realistic context of a complete procedure suite with all its complexities and potential distractions.


Assuntos
Angioplastia/educação , Simulação por Computador , Instrução por Computador , Educação de Pós-Graduação em Medicina/métodos , Embolização da Artéria Uterina/educação , Adulto , Angioplastia/instrumentação , Cateterismo Cardíaco , Cateterismo Periférico , Competência Clínica , Instrução por Computador/instrumentação , Eletrocardiografia , Desenho de Equipamento , Feminino , Fluoroscopia , Humanos , Pessoa de Meia-Idade , Radiografia Intervencionista , Análise e Desempenho de Tarefas , Embolização da Artéria Uterina/instrumentação
6.
Artigo em Inglês | MEDLINE | ID: mdl-19255927

RESUMO

This study addresses endovascular training using simulators for uterine artery embolization. A review of endovascular skill training for surgeons using simulators was performed. Surgeons possess varying levels of proficiency in endovascular techniques. A simulator will improve endovascular skills in the following areas: C-arm image intensifier use, catheter selection and manipulation, understanding of the pelvic anatomy, and technique of embolization. Surgeons may gain realistic experience on the simulator prior to entry into the cath lab or procedure room. Using a simulator, surgeons can learn valuable endovascular skills necessary for successful performance of uterine artery embolization.


Assuntos
Competência Clínica , Simulação por Computador , Embolização da Artéria Uterina/educação , Cateterismo/métodos , Instrução por Computador/métodos , Feminino , Humanos , Embolização da Artéria Uterina/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...