Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23.234
Filtrar
1.
J Med Microbiol ; 73(6)2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38935078

RESUMO

Introduction. Avian reovirus (ARV) is associated with arthritis/tenosynovitis and malabsorption syndrome in chickens. The σC and σB proteins, both exposed to the virus capsid, are highly immunogenic and could form the basis for diagnostic devices designed to assess the immunological status of the flock.Gap Statement. Commercial ARV ELISAs cannot distinguish between vaccinated and infected animals and might not detect circulating ARV strains.Aim. We aimed to develop a customized test to detect the circulating field ARV strains as well as distinguish between vaccinated and unvaccinated animals.Methodology. We developed ELISA assays based on recombinant (r) σB, σC and the nonstructural protein σNS and tested them using antisera of vaccinated and unvaccinated chickens as well as negative controls. Fragments of σB and σC proteins were also used to study regions that could be further exploited in diagnostic tests.Results. Vaccinated and unvaccinated birds were positive by commercial ELISA, with no difference in optical density values. In contrast, samples of unvaccinated animals showed lower absorbance in the rσB and rσC ELISA tests and higher absorbance in the rσNS ELISA test than the vaccinated animals. Negative control samples were negative in all tests. Fragmentation of σB and σC proteins showed that some regions can differentiate between vaccinated and unvaccinated animals. For example, σB amino acids 128-179 (σB-F4) and σC amino acids 121-165 (σC-F4) exhibited 85 and 95% positivity among samples of vaccinated animals but only 5% and zero positivity among samples of unvaccinated animals, respectively.Conclusion. These data suggest that unvaccinated birds might have been exposed to field strains of ARV. The reduction in absorbance in the recombinant tests possibly reflects an increased specificity of our test since unvaccinated samples showed less cross-reactivity with the vaccine proteins immobilized on ELISAs. The discrepant results obtained with the protein fragment tests between vaccinated and unvaccinated animals are discussed in light of the diversity between ARV strains.


Assuntos
Galinhas , Ensaio de Imunoadsorção Enzimática , Orthoreovirus Aviário , Doenças das Aves Domésticas , Proteínas Recombinantes , Infecções por Reoviridae , Animais , Orthoreovirus Aviário/imunologia , Orthoreovirus Aviário/genética , Orthoreovirus Aviário/isolamento & purificação , Ensaio de Imunoadsorção Enzimática/métodos , Ensaio de Imunoadsorção Enzimática/veterinária , Infecções por Reoviridae/veterinária , Infecções por Reoviridae/diagnóstico , Doenças das Aves Domésticas/virologia , Doenças das Aves Domésticas/diagnóstico , Proteínas Recombinantes/imunologia , Anticorpos Antivirais/sangue , Proteínas do Capsídeo/imunologia , Proteínas do Capsídeo/genética , Proteínas Virais/imunologia , Proteínas Virais/genética
2.
Viruses ; 16(6)2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38932207

RESUMO

The serological surveillance of bluetongue in bulk tank milk is an efficient and cost-effective method for the early detection of bluetongue virus incursions in unvaccinated free areas of the disease. In addition, the availability of standardized and reliable reagents and refined diagnostic procedures with high sensitivity and specificity are essential for surveillance purposes. However, no available reference materials for bluetongue virus serological surveillance in bulk tank milk exist. This study shows the production and characterization of reference material for the implementation of a commercially available bluetongue milk ELISA test in official laboratories, as well as the evaluation of a procedure to increase the sensitivity in samples with low levels of antibodies. This procedure, based on milk protein concentration, allowed us to notably increase the ELISA test's analytical sensitivity, which is useful for milk samples from farms with low within-herd prevalence or pools of bulk tank milk samples. The standardized milk reference material produced here, together with the evaluated procedure to improve analytical sensitivity, could be applied as tools to ensure an accurate diagnosis by official laboratories in bluetongue unvaccinated free areas.


Assuntos
Vírus Bluetongue , Bluetongue , Ensaio de Imunoadsorção Enzimática , Proteínas do Leite , Leite , Sensibilidade e Especificidade , Animais , Leite/virologia , Leite/química , Bluetongue/diagnóstico , Bluetongue/virologia , Vírus Bluetongue/imunologia , Vírus Bluetongue/isolamento & purificação , Ensaio de Imunoadsorção Enzimática/métodos , Ovinos , Bovinos , Proteínas do Leite/análise , Proteínas do Leite/imunologia , Anticorpos Antivirais/sangue , Testes Sorológicos/métodos , Testes Sorológicos/normas , Padrões de Referência , Feminino
3.
Viruses ; 16(6)2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38932244

RESUMO

Recently, respiratory syncytial virus (RSV) vaccines based on the prefusion F (pre-F) antigen were approved in the United States. We aimed to develop an enzyme-linked immunosorbent assay (ELISA)-based protocol for the practical and large-scale evaluation of RSV vaccines. Two modified pre-F proteins (DS-Cav1 and SC-TM) were produced by genetic recombination and replication using an adenoviral vector. The protocol was established by optimizing the concentrations of the coating antigen (pre-F proteins), secondary antibodies, and blocking buffer. To validate the protocol, we examined its accuracy, precision, and specificity using serum samples from 150 participants across various age groups and the standard serum provided by the National Institute of Health. In the linear correlation analysis, coating concentrations of 5 and 2.5 µg/mL of DS-Cav1 and SC-TM showed high coefficients of determination (r > 0.90), respectively. Concentrations of secondary antibodies (alkaline phosphatase-conjugated anti-human immunoglobulin G, diluted 1:2000) and blocking reagents (5% skim milk/PBS-T) were optimized to minimize non-specific reactions. High accuracy was observed for DS-Cav1 (r = 0.90) and SC-TM (r = 0.86). Further, both antigens showed high precision (coefficient of variation < 15%). Inhibition ELISA revealed cross-reactivity of antibodies against DS-Cav1 and SC-TM, but not with the attachment (G) protein.


Assuntos
Anticorpos Antivirais , Ensaio de Imunoadsorção Enzimática , Infecções por Vírus Respiratório Sincicial , Vacinas contra Vírus Sincicial Respiratório , Vírus Sincicial Respiratório Humano , Ensaio de Imunoadsorção Enzimática/métodos , Ensaio de Imunoadsorção Enzimática/normas , Humanos , Infecções por Vírus Respiratório Sincicial/prevenção & controle , Infecções por Vírus Respiratório Sincicial/imunologia , Infecções por Vírus Respiratório Sincicial/diagnóstico , Anticorpos Antivirais/sangue , Anticorpos Antivirais/imunologia , Vacinas contra Vírus Sincicial Respiratório/imunologia , Vírus Sincicial Respiratório Humano/imunologia , Lactente , Pré-Escolar , Adulto , Criança , Adolescente , Pessoa de Meia-Idade , Adulto Jovem , Feminino , Sensibilidade e Especificidade , Antígenos Virais/imunologia , Masculino , Proteínas Virais de Fusão/imunologia , Idoso
4.
Medicine (Baltimore) ; 103(24): e38539, 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38875396

RESUMO

Orexin in cerebrospinal fluid (CSF) is a neuropeptide synthesized by a cluster of neurons in the lateral hypothalamus. It mainly functions to maintain arousal, regulate feeding, and participate in reward mechanisms. Radioimmunoassay (RIA) and enzyme-linked immunosorbent assay (ELISA) can detect CSF orexin. At present, RIA is widely used but is limited by various conditions, which is not conducive to its widespread development. We aimed to determine whether ELISA can replace RIA in detecting orexin in CSF. We investigated the results of 20 patients with central disorders of hypersomnolence, including 11 with narcolepsy type 1, 2 with narcolepsy type 2, 5 with idiopathic hypersomnia, and 2 with other causes of somnolence. RIA and ELISA were used to detect CSF orexin, and P values <.05 were considered to be significant. In the narcolepsy and non-narcolepsy type 1 groups, there was no correlation between the RIA and ELISA results (P > .05). In the narcolepsy type 1 group, the ELISA and RIA results were significantly different (P < .05), but this was not observed in the non-narcolepsy type 1 group (P > .05). The accuracy of ELISA to detect CSF orexin was lower than that of RIA (P < .05). ELISA cannot replace RIA in the measurement of CSF orexin, and RIA is recommended as the first choice when narcolepsy is suspected.


Assuntos
Ensaio de Imunoadsorção Enzimática , Narcolepsia , Orexinas , Radioimunoensaio , Humanos , Orexinas/líquido cefalorraquidiano , Narcolepsia/líquido cefalorraquidiano , Narcolepsia/diagnóstico , Ensaio de Imunoadsorção Enzimática/métodos , Masculino , Radioimunoensaio/métodos , Feminino , Adulto , Pessoa de Meia-Idade , Adulto Jovem , Adolescente
5.
J Vector Borne Dis ; 61(2): 203-210, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38922654

RESUMO

BACKGROUND OBJECTIVES: Plasmodium knowlesi, a simian malaria species, is now known to infect humans. Due to disadvantages in the current diagnosis methods, many efforts have been placed into developing new methods to diagnose the disease. This study assessed the ability of the PkRAP-1 sandwich enzyme-linked immunosorbent (ELISA) to detect P knowlesi antigens in whole blood specimens. METHODS: Western blot assay was conducted to evaluate the ability of raised mouse and rabbit anti-PkRAP-1 polyclonal antibodies to bind to the native proteins in P. knowlesi lysate. The polyclonal antibodies were then used in sandwich ELISA to detect P. knowlesi. In the sandwich ELISA, mouse and rabbit polyclonal antibodies were used as the capture and detection antibodies, respectively. The limit of detection (LOD) of the assay was determined using P. knowlesi A1H1 culture and purified recombinant PkRAP-1. RESULTS: Western blot results showed positive reactions towards the proteins in P. knowlesi lysate. The LOD of the assay from three technical replicates was 0.068% parasitaemia. The assay performance in detecting P. knowlesi was 83% sensitivity and 70% specificity with positive and negative predictive values of 74% and 80%, respectively. The anti-PkRAP-1 polyclonal antibodies did not cross-react with P. falciparum and healthy samples, but P. vivax by detecting all 12 samples. INTERPRETATION CONCLUSION: PkRAP-1 has the potential as a biomarker for the development of a new diagnostic tool for P. knowlesi detection. Further studies need to be conducted to establish the full potential of the usage of anti-PkRAP-1 antibodies for P. knowlesi detection.


Assuntos
Anticorpos Antiprotozoários , Antígenos de Protozoários , Ensaio de Imunoadsorção Enzimática , Malária , Plasmodium knowlesi , Proteínas de Protozoários , Sensibilidade e Especificidade , Plasmodium knowlesi/imunologia , Ensaio de Imunoadsorção Enzimática/métodos , Animais , Malária/diagnóstico , Malária/sangue , Anticorpos Antiprotozoários/sangue , Coelhos , Camundongos , Proteínas de Protozoários/imunologia , Humanos , Antígenos de Protozoários/imunologia , Antígenos de Protozoários/sangue , Western Blotting/métodos , Limite de Detecção
6.
Methods Mol Biol ; 2810: 301-316, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38926287

RESUMO

Cell-surface receptors can be difficult to express and purify for structural and biochemical studies due to low expression levels, misfolding, aggregation, and instability. Cell-surface receptor ectodomains are more amenable to large-scale production, but this requires designing and testing various truncation constructs. However, since each protein is unique, testing these constructs individually for many targets is a time-consuming process. In this context, we present a high-throughput ELISA fluorescence approach that allows the rapid assessment of numerous recombinant constructs simultaneously. Cell-surface ectodomains are expressed in small scale, enzymatically biotinylated, and detected using a C-terminal His-tag. As an example, we tested the expression of truncation constructs for the neurexin, neuroligin, and latrophilin families and show that the small-scale ELISA allowed us to prioritize well-expressing construct for large-scale production. By employing this method, one can efficiently detect clones with low expression levels, streamlining the process and saving valuable time in identifying optimal candidates for further study.


Assuntos
Ensaio de Imunoadsorção Enzimática , Ensaios de Triagem em Larga Escala , Humanos , Ensaio de Imunoadsorção Enzimática/métodos , Ensaios de Triagem em Larga Escala/métodos , Proteínas de Membrana/genética , Proteínas de Membrana/metabolismo , Domínios Proteicos , Proteínas Recombinantes/genética , Proteínas Recombinantes/metabolismo , Proteínas Recombinantes/isolamento & purificação , Células HEK293 , Expressão Gênica
7.
J Immunol Methods ; 530: 113697, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38823576

RESUMO

Porcine reproductive and respiratory syndrome (PRRS) caused by the PRRS virus (PRRSV) is one of the most severe swine diseases causing great economic losses for the international swine industry. Non-structural protein 4 (NSP4) is critical to the life cycle of PRRSV and contains dominant B cell epitopes. This study prepared a monoclonal antibody against Nsp4, and 2D11, which contained the sequence 138KQGGGIVTRPSGQFCN153, was confirmed as the epitope. A 2D11-based double antibody sandwich enzyme-linked immunosorbent assay (dasELISA) was next developed with a cut value of 0.1987. A total of 1354 pig serum samples were detected by dasELISA and compared to a commercial ELISA kit (N-coated iELISA), resulting in a positive coincidence rate of 98.8% and negative coincidence rate of 96.9%. A total of 119 sera were positive by dasELISA while negative by iELISA. Higher positive rates by dasELISA were found in pig farms where PRRSV antibody levels varied widely. These results indicated that the dasELISA was a useful tool to detect PRRSV antibody in clinical samples.


Assuntos
Anticorpos Monoclonais , Anticorpos Antivirais , Ensaio de Imunoadsorção Enzimática , Síndrome Respiratória e Reprodutiva Suína , Vírus da Síndrome Respiratória e Reprodutiva Suína , Proteínas não Estruturais Virais , Vírus da Síndrome Respiratória e Reprodutiva Suína/imunologia , Animais , Ensaio de Imunoadsorção Enzimática/métodos , Suínos , Anticorpos Monoclonais/imunologia , Síndrome Respiratória e Reprodutiva Suína/imunologia , Síndrome Respiratória e Reprodutiva Suína/diagnóstico , Síndrome Respiratória e Reprodutiva Suína/sangue , Anticorpos Antivirais/sangue , Anticorpos Antivirais/imunologia , Proteínas não Estruturais Virais/imunologia , Epitopos Imunodominantes/imunologia , Epitopos de Linfócito B/imunologia
8.
Anal Methods ; 16(25): 4074-4082, 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38855900

RESUMO

Prothioconazole and its metabolite are considered a potential threat to human health and environmental safety. Thus, the development of a sensitive and rapid detection method for prothioconazole is crucial to ensure the safety of agricultural products. In this study, a new hapten of prothioconazole was designed and synthesized, and a selective polyclonal antibody with high affinity against prothioconazole was produced, which was obtained from immunized New Zealand white rabbits. Based on the polyclonal antibody, an indirect competitive enzyme-linked immunosorbent assay (ic-ELISA) and indirect competitive chemiluminescence enzyme immunoassay (ic-CLEIA) were developed for detecting prothioconazole pesticides. Under optimized experimental conditions, the limit of quantification (LOQ) values for ic-CLEIA and ic-ELISA were 1.8 and 10.7 ng mL-1, respectively. The results demonstrated that the sensitivity (LOQ) achieved by ic-CLEIA was more than five times higher compared to that obtained with ic-ELISA. In addition, the recoveries obtained by adding standard prothioconazole to wheat grain, soybean, and pond water samples were in the range of 81.9 to 104.7% for ic-ELISA and 89.0 to 118.0% for ic-CLEIA.


Assuntos
Anticorpos , Ensaio de Imunoadsorção Enzimática , Glycine max , Triazóis , Triticum , Animais , Ensaio de Imunoadsorção Enzimática/métodos , Triazóis/análise , Triazóis/química , Triticum/química , Glycine max/química , Coelhos , Anticorpos/imunologia , Anticorpos/química , Poluentes Químicos da Água/análise , Grão Comestível/química , Água Doce/análise , Limite de Detecção , Medições Luminescentes/métodos , Fungicidas Industriais/análise , Haptenos/química , Haptenos/imunologia
9.
Anal Methods ; 16(25): 4060-4065, 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38873980

RESUMO

Methyl parathion, a highly toxic, efficient, and persistent organophosphorus pesticide, is widely used in China. Sibutramine, a non-amphetamine central nervous system depressant, helps lose weight by disrupting hormone regulation, stimulating sympathetic nerves, and suppressing appetite. However, some unethical businesses fail to properly handle raw materials in foods like apple cider vinegar, leading to residual methyl parathion in apples or illegal excessive addition of sibutramine. Therefore, it is imperative to develop an immunoassay for the rapid detection of methyl parathion and sibutramine. The corresponding two haptens were prepared and coupled with the carrier proteins according to methyl parathion-sulfur-bovine serum protein (BSA)/chicken ovalbumin (OVA)-sibutramine (20 : 1 : excess, 15 : 1 : excess, 10 : 1 : excess, and 5 : 1 : excess), and sibutramine-BSA/OVA-methyl parathion (20 : 1 : excess, 10 : 1 : excess: 5 : 1 : excess, and 0 : 1 : excess). The result shows that the inhibition rate of the antibody obtained by methyl parathion-BSA/OVA-sibutramine (20 : 1 : excess) was higher than that of sibutramine-BSA/OVA-methyl parathion, which was 67.93%, and the concentration of methyl parathion was 8.65 ng mL-1 at this inhibition rate. Thus, methyl parathion-BSA/OVA-sibutramine (8.65 : 1 : excess) and the corresponding antibodies were selected for subsequent method establishment. By changing the concentration of the coating and antibody, the inhibition rate was found when the coating was 0.125 ng mL-1 and the antibody was diluted 4000 times. The antibody was used to develop a standard curve for the detection of sibutramine at the half-maximum inhibitory concentration (IC50) is 4.59 ng mL-1, the limit of detection (IC10) is 2.21 ng mL-1, the detection range is 2.89 to 7.28 ng mL-1, methyl p-phosphorus at the half-maximum inhibitory concentration (IC50) is 15.34 ng mL-1, the limit of detection (IC10) is 0.42 ng mL-1, the detection range is ng mL-1. Under these conditions, the recovery rate was between 88% and 102%, within reasonable limits, indicating the successful establishment of a rapid enzyme-linked ELISA assay.


Assuntos
Ciclobutanos , Ensaio de Imunoadsorção Enzimática , Malus , Metil Paration , Ciclobutanos/química , Ensaio de Imunoadsorção Enzimática/métodos , Malus/química , Metil Paration/análise , Ácido Acético/química , Depressores do Apetite/análise , Depressores do Apetite/química , Contaminação de Alimentos/análise , Animais , Limite de Detecção
10.
J Vis Exp ; (207)2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38856223

RESUMO

8-Oxo-7,8-dihydro-2'-deoxyguanosine (8-oxo-dG) base is the predominant form of commonly observed DNA oxidative damage. DNA impairment profoundly impacts gene expression and serves as a pivotal factor in stimulating neurodegenerative disorders, cancer, and aging. Therefore, precise quantification of 8-oxoG has clinical significance in the investigation of DNA damage detection methodologies. However, at present, the existing approaches for 8-oxoG detection pose challenges in terms of convenience, expediency, affordability, and heightened sensitivity. We employed the sandwich enzyme-linked immunosorbent assay (ELISA) technique, a highly efficient and swift colorimetric method, to detect variations in 8-oxo-dG content in MCF-7 cell samples stimulated with different concentrations of hydrogen peroxide (H2O2). We determined the concentration of H2O2 that induced oxidative damage in MCF-7 cells by detecting its IC50 value in MCF-7 cells. Subsequently, we treated MCF-7 cells with 0, 0.25, and 0.75 mM H2O2 for 12 h and extracted 8-oxo-dG from the cells. Finally, the samples were subjected to ELISA. Following a series of steps, including plate spreading, washing, incubation, color development, termination of the reaction, and data collection, we successfully detected changes in the 8-oxo-dG content in MCF-7 cells induced by H2O2. Through such endeavors, we aim to establish a method to evaluate the degree of DNA oxidative damage within cell samples and, in doing so, advance the development of more expedient and convenient approaches for DNA damage detection. This endeavor is poised to make a meaningful contribution to the exploration of associative analyses between DNA oxidative damage and various domains, including clinical research on diseases and the detection of toxic substances.


Assuntos
8-Hidroxi-2'-Desoxiguanosina , Dano ao DNA , Ensaio de Imunoadsorção Enzimática , Peróxido de Hidrogênio , Estresse Oxidativo , Humanos , Dano ao DNA/efeitos dos fármacos , Células MCF-7 , Ensaio de Imunoadsorção Enzimática/métodos , Peróxido de Hidrogênio/farmacologia , Estresse Oxidativo/efeitos dos fármacos , Desoxiguanosina/análogos & derivados , Desoxiguanosina/análise
11.
Front Cell Infect Microbiol ; 14: 1374560, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38873096

RESUMO

Introduction: As a contagious and chronic disease in the livestock industry, Paratuberculosis is a significant threat to dairy herds' genetic and economic resources. Due to intensive breeding and high production of dairy cattle, the incidence and prevalence are higher. Developing non-destructive diagnostic methods for the early detection and identification of healthy animals is paramount for breeding programs. Conventional methods are almost entirely destructive, have low accuracy, lack precision, and are time-consuming. Near-infrared spectroscopy (NIRS) and aquaphotomics can detect changes in biofluids and thus have the potential to diagnose disease. This study aimed to investigate the diagnostic ability of NIRS and aquaphotomics for Paratuberculosis in dairy cattle. Methods: Blood plasma from dairy cattle was collected in the NIR range (1,300 nm to 1,600 nm) 60 days before and 100 days to 200 days after calving in two groups, positive and negative, using the same consecutive enzyme-linked immunosorbent assay test results three times as a reference test. Results: NIRS and aquaphotomics methods invite 100% accuracy, sensitivity, and specificity to detect Paratuberculosis using data mining by unsupervised method, Principal Component Analysis, and supervised methods: Soft Independent Modeling of Class Analogiest, Linear Discriminant Analysis, Quadratic Discriminant Analysis, Partial Least Square-Discriminant Analysis, and Support Vector Machine models. Discussion: The current study found that monitoring blood plasma with NIR spectra provides an opportunity to analyze antibody levels indirectly via changes in water spectral patterns caused by complex physiological changes, such as the amount of antibodies related to Paratuberculosis by aquagram.


Assuntos
Doenças dos Bovinos , Paratuberculose , Espectroscopia de Luz Próxima ao Infravermelho , Animais , Bovinos , Paratuberculose/diagnóstico , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Doenças dos Bovinos/diagnóstico , Doenças dos Bovinos/sangue , Sensibilidade e Especificidade , Mycobacterium avium subsp. paratuberculosis/imunologia , Mycobacterium avium subsp. paratuberculosis/isolamento & purificação , Mycobacterium avium subsp. paratuberculosis/genética , Feminino , Indústria de Laticínios , Ensaio de Imunoadsorção Enzimática/métodos
12.
Sci Rep ; 14(1): 14154, 2024 06 19.
Artigo em Inglês | MEDLINE | ID: mdl-38898088

RESUMO

Earlier access to patients' biomarker status could transform disease management. However, gold-standard techniques such as enzyme-linked immunosorbent assays (ELISAs) are typically not deployed at the point-of-care due to their cumbersome instrumentation and complexity. Electrochemical immunosensors can be disruptive in this sector with their small size and lower cost but, without further modifications, the performance of these sensors in complex media (e.g., blood) has been limited. This paper presents a low-cost fluidic accessory fabricated using widely accessible materials and processes for boosting sensor sensitivity through confinement of the detection media next to the electrode surface. Liquid confinement first highlighted a spontaneous reaction between the pseudoreference electrode and ELISA detection substrate 3,3',5,5'-tetramethylbenzidine (TMB) that decreases the amount of oxTMB available for detection. Different strategies are investigated to limit this and maximize reliability. Next, flow cell integration during the signal amplification step of sensor preparation was shown to substantially enhance the detection of cytokine interleukin-6 (IL-6) with the best sensitivity boost recorded for fresh human plasma (x7 increase compared to x5.8 in purified serum and x5.5 in PBS). The flow cell requires no specialized equipment and can be seamlessly integrated with commercial sensors, making an ideal companion for electrochemical signal enhancement.


Assuntos
Técnicas Eletroquímicas , Humanos , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Imunoensaio/métodos , Imunoensaio/instrumentação , Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/instrumentação , Eletrodos , Ensaio de Imunoadsorção Enzimática/métodos , Interleucina-6/sangue , Interleucina-6/análise , Benzidinas/química
13.
Methods Mol Biol ; 2822: 175-186, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38907919

RESUMO

Oligonucleotide probe tagging and reverse transcriptase polymerase-chain reaction (RT-PCR) are the most widely used techniques currently used for detecting and analyzing RNA. RNA detection using labeled oligonucleotide probe-based approaches is suitable for point-of-care (POC) applications but lacks assay sensitivity, whereas RT-PCR requires complex instrumentation. As an alternative, immunoassay detection formats coupled with isothermal RNA amplification techniques have been proposed for handheld assay development. In this chapter, we describe a robust technique comprising of: (a) target RNA tagging with a complementary oligonucleotide probe labeled with a hapten moiety to form a DNA/RNA duplex hybrid; (b) complexing the DNA/RNA duplex with a pre-coated antibody (Ab) directed at the hapten moiety; (c) sandwich complex formation with an Ab that selectively recognizes the DNA/RNA structural motif; and (d) detection of the sandwich complex using a secondary Ab enzyme conjugate targeting the anti-DNA/RNA Ab followed by standard enzyme-linked immunosorbent assay (ELISA) visualization.


Assuntos
Ensaio de Imunoadsorção Enzimática , RNA , RNA/análise , RNA/genética , Ensaio de Imunoadsorção Enzimática/métodos , Humanos , Imunoensaio/métodos , Sondas de Oligonucleotídeos/química , Sondas de Oligonucleotídeos/genética , Anticorpos/imunologia , Hibridização de Ácido Nucleico/métodos , DNA/análise
14.
Med Microbiol Immunol ; 213(1): 10, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38907945

RESUMO

Rapid tests allow outpatient, low cost, reliable, screening for chronic HIV infection. However, data regarding their sensitivity on primary infection remain scarce. The objective of this study was to assess sensitivity of nine HIV rapid tests for primary HIV-1 infection screening. Seventy-five serum samples from patients during HIV-1 primary infection were included. Primary infection was diagnosed by a positive 4th generation ELISA and HIV-1 RNA positivity confirmed by Western blot patterns associated with HIV-1 primary infection. Early seroconversion was defined as the absence of antibodies on HIV-1 Western blot associated with HIV-1 RNA and p24-antigen positivity. An identical sensitivity (95% CI) of 76.7% (65.2-84.2%) was observed for HIV 1/2 STAT-PAK® Assay (STAT-PAK), INSTI™ HIV-1/HIV-2 antibody Test (INSTI), SURE CHECK® HIV 1/2 (SURE CHECK) and MULTISURE HIV rapid test (MULTISURE) with visual reading. Sensitivity was 74.7% (63.8-83.1%) for MULTISURE (automatic reading), 77.0% (66.3-85.1%) for FIRST RESPONSE® Test VIH 1-2.O CARTE (FIRST RESPONSE), 83.8% (73.8-90.5%) for VIKIA HIV1/2® (VIKIA), 88.0% (78.7-93.6%) for Genie™ Fast HIV 1/2 (Genie Fast), 88.6% (79.0-94.1%) for Hexagon HIV (Hexagon), and 92.8% (83.6-96.3%) for Exacto® TEST HIV Pro (Exacto). However, rapid tests performed poorly for the early seroconversion subgroup (n = 14), with sensitivities ranging from 7% (1.3-31.5%) for STAT-PAK, INSTI, SURE CHECK, MULTISURE (automatic reading), to 29% (12-55%) for FIRST RESPONSE, 31% (13-58%) for VIKIA, 43% (21-67%) for Hexagon and 57.1% (32.6-78.6%) for Exacto and Genie Fast. Overall, despite significant discrepancies in sensitivity, HIV rapid tests should be used with caution in the context of a suspected primary infection.


Assuntos
Anticorpos Anti-HIV , Infecções por HIV , HIV-1 , Programas de Rastreamento , Sensibilidade e Especificidade , Humanos , Infecções por HIV/diagnóstico , HIV-1/imunologia , HIV-1/isolamento & purificação , Masculino , Programas de Rastreamento/métodos , Feminino , Adulto , Anticorpos Anti-HIV/sangue , Pessoa de Meia-Idade , RNA Viral/sangue , Ensaio de Imunoadsorção Enzimática/métodos , Adulto Jovem , Western Blotting/métodos , Testes Diagnósticos de Rotina/métodos , Teste de HIV/métodos
15.
Appl Microbiol Biotechnol ; 108(1): 355, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38822832

RESUMO

Getah virus (GETV) is a re-emerging mosquito-borne alphavirus that is highly pathogenic, mainly to pigs and horses. There are no vaccines or treatments available for GETV in swine in China. Therefore, the development of a simple, rapid, specific, and sensitive serological assay for GETV antibodies is essential for the prevention and control of GETV. Current antibody monitoring methods are time-consuming, expensive, and dependent on specialized instrumentation, and these features are not conducive to rapid detection in clinical samples. To address these problem, we developed immunochromatographic test strips (ICTS) using eukaryotically expressed soluble recombinant p62-E1 protein of GETV as a labelled antigen, which has good detection sensitivity and no cross-reactivity with other common porcine virus-positive sera. The ICTS is highly compatible with IFA and ELISA and can be stored for 1 month at 37 °C and for at least 3 months at room temperature. Hence, p62-E1-based ICTS is a rapid, accurate, and convenient method for rapid on-site detection of GETV antibodies. KEY POINTS: • We established a rapid antibody detection method that can monitor GETV infection • We developed colloidal gold test strips with high sensitivity and specificity • The development of colloidal gold test strips will aid in the field serologic detection of GETV.


Assuntos
Alphavirus , Anticorpos Antivirais , Coloide de Ouro , Sensibilidade e Especificidade , Animais , Coloide de Ouro/química , Anticorpos Antivirais/sangue , Anticorpos Antivirais/imunologia , Alphavirus/imunologia , Suínos , Cromatografia de Afinidade/métodos , Infecções por Alphavirus/diagnóstico , Infecções por Alphavirus/imunologia , Doenças dos Suínos/diagnóstico , Doenças dos Suínos/virologia , Fitas Reagentes , China , Ensaio de Imunoadsorção Enzimática/métodos
16.
PLoS One ; 19(6): e0303393, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38843247

RESUMO

INTRODUCTION: Viral Load (VL) monitoring is a crucial component of patient care during antiretroviral therapy (ART) but is not routinely available in many resource-constrained settings, where millions of patients will require care for decades to come. We hypothesise a serologic 'recent infection' test (Sedia LAg assay) which has a high dynamic range for detecting antigen-driven antibody response can provide informative proxies for VL trajectories. METHODS: A retrospective study where we analysed data linked via specimens in a well-described repository for recent infection test benchmarking (CEPHIA collaboration). Patient panels were comprised of 1) observations straddling ART start; 2) observations from a period of stable viral suppression; 3) observations straddling rebound after a period of viral suppression. We analysed an individual's Sedia LAg ELISA normalised optical density (ODn) trends within these categories. Using groups 2) and 3) we evaluated the specificity and sensitivity of a proposed proxy for "the latest observation is at a time of VL rebound"; proxy was defined as follows: we estimated patient-specific mean-previous-ODn for all observations with at least two preceding virally suppressed observations. We considered various thresholds to define both "VL suppression" and "ODn uptick". RESULTS: In regression analysis by category: 1) ODn gradients are statistically significantly negative just after ART-start (p = 0.010); 2) During periods of stable viral suppression, ODn tended to decline, but not statistically significantly, for a range of clinically meaningful "VL suppression" thresholds; 3) comparing ODn values just before, versus at, "VL rebound", ODn changes were statistically significantly increasing at rebound (p = 0.001). In the analysis comparing groups 2) and 3), at a Z score threshold of 0.8, the proposed proxy for a first viral rebound had an observed specificity and sensitivity both close to 90%. CONCLUSION: The high dynamic range of serological tests previously investigated for defining 'recent infection' has potential, as demonstrated using the Sedia LAg ELISA, to provide meaningful information about the success of ART, during treatment initiation, at times of stable suppression, and to flag possible viral rebound. It should be investigated how this can be combined with patient management workflows and (clinical and) other data, to provide efficiencies in long-term monitoring viral control in resource-limited settings.


Assuntos
Infecções por HIV , Carga Viral , Humanos , Infecções por HIV/tratamento farmacológico , Infecções por HIV/imunologia , Infecções por HIV/virologia , Estudos Retrospectivos , Masculino , Feminino , Adulto , Ensaio de Imunoadsorção Enzimática/métodos , Sensibilidade e Especificidade , Pessoa de Meia-Idade , Antirretrovirais/uso terapêutico , HIV-1/imunologia
17.
PLoS One ; 19(6): e0304268, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38838004

RESUMO

American tegumentary leishmaniasis (ATL) diagnosis is an open question, and the search for a solution is urgent. The available tests that detect the etiological agent of the infection are specific for ATL diagnosis. However, they present disadvantages, such as low sensitivity and the need for invasive procedures to obtain the samples. Immunological methods (leishmanin skin test and search for anti-Leishmania antibodies) are good alternatives to the etiological diagnosis of ATL. Presently, we face problems with disease confirmation due to the discontinuity in the production of leishmanin skin test antigen, particularly in resource-poor settings. Aiming to diagnose ATL, we validated rLb6H-ELISA for IgG antibodies using 1,091 samples from leishmaniasis patients and healthy controls, divided into four panels, living in 19 Brazilian endemic and non-endemic states. The rLb6H-ELISA showed a sensitivity of 98.6% and a specificity of 100.0%, with the reference panel comprising 70 ATL patient samples and 70 healthy controls. The reproducibility evaluation showed a coefficient of variation of positive samples ≤ 8.20% for repeatability, ≤ 17,97% for reproducibility, and ≤ 8.12% for homogeneity. The plates sensitized with rLb6H were stable at 4°C and -20°C for 180 days and 37°C for seven days, indicating 12 months of validity. In samples of ATL patients from five research and healthcare centers in endemic and non-endemic areas, rLb6H-ELISA showed a sensitivity of 84.0%; no significant statistical difference was observed among the five centers (chi-square test, p = 0.13). In samples of healthy controls from four areas with different endemicity, a specificity of 92.4% was obtained; lower specificity was obtained in a visceral leishmaniasis high endemicity locality (chi-square test, p<0.001). Cross-reactivity was assessed in 166 other disease samples with a positivity of 13.9%. Based on the good diagnostic performance and the reproducibility and stability of the antigen, we suggest using ELISA-rLb6H to diagnose ATL.


Assuntos
Antígenos de Protozoários , Ensaio de Imunoadsorção Enzimática , Leishmaniose Cutânea , Humanos , Leishmaniose Cutânea/diagnóstico , Leishmaniose Cutânea/imunologia , Leishmaniose Cutânea/parasitologia , Leishmaniose Cutânea/epidemiologia , Ensaio de Imunoadsorção Enzimática/métodos , Antígenos de Protozoários/imunologia , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Adolescente , Reprodutibilidade dos Testes , Proteínas Recombinantes/imunologia , Adulto Jovem , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Anticorpos Antiprotozoários/sangue , Anticorpos Antiprotozoários/imunologia , Idoso , Criança , Estudos de Casos e Controles , Brasil/epidemiologia
18.
Biotechnol J ; 19(6): e2400074, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38896409

RESUMO

The ELISA is the most worldwide method for immunoassay. However, the ELISA is losing ground due to low reproducibility of manual experimental processes in both R&D and IVD areas. An automated platform is a good solution, but there are still limitations owning to extremely high cost and requiring large space to set up especially for a small size laboratory. Here, we present a novel all-in-one platform called "VEUS" settable on the laboratory table that offers comprehensive automation of the entire multiplex immunoassay process by exploiting antibody conjugated magnetic particles, quality control and then immunoanalytical reaction, thereby enhancing detection sensitivity and high reproducibility. As a proof of concept, the system exhibits a sensitive LOD of 0.6 and 3.1 pg mL-1 within 1 h run, comparable precision that of molecular diagnostic systems based on PCR method, enabling rapid multiplex diagnosis of Influenza A, Influenza B, and COVID-19 viruses with similar symptoms. Through automation by the all-in-one system, it can be used by novice users, something innovative for immunoassays, relying heavily on user experience. Furthermore, it can contribute to streamline entire immunoassay processes of diverse biomarkers with high reproducibility and convenience in laboratories.


Assuntos
SARS-CoV-2 , Humanos , Imunoensaio/métodos , SARS-CoV-2/imunologia , SARS-CoV-2/isolamento & purificação , Anticorpos Imobilizados/imunologia , Anticorpos Imobilizados/química , Reprodutibilidade dos Testes , COVID-19/diagnóstico , COVID-19/virologia , Ensaio de Imunoadsorção Enzimática/métodos , Vírus da Influenza A/imunologia , Vírus da Influenza B/imunologia , Automação Laboratorial/métodos , Limite de Detecção
19.
Clin Exp Dent Res ; 10(3): e883, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38853451

RESUMO

OBJECTIVE: The objective of this study was to investigate the effectiveness of testing for active matrix metalloproteinase-8 (aMMP-8) by a quantitative point-of-care (PoC), chairside lateral flow immunotest and azurocidin, in the peri-implant sulcular fluid (PISF), as biomarkers for the presence or absence of peri-implant diseases. BACKGROUND: Current research indicates that proinflammatory cytokines and extracellular matrix-degrading enzymes may be of value to diagnose and predict peri-implant disease initiation and progression, but more data are needed. METHODS: Eighty patients with implants were recruited. PISF samples were collected and quantitatively analyzed for aMMP-8 (chairside) and azurocidin with ELISA. Radiographic assessments and clinical indices (probing depth, probing attachment level, bleeding on probing, and plaque) were recorded after sampling. Kruskal-Wallis test and pairwise post hoc Dunn-Bonferroni test were used to relate aMMP-8 levels and azurocidin levels to clinical parameters. The diagnostic ability of aMMP-8 (ng/mL) and azurocidin was analyzed by receiver operator curve analysis. Area under the curve (AUC) was calculated and the Spearman's rho, and the coefficient of determination (R2) were used to calculate the correlations between aMMP-8, azurocidin, and periodontal parameters. RESULTS: Statistically significant differences were observed for aMMP-8 levels but not for azurocidin between healthy implants, implants with mucositis, and those with peri-implantitis (13.65 ± 7.18, 32.33 ± 21.20, and 73.07 ± 43.93 ng/mL, respectively), (Kruskall-Wallis test p < .05). The aMMP-8 test with a threshold of 20 ng/mL has a sensitivity of 71.7% and a specificity of 77.8% to identify peri-implantitis and healthy implants, respectively. AUC was found to be 0.814, and the accuracy of the method reaches 73.8%. Above a cutoff value of 33.7 ng/mL of aMMP-8, the accuracy of the test to detect peri-implantitis reaches 77.5% in relation to 62.5% of BoP from the same site. CONCLUSION: Taken collectively, present data indicate that the aMMP-8 PoC lateral flow immunotest can be a beneficial, adjunctive diagnostic quantitative tool for real-time screening for peri-implant diseases.


Assuntos
Biomarcadores , Implantes Dentários , Líquido do Sulco Gengival , Metaloproteinase 8 da Matriz , Peri-Implantite , Humanos , Metaloproteinase 8 da Matriz/análise , Metaloproteinase 8 da Matriz/metabolismo , Biomarcadores/análise , Biomarcadores/metabolismo , Masculino , Feminino , Pessoa de Meia-Idade , Peri-Implantite/diagnóstico , Peri-Implantite/metabolismo , Idoso , Implantes Dentários/efeitos adversos , Líquido do Sulco Gengival/química , Líquido do Sulco Gengival/metabolismo , Adulto , Ensaio de Imunoadsorção Enzimática/métodos , Índice Periodontal , Curva ROC , Proteínas Sanguíneas , Peptídeos Catiônicos Antimicrobianos
20.
Anal Chem ; 96(24): 10064-10073, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38842443

RESUMO

The global spread of monkeypox has become a worldwide public healthcare issue. Therefore, there is an urgent need for accurate and sensitive detection methods to effectively control its spreading. Herein, we screened by phage display two peptides M4 (sequence: DPCGERICSIAL) and M6 (sequence: SCSSFLCSLKVG) with good affinity and specificity to monkeypox virus (MPXV) B21R protein. To simulate the state of the peptide in the phage and to avoid spatial obstacles of the peptide, GGGSK was added at the C terminus of M4 and named as M4a. Molecular docking shows that peptide M4a and peptide M6 are bound to different epitopes of B21R by hydrogen bonds and salt-bridge interactions, respectively. Then, peptide M4a was selected as the capture probe, phage M6 as the detection probe, and carbonized polymer dots (CPDs) as the fluorescent probe, and a colorimetric and fluorescent double-signal capture peptide/antigen/signal peptide-displayed phage sandwich ELISA triggered by horseradish peroxidase (HRP) through a simple internal filtration effect (IFE) was constructed. HRP catalyzes H2O2 to oxidize 3,3',5,5'-tetramethylbenzidine (TMB) to generate blue oxidized TMB, which can further quench the fluorescence of CPDs through IFE, enabling to detect MPXV B21R in colorimetric and fluorescent modes. The proposed simple immunoassay platform shows good sensitivity and reliability in MPXV B21R detection. The limit of detection for colorimetric and fluorescent modes was 27.8 and 9.14 pg/mL MPXV B21R, respectively. Thus, the established double-peptide sandwich-based dual-signal immunoassay provides guidance for the development of reliable and sensitive antigen detection capable of mutual confirmation, which also has great potential for exploring various analytical strategies for other respiratory virus surveillance.


Assuntos
Ensaio de Imunoadsorção Enzimática , Peptídeos , Ensaio de Imunoadsorção Enzimática/métodos , Peptídeos/química , Antígenos Virais/imunologia , Antígenos Virais/análise , Antígenos Virais/química , Simulação de Acoplamento Molecular , Peroxidase do Rábano Silvestre/química , Peroxidase do Rábano Silvestre/metabolismo , Limite de Detecção , Corantes Fluorescentes/química , Biblioteca de Peptídeos , Benzidinas/química , Colorimetria/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...