Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 9.330
Filtrar
1.
J. optom. (Internet) ; 17(3): [100508], jul.-sept2024. tab, graf
Artigo em Inglês | IBECS | ID: ibc-231874

RESUMO

Purpose: To report the visual and refractive characteristics and the prevalence of amblyopia in patients with different types of Duane's Retraction Syndrome (DRS). Method: This retrospective study was performed on hospital records of 582 DRS patients at Farabi Hospital, Iran, from 2012 to March 2022. Results: The mean age of patients was 19.4 ± 11.9 (range, 3–70) years [335 (57.6 %) females and 247 (42.4 %) males (P < .001)]. DRS type I, II, III, and IV were presented in 347 (59.6 %), 148 (25.4 %), 82 (14.1 %), and 5 (0.9 %) patients, respectively. There were 530 (91.1 %) patients with unilateral and 52 (8.9 %) with bilateral involvement. In the unilateral patients, the DRS eyes' corrected distance visual acuity (CDVA) and astigmatism were significantly worse than the Non-DRS Eyes (P < .001). The mean amount of all refractive and visual parameters in bilateral patients' right or left eyes was significantly lower than in unilateral patients' non-DRS eyes (all P < .05). Anisometropia was observed in 75(12.9 %) of the patients. Amblyopia was observed in 18.5 % (98 patients) and 36.5 % (19 patients) of unilateral and bilateral DRS patients, respectively (P < .001). In unilateral patients, amblyopia was found in 57 (16.4 %) patients with Type I, 22 (14.9 %) patients with Type II, 16 (19.5 %) patients with Type III, and 3 (60 %) patients with Type IV. Forty-four (37.6 %) of patients with amblyopia had anisometropia. Conclusion: This large-scale study indicates that DRS types differ in terms of refractive error, visual acuity, and the prevalence of amblyopia and anisometropia. Clinicians should be aware of the clinical features associated with different types of DRS.(AU)


Assuntos
Humanos , Masculino , Feminino , Visão Ocular , Ambliopia , Síndrome da Retração Ocular , Erros de Refração , Anisometropia
2.
J. optom. (Internet) ; 17(3): [100512], jul.-sept2024. graf, tab
Artigo em Inglês | IBECS | ID: ibc-231875

RESUMO

Purpose: In children under 20 years, refractive development targets a cycloplegic refractive error of +0.5 to +1.5D, while presbyopes over 40 years generally have non-cycloplegic errors of ≥ +1D. Some papers suggest these periods are separated by a period of myopic refractive error (i.e., ≤ –0.50D), but this remains unclear. Hence, this work investigates the mean cycloplegic refractive error in adults aged between 20 – 40 years. Methods: In 2002 a cross-sectional study with stratified cluster sampling was performed on the population of Tehran, providing cycloplegic and non-cycloplegic refractive error data for the right eyes of 3,576 participants, aged 30.6 ± 18.6 years (range: 1–86 years). After grouping these data into age groups of 5 years, the refractive error histogram of each group was fitted to a Bigaussian function. The mean of the central, emmetropized peak was used to estimate the mean refractive error without the influence of myopia. Results: The mean cycloplegic refractive error at the emmetropized peak decreased from +1.10 ± 0.11D (95 % confidence interval) to +0.50 ± 0.04D before 20 years and remains stable at that value until the age of 50 years. The non-cycloplegic refractive error also sees a stable phase at 0.00 ± 0.04D between 15 – 45 years. After 45 – 50 years both cycloplegic and non-cycloplegic refractive error become more hypermetropic over time, +1.14 ± 0.12D at 75 years. Conclusions: The cycloplegic refractive error in adults is about +0.50D between 20 – 50 years, disproving the existence of the myopic period at those ages.(AU)


Assuntos
Humanos , Masculino , Feminino , Adulto , Visão Ocular , Testes Visuais , Erros de Refração , Emetropia , Estudos Transversais , Irã (Geográfico)
4.
BMC Ophthalmol ; 24(1): 207, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38711043

RESUMO

PURPOSE: To understand the ocular biometric parameters characteristics and refractive errors in 3-to 6-year-old preschool children in Chengdu, China, and to investigate the prevalence of refractive errors. METHOD: A school-based cross-sectional study was conducted in Chengdu from 2020 to2022 with a total of 666 kindergartens. All children were measured by non-cycloplegic autorefraction and uncorrected visual acuity (UCVA) and ocular biometric parameters. Finally, univariate linear regression models were used to analyze the relationship between ocular biometric parameters and refraction. RESULTS: A total of 108,578 preschool children aged 3-6 underwent examinations, revealing a myopia prevalence of 6.1%. The mean axial length (AL), keratometry (K), corneal radius (CR), axial length/corneal radius (AL/CR) Ratio, central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), and vitreous chamber depth (VCD) were 22.35 ± 0.69 mm, 43.35 ± 1.58 D, 7.80 ± 0.28 mm, 2.87 ± 0.08, 533.31 ± 32.51 µm, 2.70 ± 0.28 mm, 3.91 ± 0.27 mm, and 15.20 ± 0.68 mm, respectively. With increasing age, AL, CR, AL/CR ratio, CCT, ACD, LT, and VCD also increased. Regardless of age, males consistently exhibited longer AL, flatter corneal curvature, shallower ACD, thicker CCT, thinner LT, and longer VCD compared to females. AL, K, CR, LT, and VCD all showed significant linear relationships with SE (all P < 0.001) in univariate linear regression analysis after adjusting for gender and age. CONCLUSION: The prevalence of myopia among preschool children aged 3-6 in Chengdu is relatively low. Ocular biometric parameters affecting refractive errors include AL, K, CR, LT, and VCD. The preschool period serves as a critical phase for myopia prevention and control.


Assuntos
Biometria , Refração Ocular , Acuidade Visual , Humanos , Feminino , Masculino , Estudos Transversais , China/epidemiologia , Refração Ocular/fisiologia , Pré-Escolar , Criança , Acuidade Visual/fisiologia , Prevalência , Comprimento Axial do Olho , Córnea/patologia , Córnea/anatomia & histologia , Erros de Refração/epidemiologia , Erros de Refração/fisiopatologia , Câmara Anterior/diagnóstico por imagem , Câmara Anterior/patologia , Miopia/epidemiologia , Miopia/fisiopatologia
5.
PLoS One ; 19(5): e0303324, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38739623

RESUMO

BACKGROUND: Scoliosis is one of the most common surgical disorders of the pediatric spine. Refractive errors are commonly associated with vision impairment worldwide. However, it is currently unclear whether refractive error correlates directly with the development of scoliosis. METHODS: A cross-sectional study was performed in 2023, and a stratified cluster sampling technique was employed among school-aged students in Nantong City, China. Univariate and multivariate logistic regression analyses were used to investigate specific correlations between scoliosis and related parameters; various types of refractive errors were also included in the study. RESULTS: The prevalence of scoliosis among school-aged students was 2.2% in Nantong city. Multiple logistic regression analyses showed that myopia, hyperopia, astigmatism, and anisometropia were not correlated with the development of scoliosis (all, p≥0.05). Lower body mass index (BMI) [adjusted odds ratio (aOR) = 0.92; 95% confidence interval (CI): 0.88-0.95; p<0.001], living in rural areas (aOR = 1.40; 95% CI: 1.05-1.86; p = 0.020), and older age (aOR = 1.32; 95% CI: 1.25-1.38; p<0.001) had significantly higher risks of scoliosis. CONCLUSIONS: Refractive errors did not correlate with the development of scoliosis. However, BMI, living in rural areas and older age did correlate with the development of scoliosis.


Assuntos
Erros de Refração , Escoliose , Escoliose/epidemiologia , Escoliose/complicações , Humanos , Masculino , Feminino , Estudos Transversais , Erros de Refração/epidemiologia , Criança , Adolescente , China/epidemiologia , Prevalência , Fatores de Risco , Índice de Massa Corporal , Modelos Logísticos
6.
Int Ophthalmol ; 44(1): 185, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38634955

RESUMO

PURPOSE: The aim of the study was to analyze the time-savings associated with introduction of Streamlight™ (Alcon Laboratories, Fort Worth, TX, USA) transepithelial photorefractive keratectomy (PRK) in surface corneal ablations. METHODS: All refractive surgeries were performed using the Alcon WaveLight® EX500 at the ArtLife Clinic, Gdansk, Poland. The study included patients treated for refractive errors with transepithelial PRK between April 2019 and October 2021, who were matched with patients treated with alcohol-assisted PRK during the same period. Only results for the left eye were analyzed. RESULTS: One-hundred-five patients underwent transepithelial PRK (age 33.42 ± 8.67 years) and were matched with 105 patients that underwent alcohol-assisted PRK (age 33.05 ± 10.16 years; p = 0.11). The mean preoperative spherical equivalent refraction was - 2.04 ± 2.28 D, and - 1.9 ± 1.71 D for the transepithelial and alcohol-assisted PRK group, respectively (p = 0.20). The total surgery time was non-significantly shorter in transepithelial PRK (349.46 ± 47.83 s) than in alcohol-assisted PRK (354.93 ± 137.63 s; p = 0.7); however, the variance of surgical time was significantly lower in transepithelial PRK (p < 0.001). The laser treatment duration was greater in transepithelial PRK (41.78 ± 17.2 s) than in alcohol-assisted PRK (8.48 ± 6.12 s; p < 0.001), and so was the number of breaks during the laser treatment (0.95 ± 0.63 vs. 0.53 ± 0.88, respectively; p < 0.001). CONCLUSION: The introduction of transepithelial PRK did not bring significant time-associated savings into the refractive surgery suite.


Assuntos
Oftalmologia , Ceratectomia Fotorrefrativa , Erros de Refração , Procedimentos Cirúrgicos Refrativos , Humanos , Adulto Jovem , Adulto , Olho , Etanol
7.
BMC Ophthalmol ; 24(1): 161, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38605375

RESUMO

BACKGROUND: Myopia is becoming a huge burden on the world's public health systems. The purpose of this study was to explore the effect of brimonidine in the treatment of form-deprivation myopia (FDM) and the relationship between intraocular pressure (IOP) and myopia development. METHODS: Monocular form deprivation myopia (FDM) was induced in three-week-old pigmented male guinea pigs. They were treated with 3 different methods of brimonidine administration (eye drops, and subconjunctival or intravitreal injections). Four different concentrations of brimonidine were tested for each method (2µg/µL, 4µg/µL, 20µg/µL, and 40µg/µL). All treatments continued for a period of 21 days. Tonometry, retinoscopy, and A-scan ultrasonography were used to monitor intraocular pressure, refractive error and axial length (AL), respectively. RESULTS: Treatment with subconjunctival brimonidine at 40µg/µL, and intravitreal brimonidine at 2µg/µL and 4µg/µL, inhibited the development of FDM. The myopic refraction, excessive axial length, and elevation of IOP were significantly decreased. Brimonidine in eye drops was ineffective. CONCLUSION: Brimonidine at appropriate doses significantly reduced the development of FD myopia in guinea pigs. The IOP may change with FD myopia.


Assuntos
Miopia , Erros de Refração , Masculino , Animais , Cobaias , Tartarato de Brimonidina/uso terapêutico , Miopia/tratamento farmacológico , Refração Ocular , Soluções Oftálmicas , Privação Sensorial , Modelos Animais de Doenças
8.
BMC Ophthalmol ; 24(1): 179, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38641836

RESUMO

BACKGROUND: Plusoptix photoscreeners are capable of measuring refractive errors of children from 1 meter distance, without cyloplegia. We aimed to compare refractive data obtained from the newest version of Plusoptix (model 12) with cycloplegic autorefraction. METHODS: We examined 111 consecutive children aged 3-7 years first by Plusoptix A12C under manifest condition and subsequently for cycloplegic refraction by Topcon KR-1 tabletop autorefractometer. Sphere, spherical equivalent, cylinder and axis of astigmatism measured by the two methods were analyzed to determine correlation, agreement and differences. RESULTS: Binocular examination of 111 children aged 4.86±1.27 years revealed good agreement between refractive data obtained by Plusoptix and cycloautorefraction, according to Bland-Altman plots. Significant (p < 0.001) and strong correlation was found between all refractive measurements (Pearson's r value of 0.707 for sphere, 0.756 for pherical equivalent, and 0.863 for cylinder). Plusoptix mean sphere, spherical equivalent and cylinder were 1.22, 0.56, and -1.32 D, respectively. Corresponding values for cycloautorefraction were 1.63, 1.00, and -1.26 D. The difference between axis of cylinder measured by the two methods was < 10° in 144 eyes (64.9%). CONCLUSIONS: Considering the significant agreement and correlation between Plusoptix photoscreener and cycloplegic autorefraction, the need for cycloplegic drops in refractive examination of children may be obviated. The mean difference between cylinder measurements are considerably trivial (0.06 D), but sphere is approximately 0.4 D underestimated by Plusoptix compared to cycloautorefraction, on average.


Assuntos
Astigmatismo , Erros de Refração , Seleção Visual , Criança , Humanos , Midriáticos , Seleção Visual/métodos , Erros de Refração/diagnóstico , Refração Ocular
9.
Turk J Ophthalmol ; 54(2): 56-62, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38644780

RESUMO

Objectives: Determining the accuracy of cycloplegic refractive error measurements made with the Spot Vision Screener (SVS, Welch Allyn Inc, Skaneateles Falls, NY, USA) is important for refractive assessment of uncooperative patients during optometric examinations. This study compared cycloplegic refractive errors measured by SVS and tabletop autorefractometer to cycloplegic retinoscopy in children. Materials and Methods: Eighty-eight eyes of 44 subjects were examined in the study. Refractive error measurements were obtained under cycloplegia using retinoscopy, SVS, and Nidek ARK-530 tabletop autorefractometer (ARK-530, Nidek, Japan). Spherical and cylindrical values, spherical equivalents (SE), and Jackson cross-cylinder values at axes of 0° (J0) and 45° (J45) were recorded. Correlations between methods were analyzed using intraclass correlation coefficient (ICC) and Bland-Altman analysis. Results: The mean age was 7 years (range: 6 months-17 years). Sixteen (36%) of the subjects were female and 28 (64%) were male. For SE there was excellent agreement between retinoscopy and SVS (ICC: 0.924) and between retinoscopy and tabletop autorefractometer (ICC: 0.995). While there was a moderate correlation between retinoscopy and SVS for cylindrical values (ICC: 0.686), excellent correlation was detected between retinoscopy and autorefractometer (ICC: 0.966). J0 and J45 crosscylinder power values were not correlated between retinoscopy and SVS (ICC: 0.472) or retinoscopy and tabletop autorefractometer (ICC: 0.442). Retinoscopy was correlated with both SVS and tabletop autorefractometer for all parameters within ±1.96 standard deviations in Bland-Altman analysis. Conclusion: Cycloplegic retinoscopy is the gold standard for refractive error measurement in the pediatric population. However, it requires time and experienced professionals. This study revealed moderate to good agreement between SVS and retinoscopy, with better agreement in spherical errors than cylindrical errors. Although the SVS is intended for screening programs, it may also be useful in the pediatric eye office to estimate spherical refractive error in uncooperative patients.


Assuntos
Refração Ocular , Erros de Refração , Retinoscopia , Seleção Visual , Humanos , Feminino , Masculino , Criança , Retinoscopia/métodos , Adolescente , Pré-Escolar , Refração Ocular/fisiologia , Erros de Refração/diagnóstico , Erros de Refração/fisiopatologia , Lactente , Reprodutibilidade dos Testes , Seleção Visual/instrumentação , Seleção Visual/métodos , Midriáticos/administração & dosagem
10.
J Pak Med Assoc ; 74(3): 599-562, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38591297

RESUMO

This observational study aimed to evaluate the use of a single portable device to assess the non-invasive tear break-up time (NITBUT), tear meniscus height (TMH), and lipid layer patterns (LLP) in young females with refractive errors (REs). The study was conducted at the College of Applied Medical Science (Female campus), Riyadh, Saudi Arabia between January 5, 2021 to May 15, 2021. Forty young females, with mean age of 23.0± 4.3 years with REs (-2.53 ± 2.05 D) and 40 females, mean age 23.8± 4.5 years with healthy eyes were recruited. The tests were administered in the following order: Ocular Surface Disease Index (OSDI), followed by NITBUT, TMH, and LLP. Significant differences (via Mann-Whitney U test) were noted in the median ocular surface disease index (OSDI; p˂0.001), NITBUT (p=0.035), TMH (p=0.009), and LLP (p˂0.001) scores between the study and control groups. Females with REs have significantly lower lipid layer, TMH, and NITBUT scores than those with healthy eyes.


Assuntos
Síndromes do Olho Seco , Lacerações , Erros de Refração , Humanos , Feminino , Adolescente , Adulto Jovem , Adulto , Lágrimas , Erros de Refração/diagnóstico , Síndromes do Olho Seco/diagnóstico , Lipídeos
11.
BMC Ophthalmol ; 24(1): 174, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627647

RESUMO

PURPOSE: To evaluate the long-term clinical outcomes of femtosecond thin-flap LASIK (femto-LASIK) for correction of refractive error after penetrating keratoplasty in keratoconus-affected eyes. SETTING: a private ophthalmology clinic. DESIGN: Prospective interventional case series. METHODS: This prospective interventional case series enrolled 22 eyes of 22 patients who underwent femto-LASIK for the management of post-penetrating keratoplasty ametropia. The refractive error, uncorrected (UDVA), and corrected (CDVA) distance visual acuities and vector analysis were reported in short-term and long-term period after surgery. RESULTS: The mean age was 32.7 ± 7.5 years (range, 23 to 47 years) at the surgery time. The average time between PK and femto-LASIK was 42.5 ± 31.7 months. The average follow-up duration after femto-LASIK was 81.2 ± 18.6 months. The mean preoperative UDVA significantly improved from 0.47 ± 0.15 logMAR to 0.35 ± 0.14 logMAR at 12 months (P = 0.048) and 0.4 ± 0.17 at final follow-up exam (P = 0.007). CDVA was 0.22 ± 0.1 at baseline which improved to 0.18 ± 0.15 and 0.15 ± 0.1 logMAR at 12 and 81 months, respectively. (Ps = 0.027, 0.014). The mean cylinder before surgery was - 5.04 ± 1.4D which significantly decreased to -1.5 ± 0.8 D at 12 months postoperatively. (P < 0.001). There was a significant increase in refractive astigmatism from 12 months to 81 months postoperatively (-3.1 ± 2.0, P = 0.002). At the final visit, the efficacy index was 0.83, and the safety index was 1.16. CONCLUSIONS: Despite the short-term outcome indicated that femo-LASIK was effective for correction of post-keratoplasty ametropia during short-term period, a notable regression in its effect was observed in the long-term follow-up. Therefore, the predictability of this technique might decrease in the long-term.


Assuntos
Astigmatismo , Ceratomileuse Assistida por Excimer Laser In Situ , Erros de Refração , Humanos , Adulto , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Ceratoplastia Penetrante/efeitos adversos , Estudos Prospectivos , Astigmatismo/etiologia , Astigmatismo/cirurgia , Refração Ocular , Lasers , Resultado do Tratamento , Lasers de Excimer/uso terapêutico
12.
Zhonghua Yan Ke Za Zhi ; 60(4): 384-391, 2024 Apr 11.
Artigo em Chinês | MEDLINE | ID: mdl-38583063

RESUMO

In order to decelerate the growth of myopia in children and adolescents and reduce the risks of associated eye complications, extensive research has been conducted on preventive measures, including optical, behavioral, and pharmaceutical interventions. Spectacle lenses, due to their safety, convenience, and high patient compliance, stand out as the most common method for correcting refractive errors compared to other interventions. As far as we know, various forms of spectacle lenses are currently used in clinical practice, including bifocal lenses, progressive multifocal lenses, peripheral defocus lenses, defocus incorporated multiple segments (DIMS) lenses, highly aspherical lenslets, diffusion optics technology lenses, and violet light transmission (VL) glasses. However, a systematic and comprehensive overview of myopia-controlling spectacle lenses is still lacking. Therefore, this article summarizes the latest research progress on the myopia prevention and control technology of spectacle lenses at home and abroad, providing theoretical support for the myopia prevention and control effect of different spectacle lens technologies, promoting the application of related technologies in clinical work, and offering new ideas for myopia prevention and control.


Assuntos
Óculos , Miopia , Adolescente , Criança , Humanos , Miopia/prevenção & controle , Refração Ocular , Erros de Refração
13.
Transl Vis Sci Technol ; 13(4): 16, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38591944

RESUMO

Purpose: Myopic marmosets are known to exhibit significant inner retinal thinning compared to age-matched controls. The purpose of this study was to assess inner retinal activity in marmosets with lens-induced myopia compared to age-matched controls and evaluate its relationship with induced changes in refractive state and eye growth. Methods: Cycloplegic refractive error (Rx), vitreous chamber depth (VCD), and photopic full-field electroretinogram were measured in 14 marmosets treated binocularly with negative contact lenses compared to 9 untreated controls at different stages throughout the experimental period (from 74 to 369 days of age). The implicit times of the a-, b-, d-, and photopic negative response (PhNR) waves, as well as the saturated amplitude (Vmax), semi-saturation constant (K), and slope (n) estimated from intensity-response functions fitted with Naka-Rushton equations were analyzed. Results: Compared to controls, treated marmosets exhibited attenuated b-, d-, and PhNR waves Vmax amplitudes 7 to 14 days into treatment before compensatory changes in refraction and eye growth occurred. At later time points, when treated marmosets had developed axial myopia, the amplitudes and implicit times of the b-, d-, and PhNR waves were similar between groups. In controls, the PhNR wave saturated amplitude increased as the b + d-wave Vmax increased. This trend was absent in treated marmosets. Conclusions: Marmosets induced with negative defocus exhibit early alterations in inner retinal saturated amplitudes compared to controls, prior to the development of compensatory myopia. These early ERG changes are independent of refraction and eye size and may reflect early changes in bipolar, ganglion, amacrine, or glial cell physiology prior to myopia development. Translational Relevance: The early changes in retinal function identified in the negative lens-treated marmosets may serve as clinical biomarkers to help identify children at risk of developing myopia.


Assuntos
Miopia , Erros de Refração , Criança , Animais , Humanos , Callithrix , Neuroglia , Miopia/etiologia , Retina
14.
Invest Ophthalmol Vis Sci ; 65(4): 22, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38597724

RESUMO

Purpose: Studies report conflicting findings regarding choroidal thickness changes in response to myopic defocus in humans. This study aimed to investigate the choroidal response to myopic defocus in children and adults using automated analysis. Methods: Participants (N = 46) were distance-corrected in both eyes and viewed a movie on a screen for 10 minutes. Two optical coherence tomography (OCT) radial scans were collected for each eye, then +3 diopters was added to one eye. Participants continued to watch the movie, OCT scans were repeated every 10 minutes for 50 minutes, and then recovery was assessed at 60 and 70 minutes. Defocus was interrupted for approximately two out of each 10 minutes for OCT imaging. OCT images were analyzed using an automated algorithm and trained neural network implemented in MATLAB to determine choroidal thickness at each time point. Repeated-measures ANOVA was used to assess changes with time in three age groups (6-17, 18-30, and 31-45 years) and by refractive error group (myopic and nonmyopic). Results: Choroidal thickness was significantly associated with spherical equivalent refraction, with the myopic group having a thinner choroid than the nonmyopic group (P < 0.001). With imposed myopic defocus, there were no significant changes in choroidal thickness at any time point for any age group and for either refractive error group (P > 0.05 for all). Conclusions: Findings demonstrate that, using the described protocol, the choroidal thickness of children and adults does not significantly change in response to short-term, full-field myopic defocus, in contrast to several previously published studies.


Assuntos
Miopia , Erros de Refração , Adulto , Criança , Humanos , Miopia/diagnóstico , Corioide , Refração Ocular , Tomografia de Coerência Óptica
15.
Zhonghua Yan Ke Za Zhi ; 60(4): 316-321, 2024 Apr 11.
Artigo em Chinês | MEDLINE | ID: mdl-38583054

RESUMO

The International Myopia Institute introduced the concept of "pre-myopia" in 2019, defining it as children with refractive error ≤+0.75 D and >-0.50 D. By considering baseline refractive error, age, and other quantifiable risk factors, there is a significant likelihood that individuals falling into this category may develop myopia in the future. Therefore, it is deemed worthwhile to implement preventative intervention measures.This article delves into the epidemiology of premyopia in children and adolescents, the criteria for determining pre-myopia, the characteristics of refractive changes, and the existing evidence gaps in pre-myopia control technology. Furthermore, it explores the role and advantages of implementing pre-myopia control to enhance efforts in preventing and managing myopia. The paper highlights the essential value and future trajectory of pre-myopia control in the comprehensive management of myopia. The ultimate goal is to foster collaboration with professionals, aiming to discuss innovative strategies for effectively preventing and managing the onset and progression of myopia.


Assuntos
Miopia , Erros de Refração , Criança , Adolescente , Humanos , Miopia/prevenção & controle , Miopia/epidemiologia , Refração Ocular , Testes Visuais , Fatores de Risco
16.
Eye (Lond) ; 38(Suppl 1): 15-20, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38580742

RESUMO

PURPOSE: To evaluate the tolerance to refractive errors of a new purely refractive extended depth of focus (EDF) intraocular lens (IOL) using preclinical and clinical metrics. METHODS: Preclinical evaluation included computer simulations of visual acuity (sVA) and dysphotopsia profile of different IOL designs (refractive EDF, diffractive EDF, multifocal, standard, and enhanced monofocals) using an appropriate eye model with and without ±0.50 D defocus and/or +0.75 D of astigmatism. Patients bilaterally implanted with a refractive EDF (Model ZEN00V) or an enhanced monofocal (Model ICB00) IOL from a prospective, randomized study were included. At the 6-month postoperative visit, uncorrected and corrected distance vision (UDVA and CDVA), visual symptoms, satisfaction and dependency on glasses were evaluated in a subgroup of patients with absolute residual refractive error of >0.25 D in one or both eyes. RESULTS: In the presence of defocus and astigmatism, sVA was comparable for all except the multifocal IOL design. The refractive EDF was more tolerant to myopic outcomes and maintained a monofocal-like dysphotopsia profile with defocus. Binocular logMAR UDVA was -0.03 ± 0.08 for ZEN00V and -0.02 ± 0.11 for ICB00. 100% ZEN00V and 97% ICB00 patients did not need glasses and were satisfied with their distance vision. Monocular CDVA, contrast sensitivity and visual symptoms were also similar between both groups. CONCLUSIONS: The clinical outcomes of the refractive EDF IOL demonstrated high quality distance vision and dysphotopsia comparable to a monofocal IOL, even in the presence of refractive error, thus matching the design expectations of the EDF IOL.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Desenho de Prótese , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Estudos Prospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Percepção de Profundidade/fisiologia , Pseudofacia/fisiopatologia , Erros de Refração/fisiopatologia , Facoemulsificação , Satisfação do Paciente , Simulação por Computador , Refração Ocular/fisiologia , Astigmatismo/fisiopatologia , Visão Binocular/fisiologia
17.
BMC Ophthalmol ; 24(1): 116, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38481203

RESUMO

BACKGROUND: To investigate the prevalence and risk factors for astigmatism in 7-19-year-old students in Xinjiang, China. METHODS: A school-based, cross-sectional study was conducted on students who underwent refraction examination in Xinjiang, China, between May and December 2019. The prevalence of astigmatism was determined. Astigmatism was defined as cylinder power (C) ≤-0.75 D, undefined astigmatism as ≤-1.50 D, and high astigmatism as C ≤-3.00 D. Astigmatism types were: against-the-rule astigmatism (maximum refraction of the main meridian in 180° ± 30°), with-the-rule astigmatism (maximum refraction of the main meridian at 90°±30°), and oblique astigmatism (all other cases). RESULTS: Of the 71,838 students examined (51.0% boys, 7 - 19 years old), 25,945 (36.1%, 95%CI: 35.52-36.68%) had astigmatism and 1267 (1.8%, 95%CI: 1.07-2.53%) had high astigmatism. The prevalence of astigmatism was greater in Han individuals (39.6%) compared with the Hui (34.0%), Kazakh (34.0%), Kyrgyz (32.1%), and Uyghur (26.4%) populations. Among the 25,945 students with astigmatism, 19,947 had with-the-rule astigmatism (76.9%), 3405 had against-the-rule astigmatism (13.1%), and 2593 had oblique astigmatism (10.0%). Multivariable logistic regression analysis showed that ethnicity (Han individuals more susceptible), male gender, age, and refractive errors (myopia and hyperopia) were independently associated with astigmatism, high astigmatism, and with-the-rule astigmatism (all P < 0.05). CONCLUSIONS: The prevalence of astigmatism among children and adolescents in Xinjiang was 36.1%, including 1.8% of high astigmatism. In this population, astigmatism was mainly of the with-the-rule astigmatism type (76.9%). Han ethnicity, male gender, and myopia or hyperopia were independently associated with a high risk of astigmatism.


Assuntos
Astigmatismo , Hiperopia , Miopia , Erros de Refração , Criança , Adolescente , Humanos , Masculino , Adulto Jovem , Adulto , Feminino , Astigmatismo/epidemiologia , Astigmatismo/diagnóstico , Estudos Transversais , Prevalência , Erros de Refração/epidemiologia , Miopia/epidemiologia , Estudantes , Fatores de Risco , China/epidemiologia
18.
Sci Rep ; 14(1): 6787, 2024 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-38514709

RESUMO

The aim of this study was to investigate the anatomical and physiological ocular parameters in adolescents with myopia and to examine the relations between refractive error (SER), ocular biometry, body size and flexibility parameters in myopic adolescents. A cross-sectional study of 184 myopic adolescents, aged 15 to 19 years was conducted. Refractive error and corneal curvature measures of the eye were evaluated using an autorefractometer under cycloplegia. Central corneal thickness was determined by contact pachymetry. The ocular axial length, anterior and vitreous chamber depth, and lens thickness were measured using A-scan biometry ultrasonography. Height and body weight were measured according to a standardized protocol. Body mass index (BMI) was subsequently calculated. Beighton scale was used to measure joint flexibility. Body stature was positively correlated with ocular axial length (r = 0.39, p < 0.001) and vitreous chamber depth (r = 0.37, p < 0.001). There was a negative correlation between height and SER (r = - 0.46; p < 0.001). Beighton score and body weight had weak positive correlations with axial length and vitreous chamber depth, and a weak negative correlation with SER. A significantly more negative SER was observed in the increased joint mobility group (p < 0.05; U = 5065.5) as compared to normal joint mobility group: mean - 4.37 ± 1.85 D (median - 4.25; IQR - 6.25 to - 3.25 D) and mean - 3.72 ± 1.66 D (median - 3.50; IQR - 4.75 to - 2.25 D) respectively. There was a strong association between height and axial length, as well as SER. Higher degree of myopia significantly correlated with greater Beighton score (increased joint mobility).


Assuntos
Miopia , Erros de Refração , Adolescente , Humanos , Estudos Transversais , Olho/diagnóstico por imagem , Biometria , Peso Corporal , Segmento Anterior do Olho , Refração Ocular , Câmara Anterior/diagnóstico por imagem , Câmara Anterior/anatomia & histologia , Comprimento Axial do Olho/diagnóstico por imagem
19.
BMC Pediatr ; 24(1): 202, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38515102

RESUMO

BACKGROUND: Undetected vision problems are common in school children, and a prevalence of up to 40% has previously been reported. Uncorrected vision and lack of optimal eye wear can have a significant impact on almost all aspects of everyday life, such as development and learning, academic performance, pain and discomfort, and quality of life. This study aimed to analyze the relationship between uncorrected vision problems, educational outcomes, and musculoskeletal pain symptoms. METHODS: A total of 152 school children (15.1 ± 0.8 years, mean ± SD; 40% males) were included in the study. All participants were recruited from a free-of-charge school vision testing program in Kathmandu, Nepal. Academic grades were collected from the school records of the participants' nationwide final grade examinations. A questionnaire was used to record the use of digital devices, screen time, and associated symptoms, including musculoskeletal pain (Wong-Baker FACES Pain Rating Scales). RESULTS: A total of 61 children (40%) had uncorrected vision, with a cycloplegic refraction of SER - 0.53 ± 0.52 (mean ± SD). Children with uncorrected vision had significantly more third division grades (26 vs. 9%, p = 0.004) and shoulder pain in general/during screen use (66 vs. 43/40%, p = 0.008/0.003; 2.1/1.9 vs. 1.1/1.0 mean pain score, p = 0.002/0.001) compared with children with normal vision. Sex based subanalyses showed that only girls with uncorrected vision had more third division grades (25 vs. 4%, p = 0.006), and only boys with uncorrected vision had more shoulder pain in general/during screen use (76 vs. 28/31%, p < 0.001; 2.2/2.4 vs. 0.7 mean pain score, p < 0.001), compared with children with normal vision. CONCLUSIONS: The results of this study showed that even small refractive errors may impact educational outcomes and musculoskeletal pain in adolescents. Most of the participating children had low myopia, easily corrected with glasses. This suggests that regular eye examinations are important in school children, and there is a need for raised awareness among parents, and school- and healthcare personnel.


Assuntos
Desempenho Acadêmico , Dor Musculoesquelética , Erros de Refração , Masculino , Criança , Feminino , Humanos , Adolescente , Acuidade Visual , Dor Musculoesquelética/diagnóstico , Dor de Ombro , Qualidade de Vida , Erros de Refração/diagnóstico , Erros de Refração/epidemiologia , Prevalência
20.
PLoS One ; 19(3): e0298960, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38527026

RESUMO

INTRODUCTION: The increasing prevalence of refractive error has become a serious health issue that needs serious attention. However, there are few studies regarding the prevalence and associated factors of refractive error at the community level in Ethiopia as well as in the study area. Therefore, providing updated data is crucial to reduce the burdens of refractive error in the community. OBJECTIVE: To assess the prevalence and associated factors of refractive error among adults in Hawassa City, South Ethiopia, 2023. METHOD: A community-based cross-sectional study was conducted on 951 adults using a multistage sampling technique from May 8 to June 8, 2023, in Hawassa City, South Ethiopia. A pretested, structured questionnaire combined with an ocular examination and a refraction procedure was used to collect data. The collected data from the Kobo Toolbox was exported to a statistical package for social sciences for analysis. Binary and multivariable logistic regression analyses were performed. A P-value of less than 0.05 was considered statistically significant in the multivariable analysis. RESULT: A total of 894 study participants were involved in this study with a 94.1% response rate. The prevalence of refractive error was 12.3% (95% CI: 10.2, 14.5%). Regular use of electronic devices (adjusted odds ratio = 3.64, 95% CI: 2.25, 5.91), being diabetic (adjusted odds ratio = 4.02, 95% CI: 2.16, 7.48), positive family history of refractive error (adjusted odds ratio = 2.71, 95% CI 1.59, 4.61) and positive history of cataract surgery (adjusted odds ratio = 5.17, 95% CI 2.19, 12.4) were significantly associated with refractive error. CONCLUSION AND RECOMMENDATION: The overall magnitude of refractive error in our study area was high. Regular use of electronic devices, being diabetic, positive family history of refractive error, and a positive history of cataract surgery were associated with refractive error.


Assuntos
Catarata , Diabetes Mellitus , Erros de Refração , Adulto , Humanos , Estudos Transversais , Etiópia/epidemiologia , Prevalência , Fatores de Risco , Erros de Refração/epidemiologia , Catarata/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...