Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.897
Filtrar
2.
World J Gastroenterol ; 30(16): 2272-2280, 2024 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-38690021

RESUMO

BACKGROUND: The magnetic compression technique has been used to establish an animal model of tracheoesophageal fistula (TEF), but the commonly shaped magnets present limitations of poor homogeneity of TEF and poor model control. We designed a T-shaped magnet system to overcome these problems and verified its effectiveness via animal experiments. AIM: To investigate the effectiveness of a T-shaped magnet system for establishing a TEF model in beagle dogs. METHODS: Twelve beagles were randomly assigned to groups in which magnets of the T-shaped scheme (study group, n = 6) or normal magnets (control group, n = 6) were implanted into the trachea and esophagus separately under gastroscopy. Operation time, operation success rate, and accidental injury were recorded. After operation, the presence and timing of cough and the time of magnet shedding were observed. Dogs in the control group were euthanized after X-ray and gastroscopy to confirm establishment of TEFs after coughing, and gross specimens of TEFs were obtained. Dogs in the study group were euthanized after X-ray and gastroscopy 2 wk after surgery, and gross specimens were obtained. Fistula size was measured in all animals, and then harvested fistula specimens were examined by hematoxylin and eosin (HE) and Masson trichrome staining. RESULTS: The operation success rate was 100% for both groups. Operation time did not differ between the study group (5.25 min ± 1.29 min) and the control group (4.75 min ± 1.70 min; P = 0.331). No bleeding, perforation, or unplanned magnet attraction occurred in any animal during the operation. In the early postoperative period, all dogs ate freely and were generally in good condition. Dogs in the control group had severe cough after drinking water at 6-9 d after surgery. X-ray indicated that the magnets had entered the stomach, and gastroscopy showed TEF formation. Gross specimens of TEFs from the control group showed the formation of fistulas with a diameter of 4.94 mm ± 1.29 mm (range, 3.52-6.56 mm). HE and Masson trichrome staining showed scar tissue formation and hierarchical structural disorder at the fistulas. Dogs in the study group did not exhibit obvious coughing after surgery. X-ray examination 2 wk after surgery indicated fixed magnet positioning, and gastroscopy showed no change in magnet positioning. The magnets were removed using a snare under endoscopy, and TEF was observed. Gross specimens showed well-formed fistulas with a diameter of 6.11 mm ± 0.16 mm (range, 5.92-6.36 mm), which exceeded that in the control group (P < 0.001). Scar formation was observed on the internal surface of fistulas by HE and Masson trichrome staining, and the structure was more regular than that in the control group. CONCLUSION: Use of the modified T-shaped magnet scheme is safe and feasible for establishing TEF and can achieve a more stable and uniform fistula size compared with ordinary magnets. Most importantly, this model offers better controllability, which improves the flexibility of follow-up studies.


Assuntos
Modelos Animais de Doenças , Imãs , Traqueia , Fístula Traqueoesofágica , Animais , Cães , Fístula Traqueoesofágica/cirurgia , Fístula Traqueoesofágica/patologia , Fístula Traqueoesofágica/etiologia , Traqueia/cirurgia , Traqueia/patologia , Esôfago/cirurgia , Esôfago/patologia , Esôfago/diagnóstico por imagem , Gastroscopia/instrumentação , Gastroscopia/métodos , Duração da Cirurgia , Masculino , Magnetismo/instrumentação , Desenho de Equipamento , Humanos
3.
Radiat Oncol ; 19(1): 55, 2024 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-38735947

RESUMO

BACKGROUND: Currently, automatic esophagus segmentation remains a challenging task due to its small size, low contrast, and large shape variation. We aimed to improve the performance of esophagus segmentation in deep learning by applying a strategy that involves locating the object first and then performing the segmentation task. METHODS: A total of 100 cases with thoracic computed tomography scans from two publicly available datasets were used in this study. A modified CenterNet, an object location network, was employed to locate the center of the esophagus for each slice. Subsequently, the 3D U-net and 2D U-net_coarse models were trained to segment the esophagus based on the predicted object center. A 2D U-net_fine model was trained based on the updated object center according to the 3D U-net model. The dice similarity coefficient and the 95% Hausdorff distance were used as quantitative evaluation indexes for the delineation performance. The characteristics of the automatically delineated esophageal contours by the 2D U-net and 3D U-net models were summarized. Additionally, the impact of the accuracy of object localization on the delineation performance was analyzed. Finally, the delineation performance in different segments of the esophagus was also summarized. RESULTS: The mean dice coefficient of the 3D U-net, 2D U-net_coarse, and 2D U-net_fine models were 0.77, 0.81, and 0.82, respectively. The 95% Hausdorff distance for the above models was 6.55, 3.57, and 3.76, respectively. Compared with the 2D U-net, the 3D U-net has a lower incidence of delineating wrong objects and a higher incidence of missing objects. After using the fine object center, the average dice coefficient was improved by 5.5% in the cases with a dice coefficient less than 0.75, while that value was only 0.3% in the cases with a dice coefficient greater than 0.75. The dice coefficients were lower for the esophagus between the orifice of the inferior and the pulmonary bifurcation compared with the other regions. CONCLUSION: The 3D U-net model tended to delineate fewer incorrect objects but also miss more objects. Two-stage strategy with accurate object location could enhance the robustness of the segmentation model and significantly improve the esophageal delineation performance, especially for cases with poor delineation results.


Assuntos
Aprendizado Profundo , Esôfago , Humanos , Esôfago/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos
4.
Clin Nucl Med ; 49(6): 576-577, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38498663

RESUMO

ABSTRACT: We present 2 cases of diffuse FDG accumulation in the esophagus due to drinking hot water before an 18 F-FDG PET/CT scan. Drinking large volume of hot water immediately before the FDG PET/CT study may lead to challenges in the interpretation of the hypermetabolic esophagus.


Assuntos
Esôfago , Fluordesoxiglucose F18 , Temperatura Alta , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Água , Humanos , Fluordesoxiglucose F18/farmacocinética , Água/metabolismo , Masculino , Temperatura Alta/efeitos adversos , Esôfago/diagnóstico por imagem , Esôfago/metabolismo , Pessoa de Meia-Idade , Feminino , Ingestão de Líquidos , Idoso , Transporte Biológico
5.
Kyobu Geka ; 77(3): 217-221, 2024 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-38465495

RESUMO

A 51-year-old man visited to our hospital because of chest discomfort and hematemesis. He was diagnosed with Mallory-Weiss syndrome and followed in outpatient clinic. One week later, he visited our hospital again for fever and discomfort. Chest computed tomography (CT) showed a foreign body perforated in the mediastinum in the upper esophagus, and he was urgently hospitalized for surgical removal of esophageal foreign body. Before surgery he vomited the esophageal foreign body with a lot of blood. Hematemesis was stopped spontaneously and contrast-enhanced CT revealed a pseudoaneurysm in the distal aortic arch, so thoracic endovascular aortic repair (TEVAR) was performed to prevent rupture. Esophageal endoscopy found that the site of esophageal injury healed spontaneously, so the patient was followed conservatively with antibiotics. He was discharged on postoperative day 18 uneventfully. TEVAR was an effective treatment for aortic injury caused by esophageal foreign body in our case.


Assuntos
Doenças da Aorta , Procedimentos Endovasculares , Corpos Estranhos , Masculino , Humanos , Pessoa de Meia-Idade , Hematemese/complicações , Esôfago/diagnóstico por imagem , Esôfago/cirurgia , Doenças da Aorta/cirurgia , Corpos Estranhos/complicações , Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/cirurgia
6.
J Pediatr Gastroenterol Nutr ; 78(5): 1155-1160, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38482943

RESUMO

Unsedated transnasal endoscopy (TNE) is an alternative method of examining the esophageal mucosa in pediatric patients with eosinophilic esophagitis (EoE), reducing cost, time, and risk associated with frequent surveillance esophagogastroduodenoscopies (EGD). Adequacy of transnasal esophageal biopsies for the evaluation of eosinophilic esophagitis histologic scoring system (EoEHSS) has not yet been evaluated. We compared procedure times, endoscopic findings, and EoEHSS scoring for EoE patients undergoing TNE versus standard EGD. Sixty-six TNE patients and 132 EGD controls matched for age (mean age 14.0 years) and disease status (29.3% active) were included. Compared to patients undergoing standard EGD, patients undergoing TNE spent 1.94 h less in the GI suite (p < 0.0001), with comparable occurrence rates of all visual endoscopic findings and most EoEHSS components. TNE serves as a useful tool for long-term disease surveillance, and consideration should be given to its use in clinical trials for EoE.


Assuntos
Esofagite Eosinofílica , Humanos , Esofagite Eosinofílica/diagnóstico , Esofagite Eosinofílica/patologia , Masculino , Adolescente , Feminino , Criança , Endoscopia do Sistema Digestório/métodos , Biópsia/métodos , Esofagoscopia/métodos , Esôfago/patologia , Esôfago/diagnóstico por imagem , Estudos de Casos e Controles
7.
J Pediatr ; 268: 113933, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38309524

RESUMO

OBJECTIVE: To compare the short- and long-term outcomes of infants with hypoxic-ischemic encephalopathy (HIE) treated with whole-body therapeutic hypothermia (TH), monitored by esophageal vs rectal temperature. STUDY DESIGN: We conducted a secondary analysis of the multicenter High-Dose Erythropoietin for Asphyxia and Encephalopathy (HEAL) trial. All infants had moderate or severe HIE and were treated with whole-body TH. The primary outcome was death or neurodevelopmental impairment (NDI) at 22-36 months of age. Secondary outcomes included seizures, evidence of brain injury on magnetic resonance imaging, and complications of hypothermia. Logistic regression was used with adjustment for disease severity and site as clustering variable because cooling modality differed by site. RESULTS: Of the 500 infants who underwent TH, 294 (59%) and 206 (41%) had esophageal and rectal temperature monitoring, respectively. There were no differences in death or NDI, seizures, or evidence of injury on magnetic resonance imaging between the 2 groups. Infants treated with TH and rectal temperature monitoring had lower odds of overcooling (OR 0.52, 95% CI 0.34-0.80) and lower odds of hypotension (OR 0.57, 95% CI 0.39-0.84) compared with those with esophageal temperature monitoring. CONCLUSIONS: Although infants undergoing TH with esophageal monitoring were more likely to experience overcooling and hypotension, the rate of death or NDI was similar whether esophageal monitoring or rectal temperature monitoring was used. Further studies are needed to investigate whether esophageal temperature monitoring during TH is associated with an increased risk of overcooling and hypotension.


Assuntos
Temperatura Corporal , Esôfago , Hipotermia Induzida , Hipóxia-Isquemia Encefálica , Reto , Humanos , Hipotermia Induzida/métodos , Hipóxia-Isquemia Encefálica/terapia , Masculino , Feminino , Recém-Nascido , Lactente , Esôfago/diagnóstico por imagem , Resultado do Tratamento , Monitorização Fisiológica/métodos , Imageamento por Ressonância Magnética , Pré-Escolar
8.
J Pediatr Gastroenterol Nutr ; 78(3): 601-607, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38305079

RESUMO

OBJECTIVES: Perforation of esophagus or stomach is a potential complication during and after insertion of a gastric tube in neonates. The aim of this study was to analyze different types of gastric tubes in a three-dimensional (3D) model of neonatal esophagus and stomach regarding potential perforations. METHODS: A 3D model of esophagus and stomach was created based on computed tomography data of a term neonate. Three types of gastric tubes were inserted into the 3D model, the localization was examined by radioscopy and the behavior, stiffness and manageability of each gastric tube was evaluated. RESULTS: Insertion of gastric tubes with higher stiffness was easier. The rates of correct localization differed significantly between the gastric tubes with the highest rate of correct localization in the softest tube (48.5%) and the lowest rate in the tube with the highest stiffness (21.2%). Additionally, the softest tube showed the lowest rate of localization of its tip at the stomach wall. CONCLUSIONS: The study illustrates differences between various types of gastric tubes regarding stiffness, behavior and resiliency. Softer gastric tubes may be beneficial. These differences may be relevant in neonatal care of very immature and very sick infants.


Assuntos
Esôfago , Estômago , Recém-Nascido , Lactente , Humanos , Estômago/diagnóstico por imagem , Esôfago/diagnóstico por imagem , Nutrição Enteral/métodos , Intubação Gastrointestinal/métodos
10.
Prague Med Rep ; 125(1): 47-55, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38380453

RESUMO

We present a case of a preterm neonate with a type IV laryngo-tracheo-oesophageal cleft, an uncommon congenital malformation, resulting from the failure of separation of the trachea and the oesophagus during fetal development, often associated with other deformities as well. Data in the literature shows that the long-term morbidity from the entity has declined over the last decades, even though prognosis remains unfavourable for types III and IV. This report emphasizes the complex issues neonatologists are faced with, when treating neonates with this rare disorder in the first days of life, what will raise suspicion of this rare medical entity, and that direct laryngoscopy/bronchoscopy finally depicts the exact extension of the medical condition. At the same time extensive evaluation for coexisting congenital anomalies should be performed. For all the above reasons, these neonates should be treated in specialized tertiary pediatric centers for multidisciplinary prompt management, which may improve, the outcome.


Assuntos
Anormalidades Congênitas , Laringe , Laringe/anormalidades , Recém-Nascido , Humanos , Criança , Laringe/diagnóstico por imagem , Laringe/cirurgia , Traqueia/diagnóstico por imagem , Traqueia/cirurgia , Traqueia/anormalidades , Esôfago/diagnóstico por imagem , Esôfago/cirurgia , Esôfago/anormalidades , Laringoscopia
11.
J Investig Med High Impact Case Rep ; 12: 23247096241231634, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38361358

RESUMO

Bilothorax, an exudative pleural effusion due to the accumulation of bile. It is also called cholethorax or thoracobilia and was initially reported in 1971. Here, we report a rare case of an elderly male presenting with bilateral bilothorax due to esophageal rupture. A 78-year-old man with multiple medical ailments presented to the emergency room (ER) with a severe episode of vomiting accompanied by a popping sound, respiratory distress, and right sided chest pain. The patient had tachycardia, BP of 101/89 mm Hg, and tachypnea. Computed tomography scan of the chest and abdomen revealed air adjacent to the esophagus, suggesting perforation, atelectasis of right lung, and bilateral pleural effusion (R > L). However, an esophagram did not reveal any perforation. Right-sided chest tube drained dark green bilious fluid. The day after admission, he experienced hemodynamic compromise and hypoxemia requiring intubation, along with fluids and inotropes support. Diagnosis of bilateral bilothorax complicated by hypoxemic respiratory failure with septic shock was made. Cultures were drawn, and empiric antibiotics were started. Nuclear hepatobiliary scan (HIDA) was performed to rule out a hepatobiliary fistula. Results showed reflux activity in the stomach, and distal esophageal leak was identified. Gastrojejunal stenting was performed. However, after prolonged intubation, the family decided on terminal extubation, and he died while receiving hospice care. This case highlights the rarity of bilateral bilothorax, where the HIDA scan played a crucial role in identifying an esophageal leak as the underlying cause, despite normal esophagram results. This condition necessitates prompt diagnosis and aggressive therapeutic interventions.


Assuntos
Iminoácidos , Derrame Pleural , Humanos , Masculino , Idoso , Derrame Pleural/etiologia , Esôfago/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Bile
12.
J Int Med Res ; 52(1): 3000605231224231, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38217419

RESUMO

Measuring patients' core body temperature during surgery is essential and commonly performed with an esophageal temperature probe. The probe must be placed in the lower third of the esophagus for accurate measurement. In this case report, we describe our experience of discovering an inadvertently malpositioned esophageal temperature probe in the right inferior lobar bronchus, which led to ventilation-related problems in a patient undergoing prostate surgery.


Assuntos
Laparoscopia , Neoplasias da Próstata , Robótica , Masculino , Humanos , Próstata , Temperatura Corporal , Temperatura , Prostatectomia/efeitos adversos , Esôfago/diagnóstico por imagem , Esôfago/cirurgia , Neoplasias da Próstata/cirurgia
14.
Int J Pediatr Otorhinolaryngol ; 176: 111803, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38043185

RESUMO

INTRODUCTION: Button batteries (BB) are a source of significant morbidity and mortality in young children. Little data is available regarding associations between esophageal impaction location and outcomes or need for surveillance imaging. METHODS: All patients treated at a single institution following BB ingestion between 2018 and 2022 were included for retrospective chart review. RESULTS: Twenty patients were treated at our institution BBs were located, or most significant damage observed, in the cervical esophagus (n = 10, 50 %), followed by thoracic esophagus (n = 6, 30 %), and abdominal esophagus (n = 4, 20 %). Patients with cervical esophageal impaction were younger (482 [370-866] days), than those with thoracic (1395 [871-2369] days) or abdominal esophageal impaction (2021.5 [1230.5-3419.5] days) (p = 0.003). Zargar Mucosal Injury Grade was significantly more severe in patients with cervical button battery impaction; 8/10 (80 %) had a ≥Grade IIIB injury, compared to 2/6 (33.3 %) thoracic impactions and 0/4 (0 %) abdominal impactions (p = 0.002). All patients who developed persistent esophageal stenosis (n = 6) had cervical battery impactions (6, 60 %, p = 0.015). Both TEFs (2/2) had anterior facing anode, while both (2/2) esophageal perforations had posterior. Only 1/20 (5 %) patients, and 1/7 (14.3 %) with serious complications, had a serious complication detected on routine, rather than clinically indicated follow-up surveillance. CONCLUSIONS: In our population, cervical BB impaction occurred more frequently in younger children, was associated with more severe mucosal injury, and had higher risk of stenosis. Nearly all complications were detected on clinically indicated rather than postoperative surveillance imaging.


Assuntos
Corpos Estranhos , Criança , Humanos , Pré-Escolar , Estudos Retrospectivos , Corpos Estranhos/complicações , Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/cirurgia , Esôfago/diagnóstico por imagem , Esôfago/lesões , Fontes de Energia Elétrica , Ingestão de Alimentos
20.
Gastrointest Endosc ; 99(1): 108-115.e1, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37739237

RESUMO

BACKGROUND AND AIMS: Ultrathin EGD (UT-EGD) is an ideal tool for unsedated upper GI examination and pediatric gastroenterology but is rarely competent for EUS miniprobe (EUS-MP). We developed a UT-EGD US method (UT-EUS) and verified its clinical application value through animal experiments. METHODS: Five Bama miniature pigs were selected. Using an acoustic medium, we performed US on the duodenum, stomach, and esophagus, respectively, with conventional 20-MHz EUS miniprobe (EUS-MP-20), 20-MHz UT-EUS (UT-EUS-20), and 30-MHz UT-EUS (UT-EUS-30). The times to acquire 5 consecutive stable US images, number of identifiable wall layers, and quality and penetration depth of the images were recorded. RESULTS: No significant differences were found in the time required to obtain images between EUS-MP-20 and UT-EUS-20 at each site (P > .05). UT-EUS-30 showed more wall levels than UT-EUS-20 (P < .05). No significant differences were noted between EUS-MP-20 and UT-EUS-20 in imaging quality and penetration depth (P > .05). CONCLUSIONS: The UT-EUS is easy to use with a satisfactory image quality and has potential clinical application value.


Assuntos
Endoscopia do Sistema Digestório , Ultrassom , Humanos , Criança , Suínos , Animais , Endoscopia do Sistema Digestório/métodos , Endoscópios , Endossonografia/métodos , Esôfago/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...