Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 978
Filtrar
1.
Sensors (Basel) ; 24(9)2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38732837

RESUMO

The gut microbiota and its related metabolites differ between inflammatory bowel disease (IBD) patients and healthy controls. In this study, we compared faecal volatile organic compound (VOC) patterns of paediatric IBD patients and controls with gastrointestinal symptoms (CGIs). Additionally, we aimed to assess if baseline VOC profiles could predict treatment response in paediatric IBD patients. We collected faecal samples from a cohort of de novo therapy-naïve paediatric IBD patients and CGIs. VOCs were analysed using gas chromatography-ion mobility spectrometry (GC-IMS). Response was defined as a combination of clinical response based on disease activity scores, without requiring treatment escalation. We included 109 paediatric IBD patients and 75 CGIs, aged 4 to 17 years. Faecal VOC profiles of paediatric IBD patients were distinguishable from those of CGIs (AUC ± 95% CI, p-values: 0.71 (0.64-0.79), <0.001). This discrimination was observed in both Crohn's disease (CD) (0.75 (0.67-0.84), <0.001) and ulcerative colitis (UC) (0.67 (0.56-0.78), 0.01) patients. VOC profiles between CD and UC patients were not distinguishable (0.57 (0.45-0.69), 0.87). Baseline VOC profiles of responders did not differ from non-responders (0.70 (0.58-0.83), 0.1). In conclusion, faecal VOC profiles of paediatric IBD patients differ significantly from those of CGIs.


Assuntos
Fezes , Doenças Inflamatórias Intestinais , Espectrometria de Mobilidade Iônica , Compostos Orgânicos Voláteis , Humanos , Compostos Orgânicos Voláteis/análise , Criança , Fezes/química , Adolescente , Feminino , Masculino , Estudos de Casos e Controles , Pré-Escolar , Espectrometria de Mobilidade Iônica/métodos , Doenças Inflamatórias Intestinais/metabolismo , Doença de Crohn/metabolismo , Colite Ulcerativa/metabolismo , Cromatografia Gasosa-Espectrometria de Massas/métodos , Microbioma Gastrointestinal/fisiologia
2.
J Physiol Pharmacol ; 75(2): 215-222, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38736268

RESUMO

The analysis of volatile organic compounds (VOCs) present in various biological samples holds immense potential for non-invasive disease diagnostics and metabolic profiling. One of the biological fluids that are suitable for use in clinical practice is urine. Given the limited quantity of VOCs in the urine headspace, it's imperative to enhance their extraction into the gaseous phase and prevent any degradation of VOCs during the thawing process. The study aimed to test several key parameters (incubation time, temperature, and thawing) that can influence urine volatilome and monitor selected VOCs for their stability. The analysis in this study was performed using a BreathSpec® (G.A.S., Dortmund, Germany) device consisting of a gas chromatograph (GC) coupled with an ion mobility spectrometer (IMS). Testing three different temperatures and incubation times yielded a low number of VOCs (9 out of 34) that exhibited statistically significant differences. However, examining three thawing conditions revealed no VOCs with statistically significant changes. Thus, we conclude that urine composition remains relatively stable despite exposure to various thermal stresses.


Assuntos
Espectrometria de Mobilidade Iônica , Compostos Orgânicos Voláteis , Compostos Orgânicos Voláteis/urina , Compostos Orgânicos Voláteis/análise , Humanos , Projetos Piloto , Espectrometria de Mobilidade Iônica/métodos , Masculino , Adulto , Cromatografia Gasosa-Espectrometria de Massas/métodos , Feminino , Temperatura , Adulto Jovem , Pessoa de Meia-Idade
3.
J Chromatogr A ; 1725: 464931, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38703457

RESUMO

Atractylodis rhizoma is a common bulk medicinal material with multiple species. Although different varieties of atractylodis rhizoma exhibit variations in their chemical constituents and pharmacological activities, they have not been adequately distinguished due to their similar morphological features. Hence, the purpose of this research is to analyze and characterize the volatile organic compounds (VOCs) in samples of atractylodis rhizoma using multiple techniques and to identify the key differential VOCs among different varieties of atractylodis rhizoma for effective discrimination. The identification of VOCs was carried out using headspace solid-phase microextraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS) and headspace gas chromatography-ion mobility spectrometry (HS-GC-IMS), resulting in the identification of 60 and 53 VOCs, respectively. The orthogonal partial least squares discriminant analysis (OPLS-DA) model was employed to screen potential biomarkers and based on the variable importance in projection (VIP ≥ 1.2), 24 VOCs were identified as critical differential compounds. Random forest (RF), K-nearest neighbor (KNN) and back propagation neural network based on genetic algorithm (GA-BPNN) models based on potential volatile markers realized the greater than 90 % discriminant accuracies, which indicates that the obtained key differential VOCs are reliable. At the same time, the aroma characteristics of atractylodis rhizoma were also analyzed by ultra-fast gas chromatography electronic nose (Ultra-fast GC E-nose). This study indicated that the integration of HS-SPME-GC-MS, HS-GC-IMS and ultra-fast GC E-nose with chemometrics can comprehensively reflect the differences of VOCs in atractylodis rhizoma samples from different varieties, which will be a prospective tool for variety discrimination of atractylodis rhizoma.


Assuntos
Atractylodes , Nariz Eletrônico , Cromatografia Gasosa-Espectrometria de Massas , Microextração em Fase Sólida , Compostos Orgânicos Voláteis , Compostos Orgânicos Voláteis/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Microextração em Fase Sólida/métodos , Atractylodes/química , Espectrometria de Mobilidade Iônica/métodos , Rizoma/química , Análise Discriminante
4.
Protein Sci ; 33(6): e5008, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38723181

RESUMO

One of the most important attributes of anti-amyloid antibodies is their selective binding to oligomeric and amyloid aggregates. However, current methods of examining the binding specificities of anti-amyloid ß (Aß) antibodies have limited ability to differentiate between complexes that form between antibodies and monomeric or oligomeric Aß species during the dynamic Aß aggregation process. Here, we present a high-resolution native ion-mobility mass spectrometry (nIM-MS) method to investigate complexes formed between a variety of Aß oligomers and three Aß-specific IgGs, namely two antibodies with relatively high conformational specificity (aducanumab and A34) and one antibody with low conformational specificity (crenezumab). We found that crenezumab primarily binds Aß monomers, while aducanumab preferentially binds Aß monomers and dimers and A34 preferentially binds Aß dimers, trimers, and tetrameters. Through collision induced unfolding (CIU) analysis, our data indicate that antibody stability is increased upon Aß binding and, surprisingly, this stabilization involves the Fc region. Together, we conclude that nIM-MS and CIU enable the identification of Aß antibody binding stoichiometries and provide important details regarding antibody binding mechanisms.


Assuntos
Peptídeos beta-Amiloides , Anticorpos Monoclonais Humanizados , Espectrometria de Mobilidade Iônica , Peptídeos beta-Amiloides/química , Peptídeos beta-Amiloides/imunologia , Peptídeos beta-Amiloides/metabolismo , Anticorpos Monoclonais Humanizados/química , Anticorpos Monoclonais Humanizados/imunologia , Anticorpos Monoclonais Humanizados/metabolismo , Espectrometria de Mobilidade Iônica/métodos , Humanos , Espectrometria de Massas/métodos , Ligação Proteica , Anticorpos Monoclonais/química , Anticorpos Monoclonais/imunologia , Multimerização Proteica
5.
J Breath Res ; 18(3)2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38701772

RESUMO

The analysis of volatile organic compounds (VOCs) in exhaled air has attracted the interest of the scientific community because it provides the possibility of monitoring physiological and metabolic processes and non-invasive diagnostics of various diseases. However, this method remains underused in clinical practice as well as in research because of the lack of standardized procedures for the collection, storage and transport of breath samples, which would guarantee good reproducibility and comparability of results. The method of sampling, as well as the storage time of the breath samples in the polymer bags used for sample storage and transport, affect the composition and concentration of VOCs present in the breath samples. The aim of our study was to compare breath samples obtained using two methods with fully disposable equipment: a Haldane sampling tube intended for direct breath collection and breath samples exhaled into a transparent Tedlar bag. The second task was to monitor the stability of selected compounds of real breath samples stored in a Tedlar bag for 6 h. Gas chromatography coupled with ion mobility spectrometry (GC-IMS) implemented in the BreathSpec®device was used to analyse exhaled breath. Our results showed a significant difference in the signal intensity of some volatiles when taking a breath sample with a Haldane tube and a Tedlar bag. Due to its endogenous origin, acetone levels were significantly higher when the Haldane tube sampler was used while elevated levels of 2-propanol and unidentified VOC (designated as VOC 3) in the Tedlar bag samples likely originated from contamination of the Tedlar bags. The VOC stability study revealed compound-specific signal intensity changes of the selected VOCs with storage time in the Tedlar bags, with some volatiles showing increasing signal intensity during storage in Tedlar bags. This limits the use of Tedlar bags only for very limited time and carefully selected purpose. Our results highlight the importance of careful design and implementation of experiments and clinical protocols to obtain relevant and reliable results.


Assuntos
Testes Respiratórios , Manejo de Espécimes , Compostos Orgânicos Voláteis , Humanos , Testes Respiratórios/instrumentação , Testes Respiratórios/métodos , Compostos Orgânicos Voláteis/análise , Manejo de Espécimes/instrumentação , Manejo de Espécimes/métodos , Espectrometria de Mobilidade Iônica/métodos , Espectrometria de Mobilidade Iônica/instrumentação , Masculino , Feminino , Reprodutibilidade dos Testes , Adulto , Cromatografia Gasosa-Espectrometria de Massas/métodos , Cromatografia Gasosa-Espectrometria de Massas/instrumentação , Expiração , Pessoa de Meia-Idade , Fatores de Tempo
6.
Anal Chem ; 96(19): 7380-7385, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38693701

RESUMO

Ion mobility-mass spectrometry (IM-MS) offers benefits for lipidomics by obtaining IM-derived collision cross sections (CCS), a conditional property of an ion that can enhance lipid identification. While drift tube (DT) IM-MS retains a direct link to the primary experimental method to derive CCS values, other IM technologies rely solely on external CCS calibration, posing challenges due to dissimilar chemical properties between lipids and calibrants. To address this, we introduce MobiLipid, a novel tool facilitating the CCS quality control of IM-MS lipidomics workflows by internal standardization. MobiLipid utilizes a newly established DTCCSN2 library for uniformly (U)13C-labeled lipids, derived from a U13C-labeled yeast extract, containing 377 DTCCSN2 values. This automated open-source R Markdown tool enables internal monitoring and straightforward compensation for CCSN2 biases. It supports lipid class- and adduct-specific CCS corrections, requiring only three U13C-labeled lipids per lipid class-adduct combination across 10 lipid classes without requiring additional external measurements. The applicability of MobiLipid is demonstrated for trapped IM (TIM)-MS measurements of an unlabeled yeast extract spiked with U13C-labeled lipids. Monitoring the CCSN2 biases of TIMCCSN2 values compared to DTCCSN2 library entries utilizing MobiLipid resulted in mean absolute biases of 0.78% and 0.33% in positive and negative ionization mode, respectively. By applying the CCS correction integrated into the tool for the exemplary data set, the mean absolute CCSN2 biases of 10 lipid classes could be reduced to approximately 0%.


Assuntos
Lipidômica , Lipídeos , Espectrometria de Massas , Lipidômica/métodos , Lipídeos/química , Lipídeos/análise , Espectrometria de Mobilidade Iônica/métodos , Controle de Qualidade , Padrões de Referência , Saccharomyces cerevisiae/química , Saccharomyces cerevisiae/metabolismo
7.
J Mass Spectrom ; 59(6): e5039, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38747242

RESUMO

Utilizing a data-driven approach, this study investigates modifier effects on compensation voltage in differential mobility spectrometry-mass spectrometry (DMS-MS) for metabolites and peptides. Our analysis uncovers specific factors causing signal suppression in small molecules and pinpoints both signal suppression mechanisms and the analytes involved. In peptides, machine learning models discern a relationship between molecular weight, topological polar surface area, peptide charge, and proton transfer-induced signal suppression. The models exhibit robust performance, offering valuable insights for the application of DMS to metabolites and tryptic peptides analysis by DMS-MS.


Assuntos
Espectrometria de Mobilidade Iônica , Metabolômica , Peptídeos , Metabolômica/métodos , Peptídeos/química , Peptídeos/análise , Espectrometria de Mobilidade Iônica/métodos , Espectrometria de Massas/métodos , Aprendizado de Máquina , Proteômica/métodos , Peso Molecular
8.
Molecules ; 29(7)2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38611949

RESUMO

Olibanum is a resinous traditional Chinese medicine that is directly used as a powder. It is widely used in China and is often combined with other traditional Chinese medicine powders to promote blood circulation and relieve pain, as well as to treat rheumatism, rheumatoid arthritis, and osteoarthritis. Powdered traditional Chinese medicine is often easily contaminated by microorganisms and 60Co irradiation is one of the good sterilization methods. Volatile organic compounds (VOCs) are the main active ingredient of olibanum. The aim of this study was to validate the optimum doses of 60Co irradiation and its effect on VOCs. 60Co irradiation was applied in different doses of 0 kGy, 1.5 kGy, 3.0 kGy, and 6.0 kGy. Changes in VOCs were detected using gas chromatography ion mobility spectrometry. A total of 81 VOCs were identified. The odor fingerprint results showed that, with an increase in irradiation dose, most of the VOCs of olibanum changed. Through principal component analysis, cluster analysis, and partial least squares discriminant analysis, it was demonstrated that, at 1.5 kGy, the impact of radiation on the VOCs of olibanum was minimal, indicating this is a relatively good irradiation dose. This study provides a theoretical basis for the irradiation processing and quality control of resinous medicinal materials such as olibanum and it also provides a good reference for irradiation technology development and its application to functional foods, thus making it both significant from a research perspective and useful from an application perspective.


Assuntos
Radioisótopos de Cobalto , Franquincenso , Compostos Orgânicos Voláteis , Espectrometria de Mobilidade Iônica , Cromatografia Gasosa-Espectrometria de Massas , Resinas Vegetais
9.
Anal Chem ; 96(14): 5589-5597, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38556723

RESUMO

Sebum lipids are composed of nonpolar lipids, and they pose challenges for mass spectrometry-based analysis due to low ionization efficiency and the existence of numerous isomers and isobars. To address these challenges, we have developed ethyl 2-oxo-2-(pyridine-3-yacetate as a charge-tagging Paternò-Büchi reagent and Michler's ketone as a highly efficient photocatalyst, achieving ∼90% conversion for C═C derivatization under 440 nm LED irradiation. This derivatization, when coupled with electrospray ionization-tandem mass spectrometry, boosts the detection of sebum lipids and pinpoints C═C location in a chain-specific fashion. Identification and quantitation of isomers are readily achieved for wax esters, a class of underexplored sebum lipids, which have C═C bonds distributed in fatty alcohol and fatty acyl chains. A shotgun analysis workflow has been developed by pairing the offline PB derivatization with cyclic ion mobility spectrometry-mass spectrometry. Besides the dominant n-10 C═C location in unsaturated wax esters, profiling of low abundance isomers, including the rarely reported n-7 and n-13 locations, is greatly enhanced due to separations of C═C diagnostic ions by ion mobility. Over 900 distinct lipid structures from human sebum lipid extract have been profiled at the chain-specific C═C level, including wax esters (500), glycerolipids (393), and cholesterol esters (22), far more exceeding previous reports. Overall, we have developed a fast and comprehensive lipidomic profiling tool for sebum samples, a type of noninvasive biofluids holding potential for the discovery of disease markers in distal organs.


Assuntos
Lipídeos , Sebo , Humanos , Lipídeos/análise , Sebo/química , Espectrometria de Mobilidade Iônica , Lipidômica , Espectrometria de Massas por Ionização por Electrospray/métodos , Íons
10.
Anal Chim Acta ; 1304: 342534, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38637035

RESUMO

The traceability of in vitro diagnostics or drug products is based on the accurate quantification of proteins. In this study, we developed an absolute quantification approach for proteins. This method is based on calibrated particle counting using electrospray-differential mobility analysis (ES-DMA) coupled with a condensation particle counter (CPC). The absolute concentration of proteins was quantified with the observed protein particle number measured with ES-DMA-CPC, and the detection efficiency was determined by calibrators. The measurement performance and quantitative level were verified using two certificated reference materials, BSA and NIMCmAb. The linear regression fit for the detection efficiency values of three reference materials and one highly purified protein (myoglobin, BSA, NIMCmAb and fibrinogen) indicated that the detection efficiency and the particle size distribution of these proteins exhibited a linear relationship. Moreover, to explore the suitability of the detection efficiency-particle size curve for protein quantification, the concentrations of three typical proteinaceous particles, including two high molecular weight proteins (NIST reference material 8671 and D-dimer) and one protein complex (glutathione S-transferase dimer), were determined. This work suggests that this calibrated particle counting method is an efficient approach for nondestructive, rapid and accurate quantification of proteins, especially for measuring proteinaceous particles with tremendous size and without reference standards.


Assuntos
Espectrometria de Mobilidade Iônica , Mioglobina , Tamanho da Partícula , Glutationa Transferase , Ouro
11.
J Chromatogr A ; 1722: 464903, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38615559

RESUMO

High-Field Asymmetric Ion Mobility Spectrometry (FAIMS) is a technique for ion separation and detection based on ion mobility variation under high electronic field. While compensation voltage scanning speed is a fundamental parameter in FAIMS, its impact on spectra remains unclear. In this work, a function referred to as F-EMG is introduced to describe the impact of compensation voltage scanning speed on FAIMS spectra, and the properties of the function are studied. Theoretical analysis emphasizes the impact of the scanning speed on peak height, position, and symmetry, as well as the capability of the F-EMG function to progressively approach Gaussian function at lower scanning speeds. Furthermore, the function indicates that spectra obtained in positive and negative scanning modes exhibits symmetry. An experimental validation, conducted with a custom FAIMS setup and analyzing hydrogen sulfide, ethylbenzene, toluene, styrene, benzene and ammonia, confirms the model's influence on peak features, fitting accuracy, and exhibits a closer alignment with the Gaussian function at lower scanning speeds. Additionally, the experimental data indicate that the spectra show symmetry in positive and negative scanning models. This work not only improves understanding of FAIMS spectral analysis but also introduces a robust method for enhancing data accuracy across varying scanning speeds.


Assuntos
Espectrometria de Mobilidade Iônica , Espectrometria de Mobilidade Iônica/métodos , Modelos Teóricos , Íons/química , Íons/análise
12.
Molecules ; 29(8)2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38675693

RESUMO

Further assessment of ultraviolet C light-emitting diode (UVC-LED) irradiation for influencing shiitake mushrooms' (Lentinus edodes) volatile and sensory properties is needed. In this study, a comparison of UVC-LED irradiation treatment on the flavor profiles in various parts of shiitake mushrooms was conducted using gas chromatography-ion mobility spectrometry (GC-IMS) and sensory analysis. Sixty-three volatile compounds were identified in shiitake mushrooms. The fresh shiitake mushrooms were characterized by the highest values of raw mushroom odors. After UVC-LED treatment, the content of C8 alcohols decreased, especially that of 1-octen-3-ol, while the content of aldehydes increased, especially the content of nonanal and decanal. The score of fatty and green odors was enhanced. For fresh samples, the mushroom odors decreased and the mushroom-like odors weakened more sharply when treated in ethanol suspension than when treated with direct irradiation. The fruit odors were enhanced using direct UVC-LED irradiation for fresh mushroom samples and the onion flavor decreased. As for shiitake mushroom powder in ethanol suspension treated with UVC-LED, the sweaty and almond odor scores decreased and the vitamin D2 content in mushroom caps and stems reached 668.79 µg/g (dw) and 399.45 µg/g (dw), respectively. The results obtained from this study demonstrate that UVC-LED treatment produced rich-flavored, quality mushroom products.


Assuntos
Odorantes , Cogumelos Shiitake , Raios Ultravioleta , Compostos Orgânicos Voláteis , Cogumelos Shiitake/química , Compostos Orgânicos Voláteis/análise , Odorantes/análise , Espectrometria de Mobilidade Iônica/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos
13.
J Mass Spectrom ; 59(5): e5026, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38656572

RESUMO

Identification and specific quantification of isomers in a complex biological matrix by mass spectrometry alone is not an easy task due to their identical chemical formula and therefore their same mass-to-charge ratio (m/z). Here, the potential of direct introduction combined with ion mobility-mass spectrometry (DI-IM-MS) for rapid quantification of isomers as human milk oligosaccharides (HMOs) was investigated. Differences in HMO profiles between various analyzed breast milk samples were highlighted using the single ion mobility monitoring (SIM2) acquisition for high ion mobility resolution detection. Furthermore, the Se+ (secretor) or Se- (non-secretor) phenotype could be assigned to breast milk samples studied based on their HMO contents, especially on the response of 2'-fucosyllactose (2'-FL) and lacto-N-fucopentaose I (LNFP I). The possibility of quantifying a specific isomer in breast milk by DI-IM-MS was also investigated. The standard addition method allowed the determination of the 2'-FL despite the presence of other oligosaccharides, including 3-fucosyllactose (3-FL) isomer in breast milk. This proof-of-concept study demonstrated the high potential of such an approach for the rapid and convenient quantification of isomers in complex mixtures.


Assuntos
Espectrometria de Mobilidade Iônica , Leite Humano , Oligossacarídeos , Trissacarídeos , Leite Humano/química , Humanos , Trissacarídeos/análise , Trissacarídeos/química , Oligossacarídeos/análise , Oligossacarídeos/química , Isomerismo , Feminino , Espectrometria de Mobilidade Iônica/métodos , Espectrometria de Massas/métodos
14.
J Am Soc Mass Spectrom ; 35(5): 982-991, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38597281

RESUMO

The structural characterization and differentiation of four types of oligoubiquitin conjugates [linear (Met1)-, Lys11-, Lys48-, Lys63-linked di-, tri-, and tetraubiquitin chains] using ion mobility mass spectrometry are reported. A comparison of collision cross sections for the same linkage of di-, tri-, and tetraubiquitin chains shows differences in conformational elongation for higher charge states due to the interplay of linkage-derived structure and Coulombic repulsion. For di- and triubiquitin chains, this elongation results in a single narrow feature representing an elongated conformation type for multiple higher charge state species. In contrast, higher charge state tetraubiquitin species do not form a single conformer type as readily. A comparison of different linkages in tetraubiquitin chains reveals greater similarity in conformation type at lower charge states; with increasing charge state, the four linkage types diverge in the relative proportions of elongated conformer types with Met1- ≥ Lys11- > Lys63- > Lys48-linkage. These differences in conformational trends could be discussed with respect to biological functions of linkage-specific polyubiquitinated proteins.


Assuntos
Espectrometria de Mobilidade Iônica , Ubiquitina , Espectrometria de Mobilidade Iônica/métodos , Ubiquitina/química , Conformação Proteica , Espectrometria de Massas/métodos , Modelos Moleculares , Lisina/química
15.
J Am Soc Mass Spectrom ; 35(5): 1012-1020, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38634722

RESUMO

To understand the mode of action of bioactive oligosaccharides, such as prebiotics, in-depth knowledge about all structural features, including monosaccharide composition, linkage type, and anomeric configuration, is necessary. Current analytical techniques provide limited information about structural features within complex mixtures unless preceded by extensive purification. In this study, we propose an approach employing cyclic ion mobility spectrometry (cIMS) for the in-depth characterization of oligosaccharides, here demonstrated for disaccharides. We were able to separate galactose and glucose anomers by exploiting the high ion mobility resolution of cIMS. Using the obtained monosaccharide mobilograms as references, we determined the composition and anomeric configuration of 4ß-galactobiose by studying the monosaccharide fragments generated by collision-induced dissociation (CID) before the ion mobility separation. Drift times and individual MS2 spectra of partially resolved reducing-end anomers of 4ß-galactobiose, 4ß-galactosylglucose (lactose), and 4ß-glucosylglucose (cellobiose) were obtained by deconvolution using CID fragmentation induced in the transfer region between the cIMS cell and TOF analyzer. The composition and anomeric configuration of the reducing end anomers of these disaccharides were identified using cIMS2 approaches, where first each anomer was isolated using cIMS and individually fragmented, and the monosaccharide fragments were again separated by cIMS for comparison with monosaccharide standards. With these results we demonstrate the promising application of cIMS for the structural characterization of isomeric oligosaccharides.


Assuntos
Dissacarídeos , Espectrometria de Mobilidade Iônica , Monossacarídeos , Espectrometria de Mobilidade Iônica/métodos , Dissacarídeos/química , Monossacarídeos/química , Configuração de Carboidratos
16.
Sci Total Environ ; 929: 172483, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38631629

RESUMO

Per- and polyfluoroalkyl substances (PFAS) remain controversial due to their high persistency and potential human toxicity. Although occupational exposure to PFAS has been widely investigated, the implications of PFAS occurrence in the general population remain to be unraveled. Considering that serum from most people contains PFAS, the aim of this study was to characterize the lipidomic profile in human serum from a general cohort (n = 40) with residual PFAS levels. The geometric means of ∑PFAS (11.8 and 4.4 ng/mL) showed significant differences (p < 0.05) for the samples with the highest (n = 20) and lowest (n = 20) concentrations from the general population respectively. Reverse-phase liquid chromatography coupled to drift tube ion mobility and high-resolution mass spectrometry using dual polarity ionization was used to characterize the lipid profile in both groups. The structural elucidation involved the integration of various parameters, such as retention time, mass-to-charge ratio, tandem mass spectra and collision cross section values. This approach yielded a total of 20 potential biomarkers linked to the perturbed glycerophospholipid metabolism, energy metabolism and sphingolipid metabolism. Among these alterations, most lipids were down-regulated and some specific lipids (PC 36:5, PC 37:4 and PI O-34:2) exhibited a relatively strong Spearman correlation and predictive capacity for PFAS contamination. This study could support further toxicological assessments and mechanistic investigations into the effects of PFAS exposure on the lipidome.


Assuntos
Poluentes Ambientais , Fluorocarbonos , Lipidômica , Humanos , Fluorocarbonos/sangue , Poluentes Ambientais/sangue , Cromatografia Líquida , China , Espectrometria de Massas , Estudos de Coortes , Adulto , Masculino , Exposição Ambiental/estatística & dados numéricos , Feminino , Pessoa de Meia-Idade , Espectrometria de Mobilidade Iônica/métodos , Lipídeos/sangue , Monitoramento Ambiental/métodos , População do Leste Asiático
17.
Anal Chem ; 96(18): 7111-7119, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38648270

RESUMO

Unsaturated lipids constitute a significant portion of the lipidome, serving as players of multifaceted functions involving cellular signaling, membrane structure, and bioenergetics. While derivatization-assisted liquid chromatography tandem mass spectrometry (LC-MS/MS) remains the gold standard technique in lipidome, it mainly faces challenges in efficiently labeling the carbon-carbon double bond (C═C) and differentiating isomeric lipids in full dimension. This presents a need for new orthogonal methodologies. Herein, a metal- and additive-free aza-Prilezhaev aziridination (APA)-enabled ion mobility mass spectrometric method is developed for probing multiple levels of unsaturated lipid isomerization with high sensitivity. Both unsaturated polar and nonpolar lipids can be efficiently labeled in the form of N-H aziridine without significant side reactions. The signal intensity can be increased by up to 3 orders of magnitude, achieving the nM detection limit. Abundant site-specific fragmentation ions indicate C═C location and sn-position in MS/MS spectra. Better yet, a stable monoaziridination product is dominant, simplifying the spectrum for lipids with multiple double bonds. Coupled with a U-shaped mobility analyzer, identification of geometric isomers and separation of different lipid classes can be achieved. Additionally, a unique pseudo MS3 mode with UMA-QTOF MS boosts the sensitivity for generating diagnostic fragments. Overall, the current method provides a comprehensive solution for deep-profiling lipidomics, which is valuable for lipid marker discovery in disease monitoring and diagnosis.


Assuntos
Aziridinas , Lipídeos , Aziridinas/química , Lipídeos/química , Lipídeos/análise , Isomerismo , Espectrometria de Massas em Tandem/métodos , Espectrometria de Mobilidade Iônica/métodos
18.
J Mass Spectrom ; 59(5): e5013, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38605450

RESUMO

Ion mobility spectrometry coupled to mass spectrometry (IMS/MS) is a widely used tool for biomolecular separations and structural elucidation. The application of IMS/MS has resulted in exciting developments in structural proteomics and genomics. This perspective gives a brief background of the field, addresses some of the important issues in making structural measurements, and introduces complementary techniques.


Assuntos
Proteínas , Proteômica , Proteínas/análise , Espectrometria de Massas/métodos , Espectrometria de Mobilidade Iônica/métodos
19.
J Mass Spectrom ; 59(5): e5021, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38605451

RESUMO

Trapped ion mobility spectrometry-time-of-flight mass spectrometry (TIMS-TOFMS) has emerged as a tool to study protein conformational states. In TIMS, gas-phase ions are guided across the IM stages by applying direct current (DC) potentials (D1-6), which, however, might induce changes in protein structures through collisional activation. To define conditions for native protein analysis, we evaluated the influence of these DC potentials using the metalloenzyme bovine carbonic anhydrase (BCA) as primary test compound. The variation of DC potentials did not change BCA-ion charge and heme content but affected (relative) charge-state intensities and adduct retention. Constructed extracted-ion mobilograms and corresponding collisional cross-section (CCS) profiles gave useful insights in (alterations of) protein conformational state. For BCA, the D3 and D6 potential (which are applied between the deflection transfer and funnel 1 [F1] and the accumulation exit and the start of the ramp, respectively) had most profound effects, showing multimodal CCS distributions at higher potentials indicating gradual unfolding. The other DC potentials only marginally altered the CCS profiles of BCA. To allow for more general conclusions, five additional proteins of diverse molecular weight and conformational stability were analyzed, and for the main protein charge states, CCS profiles were constructed. Principal component analysis (PCA) of the obtained data showed that D1 and D3 exhibit the highest degree of correlation with the ratio of folded and unfolded protein (F/U) as extracted from the mobilograms obtained per set D potential. The correlation of D6 with F/U and protein charge were similar, and D2, D4, and D5 showed an inverse correlation with F/U but were correlated with protein charge. Although DC boundary values for induced conformational changes appeared protein dependent, a set of DC values could be determined, which assured native analysis of most proteins.


Assuntos
Espectrometria de Mobilidade Iônica , Proteínas , Animais , Bovinos , Espectrometria de Mobilidade Iônica/métodos , Espectrometria de Massas/métodos , Conformação Proteica , Proteínas/química , Íons
20.
Molecules ; 29(5)2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38474610

RESUMO

Milk fat is a premium nutritional health product, yet there is a lack of high-fat dairy products for daily consumption in the current market. This study investigated the influence of different milk fat contents on the physicochemical and textural properties of fermented milk. The research revealed that an increase in milkfat content significantly improved the water-holding capacity, syneresis, color, hardness, springiness, gumminess, and chewiness of fermented milk, while showing minimal changes in pH and total titratable acidity. Response surface analysis indicated that fermented milk with 25% milk fat, 2.5% inoculum, a fermentation time of 16 h, and a fermentation temperature of 30 °C exhibited the highest overall acceptability. Using GC-IMS technology, 36 volatile compounds were identified, with an increase in milk fat content leading to elevated levels of ketone compounds, and 14 compounds were defined as key aroma compounds (ROAV > 1). Electronic nose distinguished samples with different milk fat contents. The results demonstrate that an increase in milk fat content enhances the physicochemical and flavor attributes of fermented milk. This work provides theoretical references for the production and development of high-fat fermented milk.


Assuntos
Espectrometria de Mobilidade Iônica , Leite , Animais , Leite/química , Cromatografia Gasosa-Espectrometria de Massas , Análise Multivariada , Cetonas/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...