Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.380
Filtrar
1.
Ophthalmol Retina ; 8(2): 204-206, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38707762

RESUMO

Oral ingestion of fluorescein can be done in ambulatory pediatric clinics. We show that oral ultra-widefield fluorescein angiography is a non-invasive approach to rapidly diagnose and manage a diverse set of pediatric retinal vascular diseases.


Assuntos
Angiofluoresceinografia , Fluoresceína , Fundo de Olho , Doenças Retinianas , Humanos , Angiofluoresceinografia/métodos , Criança , Doenças Retinianas/diagnóstico , Fluoresceína/administração & dosagem , Masculino , Feminino , Adolescente , Vasos Retinianos/diagnóstico por imagem , Pré-Escolar , Instituições de Assistência Ambulatorial , Administração Oral
2.
Neurosurg Rev ; 47(1): 181, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38649501

RESUMO

The treatment for peripheral nerve sheath tumors (PNSTs) is based on surgical excision and the primary goal is to improve symptoms whilst preserving neurological function. In order to improve this technique, surgeons may use sodium fluorescein (SF) to help visualize the neoplasm and, consequently, facilitate its removal. Aiming to assess the efficacy of this emerging surgical strategy, we conducted a systematic review and single-arm meta-analysis. We conducted a systematic search on the PubMed, Embase, and Web of Science databases, following the PRISMA guidelines. Studies without outcomes of interest, case series with less than four patients, letters, comments, technical notes, editorials, reviews, and basic research papers were excluded. The outcomes considered for this study were: the number of tumors that achieved total resection, subtotal resection, or near total resection, the approach/technique utilized by the surgeon, SF-related complications, and total complications. Five studies, with a total of 175 individuals, were included in our survey. Notably, 70% of the neoplasms presented by the patients were schwannomas. Considering extracranial lesions, we found a proportion of 96% (95% CI: 88 - 100%) in total resection, 0% (95% CI: 0-1%) in near total resection, and 4% (95% CI: 0-12%) in subtotal resection, all linked to an amount of 185 analyzed PNSTs. Furthermore, a proportion of 1% (95% CI: 0 - 2%) in SF-related complications was spotted among 183 patients. Finally, total complications analysis accounted for 11% (95% CI: 0 - 25%) among 183 individuals. We concluded that SF-assisted resection of PNSTs is a suitable and relatively safe technique, linked to minimum complications, of which the majority was not associated with the chemical compound itself. Future research is necessary to increase the number of patients available in the current literature and, therefore, enhance future analyses.


Assuntos
Fluoresceína , Neoplasias de Bainha Neural , Procedimentos Neurocirúrgicos , Humanos , Corantes Fluorescentes , Neoplasias de Bainha Neural/cirurgia , Procedimentos Neurocirúrgicos/métodos
3.
Sensors (Basel) ; 24(7)2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38610526

RESUMO

Gold nanoparticles (AuNPs) are good candidates for donor material in energy transfer systems and can easily be functionalized with various ligands on the surface with Au-S bonding. Cyclodextrin (CD) forms inclusion complexes with fluorophores due to its unique structure for host-guest interaction. In this study, we fabricated ßCD-functionalized AuNPs using different lengths of thiol ligands and recognized cholesterol to confirm the energy-transfer-based turn-on fluorescence mechanism. AuNP-ßCD conjugated with various thiol ligands and quenched the fluorescein (Fl) dye, forming ßCD-Fl inclusion complexes. As the distance between AuNPs and ßCD decreased, the quenching efficiency became higher. The quenched fluorescence was recovered when the cholesterol replaced the Fl because of the stronger binding affinity of the cholesterol with ßCD. The efficiency of cholesterol recognition was also affected by the energy transfer effect because the shorter ßCD ligand had a higher fluorescence recovery. Furthermore, we fabricated a liposome with cholesterol embedded in the lipid bilayer membrane to mimic the cholesterol coexisting with lipids in human serum. These cellular cholesterols accelerated the replacement of the Fl molecules, resulting in a fluorescence recovery higher than that of pure lipid. These discoveries are expected to give guidance towards cholesterol sensors or energy-transfer-based biosensors using AuNPs.


Assuntos
Ouro , Nanopartículas Metálicas , Humanos , Colesterol , Transferência de Energia , Fluoresceína , Compostos de Sulfidrila
4.
Methods Mol Biol ; 2794: 21-32, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38630217

RESUMO

Immunohistochemistry (IHC) is the basis of histological or pathological analysis and is widely used to enable the detection and characterization of proteins in various organ tissues, including brain tissues. IHC is commonly performed on formalin-fixed paraffin-embedded (FFPE) tissues because of their easy storage and versatility. IHC is a key method for providing more accurate analysis of localization and function of neurons, neuroendocrine cells, and neural stem cells in the brain and other nervous systems. The related cells such as glial cells and neurovascular units have also been analyzed by IHC. Visualization of antibody-antigen interactions can be performed primarily in one of the following ways: chromogenically stained IHC and fluorescently stained IHC. In chromogenically stained IHC, an antibody is chemically conjugated to an enzyme, such as peroxidase, that can be reacted with a suitable substrate to give a colored product. In fluorescently stained IHC, the antibodies are finally tagged with fluorescent chemicals such as fluorescein isothiocyanate (FITC) or rhodamine. Here, we describe the standard methods of IHC applied to brain slice sections. Furthermore, an automated immunostainer is presented as another option for standardized immunohistochemistry.


Assuntos
Anticorpos , Encéfalo , Imuno-Histoquímica , Corantes , Fluoresceína
5.
BMC Ophthalmol ; 24(1): 155, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594682

RESUMO

INTRODUCTION: In recent years, insulin eye drops have attracted increasing attention from researchers and ophthalmologists. The aim of this study was to investigate the efficacy and possible mechanism of action of insulin eye drops in diabetic mice with corneal wounds. METHODS: A type 1 diabetes model was induced, and a corneal epithelial injury model of 2.5 mm was established. We used corneal fluorescein staining, hematoxylin-eosin (H-E) staining and the Cochet-Bonnet esthesiometer to examine the process of wound healing. Subsequently, the expression levels of Ki-67, IL-1ß, ß3-tubulin and neuropeptides, including substance P (SP) and calcitonin gene-related peptide (CGRP), were examined at 72 h after corneal injury. RESULTS: Fluorescein staining demonstrated an acceleration of the recovery of corneal epithelial injury in diabetic mice compared with the saline treatment, which was further evidenced by the overexpression of Ki-67. Moreover, 72 h of insulin application attenuated the expression of inflammatory cytokines and neutrophil infiltration. Remarkably, the results demonstrated that topical insulin treatment enhanced the density of corneal epithelial nerves, as well as neuropeptide SP and CGRP release, in the healing cornea via immunofluorescence staining. CONCLUSIONS: Our results indicated that insulin eye drops may accelerate corneal wound healing and decrease inflammatory responses in diabetic mice by promoting nerve regeneration and increasing levels of neuropeptides SP and CGRP.


Assuntos
Lesões da Córnea , Diabetes Mellitus Experimental , Epitélio Corneano , Ceratite , Camundongos , Animais , Epitélio Corneano/metabolismo , Insulina , Diabetes Mellitus Experimental/complicações , Diabetes Mellitus Experimental/tratamento farmacológico , Diabetes Mellitus Experimental/metabolismo , Peptídeo Relacionado com Gene de Calcitonina/metabolismo , Soluções Oftálmicas , Antígeno Ki-67/metabolismo , Córnea/fisiologia , Lesões da Córnea/tratamento farmacológico , Cicatrização , Ceratite/metabolismo , Fluoresceína/metabolismo , Inflamação/metabolismo
6.
Cells ; 13(5)2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38474422

RESUMO

Chlorine (Cl2) exposure poses a significant risk to ocular health, with the cornea being particularly susceptible to its corrosive effects. Antioxidants, known for their ability to neutralize reactive oxygen species (ROS) and alleviate oxidative stress, were explored as potential therapeutic agents to counteract chlorine-induced damage. In vitro experiments using human corneal epithelial cells showed decreased cell viability by chlorine-induced ROS production, which was reversed by antioxidant incubation. The mitochondrial membrane potential decreased due to both low and high doses of Cl2 exposure; however, it was recovered through antioxidants. The wound scratch assay showed that antioxidants mitigated impaired wound healing after Cl2 exposure. In vivo and ex vivo, after Cl2 exposure, increased corneal fluorescein staining indicates damaged corneal epithelial and stromal layers of mice cornea. Likewise, Cl2 exposure in human ex vivo corneas led to corneal injury characterized by epithelial fluorescein staining and epithelial erosion. However, antioxidants protected Cl2-induced damage. These results highlight the effects of Cl2 on corneal cells using in vitro, ex vivo, and in vivo models while also underscoring the potential of antioxidants, such as vitamin A, vitamin C, resveratrol, and melatonin, as protective agents against acute chlorine toxicity-induced corneal injury. Further investigation is needed to confirm the antioxidants' capacity to alleviate oxidative stress and enhance the corneal healing process.


Assuntos
Antioxidantes , Lesões da Córnea , Humanos , Animais , Camundongos , Antioxidantes/metabolismo , Cloro/toxicidade , Espécies Reativas de Oxigênio/metabolismo , Córnea/metabolismo , Fluoresceína/farmacologia
7.
Skin Res Technol ; 30(3): e13655, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38481085

RESUMO

BACKGROUND: The stratum corneum (SC), the outermost layer of the skin epidermis, acts as an effective bi-directional barrier, preventing water loss (inside-outside barrier) and entry of foreign substances (outside-inside barrier). Although transepidermal water loss (TEWL) is a widely-used measure of barrier function, it represents only inside-outside protection. Therefore, we aimed to establish a non-invasive method for quantitative evaluation of the outside-inside barrier function and visually present a skin barrier model. MATERIALS AND METHODS: Skin barrier damage was induced by applying a closed patch of 1% sodium dodecyl sulfate to the forearms of eight participants; they were instructed to apply a barrier cream on a designated damaged area twice daily for 5 days. The SC barrier was evaluated by measuring TEWL and fluorescein sodium salt penetration rate before, immediately after, and 5 days after damage. The penetration rate was assessed using tape-stripping (TS) technique and fluorescence microscopy. RESULTS: The rates of fluorescein sodium salt penetration into the lower layers of SC differed significantly based on the degree of skin barrier damage. The correlation between penetration rate and TEWL was weak after two rounds of TS and became stronger after subsequent rounds. Five days after skin barrier damage, the penetration rate of all layers differed significantly between areas with and without the barrier cream application. CONCLUSION: Our findings demonstrated that the penetration rate was dependent on skin barrier conditions. The penetration rate and corresponding fluorescence images are suitable quantitative indicators that can visually represent skin barrier conditions.


Assuntos
Dermatopatias , Perda Insensível de Água , Humanos , Fluoresceína/metabolismo , Fluoresceína/farmacologia , Epiderme/metabolismo , Pele/metabolismo , Dermatopatias/metabolismo , Água/metabolismo , Emolientes/farmacologia
8.
Ocul Surf ; 32: 166-172, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38490476

RESUMO

AIM: To assess whether smaller increment and regionalised subjective grading improves the repeatability of corneal fluorescein staining assessment, and to determine the neurological approach adopted for subjective grading by practitioners. METHODS: Experienced eye-care practitioners (n = 28, aged 45 ± 12 years), graded 20 full corneal staining images of patients with mild to severe Sjögren's syndrome with the Oxford grading scheme (both in 0.5 and 1.0 increments, globally and in 5 regions), expanded National Eye Institute (NEI) and SICCA Ocular Staining Score (OSS) grading scales in randomised order. This was repeated after 7-10 days. The digital images were also analysed objectively to determine staining dots, area, intensity and location (using ImageJ) for comparison. RESULTS: The Oxford grading scheme was similar with whole and half unit grading (2.77vs2.81,p = 0.145), but the variability was reduced (0.14vs0.12,p < 0.001). Regional grade was lower (p < 0.001) and more variable (p < 0.001) than global image grading (1.86 ± 0.44 for whole increment grading and 1.90 ± 0.39 for half unit increments). The correlation with global grading was high for both whole (r = 0.928,p < 0.001) and half increment (r = 0.934,p < 0.001) grading. Average grading across participants was associated with particle number and vertical position, with 74.4-80.4% of the linear variance accounted for by the digital image analysis. CONCLUSIONS: Using half unit increments with the Oxford grading scheme improve its sensitivity and repeatability in recording corneal staining. Regional grading doesn't give a comparable score and increased variability. The key neurally extracted features in assigning a subjective staining grade by clinicians were identified as the number of discrete staining locations (particles) and how close to the vertical centre was their spread, across all three scales.


Assuntos
Córnea , Síndromes do Olho Seco , Síndrome de Sjogren , Coloração e Rotulagem , Humanos , Síndrome de Sjogren/diagnóstico , Síndrome de Sjogren/patologia , Síndrome de Sjogren/metabolismo , Pessoa de Meia-Idade , Córnea/patologia , Feminino , Coloração e Rotulagem/métodos , Masculino , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/metabolismo , Corantes Fluorescentes , Fluoresceína , Adulto , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
9.
Biosensors (Basel) ; 14(3)2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38534258

RESUMO

Two fluorescent molecularly imprinted polymers (MIPs) were developed for pepsin enzyme utilising fluorescein and rhodamine b. The main difference between both dyes is the presence of two (diethylamino) groups in the structure of rhodamine b. Consequently, we wanted to investigate the effect of these functional groups on the selectivity and sensitivity of the resulting MIPs. Therefore, two silica-based MIPs for pepsin enzyme were developed using 3-aminopropyltriethoxysilane as a functional monomer and tetraethyl orthosilicate as a crosslinker to achieve a one-pot synthesis. Results of our study revealed that rhodamine b dyed MIPs (RMIPs) showed stronger binding, indicated by a higher binding capacity value of 256 mg g-1 compared to 217 mg g-1 for fluorescein dyed MIPs (FMIPs). Moreover, RMIPs showed superior sensitivity in the detection and quantitation of pepsin with a linear range from 0.28 to 42.85 µmol L-1 and a limit of detection (LOD) as low as 0.11 µmol L-1. In contrast, FMIPs covered a narrower range from 0.71 to 35.71 µmol L-1, and the LOD value reached 0.34 µmol L-1, which is three times less sensitive than RMIPs. Finally, the developed FMIPs and RMIPs were applied to a separation-free quantification system for pepsin in saliva samples without interference from any cross-reactors.


Assuntos
Impressão Molecular , Pepsina A , Limite de Detecção , Fluoresceína , Corantes , Impressão Molecular/métodos
10.
Arq Bras Oftalmol ; 87(3): e20220220, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38537039

RESUMO

PURPOSE: This study aimed to investigate the effect of upper eyelid blepharoplasty with the removal of the skin and a strip of orbicularis oculi muscle on the ocular surface, tear film, and dry eye-related symptoms. METHODS: Twenty-two eyes of 22 consecutive patients operated by a single surgeon (21 females; mean age, 61 years; age range, 41-75 years) were included. All subjects completed the Ocular Surface Disease Index questionnaire, underwent in vivo confocal microscopy, tear film breakup time measurements, the Schirmer test with anesthesia, and fluorescein and lissamine green staining measurements before, 1 month, and 6 months after upper blepharoplasty alone with preseptal orbicularis excision. RESULTS: A significant increase in Ocular Surface Disease Index, and corneal fluorescein and lissamine green staining and a significant decrease in tear film breakup time were observed after 1 month (p=0.003, p=0.004, p=0.029, and p=0.024 respectively) and 6 months (p=0.001 for all findings). No significant difference in the Schirmer test score was observed during the follow-up. None of the in vivo confocal microscopy parameters showed significant changes during the study. CONCLUSIONS: An increase in dry eye symptoms and a decrease in tear film stability along with ocular surface staining were observed in patients undergoing upper eyelid blepharoplasty.


Assuntos
Blefaroplastia , Síndromes do Olho Seco , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Córnea/cirurgia , Pálpebras/cirurgia , Lágrimas/fisiologia , Síndromes do Olho Seco/diagnóstico , Fluoresceína
11.
Int J Mol Sci ; 25(6)2024 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-38542159

RESUMO

This article discusses the design and analysis of a new chemical chemosensor for detecting mercury(II) ions. The chemosensor is a hydrazone made from 4-methylthiazole-5-carbaldehyde and fluorescein hydrazide. The structure of the chemosensor was confirmed using various methods, including nuclear magnetic resonance spectroscopy, infrared spectroscopy with Fourier transformation, mass spectroscopy, and quantum chemical calculations. The sensor's ability in the highly selective and sensitive discovery of Hg2+ ions in water was demonstrated. The detection limit for mercury(II) ions was determined to be 0.23 µM. The new chemosensor was also used to detect Hg2+ ions in real samples and living cells using fluorescence spectroscopy. Chemosensor 1 and its complex with Hg2+ demonstrate a significant tendency to enter and accumulate in cells even at very low concentrations.


Assuntos
Mercúrio , Metais Pesados , Poluentes Químicos da Água , Fluoresceína , Água , Corantes Fluorescentes/química , Poluentes Químicos da Água/análise , Mercúrio/análise , Espectrometria de Fluorescência/métodos
12.
Int J Biol Macromol ; 265(Pt 2): 131011, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38518947

RESUMO

Preserving fish meat poses a significant challenge due to its high protein and low fat content. This study introduces a novel approach that utilizes a common type of lanthanide metal-organic frameworks (Ln-MOFs), EuMOFs, in combination with 5-fluorescein isothiocyanate (FITC) and methylcellulose (MC) to develop fluorescent sensor arrays for real-time monitoring the freshness of fish meat. The EuMOF-FITC/MC fluorescence films were characterized with excellent fluorescence response, ideal morphology, good mechanical properties, and improved hydrophobicity. The efficacy of the fluorescence sensor array was evaluated by testing various concentrations of spoilage gases (such as ammonia, dimethylamine, and trimethylamine) within a 20-min timeframe using a smartphone-based camera obscura device. This sensor array enables the real-time monitoring of fish freshness, with the ability to preliminarily identify the freshness status of mackerel meat with the naked eye. Furthermore, the study employed four convolutional neural network (CNN) models to enhance the performance of freshness assessment, all of which achieved accuracy levels exceeding 93 %. Notably, the ResNext-101 model demonstrated a particularly high accuracy of 98.97 %. These results highlight the potential of the EuMOF-based fluorescence sensor array, in conjunction with the CNN model, as a reliable and accurate method for real-time monitoring the freshness of fish meat.


Assuntos
Aprendizado Profundo , Isotiocianatos , Elementos da Série dos Lantanídeos , Animais , Fluoresceína-5-Isotiocianato , Peixes , Corantes , Fluoresceína
13.
JAMA Ophthalmol ; 142(4): 337-343, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38451509

RESUMO

Importance: Dry eye disease (DED) is a prevalent eye disorder. Cyclosporine is an effective immunomodulator that is widely used in DED; however, due to its highly hydrophobic nature, delivery of cyclosporine to the ocular surface is challenging. Objective: To evaluate the efficacy and safety of SHR8028, a water-free cyclosporine ophthalmic solution, 0.1%, compared with vehicle in Chinese participants with DED. Design, Setting, and Participants: This was a multicenter, double-blind, vehicle-controlled, phase 3 randomized clinical trial conducted from March 4, 2021, to July 22, 2022. Adult participants with moderate to severe DED were recruited from 12 hospitals in China. Study data were analyzed April 2, 2022, for the primary analysis. Interventions: Following a 14-day run-in period with an artificial tear, participants were randomly assigned (1:1) to receive water-free cyclosporine or vehicle (1 eye drop in each eye twice daily). After a 29-day treatment, participants of both groups were given the option to receive water-free cyclosporine for an additional 12 weeks for longer-term safety assessment. Main Outcomes and Measures: The primary end points were changes from baseline in total corneal fluorescein staining (tCFS) using the National Eye Institute scale and in dryness score on a visual analog scale at day 29. Results: A total of 206 participants (mean [SD] age, 47.8 [14.2] years; 185 female [90%]) were enrolled, with 103 each in the cyclosporine group and the vehicle group. At day 29, the cyclosporine group experienced improved tCFS compared with vehicle (change [Δ] = -1.8; 95% CI, -2.7 to -1.0; P < .001), with a tCFS score decrease from baseline of -4.8 in the cyclosporine group and -3.0 in the vehicle group. Dryness score decreased from baseline in both groups (-19.2 vs -15.4; Δ = -3.8; 95% CI, -9.2 to 1.6; P = .17). During the 29-day treatment, treatment-related adverse events were reported in 15 participants (14.6%) in the cyclosporine group and 11 participants (10.7%) in the vehicle group. Conclusions And Relevance: Results demonstrated superiority of a water-free cyclosporine, 0.1%, eye solution over vehicle in improving tCFS score at day 29 in Chinese participants with DED. However, dryness score (VAS) was not improved at day 29. Trial Registration: ClinicalTrials.gov Identifier: NCT05841043.


Assuntos
Ciclosporina , Síndromes do Olho Seco , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Ciclosporina/uso terapêutico , Método Duplo-Cego , Resultado do Tratamento , Fluoresceína , Soluções Oftálmicas/administração & dosagem , Lubrificantes Oftálmicos/uso terapêutico , Lágrimas
14.
Vestn Oftalmol ; 140(1): 58-64, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38450467

RESUMO

In recent years, among artificial tear preparations that have additional metabolic properties, in addition to moisturizing the ocular surface, there has been a drug Optinol Soft Recovery (LLC JADRAN). In addition to 0.15% sodium hyaluronate, it contains 2% dexpanthenol, which stimulates reparative regeneration of the corneal epithelium, in particular in patients with dry eye syndrome (DES). PURPOSE: This study evaluates the clinical efficacy of the drug Optinol Soft Recovery in the treatment of patients with DES accompanied by xerotic changes in the corneal epithelium. MATERIAL AND METHODS: The study included 82 patients (15 children and 65 adults) with moderate and severe DES accompanied by the following corneal pathology: filamentous keratitis (20 patients, 33 eyes), persistent corneal erosion (28 patients, 49 eyes) and punctate keratopathy (34 patients, 68 eyes). RESULTS: All patients receiving fourfold instillations of the studied drug were observed already during the first 7 days to have increased stability of the tear film and decreased severity of staining of the cornea and conjunctiva with vital dyes (0.1% sodium fluorescein and 3% lissamine green, respectively). Further, as the patients were transferred to an individual instillation regimen, a progressive decrease in the Ocular Surface Disease Index (OSDI), an increase in corneal sensitivity and tear meniscus index were also recorded. The differences in most parameters of the course of xerosis compared to the initial ones were statistically significant starting from day 10-20 of therapy, depending on the initial severity of corneal xerosis (p<0.05-0.001). CONCLUSION: Patients with moderate DES complicated by punctate keratopathy were the most susceptible to therapy with the drug Optinol Soft Recovery, while patients with filamentous keratitis secondary to a severe clinical form of DES were the least susceptible.


Assuntos
Úlcera da Córnea , Epitélio Corneano , Adulto , Criança , Humanos , Córnea , Túnica Conjuntiva , Fluoresceína
15.
World Neurosurg ; 185: e774-e785, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38432505

RESUMO

BACKGROUND: This study analyzed the effectiveness and safety of ultra-low dose fluorescein sodium (FL)-guided malignant glioma resection and its potential to predict the pathological characteristics of glioma. METHODS: Sixty patients who underwent FL-guided glioma resection were randomly divided into test (1 mg/kg) and control (5 mg/kg) groups. A retrospective analysis included 30 patients with gliomas who did not undergo FL-guided surgery; these patients were included as a blank control group. Surgical outcomes, Karnofsky performance scores (KPS), and progression-free survival (PFS) at 6 months postoperatively were compared between the 3 groups. The sensitivity and specificity of FL and the relationship between the intensity of FL and Glial fibrillary acidic protein (GFAP) or Ki-67 expression were compared. RESULTS: The total tumor resection rates in the test, control, and blank control groups were 90% (27/30), 86.7% (26/30), and 60% (18/30), respectively. There were significant differences (P < 0.05) in the extent of resection, KPS, and PFS at 6 months after surgery between the test and control groups and the blank control group; however, no significant differences (P > 0.05) were observed between the test and control groups. The intensity of FL and the Ki67 positivity rate (P < 0.05) were directly proportional, but this relationship was not observed with GFAP. CONCLUSIONS: Ultra-low-dose FL-guided resection of malignant gliomas is safe and effective. The Ki67 positivity rate was directly proportional to the intensity of FL, indicating its potential to predict gliomas during pathological examination.


Assuntos
Neoplasias Encefálicas , Fluoresceína , Glioma , Humanos , Glioma/cirurgia , Masculino , Feminino , Pessoa de Meia-Idade , Neoplasias Encefálicas/cirurgia , Adulto , Estudos Retrospectivos , Fluoresceína/administração & dosagem , Idoso , Resultado do Tratamento , Cirurgia Assistida por Computador/métodos , Antígeno Ki-67/metabolismo , Antígeno Ki-67/análise , Procedimentos Neurocirúrgicos/métodos , Proteína Glial Fibrilar Ácida/metabolismo , Corantes Fluorescentes/administração & dosagem
16.
Cont Lens Anterior Eye ; 47(2): 102127, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38350814

RESUMO

PURPOSE: The aim of this study was to evaluate the long-term effects of serial intravitreal injections (IVI) on measures of dry eye. METHODS: The PubMed, EMBASE, and Cochrane databases were searched according to the PROSPERO protocol (CRD42023455727). Studies evaluating the influence of serial IVI on the ocular surface compared with untreated fellow eyes were included. The measures of dry eye after IVI were used as outcome variables. The results are presented as mean difference (MD) with a corresponding 95% confidence interval (CI). RESULTS: A total of 4 studies with 259 participants were included in this meta-analysis. Significant increases in ocular surface disease index (OSDI) scores (MD 10.26, 95 % CI 5.05 to 15.46, p < 0.01) and tear film osmolarity (TOsm; MD 4.40, 95 % CI 0.87 to 7.92, p = 0.01) were observed in the IVI treated eyes compared to the untreated fellow eyes. There was no significant difference between the groups with respect to fluorescein tear film break-up time (TBUT; p = 0.05), average non-invasive tear film break-up time (NITBUT; p = 0.94), first NITBUT (p = 0.78) and Schirmer test (p = 0.94). CONCLUSION: Repeated IVI of anti-VEGF agents with preoperative povidone-iodine application was associated with increased OSDI scores and TOsm, while no significant difference was found in fluorescein TBUT, average NITBUT, first NITBUT and Schirmer test. The ocular surface may partially recover after the procedures, but IVI still has deleterious effects on the ocular surface.


Assuntos
Síndromes do Olho Seco , Humanos , Injeções Intravítreas , Síndromes do Olho Seco/tratamento farmacológico , Povidona-Iodo , Lágrimas , Fluoresceína
17.
J Fr Ophtalmol ; 47(3): 104073, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38320466

RESUMO

PURPOSE: To evaluate the results of using a pigtail probe to open the inferior punctum followed by bicanalicular silicone tube intubation in patients with severe acquired punctal stenosis. METHODS: Forty-one eyes of 25 patients with severe inferior punctal stenosis admitted to our tertiary care center were included in the study. The degree of epiphora was determined using the Munk score and the fluorescein disappearance test. The inferior punctum was located and opened by entering the superior punctum with a pigtail probe. Then, bicanalicular silicone tube intubation was performed. The silicone tube was removed after six months. A Munk score of 0 or 1 and a fluorescein disappearance test score of 1 and 2 were considered a complete success. RESULTS: Ten (40%) patients were male, and 15 (60%) were female. The mean age was 60.4±15.5years. One year after the surgery, epiphora was absent in 18 eyes (43.9%) (Munk score grade 0) and rarely seen in 9 eyes (22%) (Munk score grade 1). At the one-year follow-up, the fluorescein disappearance test score was stage 1 (<3min) in 21 eyes (51.2%) and stage 2 (3-5min) in 13 eyes (31.7%). There was a statistically significant difference between the preoperative and one-year postoperative test results (P<0.001). CONCLUSION: In cases with severe punctal stenosis, a pigtail probe is an effective method for locating and opening the punctum, and punctal opening and prevention of restenosis were achieved by a bicanalicular stent.


Assuntos
Doenças Palpebrais , Aparelho Lacrimal , Obstrução dos Ductos Lacrimais , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Silicones , Obstrução dos Ductos Lacrimais/diagnóstico , Obstrução dos Ductos Lacrimais/terapia , Constrição Patológica , Intubação/métodos , Aparelho Lacrimal/cirurgia , Fluoresceína
18.
In Vivo ; 38(2): 855-863, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38418139

RESUMO

BACKGROUND/AIM: The need for instant histological evaluation of fresh tissue, especially in cancer treatment, remains paramount. The conventional frozen section technique has inherent limitations, prompting the exploration of alternative methods. A recently developed confocal laser endomicroscopic system provides real-time imaging of the tissue without the need for glass slide preparation. Herein, we evaluated its applicability in the histologic evaluation of gastric cancer tissues. MATERIALS AND METHODS: A confocal laser endomicroscopic system (CLES) with a Lissajous pattern laser scanning, was developed. Fourteen fresh gastric cancer tissues and the same number of normal gastric tissues were obtained from advanced gastric cancer patients. Fluorescein sodium was used for staining. Five pathologists interpreted 100 endomicroscopic images and decided their histologic location and the presence of cancer. Following the review of matched hematoxylin and eosin (H&E) slides, their performance was evaluated with another 100 images. RESULTS: CLES images mirrored gastric tissue histology. Pathologists were able to detect the histologic location of the images with 65.7% accuracy and differentiate cancer tissue from normal with 74.7% accuracy. The sensitivity and specificity of cancer detection were 71.9% and 76.1%. Following the review of matched H&E images, the accuracy of identifying the histologic location was increased to 92.8% (p<0.0001), and that of detecting cancer tissue was also increased to 90.9% (p<0.001). The sensitivity and specificity of cancer detection were enhanced to 89.1% and 93.2% (p<0.0001). CONCLUSION: High-quality histological images were immediately acquired by the CLES. The operator training enabled the accurate detection of cancer and histologic location raising its potential applicability as a real-time tissue imaging modality.


Assuntos
Neoplasias Gástricas , Humanos , Neoplasias Gástricas/diagnóstico , Neoplasias Gástricas/patologia , Microscopia Confocal/métodos , Fluoresceína , Amarelo de Eosina-(YS) , Lasers
19.
BMJ Open ; 14(2): e078727, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38413161

RESUMO

INTRODUCTION: The lipid layer of the tear film is critical to maintaining the integrity of the tear film and absence in the tear film lipid layer (TFLL) is one of the main causes of evaporative dry eye (EDE) in dry eye disease patients, resulting in excessive evaporation (so-called hyperevaporative dry eye). This study protocol will be designed to assess and compare the effects of intense pulsed light (IPL), heated eye mask (HEM), vectored thermal pulsation system (VTPS) and eyelid massage device (EMD) for improving signs and symptoms of EDE. METHODS AND ANALYSIS: Patients with EDE will be randomly divided into IPL, HEM, VTPS and EMD groups and will be followed up for 6 weeks. The primary outcome measure will be non-invasive tear breakup time (NITBUT). The secondary outcome measures will include, TFLL score, meibomian gland quality and expressibility change from baseline conjunctivocorneal staining with fluorescein and lissamine, tear meniscus height, conjunctival hyperaemia (redness score) and ocular surface disease index questionnaire. Additionally, adverse events will be monitored and documented. ETHICS AND DISSEMINATION: Ethics approval number: IRB(2023)K019.01. The findings will be shared regardless of the effect's direction. TRIAL REGISTRATION NUMBER: NCT05923528.


Assuntos
Síndromes do Olho Seco , Glândulas Tarsais , Humanos , Síndromes do Olho Seco/terapia , Lágrimas , Fluoresceína , Lipídeos , Ensaios Clínicos Controlados Aleatórios como Assunto
20.
Anal Biochem ; 688: 115479, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38342200

RESUMO

Fluorescein itself is a synthetic organic compound and a prominent member of the xanthene dye family. It exhibits strong fluorescence under ultraviolet (UV) or blue light excitation, making it widely used in various applications, including fluorescence microscopy, flow cytometry, immunoassays, and molecular biology techniques. One of the reasons fluorescein derivatives are highly valuable is their tunable fluorescence properties. Through chemical modifications of the fluorescein structure, different functional groups or substituents can be introduce, altering the compound's fluorescence characteristics such as emission wavelength, intensity, and photo stability. This flexibility allows for tailoring of fluorescent probes to specific experimental requirements, enhancing their utility in a range of scientific disciplines. Fluorescein derivatives also possess excellent antimicrobial and antioxidant activity. This review sheds light on the significant impact of fluorescein derivatives as biological active compounds, highlighting their potential in designing new therapeutic agents with antimicrobial properties. Additionally, their role as antioxidants is discussed. A major aspect covered in the review is the application of fluorescein derivatives as powerful cell imaging probes. Their unique fluorescent properties make them valuable tools for visualizing cellular structures and processes, opening up new possibilities for studying cellular dynamics and interactions.


Assuntos
Anti-Infecciosos , Antioxidantes , Fluoresceína , Antioxidantes/farmacologia , Corantes Fluorescentes/química , Microscopia de Fluorescência , Anti-Infecciosos/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...