Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.992
Filtrar
1.
Front Endocrinol (Lausanne) ; 15: 1278504, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38686203

RESUMO

Objective: The objective was to analyze the impact of the uterine artery pulsatility index (PI) on pregnancy outcomes by measuring uterine artery blood flow on the day of endometrial transformation in patients undergoing frozen-thawed embryo transfer (FET). Methods: This was a case-control study. In total, 2,036 patients who underwent FET at the Third Affiliated Hospital of Zhengzhou University from October 2019 to September 2020 were included. The patients were divided into a clinical pregnancy group and a nonclinical pregnancy group according to pregnancy outcome. A multivariate logistic regression model was used to analyze the factors affecting the clinical pregnancy rate. The receiver operating characteristic (ROC) curve was used to determine the optimal mean PI cutoff value of 1.75. After 1:1 propensity score matching (PSM), 562 patients were included. For statistical description and analysis, the patients were divided into two groups: a group with a mean PI > 1.75 and a group with a mean PI ≤ 1.75. Results: The clinical pregnancy group included 1,218 cycles, and the nonclinical pregnancy group included 818 cycles. There were significant differences in female age (P<0.01), infertility type (P=0.04), baseline follicle-stimulating hormone level (P=0.04), anti-Müllerian hormone (AMH) level (P<0.01), antral follicle count (P<0.01), number of transferred embryos (P=0.045) and type of transferred embryo (P<0.01). There was no significant difference in the mean bilateral PI (1.98 ± 0.34 vs. 1.95 ± 0.35, P=0.10). The multivariate analysis results showed that maternal age (AOR=0.95, 95% CI=0.93-0.98, P<0.01), AMH level (AOR=1.00, 95% CI=1.00-1.01, P=0.045), number of transferred embryos (AOR=1.98, 95% CI=1.47-2.70, P<0.01), and type of transferred embryo (AOR=3.10, 95% CI=2.27-4.23, P<0.01) were independent factors influencing the clinical pregnancy rate. The mean PI (AOR=0.85, 95% CI=0.70-1.05; P=0.13) was not an independent factor influencing the clinical pregnancy rate. Participants were divided into two groups according to the mean PI cutoff value of 1.75, and there was no significant difference between the two groups (P > 0.05). Conclusion: In this study, we found that the uterine artery PI on the day of endometrial transformation in patients undergoing FET is not a good predictor of pregnancy outcomes.


Assuntos
Criopreservação , Transferência Embrionária , Endométrio , Resultado da Gravidez , Taxa de Gravidez , Fluxo Pulsátil , Artéria Uterina , Humanos , Feminino , Gravidez , Transferência Embrionária/métodos , Adulto , Artéria Uterina/diagnóstico por imagem , Artéria Uterina/fisiologia , Estudos de Casos e Controles , Fluxo Pulsátil/fisiologia , Endométrio/irrigação sanguínea , Endométrio/diagnóstico por imagem , Fertilização in vitro/métodos , Estudos Retrospectivos
2.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 41(2): 351-359, 2024 Apr 25.
Artigo em Chinês | MEDLINE | ID: mdl-38686417

RESUMO

In this work, we investigated the influence of the bifurcation geometry of the iliac artery on the propagation properties of the pulse wave, and applied software to establish the straight bifurcation and curved bifurcation bi-directional fluid-solid coupling finite element analysis models based on the iliac artery, and compared and analyzed the influence of the bifurcation angle of the blood vessel on the propagation characteristics of the pulse wave. It was found that the bifurcation geometry had a significant effect on the pulse wave propagation in the iliac arteries, and the pressure and velocity pulse wave amplitudes predicted by these two models had a good agreement with that before the vessel bifurcation in a cardiac cycle. The curvilinear bifurcation model predicted the pulse wave amplitude to be lower and the pressure drop to be smaller after the bifurcation, which was more in line with the actual situation of the human body. In addition, the bifurcation point is accompanied by the stress concentration phenomenon in the vessel wall, and there is a transient increase in the velocity pulse waveform amplitude, which was consistent with the fact that the bifurcation site is prone to phenomena such as arterial stenosis and hardening. The preliminary results of this paper will provide some reference for the use of pulse waveforms in the diagnosis of arterial diseases.


Assuntos
Análise de Elementos Finitos , Artéria Ilíaca , Modelos Cardiovasculares , Análise de Onda de Pulso , Humanos , Artéria Ilíaca/fisiologia , Pressão Sanguínea/fisiologia , Fluxo Pulsátil/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Simulação por Computador
3.
Magn Reson Med ; 92(1): 332-345, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38469983

RESUMO

PURPOSE: The delay alternating with nutation for tailored excitation (DANTE)-sampling perfection with application-optimized contrasts (SPACE) sequence facilitates 3D intracranial vessel wall imaging with simultaneous suppression of blood and CSF. However, the achieved image contrast depends closely on the selected sequence parameters, and the clinical use of the sequence is limited in vivo by observed signal variations in the vessel wall, CSF, and blood. This paper introduces a comprehensive DANTE-SPACE simulation framework, with the aim of providing a better understanding of the underlying contrast mechanisms and facilitating improved parameter selection and contrast optimization. METHODS: An extended phase graph formalism was developed for efficient spin ensemble simulation of the DANTE-SPACE sequence. Physiological processes such as pulsatile flow velocity variation, varying flow directions, intravoxel velocity variation, diffusion, and B 1 + $$ {\mathrm{B}}_1^{+} $$ effects were included in the framework to represent the mechanisms behind the achieved signal levels accurately. RESULTS: Intravoxel velocity variation improved temporal stability and robustness against small velocity changes. Time-varying pulsatile velocity variation affected CSF simulations, introducing periods of near-zero velocity and partial rephasing. Inclusion of diffusion effects was found to substantially reduce the CSF signal. Blood flow trajectory variations had minor effects, but B 1 + $$ {\mathrm{B}}_1^{+} $$ differences along the trajectory reduced DANTE efficiency in low- B 1 + $$ {\mathrm{B}}_1^{+} $$ areas. Introducing low-velocity pulsatility of both CSF and vessel wall helped explain the in vivo observed signal heterogeneity in both tissue types. CONCLUSION: The presented simulation framework facilitates a more comprehensive optimization of DANTE-SPACE sequence parameters. Furthermore, the simulation framework helps to explain observed contrasts in acquired data.


Assuntos
Algoritmos , Encéfalo , Simulação por Computador , Imageamento Tridimensional , Humanos , Encéfalo/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Imageamento Tridimensional/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Processamento de Imagem Assistida por Computador/métodos , Fluxo Pulsátil/fisiologia , Circulação Cerebrovascular/fisiologia , Imageamento por Ressonância Magnética/métodos
4.
Int J Cardiol ; 405: 131969, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38490269

RESUMO

BACKGROUND: Functional abnormalities of the ascending aorta (AA) have been mainly reported in young patients who underwent arterial switch operation (ASO) for transposition of the great arteries (TGA). OBJECTIVES: To compare systolic, diastolic brachial and central blood pressures (bSBP, bDBP, cSBP, cDBP), aortic biomechanical parameters, and left ventricular (LV) afterload criteria in adult ASO patients with healthy controls and to assess their relationships with LV remodeling and aortic size. MATERIALS AND METHODS: Forty-one prospectively enrolled patients (16.8 to 35.8 years) and 41 age- and sex-matched healthy volunteers underwent cardiac MRI to assess LV remodeling with simultaneous brachial BP estimation. After MRI, carotid-femoral tonometry was performed to measure pulse wave velocity (cfPWV), cSBP and cDBP for further calculation of pulse pressure (cPP), AA distensibility (AAD), and AA and LV elastance (AAE, LVE). RESULTS: bSBP, bDBP, cSBP,cDBP and cPP were all significantly higher in ASO group than in controls: cSBP (116.5 ± 13.8 vs 106.1 ± 12.0, p < 0.001), cDBP (72.5 ± 6.9 vs 67.1 ± 9.4, p = 0.002), cPP (44.0 ± 12.1 vs 39.1 ± 8.9, p = 0.003) and not related to aortic size. AAD were decreased in ASO patients vs controls (4.70 ± 2.72 vs 6.69 ± 2.16, p < 0.001). LV mass was correlated with bSBP, cSBP, cPP (ρ = 0.48; p < 0.001), while concentric LV remodeling was correlated with AAE (ρ = 0.60, p < 0.001) and LVE (ρ = 0.32, p = 0.04), but not with distensibility. CONCLUSION: Even without reaching arterial hypertension, aortic sBP and PP are increased in the adult TGA population after ASO, altering the pulsatile components of afterload and contributing to LV concentric remodeling.


Assuntos
Transposição das Grandes Artérias , Transposição dos Grandes Vasos , Remodelação Ventricular , Humanos , Transposição dos Grandes Vasos/cirurgia , Transposição dos Grandes Vasos/fisiopatologia , Transposição dos Grandes Vasos/diagnóstico por imagem , Masculino , Feminino , Adulto , Remodelação Ventricular/fisiologia , Adulto Jovem , Estudos Prospectivos , Adolescente , Pressão Arterial/fisiologia , Aorta/diagnóstico por imagem , Aorta/fisiopatologia , Análise de Onda de Pulso , Imagem Cinética por Ressonância Magnética/métodos , Fluxo Pulsátil/fisiologia
5.
J Cardiothorac Vasc Anesth ; 38(6): 1361-1368, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38555215

RESUMO

OBJECTIVES: The aim of this study was to evaluate if the presence of a pulsatile femoral vein pattern is an indicator of venous congestion in the intensive care unit (ICU). DESIGN: Retrospective observational study. SETTING: Three medico-surgical university-affiliated ICUs. PARTICIPANTS: Adult patients who had an ultrasound evaluation at several time points during their ICU stay: at baseline (within 24 hours of admission to ICU), daily during their ICU stay, and within 24 hours before ICU discharge. INTERVENTIONS: At each time point, the hemodynamic, respiratory, and cardiac ultrasound parameters were recorded. The common femoral vein was studied with pulsed-wave Doppler at the level of the femoral trigonum, with high frequency (5-13 MHz) linear array vascular probe and venous vascular mode, in supine patients. MEASUREMENTS AND MAIN RESULTS: One hundred eight patients who underwent 400 ultrasound evaluations (3.7 ± 1 ultrasound evaluations per patient) during their ICU stay were included. Seventy-nine of 108 patients (73%) had a pulsatile femoral vein pattern at least at 1 time point. The multivariable mixed effects logistic regression model demonstrated an association among pulsatile femoral vein pattern, body mass index (OR: 0.91[95% CI 0.85-0.96], p = 0.002), inferior vena cava mean diameter (OR: 2.35 [95% CI 1.18-4.66], p = 0.014), portal vein pulsatility (OR: 2.3 [95% CI 1.2-4.4], p = 0.012), and congestive renal vein flow pattern (OR: 4.02 [95% CI 2.01-8.03], p < 0.001). The results were confirmed by principal component analysis. CONCLUSION: In the ICU, a pulsatile femoral vein pattern is associated with parameters of venous congestion, independently of the patient's volume status, and ventilatory treatment. These results suggest the femoral vein Doppler pulsatility as a parameter of congestion in ICU patients.


Assuntos
Veia Femoral , Unidades de Terapia Intensiva , Fluxo Pulsátil , Humanos , Feminino , Masculino , Estudos Retrospectivos , Veia Femoral/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Fluxo Pulsátil/fisiologia , Hiperemia/diagnóstico por imagem , Hiperemia/fisiopatologia , Adulto , Cuidados Críticos/métodos
6.
Comput Biol Med ; 169: 107788, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38091724

RESUMO

Continuous flow (CF) left ventricular assist devices (LVAD) operate at a constant speed mode, which could result in increased risk of adverse events due to reduced vascular pulsatility. Consequently, pump speed modulation algorithms have been proposed to augment vascular pulsatility. However, the quantitative local hemodynamic effects on the aorta when the pump is operating with speed modulation using different types of CF-LVADs are still under investigation. The computational fluid dynamics (CFD) study was conducted to quantitatively elucidate the hemodynamic effects on a clinical patient-specific aortic model under different speed patterns of CF-LVADs. Pressure distribution, wall shear stress (WSS), time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI), relative residence time (RRT), and velocity were calculated to compare their differences at constant and pulsatile speeds under centrifugal and axial LVAD support. Results showed that pulse pressure on the aorta was significantly larger under pulsatile speed mode than that under constant speed mode for both CF-LVADs, indicating enhanced aorta pulsatility, as well as the higher peak blood flow velocity on some representative slices of aorta. Pulsatile speed modulation enhanced peak WSS compared to constant speed; high TAWSS region appeared near the branch of left common carotid artery and distal aorta regardless of speed modes and CF-LVADs but these regions also had low OSI; RRT was almost the same for all the cases. This study may provide a basis for the scientific and reasonable selection of the pulsatile speed patterns of CF-LVADs for treating heart failure patients.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Hidrodinâmica , Modelos Cardiovasculares , Fluxo Pulsátil/fisiologia , Hemodinâmica/fisiologia
7.
Placenta ; 145: 45-50, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38064937

RESUMO

INTRODUCTION: Fetal growth restriction is known to be related to decreased fetal and placental blood flow. It is not known, however, whether placental size is related to fetal and placental blood flow. We studied the correlations of intrauterine placental volume and placental-fetal-ratio with pulsatility index (PI) in the uterine arteries, fetal middle cerebral artery, and umbilical artery. METHODS: We followed a convenience sample of 104 singleton pregnancies, and we measured placental and fetal volumes using magnetic resonance imaging (MRI) at gestational week 27 and 37 (n = 89). Pulsatility index (PI) was measured using Doppler ultrasound. We calculated cerebroplacental ratio as fetal middle cerebral artery PI/umbilical artery PI and placental-fetal-ratio as placental volume (cm3)/fetal volume (cm3). RESULTS: At gestational week 27, placental volume was negatively correlated with uterine artery PI (r = -0.237, p = 0.015, Pearson's correlation coefficient), and positively correlated with fetal middle cerebral artery PI (r = 0.247, p = 0.012) and cerebroplacental ratio (r = 0.208, p = 0.035). Corresponding correlations for placental-fetal-ratio were -0.273 (p = 0.005), 0.233 (p = 0.018) and 0.183 (p = 0.064). Umbilical artery PI was not correlated with placental volume. At gestational week 37, we found weaker and no significant correlations between placental volume and the pulsatility indices. CONCLUSIONS: Our results suggest that placental size is correlated with placental and fetal blood flow at gestational week 27.


Assuntos
Retardo do Crescimento Fetal , Placenta , Gravidez , Feminino , Humanos , Placenta/irrigação sanguínea , Estudos Prospectivos , Retardo do Crescimento Fetal/diagnóstico por imagem , Circulação Placentária/fisiologia , Artérias Umbilicais , Ultrassonografia Pré-Natal , Ultrassonografia Doppler , Artéria Cerebral Média/fisiologia , Idade Gestacional , Fluxo Pulsátil/fisiologia
8.
Ultrasound Obstet Gynecol ; 63(1): 68-74, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37698356

RESUMO

OBJECTIVE: Effective first-trimester screening for pre-eclampsia (PE) can be achieved using a competing-risks model that combines risk factors from the maternal history with multiples of the median (MoM) values of biomarkers. A new model using artificial intelligence through machine-learning methods has been shown to achieve similar screening performance without the need for conversion of raw data of biomarkers into MoM. This study aimed to investigate whether this model can be used across populations without specific adaptations. METHODS: Previously, a machine-learning model derived with the use of a fully connected neural network for first-trimester prediction of early (< 34 weeks), preterm (< 37 weeks) and all PE was developed and tested in a cohort of pregnant women in the UK. The model was based on maternal risk factors and mean arterial blood pressure (MAP), uterine artery pulsatility index (UtA-PI), placental growth factor (PlGF) and pregnancy-associated plasma protein-A (PAPP-A). In this study, the model was applied to a dataset of 10 110 singleton pregnancies examined in Spain who participated in the first-trimester PE validation (PREVAL) study, in which first-trimester screening for PE was carried out using the Fetal Medicine Foundation (FMF) competing-risks model. The performance of screening was assessed by examining the area under the receiver-operating-characteristics curve (AUC) and detection rate (DR) at a 10% screen-positive rate (SPR). These indices were compared with those derived from the application of the FMF competing-risks model. The performance of screening was poor if no adjustment was made for the analyzer used to measure PlGF, which was different in the UK and Spain. Therefore, adjustment for the analyzer used was performed using simple linear regression. RESULTS: The DRs at 10% SPR for early, preterm and all PE with the machine-learning model were 84.4% (95% CI, 67.2-94.7%), 77.8% (95% CI, 66.4-86.7%) and 55.7% (95% CI, 49.0-62.2%), respectively, with the corresponding AUCs of 0.920 (95% CI, 0.864-0.975), 0.913 (95% CI, 0.882-0.944) and 0.846 (95% CI, 0.820-0.872). This performance was achieved with the use of three of the biomarkers (MAP, UtA-PI and PlGF); inclusion of PAPP-A did not provide significant improvement in DR. The machine-learning model had similar performance to that achieved by the FMF competing-risks model (DR at 10% SPR, 82.7% (95% CI, 69.6-95.8%) for early PE, 72.7% (95% CI, 62.9-82.6%) for preterm PE and 55.1% (95% CI, 48.8-61.4%) for all PE) without requiring specific adaptations to the population. CONCLUSIONS: A machine-learning model for first-trimester prediction of PE based on a neural network provides effective screening for PE that can be applied in different populations. However, before doing so, it is essential to make adjustments for the analyzer used for biochemical testing. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Pré-Eclâmpsia , Recém-Nascido , Gravidez , Feminino , Humanos , Primeiro Trimestre da Gravidez , Pré-Eclâmpsia/epidemiologia , Diagnóstico Pré-Natal/métodos , Proteína Plasmática A Associada à Gravidez , Inteligência Artificial , Pressão Arterial/fisiologia , Fator de Crescimento Placentário , Fluxo Pulsátil/fisiologia , Artéria Uterina , Biomarcadores , Aprendizado de Máquina
9.
Med Biol Eng Comput ; 62(4): 1165-1176, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38155315

RESUMO

To investigate flow conditions in a double-layered carotid artery stent, a bench-top in vitro flow setup including a bifurcation phantom was designed and fabricated. The geometry of the tissue-mimicking phantom was based on healthy individuals. Two identical phantoms were created using 3D-printing techniques and molding with PVA-gel. In one of them, a clinically available CGuard double-layer stent was inserted. Measurements were performed using both continuous and pulsatile flow conditions. Blood flow studies were performed using echoPIV: a novel ultrasound-based technique combined with particle image velocimetry. A maximum deviation of 3% was visible between desired and measured flow patterns. The echoPIV measurements showed promising results on visualization and quantification of blood flow in and downstream the stent. Further research could demonstrate the effects of a double-layered stent on blood flow patterns in a carotid bifurcation in detail.


Assuntos
Artérias Carótidas , Hemodinâmica , Humanos , Artérias Carótidas/fisiologia , Reologia/métodos , Fluxo Pulsátil/fisiologia , Stents , Velocidade do Fluxo Sanguíneo/fisiologia
10.
Biomed Phys Eng Express ; 9(6)2023 10 19.
Artigo em Inglês | MEDLINE | ID: mdl-37820604

RESUMO

In this study, we investigate the impact of aortic stenosis on the hemodynamics of pulsatile blood flow within a 3D aortic model. Employing a non-Newtonian Casson model with a hematocrit of 45%, our study introduces a preliminary hypothesis to simulate blood flow dynamics, incorporating both linear elastic and viscoelastic models to define the mechanical characteristics of the artery. Through simulations conducted with Ansys-Cfx (version 15), we utilize a 2-way fluid-structure interaction (FSI) approach, employing a Lagrangian-Eulerian formulation with second-order accuracy. We explore the influence of stenosis severity on variables including velocity profiles, pressure distribution, shear stress, wall displacement, and changes in the OSI parameter. Our investigation encompasses arteries with both elastic and viscoelastic walls. The key findings that arise from our results highlight the viscoelastic model's demonstration of reduced radial wall displacement when compared to the linear elastic model. Additionally, we observe that elevated arterial stenosis percentages lead to the elongation of vortex length, heightened wall shear stress, and increased slope of velocity profiles downstream of the stenosed region. Furthermore, bulky obstruction of viscoelastic arteries as opposed to elastic, resulted in a maximum 5 percent increase in velocity profile and a 29.6% decrease in radial displacement. The zenith of shear stress occurs concomitantly with the velocity's peak within the stenosed area. Viscoelastic arterial wall shear stress at the stenosis site escalates due to the rapid expansion of the stenosis. The viscoelastic wall, responding with a blend of viscous and elastic characteristics to applied stress, undergoes slight deformation in shape. Following stress reduction, the wall gradually reverts to its original form, thus alleviating some of the applied stress. In contrast, the elastic wall retains its altered shape due to stress preservation within the material. Additionally, we ascertain an augmentation in radial displacement corresponding with increased artery stenosis.


Assuntos
Artérias , Hemodinâmica , Humanos , Constrição Patológica , Hemodinâmica/fisiologia , Fluxo Pulsátil/fisiologia , Viscosidade
12.
J Mech Behav Biomed Mater ; 145: 105994, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37418970

RESUMO

Regulating pulsatile flow is important to achieve optimal separation and mixing and enhanced heat transfer in microfluidic devices, as well as maintaining homeostasis in biological systems. The human aorta, a composite and layered tube made (among others) of elastin and collagen, is an inspiration for researchers who seek an engineering solution for a self-regulation of pulsatile flow. Here, we present a bio-inspired approach showing that fabric-jacketed elastomeric tubes, manufactured using commercially available silicone rubber and knitted textiles, can be used to regulate pulsatile flow. Our tubes are evaluated via incorporation into a mock-circulatory 'flow loop' that replicates the pulsatile fluid flow conditions of an ex-vivo heart perfusion (EVHP) device, a machine used in heart transplants. Pressure waveforms measured near the elastomeric tubing clearly indicated an effective flow regulation. The 'dynamic stiffening' behavior of the tubes during deformation is analyzed quantitatively. Broadly, the fabric jackets allow for the tubes to experience greater magnitudes of pressure and distension without risk of asymmetric aneurysm within the expected operating time of an EVHP. Owing to its highly tunable nature, our design may serve as a basis for tubing systems that require passive self-regulation of pulsatile flow.


Assuntos
Hemodinâmica , Autocontrole , Humanos , Fluxo Pulsátil/fisiologia , Coração , Aorta/fisiologia , Modelos Cardiovasculares
13.
Physiol Rep ; 11(11): e15731, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37269177

RESUMO

Pulsatile hemodynamics analyses provide important information about the ventricular-arterial system which cannot be inferred by standard blood pressure measurements. Pulse wave analysis (PWA), wave separation analysis (WSA), and wave power analysis (WPA) characterize arterial hemodynamics with limited preclinical applications. Integrating these tools into preclinical testing may enhance understanding of disease or therapeutic effects on cardiovascular function. We used a canine rapid ventricular pacing (RVP) heart failure model to: (1) Characterize hemodynamics in response to RVP and (2) assess analyses from flow waveforms synthesized from pressure compared to those derived from measured flow. Female canines (n = 7) were instrumented with thoracic aortic pressure transducers, ventricular pacing leads, and an ascending aortic flow probe. Data were collected at baseline, 1 week, and 1 month after RVP onset. RVP progressively reduced stroke volume (SV), the PWA SV estimator, and WSA and WPA pulsatility and wave reflection indices. Indices derived from synthesized flow exhibited similar directional changes and high concordance with measured flow calculations. Our data demonstrate the value of analytical hemodynamic methods to gain deeper insight into cardiovascular function in preclinical models. These approaches can provide complementary value to standard endpoints in evaluating potential effects of pharmaceutical agents intended for human use.


Assuntos
Insuficiência Cardíaca , Hemodinâmica , Animais , Feminino , Cães , Humanos , Hemodinâmica/fisiologia , Artérias/fisiologia , Aorta , Coração , Simulação por Computador , Pressão Sanguínea/fisiologia , Fluxo Pulsátil/fisiologia , Análise de Onda de Pulso/métodos
14.
Ultrasound Obstet Gynecol ; 61(6): 691-697, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37058400

RESUMO

OBJECTIVES: The mechanism by which aspirin prevents pre-eclampsia is poorly understood, and its effects on biomarkers throughout pregnancy are unknown. We aimed to investigate the effects of aspirin on mean arterial pressure (MAP) and mean uterine artery pulsatility index (UtA-PI) using repeated measures from women at increased risk of preterm pre-eclampsia. METHODS: This was a longitudinal secondary analysis of the Combined Multimarker Screening and Randomized Patient Treatment with Aspirin for Evidence-Based Pre-eclampsia Prevention (ASPRE) trial using repeated measures of MAP and UtA-PI. In the trial, 1620 women at increased risk of preterm pre-eclampsia were identified using the Fetal Medicine Foundation algorithm at 11 + 0 to 13 + 6 weeks, of whom 798 were randomly assigned to receive 150 mg/day aspirin and 822 were assigned to receive placebo daily from 11-14 weeks to 36 weeks of gestation or delivery, whichever came first. MAP and UtA-PI were measured at baseline and follow-up visits at 19-24, 32-34 and 36 weeks of gestation. Generalized additive mixed models with treatment by gestational age interaction terms were used to investigate the effects of aspirin on MAP and UtA-PI trajectories over time. RESULTS: Among 798 participants in the aspirin group and 822 in the placebo group, there were 5951 MAP and 5942 UtA-PI measurements. Trajectories of raw and multiples of the median (MoM) values of MAP did not differ significantly between the two groups (MAP MoM analysis: P-value for treatment by gestational age interaction, 0.340). In contrast, trajectories of raw and MoM values of UtA-PI showed a significantly steeper decline in the aspirin group than in the placebo group, with the difference mainly driven by a more pronounced reduction before 20 weeks of gestation (UtA-PI MoM analysis: P-value for treatment by gestational age interaction, 0.006). CONCLUSIONS: In women at increased risk of preterm pre-eclampsia, 150 mg/day aspirin initiated in the first trimester does not affect MAP but is associated with a significant decrease in mean UtA-PI, particularly before 20 weeks of gestation. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Aspirina , Pré-Eclâmpsia , Gravidez , Recém-Nascido , Feminino , Humanos , Aspirina/farmacologia , Aspirina/uso terapêutico , Pré-Eclâmpsia/tratamento farmacológico , Pré-Eclâmpsia/prevenção & controle , Pressão Arterial/fisiologia , Artéria Uterina , Fator de Crescimento Placentário , Primeiro Trimestre da Gravidez , Biomarcadores , Fluxo Pulsátil/fisiologia
15.
J Matern Fetal Neonatal Med ; 36(1): 2183759, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36889747

RESUMO

BACKGROUND: Regular and supervised exercise during pregnancy is worldwide recommended due to its proven benefits, but, during exercise, maternal blood flow is redirected from the viscera to the muscles and how fetal wellbeing may be affected by this redistribution is still not well known. OBJECTIVE: To analyze the longitudinal effect of a supervised moderate physical exercise program during pregnancy on uteroplacental and fetal Doppler parameters. METHODS: This is a planned secondary analysis of an randomized controlled trial (RCT), performed at Hospital Universitario de Torrejón, Madrid, Spain, including 124 women randomized from 12+0 to 15+6 weeks of gestation to exercise vs. control group. Fetal umbilical artery (UA), middle cerebral artery, and uterine artery pulsatility index (PI), were longitudinally collected by Doppler ultrasound assessment throughout gestation, and derived cerebroplacental ratio (normalized by z-score), and maternal mean PI in the uterine arteries (normalized by multiplies of the median). Obstetric appointments were scheduled at 12 (baseline, 12+0 to 13+5), 20 (19+0 to 24+2), 28 (26+3 to 31+3) and 35 weeks (32+6 to 38+6) of gestation. Generalized estimating equations were adjusted to assess longitudinal changes in the Doppler measurements according to the randomization group. RESULTS: No significant differences in the fetal or maternal Doppler measurements were found at any of the different checkup time points studied. The only variable that consistently affected the Doppler standardized values was gestational age at the time of assessment. The evolution of the UA PI z-score during the pregnancy was different in the two study groups, with a higher z-score in the exercise group at 20 weeks and a subsequent decrease until delivery while in the control group it remained stable at around zero. CONCLUSIONS: A regular supervised moderate exercise program during pregnancy does not deteriorate fetal or maternal ultrasound Doppler parameters along the pregnancy, suggesting that the fetal well-being is not compromised by the exercise intervention. Fetal UA PI z-score decreases during pregnancy to lower levels in the exercise group compared with the control group.


Assuntos
Feto , Ultrassonografia Pré-Natal , Gravidez , Feminino , Humanos , Feto/diagnóstico por imagem , Feto/irrigação sanguínea , Cuidado Pré-Natal , Idade Gestacional , Artéria Cerebral Média/diagnóstico por imagem , Ultrassonografia Doppler , Artérias Umbilicais/diagnóstico por imagem , Artérias Umbilicais/fisiologia , Fluxo Pulsátil/fisiologia
16.
Int J Numer Method Biomed Eng ; 39(5): e3695, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36914373

RESUMO

Numerical simulations of pulsatile blood flow in an aortic coarctation require the use of turbulence modeling. This paper considers three models from the class of large eddy simulation (LES) models (Smagorinsky, Vreman, σ -model) and one model from the class of variational multiscale models (residual-based) within a finite element framework. The influence of these models on the estimation of clinically relevant biomarkers used to assess the degree of severity of the pathological condition (pressure difference, secondary flow degree, normalized flow displacement, wall shear stress) is investigated in detail. The simulations show that most methods are consistent in terms of severity indicators such as pressure difference and stenotic velocity. Moreover, using second-order velocity finite elements, different turbulence models might lead to considerably different results concerning other clinically relevant quantities such as wall shear stresses. These differences may be attributed to differences in numerical dissipation introduced by the turbulence models.


Assuntos
Coartação Aórtica , Humanos , Hemodinâmica , Simulação por Computador , Constrição Patológica , Fluxo Pulsátil/fisiologia , Modelos Cardiovasculares , Velocidade do Fluxo Sanguíneo , Estresse Mecânico
17.
ASAIO J ; 69(5): e167-e180, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36976324

RESUMO

Refractory cardiogenic shock is increasingly being treated with veno-arterial extracorporeal membrane oxygenation (V-A ECMO), without definitive proof of improved clinical outcomes. Recently, pulsatile V-A ECMO has been developed to address some of the shortcomings of contemporary continuous-flow devices. To describe current pulsatile V-A ECMO studies, we conducted a systematic review of all preclinical studies in this area. We adhered to PRISMA and Cochrane guidelines for conducting systematic reviews. The literature search was performed using Science Direct, Web of Science, Scopus, and PubMed databases. All preclinical experimental studies investigating pulsatile V-A ECMO and published before July 26, 2022 were included. We extracted data relating to the 1) ECMO circuits, 2) pulsatile blood flow conditions, 3) key study outcomes, and 4) other relevant experimental conditions. Forty-five manuscripts of pulsatile V-A ECMO were included in this review detailing 26 in vitro , two in silico , and 17 in vivo experiments. Hemodynamic energy production was the most investigated outcome (69%). A total of 53% of studies used a diagonal pump to achieve pulsatile flow. Most literature on pulsatile V-A ECMO focuses on hemodynamic energy production, whereas its potential clinical effects such as favorable heart and brain function, end-organ microcirculation, and decreased inflammation remain inconclusive and limited.


Assuntos
Oxigenação por Membrana Extracorpórea , Humanos , Choque Cardiogênico/terapia , Hemodinâmica/fisiologia , Fluxo Pulsátil/fisiologia , Inflamação
18.
J Surg Res ; 283: 1145-1153, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36915006

RESUMO

INTRODUCTION: Multiple perfusion systems have been investigated on vascularized composite allografts, with various temperatures and different preservation solutions, most using continuous flow (CF). However, physiological flow is pulsatile and provides better outcomes in kidney and lung ex vivo perfusions. The objective of this pilot study is to compare pulsatile flow (PF) with CF in our 24-h subnormothermic machine perfusion protocol for swine hindlimbs. METHODS: Partial hindlimbs were harvested from Yorkshire pigs and perfused with a modified Steen solution at 21°C for 24 h either with CF (n = 3) or with pulsatile flow (PF) at 60 beats/min (n = 3). Perfusion parameters, endothelial markers, and muscle biopsies were assessed at different timepoints. RESULTS: Overall, lactate levels were significantly lower in the PF group (P = 0.001). Glucose uptake and potassium concentration were similar in both groups throughout perfusion. Total nitric oxide levels were significantly higher in the PF group throughout perfusion (P = 0.032). Nitric oxide/endothelin-1 ratio also tends to be higher in the PF group, reflecting a potentially better vasoconductivity with PF, although not reaching statistical significance (P = 0.095). Arterial resistances were higher in the PF group (P < 0.001). Histological assessment did not show significant difference in muscular injury between the two groups. Weight increased quicker in the CF group but reached similar values with the PF after 24 h. CONCLUSIONS: This pilot study suggests that PF may provide superior preservation of vascularized composite allografts when perfused for 24 h at subnormothermic temperatures, with potential improvement in endothelial function and decreased ischemic injury.


Assuntos
Aloenxertos Compostos , Preservação de Órgãos , Suínos , Animais , Projetos Piloto , Preservação de Órgãos/métodos , Fluxo Pulsátil/fisiologia , Óxido Nítrico , Perfusão/métodos
19.
Comput Biol Med ; 157: 106767, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36933414

RESUMO

Erythrocyte aggregation (EA) is a highly dynamic, vital phenomenon to interpreting human hemorheology, which would be helpful for the diagnosis and prediction of circulatory anomalies. Previous studies of EA on erythrocyte migration and the Fåhraeus Effect are based on the microvasculature. They have not considered the natural pulsatility of the blood flow or large vessels and mainly focused on shear rate along radial direction under steady flow to comprehend the dynamic properties of EA. To our knowledge, the rheological characteristics of non-Newtonian fluids under Womersley flow have not reflected the spatiotemporal behaviors of EA or the distribution of erythrocyte dynamics (ED). Hence, it needs to interpret the ED affected by temporal and spatial flow variation to understand the effect of EA under Womersley flow. Here, we demonstrated the numerically simulated ED to decipher EA's rheological role in axial shear rate under Womersley flow. In the present study, the temporal and spatial variations of the local EA were found to mainly depend on the axial shear rate under Womersley flow in an elastic vessel, while mean EA decreased with radial shear rate. The localized distribution of parabolic or M-shape clustered EA was found in a range of the axial shear rate profile (-15 to 15s-1) at low radial shear rates during a pulsatile cycle. However, the linear formation of rouleaux was realized without local clusters in a rigid wall where the axial shear rate is zero. In vivo, the axial shear rate is usually considered insignificant, especially in straight arteries, but it has a great impact on the disturbed blood flow due to the geometrical properties, such as bifurcations, stenosis, aneurysm, and the cyclic variation of pressure. Our findings regarding axial shear rate provide new insight into the local dynamic distribution of EA, which is a critical player in blood viscosity. These will provide a basis for the computer-aided diagnosis of hemodynamic-based cardiovascular diseases by decreasing the uncertainty in the pulsatile flow calculation.


Assuntos
Agregação Eritrocítica , Modelos Cardiovasculares , Humanos , Agregação Eritrocítica/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Hemorreologia , Fluxo Pulsátil/fisiologia , Artérias/fisiologia , Simulação por Computador , Estresse Mecânico
20.
ASAIO J ; 69(5): e192-e198, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36913553

RESUMO

Mechanical heart valve (MHV) prostheses present a risk of thromboembolic complications despite antithrombotic therapy. Further steps in the development of more hemocompatible MHVs and new anticoagulants are impeded due to the lack of adequate in-vitro models. With the development of a novel in-vitro model (MarioHeart), a pulsatile flow similar to the arterial circulation is emulated. The MarioHeart design owns unique features as 1) a single MHV within a torus with low surface/volume ratio, 2) a closed loop system, and 3) a dedicated external control system driving the oscillating rotational motion of the torus. For verification purposes, a blood analog fluid seeded with particles was used to assess fluid velocity and flow rate using a speckle tracking method on high-speed video recordings of the rotating model. The flow rate resembled the physiological flow rate in the aortic root, in both shape and amplitude. Additional in-vitro runs with porcine blood showed thrombi on the MHV associated with the suture ring, which is similar to the in-vivo situation. MarioHeart is a simple design which induces well-defined fluid dynamics resulting in physiologically nonturbulent flow without stasis of the blood. MarioHeart seems suitable for testing the thrombogenicity of MHVs and the potential of new anticoagulants.


Assuntos
Próteses Valvulares Cardíacas , Animais , Suínos , Velocidade do Fluxo Sanguíneo/fisiologia , Desenho de Prótese , Fluxo Pulsátil/fisiologia , Movimento (Física) , Modelos Cardiovasculares , Valva Aórtica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...